ADC Telecommunications PSMAWS2D FWP-A4MT000MOD User Manual

ADC Telecommunications Inc FWP-A4MT000MOD

User Manual

Download: ADC Telecommunications PSMAWS2D FWP-A4MT000MOD User Manual
Mirror Download [FCC.gov]ADC Telecommunications PSMAWS2D FWP-A4MT000MOD User Manual
Document ID2048607
Application IDaAOSxbgMdb2xoyJUM8z9/w==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize305.19kB (3814843 bits)
Date Submitted2013-08-20 00:00:00
Date Available2013-08-21 00:00:00
Creation Date2012-11-13 09:48:53
Producing SoftwareAcrobat Distiller 10.1.4 (Windows)
Document Lastmod2012-11-13 10:15:21
Document TitleFlexWave Prism RF Modules for Prism remote Units Installation Guide
Document CreatorFrameMaker 10.0.2
Document Author: te106558

FlexWave Prism®
RF Modules for Prism Remote Units
Installation Guide
TECP-77-141  Issue 2  August 2012
Single-Slot RF Module
Dual-Slot 40W RF Module
300001744178 Rev B
Dual-Band Dual-Slot RF Module
HDM RF Module
Copyright
© 2012 TE Connectivity, Inc. All Rights Reserved.
Information contained in this document is company private to TE Connectivity Ltd., and shall not be modified,
used, copied, reproduced or disclosed in whole or in part without the written consent of TE.
Trademark Information
FlexWave, FlexWave Prism, InterReach Spectrum, InterReach Unison, Universal Radio Head, TE
Connectivity, and TE connectivity (logo) are trademarks.
All other logos, products and/or company names referred to herein might be trademarks of their respective
owners.
Disclaimer of Liability
Contents herein are current as of the date of publication. TE reserves the right to change the contents without
prior notice. Should the content of printed user documentation shipped with product differ from documentation
provided on a product CD (inclusive of the associated Help modules), the printed user documentation
supersedes the documentation on the product CD. In no event shall TE be liable for any damages resulting
from loss of data, loss of use, or loss of profits, and TE further disclaims any and all liability for indirect,
incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products,
publications and services during and after the warranty period.
Specific Disclaimer for High-Risk Activities
This Product is not specifically designed, manufactured, tested or intended for use in high-risk activities
including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft
navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear
facility. TE (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of
fitness for such purposes or any other purposes.
TABLE OF CONTENTS
Topics
Page
Preface .................................................................................................................................................................2
Revision History...................................................................................................................................................... 2
FlexWave Prism User Documentation.................................................................................................................... 2
Accessing User Documentation on the Customer Portal ...................................................................................................3
Document Cautions and Notes...........................................................................................................................................3
Standards Certification........................................................................................................................................... 4
Overview of RF Modules for Prism Remote Units..................................................................................................5
RF Module Components......................................................................................................................................... 8
Duplexer and Low Noise Amplifier .....................................................................................................................................9
Linear Power Amplifiers .....................................................................................................................................................9
Digital Processing Module ................................................................................................................................................10
RF Module Cables .............................................................................................................................................................10
RF Module Cables for Single‐Card, Dual‐Card, and HDM RF Modules................................................... 10
RF Module Cables for Dual‐Slot Installations......................................................................................... 12
Prism Remote Unit RF Group Assignments ......................................................................................................................13
PRU RF Module Types .......................................................................................................................................... 16
Prism Remote Unit Single‐ and Dual‐Card RF Modules ....................................................................................................16
Prism Remote Unit HDM RF Modules ..............................................................................................................................17
Prism Remote Unit Dual‐Slot 40W RF Modules................................................................................................................18
Install the RF Module(s)......................................................................................................................................19
Safety Precautions................................................................................................................................................ 19
Guard Against Damage from Electro‐Static Discharge......................................................................................... 20
Unpack and Inspect the RF Module ..................................................................................................................... 20
Remove Release Liners from the RF Module ....................................................................................................... 21
Dual‐Slot Modules Only—Remove the Module Slot Shelf ................................................................................... 23
Install the RF Module into the Prism Remote Chassis.......................................................................................... 24
Secure RF Module Latches ................................................................................................................................... 32
Connect Latches on Single‐Slot and HDM RF Modules ....................................................................................................33
Connect Latches on Dual‐Band Dual‐Slot RF Modules .....................................................................................................34
Latches on Dual‐Slot 40W RF Modules.............................................................................................................................35
Verify that the RF Module Mounting Hook is Engaged ....................................................................................................35
Connect the RF Module Cables ............................................................................................................................ 36
Power on the RF Module...................................................................................................................................... 42
Contacting TE Connectivity .................................................................................................................................43
Contacting TE Connectivity by Telephone............................................................................................................ 43
Online Access to TE Connectivity ......................................................................................................................... 43
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 1
©2012 TE Connectivity Ltd.
Preface
PREFACE
This manual provides the information you need to install TE Connectivity FlexWave Prism® RF
Modules into a Prism Remote Unit (PRU). Installation instructions are provided for the following
Prism Remote Unit RF Modules:
•
Single‐Slot RF Modules, which includes the HDM RF Modules
•
Dual‐Slot RF Modules
– Dual‐Card RF Modules
–
40W RF Modules.
NOTE:
This installation guide documents the RF Modules that are compatible with the FlexWave Prism
Remote Unit, which is designed for outdoor use. For information on the RF Modules designed for
use with the FlexWave Prism Indoor Remote Units (IRUs), see the FlexWave Prism Indoor Remote
Unit Installation Guide (TECP‐77‐197).
Revision History
Table 1.
Revision History
Issue Document Date
Technical Updates
April 2012
Original
December 2012
• Updated Table 2 on page 3 with new Prism user documentation list.
• Updated Table 3 on page 7 to add new RF Modules.
• Removed the Specifications section, which included the RF and Optical Specifications and the
Frequency and Composite Output Power at Antenna Port (dBm) for Prism Remote Units tables; to
access these performance specifications, refer to the Flexwave Prism Performance Specifications
(TECP-77-201).
