ADRF KOREA PSR-78-9533B Repeater User Manual AXMS8C 9543 ICS X MANUAL
ADRF KOREA, Inc. Repeater AXMS8C 9543 ICS X MANUAL
PSR-78-9533B_User Manual_v0.3_B9B_Rev.1
PSR-78-9533 MANUAL VERSION 0.3 3116 West Vanowen St. Burbank, CA 91505 Tel: 818-840-8131 Fax: 818-840-8138 www.adrftech.com Advanced RF Technologies, Inc. Information in this document is subject to change without notice. Advanced RF Technologies, Inc. 1996-2016. All rights reserved. Please send comments to: E-Mail: Phone: Fax: info@adrftech.com (818) 840-8131 (800) 313-9345 (818) 840-8138 Address: Advanced RF Technologies, Inc. Attention: Technical Publications Department 3116 Vanowen St. Burbank, CA 91505 USA www.adrftech.com Advanced RF Technologies, Inc. ii REVISION HISTORY Version 0.1 0.2 Author ADRF Ck Jo Descriptions Date Initial Release Revision Update 11/18/2016 01/17/2017 CHANGE LIST Version Change list Advanced RF Technologies, Inc. Contents iii TABLE OF CONTENTS 1. 2. Introduction ........................................................................................................................................................9 1.1 Highlights .....................................................................................................................................................9 1.2 Parts List.....................................................................................................................................................10 1.3 Quick View .................................................................................................................................................11 1.4 Warnings and Hazards ...............................................................................................................................12 Overview ...........................................................................................................................................................17 2.1 LED .............................................................................................................................................................17 2.2 Host / Remote Switch ................................................................................................................................17 2.3 Cable Connection .......................................................................................................................................18 2.3.1 AC Power ............................................................................................................................................18 2.3.2 External Alarm ....................................................................................................................................19 2.3.3 RF ........................................................................................................................................................20 2.3.4 Back Up Battery Port ..........................................................................................................................21 2.3.5 Grounding ...........................................................................................................................................22 2.3.6 Ethernet Port ......................................................................................................................................22 3. Alarms ...............................................................................................................................................................23 3.1 Message Board Alarms and Notifications ..................................................................................................23 3.2 Alarms ........................................................................................................................................................23 3.3 External Alarms ..........................................................................................................................................24 3.3.1 External Alarm Output interface ........................................................................................................24 3.3.2 External Alarm Input interface ...........................................................................................................25 4. Installation ........................................................................................................................................................26 4.1 Installation Procedures ..............................................................................................................................26 4.1.1 Wall Mount Procedure .......................................................................................................................26 4.2 5. Antenna Separation/Isolation....................................................................................................................27 PSR-78-9533 Web-GUI Setup ............................................................................................................................29 5.1 Repeater/PC Connection Using Web-GUI ..................................................................................................29 5.2 Status Tab ..................................................................................................................................................30 5.2.1 Band Info ............................................................................................................................................31 5.2.2 Power & Gain......................................................................................................................................31 5.2.3 Alarms .................................................................................................................................................32 5.2.4 Repeater Info / Repeater Location / Technical Support / Installer Contact Info................................32 5.3 Control Tab ................................................................................................................................................33 5.3.1 General Setting ...................................................................................................................................34 5.3.2 System ................................................................................................................................................34 