ADRF KOREA FIRE-78-4 Repeater User Manual FiRe 78 4 Installation and Operating Manual

ADRF KOREA, Inc. Repeater FiRe 78 4 Installation and Operating Manual

FiRe-78-4 Installation User Manual v0.2 (2018.01.09)_Rev.1

Download: ADRF KOREA FIRE-78-4 Repeater User Manual FiRe 78 4 Installation and Operating Manual
Mirror Download [FCC.gov]ADRF KOREA FIRE-78-4 Repeater User Manual FiRe 78 4 Installation and Operating Manual
Document ID3738026
Application IDuOrNeSlJYS/jETy26crncQ==
Document DescriptionFiRe-78-4 Installation User Manual v0.2 (2018.01.09)_Rev.1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize109.03kB (1362922 bits)
Date Submitted2018-02-02 00:00:00
Date Available2018-08-01 00:00:00
Creation Date2018-01-30 16:56:33
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2018-01-30 16:56:46
Document TitleFiRe-78-4 Installation and Operating Manual
Document CreatorWordìš© Acrobat PDFMaker 11
Document Author: YH Ko

FiRe-78-4 Installation and Operating
Manual
Version 0.2
3116 West Vanowen St.
Burbank, CA 91505
Tel: 818-840-8131
Fax: 818-840-8138
www.adrftech.com
Advanced RF Technologies, Inc.
Information in this document is subject to change without notice.
Advanced RF Technologies, Inc. 1996-2015.
All rights reserved.
• Please send comments to:
E-Mail:
Phone:
Fax:
info@adrftech.com
(818) 840-8131
(800) 313-9345
(818) 840-8138
• Address:
Advanced RF Technologies, Inc.
Attention: Technical Publications Department
3116 Vanowen St.
Burbank, CA 91505
USA
www.adrftech.com
Advanced RF Technologies, Inc.
ii
Revision History
Version
0.1
0.2
Author
YH Ko
CK CHO
Descriptions
Date
Initial Release
Update
2017/11/17
2018/01/09
Change List
Version
Change list
Advanced RF Technologies, Inc.
Contents
iii
Table of Contents
1.
2.
3.
Introduction ........................................................................................................................................................6
1.1
Highlights .....................................................................................................................................................6
1.2
Quick View ...................................................................................................................................................7
1.3
Warnings and Hazards .................................................................................................................................8
Topology ...........................................................................................................................................................12
Cable Connection ..............................................................................................................................................12
3.1
AC Power ...................................................................................................................................................12
3.2
External Alarm ...........................................................................................................................................13
3.3
RF ...............................................................................................................................................................13
3.4
Optic ..........................................................................................................................................................14
3.5
Battery .......................................................................................................................................................15
3.6
Grounding ..................................................................................................................................................15
4.
RF EXPOSURE WARNING ...................................................................................................................................16
5.
Installation ........................................................................................................................................................17
6.
default items .....................................................................................................................................................17
7.
Specifications ....................................................................................................................................................17
7.1
Electrical Specifications .............................................................................................................................18
7.2
Mechanical Specifications..........................................................................................................................19
Figures
Figure 1-1
Figure 2-1
Figure 3-1
Figure 3-2
Figure 3-3
Figure 3-4
Figure 3-5
Figure 3-6
Figure 3-7
FiRe-78-4 Quick View (front and bottom) ............................................................................................7
FiRe-78-4 DAS topology ......................................................................................................................12
AC Power port.....................................................................................................................................12
External Alarm port ............................................................................................................................13
RF port ................................................................................................................................................13
Optic port............................................................................................................................................14
Optic Connector Cleaning (left) and Optic Port Cleaning (right) ........................................................14
SC/APC Optic Connector Dust Cap .....................................................................................................15
Protective Earthing Conductor ...........................................................................................................16
Advanced RF Technologies, Inc.
iv
Terms and Abbreviations
The following is a list of abbreviations and terms used throughout this document.