• Updated “Contacting TE Connectivity” on page 43.
FlexWave Prism User Documentation
FlexWave Prism user documentation is intended for system administrators, engineers and
installers responsible for planning, administering, configuring, and maintaining FlexWave Prism
systems. Table 2 on page 3 lists the manuals that correspond to the features of the FlexWave
Prism RF Modules described in this installation guide.
Page 2
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
FlexWave Prism User Documentation
Table 2.
FlexWave Prism User Documentation
Title
Catalog Number
Element Management System 7.3 and 7.4 User Guide
Host Unit II Installation Guide
Host Unit Expansion Unit Installation Guide
TECP-77-212
Host Unit II and Host Unit Expansion Unit Module Replacement Guide
Prism Remote Unit Installation Guide
RF Modules for Prism Remote Units Installation Guide (1)
Indoor Remote Unit Installation Guide
OADM Splice Box Installation Guide
TECP-77-207
Coarse Wavelength Division Multiplexer User Guide
TECP-77-209
Flexwave Prism Performance Specifications
TECP-77-201
TECP-77-206
TECP-77-202
TECP-77-142
TECP-77-141
TECP-77-197
TECP-77-208
The Prism Remote RF Modules and Remote Mounting Kit are designed for use only in the Prism Remote
Unit (PRU). The IRU RF Modules and mounting options are described in the FlexWave Prism Indoor
Remote Unit Installation Guide (TECP-77-197).
Accessing User Documentation on the Customer Portal
Click on the following URL link or enter the URL into your web browser, and then press Enter
on your keyboard:
http://www.adc.com/Americas/en_US/1268116693520
NOTE:
Access to the Customer Portal requires a user account and password. If you do not have an
account, click on the registration link on the Log In page.
On the Customer Portal Home page, click Manuals & Spec Sheets.
On the Manuals & Spec Sheets page, click on the title of the manual that you wish to open or
download.
Document Cautions and Notes
Two types of messages, identified below, appear in the text:
CAUTION!
Caution text indicates operations or steps that could cause personal injury, induce a safety
problem in a managed device, destroy or corrupt information, or interrupt or stop services.
NOTE:
Note text contains information about special circumstances.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 3
© 2012 TE Connectivity Ltd.
Preface
Standards Certification
FCC: This equipment complies with the applicable sections of Title 47 CFR Part 15 (Host Unit), Part
22 (800 MHz Cellular), Part 24 (1900 MHz ‐ PCS), Part 90 (800/900 ‐ SMR), and Part 27 (2100
MHz ‐ AWS) & (700 MHz ‐LTE).
IC: This equipment complies with the applicable sections of RSS‐131. The term “IC:” before the
radio certification number only signifies that Industry Canada Technical Specifications were met.
The Manufacturer's rated output power of this equipment is for single carrier operation. For
situations when multiple carrier signals are present, the rating would have to be reduced by 3.5
dB, especially where the output signal is re‐radiated and can cause interference to adjacent band
users. This power reduction is to be by means of input power or gain reduction and not by an
attenuator at the output of the device.
Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum
composite output from the antenna cannot exceed 1000 Watts ERP (LTE, Cellular and SMR), the
antenna cannot exceed 1640 Watts EIRP (PCS and AWS), and the antenna must be permanently
installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons.
UL/CUL: This will be installed in a restricted access location. This equipment complies with Type
4, per UL and CUL 50, Standard for Enclosures for Electrical Equipment. This equipment provides
the degree of protection specified by IP66 as defined in IEC Publication 529.
FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules. This product
conforms to all applicable standards of 21 CFR Part 1040.
Caution: Modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
EU Harmonized Standards: Meets essential requirements of R&TTE 1999/5/EC.
•
Article 3.1a—The protection of the health and the safety of the user and any other person,
including the objectives with respect to safety requirements contained in Directive
2006/95/EC, but with no voltage limit applying.
•
Article 3.1b—The protection requirements with respect to electromagnetic compatibility
contained in Directive 2004/108/EC.
•
Article 3.2—In addition, radio equipment shall be so constructed that it effectively uses
the spectrum allocated to terrestrial/space radio communication and orbital resources so
as to avoid harmful interference.
EMC Standards: EN 55022 and EN55024 (CE marked)
Safety Standards:
•
IEC 60950‐1, First Edition (CE marked)
•
UL 60950‐1 (File number E174166) (USA and Canada)
Page 4
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Standards Certification
OVERVIEW OF RF MODULES FOR PRISM REMOTE UNITS
Figure 1 illustrates the Prism Remote Unit (PRU), which controls RF emissions, interfaces with
the FlexWave Host.
Single-Band
Remote
Dual-Band
Remote
Figure 1. Prism
Tri-Band
Remote
Quad-Band
Remote
Remote Units
The PRU has from one to four RF Module slots, depending on the PRU model. That is, the
Single‐Band PRU has one RF Module slot, and the Quad‐Band PRU has four RF Module slots. A PRU
can support up to four RF Modules.
The function of the PRU RF Modules on the Forward Path is to:
•
convert the digitized RF transported from the Host to Analog RF
•
amplify the Analog RF signal
•
provide signal filtering.
The function of the PRU RF Modules on the Reverse Path is to:
•
convert the Analog RF from the handset to Digital RF for transport to the Host
•
provide signal filtering.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 5
© 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units
Each RF Module can support any of the following DART combinations:
•
one Classic DART or one Single SuperDART
•
two Classic DARTs
•
two Single SuperDARTs
•
one Dual SuperDART
•
one or two sets of Tx or Rx Boards (HDM)
– HDM‐850 has one set
– HDM‐700 has two sets.
Each RF Module will have up to two 6‐Timeslot DARTs or one 12‐Timeslot DARTs per RF Module.
The RF Modules are field replaceable, but cannot be serviced in the field.
Table 3 on page 7 lists the Prism Remote Unit RF Modules that are supported in this installation
guide.
Page 6
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Standards Certification
Table 3.
