ADC Telecommunications S2191-011 The main function is to retransmits signals from and to the mobiles. User Manual InterReach Spectrum Remote Access Unit Installation Guide

ADC Telecommunications Inc. The main function is to retransmits signals from and to the mobiles. InterReach Spectrum Remote Access Unit Installation Guide

FCC RE0.6 MANUAL_Spectrum_RAU_Installation_Guide_FCC

Download: ADC Telecommunications S2191-011 The main function is to retransmits signals from and to the mobiles. User Manual InterReach Spectrum Remote Access Unit Installation Guide
Mirror Download [FCC.gov]ADC Telecommunications S2191-011 The main function is to retransmits signals from and to the mobiles. User Manual InterReach Spectrum Remote Access Unit Installation Guide
Document ID1881965
Application IDLHTS6sVZSrNxKRI0Yd62sg==
Document DescriptionFCC RE0.6 MANUAL_Spectrum_RAU_Installation_Guide_FCC
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize271.7kB (3396242 bits)
Date Submitted2013-01-18 00:00:00
Date Available2013-01-18 00:00:00
Creation Date2012-11-27 15:15:15
Producing SoftwareAcrobat Distiller 10.1.4 (Windows)
Document Lastmod2013-01-11 16:30:21
Document TitleInterReach Spectrum Remote Access Unit Installation Guide
Document CreatorFrameMaker 10.0.2
Document Author: te106558

™
InterReach Spectrum
Remote Access Unit
Installation Guide
TECP-77-222  Issue 1  November 2012
Main Remote Access Unit
Secondary Remote Access Unit
300001759666 Rev A
Copyright
© 2012 TE Connectivity, Inc. All Rights Reserved.
Information contained in this document is company private to TE Connectivity Ltd., and
shall not be modified, used, copied, reproduced or disclosed in whole or in part without
the written consent of TE.
Trademark Information
FlexWave, FlexWave Prism, InterReach Spectrum, Universal
Connectivity, and TE connectivity (logo) are trademarks.
Radio
Head,
TE
All other logos, products and/or company names referred to herein might be
trademarks of their respective owners.
Disclaimer of Liability
Contents herein are current as of the date of publication. TE reserves the right to change
the contents without prior notice. Should the content of printed user documentation
shipped with product differ from documentation provided on a product CD (inclusive of
the associated Help modules), the printed user documentation supersedes the
documentation on the product CD. In no event shall TE be liable for any damages
resulting from loss of data, loss of use, or loss of profits, and TE further disclaims any
and all liability for indirect, incidental, special, consequential or other similar damages.
This disclaimer of liability applies to all products, publications and services during and
after the warranty period.
Specific Disclaimer for High-Risk Activities
This Product is not specifically designed, manufactured, tested or intended for use in
high-risk activities including, without restricting the generality of the foregoing, on-line
control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the
design, construction, operation or maintenance of any nuclear facility. TE (including its
affiliates) and its suppliers specifically disclaim any express or implied warranty of
fitness for such purposes or any other purposes.
Screenshots in User Documentation
Due to concurrent development of this documentation, artwork, and the InterReach
Spectrum Element Management System (EMS), there may be some minor discrepancies
between screenshots contained in this documentation and those actually displayed in
the InterReach Spectrum EMS. These discrepancies will generally be few and minor and
should not affect your understanding of InterReach Spectrum EMS.
TABLE OF CONTENTS
Topics
Page
Preface .................................................................................................................................................................2
InterReach Spectrum User Documentation ........................................................................................................... 2
Accessing User Documentation on the TE Customer Portal...............................................................................................3
Document Cautions and Notes...........................................................................................................................................3
Standards Certification........................................................................................................................................... 4
Product Overview.................................................................................................................................................5
Main Remote Access Units..................................................................................................................................... 7
MRAU Ports, Cable, and Connectors ..................................................................................................................................7
MRAU LEDs .........................................................................................................................................................................8
Secondary Remote Access Units ............................................................................................................................ 9
SRAU Ports, Cable, and Connectors....................................................................................................................................9
SRAU LEDs.........................................................................................................................................................................10
RAU N Connectors................................................................................................................................................ 11
Install the RAUs and Antennas............................................................................................................................12
Mount the RAUs and Antennas............................................................................................................................ 12
General Safety Precautions .................................................................................................................................. 12
Connect the IFEU to the MRAU............................................................................................................................ 14
Connect the MRAU to SRAUs ............................................................................................................................... 16
Configure the MRAUs and SRAUs......................................................................................................................... 18
Appendix A: Specifications..................................................................................................................................19
Remote Access Unit Specifications ...................................................................................................................... 19
Spectrum System Specifications........................................................................................................................... 19
Composite Power Out of RAU .............................................................................................................................. 21
Appendix B: 75‐Ohm CATV Cable ........................................................................................................................24
CATV Cable Requirements.................................................................................................................................... 24
Belden 1695A Coax Specifications ....................................................................................................................... 25
Description .......................................................................................................................................................................25
Overall Physical Characteristics ........................................................................................................................................25
Overall Nominal Electrical Characteristics........................................................................................................................26
Belden 7732A Coax Specifications ....................................................................................................................... 27
Description .......................................................................................................................................................................27
Overall Physical Characteristics ........................................................................................................................................27
Overall Nominal Electrical Characteristics........................................................................................................................28
Appendix C: Omni Antenna.................................................................................................................................29
Appendix D: Contacting TE Connectivity .............................................................................................................30
Contacting TE Connectivity by Telephone............................................................................................................ 30
Online Access to TE Connectivity ......................................................................................................................... 30
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 1
©2012 TE Connectivity Ltd.
Preface
PREFACE
This manual provides installation instructions for InterReach Spectrum® Remote Access Units
(RAUs). Table 1 lists the standard RAUs that are supported in this document.
Table 1.
