ADC Telecommunications PSMAWS2D FWP-A4MT000MOD User Manual

ADC Telecommunications Inc FWP-A4MT000MOD

User Manual

TECP-77-141  Issue 2  August 2012300001744178 Rev BDual-Band Dual-Slot RF ModuleSingle-Slot RF ModuleDual-Slot 40W RF Module HDM RF ModuleFlexWave Prism®RF Modules for Prism Remote UnitsInstallation Guide
Copyright© 2012 TE Connectivity, Inc. All Rights Reserved.Information contained in this document is company private to TE Connectivity Ltd., and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of TE.Trademark InformationFlexWave, FlexWave Prism, InterReach Spectrum, InterReach Unison, Universal Radio Head, TE Connectivity, and TE connectivity (logo) are trademarks.All other logos, products and/or company names referred to herein might be trademarks of their respective owners. Disclaimer of LiabilityContents herein are current as of the date of publication. TE reserves the right to change the contents without prior notice. Should the content of printed user documentation shipped with product differ from documentation provided on a product CD (inclusive of the associated Help modules), the printed user documentation supersedes the documentation on the product CD. In no event shall TE be liable for any damages resulting from loss of data, loss of use, or loss of profits, and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period.Specific Disclaimer for High-Risk ActivitiesThis Product is not specifically designed, manufactured, tested or intended for use in high-risk activities including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear facility. TE (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of fitness for such purposes or any other purposes.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 1TECP-77-141 • Issue 1 • April 2012 ©2012 TE Connectivity Ltd.TABLEOFCONTENTSTopics PagePreface .................................................................................................................................................................2RevisionHistory...................................................................................................................................................... 2FlexWavePrismUserDocumentation.................................................................................................................... 2AccessingUserDocumentationontheCustomerPortal ...................................................................................................3DocumentCautionsandNotes...........................................................................................................................................3StandardsCertification........................................................................................................................................... 4OverviewofRFModulesforPrismRemoteUnits..................................................................................................5RFModuleComponents......................................................................................................................................... 8DuplexerandLowNoiseAmplifier .....................................................................................................................................9LinearPowerAmplifiers .....................................................................................................................................................9DigitalProcessingModule ................................................................................................................................................10RFModuleCables .............................................................................................................................................................10RFModuleCablesforSingle‐Card,Dual‐Card,andHDMRFModules................................................... 10RFModuleCablesforDual‐SlotInstallations......................................................................................... 12PrismRemoteUnitRFGroupAssignments ......................................................................................................................13PRURFModuleTypes .......................................................................................................................................... 16PrismRemoteUnitSingle‐andDual‐CardRFModules ....................................................................................................16PrismRemoteUnitHDMRFModules ..............................................................................................................................17PrismRemoteUnitDual‐Slot40WRFModules................................................................................................................18InstalltheRFModule(s)......................................................................................................................................19SafetyPrecautions................................................................................................................................................ 19GuardAgainstDamagefromElectro‐StaticDischarge......................................................................................... 20UnpackandInspecttheRFModule ..................................................................................................................... 20RemoveReleaseLinersfromtheRFModule ....................................................................................................... 21Dual‐SlotModulesOnly—RemovetheModuleSlotShelf ................................................................................... 23InstalltheRFModuleintothePrismRemoteChassis.......................................................................................... 24SecureRFModuleLatches ................................................................................................................................... 32ConnectLatchesonSingle‐SlotandHDMRFModules ....................................................................................................33ConnectLatchesonDual‐BandDual‐SlotRFModules .....................................................................................................34LatchesonDual‐Slot40WRFModules.............................................................................................................................35VerifythattheRFModuleMountingHookisEngaged ....................................................................................................35ConnecttheRFModuleCables ............................................................................................................................ 36PowerontheRFModule...................................................................................................................................... 42ContactingTEConnectivity .................................................................................................................................43ContactingTEConnectivitybyTelephone............................................................................................................ 43OnlineAccesstoTEConnectivity ......................................................................................................................... 43
Preface  Page 2 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012PREFACEThismanualprovidestheinformationyouneedtoinstallTEConnectivityFlexWavePrism®RFModulesintoaPrismRemoteUnit(PRU).InstallationinstructionsareprovidedforthefollowingPrismRemoteUnitRFModules:•Single‐SlotRFModules,whichincludestheHDMRFModules•Dual‐SlotRFModules–Dual‐CardRFModules–40WRFModules.NOTE: ThisinstallationguidedocumentstheRFModulesthatarecompatiblewiththeFlexWavePrismRemoteUnit,whichisdesignedforoutdooruse.ForinformationontheRFModulesdesignedforusewiththeFlexWavePrismIndoorRemoteUnits(IRUs),seetheFlexWavePrismIndoorRemoteUnitInstallationGuide(TECP‐77‐197).RevisionHistoryTable 1. Revision HistoryIssue Document Date Technical Updates1April 2012 Original2December 2012 •Updated Table 2 on page 3 with new Prism user documentation list.•Updated Table 3 on page 7 to add new RF Modules.•Removed the Specifications section, which included the RF and Optical Specifications and the Frequency and Composite Output Power at Antenna Port (dBm) for Prism Remote Units tables; to access these performance specifications, refer to the Flexwave Prism Performance Specifications (TECP-77-201).•Updated “Contacting TE Connectivity” on page 43.FlexWavePrismUserDocumentationFlexWavePrismuserdocumentationisintendedforsystemadministrators,engineersandinstallersresponsibleforplanning,administering,configuring,andmaintainingFlexWavePrismsystems.Table2onpage3liststhemanualsthatcorrespondtothefeaturesoftheFlexWavePrismRFModulesdescribedinthisinstallationguide.