Supported FlexWave Prism RF Modules for Prism Remote Units (PRUs)
Catalog Number
Description
FWP-K2 2600 0MOD
10W 900 P-GSM Module, Diversity, SGL SD
FWP-K2 1600 0MOD
10w 900 P-GSM Module, Non-Diversity, SGL SD
FWP-F 2160 00MOD
10W APAC EGSM (885-915) MODULE, SGL SD
FWP-6 226 000M OD
10W, EGSM 900, DIVERSITY, SGL SD
FWP-6 216 000M OD
10W, EGSM 900, NON-DIVERSITY, SGL SD
FWP-9 416 D00 MOD
20W 2100 UMTS MODULE, DIV Ready, SGL SD
FWP-L 416 000M OD
20W 700 Lower ABC MODULE, NON-DIVERSITY, SGL SD
FWP-A 426 000 MOD
20W AWS MODULE, DIVERSITY, SGL SD
FWP-A 416 000 MOD
20W AWS MODULE, NON-DIVERSITY, SGL SD
FWP-8 426 000M OD
20W PCS MODULE, DIVERSITY, SGL SD
FWP-8 416 000M OD
20W PCS MODULE, NON-DIVERSITY, SGL SD
FWP-A 41S 000 MOD
20W RF Module, AWS 2100 12S Enclosure
FWP-A 420 000 MOD
20W RF Module, AWS 2100 Diversity Enclosure
FWP-A 410 000 MOD
20W RF Module, AWS 2100 Non-Diversity Enclosure
FWP-8 41S 000 MOD
20W RF Module, PCS 1900 12S Enclosure
FWP-8 420 000M OD
20W RF Module, PCS 1900 Diversity Enclosure
FWP-8 410 000M OD
20W RF Module, PCS 1900 Non-Diversity Enclosure
FWP-B42 000 0MOD
20W WIDEBAND CELL MODULE, DIVERSITY, CLASSIC
FWP-B41 000 0MOD
20W WIDEBAND CELL MODULE, NON-DIVERSITY, Classic
FWP-7 426 000M OD
20W, GSM 1800, DIVERSITY, SGL SD
FWP-7 41S 000 MOD
20W, GSM 1800, NON-DIVERSITY, DL SD
FWP-7 416 000M OD
20W, GSM 1800, NON-DIVERSITY, SGL SD
FWP-9 426 000M OD
20W, UMTS 2100, DIVERSITY, SGL SD
FWP-9 41S 000 MOD
20W, UMTS 2100, NON-DIVERSITY, DL SD
FWP-9 416 000M OD
20W, UMTS 2100, NON-DIVERSITY, SGL SD
FWP-U81 6100 MOD
40W 700 Upper C MODULE, NON-DIVERSITY, SGL SD (SGL-SLOT)
FWP-A 810 000 MOD
40W AWS MODULE, NON-DIVERSITY, CLASSIC
FWP-A 816 000 MOD
40W AWS MODULE, NON-DIVERSITY, SGL SD (DUAL-SLOT)
FWP-8 810 000M OD
40W PCS MODULE, NON-DIVERSITY, CLASSIC (DUAL-SLOT)
FWP-8 816 000M OD
40W PCS MODULE, NON-DIVERSITY, SGL SD (DUAL-SLOT)
FWP-B81 010 0MOD
40W WIDEBAND CELL MODULE, NON-DIVERSITY, (SGL-SLOT)
FWP-4 210 000M OD
6.5W 800 SMR MODULE, NON-DIVERSITY, CLASSIC
FWP-D 210 000 MOD
6.5W 800/900 ESMR MODULE, NON-DIVERSITY, CLASSIC
FWP-I 2100 00MOD
6.5W APAC iDEN Module, Non-Diversity, Classic (Extended 1 MHz)
FWP-U41 6000 MOD
700 LTE, UPPER C, 20W MODULE, SISO, SGL SD
FWP-L 4MT 000 MOD
DUAL 20W 700 LOWER ABC MODULE, MIMO
FWP-U4M T000 MOD
DUAL 20W 700 UPPER C MODULE, MIMO
FWP-C4M T000 MOD
DUAL 20W 850/1900 RF MODULE, (SGL BAY)
FWP-A 4MT 000 MOD
DUAL 20W 2100 RF MODULE, MIMO, (SGL BAY)
FWP-A 81T 000 MOD
40W AWS MODULE, NON-DIVERSITY, SGL SD (SGL-Bay)
FWP-8 81T 000M OD
PRISM, 40W PCS MODULE, NON-DIVERSITY, SGL SD (SGL BAY)
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 7
© 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units
RF Module Components
Figure 2 shows typical RF Module components, using the Single‐Slot RF Module as an example.
DARTs
Mounting
latch
Duplexer
Power Amplifier (PA)
Mounting hook
Figure 2. PRU
Single-Slot RF Module Components
Figure 3 shows the components of an HDM RF Module.
Tx and Rx Cards
Duplexers
Power Amplifier
Mounting hook
Mounting latch
Figure 3. HDM
Page 8
© 2012 TE Connectivity Ltd
RF Module Components
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
RF Module Components
Duplexer and Low Noise Amplifier
The RF Module provides the PRU with an internal Duplexer that is optimized to provide the
desired RF band‐pass filtering and in‐band equipment isolation between FWD and REV paths.
The Duplexer provides the filtering necessary to the transmit and receive paths to the connected
antenna.
The Duplexer for the Prism Remote Unit Single‐ and Dual‐Card RF Modules and the Dual‐Slot 40W
RF Modules contains up to two REV path Low Noise Amplifiers (LNA for PRI and/or SEC reverse
paths). Each LNA provides the Prism reverse path with nominal 30dB REV gain and system NF of
5dB per RX path.
The Duplexer for an HDM RF Module does not have a Low Noise Amplifier.
Duplexers are not field serviceable.
Linear Power Amplifiers
The Linear Power Amplifier (LPA) is a high quality broadband RF amplifier used for achieving
Prism product‐rated power for the PRU Tx forward path spectrum RF. The PAs are pass‐band
specific, with the maximum composite Tx power levels, and >10dB instantaneous peak power
rating listed in:
•
Table 4 for Single‐Card, Dual‐Card, and HDM RF Modules
•
Table 5 on page 10 for Dual‐Slot 40W RF Modules.