Abbreviation/Term
AGC
ALC
AROMS
BCU
BTS
BDA
CDMA
CHC
CW
DAS
DL
Downlink
HE
HPA
HW
IF
LNA
LTE
MS
NMS
ODU
OEU
PLL
POI
PSU
RF
RU
RM
SW
UL
Uplink
VSWR
Definition
Automatic Gain Control
Automatic Level Control
ADRF’ Repeater Operation and Management System
Band Combiner Unit
Base Transceiver Station
Bi-directional Amplifier
Code Division Multiple Access
Channel combiner
Continuous Wave (un-modulated signal)
Distributed Antenna System
Downlink
The path covered from the Base Transceiver Station (BTS) to the subscribers’ service area
via the repeater
Head End
High Power Amplifier
Hardware
Intermediate Frequency
Low Noise Amplifier
Long Term Evolution
Mobile Station
Network Management System
Optical Donor Unit which is located in ADXV-HE.
Optic Expansion Unit
Phased Locked Loop
Point Of Interface
Power Supply Unit
Radio Frequency
Remote Unit which is composed of master RU and multiple slaves RU
Remote Module
Software
Uplink
The path covered from the subscribers’ service area to the Base Transceiver Station (BTS)
via the repeater
Voltage Standing Wave Ratio
Advanced RF Technologies, Inc.
1.
INTRODUCTION
FiRe-78-4 which is the wireless Head end of Distributed Antenna System for VHF/UHF band has roles which interfaces
with Base Station via wireless and optically distributes by connection with multiple ADXV-R-3378P-N4X, which is one
of the ADRF’s DAS product lineups, via optic lines.
1.1 Highlights
•
Head end supporting 700MHz, 800MHz and Public Safety service band of DAS connected through optic line to
ADXV-R-3378P-N4X playing a role of Remote unit of DAS for 700/800MHz/Public Safety band
•
Fanless
•
Supports a total of 2 wide band and up to 32 non-contiguous narrow band channels (700MHz + 800MHz PS)
•
Air convection cooling without fans
•
Sharp Filter Roll-off performance (Wide: 60dBc @ Filter Bandwidth Edge + 1MHz | Narrow: 55dBc @ Filter
Bandwidth Edge + 3 * Filter BW)
•
Supports SNMP v1, v2c, v3 (get, set, & traps)
•
Web-based GUI Interface; No 3rd party GUI software required
•
Web-GUI connectivity via DHCP in host mode
•
External Alarm Function supporting dry contacts, 11 outputs and 1 input
Advanced RF Technologies, Inc.
1.2 Quick View
Figure 1-1
Advanced RF Technologies, Inc.
FiRe-78-4 Quick View (front and bottom)
1.3 Warnings and Hazards
WARNING! ELECTRIC SHOCK
Opening the PSR-VU-9537 could result in electric shock and may cause
severe injury.
WARNING! EXPOSURE TO RF
Working with the PSR-VU-9537 while in operation, may expose the technician to RF
electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at
www.fcc.gov/oet/rfsafety to learn more about the effects of exposure to RF electromagnetic
fields.
RF EXPOSURE & ANTENNA PLACEMENT Guidelines
Actual separation distance is determined upon gain of antenna used.
Please maintain a minimum safe distance of at least 200 cm while operating near the donor and
the server antennas.
WARRANTY
Opening or tampering the FiRe -78-4 will void all warranties.
Advanced RF Technologies, Inc.
Lithium Battery: CAUTION. RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO INSTRUCTIONS.
Preclude indications that Home/ personal use are prohibited.
Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP is
prohibited.
FCC Part 15 Class B
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at their own
expense.
FCC Part 90 Class A
WARNING. THIS is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and
QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to
operate this device. You MUST register Class A signal boosters (as defined in 47 CFR 90.219) online
at
www.fcc.gov/signal-boosters/registration. Unauthorized use may result in significant forfeiture
penalties, including penalties in excess of $100,000 for each continuing violation.
This device is only for Class A. According to FCC/ISED requirement, the passband of a Class B booster (except for
DAS boosters installed in buildings) should not encompass CMRS along with part 90 PLMRS and/or PSRS.
Advanced RF Technologies, Inc.
Part 90.635 requirement
Antennas must be installed in accordance with FCC 90.635. With 17 dBi gain antennas the height of
the antenna above average terrain (HAAT) must not exceed 85 m. For different gain antennas refer
to the relevant rules.
WARRANTY
This is NOT a CONSUMER device. It is designed for installation by an installer approved by
an ISED licensee. You MUST have an ISED LICENCE or the express consent of an ISED
licensee to operate this device.
FCC Part 15.21
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate this equipment.
RSS-GEN, Sec. 7.1.2– (transmitters)
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type
and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut
fonctionneravec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur
par Industrie Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres utilisateurs,
il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée quivalente
(p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
Advanced RF Technologies, Inc.
