ADC Telecommunications DNXSMR1A Digivance® NXD SMR 900 MHz System User Manual 75210
ADC Telecommunications Inc Digivance® NXD SMR 900 MHz System 75210
Contents
- 1. User Manual 1
- 2. User Manual 2
- 3. User Manual 3
- 4. User Manual 4
User Manual 2
ADCP-75-210 • Issue 1 • November 2006 1.6.2 Fiber Optic Cable Entry A nylon connector is provided on the rear of the RAN cabinet for routing a fiber optic cable into the cabinet. The cord connector provides cable strain relief and a watertight seal at the fiber optic cable entry point. As the connector nut is tightened, a soft neoprene bushing compresses to tightly grip the cable without applying excessive force to the fibers. The connector accommodates cables of a diameter in the range .38 to .50 inches (.97 to 1.27 cm). Note: If the installer has a larger cable, the manufacturer (Hubbell Inc.) makes bushings that fit this connector in the following size ranges: .500-.625, .625-.750, .750-.875, .8751.00, 1.00-1.125 inches. In a typical installation, the connectorized end of a multi-fiber OSP cable is routed into the cabinet through the cord connector and the individual fibers are connected to the optical transceiver on the Synchronous Interface Card (SIF). Excess slack is stored inside the cabinet. The stub end of the cable is routed to an external splice enclosure (not provided) for splicing to the outside plant fiber optic cable. 1.6.3 Antenna Cable Connections Five N-type plugs are provided on the rear of the RAN cabinet for connecting the antenna coaxial cables. On the inside of the cabinet, coaxial jumper cables (included with the cabinet) are used for connecting to the antenna port on the appropriate multiplexer. 1.6.4 AC Power Wiring Entry and Grounding The NXD RAN uses 240 VAC power. A one inch (2.54 cm), 90 degree rigid elbow conduit fitting is provided on the rear of the cabinet. The conduit should be routed to an external junction box (not provided). It is suggested that an external AC outlet (not provided) be installed near the cabinet to power test equipment and power tools. The AC source should supply 50/60 Hz, single-phase power through a circuit breaker rated at 20 Amps. 1.6.5 Ventilation Ventilation openings are provided in the front door of the RAN cabinet to permit entry of air for cooling. A filter removes dirt particles so that only clean air enters the cabinet. The heated air exits the cabinet through the rear side. The four PAAs are each equipped with three cooling fans that pull air through the module and exhaust it to the rear of the cabinet. A fan assembly at the top of the RAN chassis forces the air out the rear side of the cabinet. Page 9 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1.7 RAN Chassis and Electronic Modules The RAN chassis, shown in Figure 6, is a standard Compact PCI (cPCI) shelf capable of housing 21 industry standard cPCI circuit cards (called “electronic modules” in this manual). The backplane supports the basic cPCI functions and it has been extended to allow the routing of DIFTM, reference clocks and I2C signals between I2C modules. The RAN chassis also houses cooling fans within the Fan Access Panel on the top of the chassis. Table 3 identifies the electronic modules using the callout reference numbers from Figure 6. 10 21282-A Figure 6. RAN Chassis Table 3. RAN Chassis Electronic Modules REF # MODULE NAME FOR DETAILS REFER TO cPCI Power Supplies Section 1.7.1 on Page 12 Central Processing Unit (CPU) Section 1.7.2 on Page 13 System Interface (STF2) Section 1.7.3 on Page 14 Synchronous Interface (SIF) Section 1.7.4 on Page 15 Page 10 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 3. RAN Chassis Electronic Modules REF # MODULE NAME FOR DETAILS REFER TO Small Form-Factor Pluggable Optical Transceiver (SFP) Section 1.7.5 on Page 17 RAN Down Converter (RDC or RDC2) Section 1.7.6 on Page 17 RAN Up Converter (RUC2.X or RUC3) Section 1.7.7 on Page 19 800 MHz Multi-Coupler Section 1.7.9 on Page 20 1900 MHz Multi-Coupler Section 1.7.10 on Page 22 10 Fan Access Panel Section 1.7.8 on Page 20 Figure 7 is a schematic showing the data flow in the RAN chassis. As shown, data flows in two directions, from the Hub through the RAN to the antenna, and from the antenna through the RAN back to the Hub. In each direction, data conversion occurs, with optical data “upconverted” to RF data in the up direction in the schematic, and RF data “downconverted” to optical data in the down direction. In an up direction, the RUC module converts Digitized Intermediate Frequency (DIF) data into PCS, Cellular, and SMR frequency RF bands. The RF signals are amplified and then transmitted from the RF antenna. In the down direction, the RDC module converts PCS, Cellular, and SMR frequency bands into DIF data. The overall series of events is managed by the CPU using an Ethernet connection to the chassis backplane. MB ANT 1900-P 1900-D 800-P 800-D MPLX Pri Div Pri 1900 MUL RAN MCPA 800 MUL RF RF Div Pri Div RUC RF RAN DIF = Radio Access Node = Digital Intermediate Frequency SIF = Synchronous Interface RUC = RAN Up Converter MCPA = Munti-Carrier Power Amplifier MPLX = Multi-plexer/Combiner MB ANT = Multi Band Antenna MUL = Multi-Coupler RDC = RAN Down Converter RDC DIF DIF DIF Ethernet SIF Fiber CPU Fiber 21294-A HUB Figure 7. RAN Chassis Schematic Page 11 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1.7.1 cPCI Power Supply Modules The Compact PCI (cPCI) Power Supply Modules provide +/-12V, 5V, and 3.3V DC power to the cPCI backplane for use by the cPCI electronic modules. Each RAN requires one power supply module. Two modules can be used to provide redundancy if desired. These modules are hot swappable. Figure 8 shows the cPCI Power Supply Module faceplate. Table 4 describes the faceplate components called out in the figure. POWER GOOD LED FAULT LED 21240-A Figure 8. cPCI Power Supply Module Faceplate CPU Table 4. cPCI Power Supply Module Faceplate Ref # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION PWR GOOD Single-color LED (green) Power Good. Turns green when module has power FAULT Single-color LED (red) Fault. Turns red when module has insufficient power to perform its function Page 12 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1.7.2 Central Processing Unit (CPU) Module The Central Processing Unit (CPU) Module is a cPCI-based, single-board x86 computer with disk running on a Linux operating system. Each RAN chassis has one CPU module. The CPU runs a process management program that manages all RAN hardware including RF and digital equipment. The program also manages RF signal gain and monitors signal presence and quality. Figure 9 shows the CPU module faceplate. Table 5 describes the faceplate components called out in the figure. VIDEO CONNECTOR ETHERNET CONNECTOR ACTICITY LEDs COM 1 CONNECTOR STATUS LEDs RESET BUTTON UNIVERSAL SERIAL BUS CONNECTOR 21251-A Figure 9. CPU Module Faceplate CPU Table 5. CPU Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION USB1 USB connector Front panel input/output for USB connectivity COM 1 RJ-11C connector Front panel interface for COM1 (Unmarked) Status LEDs LED 1 is POST (red on start-up, turns green on successful completion of start-up self test); LED 2 & 3 are undefined; LED 4 (blinking green) indicates disk or flash memory activitity Page 13 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 5. CPU Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION RST Recessed switch Reset. Used to manually reset the CPU POST Single-color LEDs (yellow) Post. Top four LEDs give status of CPU during initial boot process; bottom four give board operation status ENET RJ-45 connector with single-color LEDs (green and yellow) Ethernet. 