The LPA is housed within the RF Module, and is not field serviceable.
Table 4.
LPA Maximum Composite Tx Power Levels for Single‐Card, Dual‐Card, and HDM RF Modules
Passband
Maximum Watts
dBm
Instantaneous
Bandwidth
(MHz)
AWS 2100
+43
20
45
Cellular 850
+43
20
25
+46
40
25
EGSM 900
+40
10
35
DCS 1800
+42
15.8
75
LTE 700 Lower ABC
+43
20
18
+46
40
18
+43
20
10
LTE 700 Upper C
+46
40
10
PCS 1900
+43
20
70
PGSM 900
+40
10
25
SMR 800
+38
6.5
18
SMR 900
+38
6.5
UMTS 2100
+42
15.8
60
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 9
© 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units
Table 5.
LPA Maximum Composite Tx Power Levels for Dual‐Slot 40W RF Modules
Passband
Maximum Watts Instantaneous
dBm
Bandwidth (MHz)
PCS 1900
+46
40
70
AWS 2100
+46
40
45
Digital Processing Module
The Digital Processing Module (DPM) is found only in the HDM RF Modules. The DPM provides
the primary processing and logic functions for the HDM RF Module. It also provides the primary
power interface for the HDM RF Module, and conversion of the native 28VDC voltage to lower
voltages as necessary for functionality.
The DPM has a Transmit (Tx) Board and a Receive (Rx) Board:
•
Tx Board—provides band specific filtering for the intended Transmit path.
•
Rx Board—provides band specific filtering for the intended Receive path.
RF Module Cables
The RF Module cables that are pre‐installed in the PRU connect to the corresponding connectors
on the RF Module. The RF Module cables correlate to the antenna connectors on the bottom of the
PRU chassis.
RF Module Cables for Single‐Card, Dual‐Card, and HDM RF Modules
The RF cable and connector labels also correspond to the RF Module slots in the PRU chassis,
where MOD A is the bottom slot and MOD D is the top slot. In the installation steps, the RF cables
and connectors are referred to as MOD N TX0/RX0 and as MOD N TRX1 where N equals A, B, C, or D.
The cables and connectors have corresponding labels as shown in Table 6 for Single‐Card,
Dual‐Card, and HDM RF Modules.
Page 10
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
RF Module Components
Table 6.
RF Module
Cable,
RF Module
Connector,
and Remote
Antenna
Connector
Label
RF Antenna Labels for Single‐Card, Dual‐Card, and HDM RF Modules—From Top of Chassis Down
Dual-Slot Remote Unit RF Module Slot
Designations
Function
Mod D
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module D
Mod D
TX1/RX1
Diversity receive for RF power from the
antenna for RF Module D
Mod C
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module C
Mod C
TX1/RX1
Diversity receive for RF power from the
antenna for RF Module C
Mod B
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module B
Mod B
TX1/RX1
Diversity receive for RF power from the
antenna for RF Module B
Mod A
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module A
Mod A
TX1/RX1
Diversity receive for RF power from the
antenna for RF Module A
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Single-Slot
Remote Unit RF
Module Slot
Designations
Dual-Band
Tri-Band
Quad-Band
MOD D
N/A
N/A
MOD C
MOD C
N/A
MOD B
MOD B
MOD A
MOD A
MOD B
MOD A
MOD A
Page 11
© 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units
RF Module Cables for Dual‐Slot Installations
For Dual‐Slot installations, the RF cables and connectors are labeled as MOD N TX0/RX0 and MOD N
TX1/RX1, where N refers to the bottom slot of the double‐slot installation. For example, for a
Dual‐Slot installation in a Quad‐Band chassis, the RF cables and connectors are labeled as MOD C
TX0/RX0 and MOD C TX1/RX1.
The cables and connectors have corresponding labels as shown in Table 7 on page 12 for
Dual‐Slot 40W RF Modules.
Table 7.
RF Module
Cable,
RF Module
Connector,
and Remote
Antenna
Connector
Labels
RF Antenna Labels for Dual‐Slot 40W RF Modules (Top of Chassis Down)
Slots for 40W RF Modules (a) (b)
Function
Mod D
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module D
Mod D RX1
Diversity receive for RF power from the
antenna for RF Module D
Mod C
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module C
Mod C RX1
Diversity receive for RF power from the
antenna for RF Module C
Mod B
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module B
Mod B RX1
Diversity receive for RF power from the
antenna for RF Module B
Mod A
TX0/RX0
Transmit RF power and primary receive
to/from the antenna for RF Module A
Mod A RX1
Diversity receive for RF power from the
antenna for RF Module A
Dual-Band
Tri-Band
Quad-Band
N/A
N/A
Slots C and D
N/A
N/A
Slots A and B
Slots A and B
Slots A and B
(a)
N/A indicates that the slot cannot be used for a Dual-Slot 40W RF Module
(b)
Install the Dual-Slot 40W RF Module in the lower-most slot in the chassis. If, however, if two Dual-SLot
40W RF Modules are present, install the 2100 Module in the lower-most slot and the 1900 Module in the
upper-most slot.
Page 12
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
RF Module Components
Prism Remote Unit RF Group Assignments
A Prism Remote Unit (PRU) comprises from one to four RF Module slots. Figure 4
illustrates the numbering of RF Module slots and DARTs.
Prism Quad-Band Remote Unit
with Single-Card RF Modules
DART 7
Group D
DART 8
DART 5
Group C
DART 6
DART 3
Group B
DART 4
DART 1
Group A
DART 2
SeRF Module
Figure 4. DART RF Groups in a Prism Remote Unit (PRU)
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 13
© 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units
Table 8 lists how the FlexWave Prism EMS references the RF group assignments
and corresponding components of each RF Module.
Table 8.