Catalog Number
Supported Spectrum Standard Remote Access Units
Description
Standard RAUs
SPT-M1-8519-1
Spectrum, 850-1900 Main RAU
SPT-S1-8519-22
Spectrum, 850 Path 2-1900 Path 2 Secondary RAU
SPT-S1-8090-1
Spectrum, 800-900 SMR Secondary RAU
SPT-S1-80AWS-1
Spectrum, 800-2100AWS Path 1 Secondary RAU
SPT-S1-8019-22
Spectrum, 800 Path 2-1900 Path 2 Secondary RAU
SPT-S2-70AWS-1-SISO
Spectrum, 700 SISO-2100AWS Path 1 SEC RAU, UpperC-LowerABC
SPT-S2-70AWS-22-SISO Spectrum, 700 Path 2 SISO-2100AWS Path 2 SEC RAU, UpperC-LowerABC
SPT-S1-7070-1-MIMO
Spectrum, 700 MIMO Secondary RAU, UpperC-LowerABC
SPT-M1-AWS19-11
Spectrum, 2100AWS Path 1-1900 Path 1 Main RAU
SPT-S1-AWS19-12
Spectrum, 2100AWS Path 1-1900 Path 2 Secondary RAU
SPT-S1-2121-1-MIMO
Spectrum, 2100AWS MIMO Secondary RAU
High Power RAUs
SPT-M3-8519-11-HP
Spectrum, 850 Path1-1900 HP Main RAU
SPT-S3-8519-22-HP
Spectrum, 850 Path2 - 1900 HP Path2 Secondary RAU
SPT-S3-70AWS-11-HP
Spectrum, 700 Path1 uC/LABC-AWS HP Path1 Secondary RAU
SPT-S3-70AWS-22-HP
Spectrum, 700 Path2 uC/LABC-AWS HP Path2 Secondary RAU
InterReach Spectrum User Documentation
The InterReach Spectrum user documentation is intended for system administrators, engineers
and installers responsible for planning, administering, configuring, and maintaining TE
Connectivity InterReach Spectrum systems. Table 1 lists the manuals that correspond to this
InterReach Spectrum release.
Table 2.
InterReach Spectrum User Documentation
Title
TECP Number
InterReach Spectrum Element Management System 8.1 User Manual
InterReach Spectrum Host Unit Installation Guide
InterReach Spectrum Expansion Module Group Installation Guide
InterReach Spectrum Remote Access Unit Installation Guide
FlexWave Prism OADM Splice Box Installation Guide
TECP-77-215
Page 2
© 2012 TE Connectivity Ltd
TECP-77-220
TECP-77-221
TECP-77-222
TECP-77-208
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
InterReach Spectrum User Documentation
Accessing User Documentation on the TE Customer Portal
Access to the Customer Portal requires a user account and password. If you do not have an
account, click on the registration link on the Log In page.
Click on the following URL link or enter the URL into your web browser, and then press Enter
on your keyboard:
https://www.te.com/commerce/uso/myaccount.do
Click My Account > TE/Wireless Portal.
On the Customer Portal Home page, click Manuals and Data Sheets.
In the Manuals and Data Sheets Sections panel, click on the product name of the document you need
to access.
Click on the title of the manual that you need to open/download.
Document Cautions and Notes
Two types of messages, identified below, appear in the text:
CAUTION!
Caution text indicates operations or steps that could cause personal injury, induce a safety
problem in a managed device, destroy or corrupt information, or interrupt or stop services.
NOTE:
Note text contains information about special circumstances.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 3
© 2012 TE Connectivity Ltd.
FCC: This equipment complies with the applicable sections of Title 47 CFR, Part 22
(800 MHz Cellular), Part 24 (1900 MHz ‐ PCS), Part 90 (800/900 ‐ SMR), and Part 27
(700 MHz, 2100 MHz‐ AWS).
This device complies with part 15 of the FCC Rules. Operation is subject to the condition
that this device does not cause harmful interference.
NOTE: The U.S. Federal Communications Commission (FCC) has developed guidelines
for evaluation of human exposure to RF emissions. The guidelines incorporate limits
for Maximum Permissible Exposure (MPE) for power density of transmitter operating at
frequencies between 300 kHz and 100 GHz. Limits have been set for portable, mobile,
and fixed equipment. TE Connectivity products fall in the category of fixed equipment;
products intended to be permanently secured and exposures are evaluated for
distances greater than 40cm (15.75”). Portable devices fall into exposures of less than
20cm, where SAR evaluations are used.
Antenna gain is restricted to 390mW ERP .( 8 30mW EIRP) in order to satisfy RF exposure
compliance requirements. If higher than 38 5mW ERP, routine MPE evaluation is needed.
The antennas should be installed to provide at least 40cm from all persons to satisfy
MPE requirements of FCC Part 2, 2.1091.
UL/CUL: This will be installed in a restricted access location. This equipment complies,
per UL and CUL 50, Standard for Enclosures for Electrical Equipment.
UL/CUL: This equipment complies with UL and CUL 60950‐1 Standard for Safety for
Information Technology Equipment, including Electrical Business Equipment.
UL/CUL: All InterReach Spectrum RAUs are Plenum rated and suitable for use in
environmental air space in accordance with Section 300‐22(C) of the National Electrical
Code, and Sections 2‐128, 12‐010(3) and 12‐100 of the Canadian Electrical Code, Part 1,
CSA C22.1.
UL: This equipment is UL Plenum rated under UL 2043.
CAUTION! Modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Standards Certification
PRODUCT OVERVIEW
InterReach Spectrum supports up to 8 bands in a single system. Each antenna location supports
those bands in modular, group pairings. Each location includes a Main Remote Access Unit
(MRAU) that can power up to three additional Secondary RAUs (SRAUs), each of which support
two power amplifier pairs for a total of eight amplifiers. MRAUs and SRAUs are grouped logically
based on common service provider groupings and include: 850/1900, 700/700 MIMO, 800/900
SMR, 700 SISO/AWS, and 800/AWS. Adding frequency is as simple as plugging in an SRAU to the
existing MRAU.
RAUs are available in two different output power options: Standard and High Power. These can
be “mixed and matched” on a system to meet the specific needs of a venue.
Since Spectrum can be configured to support as many as four cascaded runs of sixteen total
Expansion Module Groups, the system configuration possibilities are seemingly endless and can
scale to single systems that include as many as 128 MRAU locations, with each of those locations
supporting between one and eight RF bands. And each of those band locations offers 26 dBm
(P1dB) or 31 dBm (P1dB) of output power based on selecting standard or High Power (HP) RAUs.