Table2.FlexWavePrismUserDocumentationTitle Catalog Number ElementManagementSystem7.3and7.4UserGuideTECP-77-212HostUnitIIInstallationGuide TECP-77-206HostUnitExpansionUnitInstallationGuide TECP-77-202HostUnitIIandHostUnitExpansionUnitModuleReplacementGuide TECP-77-207PrismRemoteUnitInstallationGuide TECP-77-142RFModulesforPrismRemoteUnitsInstallationGuide(1)TECP-77-141IndoorRemoteUnitInstallationGuide TECP-77-197OADMSpliceBoxInstallationGuide TECP-77-208CoarseWavelengthDivisionMultiplexerUserGuide TECP-77-209FlexwavePrismPerformanceSpecifications TECP-77-2011 The Prism Remote RF Modules and Remote Mounting Kit are designed for use only in the Prism Remote Unit (PRU). The IRU RF Modules and mounting options are described in the FlexWave Prism Indoor Remote Unit Installation Guide (TECP-77-197).FlexWave Prism User DocumentationFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 3TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.AccessingUserDocumentationontheCustomerPortal1ClickonthefollowingURLlinkorentertheURLintoyourwebbrowser,andthenpressEnteronyourkeyboard:http://www.adc.com/Americas/en_US/1268116693520NOTE: AccesstotheCustomerPortalrequiresauseraccountandpassword.Ifyoudonothaveanaccount,clickontheregistrationlinkontheLogInpage.2OntheCustomerPortalHomepage,clickManuals&SpecSheets.3OntheManuals&SpecSheetspage,clickonthetitleofthemanualthatyouwishtoopenordownload.DocumentCautionsandNotesTwotypesofmessages,identifiedbelow,appearinthetext:CAUTION! Cautiontextindicatesoperationsorstepsthatcouldcausepersonalinjury,induceasafetyprobleminamanageddevice,destroyorcorruptinformation,orinterruptorstopservices.NOTE: Notetextcontainsinformationaboutspecialcircumstances.
Preface  Page 4 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012StandardsCertificationFCC:ThisequipmentcomplieswiththeapplicablesectionsofTitle47CFRPart15(HostUnit),Part22(800MHzCellular),Part24(1900MHz‐PCS),Part90(800/900‐SMR),andPart27(2100MHz‐AWS)&(700MHz‐LTE).IC:ThisequipmentcomplieswiththeapplicablesectionsofRSS‐131.Theterm“IC:”beforetheradiocertificationnumberonlysignifiesthatIndustryCanadaTechnicalSpecificationsweremet.TheManufacturer'sratedoutputpowerofthisequipmentisforsinglecarrieroperation.Forsituationswhenmultiplecarriersignalsarepresent,theratingwouldhavetobereducedby3.5dB,especiallywheretheoutputsignalisre‐radiatedandcancauseinterferencetoadjacentbandusers.Thispowerreductionistobebymeansofinputpowerorgainreductionandnotbyanattenuatorattheoutputofthedevice.Note:TocomplywithMaximumPermissibleExposure(MPE)requirements,themaximumcompositeoutputfromtheantennacannotexceed1000WattsERP(LTE,CellularandSMR),theantennacannotexceed1640WattsEIRP(PCSandAWS),andtheantennamustbepermanentlyinstalledinafixedlocationthatprovidesatleast6meters(20feet)ofseparationfromallpersons.UL/CUL:Thiswillbeinstalledinarestrictedaccesslocation.ThisequipmentcomplieswithType4,perULandCUL50,StandardforEnclosuresforElectricalEquipment.ThisequipmentprovidesthedegreeofprotectionspecifiedbyIP66asdefinedinIECPublication529.FDA/CDRH:ThisequipmentusesaClass1LASERaccordingtoFDA/CDRHRules.Thisproductconformstoallapplicablestandardsof21CFRPart1040.Caution:Modificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatetheequipment.EUHarmonizedStandards:MeetsessentialrequirementsofR&TTE1999/5/EC.•Article3.1a—Theprotectionofthehealthandthesafetyoftheuserandanyotherperson,includingtheobjectiveswithrespecttosafetyrequirementscontainedinDirective2006/95/EC,butwithnovoltagelimitapplying.•Article3.1b—TheprotectionrequirementswithrespecttoelectromagneticcompatibilitycontainedinDirective2004/108/EC.•Article3.2—Inaddition,radioequipmentshallbesoconstructedthatiteffectivelyusesthespectrumallocatedtoterrestrial/spaceradiocommunicationandorbitalresourcessoastoavoidharmfulinterference.EMCStandards:EN55022andEN55024(CEmarked)SafetyStandards:•IEC60950‐1,FirstEdition(CEmarked)•UL60950‐1(FilenumberE174166)(USAandCanada)
Standards CertificationFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 5TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.OVERVIEWOFRFMODULESFORPRISMREMOTEUNITSFigure1illustratesthePrismRemoteUnit(PRU),whichcontrolsRFemissions,interfaceswiththeFlexWaveHost.Single-BandRemoteDual-BandRemoteTri-BandRemoteQuad-BandRemoteFigure1.Prism Remote UnitsThePRUhasfromonetofourRFModuleslots,dependingonthePRUmodel.Thatis,theSingle‐BandPRUhasoneRFModuleslot,andtheQuad‐BandPRUhasfourRFModuleslots.APRUcansupportuptofourRFModules.ThefunctionofthePRURFModulesontheForwardPathisto:•convertthedigitizedRFtransportedfromtheHosttoAnalogRF•amplifytheAnalogRFsignal•providesignalfiltering.ThefunctionofthePRURFModulesontheReversePathisto:•converttheAnalogRFfromthehandsettoDigitalRFfortransporttotheHost•providesignalfiltering.
Overview of RF Modules for Prism Remote Units  Page 6 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012EachRFModulecansupportanyofthefollowingDARTcombinations:•oneClassicDARToroneSingleSuperDART•twoClassicDARTs•twoSingleSuperDARTs•oneDualSuperDART•oneortwosetsofTxorRxBoards(HDM)–HDM‐850hasoneset–HDM‐700hastwosets.EachRFModulewillhaveuptotwo6‐TimeslotDARTsorone12‐TimeslotDARTsperRFModule.TheRFModulesarefieldreplaceable,butcannotbeservicedinthefield.Table3onpage7liststhePrismRemoteUnitRFModulesthataresupportedinthisinstallationguide.