Remote Unit RF Group Assignments (from Top/Down)
LNA Number
Physical
RF Slot
RF
Group
DART
Number
Primary Diversity
LPA
Number
for Single
LPA
LPA
Number
for Dual
LPAs
Power
Detector
Number
for Single
PD
Power
Detector
Number
for Dual
PDs
SeRF Board
NOTE:
In a dual-LPA system, the Configure Remote Forward Gain page shows two values for the LPA
status, one for each LPA. Changing the LPA Mode or resetting the LPA applies to both LPAs at the
same time.
CAUTION!
Should your system experience an LPA problem, refer to Table 8 to ensure that you apply new
settings or troubleshoot the correct RF Module.
CAUTION!
If you use a customized SNMP polling for system status, you must change your LPA indexing
scheme.
Page 14
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
RF Module Components
The Dual‐Slot 40W RF Module occupies two slots in a Prism Remote. Figure 5 shows the main
components in a Prism enclosure, with a 40W RF Module occupying Slots A and B. The controlling
DART will always be in the upper slot (B or D), and the second LPA is always in the lower slot (A
or C).
Fans
Slot D (empty for future use)
Slot C (empty for future use)
Dual-slot 40W RF Module
in Slot B (upper slot) and
Slot A (lower slot) with the
controlling DART in Slot B
and the second DART in Slot A
SeRF Module and Power supplies
Four DC power switches
AC power switch
Connectivity panel with Status LED
Figure 5. Dual-Slot
40W RF Module in a Quad-Band Prism Remote
NOTE:
If a Dual‐Slot 40W RF Module AWS 2100 and a Dual‐Slot 40W RF Module PCS 1900 are both
installed in a Quad‐Band Remote, it is recommended that the PCS 1900 be installed in
upper‐most slot, and the AWS 2100 be installed in the lower‐most slot.
NOTE:
To accommodate two‐slot modules, you need to remove a module slot shelf as described in
“Dual‐Slot Modules Only—Remove the Module Slot Shelf” on page 23.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 15
© 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units
PRU RF Module Types
The PRU RF Modules are available in the following formats, and as described in the following
sections:
•
“Prism Remote Unit Single‐ and Dual‐Card RF Modules” on page 16
•
“Prism Remote Unit HDM RF Modules” on page 17
•
“Prism Remote Unit Dual‐Slot 40W RF Modules” on page 18.
Prism Remote Unit Single‐ and Dual‐Card RF Modules
Figure 6 shows examples of PRU Single‐ and Dual‐Slot RF Modules, both of which have two
DARTs. A PRU Single‐ and Dual‐Card RF Module comprises:
•
one DART
•
one Duplexer with one or two internal Low Noise Amplifiers (LNAs)
•
one Linear Power Amplifier (LPA)
•
one Remote DART Interface (RDI) board.
Single-Slot Dual-Card RF Module
Dual-Band Dual-Slot RF Module
Figure 6. Single-
Page 16
© 2012 TE Connectivity Ltd
and Dual-Slot RF Modules
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
PRU RF Module Types
Prism Remote Unit HDM RF Modules
PRU HDM RF Modules (Figure 7) are designed for 850 Cell frequencies. The initial release of the
HDM RF Module is a Single Input Single Output (SISO) Configuration that
•
interfaces one Host DART—either Classic or SuperDART
•
supports two non‐contiguous RF slices up to 25MHz total bandwidth—SuperDART only
•
supports up to 40W RF output power.
Figure 7. HDM
RF Module
The components of a PRU HDM RF Module is dependent on the module type, as listed in Table 9.
Table 9.
Components of PRU HDM RF Modules
RF Module Type DPM LPA
Duplexer Rx Card Tx Card
SISO
Diversity*
MIMO*
* Not supported in this release.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 17
© 2012 TE Connectivity Ltd.
Overview of RF Modules for Prism Remote Units
Prism Remote Unit Dual‐Slot 40W RF Modules
The FlexWave PRU Dual‐Slot 40W RF Module (Figure 2) is designed for AWS and PCS frequencies.
The Prism Remote 40W RF Module comprises:
•
one DART
•
two Power Amplifiers (PAs)
•
one Remote DART Interface (RDI) board.
The Prism Remote 40W RF Diversity Module comprises:
•
two DARTs
•
two Power Amplifiers (PAs)
•
two RDI boards.
NOTE:
This manual describes how to install the PCS 1900 and AWS 2100 Non‐Diversity RF Modules.
Figure 8. Dual-Slot
Page 18
© 2012 TE Connectivity Ltd
40W RF Module
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Safety Precautions
INSTALL THE RF MODULE(S)
The following 8 sections comprise 16 steps that guide you through the installation of an RF
Module into a PRU chassis. The process to install the four different types of RF Modules is
basically the same.
NOTE:
In the following steps, the RF cables and connectors are referred to as MOD N TX0/RX0 and as
MOD N TRX1 where N equals A, B, C, or D.
Safety Precautions
CAUTION!
This is restricted access equipment and only qualified service personnel should service and
operate this equipment using appropriate tools.
CAUTION!
Wet conditions increase the potential for receiving an electrical shock when installing or using
electrically‐powered equipment. To prevent electrical shock, never install or use electrical
equipment in a wet location or during a lightning storm.
CAUTION!
Always allow sufficient fiber length to permit routing of patch cords and pigtails without severe
bends. Fiber optic patch cords or pigtails may be permanently damaged if bent or curved to a
radius of less than 2 inches (5.1 cm).
CAUTION!
Exterior surfaces of the Prism Remote Unit may be hot. Use caution during servicing.
CAUTION!
Service personnel must confirm that the perimeter gasket and door‐to‐door gaskets are in place
when closing the Prism doors after servicing.
CAUTION!
This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously
damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly
into the optical transceiver of any digital unit or exposure to laser radiation may result. An
optical power meter should be used to verify active fibers. A protective cap or hood MUST be
immediately placed over any radiating transceiver or optical fiber connector to avoid the
potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles
from entering the adapter or connector.
CAUTION!