The system may be scaled to add new bands or RAU location sites as‐needed and offers great
service flexibility and performance relative to shared, wide‐band amplifier systems. Each service
provider may control their band of interest and enjoy the predictability in consistent service at
each RAU location independent of what other operators are doing or the length the signal travels
to the service area.
The RAUs are typically mounted above ceiling tiles or in out‐of‐sight locations as close as possible
to the service area.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 5
© 2012 TE Connectivity Ltd.
Product Overview
Figure 1 illustrates how RF and IF signals are sent between Spectrum units and modules.
NOTE:
All FWD ports on all Modules are color‐coded red and all REV ports are color‐coded blue, which
makes the DRU, IFEU, and RAU cabling process easier to complete.
RF DART
HOST
SMR900
FWD 935-940
REV 896-901
REV
RF OUT
PWR
STATUS
RF DART
Host
PWR
STATUS
HOST
REV
RF OUT
HOST
SMR900
FWD 935-940
REV 896-901
REV
RF OUT
RF DART
SMR900
FWD 935-940
REV 896-901
FWD
RF IN
FWD NOT TO
EXCEED +5 dBm
PWR
STATUS
FWD
RF IN
FWD NOT TO
EXCEED +5 dBm
RF DART
HOST
SMR900
FWD 935-940
REV 896-901
REV
RF OUT
FWD
RF IN
PWR
STATUS
FWD NOT TO
EXCEED +5 dBm
FWD
RF IN
FWD NOT TO
EXCEED +5 dBm
HOST
SYSTEM II
RF
IF DART
REMOTE
XXXXXXXXXX
BW XX MHz
PWR
REMOTE
REV
IF IN
STATUS
IF DART
FWD
IF OUT
REMOTE
XXXXXXXXXX
BW XX MHz
FWD
IF OUT
DRU
IF
DART
XXXXXXXXXX
BW XX MHz
FWD
IF OUT
PWR
REV
IF IN
STATUS
IF DART
REMOTE
XXXXXXXXXX
BW XX MHz
FWD
IF OUT
REV
IF IN
STATUS
PWR
PWR
REV
IF IN
STATUS
REMOTE
SYSTEM II
IF
IFEU
Power
Supply
MRAU
REV IF OUT
REV SECONDARY PORTS
LINK
STATUS
FWD SECONDARY PORTS
IF
RF
FWD IF IN
IF
RF
SRAU
SECONDARY
SECONDARY
REV
FWD
LINK
SECONDARY
REV
Omni
Antenna
STATUS
LINK STATUS
SECONDARY
FWD
NOTE: Units shown are not to scale.
Figure 1. REV and FWD Signals for the RAU
NOTE:
This book refers to the Omni Antenna (4214‐M727), which is the antenna that TE Connectivity
recommends. Other antennas may be used. For further information on the Omni Antenna, see
“Appendix C: Omni Antenna” on page 29.
Page 6
© 2012 TE Connectivity Ltd
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Main Remote Access Units
Main Remote Access Units
The Main Remote Access Unit (MRAU) receives FWD IF signals from an IF Expansion Unit (IFEU),
which is part of the Spectrum Expansion Module Group, using 75 CATV cable. The MRAU
converts the IF signals to RF and sends them to a passive RF antenna using 50 coaxial cable. The
MRAU also receives configuration information and power from and sends its status information
to the IFEU.
The MRAU receives REV RF signals from a passive RF antenna using 50 coaxial cable. It converts
the signals to IF and sends them to the IFEU using 75 CATV cable.
MRAU Ports, Cable, and Connectors
REV IF OUT
REV SECONDARY PORTS
Ref # Component
RF SubMiniature version A
(SMA) cable (1)
LINK
STATUS
FWD SECONDARY PORTS
Device
FWD IF IN
Function
50 RF SMA-to-SMA cable Connects two RF bands together when there is only one
N-type connector on the RAU.
For cases when there is an N-type connector for each RF
band (700MIMO or PCS/AWS), there will not be an SMA
cable.
Antenna port(s)
50 N-type connector
Connects to an antenna. See Table 3 on page 11.
FWD IF IN connector
F connector port
Connects to the IFEU FWD Module IF OUT connector via
CATV cable.
FWD SECONDARY PORTS (1 - 3) F connector ports
Connect to a SRAU SECONDARY FWD connector via
CATV cable.
REV SECONDARY PORTS (1 - 3) F connector ports
Connect to a SRAU SECONDARY REV connector via
CATV cable.
REV IF OUT connector
Connects to the IFEU REV Module IF IN connector via
CATV cable.
F connector port
(1) The AWS/PCS MRAUs does NOT have an RF SMA cable, and has two Antenna ports.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 7
© 2012 TE Connectivity Ltd.
Product Overview
MRAU LEDs
REV IF OUT
REV SECONDARY PORTS
Ref # LED
FWD SECONDARY PORT 
(1 - 3)
REV SECONDARY PORT
(1 - 3)
FWD IF IN
FWD SECONDARY PORTS
FWD IF IN
Description
• Green
• Downstream unit correctly connected; unit has no alarms or a
Minor alarm is active.
• Blinking Green
• SRAU or band is set out-of-service.
• Yellow
• FWD cable connected to SRAU, no REV cable connected.
• Blinking Yellow • FWD and REV cables are not connected to the same port number
(incorrectly paired).
• Red
• Major alarm in downstream unit, fault lockout, or SRAU
disconnected.
• Off
• No SRAU previously connected.
• Green
• MRAU receiving communications from the IFEU.
• Red
• MRAU has not received communications from the IFEU for more
than 90 seconds.
• Off
• During initial power up, MRAU is powering up and waiting for IFEU
communications.
• Green
• Unit has no alarms or a Minor alarm is active.
• Blinking Green
• Unit or band is set out-of-service.
• Red
• Major alarm detected.
• Green
• Downstream unit correctly connected, unit has no alarms or minor
alarm
• Blinking Green
• SRAU or band is set out-of-service.
• Blinking Yellow • FWD and REV cables are not connected to the same port number
(incorrectly paired).
• Red
• Major alarm in downstream unit, fault lockout, or SRAU
disconnected.
• Off
• No SRAU previously connected.