Table3.SupportedFlexWavePrismRFModulesforPrismRemoteUnits(PRUs)Catalog Number Description10W 900 P-GSM Module, Diversity, SGL SD 10w 900 P-GSM Module, Non-Diversity, SGL SD 10W APAC EGSM (885-915) MODULE, SGL SD 10W, EGSM 900, DIVERSITY, SGL SD 10W, EGSM 900, NON-DIVERSITY, SGL SD 20W 2100 UMTS MODULE, DIV Ready, SGL SD 20W 700 Lower ABC MODULE, NON-DIVERSITY, SGL SD20W AWS MODULE, DIVERSITY, SGL SD 20W AWS MODULE, NON-DIVERSITY, SGL SD 20W PCS MODULE, DIVERSITY, SGL SD 20W PCS MODULE, NON-DIVERSITY, SGL SD 20W RF Module, AWS 2100 12S Enclosure20W RF Module, AWS 2100 Diversity Enclosure20W RF Module, AWS 2100 Non-Diversity Enclosure20W RF Module, PCS 1900 12S Enclosure20W RF Module, PCS 1900 Diversity Enclosure20W RF Module, PCS 1900 Non-Diversity Enclosure20W WIDEBAND CELL MODULE, DIVERSITY, CLASSIC 20W WIDEBAND CELL MODULE, NON-DIVERSITY, Classic 20W, GSM 1800, DIVERSITY, SGL SD 20W, GSM 1800, NON-DIVERSITY, DL SD 20W, GSM 1800, NON-DIVERSITY, SGL SD 20W, UMTS 2100, DIVERSITY, SGL SD 20W, UMTS 2100, NON-DIVERSITY, DL SD 20W, UMTS 2100, NON-DIVERSITY, SGL SD 40W 700 Upper C MODULE, NON-DIVERSITY, SGL SD (SGL-SLOT)40W AWS MODULE, NON-DIVERSITY, CLASSIC 40W AWS MODULE, NON-DIVERSITY, SGL SD (DUAL-SLOT) 40W PCS MODULE, NON-DIVERSITY, CLASSIC (DUAL-SLOT) 40W PCS MODULE, NON-DIVERSITY, SGL SD (DUAL-SLOT) 40W WIDEBAND CELL MODULE, NON-DIVERSITY, (SGL-SLOT) 6.5W 800 SMR MODULE, NON-DIVERSITY, CLASSIC 6.5W 800/900 ESMR MODULE, NON-DIVERSITY, CLASSIC 6.5W APAC iDEN Module, Non-Diversity, Classic (Extended 1 MHz) 700 LTE, UPPER C, 20W MODULE, SISO, SGL SDDUAL 20W 700 LOWER ABC MODULE, MIMODUAL 20W 700 UPPER C MODULE, MIMODUAL 20W 850/1900 RF MODULE, (SGL BAY)DUAL 20W 2100 RF MODULE, MIMO, (SGL BAY)40W AWS MODULE, NON-DIVERSITY, SGL SD (SGL-Bay)PRISM, 40W PCS MODULE, NON-DIVERSITY, SGL SD (SGL BAY)Standards CertificationFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 7TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.FWP-K226000MODFWP-K216000MODFWP-F216000MODFWP-6226000MODFWP-6216000MODFWP-9416D00MODFWP-L416000MODFWP-A426000MODFWP-A416000MODFWP-8426000MODFWP-8416000MODFWP-A41S000MOD FWP-A420000MODFWP-A410000MODFWP-841S000MOD FWP-8420000MODFWP-8410000MODFWP-B420000MODFWP-B410000MODFWP-7426000MODFWP-741S000MODFWP-7416000MODFWP-9426000MODFWP-941S000MODFWP-9416000MODFWP-U816100MODFWP-A810000MODFWP-A816000MODFWP-8810000MODFWP-8816000MODFWP-B810100MODFWP-4210000MODFWP-D210000MODFWP-I210000MODFWP-U416000MODFWP-L4MT000MODFWP-U4MT000MODFWP-C4MT000MODFWP-A4MT000MODFWP-A81T000MODFWP-881T000MOD
Overview of RF Modules for Prism Remote Units  Page 8 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012RFModuleComponentsFigure2showstypicalRFModulecomponents,usingtheSingle‐SlotRFModuleasanexample.MountinglatchMounting hookDuplexer Power Amplifier (PA)DARTsFigure2.PRU Single-Slot RF Module ComponentsFigure3showsthecomponentsofanHDMRFModule.Duplexers Power AmplifierMounting latchMounting hookTx and Rx CardsFigure3.HDM RF Module Components
RF Module ComponentsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 9TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.DuplexerandLowNoiseAmplifierTheRFModuleprovidesthePRUwithaninternalDuplexerthatisoptimizedtoprovidethedesiredRFband‐passfilteringandin‐bandequipmentisolationbetweenFWDandREVpaths.TheDuplexerprovidesthefilteringnecessarytothetransmitandreceivepathstotheconnectedantenna.TheDuplexerforthePrismRemoteUnitSingle‐andDual‐CardRFModulesandtheDual‐Slot40WRFModulescontainsuptotwoREVpathLowNoiseAmplifiers(LNAforPRIand/orSECreversepaths).EachLNAprovidesthePrismreversepathwithnominal30dBREVgainandsystemNFof5dBperRXpath.TheDuplexerforanHDMRFModuledoesnothaveaLowNoiseAmplifier.Duplexersarenotfieldserviceable.LinearPowerAmplifiersTheLinearPowerAmplifier(LPA)isahighqualitybroadbandRFamplifierusedforachievingPrismproduct‐ratedpowerforthePRUTxforwardpathspectrumRF.ThePAsarepass‐bandspecific,withthemaximumcompositeTxpowerlevels,and>10dBinstantaneouspeakpowerratinglistedin:•Table4forSingle‐Card,Dual‐Card,andHDMRFModules•Table5onpage10forDual‐Slot40WRFModules.TheLPAishousedwithintheRFModule,andisnotfieldserviceable.Table4.LPAMaximumCompositeTxPowerLevelsforSingle‐Card,Dual‐Card,andHDMRFModulesPassband MaximumdBmWatts InstantaneousBandwidth (MHz)AWS 2100 +43 20 45Cellular 850 +43 20 25+46  40 25EGSM 900 +40  10 35DCS 1800  +42  15.8 75LTE 700 Lower ABC +43  20 18+46  40 18LTE 700 Upper C +43  20 10+46  40 10PCS 1900 +43 20 70PGSM 900 +40 10 25SMR 800 +38 6.5 18SMR 900 +38 6.5 5UMTS 2100 +42  15.8 60