This system is an RF Transmitter and continuously emits RF energy. Maintain 3 foot (91.4 cm)
minimum clearance from the antenna while the system is operating. Wherever possible, shut
down the RAN before servicing the antenna.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 19
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Guard Against Damage from Electro‐Static Discharge
CAUTION!
Electro‐Static Discharge (ESD) can damage electronic components. To prevent ESD damage,
always wear an ESD wrist strap when working with the IRU or when handling any of its
components. Connect the ground wire on the ESD wrist strap to an earth ground source before
touching the IRU or any of its components. Wear the wrist strap the entire time that you work
with the IRU and its components.
CAUTION!
Place the PRism RF Modules in anti‐static packing material when transporting or storing them.
Unpack and Inspect the RF Module
Unpack and inspect the RF Module.
a Inspect the exterior of the shipping container(s) for evidence of rough handling that may
have damaged the components in the container.
b Unpack each container while carefully checking the contents for damage and verify with
the packing slip.
c If damage is found or parts are missing, file a claim with the commercial carrier and notify
TE Customer Service (see “Contacting TE Connectivity” on page 43). Save the damaged
cartons for inspection by the carrier.
d Save all shipping containers for use if the equipment requires shipment at a future date.
CAUTION!
Handle the RF Module with care during installation. Be especially careful to not damage the
thermal‐interface material (TIM), which is attached to the LPA. If the TIM is damaged, the LPA
can overheat. Before installing the RF Module, check to see if the heatsink material is gouged or
cracked. If the TIM is damaged, do not install the RF Module and contact TE Connectivity for
assistance (see “Contacting TE Connectivity” on page 43 for contact information).
CAUTION!
If the thermal‐interface material is damaged, the installation and use of the RF Module may void
the warranty of the RF Module.
Page 20
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Remove Release Liners from the RF Module
Remove Release Liners from the RF Module
NOTE:
Release Liners are present on front and back of new modules.
Open the PRU enclosure.
Remove release liners, if present, from the thermal pads on the RF Module prior to installing
the module into the PRU chassis.
CAUTION!
The thermal pads are very sensitive to mishandling—do not nick, scratch, or ding them.
For most RF Modules, the thermal pads are located as listed below and as shown in Figure 9,
which shows a Dual‐Slot 40W RF Module.
•
one large pad on the back surface of each Linear Power Amplifier (LPA)
•
up to two on the front surface (DARTs)
•
one on the left side for the (RDI)
•
one on the vector modulator board
•
one on the RF power combiner.
One thermal pad
for RF Power
Combiner
One thermal pad
for Vector
Modulator
One thermal pad
for each DART
One thermal pad
for each DART
One thermal pad
for the RDI
One large
thermal pad on each PA
(bottom of the LPA)
Figure 9. Thermal
Pads on a Dual-Slot 40W RF Module
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 21
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
For HDM RF Modules, the thermal pads are located as listed below and as shown in Figure 10.
•
one pad for each Rx and Tx board
•
one large pad over the DPM
•
one for each Power Amplifier (PA), which is on the bottom of the HDM RF Module.
DPM Thermal Pad
Rx B Thermal Pad
Rx A Thermal Pad
Tx A Thermal Pad
2.9796 in
Tx B Thermal Pad
NOTE: Tx and Rx cards are paired: Tx A ony pairs with Rx A and Tx B only pairs with Rx B.
Figure 10. Thermal
Page 22
© 2012 TE Connectivity Ltd
Pads on an HDM RF Module
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Dual-Slot Modules Only—Remove the Module Slot Shelf
Dual‐Slot Modules Only—Remove the Module Slot Shelf
For Dual‐Slot RF Modules only.
If you are installing a Dual‐Slot RF
Module, you must remove a module
slot shelf from the PRU chassis to
accommodate the module’s size.
(For further information, Table 6
on page 11.)
Remove the shelf as appropriate for
the RF Module:
•
For a Dual‐Slot 40W RF Module,
remove the Module B Shelf.
•
For a Dual‐Band Dual‐Slot RF
Module, remove Module D
Shelf.
To remove the module shelf:
a Use a 9/64” Allen™ wrench to
remove the three screws that
attach the module shelf to the
PRU chassis, as shown in the
following graphic.
b Discard or store the module
shelf and fasteners.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Remove Module D Shelf for
Dual-Band Dual-Slot RF Modules
Use 9/64” Allen Wrench to
remove the three module-shelf screws
Remove Module B Shelf for
Dual-Slot 40W RF Modules
Page 23
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Install the RF Module into the Prism Remote Chassis
Recommendation:
Install Dual‐Band Dual‐Slot modules in the two upper‐most slots of the PRU.
Recommendation:
Install Dual‐Slot 40W modules in the bottom‐most slots of the PRU.
Recommendation:
If both a Dual‐Slot AWS2100 40W RF Module and a Dual‐Slot PCS1900 40W
RF Module are installed in a Quad‐Band PRU, install the AWS2100 Module in
the lower‐most slot of the PRU.
Hold the RF Module so that the DART card(s) face away from the PRU and the Mounting Hook
is toward the Receiving flange on the PRU chassis.
NOTE:
Always install RF Modules from the bottom up. Do not skip a slot.
Holding the RF Module at a 45° angle in respect to the rear heatsink, rest the bottom surface
of the module on the RF Module shelf, as shown in one of the following graphics, and as
applicable to the RF Module.
•
Single‐Slot RF Module: Figure 11 on page 25
•
HDM RF Module: Figure 12 on page 26
•
Dual‐Band Dual‐Slot RF Module: Figure 13 on Page 27
•
Dual‐Slot 40W RF Module: Figure 14 on Page 28.
Page 24
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Install the RF Module into the Prism Remote Chassis
Heat Sink
RF MOD D
RF MOD C
Single-Slot
RF Module
RF MOD B
RF MOD A
SeRF
Module
Figure 11. Installing
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
a Single-Slot RF Module
Page 25
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
RF MOD D
RF MOD C
HDM RF Module
RF MOD B
RF MOD A
SeRF
Module
Figure 12. Installing
Page 26
© 2012 TE Connectivity Ltd
an HDM RF Module
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Install the RF Module into the Prism Remote Chassis
Installing a Dual-Band
Dual-Slot RF Module
Figure 13. Installing
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
a Dual-Band Dual-Slot RF Module
Page 27
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Figure 14. Installing
Page 28
© 2012 TE Connectivity Ltd
a Dual-Slot 40W RF Module
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Install the RF Module into the Prism Remote Chassis
Align the Mounting Hook on the module with the receiving flange on the PRU heat sink, and
then slide the RF Module in toward the flange until it can go no further.