• Green
• MRAU is powered on correctly.
• There is an IFEU FWD connection, but there is no IFEU REV
• Yellow or
Blinking Yellow
connection or the IFEU REV connection is paired incorrectly.
• Off
Page 8
© 2012 TE Connectivity Ltd
STATUS
LED Color
LINK
STATUS
LINK
• Cable is not connected to the IFEU FWD port.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Secondary Remote Access Units
Secondary Remote Access Units
A Secondary Remote Access Unit (SRAU) receives FWD IF signals from the MRAU, using 75
CATV cable. The SRAU converts the IF signals to RF and sends them to a passive RF antenna using
50 coaxial cable. The SRAU, through the MRAU, also receives configuration information and
power from and sends its status information to the IFEU.
The SRAU receives REV RF signals from a passive RF antenna using 50 coaxial cable. It converts
the signals to IF and sends them to the MRAU using 75 CATV cable.
SRAU Ports, Cable, and Connectors
SECONDARY
SECONDARY
REV
FWD
LINK
SECONDARY
REV
Ref
Component
SECONDARY REV connector
RF SMA cable (1)
STATUS
SECONDARY
FWD
LINK STATUS
Device
Function
F connector port
Connects to one of the MRAU REV SECONDARY ports (1 - 3)
via CATV cable.
50 RF SMA-to-SMA cable
Antenna port(s)
50 N-type connector
SECONDARY FWD connector F connector port
Connects two RF bands together when there is only one
N-type connector on the RAU.
For cases when there is an N-type connector for each RF band
(700MIMO or PCS/AWS), there will not be an SMA cable.
Connects to an antenna. See Table 3 on page 11.
Connects to one of the MRAU FWD SECONDARY ports (1 - 3)
via CATV cable.
(1) The 700 MIMO SRAUs does NOT have an RF SMA cable, and has two Antenna ports.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 9
© 2012 TE Connectivity Ltd.
Product Overview
SRAU LEDs
SECONDARY
SECONDARY
REV
FWD
LINK
SECONDARY
REV
LED Color
Description
• Green
• SRAU receiving communications from the IFEU.
• Red
• SRAU has not received communications from the IFEU for more than 90
seconds.
• Off
• During initial power up, SRAU is powering up and waiting for IFEU
communications.
• Green
• Unit has no alarms or a Minor alarm is active.
• Blinking Green
• Unit or band is set out-of-service.
• Red
• Major alarm detected.
• Green
• SRAU is powered on correctly.
LINK
STATUS
SECONDARY
FWD
LINK STATUS
Ref # LED
STATUS
• There is an MRAU FWD connection, but there is no MRAU REV connection
SECONDARY FWD • Yellow or
Blinking Yellow
or the MRAU REV connection is paired incorrectly.
• Off
Page 10
© 2012 TE Connectivity Ltd
• Cable is not connected to the MRAU FWD port.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
RAU N Connectors
RAU N Connectors
Each RAU also has one or two 50‐ N‐type connectors that connect to a passive antenna. Table 3
lists the number of N‐type connectors available on each RAU model.
Table 3.
Catalog Number
Number of N Connectors on RAUs
Description
Number of RF
N Connectors*
Standard RAUs
SPT-M1-8519-1
Spectrum, 850-1900 Main RAU
SPT-M1-AWS19-11
Spectrum, 2100AWS Path 1-1900 Path 1 Main RAU
SPT-S1-2121-1-MIMO
Spectrum, 2100AWS MIMO Secondary RAU
SPT-S1-7070-1-MIMO
Spectrum, 700 MIMO Secondary RAU, UpperC-LowerABC
SPT-S1-8019-22
Spectrum, 800 Path 2-1900 Path 2 Secondary RAU
SPT-S1-8090-1
Spectrum, 800-900 SMR Secondary RAU
SPT-S1-80AWS-1
Spectrum, 800-2100AWS Path 1 Secondary RAU
SPT-S1-8519-22
Spectrum, 850 Path 2-1900 Path 2 Secondary RAU
SPT-S1-AWS19-12
Spectrum, 2100AWS Path 1-1900 Path 2 Secondary RAU
SPT-S2-70AWS-1-SISO
Spectrum, 700 SISO-2100AWS Path 1 SEC RAU, UpperC-LowerABC
SPT-S2-70AWS-22-SISO Spectrum, 700 Path 2 SISO-2100AWS Path 2 SEC RAU, UpperC-LowerABC
High Power RAUs
SPT-M3-8519-11-HP
Spectrum, 850 Path1-1900 HP Main RAU
SPT-8519-22-HP
Spectrum, 850 Path2 - 1900 HP Path2 Secondary RAU
SPT-S3-70AWS-11-HP
Spectrum, 700 Path1 uC/LABC-AWS HP Path1 Secondary RAU
SPT-S3-70AWS-22-HP
Spectrum, 700 Path2 uC/LABC-AWS HP Path2 Secondary RAU
There are two bands per RAU, which results in two N connectors. When there is one N connector, the two bands are
combined internally and both bands use the single N connector.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 11
© 2012 TE Connectivity Ltd.
Install the RAUs and Antennas
INSTALL THE RAUS AND ANTENNAS
Follow the steps in the order provided to install the RAUs and antennas.
Mount the RAUs and Antennas
General Safety Precautions
CAUTION!
Wet conditions increase the potential for receiving an electrical shock when installing or using
electrically powered equipment. To prevent electrical shock, never install or use electrical
equipment in a wet location or during a lightning storm.
CAUTION!
This system is a RF Transmitter and continuously emits RF energy. Maintain a minimum 8‐inch
(20 cm) clearance from the antenna while the system is operating. Whenever possible, shut
down the RAN before servicing the antenna.
NOTE:
RAUs are suitable for use in environmental air space in accordance with Section 300‐22(c) of the
National Electrical Code, and Sections 2‐128, 12‐010(3) and 12‐100 of the Canadian Electrical
Code, Part 1, CSA C22.1.
CAUTION!
Install RAUs in indoor locations only. Do not connect an antenna installed in an outdoor location
to a RAU, unless it is in an approved AOC weatherproof NEMA4 housing.
CAUTION!