Table5.LPAMaximumCompositeTxPowerLevelsforDual‐Slot40WRFModulesPassband MaximumdBmWatts InstantaneousBandwidth (MHz)PCS 1900 +46 40 70AWS 2100 +46 40 45Overview of RF Modules for Prism Remote Units  Page 10 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012DigitalProcessingModuleTheDigitalProcessingModule(DPM)isfoundonlyintheHDMRFModules.TheDPMprovidestheprimaryprocessingandlogicfunctionsfortheHDMRFModule.ItalsoprovidestheprimarypowerinterfacefortheHDMRFModule,andconversionofthenative28VDCvoltagetolowervoltagesasnecessaryforfunctionality.TheDPMhasaTransmit(Tx)BoardandaReceive(Rx)Board:•TxBoard—providesbandspecificfilteringfortheintendedTransmitpath.•RxBoard—providesbandspecificfilteringfortheintendedReceivepath.RFModuleCablesTheRFModulecablesthatarepre‐installedinthePRUconnecttothecorrespondingconnectorsontheRFModule.TheRFModulecablescorrelatetotheantennaconnectorsonthebottomofthePRUchassis.RFModuleCablesforSingle‐Card,Dual‐Card,andHDMRFModulesTheRFcableandconnectorlabelsalsocorrespondtotheRFModuleslotsinthePRUchassis,whereMODAisthebottomslotandMODDisthetopslot.Intheinstallationsteps,theRFcablesandconnectorsarereferredtoasMODNTX0/RX0andasMODNTRX1whereNequalsA,B,C,orD.ThecablesandconnectorshavecorrespondinglabelsasshowninTable6forSingle‐Card,Dual‐Card,andHDMRFModules.
Table6.RFAntennaLabelsforSingle‐Card,Dual‐Card,andHDMRFModules—FromTopofChassisDownRF Module Cable,RF Module Connector, and Remote Antenna Connector LabelFunctionSingle-SlotRemote Unit RF Module Slot DesignationsDual-Slot Remote Unit RF Module Slot DesignationsDual-Band Tri-Band Quad-BandMod D TX0/RX0Transmit RF power and primary receive to/from the antenna for RF Module DMOD D N/A N/A MOD CMod D TX1/RX1Diversity receive for RF power from the antenna for RF Module DMod C TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module CMOD C N/A MOD BMod C TX1/RX1Diversity receive for RF power from the antenna for RF Module CMod B TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module BMOD B MOD A MOD BMod B TX1/RX1Diversity receive for RF power from the antenna for RF Module BMod A TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module AMOD A MOD A MOD AMod A TX1/RX1Diversity receive for RF power from the antenna for RF Module ARF Module ComponentsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 11TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units  Page 12 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012RFModuleCablesforDual‐SlotInstallationsForDual‐Slotinstallations,theRFcablesandconnectorsarelabeledasMODNTX0/RX0andMODNTX1/RX1,whereNreferstothebottomslotofthedouble‐slotinstallation.Forexample,foraDual‐SlotinstallationinaQuad‐Bandchassis,theRFcablesandconnectorsarelabeledasMODCTX0/RX0andMODCTX1/RX1.ThecablesandconnectorshavecorrespondinglabelsasshowninTable7onpage12forDual‐Slot40WRFModules.Table7.RFAntennaLabelsforDual‐Slot40WRFModules(TopofChassisDown)RF Module Cable,RF Module Connector, and Remote Antenna Connector LabelsFunctionSlots for 40W RF Modules (a) (b)Dual-Band Tri-Band Quad-BandMod D TX0/RX0Transmit RF power and primary receive to/from the antenna for RF Module DN/A N/A Slots C and DMod D RX1 Diversity receive for RF power from the antenna for RF Module DMod C TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module CN/A N/AMod C RX1 Diversity receive for RF power from the antenna for RF Module CMod B TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module BSlots A and B Slots A and B Slots A and BMod B RX1 Diversity receive for RF power from the antenna for RF Module BMod A TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module AMod A RX1 Diversity receive for RF power from the antenna for RF Module A(a) N/A indicates that the slot cannot be used for a Dual-Slot 40W RF Module(b) Install the Dual-Slot 40W RF Module in the lower-most slot in the chassis. If, however, if two Dual-SLot 40W RF Modules are present, install the 2100 Module in the lower-most slot and the 1900 Module in the upper-most slot.
RF Module ComponentsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 13TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.PrismRemoteUnitRFGroupAssignmentsA Prism Remote Unit (PRU) comprises from one to four RF Module slots. Figure 4 illustrates the numbering of RF Module slots and DARTs.Prism Quad-Band Remote Unitwith Single-Card RF ModulesSeRF ModuleDART 7DART 8Group DDART 5DART 6Group CDART 3DART 4Group BDART 1DART 2Group AFigure 4. DART RF Groups in a Prism Remote Unit (PRU)
Overview of RF Modules for Prism Remote Units  Page 14 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012Table 8 lists how the FlexWave Prism EMS references the RF group assignments and corresponding components of each RF Module.Table 8. Remote Unit RF Group Assignments (from Top/Down)Physical RF SlotRF GroupDART NumberLNA Number LPA Numberfor Single LPALPA Number for Dual LPAsPower Detector Number for Single PDPower Detector Number for Dual PDsPrimary DiversityD D 8 8 78787 7 7 7C C 6 6 56565 5 5 5B B 4 4 34343 3 3 3A A 2 2 12121 1 1 1SeRF BoardNOTE: In a dual-LPA system, the Configure Remote Forward Gain page shows two values for the LPA status, one for each LPA. Changing the LPA Mode or resetting the LPA applies to both LPAs at the same time.CAUTION! Should your system experience an LPA problem, refer to Table 8 to ensure that you apply new settings or troubleshoot the correct RF Module.CAUTION! If you use a customized SNMP polling for system status, you must change your LPA indexing scheme.