10 BaseT. Connects to RJ-45 connector on SIF module (10BT port) using cable 1001478P001. Connection status (green) and 100 BT (yellow) VIDEO 15-PIN VGA connector Video. Not used by Digivance system 1.7.3 System Interface (STF2) Module The System Interface (STF2) Module is a cPCI electronic module that provides the CPU and other electronic modules with the ability to communicate with one another using the four I2C buses on the cPCI backplane. One STF2 is used per RAN. The STF2 also has the GPS antenna input port located in the center of the module faceplate. STF2 modules are specified according to the number of qualifying communications devices being utilized. Table 6 describes the module faceplate components. Figure 10 shows the location of the faceplate components. Table 6. System Interface Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION RST Recessed switch Reset. Used to halt operation of the CPU operating system. A power ON reset is required to restart the CPU STATUS 1 Single-color LED (yellow) Reserved for future use. Indicator turns yellow when the CPU is not installed or has malfunctioned STATUS 2 Single-color LED (yellow) Reserved for future use. Indicator turns yellow when the CPU is not installed or has malfunctioned STATUS GPS Single-color LED (green) Indicator showing that 1PPS signal is available. Led toggles once per second (RAN only) DA RJ-45 connector Door Alarm. Input using cable 1001474P001; small LED on this connector lights (red) when door is open GPS RJ-45 connector Not used RECT RJ-45 connector Rectifier. Communications to rectifier using cable 1001476P001 (Unmarked) Single-color LED (red) I2C Error LEDs. One on each I2C RJ-45 connector. Indicator turns red when there is no response on port (Unmarked) Single-color LED (green) I2C Comm LEDs. One on each I2C RJ-45 connector. Indicator turns green when an I2C message sent on the port 10 FLT Single-color LED (red) Fault. Indicator turns red when module has failed or upon startup until the module has completed initialization Page 14 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 6. System Interface Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION 11 HS Single-color LED (blue) Not used 12 PWR Single-color LED (green) Power. Indicator turns green when module has power 13 I2C A-D RJ-45 connectors I2C (Bus). Connectors to I2C buses 14 ANT SMA connector Antenna. Input for GPS antenna signal 15 TLA RJ-45 connector Tower Light Alarm (unused) RESET SWITCH 15 GPS LED TOWER LIGHT ALARM CONNECTOR GPS ANTENNA 14 CONNECTOR (RAN ONLY) 13 I2C CONNECTOR 12 POWER LED STATUS LED 1 STATUS LED 2 DOOR ALARM CONNECTOR GPS COMMS CONNECTOR RECTIFIER COMMS CONNECTOR I2C ERROR LED I2C COMM LED FAULT LED 10 HOT SWAP LED 11 21253-A Figure 10. System Interface Module Faceplate 1.7.4 Synchronous Interface (SIF) Module The Synchronous Interface (SIF) Module provides the optical interface between the Hub and the RAN. This interface provides for exchange of digitized RF signal information and 10BaseT Ethernet command and control information. Each RAN can have up to two SIFs, each handling two bands with diversity receive paths. Page 15 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 The SIF module is equipped with a small form-factor pluggable optical transceiver (SFP) module. (For more information on the SFP, see Section 1.7.5.) Figure 11 shows the SIF module faceplate. Table 7 describes the faceplate components. DIF INPUT LED 1-4 OPTICAL INPUT LED OPTICAL OUTPUT LED SFP FIBER OPTIC CONNECTOR DIF OUTPUT LED 1-4 ETHERNET CONNECTOR FAULT LED HOT SWAP LED POWER LED 21238-A Figure 11. Synchronous Interface Module Faceplate Table 7. Synchronous Interface Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION IN 1-4 Tri-color LED (green/yellow/red) In. Indicates if DIF input is not enabled (off), good (green), degraded (yellow), clock issue (blinking), or no DIF tone lock or unused channel (red) OUT 1-4 Tri-color LED (green/yellow/red) Out. Indicates if DIF output is not enabled (off), good (green), degraded (yellow), clock issue (blinking), or bad data on output of unused channel (red) 10BT RJ-45 connector 10BaseT (Ethernet). Communications between SIF and CPU using cable 1001478P001 HS Blue LED Not used PWR Green LED Power. Lights when module has power FLT Red LED Fault. Lights when module has failed and during start-up until module is initialized Page 16 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 7. Synchronous Interface Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION F/O Dual-LC connectors Fiber/Optics. Optics connector on SFP optical transceiver OP IN Tri-color LED (green/yellow/red) Optical In. Indicates input status of the SFP interface: not enabled (off), good (green), degraded (yellow), or bad output signals (red) OP OUT Tri-color LED (green/yellow/red) Optical Out. Indicates output status of SFP interface: not enabled (off), good (green), degraded (yellow), or bad framing, bad parity, no signal, or no signal lock (red) 1.7.5 Small Form-Factor Pluggable (SFP) Optical Transceiver The Small Form-Factor Pluggable (SFP) Optical Transceiver, located on the SIF module and shown in Figure 12, provides the optical interface between the Hub equipment and the RAN hardware. The SFP has a laser transmitter and an optical receive detector. The Digivance NXD system uses industry standard SFP optics which offer a number of configuration options depending on the requirements of the project. The SFP modules are available separately and may or may not be installed in the SIF depending on the configuration ordered. The SFP module is specified as up to two per RAN and is able to support two bands with receive diversity. The standard SFP module has an optical budget of 9 dB. The SFP module is factory and field replaceable with optical transceivers having extended optical budgets up to 26 dB or Coarse Wave-Division Multiplexing (CWDM) optical wavelengths. 