5.3.3 Manual Gain Control ..........................................................................................................................34 5.3.4 Alarm Settings ....................................................................................................................................35 5.4 Install Tab...................................................................................................................................................36 5.4.1 Install ..................................................................................................................................................36 Advanced RF Technologies, Inc. iv 25.4.2 Technology .........................................................................................................................................37 5.4.3 Band Selection ....................................................................................................................................37 5.4.4 SNMP ..................................................................................................................................................38 5.4.5 Location ..............................................................................................................................................38 5.4.6 Modem Box Setting ............................................................................................................................38 5.4.7 AAI Input .............................................................................................................................................38 5.4.8 Location Info / Installer Info ...............................................................................................................39 5.4.9 Date & Time ........................................................................................................................................39 5.5 System .......................................................................................................................................................40 5.5.1 System: Account .................................................................................................................................40 5.5.1.1 System: Account – Account Management ................................................................................40 5.5.1.2 System: Account – New Account ..............................................................................................40 5.5.1.3 System: Account – Change Password .......................................................................................40 5.5.2 System – User Log ..............................................................................................................................40 5.5.3 System – Update ................................................................................................................................42 5.5.4 System – Backup & Restore ................................................................................................................42 6. 5.6 Help ............................................................................................................................................................43 5.7 Logout ........................................................................................................................................................43 Maintenance Guide for PSR-78-9533 Repeater ................................................................................................43 6.1 Periodic Inspection Checklist .....................................................................................................................43 6.2 Preventive Measures for Optimal Operation ............................................................................................43 6.2.1 Recommendations..............................................................................................................................43 6.2.2 Precautions .........................................................................................................................................43 7. 8. Warranty and Repair Policy ..............................................................................................................................44 7.1 General Warranty ......................................................................................................................................44 7.2 Limitations of Warranty .............................................................................................................................44 7.3 Limitation of Damages ...............................................................................................................................44 7.4 No Consequential Damages .......................................................................................................................44 7.5 Additional Limitation on Warranty ............................................................................................................44 7.6 Return Material Authorization (RMA) .......................................................................................................44 Specifications ....................................................................................................................................................45 8.1 Electrical Specifications .............................................................................................................................45 8.2 Mechanical Specifications..........................................................................................................................46 8.3 Power Specifications ..................................................................................................................................46 8.4 Environment Specifications ..................................................... 오류! 