RF Module ComponentsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 15TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.TheDual‐Slot40WRFModuleoccupiestwoslotsinaPrismRemote.Figure5showsthemaincomponentsinaPrismenclosure,witha40WRFModuleoccupyingSlotsAandB.ThecontrollingDARTwillalwaysbeintheupperslot(BorD),andthesecondLPAisalwaysinthelowerslot(AorC).Dual-slot 40W RF Modulein Slot B (upper slot) and Slot A (lower slot) with the controlling DART in Slot Band the second DART in Slot AAC power switchFour DC power switchesSeRF Module and Power suppliesSlot C (empty for future use)Slot D (empty for future use)FansConnectivity panel with Status LEDFigure5.Dual-Slot 40W RF Module in a Quad-Band Prism RemoteNOTE: IfaDual‐Slot40WRFModuleAWS2100andaDual‐Slot40WRFModulePCS1900arebothinstalledinaQuad‐BandRemote,itisrecommendedthatthePCS1900beinstalledinupper‐mostslot,andtheAWS2100beinstalledinthelower‐mostslot.NOTE: Toaccommodatetwo‐slotmodules,youneedtoremoveamoduleslotshelfasdescribedin“Dual‐SlotModulesOnly—RemovetheModuleSlotShelf”onpage23.
Overview of RF Modules for Prism Remote Units  Page 16 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012PRURFModuleTypesThePRURFModulesareavailableinthefollowingformats,andasdescribedinthefollowingsections:•“PrismRemoteUnitSingle‐andDual‐CardRFModules”onpage16•“PrismRemoteUnitHDMRFModules”onpage17•“PrismRemoteUnitDual‐Slot40WRFModules”onpage18.PrismRemoteUnitSingle‐andDual‐CardRFModulesFigure6showsexamplesofPRUSingle‐andDual‐SlotRFModules,bothofwhichhavetwoDARTs.APRUSingle‐andDual‐CardRFModulecomprises:•oneDART•oneDuplexerwithoneortwointernalLowNoiseAmplifiers(LNAs)•oneLinearPowerAmplifier(LPA)Dual-Band Dual-Slot RF ModuleSingle-Slot Dual-Card RF Module•oneRemoteDARTInterface(RDI)board.Figure6.Single- and Dual-Slot RF Modules
PRU RF Module TypesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 17TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.PrismRemoteUnitHDMRFModulesPRUHDMRFModules(Figure7)aredesignedfor850Cellfrequencies.TheinitialreleaseoftheHDMRFModuleisaSingleInputSingleOutput(SISO)Configurationthat•interfacesoneHostDART—eitherClassicorSuperDART•supportstwonon‐contiguousRFslicesupto25MHztotalbandwidth—SuperDARTonly•supportsupto40WRFoutputpower.Figure7.HDM RF ModuleThecomponentsofaPRUHDMRFModuleisdependentonthemoduletype,aslistedinTable9.Table9.ComponentsofPRUHDMRFModulesRF Module Type DPM LPA Duplexer Rx Card Tx CardSISO 1 1 1 1 1Diversity* 1 1 2 2 1MIMO* 1 2 2 2 2* Not supported in this release.
Overview of RF Modules for Prism Remote Units  Page 18 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012PrismRemoteUnitDual‐Slot40WRFModulesTheFlexWavePRUDual‐Slot40WRFModule(Figure2)isdesignedforAWSandPCSfrequencies.ThePrismRemote40WRFModulecomprises:•oneDART•twoPowerAmplifiers(PAs)•oneRemoteDARTInterface(RDI)board.ThePrismRemote40WRFDiversityModulecomprises:•twoDARTs•twoPowerAmplifiers(PAs)•twoRDIboards.NOTE: ThismanualdescribeshowtoinstallthePCS1900andAWS2100Non‐DiversityRFModules.Figure8.Dual-Slot 40W RF Module
Safety PrecautionsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 19TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.INSTALLTHERFMODULE(S)Thefollowing8sectionscomprise16stepsthatguideyouthroughtheinstallationofanRFModuleintoaPRUchassis.TheprocesstoinstallthefourdifferenttypesofRFModulesisbasicallythesame.NOTE: Inthefollowingsteps,theRFcablesandconnectorsarereferredtoasMODNTX0/RX0andasMODNTRX1whereNequalsA,B,C,orD.SafetyPrecautionsCAUTION! Thisisrestrictedaccessequipmentandonlyqualifiedservicepersonnelshouldserviceandoperatethisequipmentusingappropriatetools.CAUTION! Wetconditionsincreasethepotentialforreceivinganelectricalshockwheninstallingorusingelectrically‐poweredequipment.Topreventelectricalshock,neverinstalloruseelectricalequipmentinawetlocationorduringalightningstorm.CAUTION! Alwaysallowsufficientfiberlengthtopermitroutingofpatchcordsandpigtailswithoutseverebends.Fiberopticpatchcordsorpigtailsmaybepermanentlydamagedifbentorcurvedtoaradiusoflessthan2inches(5.1cm).CAUTION! ExteriorsurfacesofthePrismRemoteUnitmaybehot.Usecautionduringservicing.CAUTION! Servicepersonnelmustconfirmthattheperimetergasketanddoor‐to‐doorgasketsareinplacewhenclosingthePrismdoorsafterservicing.CAUTION! ThisequipmentusesaClass1LaseraccordingtoFDA/CDRHrules.Laserradiationcanseriouslydamagetheretinaoftheeye.Donotlookintotheendsofanyopticalfiber.Donotlookdirectlyintotheopticaltransceiverofanydigitalunitorexposuretolaserradiationmayresult.Anopticalpowermetershouldbeusedtoverifyactivefibers.AprotectivecaporhoodMUSTbeimmediatelyplacedoveranyradiatingtransceiveroropticalfiberconnectortoavoidthepotentialofdangerousamountsofradiationexposure.Thispracticealsopreventsdirtparticlesfromenteringtheadapterorconnector.CAUTION! ThissystemisanRFTransmitterandcontinuouslyemitsRFenergy.Maintain3foot(91.4cm)minimumclearancefromtheantennawhilethesystemisoperating.Whereverpossible,shutdowntheRANbeforeservicingtheantenna.