10
RSS-GEN, Sec. 7.1.2– (detachable antennas)
This radio transmitter (identify the device by certification number, or model number if Category II)has
been approved by Industry Canada to operate with the antenna types listed below with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not
included in this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de
modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner
avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance
requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain
est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
RF Radiation Exposure
This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 200 cm between the
radiator and your body. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter. RF exposure will be addressed at time of installation and the use of
higher gain antennas require larger separation distances.
RSS-102 RF Exposure
L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance
minimum de au moins 200 cm entre la source de radiation (l’antenne) et toute personne physique.
Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur.
Advanced RF Technologies, Inc.
11
2.
TOPOLOGY
ADXV-R-3378P-N4X
OPTIC
FiRe-78-4
Base
Station
SERVER
AC IN
100-240V
OPTIC
GUI
BATTERY
EF-UL IN EF-UL OUT EF-DL OUT EF-DL IN
ADRF-BBU ONLY
ADXV-R-3378P-N4X
DONOR_CPL
(-30dB)
AC 100-240V
OPTIC
OPTIC
DONOR
EXT_DL
GUI
EXT_UL
Ext. ALARM
SERVER
AC IN
100-240V
BATTERY
ADRF-BBU ONLY
OPTIC
GUI
BATTERY
EF-UL IN EF-UL OUT EF-DL OUT EF-DL IN
ADRF-BBU ONLY
ADXV-R-3378P-N4X
OPTIC
SERVER
AC IN
100-240V
OPTIC
GUI
BATTERY
EF-UL IN EF-UL OUT EF-DL OUT EF-DL IN
ADRF-BBU ONLY
ADXV-R-3378P-N4X
OPTIC
SERVER
AC IN
100-240V
Figure 2-1
3.
OPTIC
GUI
BATTERY
EF-UL IN EF-UL OUT EF-DL OUT EF-DL IN
ADRF-BBU ONLY
FiRe-78-4 DAS topology
CABLE CONNECTION
3.1 AC Power
Figure 3-1
AC Power port
AC power is accepted through a standard 3-wire male plug (MS3106A-22-2S) with phase, neutral and ground leads.
The AC power is wired to a high efficiency DC switching power supply which is UL listed. The power supply runs the
amplifiers and device including RF Module, controller, LED, etc.
The metal enclosure of this equipment is connected to ground.
Advanced RF Technologies, Inc.
12
3.2 External Alarm
Figure 3-2
External Alarm port
This port should be connected only to ADRF External Alarm Box.
3.3 RF
Figure 3-3
RF port
The RF connections are made via three “4.3-10” female connectors. The RF connector labeled “DONOR” must be
connected to each antenna pointing towards the base station.
The RF connections must be made through cables with characteristic impedance of 50 ohms.
Advanced RF Technologies, Inc.
13
3.4 Optic
ODU
LINK4
LINK3
LINK2
LINK1
SC/APC
Adpator
OPTIC
Inside of Fire-78-4
Conduit for optic
(Conduit connector)
Figure 3-4
Optic port
ODU located inside of equipment has 4 optic ports (SC/APC type) for link to ADXV-R-3378P-N4Xs.
You must verify to keep optic contact be clean and optic line’s curvature be not allowed in order to be free from
optic loss when you install optic line and conduit.
• We recommend cleaning optic connector using a dry optical cleaning swab or tissue in a dry environment
as needed. We recommend cleaning the optic connectors only if the expected optic loss is higher than
the loss reported in the Web-GUI by 1.5dBo. (Figure 3-5)
• When optic connector are not in use, the port should be covered with a protective dust cap. (Figure 3-6)
•
•
Figure 3-5
Optic Connector Cleaning (left) and Optic Port Cleaning (right)
Advanced RF Technologies, Inc.
14
•
•
Figure 3-6
SC/APC Optic Connector Dust Cap
3.5 Battery
This port should be connected to ADRF 24VDC BBU (Battery back-up unit) via dedicated cable provided by ADRF.
3.6 Grounding
A ground cable is included in the box. The grounding terminals are located at lower right-hand side of the
equipment. The grounding cable should be properly connected before powering on the equipment.
Advanced RF Technologies, Inc.
15
Figure 3-7
Protective Earthing Conductor
Ground terminals located on the side consisted of a 16mm²(6AWG) and should be permanently connected to
earth(Protective earthing conductor).