21316-A Figure 12. Small Form-Factor Optical Transceiver 1.7.6 RAN Down Converter (RDC or RDC2) Module The RAN Down Converter (RDC or RDC2) Module is a cPCI electronic module housing a dual-diversity wideband RF receiver. This module takes PCS, Cellular, SMR A, and SMR B signals from a primary and secondary antenna (via the appropriate multicoupler) and converts the signals to Digitized Intermediate Frequency (DIF). Page 17 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 This module also provides a CW test tone for use in reverse continuity testing. The RF signals are input into the module by way of coax cables terminated with SMA connectors on the faceplate (at the ports labeled PRI IN and DIV IN). Figure 13 shows the module faceplate. Table 8 describes the module faceplate components called out in the figure. PRIMARY IN DIVERSITY IN FAULT LED POWER LED 21236-A Figure 13. RAN Down Converter Module Faceplate Table 8. RAN Down Converter Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION PRI IN SMA connector Primary In. Receives RF primary output from either C/PMCPLR or P/MCPLR module. Connection is made using cable 1955000P081 DIV IN SMA connector Diversity In. Receives RF diversity output from either C/ PMCPLR or P/MCPLR module. Connection is made using cable 1955000P081 FLT Red LED Fault. Lights when module has failed and during start-up until module has initialized; blinks after module receives a system clock and is awaiting initialization PWR Green LED Power. Lights when module has power Page 18 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1.7.7 RAN Up Converter (RUC2.X or RUC3) Module The RAN Up Converter (RUC2.X or RUC3) Module is a cPCI electronic module that takes Digitized Intermediate Frequency (DIF) signals from a DIF signal generated by the SIF and converts the signals to RF (PCS, Cellular, SMR A, and SMR B frequency bands). Each module supports two simultaneous bands via wideband outputs. The RUC also provides clocking for its neighboring RDC. For module faceplate and callouts, see Figure 14 and Table 9. COM 1/3 COM 2/4 CHANNEL 1/3 OUT PA CNTL 1/3 PA CNTL 2/4 CHANNEL 2/4 OUT FAULT LED POWER LED 21234-A Figure 14. RAN Up Converter Module Faceplate Table 9. RAN Up Converter Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION CH 1/3 OUT SMA connector Channel 1/3 Out* COM 1/3 Yellow LED COM Port 1/3. Turns yellow when DIF is locked to SIF channel 1 or 3* COM 2/4 Yellow LED COM Port 2/4. Turns yellow when DIF is locked to SIF channel 2 or 4* PA CNTL 1/3 I2C flatpack connector PA Control Channel 1 or 3. Outputs control data to the PIC card on the PAA for the channel being provided (using cable 1955000P079)* Page 19 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 9. RAN Up Converter Module Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION PA CNTL 2/4 I2C flatpack connector PA Control Channel 2 or 4. Outputs control data to the PIC card on the PAA for the channel being provided (using cable 1955000P079)* FLT Red LED Fault. Turns red when the module has failed. Indicator is lit during start-up until module has initialized. Indicator will blink after module receives system clock and is awaiting initialization PWR Green LED Power. Turns green when module has power CH 2/4 OUT SMA connector Channel 2 or 4 OUT* * An RUC in slot A2 will connect to PAAs 1 and 2. An RUC in slot A5 will connect to PAAs 3 and 4. Therefore, the RUC front panel indicators of 1/3 and 2/4 will map to PAAs 1 and 2 connections in slot A2 and PAA 3 and 4 connections in slot A5. 1.7.8 Fan Access Panel The Fan Access Panel, shown in Figure 15, has a hinged front panel that swings down providing access to the two fans cooling the RAN chassis. These fans are user-replaceable. This panel has labels identifying the electronic modules located in the cPCI shelf below the panel. LABELS FOR CPCI ELECTRONIC MODULES 21318-A Figure 15. Fan Access Panel 1.7.9 800 MHz Multicoupler (C/MCPLR) The 800 MHz (C/MCPLR) Module is a cPCI electronic module that houses the dual-diversity, receive unit for the 800 MHz bands. This module interfaces to the multiplexer system and contains the front end low noise amplifiers for the reverse path. The module has six outputs (Cell bands A, B, and 800 MHz, with diversity). Figure 16 shows the location of the faceplate components. Table 10 describes the faceplate components. Page 20 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 10. C/MCPLR Modules Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION P IN SMA connector Primary In. Receives RF primary reverse path input from primary antenna D IN SMA connector Diversity In. Receives RF diversity reverse path input from secondary antenna P OUT SMA connectors Primary Out. 3 primary outputs (Cell bands A, B, and SMR-A). Each output being used connects to one RDC electronic module, either in the same RAN or in the extension RAN if present. Connection is made using cable 1955000P081 D OUT SMA connectors Diversity Out. 3 diversity outputs (Cell bands A, B, and SMR-A). Each output being used connects to one RDC electronic module, either in the same RAN or in the extension RAN if present. Connection is made using cable 1955000P081 FLT Red LED Fault. Lights when module has failed and during start-up until module has initialized PWR Green LED Power. Lights when module has power PRIMARY IN CONNECTOR PRIMARY OUT CONNECTORS DIVERSITY IN CONNECTOR DIVERSITY OUT CONNECTORS FAULT LED POWER LED 21242-A Figure 16. C/MCPLR Module Faceplate Page 21 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1.7.10 1900 MHz Multicoupler (P/MCPLR) The 1900 MHz (P/MCPLR) Module is a cPCI electronic module that houses the dual-diversity, receive unit for the PCS band. This module interfaces to the multiplexer system and contains the front end low noise amplifiers for the reverse path. The PCS band has 12 outputs (bands A-F, with diversity). Figure 17 shows the location of the faceplate components. Table 11 describes the module faceplate components. DIVERSITY OUT CONNECTORS DIVERSITY IN CONNECTOR PRIMARY IN CONNECTOR PRIMARY OUT CONNECTORS FAULT LED POWER LED 21245-A Figure 17. P/MCPLR Modules Faceplates Table 11. P/MCPLR Modules Faceplate Components REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION P IN SMA connector Primary In. Receives RF primary reverse path input from primary antenna D IN SMA connector Diversity In. Receives RF diversity reverse path input from secondary antenna P OUT SMA connectors Primary Out. 6 primary outputs (bands A-F); each output being used connects to one RDC module, in either same RAN or extension RAN if present. Connection is made using cable 1955000P081 Page 22 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 11. P/MCPLR Modules Faceplate Components REF # 1.8 DESIGNATION DEVICE FUNCTIONAL DESCRIPTION D OUT SMA connectors Diversity Out. 6 diversity outputs (bands A-F); each output being used connects on one RDC module, in either same RAN or extension RAN if present. Connection is made using cable 1955000P081 FLT Red LED Fault. Lights when module has failed and during start-up until module has initialized PWR Green LED Power. Lights when module has power Rectifier Shelf The Rectifier Shelf, shown in Figure 18, is a chassis/backplane device that contains rectifier modules and a Low Voltage Disconnect (LVD) unit. The shelf interconnects the rectifier modules and LVD unit, and provides an interface to external connectors. Typically, the rectifier shelf contains two rectifier modules. The center panel on the shelf can be removed to add a third rectifier, providing N+ redundancy as more equipment is added to the RAN chassis. LOW VOLTAGE DISCONNECT (LVD) UNIT RECTIFIER 21319-A AC OK LED DC OK LED OVER VOLTAGE PROTECTION LED OVER TEMPERATURE PROTECTION LED Figure 18. Rectifier Shelf 1.8.1 Rectifier Module The rectifier module converts 240 VAC prime power into -48 VDC for use within the RAN. Each rectifier has four LEDs, shown in Figure 18 and described in Table 12. The rectifiers are controlled by the LVD unit under command of the STF2 module. Page 23 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 