Install the RF Module(s)  Page 20 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012GuardAgainstDamagefromElectro‐StaticDischargeCAUTION! Electro‐StaticDischarge(ESD)candamageelectroniccomponents.TopreventESDdamage,alwayswearanESDwriststrapwhenworkingwiththeIRUorwhenhandlinganyofitscomponents.ConnectthegroundwireontheESDwriststraptoanearthgroundsourcebeforetouchingtheIRUoranyofitscomponents.WearthewriststraptheentiretimethatyouworkwiththeIRUanditscomponents.CAUTION! PlacethePRismRFModulesinanti‐staticpackingmaterialwhentransportingorstoringthem.UnpackandInspecttheRFModule1UnpackandinspecttheRFModule.aInspecttheexterioroftheshippingcontainer(s)forevidenceofroughhandlingthatmayhavedamagedthecomponentsinthecontainer.bUnpackeachcontainerwhilecarefullycheckingthecontentsfordamageandverifywiththepackingslip.cIfdamageisfoundorpartsaremissing,fileaclaimwiththecommercialcarrierandnotifyTECustomerService(see“ContactingTEConnectivity”onpage43).Savethedamagedcartonsforinspectionbythecarrier.dSaveallshippingcontainersforuseiftheequipmentrequiresshipmentatafuturedate.CAUTION! HandletheRFModulewithcareduringinstallation.Beespeciallycarefultonotdamagethethermal‐interfacematerial(TIM),whichisattachedtotheLPA.IftheTIMisdamaged,theLPAcanoverheat.BeforeinstallingtheRFModule,checktoseeiftheheatsinkmaterialisgougedorcracked.IftheTIMisdamaged,donotinstalltheRFModuleandcontactTEConnectivityforassistance(see“ContactingTEConnectivity”onpage43forcontactinformation).CAUTION! Ifthethermal‐interfacematerialisdamaged,theinstallationanduseoftheRFModulemayvoidthewarrantyoftheRFModule.
Remove Release Liners from the RF ModuleFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 21TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.RemoveReleaseLinersfromtheRFModuleNOTE: ReleaseLinersarepresentonfrontandbackofnewmodules.2OpenthePRUenclosure.3Removereleaseliners,ifpresent,fromthethermalpadsontheRFModulepriortoinstallingthemoduleintothePRUchassis.CAUTION! Thethermalpadsareverysensitivetomishandling—donotnick,scratch,ordingthem.FormostRFModules,thethermalpadsarelocatedaslistedbelowandasshowninFigure9,whichshowsaDual‐Slot40WRFModule.•onelargepadonthebacksurfaceofeachLinearPowerAmplifier(LPA)•uptotwoonthefrontsurface(DARTs)•oneontheleftsideforthe(RDI)•oneonthevectormodulatorboardOne largethermal pad on each PA(bottom of the LPA)One thermal padfor the RDIOne thermal padfor each DARTOne thermal padfor each DARTOne thermal padfor RF PowerCombinerOne thermal padfor VectorModulator•oneontheRFpowercombiner.Figure9.Thermal Pads on a Dual-Slot 40W RF Module
Install the RF Module(s)  Page 22 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012ForHDMRFModules,thethermalpadsarelocatedaslistedbelowandasshowninFigure10.•onepadforeachRxandTxboard•onelargepadovertheDPM•oneforeachPowerAmplifier(PA),whichisonthebottomoftheHDMRFModule.DPM Thermal PadTx A Thermal PadTx B Thermal PadRx A Thermal PadRx B Thermal Pad2.9796 in2.9796 inNOTE: Tx and Rx cards are paired: Tx A ony pairs with Rx A and Tx B only pairs with Rx B.Figure10.Thermal Pads on an HDM RF Module
Dual-Slot Modules Only—Remove the Module Slot ShelfFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 23TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.Dual‐SlotModulesOnly—RemovetheModuleSlotShelf4ForDual‐SlotRFModulesonly.Use 9/64” Allen Wrench toremove the three module-shelf screwsRemove Module D Shelf forDual-Band Dual-Slot RF ModulesRemove Module B Shelf forDual-Slot 40W RF ModulesIfyouareinstallingaDual‐SlotRFModule,youmustremoveamoduleslotshelffromthePRUchassistoaccommodatethemodule’ssize.(Forfurtherinformation,Table6onpage11.)RemovetheshelfasappropriatefortheRFModule:•ForaDual‐Slot40WRFModule,removetheModuleBShelf.•ForaDual‐BandDual‐SlotRFModule,removeModuleDShelf.Toremovethemoduleshelf:aUsea9/64”Allen™wrenchtoremovethethreescrewsthatattachthemoduleshelftothePRUchassis,asshowninthefollowinggraphic.bDiscardorstorethemoduleshelfandfasteners.
Install the RF Module(s)  Page 24 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012InstalltheRFModuleintothePrismRemoteChassisRecommendation: InstallDual‐BandDual‐Slotmodulesinthetwoupper‐mostslotsofthePRU.Recommendation: InstallDual‐Slot40Wmodulesinthebottom‐mostslotsofthePRU.Recommendation: IfbothaDual‐SlotAWS210040WRFModuleandaDual‐SlotPCS190040WRFModuleareinstalledinaQuad‐BandPRU,installtheAWS2100Moduleinthelower‐mostslotofthePRU.5HoldtheRFModulesothattheDARTcard(s)faceawayfromthePRUandtheMountingHookistowardtheReceivingflangeonthePRUchassis.NOTE: AlwaysinstallRFModulesfromthebottomup.Donotskipaslot.6HoldingtheRFModuleata45°angleinrespecttotherearheatsink,restthebottomsurfaceofthemoduleontheRFModuleshelf,asshowninoneofthefollowinggraphics,andasapplicabletotheRFModule.•Single‐SlotRFModule:Figure11onpage25•HDMRFModule:Figure12onpage26•Dual‐BandDual‐SlotRFModule:Figure13onPage27•Dual‐Slot40WRFModule:Figure14onPage28.