4.
RF EXPOSURE WARNING
In order to comply with the FCC RF exposure requirements, the antenna installation must comply with the following:
The outdoor antenna (Yagi type or similar directional antenna if off air donor signal used) must be installed so as to
provide a minimum separation distance of 0.3 meters (60 cm) between the antenna and persons within the area.
(This assumes a typical antenna with gain of [10.1 dBi, VSWR ≤ 1.5:1, Zo= 50 ohms, and a cable attenuation between
1-10 dB).
The indoor antenna (Omni directional or leaky cable) must be installed so as to provide a minimum separation
distance of at least 8 inches (20 cm) between the indoor antenna connected to the RF booster and the human user’s
Advanced RF Technologies, Inc.
16
body within the area. (This assumes a typical wide beam type antenna with gain of 0-2 dBi, VSWR ≤ 2:1, Zo= 50
ohms, and a cable attenuation of between 1-10 dB).
5.
INSTALLATION
DO NOT APPLY A.C. POWER TO THE BDA UNTIL CABLES ARE CONNECTED TO BOTH PORTS OF
THE BDA AND THE ANTENNAS.
6.
1.
To mount on a wall. Using appropriate screws and anchors, attach the BDA to the wall at the four mounting
holes
2.
Ensure that the isolation between the donor antenna and the service antenna is at least 15 dB greater than
the BDA gain.
3.
Connect the cable from the donor antenna to the BDA connector labeled “DONOR” and the cable from the
service antennas to the BDA connector labeled “SERVER”.
4.
Connect the AC power cord to the BDA and turn on the switch at the left-hand of PSU.
5.
Installation of the equipment is now complete. Adjust the gain controls to suit the specific signal
environment through GUI on your PC.
To prevent feedback, the donor and server antennas must be separated by an appropriate distance to
provide sufficient isolation. Isolation is attained by separating antennas a sufficient distance so that the
output of one antenna does not reach the input of the other. This distance is dependent on the gain of the
repeater.
Prior to equipment use the service must be registered with the FCC. This can be done through the FCC’s
website at https://signalboosters.fcc.gov/signal-boosters)
DEFAULT ITEMS
Items
Antenna
Cable
Coupling device
7.
Model name
SPECIFICATIONS
Advanced RF Technologies, Inc.
17
7.1 Electrical Specifications
Specifications
Parameters
Frequency Range
(MHz)
Composite Output
Power of FiRe-78-4
PS 700
PS 800
PS 700
PS 800
PS 700 + PS 800
Composite Output PS 700
Power of FiRe-78PS 800
4+ADXV-R-78PS
System total Gain (dB)
[FiRe-78-4+ ADXV-R-3378P-N4X]
System total Input power
[FiRe-78-4+ADXV-R-3378P-N4X]
Filter selection
Simultaneous Filter
Support numbers
DL
UL
769 - 775MHz(For FCC)
(768-769MHz Guard
band)
768 - 775 MHz (For ISED)
799 - 805 MHz(For FCC)
(798- 799MHz Guard
band)
798- 805 MHz (For ISED)
-24dBm
30dBm
33dBm
30dBm
33dBm
30dBm
95
85
-62dBm
-55dBm
851 - 861
-24dBm
-24dBm
806 - 816
30dBm
30dBm
Narrow(kHz)
Narrow
Up to 16(Non-contiguous) @ PS 700 / PS 800
Up to 32(Non-contiguous) @ PS 700 + PS 800
6.25, 12.5, 25
Narrow(kHz)
≥ 60dBc@Filter Bandwidth Edge + 3 x Filter BW
Narrow Band
Spurious
Passband Ripple
ALC Dynamic Range
Gain Dynamic Range
Channel Setting Resolution
Broad Band
System
Group Delay
Narrow Band
Power Supply
FCC Rule Compliant
±2 dB
≥ 60dB
≥ 40dB
0.025 kHz
<6.5us
≤85us@6.25KHz_BW
≤46us@12.5KHz_BW
≤28us@25KHz _BW
100 -240 VAC, 60Hz (Free Voltage)
Power Consumption
<135Watt
Max RF Input Power without over drive
UL Noise Figure @ Max. Gain
No damage Max Input Power
Enclosure Cooling
Impedance
VSWR
-20dBm
5.0dB Center Frequency
+10dBm
Natural Convection
50 Ω
<1.5 : 1
ODU number per NEMA4-x
1 ODUs(; max 4 RUs)
Dry Contacts
NFPA 72 2016 Code Compliant
Remote Alarming /
Network Management
Relative Humidity
Operating Temperature
Dry Contacts, Web-GUI, SNMP, SNMP-Traps
(External Wireless Modem Required)
5% - 90%
-40°F to +140°F (-40°C to +60°C)
Compliant
NFPA 1221 2016 Code Compliancy
Advanced RF Technologies, Inc.