12. Rectifier Indicators REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION (Unmarked) Green LED AC OK. Lights when AC power is present (Unmarked) Green LED DC OK. Lights when rectifier is limiting current (Unmarked) Red LED Over Voltage Protection. Lights when rectifier has failed (Unmarked) Red LED Over Temperature Protection. Lights when over temperature compensation circuit is active 1.8.2 Low Voltage Disconnect (LVD) Unit The Low Voltage Disconnect (LVD) Unit (Figure 19) disconnects power automatically when the RAN voltage falls below a specified minimum. The LVD unit also manages the backup batteries (extended or glitch). OK LED MAJOR FAULT LED MINOR FAULT LED LVD ON LED 21334-A Figure 19. Low Voltage Disconnect Unit Table 13. LVD Indicators REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION OK Green LED Okay. Lights when power system is functioning correctly MAJ Red LED Major Fault. Lights when a major fault exists MIN Yellow LED Minor Fault. Lights when a minor fault exists (Unmarked) 9-pin connector Connector for cable 1001476P001 to the RECT (RJ45 connector) port on the STF module LVD Red LED Low Voltage Disconnect. Lights when switch has closed due to low voltage DISC Switch Disconnect. Pressing this switch disconnects the backup batteries Page 24 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1.9 Power Amplifier Assembly The Power Amplifier Assembly (PAA) is an electronic device that amplifies RF signals in the forward path just before they are transmitted to the RAN antenna. Up to four PAAs may be mounted in the RAN, each providing one band. Each PAA consists of a Power Amplifier (PA), a control board called the PA Interface Controller (PIC), and a cooling system. The PA is multichannel. Different units are used for PCS, Cellular, and SMR 800 bands. The PIC interfaces to the discrete signals of the PA. The PIC also provides DC power to the PA by converting from -48 VDC to +12 VDC or +28 VDC depending upon which PA is being used. Each PA has its own PIC. The PIC is managed is managed by the CPU over an I2C connection through its corresponding RUC. The cooling system consists of a heat sink and three fans that provide cooling for the PA by blowing external air across the heat sink. The fans are softwarecontrolled. The PIC module monitors the tachometer outputs of the fan. Figure 20 shows the PA assembly connection points and indicators. Table 14 describes the items called out in the figure. RF IN 48V PWR 12C 21276-A PIC LED INDICATORS DC_ IN DC_ FAULT DC_ OUT POWER AMPLIFIER RF OUT Figure 20. Power Amplifier Assembly Page 25 ADCP-75-210 • Issue 1 • November 2006 Table 14. PAA Connection Points and Indicators REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION DC_IN Green LED DC In. Lighted when PIC has -48 VDC input PA_FAULT Red LED PA Fault. Lighted when PA has failed DC_OUT Green LED DC Out. Lighted when PIC has +28 VDC output I2C RJ-45 connector (J1) I2C (Bus). Connection to RUC module P/A CNTRL using cable 1001475P001 48V PWR Positronic 3-pin connector (J2) 48 Volt DC Power. Input to PIC for -48 VDC using PIC power harness 1001471P001 RF OUT SMA connector RF Out. Output of PA for cable 1955000P080 to one of the four plexers (depending on band), connector port TX (Unmarked) Power Amplifier Power amplifier (see description on preceding page) RF IN SMA connector RF In. Input from RUC for cable 19559999P079 1.10 Multiplexer System The NXD RAN multiplexer system consists of four units that interface to the antenna, PAs, and multicouplers. There are four types found in found in every RAN: • Quadplexer Primary (PCS Bands A, B, F), interfaces to PCS primary antenna; • Quadplexer Diversity (PCS Bands D, E, C), interfaces to PCS diversity antenna; • Triplexer Primary (Cellular Band B, SMR800 band), interfaces to 800 MHz primary antenna; • Diplexer Diversity (Cellular Band A), interfaces to 800 MHz diversity antenna. For a schematic of the PCS multiplexers, see Figure 21. For a schematic of the Cellular/SMR multiplexers, see Figure 22. Page 26 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Primary Antenna Quadplexer PCS Band A/B/F Diversity Antenna Quadplexer PCS Band D/E/C Antenna Assembly Rx 1850-1910 Tx 1930-1945 Tx 1950-1965 Tx 1970-1975 Rx 1850-1910 Tx 1945-1950 Tx 1965-1970 Tx 1975-1990 Rx MCPA MCPA MCPA Rx MCPA MCPA MCPA Tx Tx Tx RUC RUC RUC Tx Tx Tx RUC RUC RUC Primary Diversity Multicoupler 1850/1910 21270-A Figure 21. PCS Multiplexers Primary Antenna Duplexer 800 Mhz Band Rx 810-849 Rx SMR A” B’ Diversity Antenna Triplexer 800 Mhz Band Antenna Assembly Tx 869-880 Rx 810-849 Tx 855-866 Tx 880-894 MCPA MCPA MCPA Rx SMR A” Tx A” A Tx Tx SMR-A B B’ RUC RUC RUC Multicoupler 810-849 21271-A Figure 22. Cellular/SMR Multiplexers Page 27 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1.11 Circuit Breaker Panel The Circuit Breaker Panel, shown in Figure 23, contains five circuit breakers. It distributes the RAN’s -48 VDC power and protects the RAN’s electronics. Table 15 gives the circuit breaker functions. Table 16 describes the panel LEDs. SYSTEM OK LEDs FAULT LEDs CIRCUIT BREAKER (5 PLACES) 21320-A Figure 23. Circuit Breaker Panel Table 15. Circuit Breaker Functions BREAKER FUNCTION 1A PA1 2A PA2 3A PA3 4A PA4 5A cPCI chassis Table 16. Circuit Breaker Panel LEDs REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION OK Green LED Okay. Lights when AC power is present FAULT Red LED Fault. Lights when rectifier is limiting current 1.12 Backup Batteries The NXD RAN has two backup battery options: • Extended Batteries: provide backup protection for up to two hours. These are four 12V, 85-100 AH internal batteries connected in series for a -48V system. The four batteries together with associated wiring and hardware weigh 325 pounds (147.7 kg). Page 28 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 • Glitch Batteries: provide backup protection for up to five minutes. These are small, motorcycle type batteries connected in a series configuration. 1.13 Antenna ADC provides a pole-mount antenna kit for use when the RAN is mounted on a wooden utility pole. The kit must be separately ordered from the RAN. Pole mounting is the most common type of RAN installation. The antenna offered interfaces with the PCS and Cellular/SMR bands and supports two branch diversity receive paths. Also included in the kit is the GPS antenna used by the RAN. The RAN may also be mounted outdoors on a concrete pad. This type of installation may use a conventional directional antenna in either a sector or quasi-omni antenna configuration, depending on the coverage objective and design. Proper antenna selection and the mounting installation are the responsibility of the design engineer. Antenna installation is covered in separate publications, available for downloading from the ADC web site, www.adc.com. Refer to RELATED PUBLICATIONS on Page vii. 2 STANDARD INSTALLATION PROCEDURES This section provides the standard procedures for a typical installation. The RAN may be installed either on a wooden pole or on a concrete pad. This section is organized as follows: • Sections 2-1 through 2-4 provide information that is relevant before installing the cabinet. These subsections