RF MOD CRF MOD DSeRFModuleRF MOD ARF MOD BSingle-SlotRF ModuleHeat Sink Install the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 25TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.Figure11.Installing a Single-Slot RF Module
RF MOD CRF MOD DSeRFModuleRF MOD ARF MOD BHDM RF ModuleInstall the RF Module(s)  Page 26 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012Figure12.Installing an HDM RF Module
Installing a Dual-BandDual-Slot RF ModuleInstall the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 27TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.Figure13.Installing a Dual-Band Dual-Slot RF Module
Install the RF Module(s)  Page 28 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012Figure14.Installing a Dual-Slot 40W RF Module
Install the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 29TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.7AligntheMountingHookonthemodulewiththereceivingflangeonthePRUheatsink,andthenslidetheRFModuleintowardtheflangeuntilitcangonofurther.RF ModuleMounting hookChassisReceivingflange
Install the RF Module(s)  Page 30 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 20128PushtheleftedgeoftheRFModulebackandintothePRUchassisuntilitcangonofurther,asshowninthefollowinggraphics:•ForSingle‐SlotRFmodules,seeFigure15onpage30.•ForHDMRFmodules,seeFigure16onpage31.•ForDual‐SlotRFmodules,seeFigure17onpage32,whichusestheDual‐Slot40WRFModuleasanexample.CAUTION! MakesuretheRFModuleisseatedcorrectlyintheModuleshelf.IncorrectalignmentoftheRFModulecancausetheRFModuletofailduetooverheating.•ThefrontedgeoftheRFModuleshouldbeparallelwiththeshelfaboveit.•TheMountingHookontheRFModuleshouldbefullyengagedwiththeReceivingflangeonthePRUchassis.•IfyoulatercannotshutthePRUdoor,verifythattheRFModuleisinstalledcorrectly.Push the RF Moduleback into the chassisuntil it can go no further.Single-SlotRF ModuleFigure15.Seating a Single-Slot RF Module
Push the HDM RF Moduleback into the chassisuntil it can go no further.HDMRF ModuleInstall the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 31TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.Figure16.Seating an HDM RF Module
Push the RF Module backinto the chassis until it cango no further.Install the RF Module(s)  Page 32 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012Figure17.Seating a Dual-Slot RF ModuleSecureRFModuleLatches9TosecurethemodulelatchesontheleftsideoftheRFModule,dooneofthefollowing,asappropriatefortheRFModulebeinginstalled:•“ConnectLatchesonSingle‐SlotandHDMRFModules”onpage33•“ConnectLatchesonDual‐BandDual‐SlotRFModules”onpage34.
Secure RF Module LatchesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 33TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.ConnectLatchesonSingle‐SlotandHDMRFModulesForSingle‐SlotandHDMRFModules,securetwolatches,asshowninFigure18.Two latches on Single-SlotRF ModulesTwo latches onHDM RF ModulesFigure18.Latches on Single-Slot and HDM RF Modules
Install the RF Module(s)  Page 34 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012ConnectLatchesonDual‐BandDual‐SlotRFModulesForDual‐BandDual‐SlotRFModules,securefourlatches,asshowninFigure19.Four latches in aDual-Band Dual-SlotRF ModuleFigure19.Dual-Band Dual-Slot RF Module Latches
Secure RF Module LatchesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 35TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.LatchesonDual‐Slot40WRFModulesForDual‐Slot40WRFModules,securefourlatches,asshowninFigure20.Four latchesin a Dual-Slot40W RF ModuleFigure20.Dual-Slot 40W RF Module LatchesVerifythattheRFModuleMountingHookisEngaged10 VerifythattheRFModuleMountingHookisengagedcorrectlybypullingthemoduleawayfromtheheatsink.TheRFModuleshouldnotmove.IftheRFModulemovesduringthischeck,repeatStep6onpage24throughStep9.
Install the RF Module(s)  Page 36 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012ConnecttheRFModuleCables11 PositionthecablessothattheyareundertherightedgeoftheRFModule,pointingup.12 FollowtheruleslistedbelowwhenconnectingtheRFModulecables.•AlwaysprovidedateachRFModuleshelfarefivecables:–onePower(PWR)cable–twoRFcables(TX0/RX0)and(TX1/RX1)–twohigh‐speed‐datacables,whichinthisdocumentarereferredtoasLow‐VoltageDifferentialSignaling(LVDS)cables.•LVDScableslabeledPRIMandDIVshouldalwayseitherbeconnectedorstrainrelievedtoadjacentcables.Thisprotectsagainstthecablegettingcaughtinthechassisdoor.•MakesurethetwoLVDScablesarefullyseatedandlockedintotheirconnectors.•IfyouareinstallingamoduleintoaDiversityChassis,bothRFcableslabeledMODNTX0/RX0andMODNTX1/RX1willbepopulated.•ForDiversitymodules,allcablesaretobeconnected.•WhenyouorderaDualSuperDARTmodule,connectbothLVDScables(PRIMandDIV)andtheRFTX0/RX0cable.•Adheretoaminimumbendradiusof1‐inchforallRFcablesfromtheintegratedcableguidetothemodule.•Maintainadequatestrainreliefdistancesfromconnectionpointstothemodule.•WheninstallingDual‐SlotRFmodules:–TheupperRFModuleshelfwilleithernotbepresent(factoryinstalledmodule)orwillberemovedpriortoinstallation(fieldinstalledmodule).–ForDual‐Slotmodules,onlytheRFcablelabeledMODNTX0/RX0onthelowermoduleslotwillbeconnectedtothemoduleconnectorTX0/RX0.–TheMODNTX1/RX1cableshouldbesecuredtothecablebundleusingtheprovidedcabletie.–EnsurethattheMODNTX1/RX1cableandconnectoraresecuredsothattheywillnotbepinchedorpreventthePRUdoorfromclosing.–ThePower(PWR)cableandtwoLVDScablesoftheupperRFModuleslotwillnotbeused.ConnecttheRFcablelabeledMODNTX1/RX1totheconnectorlabeledN/Contheupperhalfofthedouble‐slotmodule.UseoneoftheprovidedcabletiestosecuretheMODNTX0/RX0RFcable,bothLVDScablesandthePower(PWR)cabletotheRFcablelabeledMODNTX1/RX1,ensuringthatthecablebundlewillnotbepinchedorpreventthePRUdoorfromclosing.