Attach all RAUs securely to a stationary object (that is, a wall, pole, or ceiling brackets). To mount
a RAU securely to a wall, ceiling bracket, or pole, use #6 diameter fasteners in the four slotted
mounting holes.
CAUTION!
Do the following to maintain proper ventilation:
•
•
•
Keep at least 76 mm (3‐inch) clearance around the RAU.
Do not stack RAUs on top of each other.
Always mount the RAU with the solid face (containing the mounting holes) against the
mounting surface.
NOTE:
You can place the RAU, without its fastening hardware, on a flat surface, such as a shelf, desk,
cabinet, or any other horizontal surface that allows stable placement, with the mounting base
facing down to the mounting surface.
CAUTION!
If installing the RAU on a flat surface, the surface must be able to hold a minimum 7‐pound load
securely.
Page 12
© 2012 TE Connectivity Ltd
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
General Safety Precautions
Do the following, in the order presented, to mount the RAUs and antennas:
Mount all MRAU and SRAUs in the locations marked on the floor plans.
Install the passive antennas according to the manufacturer’s installation instructions.
NOTE:
It is common practice to install passive antennas below the ceiling. If you install a passive
antenna above the ceiling, when estimating the antenna coverage area, account for additional
loss due to the ceiling material.
Connect a passive multi‐band antenna to the N connector on each RAU using coaxial cable
with the least amount of loss possible. (See “Appendix C: Omni Antenna” on page 29 for
information on the Omni Antenna ports.)
CAUTION!
Firmly hand‐tighten the N connector. DO NOT over‐tighten the connector.
MRAU
REV IF OUT
SRAU
N1
REV SECONDARY PORTS
FWD SECONDARY PORTS
LINK
FWD IF IN
N1
SECONDARY
SECONDARY
FWD
REV
LINK
STATUS
STATUS
False Ceiling
Coaxial cable
Coaxial cable
Omni Antenna
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 13
© 2012 TE Connectivity Ltd.
Install the RAUs and Antennas
Connect the IFEU to the MRAU
NOTE:
The IFEU should be powered up before starting this procedure; see the InterReach Spectrum
Expansion Module Group Installation Guide (TECP‐77‐167).
Follow these rules for the CATV cables when connecting the IFEU to the MRAU:
•
The FWD and REV cables should be close to the same length.
•
The FWD and REV cables should be the same cable type (both RG6 or both RG11).
•
A pair of CATV cables connects each MRAU to the IFEU. The IFEU REV Module IF IN port
and the IFEU FWD Module IF OUT port must match. For example, if IFEU REV Module IF
IN Port 3 is used, use IFEU FWD Module IF OUT Port 3.
•
Refer to “Appendix B: 75‐Ohm CATV Cable” on page 24 for information on maximum RG‐6
or RG‐11 CATV cable lengths.
Test the cable termination for each CATV cable before installing it.
Connect F connector CATV cables on the IFEU and MRAU, in the order given below.
If the LEDs do not perform as described in this procedure, refer to “MRAU LEDs” on page 8.
Connect a CATV cable from one of the IFEU FWD Module IF OUT connectors (1 ‐ 8) to the
MRAU FWD IF IN connector.
Confirm that the MRAU FWD IF IN LED is yellow, which indicates a correct physical
connection.
Connect a CATV cable from the IFEU REV Module IF IN connector (1 ‐ 8) to the MRAU REV
IF OUT connector, making sure that you pair the port used to the same port number
selected in Step 6a.
If the connection is correct, the MRAU powers up and the MRAU FWD IF IN LED turns
green.
Page 14
© 2012 TE Connectivity Ltd
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Connect the IFEU to the MRAU
IFEU
Step 6a
Step 6c
To an antenna
MRAU
REV IF OUT
REV SECONDARY PORTS
LINK
STATUS
FWD SECONDARY PORTS
FWD IF IN
Step 6b
KEY:
IFEU FWD Module IF OUT connector to MRAU FWD IF IN connector
IFEU REV Module IF IN connector to MRAU REV IF OUT connector
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 15
© 2012 TE Connectivity Ltd.
Install the RAUs and Antennas
Connect the MRAU to SRAUs
CAUTION!
To prevent interference, do not install an 850/1900 MRAU antenna near an 800/900 SRAU. The
850 MHz band must be 20 feet away from the 800/1900 SRAU’s passive antenna.
Use one of the following 6’ and 20’ CATV RG6 jumpers, available for purchase from TE
Connectivity, to connect an MRAU to SRAUs.
TE Connectivity
Part Number
Description
Note
300469-0
6’ RG-6 Cable; F Male to F Male
CATV cable that connects the MRAU to SRAUs. Two
cables required per SRAU.
300469-1
20’ RG-6 Cable; F Male to F Male CATV cable that connects the MRAU to SRAUs. Two
cables required per SRAU.
Test the cable termination for each CATV cable before installing it.
Connect F connector CATV cables from the MRAU to an SRAU, in the order given below. If the
LEDs do not perform as described in this procedure, refer to “SRAU LEDs” on page 10.
Connect a CATV cable from an MRAU FWD SECONDARY PORT (1, 2, or 3) F connector to
the SRAU SECONDARY FWD F connector.
Confirm that the SRAU SECONDARY FWD LED is yellow, which indicates a correct
physical connection.
Connect a CATV cable from an MRAU REV SECONDARY PORT (1, 2, or 3) F connector to
the SRAU SECONDARY REV F connector, matching the same port number selected in Step
9a. That is, if in Step 9a you connected an F connector to the MRAU FWD SECONDARY
PORT 1, the paired CATV cable must connect to the MRAU REV SECONDARY PORT 1.
If the connection is correct, the SRAU powers up and the SRAU SECONDARY FWD LED
turns green.
Page 16
© 2012 TE Connectivity Ltd
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Connect the MRAU to SRAUs
To an antenna
MRAU
To an IFEU
REV Module
IF IN connector
(1 - 8)
REV IF OUT
REV SECONDARY PORTS
Step 9c
LINK
STATUS
FWD SECONDARY PORTS
FWD IF IN
To an IFEU
FWD Module
IF OUT connector
(1 - 8)
Step 9a
To an antenna
SRAU
SECONDARY
SECONDARY
REV
FWD
LINK
SECONDARY
REV
KEY:
STATUS
LINK STATUS
MRAU FWD Secondary port to SRAU Secondary FWD port
SECONDARY
FWD
Step 9b
MRAU REV Secondary port to SRAU Secondary REV port
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 17
© 2012 TE Connectivity Ltd.