contain an installation overview, unpacking instructions, a list of required material and tools, and site preparation guidelines. • Section 2-5 tells how to install a cabinet on a wooden utility pole. Included are instructions for installing the pole mount bracket and then installing the cabinet on the bracket. Also included are instructions for installing the rain shields. • Section 2-6 tells how to install the RAN on a concrete pad. Included are instructions for pouring the concrete pad, mounting the RAN on the pad, and installing the pedestal enclosure. • Section 2-7 contains other standard procedures typically done at every installation. These procedures describe how to install the solar shield, grounding wire, RF cables, fiber optic cable, AC power, and backup batteries. Note: Section 3 contains instructions for installing a second RAN at the same location. Section 4 provides information on non-standard installation procedures such as installing an electronic module. Installation of the RAN cabinet may proceed separately from the installation of the corresponding Hub equipment. When the installation of the RAN is completed, refer to the Page 29 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Digivance NXD Multi-Band Distributed Antenna System Operation Manual (ADCP-75-209) for system turn-up and test procedures. The procedures in this section assume that the required Outside Plant (OSP) fiber optic cable has already been routed between the Hub and the RAN, that the required antenna has been installed, and that a coaxial cable terminated with an N-type connector has been routed to the RAN from the antenna. Danger: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. Caution: Always allow sufficient fiber length to permit routing of patch cords and pigtails without severe bends. Some fiber optic patch cords or pigtails may be permanently damaged if bent or curved to a radius of less than 2 inches (50 mm). 2.1 Installation Overview A standard (typical) installation of the RAN consists of the following steps: Warning: Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when handling electronic components. Note: To insure that all optical connectors and optical ports remain dust-free during installation, leave all dust caps and dust protectors in place until directed to remove them for installation. 1. Checking out and preparing the installation site. 2. Unpacking and inspecting the shipped items. 3. Installing a pole mount frame or pedestal mount. 4. Installing the RAN cabinet on the pole or pad. 5. Installing the rain shields (pole mount) or pedestal enclosure (pad mount). 6. Installing the solar shield. 7. Installing a ground wire. 8. Connecting RF cables between the antenna and RAN. 9. Installing the fiber optical cable that connects the RAN to the Hub. 10. Installing AC power. 11. Installing backup batteries in the cabinet. Page 30 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 2.2 Unpacking and Inspection The RAN is shipped to the field pre-configured with all modules and components that the customer has ordered. Electronic modules except for the batteries are shipped already installed in the cabinet. The following optional accessories may also be shipped with the RAN: • Back-up batteries • Non-standard SFP optical transceiver Use the following procedure to unpack and inspect the RAN components: 1. Open the shipping cartons and carefully unpack each component from the protective packing material. 2. Check each component for broken or missing parts. If there are damages, contact ADC for an RMA (Return Material Authorization) and to reorder if replacement is required. For contact information, refer to Section 6 on Page 72. 2.3 Required Materials and Tools The following materials must be supplied by the installer: • (Pole mount only) Three galvanized steel square headed bolts with minimum tensile strength of 20,050 lbs., 3/4 in. diameter, and of a length appropriate to pole diameter; Three nuts for bolts, three flat washers, three split ring washers, and three 3-in. square curved washers (see Figure 26 on Page 39) • (Pad mount only) Four 1/2 in. diameter galvanized steel bolts with four lock washers, four flat washers, and four concrete anchors (see Figure 28 on Page 41) • 3M 8426-9M cold shrink • 3M Skothkote Electrical Coating 14853 • Ten Type N plugs (CommScope PN: 540ANM or equivalent) • Coaxial cable (CommScope PN: FXL540OPE or equivalent) • Electrician’s tape • Water seal • Electrical conduit • Conduit fittings • Connector sealant material • Panduit LLCF6-14B-L or equivalent (X2) • Two-hole compression lug terminal for #6 AWG wire • Ground rod • Connector for attaching #6 AWG grounding wire to approved ground source Page 31 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 The following tools are required to perform this procedure: • • • • • • • • • 2.4 Torque wrench Drill Drill bit (appropriate for pole width and 3/4 in. bolts) 7/16 in. open-end wrench Compression pliers for #6 AWG grounding lug Wire cutters Wire strippers Conduit cutter Conduit bender Site Preparation This section describes site preparation for installation and is presented only as a guideline for a typical RAN installation. 2.4.1 Space Requirements When an installation site for the RAN is selected, either on a utility pole or concrete pad, care must be exercised to ensure that the site provides adequate space and clearance to accommodate the current installation and any future upgrades. Table 17 gives RAN dimensions. Table 17. RAN Dimensions CONFIGURATION WIDTH HEIGHT DEPTH RAN 31.35 in. (76.7 cm) 36.5 in. (92.7 cm) 27.5 in. (69.9 cm) Dual RAN 31.25 in. (76.7 cm) 72 in. (182.9 cm) 27.5 in. (69.9 cm) 2.4.2 Power Requirements Power must be available at the RAN site. The RAN requires 240 VAC, single phase, 20 Amps service. Included with the power meter must be surge protection and circuit breakers. The RAN can have up to three 1500 watt rectifiers. For the minimum specified voltage (176 VAC), each can draw up to 10 amps. The RAN will draw up to 1800 watts normally, but when batteries are re-charging that amount will increase the current draw into a RAN to up to 16 Amps. Therefore, one 20 Amps service is required per four band RAN. Page 32 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 In a pole mount installation, the power meter is typically installed on the pole below the unit in separate boxes. In a concrete pad installation, an external junction box is typically placed near the RAN providing AC power, surge protection, and circuit breakers. 2.4.3 Antenna Requirement ADC offers a pole-mount antenna kit (accessory) for use when the RAN is mounted on a wooden utility pole. Either a 2 in. (5.08 cm) O.D. model or a 9 in. (22.86 cm) O.D. model can be ordered. Pole mounting is the most common installation. The antenna interfaces with the PCS and Cellular/SMR bands and supports two branch diversity receive paths. Also included in the kit is the GPS antenna used by the RAN. Installation instructions for the pole mount antenna are included with the kit. When the RAN is mounted on a concrete pad, a conventional directional antenna may be used (customer supplied). The antenna may be set to operate in either a sector or quasi-omni configuration, depending on the coverage objective and design. Proper antenna selection and the mounting installation are the responsibility of the design engineer. 