RF Module
Mounting hook
Chassis
Receiving
flange
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 29
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Push the left edge of the RF Module back and into the PRU chassis until it can go no further, as
shown in the following graphics:
•
For Single‐Slot RF modules, see Figure 15 on page 30.
•
For HDM RF modules, see Figure 16 on page 31.
•
For Dual‐Slot RF modules, see Figure 17 on page 32, which uses the Dual‐Slot 40W RF
Module as an example.
CAUTION!
Make sure the RF Module is seated correctly in the Module shelf. Incorrect alignment of the RF
Module can cause the RF Module to fail due to over heating.
•
The front edge of the RF Module should be parallel with the shelf above it.
•
The Mounting Hook on the RF Module should be fully engaged with the Receiving flange on
the PRU chassis.
•
If you later cannot shut the PRU door, verify that the RF Module is installed correctly.
Single-Slot
RF Module
Push the RF Module
back into the chassis
until it can go no further.
Figure 15. Seating
Page 30
© 2012 TE Connectivity Ltd
a Single-Slot RF Module
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Install the RF Module into the Prism Remote Chassis
Push the HDM RF Module
back into the chassis
until it can go no further.
HDM
RF Module
Figure 16. Seating an HDM RF Module
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 31
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Push the RF Module back
into the chassis until it can
go no further.
Figure 17. Seating
a Dual-Slot RF Module
Secure RF Module Latches
To secure the module latches on the left side of the RF Module, do one of the following, as
appropriate for the RF Module being installed:
•
“Connect Latches on Single‐Slot and HDM RF Modules” on page 33
•
“Connect Latches on Dual‐Band Dual‐Slot RF Modules” on page 34.
Page 32
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Secure RF Module Latches
Connect Latches on Single‐Slot and HDM RF Modules
For Single‐Slot and HDM RF Modules, secure two latches, as shown in Figure 18.
Two latches on Single-Slot
RF Modules
Two latches on
HDM RF Modules
Figure 18. Latches
on Single-Slot and HDM RF Modules
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 33
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Connect Latches on Dual‐Band Dual‐Slot RF Modules
For Dual‐Band Dual‐Slot RF Modules, secure four latches, as shown in Figure 19.
Four latches in a
Dual-Band Dual-Slot
RF Module
Figure 19. Dual-Band
Page 34
© 2012 TE Connectivity Ltd
Dual-Slot RF Module Latches
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Secure RF Module Latches
Latches on Dual‐Slot 40W RF Modules
For Dual‐Slot 40W RF Modules, secure four latches, as shown in Figure 20.
Four latches
in a Dual-Slot
40W RF Module
Figure 20. Dual-Slot
40W RF Module Latches
Verify that the RF Module Mounting Hook is Engaged
10
Verify that the RF Module Mounting Hook is engaged correctly by pulling the module away
from the heat sink. The RF Module should not move. If the RF Module moves during this check,
repeat Step 6 on page 24 through Step 9.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 35
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Connect the RF Module Cables
11
Position the cables so that they are under the right edge of the RF Module, pointing up.
12
Follow the rules listed below when connecting the RF Module cables.
•
Always provided at each RF Module shelf are five cables:
– one Power (PWR) cable
– two RF cables (TX0/RX0) and (TX1/RX1)
– two high‐speed‐data cables, which in this document are referred to as Low‐Voltage
Differential Signaling (LVDS) cables.
•
LVDS cables labeled PRIM and DIV should always either be connected or strain relieved to
adjacent cables. This protects against the cable getting caught in the chassis door.
•
Make sure the two LVDS cables are fully seated and locked into their connectors.
•
If you are installing a module into a Diversity Chassis, both RF cables labeled MOD N
TX0/RX0 and MOD N TX1/RX1 will be populated.
•
For Diversity modules, all cables are to be connected.
•
When you order a Dual SuperDART module, connect both LVDS cables (PRIM and DIV) and
the RF TX0/RX0 cable.
•
Adhere to a minimum bend radius of 1‐inch for all RF cables from the integrated cable
guide to the module.
•
Maintain adequate strain relief distances from connection points to the module.
•
When installing Dual‐Slot RF modules:
– The upper RF Module shelf will either not be present (factory installed module) or will
be removed prior to installation (field installed module).
– For Dual‐Slot modules, only the RF cable labeled MOD N TX0/RX0 on the lower module
slot will be connected to the module connector TX0/RX0.
– The MOD N TX1/RX1 cable should be secured to the cable bundle using the provided
cable tie.
– Ensure that the MOD N TX1/RX1 cable and connector are secured so that they will not
be pinched or prevent the PRU door from closing.
– The Power (PWR) cable and two LVDS cables of the upper RF Module slot will not be
used. Connect the RF cable labeled MOD N TX1/RX1 to the connector labeled N/C on the
upper half of the double‐slot module. Use one of the provided cable ties to secure the
MOD N TX0/RX0 RF cable, both LVDS cables and the Power (PWR) cable to the RF cable
labeled MOD N TX1/RX1, ensuring that the cable bundle will not be pinched or prevent
the PRU door from closing.
Page 36
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Connect the RF Module Cables
13
Working from the bottom connector up, connect the RF Module cables.
a If this is a Diversity chassis:
• For Single‐Slot installations only—connect the RF Diversity cable labeled MOD N
TX1/RX1 to the TX1/RX1 connector and turn the thumbscrew to secure the cable to the
chassis.