Remarks
DL Path Only
Except of optic cable delay,
Except of ADXV-R-3378P-N4X
With battery backup,
[ADXV-R-3378P-N4X+ FiRe-78-4]
DL Path Only
DL/UL Input
18
7.2 Mechanical Specifications
Dimensions W x D x H
Weight
11.03 x 21.28 x 10.01 inches
60.5lbs (without mount bracket)
64.0lbs (with mount bracket)
RF Connector
4.3-10(Female)
Expansion port for V/UHF
2 SMA(Female) port
Weather Resistances
IP66
Optic terminal tray(; inside)
Advanced RF Technologies, Inc.
without mount bracket
4 optic cables per optic tray in the
enclosure
19
8. FiRe-78-4 Web-GUI Setup
The Web-GUI allows the user to communicate with the repeater either locally or remotely. To connect to the
repeater locally, you will need a laptop with an Ethernet port and an RJ-45 crossover cable. To connect to the
repeater remotely, you will need to have an active internet connection via an external modem or LAN.
8.1 Repeater/PC Connection Using Web-GUI
Verify that your Local Area Network Connection is set to obtain an IP address automatically under the Internet
Protocol (TCP/IP) properties.
If you are connecting to the unit remotely (use of a modem), then skip step above.
Connect the RJ-45 crossover cable between the laptop’s Ethernet port and the repeater’s Ethernet port.
Launch an Internet Browser.
Type the following IP address into the address bar of the Internet Browser: http://192.168.63.1
If you are connecting to the unit remotely, then type the IP address of the modem to connect to the unit
The following login screen will appear:
• Figure 5-1 Login Page
If you are not the Administrator, please type in your assigned username & password which you should have
received from the Administrator.
The default username and password for the General User is adrf & adrf, respectively.
The default Administrator login is admin & admin, respectively.
Advanced RF Technologies, Inc.
20
8.2 Status Tab
•
Advanced RF Technologies, Inc.
Figure 5-2
Status Tab
21
8.2.1
Navigation Tree
The navigation tree located on the left hand side of the Web-GUI allows the user to switch between the
various modules that are connected to the system.
Table 7-1
Parameters
Navigation tree
Description
Expands the entire navigation tree
Collapses the entire navigation tree
The module has the expandable subordinate modules
The branch is currently expanded
The module has soft fail alarm
The module has hard fail alarm
The module has no alarms (normal)
The selected module will have bright gray color
8.2.2
System Summary
Table 7-2 System Summary Description
Parameters
Description
Connected
Display the number of modules physically connected to ADXV DAS
Soft Fail
Display the number of soft fail present on each module
Hard Fail
Display the number of hard fail present on each module
Link Fail
Display the number of link fail present on each module
Not Commissioned
Display the number of non-commissioned or commission failed module
Commissioned
Display the number of successfully commissioned module
8.2.3
Band Info
The Band Info section displays frequency information along with the corresponding bandwidths that have been
set from the Install tab. Input levels for each channel are also displayed in this section.
Advanced RF Technologies, Inc.
22
•
Figure 5-3
Band Info Display
8.2.4
Power & Gain
This section displays the Input, Gain, and Output for both downlink and uplink.
• Figure 5-4 Power & Gain Display
Input [dBm] – Displays the in-band Downlink/Uplink signal level. The system will display “--.-“ when the input
level is < -90 dBm.
Outband [dBm] – Displays the out-band composite power.
Gain [dB]
User Set: Displays the amount of gain that the user set.
Actual: Displays the actual amount of gain that is currently in use.
Output [dB] – Displays the Downlink/Uplink composite output power levels. The system will display “--.-“, when
the output level is < +5 dBm.
Advanced RF Technologies, Inc.
23
8.2.5
Alarms
This section displays the alarm status for System alarms, RF Alarms, and Power alarms. If an alarm is present in
the system, then the color of the alarm tab will change according to the type of failure.