2.4.4 RF Cable Requirements RF cables are required at the installation site to provide the physical link between the RAN and the antenna. In a pole-mount installation, U-duct of an appropriate size is also required to cover the RF cables on the pole. The U-duct provides only physical protection. It should not be considered to provide electrical isolation from conductors on the pole. Adequate clearance must be obtained for the routing of these cables past the existing services as defined in the previous topic. In a concrete pad installation, RF cables from the antenna are routed and protected per the installation plan provided by the design engineer. 2.4.5 Fiber Requirements Optical fibers are required at the site to provide the physical link between the RAN and the Hub. In a typical installation, the identified fibers are broken out of a multi-fiber sheath and routed to a splice box where they are spliced to pigtails connecting the main sheath to the RAN. The actual fiber bundle location on the utility pole may vary per the agreed to attachment point. Refer to Figure 24. The nylon cable connector on the rear of the RAN accommodates cables of a diameter in the range .38 to .50 inches (.97 to 1.27 cm). For larger size cables, refer to Section 1.6.2 on Page 9. Page 33 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 2.5 Installing a RAN Cabinet on a Wooden Utility Pole Figure 24 shows the main components and their spatial placement in a typical NXD RAN pole mount installation. 2.5.1 Site Requirements Unique to Pole Mounting Locations If power lines are present at the top of the pole, spacing requirements applicable to the RF cabling and any other hardware installed in the electric space must be considered. Per the National Electrical Safety Code, vertical clearance at supports for primary-supply conductors above other facilities is required to be 16 in. (40.64 cm) above neutrals and 40 in. (101.6 cm) above communications (60 in. [152.4 cm] if above 8700V). For supply conductors at voltages up to 8700 between conductors, the minimum horizontal clearance provided by the NESC ANSI C2 is 12 in. (30.5 cm). For higher voltages, it is required that .4 in. (10.2 mm) be added for every 1000V above 8700. Table 18 lists the required clearances for some common high voltages. Table 18. Antenna Clearance vs. Voltage VOLTAGE HORIZONTAL CLEARANCE 8700V 12.0 in. (30.5 cm) 15 kV 14.52 in. (36.9 cm) 28 kV 19.72 in. (50.1 cm) 38 kV 23.72 in. (60.2 cm) This information is from the Standard Handbook for Electrical Engineers, 13th Edition, McGraw Hill, Chapter 18, Section 151, Pages 18-65. Page 34 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 ANTENNA ANTENNA MOUNTING BRACKET ANTENNA 100 IN. (254 CM) RF CABLES TO RAN (5 REQUIRED) GROUND WIRE TO ANTENNA PRIMARY POWER PRIMARY POWER SECONDARY POWER SECONDARY POWER LINE FIBER OPTIC LINE FIBER 2 IN. SCHEDULE 40 CONDUIT FOR POWER IN CARLTON PT. NO. 49011-010 OR EQUIVALENT 38.6 FT. (11.8 M) TYPICAL 27.5 IN. (69.85 CM) FIBER SPLICE CAN 3 IN. SCHEDULE 40 CONDUIT FOR RF CABLES CARLTON PT. NO. 49013-010 OR EQUIVALENT 31.25 IN. (79.4 CM) JUNCTION BOX #6 AWG COPPER GROUND WIRE TO METER BOX, RAN, AND ANTENNA 1.5 IN. SCHEDULE 40 POLE RISER FOR FIBER OPTIC LINES CARLTON PT. NO. 59010N OR EQUIVALENT 10 FT. (3 M) TYPICAL 7 FT. (2.1 M) TYPICAL SIDE VIEW FRONT VIEW COPPER GROUND ROD 21285-A Figure 24. Typical Pole-Mount Installation 2.5.2 Pole Loading Analysis A pole loading analysis should be performed before the RAN is mounted on the pole to verify that the pole can support the weight of the RAN in various conditions. The analysis should take into account the pole top antenna, the RAN and batteries, and the possibility of an expansion RAN with batteries. Table 19 lists the weights of various NXD components and configurations. Page 35 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 Table 19. RAN Component Weights CONFIGURATION OR COMPONENT WEIGHT Base RAN without batteries 379 lbs. (172.3 kg) Base RAN with four batteries 679 lbs. (308.6 kg) Expansion RAN with four batteries 619 lbs. (281.4 kg) Antenna pole-mount bracket (9 inch) 56 lbs. (25.5 kg) Antenna pole-mount bracket (2 inch) 57 lbs. (25.9 kg) Pole-top antenna (9 inch) 47 lbs. (21.4 kg) Pole-top antenna (2 inch) 12 lbs. (5.5 kg) Three load types should be considered: static weight loading, ice loading, and wind loading. These types should be considered on the pole, wires, and any equipment installed on the pole. A qualified engineer should perform the pole loading analysis, taking into account both vertical and horizontal forces. The specified horizontal load is applied 2 ft. (60.1 cm) from the top and the assumption is that the pole acts as a cantilever with maximum stresses applied at the ground level. Table 20 provides acceptable loads by pole class. Table 20. Loading by Pole Class POLE CLASS HORIZONTAL LOAD 5400 lbs. (2454.5 kg) 3700 lbs. (1681.8 kg) 3000 lbs. (1363.6 kg) The strength of the wood pole is defined in Standard Handbook for Electrical Engineers, 13th Edition, McGraw Hill, Chapter 18, Section 135, “Strength of Wood Poles,” Pages 18-57. The wood pole strength calculation is defined in Standard Handbook for Electrical Engineers, 13th Edition, McGraw Hill, Chapter 18, Section 136, Reference NEC. 2.5.3 Installing the Cabinet Mounting Bracket The Digivance NXD Wood Pole Mounting Bracket, shown in Figure 25, is an accessory item that is used to attach the Digivance NXD cabinet to a power distribution pole or related object. The bracket is attached to the pole using galvanized steel square head bolts that are attached through holes drilled through the wooden pole. An example of an installed NXD wood pole mounting bracket is shown in Figure 25. Use the following procedure to install the RAN wood pole mounting bracket: 1. Determine the mounting height of the RAN and mark the pole at the desired location of the base of the RAN. Note: Install the RAN pole mount bracket on the side of the utility pole assigned by the utility company or required by local zoning. Page 36 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 UTILITY POLE MOUNTING BRACKET 2.63 IN. (6.7 CM) RAN ATTACHMENT POINTS 13.5 IN. (34.3 CM) 34.5 IN. (87.6 CM) 29.25 IN. (74.3 CM) HOT DIPPED GALVANIZED MACHINE BOLT SQUARE HEAD 3/4 x 16.00 LG W/NUT (J9816) 3 REQUIRED ROUND FLAT WASHER 2.00 O.D. (J1089) 3 REQUIRED 10 FT. (3 M) TYPICAL SQUARE CURVED WASHER 3 x 3 x 1/4 (J6823) 3 REQUIRED SPRING LOCK WASHER .234 x.188 (J140) 3 REQUIRED OR EQUIVALENT 21286-A Figure 25. Cabinet Mounting Bracket 2. Place the pole mount bracket against the pole. 3. Strap or otherwise hold the bracket in place. 4. Using a level, adjust the bracket to make it vertically level. 5. Mark the three holes to be drilled through the wood pole. 6. Remove the pole mount bracket. 7. Drill three holes through the pole using a 7/8 in. wood bit. 8. Using a 3/4 in. machine bolt, put a 2 in. flat washer on the bolt. 9. Place the pole mounting bracket against the pole. 10. Align the holes in the bracket with the holes drilled in the pole. 11. Install one bolt through the bracket and pole (using any of the three holes). 