Connect the RF Module CablesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 37TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.13 Workingfromthebottomconnectorup,connecttheRFModulecables.aIfthisisaDiversitychassis:•ForSingle‐Slotinstallationsonly—connecttheRFDiversitycablelabeledMODNTX1/RX1totheTX1/RX1connectorandturnthethumbscrewtosecurethecabletothechassis.•ForDual‐Slotinstallationsonly—theTX1/RX1connectorispre‐populated.DonotremovethefactoryconnectiontoRX1.Instead,securetheMODNTX1/RX1cabletothecablebundleusingoneoftheprovidedcableties.EnsurethattheMODNTX1/RX1cableandconnectoraresecuredsotheywillnotbepinchedorpreventthedoorfromclosing.bConnecttheRFcablelabeledMODNTX0/RX0totheTX0/RX0connectorandturnthethumbscrewtosecurethecabletothechassis.cForSingle‐Slotinstallationsonly—connecttheMODNDIVLVDScabletotheDIVconnector.ThisconnectstheRemoteUnitSeRF(RSI)interfaceboardtotheDiversityDART.MakesurethatyouheartheLVDScablelockintotheDIVconnectorwithanaudibleclick.GiveagentletugontheLVDScable—ifyoudonotpresstheunlocklever,theLVDScableshouldnotcomeoutoftheconnector.NOTE: AlwaysconnecttheDiversityLVDScable.ThispreventsthecablefromgettingcaughtbetweenthechassisdoorandtheRFModule.dConnecttheMODNPRIMLVDScabletothePRIMconnector.ThisconnectstheRSItothePrimaryDART.eConnectthePowercabletothePWRconnector.ThisconnectstheRFModuletotheDCpowerconnection.fForDual‐Slotinstallationsonly—thePower(PWR)cableandtwoLVDScablesoftheupperRFModuleshelfarenotbeused.ConnecttheRFcablelabeledMODNTX1/RX1oftheupperRFModuleshelftotheconnectorlabeledN/ContheupperhalfoftheDual‐Slotmodule.UseoneoftheprovidedcabletiestosecuretheMODNTX0/RX0RFcable,bothLVDScablesandthePower(PWR)cabletotheRFcablelabeledMODNTX1/RX1,ensuringthatthecablebundlewillnotbepinchedorpreventthePRUdoorfromclosing.RefertothegraphicthatcorrespondstotheRFModulebeinginstalled:•Single‐SlotRFModule:Figure21onPage38•HDMRFModule:Figure22onpage39•Dual‐BandDual‐SlotRFModule:Figure23onPage40•Dual‐Slot40WRFModule:Figure24onPage41.
MOD AMOD DMOD CMOD BSeRFModuleTX0/RX0RX1DIVPRIMPWRNote routing ofhigh-speed cablesNote bendradii ≥ 1-inchEdge of Connector Interface PanelCable connections for a Single-Slot RF ModuleInstall the RF Module(s)  Page 38 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012Figure21.Cable Connections for Single-Slot RF Modules
Cable connections for an HDM RF ModuleTX0/RX0TX1/RX1POWERDATA 1 (DIV)DATA 0 (PRIM)Connect the RF Module CablesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 39TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.Figure22.Cable Connections for HDM RF Modules
Cable Connections for a Dual-Slot RF ModuleTie wrapFactory-installedRX1 cableTwo N-TypeRF connectorsTwo N-TypeRF connectorsInstall the RF Module(s)  Page 40 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012Figure23.Cable Connections for Dual-Band Dual-Slot RF Modules
Tie wrap around factory-installedRX1 cableKeep cable bendsbehind the edge of the Connector Interface PanelConnect the RF Module CablesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 41TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.Figure24.Cable Connections for Dual-Slot 40W RF Modules14 EnsurethatallcablebendsarebelowthetopedgeoftheConnectorInterfacePanelasindicatedbythedashedlineintheprecedingfigure.FailuretocorrectlypositionthecablescouldinhibitclosingthePRUdoor,whichcanresultindamagetothecables.
Install the RF Module(s)  Page 42 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012PowerontheRFModule15 FollowtheruleslistedbelowtotogglethePowerswitchthatcorrespondstotheRFModuletoitsONposition.•ForDual‐SlotRFModules,usethePowerswitchforthelowermodule.Forexample,topowerupaDual‐SlotRFModuleincombinedslotsC+DinaQuad‐Bandchassis,turnONDCPowerswitchforModC;leavetheDCPowerswitchforModDOFF.•ADual‐Slot40WRFModuleusesthePowerSuppliesinbothslots.IftheDual‐Slot40WRFModuleisinstalledinslotsC+D,turnONthePowerswitchforModCandModD.MOD ASeRFModuleAC Powerswitch forRemotechassisDC Power switch for Mod ADC Power switch for Mod BDC Power switch for Mod CDC Power switch for Mod DMOD BMOD CMOD D16 RepeatStep1throughStep15toinstallotherRFModules.
Contacting TE Connectivity by TelephoneFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 43TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.CONTACTINGTECONNECTIVITYContactingTEConnectivitybyTelephoneSalesAsia Pacific +65-6294-9948France 0800 914032Germany 0180 2232923Italy 0800 782374Spain 900 983291United Kingdom 0800 960236USA or Canada 1-800-366-3891Extension 73000Connectivity Extension 73475Wireless Extension 73476Technical SupportUSA or Canada 1-800-530-9960Elsewhere +1-952-917-0761OnlineAccesstoTEConnectivityCustomer Portalhttps://www.te.com/commerce/uso/myaccount.doTechnical Support for Wireless Productshttp://www.te.com/WirelessSupport
https://www.te.com/commerce/uso/myaccount.do">
Contacting TE Connectivity  Page 44 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012

Navigation menu