• For Dual‐Slot installations only—the TX1/RX1 connector is pre‐populated. Do not
remove the factory connection to RX1. Instead, secure the MOD N TX1/RX1 cable to the
cable bundle using one of the provided cable ties. Ensure that the MOD N TX1/RX1 cable
and connector are secured so they will not be pinched or prevent the door from
closing.
b Connect the RF cable labeled MOD N TX0/RX0 to the TX0/RX0 connector and turn the
thumbscrew to secure the cable to the chassis.
c For Single‐Slot installations only—connect the MOD N DIV LVDS cable to the DIV
connector. This connects the Remote Unit SeRF (RSI) interface board to the Diversity
DART. Make sure that you hear the LVDS cable lock into the DIV connector with an audible
click. Give a gentle tug on the LVDS cable—if you do not press the unlock lever, the LVDS
cable should not come out of the connector.
NOTE:
Always connect the Diversity LVDS cable. This prevents the cable from getting caught between
the chassis door and the RF Module.
Connect the MOD N PRIM LVDS cable to the PRIM connector. This connects the RSI to the
Primary DART.
Connect the Power cable to the PWR connector. This connects the RF Module to the DC
power connection.
For Dual‐Slot installations only—the Power (PWR) cable and two LVDS cables of the
upper RF Module shelf are not be used. Connect the RF cable labeled MOD N TX1/RX1 of the
upper RF Module shelf to the connector labeled N/C on the upper half of the Dual‐Slot
module. Use one of the provided cable ties to secure the MOD N TX0/RX0 RF cable, both
LVDS cables and the Power (PWR) cable to the RF cable labeled MOD N TX1/RX1, ensuring
that the cable bundle will not be pinched or prevent the PRU door from closing.
Refer to the graphic that corresponds to the RF Module being installed:
•
Single‐Slot RF Module: Figure 21 on Page 38
•
HDM RF Module: Figure 22 on page 39
•
Dual‐Band Dual‐Slot RF Module: Figure 23 on Page 40
•
Dual‐Slot 40W RF Module: Figure 24 on Page 41.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 37
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Cable connections for a Single-Slot RF Module
MOD D
PWR
PRIM
DIV
MOD C
TX0/RX0
RX1
MOD B
MOD A
SeRF
Module
Note routing of
high-speed cables
Note bend
radii ≥ 1-inch
Edge of Connector Interface Panel
Figure 21. Cable
Page 38
© 2012 TE Connectivity Ltd
Connections for Single-Slot RF Modules
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Connect the RF Module Cables
Cable connections for an HDM RF Module
DATA 0 (PRIM)
DATA 1 (DIV)
POWER
TX1/RX1
TX0/RX0
Figure 22. Cable
Connections for HDM RF Modules
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 39
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Cable Connections for a Dual-Slot RF Module
Tie wrap
Two N-Type
RF connectors
Factory-installed
RX1 cable
Two N-Type
RF connectors
Figure 23. Cable Connections for Dual-Band
Page 40
© 2012 TE Connectivity Ltd
Dual-Slot RF Modules
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Connect the RF Module Cables
Keep cable bends
behind the edge
of the Connector
Interface Panel
Tie wrap around
factory-installed
RX1 cable
Figure 24. Cable
14
Connections for Dual-Slot 40W RF Modules
Ensure that all cable bends are below the top edge of the Connector Interface Panel as
indicated by the dashed line in the preceding figure. Failure to correctly position the cables
could inhibit closing the PRU door, which can result in damage to the cables.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 41
© 2012 TE Connectivity Ltd.
Install the RF Module(s)
Power on the RF Module
15
Follow the rules listed below to toggle the Power switch that corresponds to the RF Module
to its ON position.
•
For Dual‐Slot RF Modules, use the Power switch for the lower module.For example, to
power up a Dual‐Slot RF Module in combined slots C+D in a Quad‐Band chassis, turn ON
DC Power switch for Mod C; leave the DC Power switch for Mod D OFF.
•
A Dual‐Slot 40W RF Module uses the Power Supplies in both slots. If the Dual‐Slot 40W RF
Module is installed in slots C+D, turn ON the Power switch for Mod C and Mod D.
MOD D
MOD C
MOD B
MOD A
SeRF
Module
DC Power switch for Mod D
DC Power switch for Mod C
AC Power
switch for
Remote
chassis
16
DC Power switch for Mod B
DC Power switch for Mod A
Repeat Step 1 through Step 15 to install other RF Modules.
Page 42
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Contacting TE Connectivity by Telephone
CONTACTING TE CONNECTIVITY
Contacting TE Connectivity by Telephone
Sales
Asia Pacific
+65-6294-9948
France
0800 914032
Germany
0180 2232923
Italy
0800 782374
Spain
900 983291
United Kingdom
0800 960236
USA or Canada
1-800-366-3891
Extension
73000
Connectivity Extension
73475
Wireless Extension
73476
Technical Support
USA or Canada
1-800-530-9960
Elsewhere
+1-952-917-0761
Online Access to TE Connectivity
Customer Portal
https://www.te.com/commerce/uso/myaccount.do
Technical Support for Wireless Products
http://www.te.com/WirelessSupport
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012
Page 43
© 2012 TE Connectivity Ltd.
Contacting TE Connectivity
Page 44
© 2012 TE Connectivity Ltd
FlexWave Prism RF Modules for Prism Remote Units Installation Guide
TECP-77-141 • Issue 1 • April 2012


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : te106558
Create Date                     : 2012:11:13 09:48:53Z
Modify Date                     : 2012:11:13 10:15:21-08:00
Language                        : en
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 10.1.4 (Windows)
Creator Tool                    : FrameMaker 10.0.2
Metadata Date                   : 2012:11:13 10:15:21-08:00
Format                          : application/pdf
Title                           : FlexWave Prism RF Modules for Prism remote Units Installation Guide
Creator                         : te106558
Document ID                     : uuid:9f1b520a-ff9b-4789-a0f3-29c62cf4513e
Instance ID                     : uuid:8596f39e-fe6c-49ba-ab15-1e7b2b32ea2c
Page Mode                       : UseOutlines
Page Count                      : 48
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F8I-PSMAWS2D

Navigation menu