12. Place a 3 in. square curved washer, lock washer, and 3/4 in. nut on the other end of the machine bolt; do not tighten. 13. Repeat steps 8-12 for the other two holes. 14. Using a 1-1/8 in. wrench, tighten the mounting hardware to 103 ft.-lbs. Page 37 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 2.5.4 Mounting the RAN Cabinet on the Bracket The cabinet is shipped with the mounting hardware required for mounting the RAN cabinet on the RAN wood pole mounting bracket. The hardware consists of six 1/2 in. bolts, six nuts, 12 lock washers, and 12 flat washers. Use the following procedure to mount the cabinet. Refer to Figure 26. Caution: Do not install batteries in the RAN prior to mounting the RAN securely on the utility pole. 1. Remove the RAN from the mounting pallet. 2. Securely attach the boom truck cable to the four hoist eyes of the RAN. 3. Carefully raise the RAN toward the cabinet mounting bracket. 4. With a person in the bucket truck and positioned at the RAN pole mounting bracket, guide the RAN onto the RAN pole mounting bracket so that the RAN holds onto the studs on the mounting bracket. Note: Once the RAN is hung on the studs, the through bolts will self-align. 5. Place a lock washer and a flat washer on a 1/2 in. by 1-3/4 in. bolt. 6. Screw the bolt in hand tight. 7. Repeat the previous two steps for the remaining five mounting holes. 8. Install a flat washer, lock washer, and nut on each of the six studs. 9. Using a 3/4 in. wrench, tighten the bolts to 75 ft.-lbs. 10. Carefully detach the boom truck cable from the hoist eye of the RAN. 11. Remove the hoist eyes by unscrewing from the RAN top. 2.5.5 Installing the Rain Shields There are two rain shields to be installed on the rear of the RAN. They are identified as “rain shield right” and “rain shield left.” Use the following procedure to install the rain shields. Refer to Figure 26. 1. Using the supplied hardware, place the left rain shield over the three studs in the pole mount bracket and three studs on the RAN. 2. Place a lock washer then a nut on each stud. 3. Using a nut driver or wrench, tighten to 6 ft.-lbs. Page 38 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 RAIN SHIELD RIGHT UTILITY POLE RAN CABINET RAIN SHIELD LEFT POLE MOUNT BRACKET 21345-A Figure 26. Pole Mount Components 2.6 Installing a RAN Cabinet on a Concrete Pad This section contains the procedures for installing the RAN on a concrete pad. Choose an installation site that conforms to all local codes. Obtain all required permits prior to starting installation. Situate the concrete pad along the trench that was used for routing the OSP fiber cables for the system. Page 39 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 2.6.1 Pouring a Concrete Pad Prepare a base for the concrete pad that meets all local code requirements. The base must have a footing of 4 to 6 inches (10.2 to 15.2 cm) of sand or gravel on firmly compacted soil. Concrete pad height is site and climate dependent. Height should be based on keeping the front door air intake louvers and rear bottom exhaust vent free of obstruction. For dimensions of pad, refer to Figure 27. 31.0 IN. (79 CM) DOOR CLEARANCE 92.0 IN. (234 CM) RAN CABINET/ PEDESTAL ENCLOSURE FOOT PRINT CONCRETE PAD (MINIMUM SIZE) 15.38 IN. (39.07 CM) HOLES FOR PEDESTAL MOUNT 24.0 IN. (61 CM) 29.00 IN. (73.66 CM) 3.5 IN. (8.9 CM) 4.3 IN. (10.9 CM) 36.0 IN. (91 CM) 21308-A Figure 27. Concrete Pad Dimensions 2.6.2 Mounting the Cabinet on a Concrete Pad Use the following procedure to mount the cabinet on the concrete pad. 1. Fasten the pedestal mounts to the concrete pad using the customer-supplied hardware identified in Figure 28. Page 40 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 1/2 x 13 BOLT LOCK WASHER FLAT WASHER CONCRETE ANCHOR 21306-A TYPICAL CUSTOMER SUPPLIED HARDWARE (4 PLACES) Figure 28. Installing Pedestal Mount and Cabinet Warning: Use appropriate lifting equipment when moving or installing the cabinet. Do not stand under the cabinet as it is being hoisted into position for installation. A failure of the lifting equipment could result in serious personal injury. 2. Using appropriate lifting equipment, lower the cabinet into position on the cabinet mounts. 3. Secure the cabinet from the side, as shown, using the four bolts, four flat washers, and four lock washers from the shipping pallet mounting brackets. Page 41 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 2.6.3 Installing the Pedestal Enclosure The pedestal enclosure, shown in Figure 29, mounts on the back of the cabinet. PEDESTAL ENCLOSURE 21309-A CUSTOMER SUPPLIED OPTIONAL FITTINGS Figure 29. Installing Pedestal Enclosure Use the following procedure to install the pedestal enclosure: 1. Orient the pedestal enclosure as shown and attach it to the back of the cabinet using the four bolts provided. 2. Close the pedestal enclosure door and secure the door with the key provided. Page 42 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 2.7 Other Standard Installation Procedures This section contains other procedures done at every installation after the RAN is mounted on a wooden pole or concrete pad. 2.7.1 Installing a Solar Shield Each RAN has a solar shield that mounts on top of the cabinet. Hardware for the solar shield can be found in a bag fastened to the inside of the battery compartment. The hardware consists of two 1/4 in. bolts, each with flat washer and sealing washer. Use the following procedure to install the solar shield. Refer to Figure 30. 1. Remove the solar shield from its packaging. 2. Place a lock washer and flat washer and then the sealing washer on each 1/4 in. machine bolt. 3. Using the key provided, open the RAN door. SOLAR SHIELD RUBBER SEALING WASHER FLAT WASHER TANGS 1/4 x 20 HEX HEAD BOLT EACH SIDE 21339-A Figure 30. Installing the Solar Shield Page 43 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 4. Locate the two 1/4 in. machine bolts, each with flat washer and sealing washer, in a bag fastened to the inside of the battery compartment. 5. Place the solar shield on the top of the RAN. 6. Push the solar shield backward until it extends slightly beyond the back of the cabinet then pull it forward catching the two tangs of the solar shield on the top of the RAN. 7. Locate the two clearance holes on the left and right sides just inside the door frame. 8. Align the solar shield threaded holes with the clearance holes and insert the two 1/4 in. machine bolts in the hole. 9. Using a 7/16 in. nut driver or socket screw, tighten the two 1/4 in. machine bolts to secure the solar shield. Tighten to 6 ft.