책갈피가 정의되어 있지 않습니다. 8.5 Warranty & Certificates .............................................................................................................................46 9. Mechanical Drawing .........................................................................................................................................47 10. Appendix ...........................................................................................................................................................48 10.1 Shutdown Retry Logic ................................................................................................................................48 Advanced RF Technologies, Inc. FIGURES Figure 1-1 Figure 1-2 Figure 2-1 Figure 2-2 Figure 2-3 Figure 2-4 Figure 2-5 Figure 2-6 Figure 2-7 Figure 2-8 Figure 2-9 Figure 2-10 Figure 4-1 Figure 4-2 Figure 5-1 Figure 5-2 Figure 5-3 Figure 5-4 Figure 5-5 Figure 5-6 Figure 5-7 Figure 5-8 Figure 5-9 Figure 5-10 Figure 5-11 Figure 5-12 Figure 5-13 Figure 5-14 Figure 5-15 Figure 5-16 Figure 5-17 Figure 5-18 Figure 5-19 Figure 5-20 Figure 5-21 Figure 5-22 Figure 5-23 Figure 5-24 Figure 5-25 Figure 5-26 Figure 5-27 Figure 5-28 Figure 9-1 PSR-78-9533 Repeater Parts List ........................................................................................................10 PSR-78-9533 Quick View (Bottom) .....................................................................................................11 LED Panel ............................................................................................................................................17 Host/Remote Switch...........................................................................................................................17 AC Input Port ......................................................................................................................................18 AC On/Off Switch ................................................................................................................................18 External Alarm port ............................................................................................................................19 RF ports ..............................................................................................................................................20 Battery Backup Port............................................................................................................................21 Battery Switch ....................................................................................................................................21 Ground Cable Terminal.......................................................................................................................22 Ethernet Port ......................................................................................................................................22 Wall Mount .........................................................................................................................................26 RF Repeater Oscillation ......................................................................................................................27 Login Page ..........................................................................................................................................29 Status Tab ...........................................................................................................................................30 Band Info Display ................................................................................................................................31 Power & Gain Display .........................................................................................................................31 Alarm Display ......................................................................................................................................32 Repeater Info / Repeater Location / Technical Support / Installer Contact Info................................32 Control page .......................................................................................................................................33 General Setting ...................................................................................................................................34 System ................................................................................................................................................34 Manual Gain Control Setting ..............................................................................................................34 Alarm Settings ....................................................................................................................................35 Install Page .........................................................................................................................................36 Technology .........................................................................................................................................37 Band Selection ....................................................................................................................................37 SNMP ..................................................................................................................................................38 Location Setting ..................................................................................................................................38 Modem Box Setting ............................................................................................................................38 AAI Input .............................................................................................................................................38 Repeater Location Info / Repeater Installer Info ................................................................................39 Date & Time Setting ...........................................................................................................................39 System: Account- Account Management ...........................................................................................40 System: Account- New Account .........................................................................................................40 System: Account- Change Password ..................................................................................................40 System – User Log ..............................................................................................................................41 