Install the RAUs and Antennas
10
Repeat Step 9 to install up to two more SRAUs, as per system design.
MRAU
To an antenna
REV IF OUT
REV SECONDARY PORTS
LINK
STATUS
FWD SECONDARY PORTS
FWD IF IN
To an IFEU REV Module
IF IN connector (1 - 8)
To an IFEU FWD Module
IF OUT connector (1 - 8)
To an antenna
SECONDARY
SECONDARY
REV
SRAU1
KEY:
SECONDARY
FWD
LINK
FWD
SECONDARY
REV
FWD
STATUS
LINK
To an antenna
To an antenna
SECONDARY
STATUS
SRAU3
SECONDARY
REV
FWD
LINK
STATUS
REV
SRAU2
Configure the MRAUs and SRAUs
Refer to the InterReach Spectrum™ Element Management System 7.3 User Manual (TECP‐77‐200)
for information on how to configure the MRAUs and SRAUs.
Page 18
© 2012 TE Connectivity Ltd
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Remote Access Unit Specifications
APPENDIX A: SPECIFICATIONS
Remote Access Unit Specifications
Operating Temp
‐25°C to +50°C
Storage Temperature
‐40°C to +70°C
Humidity
10% to 95% non‐condensing
Dimensions
11.50" x 9.00" x 3.50"
Weight
7.49 Pounds
Power Source
+54Vdc (from IFEU)
Spectrum System Specifications
RF Specification
Supported Frequency Blocks
2 per Remote Antenna Unit; 1‐8 per Host Unit
Bandwidth
1.5 to 75 MHz non‐contiguous
Frequency Band Supported
850 Cellular; 800 iDEN; 900 iDEN; 1900 PCS; 2100 AWS;
700 Upper C Lower ABC
Low/Medium
Power Level
700‐900 MHz
Typical
TX
Low/Medium
Power Level
1900‐2100 MHz
Typical
RX
TX
40 /43
30
Ripple with 180 m CATV (dB)
2.5
3.0
Output IP3 (dBm)
38
Average gain with 180 m CATV 
at 25°C (77° F) (dB)
Input IP3 (dBm)
RX
TX
RX
40 /43
30
48
30
3.5
4.0
3.5
4.0
38
‐8
Output 1 dB Compression Point (dBm)
26
High
Power Level
1900‐2100 MHz
Typical
43
‐8
26
‐8
31
Noise Figure 1 HU‐1 EMG‐8 RAUs (dB)
17
17
17
Noise Figure 1 HU‐4 EMG‐32 RAUs (dB)
23
23
23
Low Power is defined here as a Standard MRAU used
with Standard SRAUs.
Medium Power is defined here as a High Power MRAU
used with Standard SRAUs.
Propagation Delay
System Delay
<12 microseconds
Delay Management Digital
(Manual or Automatic)
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 19
© 2012 TE Connectivity Ltd.
Appendix A: Specifications
Nominal Passband Gains
RF Frequency
TX
RX
Bandwidth
869-894
824-849
Gain (dB)
40
30
850 Cell
800 SMR
Bandwidth
851-869
806-824
Gain (dB)
40
30
Bandwidth
935-940
896-901
Gain (dB)
40
30
Bandwidth
1930-1995
1850-1915
Gain (dB)
40
30
Bandwidth
2110-2155
1710-1755
Gain (dB)
40
30
Bandwidth
746-756
776-786
Gain (dB)
40
30
900 SMR
1900 PCS
2100 AWS
700 Upper C
700 Lower ABC
Page 20
© 2012 TE Connectivity Ltd
Bandwidth
728-746
Gain (dB)
40
698-716
30
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Composite Power Out of RAU
Composite Power Out of RAU
Table 4.
Low Power Level: Standard MRAU with SRAUs
Power per Carrier (dBm) per
Band
RF Frequency
TX
RX
Number of RF Carriers
P-out
P-out
P-Out P-out
26.0
20.0
14.0
9.0
GSM
23.0
17.5
12.0
8.0
EDGE
15.0
12.0
9.0
6.0
CDMA
15.0
12.0
9.0
6.0
WCDMA
Standard SRAUs
15.0
12.0
9.0
6.0
LTE
•
•
•
•
•
•
•
•
•
SPT-S1-8090-1
17.5
14.0
10.0
6.5
iDEN
SPT-S1-7070-1-MIMO
26.0
19.5
13.5
8.5
APCO 25 C4FM
15.0
12.0
9.0
6.0
CDMA
15.0
12.0
9.0
6.0
LTE
17.5
14.0
10.0
6.5
iDEN
26.0
20.0
13.5
9.0
APCO 25 C4FM
26.0
20.0
14.0
9.0
GSM
23.0
17.5
12.0
8.0
EDGE
15.0
12.0
9.0
6.0
CDMA
15.0
12.0
9.0
6.0
WCDMA
15.0
12.0
9.0
6.0
LTE
15.0
12.0
9.0
6.0
WCDMA
15.0
12.0
9.0
6.0
LTE
15.0
12.0
9.0
6.0
LTE
Standard MRAUs:
• SPT-M1-8519-1
• SPT-M1-AWS19-11
SPT-S1-80AWS-1
850 Cell
800 SMR
869-894
851-869
824-849
806-824
SPT-S2-70AWS-1-SISO
SPT-S2-70AWS-22-SISO
SPT-S1-AWS19-12
900 SMR
935-940
896-901
SPT-S1-2121-1-MIMO
SPT-S1-8019-22
SPT-S1-8519-22
1900 PCS
1930-1995
1850-1915
2100 AWS
2110-2155
1710-1755
700 Upper C
746-756
776-786
700 Lower ABC 728-746
698-716
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 21
© 2012 TE Connectivity Ltd.
Appendix A: Specifications
Table 5.