-lbs. 2.7.2 Installing a Ground Wire Each RAN is designed with provisions for connecting to earth ground. Earth grounding is to be done in accordance with the National Electric Code and local building code. Two ground studs for connecting the ground wire are located on the back of the RAN (Figure 31). A 2-hole compression type lug terminal should be installed on the ground studs for connecting a #6 AWG copper grounding wire. The following material must be supplied by the installer: • Panduit LLCF6-14B-L or equivalent (X2) • Two-hole compression lug terminal for #6 AWG wire • #6 AWG wire • Connector for attaching the wire to an approved ground source The following tools are required to perform this procedure: • Compression pliers for #6 AWG grounding lug • Wire cutters • Wire stripper Use the following procedure to install the ground wire: Caution: For proper equipment operation, an approved earth ground connection must be provided. The recommended minimum wire size is #6 AWG copper wire. 1. Obtain a length of #6 AWG (4 mm) copper wire for use as a cabinet grounding wire. 2. Crimp the #6 AWG copper grounding wire to the compression lug. 3. Secure the compression lug to the back of the cabinet. 4. Route the free end of the grounding wire to an approved earth ground source. 5. Cut the grounding wire to length and connect it to the earth ground source as specified by local code. Page 44 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 RF LINE CONDUIT (FROM ANTENNA) FIBER OPTIC CONDUIT FIBER OPTIC ENTRANCE RIGHT RAIN SHIELD LEFT RAIN SHIELD POWER ENTRANCE 220 VAC PRIME POWER TYPE N CONNECTORS FOR ANTENNA AND GPS CONNECTORS GROUND LUG GROUND WIRE 220 VAC RIGID CONDUIT 21287-A Figure 31. Cable Connection Points 2.7.3 Installing RF Cabling RF cabling on the RAN connects the RF antenna to the RF input on the back of the RAN. There are five Type N receptacles on the antenna and five Type N receptacles on the back of the RAN, identified in Table 21 on page 47. There are two main steps in installing RF cables: weatherproofing the cables, and routing and securing the cables. Page 45 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 2.7.3.1 Weatherproofing RF Cables RF cables should be weatherproofed before being installed. The following materials are required (customer supplied): Note: Read and understand the manufacturer’s instructions prior to using these products. • 3M 8426-9M cold shrink • 3M Skothkote Electrical Coating 14853 Use the following procedure to weatherproof the RF cables: 1. Prior to connecting the RF cables to either the RAN or antenna, place one 3M 8426-9M cold shrink kit over the cable end, then connect the cable end to its intended termination point. Follow the manufacturer’s directions, which are included with each kit. 2. After the cold shrink has been applied, coat the entire length of the cold shrink material with the 3M Scotchkote Electrical Coating, number 14853. 2.7.3.2 Routing and Securing RF Cables For cable installation, the following materials are required (customer supplied): • 10 Type N male plugs (CommScope PN: 540ANM or equivalent) • Coax cable (CommScope PN: FXL540OPE or equivalent) • Electrician’s tape • Water seal Use the following procedure to route and secure the RF cabling: 1. Measure from the antenna base connectors to the RAN connectors to determine the coax cable length including service loops and drip loops. Refer to Figure 24 on Page 35. 2. Install the Type N plugs on each end of each of the RF cables. Note: Right angle connectors may not be needed if there is enough space or if the coax cable is flexible enough to create a proper bend radius in the cable. Reference the coax cable manufacturer specifications for allowable bend radii. Note: A cable sweep test is highly recommended. When testing the RF and GPS coaxial cables, use a matched load. The VSWR should be 1:1:1. The return loss should be 26.444 dB or better. 3. Attach each end of the cables to the appropriate connectors on the antenna base and the RAN. Refer to Figure 32 and Table 21. 4. Tighten each connector to 20 ft.-lbs. 5. After each connector is tightened, cover the entire connection with electrician’s tape, then wrap the connection in water seal and finally cover the water seal with wraps of electrician’s tape. Page 46 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 GPS PCS-P PCS-D CELL/SMR-P CELL/SMR-D 21278-A Figure 32. Installing the RF Cables Table 21. RAN Antenna Ports and Antenna Base Ports LABEL ON RAN LABEL ON ANTENNA BAND GPS GPS Global Positioning System (GPS) PCS-P PCS-T PCS primary receive path and transmits from PCS A, B or F PCS-D PCS-B PCS diversity receive path and transmits from PCS D, E or C CELL/SMR-D CELL/SMR-D Cell/SMR primary receive path and transmits from Cell A”/A CELL/SMR-P CELL/SMR-P Cell/SMR diversity receive path and transmits from SMR A or Cell B/B’ Note: When building out RANs, connect the quadplexers that will contain the first PCS bands to the top of the PCS antenna element. On the Phasar antenna, this is marked on the base PCS-T. 2.7.4 Installing Pre-Connectorized Indoor/Outdoor Fiber Optic Cable Fiber optic cable installation consists of routing a pre-connectorized outdoor-rated fiber optic cable from an external splice enclosure to the NXD RAN cabinet, routing the cable into the cabinet, and then breaking out the individual fibers for connection. The NXD RAN has a fiber interface on the front of the Synchronous Interface (SIF) Module in the RAN chassis. The fiber enters the cabinet on the rear side. Page 47 © 2006, ADC Telecommunications, Inc. ADCP-75-210 • Issue 1 • November 2006 All fiber optic cable connections require single-mode Dual-LC type connectors. Figure 33 shows the basic configuration of the optical path between the Hub SIF and the RAN SIF. For optical specifications, refer to Table 2 on page 6. BASIC CONFIGURATION BETWEEN HUB SIF SFP AND RAN SIF SFP FIBER PORT TX FIBER PORT RX TX RX REVERSE PATH FORWARD PATH END-TO-END OPTICAL CONNECTOR/CABLE ASSEMBLY DIAGRAM 21353-A Figure 33. Optical Path Between Hub SIF and RAN SIF For fiber cable ingress, the RAN is equipped with a nylon fiber optic connector located on the rear side of the cabinet. The connector accommodates cables of a diameter in the range .38 to .50 inches (.97 to 1.27 cm). Note: If the installer has a larger cable, the manufacturer (Hubbell Inc.) makes bushings that fit this connector in the following size ranges: .500-.625, .625-.750, .750-.875, .8751.00, 1.00-1.125 inches. Use the following procedure to install the fiber optic cable: Note: The routing of an Outside Plant (OSP) fiber optic cable from the Hub to a splice enclosure in the vicinity of the RAN cabinet and the splicing of selected OSP cable fibers to the fibers in the outdoor-rated cable is the responsibility of the installer. Warning: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transmitter of any unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transmitter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector. 1. Route the connectorized end of the fiber optic cable from the splice enclosure (not provided) to the rear side of the cabinet. Estimated length of cable is 30 feet (9 meters) although this is dependent upon distance from the splice enclosure. Page 48 © 2006, ADC Telecommunications, Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Modify Date : 2006:12:14 11:21:50-06:00 Create Date : 2006:12:14 11:21:43-06:00 Metadata Date : 2006:12:14 11:21:50-06:00 Creator Tool : FrameMaker 7.2 Format : application/pdf Title : 75210.book Document ID : uuid:7876b62d-9938-4db7-8840-52e7b0cb0c66 Instance ID : uuid:88a22235-16b7-49b6-898f-e886337aced4 Producer : Acrobat Distiller 7.0.5 (Windows) Page Count : 40 Creator : FrameMaker 7.2EXIF Metadata provided by EXIF.tools