•
8.2.6
Figure 5-5
Alarm Display
Repeater Info / Repeater Location / Technical Support / Installer Contact Info
• Figure 5-6 Repeater Info / Repeater Location / Technical Support / Installer Contact Info
Repeater Info: Displays the serial number, latitude, longitude, firmware version, and Web-GUI version
Repeater Location: Displays the address where the repeater is installed
Technical Support: Displays ADRF’s Technical Support contact information
Installer Contact Info: Displays the installer’s name, phone, and e-mail address
Note: Once successfully logged in, the repeater model name and the site/cascade ID will be displayed on the
top of all the windows (except for the Main Window).
8.3 Control Tab
Advanced RF Technologies, Inc.
24
•
Advanced RF Technologies, Inc.
Figure 5-7
Control page
25
8.3.1
General Setting
The General Setting section allows the user to enable/disable amplifiers and the ALC routine.
• Figure 5-8 General Setting
ALC ON: Enables or disables Automatic Level Control (ALC)
PSR 700 DL HPA On: Enables or disables the Downlink High Power Amplifier (HPA) for 700MHz PS
PSR 800 DL HPA On: Enables or disables the Downlink High Power Amplifier (HPA) for 800MHz PS
PSR 700+800 UL HPA On: Enables or disables the Uplink High Power Amplifier (HPA) for 700+800MHz PS
To enable/disable any of the settings, click on the checkbox and click the Apply button.
8.3.2
System
Under the System section, the user is able to perform soft reboot on the repeater and also can restore factory
default settings.
• Figure 5-9
Reboot: Performs a soft reboot of the repeater
Factory Set: Restores all settings to factory defaults
8.3.3
System
Manual Gain Control
• Figure 5-10 Manual Gain Control Setting
DL/UL Gain: Gain levels of the repeater can be specified here
DL/UL ALC Level: Prevents the output power from exceeding the specified value
DL/UL Output ALC Offset: If any ALC attenuation has been applied, the system will release this attenuation
when the signal level drops by the specified level
DL /UL Gain Balance ON: Allows the user to enable or disable the gain balance. When gain balance is enabled,
the delta value between the downlink and uplink gains remain constant
Advanced RF Technologies, Inc.
26
8.3.4
Alarm Settings
• Figure 5-11 Alarm Settings
DL Signal Low Level: Allows the user to specify how low the signal can be before triggering a “Downlink Signal
Low” soft-fail alarm
DL Signal Not Detected Level: Allows the user to specify how low the signal can be before triggering a “Downlink
Signal Not Detected” soft-fail alarm
DL RF Power Level: Allows the user to set a maximum deviation value for the downlink RF power before
triggering a “DL RF Power Level” soft-fail alarm
For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power should be 10
dBm. If the Downlink RF Power alarm value is set to 6dB, then a soft-fail alarm will trigger if the output power falls
below 4 dBm
DL Over Power Level: DL Over Power Alarm will trigger when the DL output level exceeds this level
UL Over Power Level: UL Over Power Alarm will trigger when the UL output level exceeds this level
Battery Check:
• Check All – All battery related alarms are checked which include Battery Fail, Battery Not Installed, Low
Battery, and Battery Not Charge
• Except Install – Only Battery Fail, Low Battery, and Battery Not Charge alarms are checked
• Check Off – Does not perform any battery check
Battery Not Charge Check:
• On – Checks for the Battery Not Charge alarm
• Off – Disables the check for the Battery Not Charge alarm
Advanced RF Technologies, Inc.
27
8.4 Install Tab
8.4.1
Install
•
Advanced RF Technologies, Inc.
Figure 5-12 Install Page
28
8.4.2
Technology
This section allows the user to set the repeater mode to either use PS700, PS800, or PS700+PS800.
• Figure 5-13 Technology
The following choices are available from the dropdown:
• PS700 (769-775MHz)
• PS800 (851-861MHz)
• PS700+PS800 (769-861MHz)
8.4.3
Band Selection
• Figure 5-14 Band Selection
Band selection allows the user specify the desired frequncies by inputting the center frequencies and selecting
the bandwidths.
Reference Center Frequency: The user can input the center frequency of the pass-band.
Bandwidth: Allows the user to select the desired bandwidth for the passband. Choices for wide band
frequencies include 5 and 10MHz. Narrow band choices include 6.25, 12.5, 25.0, and 200 KHz.