Medium Power Level: High Power MRAUs1 used with Standard SRAUs
Power per Carrier (dBm) per
Band
RF Frequency
TX
850 Cell
869-894
RX
824-849
Number of RF Carriers
P-out
P-out
P-Out P-out
26.0
20.0
14.0
9.0
GSM
23.0
17.5
12.0
8.0
EDGE
18.0
15.0
12.0
9.0
CDMA
18.0
15.0
12.0
9.0
WCDMA
Standard SRAUs
18.0
15.0
12.0
9.0
LTE
•
•
•
•
•
•
•
•
•
17.5
14.0
10.0
6.5
iDEN
26.0
19.5
13.5
8.5
APCO 25 C4FM
18.0
15.0
12.0
9.0
CDMA
SPT-S2-70AWS-1-SISO
18.0
15.0
12.0
9.0
LTE
SPT-S2-70AWS-22-SISO
17.5
14.0
10.0
6.5
iDEN
26.0
19.5
13.5
8.5
APCO 25 C4FM
26.0
20.0
14.0
9.0
GSM
23.0
17.5
12.0
8.0
EDGE
18.0
15.0
12.0
9.0
CDMA
18.0
15.0
12.0
9.0
WCDMA
18.0
15.0
12.0
9.0
LTE
18.0
15.0
12.0
9.0
WCDMA
18.0
15.0
12.0
9.0
LTE
18.0
15.0
12.0
9.0
LTE
SPT-S1-8090-1
SPT-S1-7070-1-MIMO
SPT-S1-80AWS-1
SPT-S1-AWS19-12
800 SMR
900 SMR
851-869
935-940
806-824
896-901
SPT-S1-2121-1-MIMO
SPT-S1-8019-22
SPT-S1-8519-22
1900 PCS
1930-1995
1850-1915
2100 AWS
2110-2155
1710-1755
700 Upper C
746-756
776-786
700 Lower ABC 728-746
698-716
1 See power per carrier of HP MRAU from Table 6 on page 23.
Page 22
© 2012 TE Connectivity Ltd
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Composite Power Out of RAU
Table 6.
High Power Level: High Power MRAU with High Power SRAUs
Power per Carrier (dBm) per
Band
RF Frequency
TX
RX
Number of RF Carriers
P-out
P-out
P-Out P-out
26.0
20.0
14.0
9.0
GSM
23.0
17.5
12.0
8.0
EDGE
18.0
15.0
12.0
9.0
CDMA
18.0
15.0
12.0
9.0
WCDMA
High Power SRAUs
18.0
15.0
12.0
9.0
LTE
• SPT-S3-70AWS-11-HP
• SPT-S3-70AWS-22-HP
• SPT-S3-8519-22-HP
17.5
14.0
10.0
6.5
iDEN
26.0
19.5
13.5
8.5
APCO 25 C4FM
18.0
15.0
12.0
9.0
CDMA
18.0
15.0
12.0
9.0
LTE
17.5
14.0
10.0
6.5
iDEN
26.0
19.5
13.5
8.5
APCO 25 C4FM
26.0
23.0
19.0
14.0
GSM
26.0
22.5
17.0
13.0
EDGE
23.0
20.0
17.0
14.0
CDMA
23.0
20.0
17.0
14.0
WCDMA
23.0
20.0
17.0
14.0
LTE
23.0
20.0
17.0
14.0
WCDMA
23.0
20.0
17.0
14.0
LTE
18.0
15.0
12.0
9.0
LTE
High Power MRAU
• SPT-M3-8519-11-HP
850 Cell
800 SMR
900 SMR
1900 PCS
869-894
851-869
935-940
1930-1995
824-849
806-824
896-901
1850-1915
2100 AWS
2110-2155
1710-1755
700 Upper C
746-756
776-786
700 Lower ABC 728-746
698-716
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 23
© 2012 TE Connectivity Ltd.
Appendix B: 75-Ohm CATV Cable
APPENDIX B: 75‐OHM CATV CABLE
The 75‐Ohm CATV Cable:
•
connects the IFEU to MRAU(s) and the MRAU(s) to the SRAU(s)
•
transmits (FWD) multiband and receives (REV) IF signals
•
delivers DC electrical power to the RAUs. The Spectrum IFEU DC voltage output is +54Vdc
nominal. If the IFEU reaches its current limit, a current‐limiting circuit protects it.
•
carries configuration and status information
•
uses 75 type‐F connectors with captive center pins.
CATV Cable Requirements
Belden CATV cable or equivalent is required (see Figure 2).
•
For the RG‐6 cable, use a Belden 1695A Coax.
•
For the RG‐11 cable, use a Belden 7732A Coax.
NOTE:
TE Connectivity requires solid copper center conductor CATV cable for proper DC voltage to the
RAU and maximum distances.
RG-6
RG-11
Belden 1695A Coax
Belden 7732A Coax
Figure 2. Belden 1695A and 7732A Coax Cables
•
Use RG‐6 or RG‐11 CATV cable between the IFEU and MRAU, the typical lengths of which are
listed below.
Minimum Length Maximum Length
Cable Type
Page 24
© 2012 TE Connectivity Ltd
Meters
Feet
Meters
Feet
RG-6
125
410
RG-11
180
590
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Belden 1695A Coax Specifications
•
Use only RG‐6 CATV cable between the MRAU and SRAU, the lengths of which are listed below.
RG-6 Cable
Meters Feet
Typical
6.56
800/900 iDEN to 850 CELL
19.68
800 AWS to 850 CELL
19.68
Belden 1695A Coax Specifications
Description
RG‐6/U type, 18 AWG solid 0.040‐inch bare copper conductor, plenum, foam FEP insulation,
Duofoil® + tinned copper braid shield (95% coverage), Flamarrest® jacket.
Overall Physical Characteristics
Conductor
One Coax
18 AWG
Solid stranding
Bare Copper (BC) conductor material
0.040‐inch diameter
Insulation
Teflon®
Foam Fluorinated Ethylene Propylene (FFEP)
0.170‐inch diameter
Outer Shield Layer 1
Duofoil®
Tape
Aluminum Foil‐Polyester Tape‐Aluminum Foil
100% coverage
Outer Shield Layer 2
Braid
Tinned Copper (TC)
95% coverage
Outer Jacket
Flamarrest®
Low Smoke Polyvinyl Chloride (LS PVC)
Overall Cabling
0.234‐inch overall nominal diameter
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 25
© 2012 TE Connectivity Ltd.
Appendix B: 75-Ohm CATV Cable
Overall Nominal Electrical Characteristics
Characteristic Impedance
75.000
Inductance
0.103 H/ft.
Capacitance Conductor to Shield
16.100 (pF/ft.)
Velocity of Propagation
82 (%)
Delay
1.240 (ns/ft.)
Conductor DC Resistance
6.400 @ 20°C (/1000 ft.)
Outer Shield DC Resistance
2.800 @ 20°C (/1000 ft.)
Attenuation
Freq. (MHz) Attenuation (dB/100 ft.)
Page 26
© 2012 TE Connectivity Ltd
1.000
0.240
3.580
0.450
5.000
0.550
7.000
0.650
10.000
0.750
67.500
1.740
71.500
1.780
88.500
1.940
100.000
2.100
135.000
2.400
143.000
2.500
180.000
2.800
270.000
3.400
360.000
4.000
540.000
5.200
720.000
6.100
750.000
6.200
1000.000
7.300
1500.000
9.200
2000.000
10.900
2250.000
11.600
3000.000
13.700
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Belden 7732A Coax Specifications
Belden 7732A Coax Specifications
Description
RG‐11/U type, 14 AWG solid 0.064‐inch bare copper conductor, plenum, foam FEP insulation,
Duofoil® + tinned copper braid shield (95% coverage), fluorocopolymer jacket.
Overall Physical Characteristics
Conductor
One Coax
18 AWG
Solid stranding
Bare Copper (BC) conductor material
0.064‐inch diameter
Insulation
Teflon®
Foam Fluorinated Ethylene Propylene (FFEP)
0.274‐inch diameter
Outer Shield Layer 1
Duofoil®
Tape
Aluminum Foil‐Polyester Tape‐Aluminum Foil
100% coverage
Outer Shield Layer 2
Braid
Tinned Copper (TC)
95% coverage
Outer Jacket
Fluorocopolymer (PVDF)
Overall Cabling
0.348‐inch overall nominal diameter
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 27
© 2012 TE Connectivity Ltd.
Appendix B: 75-Ohm CATV Cable
Overall Nominal Electrical Characteristics
Characteristic Impedance
75.000
Inductance
0.091 H/ft.
Capacitance Conductor to Shield
16.300 (pF/ft.)
Velocity of Propagation
83 (%)
Delay
1.220 (ns/ft.)
Conductor DC Resistance
2.500 @ 20°C (/1000 ft.)
Outer Shield DC Resistance
1.600 @ 20°C (/1000 ft.)
Attenuation
Freq. (MHz) Attenuation (dB/100 ft.)
Page 28
© 2012 TE Connectivity Ltd
1.000
0.150
3.580
0.260
5.000
0.300
7.000
0.340
10.000
0.400
67.500
1.200
71.500
1.240
88.500
1.400
100.000
1.500
135.000
1.780
143.000
1.840
180.000
2.090
270.000
2.600
360.000
3.100
540.000
3.890
720.000
4.570
750.000
4.680
1000.000
5.500
1500.000
6.910
2000.000
8.130
2250.000
9.200
3000.000
10.200
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Belden 7732A Coax Specifications
APPENDIX C: OMNI ANTENNA
The Omni Antenna (4214‐0727), shown in Figure 3, is a round radome with the following
specifications:
Figure 3. Omni Antenna
Gain, typical
Port 1
2 dBi @ 698-960 MHz
Port 2
2 dBi @ 698-960 MHz
Port 3
3 dBi @1710-2170 MHz
3 dBi @ 1710-2170 MHz
3 dBi @ 1710-2170 MHz
3 dBi @ 2496-2690 MHz
Nominal impedance
50 Ohm
Polarization
Vertical
VSWR
< 2:1
Port-to-port isolation
>15 dB min, 22 dB typical
Power rating
5 Watt
Mechanical
Dimension of Antenna (DxH)
215 x 72 mm
Weight
Less than or equal to 1.65 lbs (0.75kg), including pigtails
Connector
N (male)
Cable (pigtail) length
6 feet, plenum rated cable
Color
White, UV protected plastic for outdoor use
Mounting hardware
Screws, anchor, and butterfly nut for ceiling tile mount
Environmental
Operating temperature
- 40°C to + 65°C
Shipping and Handling
ISTA Procedure 1A
Ingress protection
IP-42
Flammability
UL94V0 (Materials)
Compliance
ROHS compliant
NOTE:
Two antennas per RAU is required for MIMO performance.
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012
Page 29
© 2012 TE Connectivity Ltd.
Appendix D: Contacting TE Connectivity
APPENDIX D: CONTACTING TE CONNECTIVITY
Contacting TE Connectivity by Telephone
Sales
Asia Pacific
+65-6294-9948
France
0800 914032
Germany
0180 2232923
Italy
0800 782374
Spain
900 983291
United Kingdom
0800 960236
USA or Canada
1-800-366-3891
Extension
73000
Connectivity Extension
73475
Wireless Extension
73476
Technical Support
USA or Canada
1-800-530-9960
Elsewhere
+1-952-917-0761
Online Access to TE Connectivity
Customer Portal
https://www.te.com/commerce/uso/myaccount.do
Technical Support for Wireless Products
http://www.te.com/WirelessSupport
Page 30
© 2012 TE Connectivity Ltd
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • November 2012


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Page Count                      : 33
Page Mode                       : UseOutlines
Language                        : en
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:00c8d90e-2999-448f-962f-e2e6f283b6c0
Producer                        : Acrobat Distiller 10.1.4 (Windows)
Keywords                        : TECP-77-222
Creator Tool                    : FrameMaker 10.0.2
Modify Date                     : 2013:01:11 16:30:21+08:00
Create Date                     : 2012:11:27 15:15:15Z
Metadata Date                   : 2013:01:11 16:30:21+08:00
Document ID                     : uuid:af7213ba-56fe-4000-8d89-8002ef85c5e2
Instance ID                     : uuid:27f57f98-c82a-43ee-b7a9-4576c77ed357
Format                          : application/pdf
Title                           : InterReach Spectrum Remote Access Unit Installation Guide