Downlink/Uplink Gain: Minor gain adjustments can be performed on a per channel basis to equalize signal
levels
Downlink Freq - Start: Displays the start frequency of the pass-band once the band selection has been set
Downlink Freq - End: Displays the end frequency of the pass-band once the band selection has been set
8.4.4
SNMP
Advanced RF Technologies, Inc.
29
• Figure 5-15 SNMP
The SNMP section allows you to specify the Site ID and Description. The Site-ID is the code that is used to
identify the repeater.
8.4.5
Location
This section allows the user to input the latitude and the longitude of the repeater.
•
Figure 5-16 Location Setting
8.4.6
Modem Box Setting
This section allows the user to specify alternative Repeater IP, Subnet Mask, and Gateway settings. These
settings are enabled when the Host/Remote switch is set to the Remote position.
•
Figure 5-17 Modem Box Setting
8.4.7
AAI Input
The PSR-VU-9537 can accept a dry contact input alarms. The alarm can be labeled in this section. Once the
alarm is labeled, it will show up in the system with the new custom names on the Status tab.
•
Advanced RF Technologies, Inc.
Figure 5-18 AAI Input
30
8.4.8
Location Info / Installer Info
This section allows the user to specify the address of the repeater and also the information of the installer.
• Figure 5-19 Repeater Location Info / Repeater Installer Info
8.4.9
Date & Time
This section allows the user to specify the current date and time.
•
Advanced RF Technologies, Inc.
Figure 5-20 Date & Time Setting
31
8.5 System
The System tab allows the user to perform firmware updates, upload closeout packages, view any changes to
the system, backup existing configuration, and add/remove user accounts, and change the login credentials of the
Administrator.
8.5.1
System: Account
8.5.1.1 System: Account – Account Management
The Account Management section allows the Administrator to delete any user accounts. Please note that the
Account Management section is only available if you are logged into the system as the Administrator. To delete a
user account click on the Account Management link and under the Delete column, click on the delete button.
• Figure 5-21 System: Account- Account Management
8.5.1.2 System: Account – New Account
The New account section allows the Administrator to create a new user account. Please note that the New
account section is only available if you are logged into the system as the Administrator. To create a new user account
click on the new account link and fill in the fields shown.
Figure 5-22 System: Account- New Account
8.5.1.3 System: Account – Change Password
The Change Password section allows the current user who is logged into the system to change their login
credentials.
• Figure 5-23 System: Account- Change Password
8.5.2
System – User Log
This section displays system events that have taken place. The User Log displays who has made the changes,
the time and date of when the event took place, and what changes were made to the system.
Advanced RF Technologies, Inc.
32
•
Advanced RF Technologies, Inc.
Figure 5-24 System – User Log
33
8.5.3
System – Update
To perform a firmware update, click on the Update tab and the following screen will appear.
• Figure 5-25 System – Update
Click on the Choose File button and locate the firmware file.
Click on the Upgrade button to perform the firmware update.
8.5.4
System – Backup & Restore
The backup section allows the user to save the settings. To perform the backup, click on the Backup button and
system save the backup file. To restore the settings to the system, click on Choose File button, select the backup
file, restore unit and click the excute button.
Advanced RF Technologies, Inc.
34
•
Advanced RF Technologies, Inc.
Figure 5-26 System Backup
35
8.6 Help
If an internet connection is available, clicking on the Help Tab will redirect the user to our Technical Support
page.
• Figure 5-27 Help
8.7 Logout
Clicking the Logout button will log the current user off the system.
Advanced RF Technologies, Inc.
36

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : YH Ko
Company                         : ADRF Tech
Create Date                     : 2018:01:30 16:56:33+09:00
Modify Date                     : 2018:01:30 16:56:46+09:00
Source Modified                 : D:20180130075618
Version                         : 0.1
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Metadata Date                   : 2018:01:30 16:56:46+09:00
Creator Tool                    :  Word용 Acrobat PDFMaker 11
Document ID                     : uuid:314cb274-6e8f-4036-9159-31e1dfdb13cc
Instance ID                     : uuid:e97cdf49-c923-4cdf-8178-853f4499bbb5
Subject                         : 6
Format                          : application/pdf
Title                           : FiRe-78-4 Installation and Operating Manual
Creator                         : YH Ko
Producer                        : Adobe PDF Library 11.0
Page Layout                     : OneColumn
Page Count                      : 36
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N52-FIRE-78-4

Navigation menu