System – Update ................................................................................................................................42 Pop-up Message after System Update is Complete ...........................................................................42 System Backup....................................................................................................................................42 Help ....................................................................................................................................................43 PSR-78-9533 Mechanical Drawing......................................................................................................47 Advanced RF Technologies, Inc. vi TABLES Table 1-1 Table 2-1 Table 2-2 Table 3-1 Table 3-2 Table 8-1 Table 8-2 Table 8-3 Parts List .............................................................................................................................................10 LED Specifications ...............................................................................................................................17 External Alarm Port Pin Description ...................................................................................................19 Message Board Alarms and Notifications...........................................................................................23 Alarms .................................................................................................................................................23 Electrical Specifications ......................................................................................................................45 Mechanical Specifications ..................................................................................................................46 Power Specifications ..........................................................................................................................46 Table 8-4 Table 8-5 Environment Specifications .............................................. 오류! 책갈피가 정의되어 있지 않습니다. Warranty & Certificates ......................................................................................................................46 Advanced RF Technologies, Inc. vii Terms and Abbreviations The following is a list of abbreviations and terms used throughout this document. Abbreviation/Term AGC ALC AROMS BDA BTS CDMA CFR CP CW DAS DL HPA HW IF LNA LTE MS OFDM OFDMA PAR (PAPR) PLL PSU QAM QPSK RB RF SC-FDMA SQE SW UE UL VSWR Definition Automatic Gain Control Automatic Level Control ADRF Repeater Operation and Management System Bi-Directional Amplifier Base Transceiver Station Code Division Multiple Access Crest Factor Reduction Cyclic Prefix Continuous Wave (un-modulated signal) Distributed Antenna System Downlink High Power Amplifier Hardware Intermediate Frequency Low Noise Amplifier Long Term Evolution Mobile Station Orthogonal Frequency-Division Multiplexing Orthogonal Frequency-Division Multiple Access Peak to Average Power Ratio (Crest Factor) Phase Locked Loop Power Supply Unit Quadrature Amplitude Modulation Quadrature Phase Shit Keying Resource Block Radio Frequency Single Carrier-Frequency Division Multiple Access Signal Quality Estimate Software User Equipment Uplink Voltage Standing Wave Ratio Advanced RF Technologies, Inc. 1. INTRODUCTION PSR-78-9533 bi-directional amplifier (BDA) extends the coverage area of radio communications in buildings and RF shadow environments. The unit features low noise figure and wide dynamic range. 1.1 Highlights • • • • • • • • Supports both 700MHz and 800MHz Public Safety Frequencies in a single repeater Supports a total of 2 wide band and up to 32 non-contiguous narrow band channels (700MHz + 800MHz PS) Air convection cooling without fans Sharp Filter Roll-off performance (Wide: 60dBc @ Filter Bandwidth Edge + 1MHz | Narrow: 55dBc @ Filter Bandwidth Edge + 3 * Filter BW) Supports SNMP v1, v2c, v3 (get, set, & traps) Web-based GUI Interface; No 3rd party GUI software required Web-GUI connectivity via DHCP in host mode External Alarm Function supporting dry contacts, 11 outputs and 1 input Advanced RF Technologies, Inc. 1.2 Parts List Table 1-1 Label Quantity Parts List Description PSR-78-9533 Wall Mount Bracket Mounting Bracket Template AAI Alarm Cable AC Power Cable Ethernet Cable (Crossover) Anchor Bolt Ground Cable Documentation CD Figure 1-1 Advanced RF Technologies, Inc. PSR-78-9533 Repeater Parts List 10 1.3 Quick View Ground Terminal Server Port (4.3-10 Female) Donor Port (4.3-10 Female) Sever CPL (DL Output Monitor Port,-30dB) Donor CPL (UL Output Monitor Port, -30dB) AAI Alarm Port Ethernet Port (RJ-45) ADRF-BBU Battery Port AC Input Port Air Vent Hole Heat Sink Figure 1-2 Advanced RF Technologies, Inc. PSR-78-9533 Quick View (Bottom) 11 1.4 Warnings and Hazards WARNING! ELECTRIC SHOCK Opening the PSR-78-9533 could result in electric shock and may cause severe injury. WARNING! EXPOSURE TO RF Working with the repeater while in operation, may expose the technician to RF electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at www.fcc.gov/oet/rfsafety to learn more about the effects of exposure to RF electromagnetic fields. WARNING! DAMAGE TO REPEATER Operating the PSR-78-9533 with antennas in very close proximity facing each other could lead to severe damage to the repeater. RF EXPOSURE & ANTENNA PLACEMENT Guidelines Actual separation distance is determined upon gain of antenna used. Please maintain a minimum safe distance of at least 200 cm while operating near the donor and the server antennas. Also, the donor antenna needs to be mounted outdoors on a permanent structure. WARRANTY Opening or tampering the PSR-78-9533 will void all warranties. Advanced RF Technologies, Inc. 12 Lithium Battery: CAUTION. RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO INSTRUCTIONS. Ethernet Instructions: This equipment is for indoor use only. All cabling should be limited to inside the building. Preclude indications that Home/ personal use are prohibited. Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP is prohibited. Regulatory Warning Statement FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 200cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case Advanced RF Technologies, Inc. 13 FCC Part 90 Class B WARNING. THIS is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. FCC Part 15.21 Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. RSS-GEN, Sec. 7.1.2– (transmitters) Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée quivalente (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Advanced RF Technologies, Inc. 14 RSS-GEN, Sec. 7.1.2– (detachable antennas) This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur. RF Radiation Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 200 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas require larger separation distances. Power Reduction Warning Statement This 3.5dB back off is only required when multiple carriers are present in the pass-band. Advanced RF Technologies, Inc. 15 Part 90.635 requirement Antennas must be installed in accordance with FCC 90.635. With 17 dBi gain antennas the height of the antenna above average terrain (HAAT) must not exceed 80 m. For different gain antennas refer to the relevant rules. ◈LABEL WARNING◈ Advanced RF Technologies, Inc. 16 2. 2.1 OVERVIEW LED PSR-78-9533 LED indicator lights are located on the inside of the repeater towards the bottom. Below the LED indicators is a button that is used to trigger the door open alarm. Figure 2-1 Table 2-1 LED Panel LED Specifications POWER DL UL ALARM AC Fail DL Signal Not Detected UL Out-Band Overload Power Related Alarms DC Fail DL Signal Low Detected UL Input Overload RF DL Path Related Alarms Battery Fail DL RF Power UL DSP Over Input RF UL Path Related Alarms Low Battery DL Out-Band Overload UL Over Input Over Temperature DSP Communication Battery Not Charge DL Input Overload UL Over Power Battery Not Connected DL DSP Over Input UL Return Power Door Open Over Current DL Over Input UL PLL Fail System Halt DL Over Power DL Return Power DL PLL Fail LED Indicator Solid Green Solid Yellow Solid Red 2.2 Specifications Normal operation Soft Fail alarm exists in the system Hard Fail alarm exists in the system Host / Remote Switch The Host/Remote Switch allows the user to switch the default Repeater IP, Subnet Mask, and Gateway of the Ethernet port of the repeater to an alternative setup. These settings can only be adjusted by logging into the repeater under HOST mode and configuring the settings under the Modem Box Setting section on the Install Page (section 5.4.6). Once the settings are set, flipping the switch to the REMOTE position will reboot the repeater with the new alternate settings. Please note that when the repeater is set to the REMOTE position, DHCP is disabled and the repeater will not automatically assign an IP address to any device that connects directly to the repeater. Host IP: 192.168.63.1 (Fixed IP, unable to modify this IP address) Remote IP: 192.168.63.5 (Default IP, but can be modified in Host mode) Figure 2-2 Advanced RF Technologies, Inc. Host/Remote Switch 17 2.3 Cable Connection 2.3.1 AC Power AC power is accepted through a standard 3-wire male plug (MS3106A-22-2S) with phase, neutral, and ground leads. The AC power is wired to a high-efficiency DC switching power supply which is UL approved. The AC port is located at the bottom of the repeater and has a free range input of 100-240V AC. Figure 2-3 AC Input Port AC On/Off switch Figure 2-4 AC On/Off Switch The AC Power on/off switch is on the left-hand side of the PSU which is located inside of the repeater. Advanced RF Technologies, Inc. 18 2.3.2 External Alarm Figure 2-5 External Alarm port This port should be connected only to the fire alarm control panel. Table 2-2 External Alarm Port Pin Description ADRF External Alarm Box Pin description Pin Pin Description (24 pins) Donor antenna malfunction_P 1-POS Output Donor antenna malfunction_N 1-NEG Output Active RF device malfunction_P 2-POS Output Active RF device malfunction_N 2-NEG Output Low battery capacity (70%)_P 3-POS Output Low battery capacity (70%)_N 3-NEG Output System component malfunction_P 4-POS Output System component malfunction_N 4-NEG Output Normal AC Power_P 5-POS Output Normal AC Power_N 5-NEG Output Loss of normal AC Power_P 6-POS Output Loss of normal AC Power_N 6-NEG Output Battery charger failure_P 7-POS Output Battery charger failure_N 7-NEG Output Low battery capacity (70%)_P 8-POS Output Low battery capacity (70%)_N 8-NEG Output Donor antenna malfunction_P 9-POS Output Donor antenna malfunction_N 9-NEG Output Active RF emitting device malfunction_P 10-POS Output Active RF emitting device malfunction_N 10-NEG Output System component malfunction_P 11-POS Output System component malfunction_N 11-NEG Output Alarm Input-1 Input GND GND Advanced RF Technologies, Inc. 19 Alarm Type 2.3.3 RF Figure 2-6 RF ports The RF connections are made via two 4.3-10 female connectors. The RF connector labeled “DONOR” must be connected to the antenna pointing towards the base station. The DONOR port can receive both 700 and 800MHz public safety signals. The RF connection labeled “SERVER” must be connected to the antenna facing the area to be covered by the BDA. The repeater has a single SERVER port that supports both 700 and 800MHz public safety signals. The RF connections must be made using cables with an impedance of 50 ohms. The separation between the antennas is necessary to prevent oscillation. Oscillation occurs when the signal entering the system continually re-enters, due to the lack of separation between the donor and server antennas. In other words, the signal is being fed back into the system. This creates a constant amplification of the same signal. As a result, the noise level rises above the signal level. To prevent feedback, the donor and server antennas must be separated by an appropriate distance to provide sufficient isolation. Isolation is attained by separating antennas a sufficient distance so that the output of one antenna does not reach the input of the other. This distance is dependent on the gain of the repeater. DONOR – 4.3-10 female which is used to connect the donor antenna (700MHz + 800MHz PS) DONOR_CPL (30dB) – SMA female 30 dB coupling port which is used to monitor the amplified UL signal SERVER_CPL (30dB) – SMA female 30 dB coupling port which is used to monitor the amplified DL signal SERVER – 4.3-10 female which is used to connect the server antenna (700MHz + 800MHz PS) Advanced RF Technologies, Inc. 20 2.3.4 Back Up Battery Port This port connects to the ADRF-BBS/BBL-24 (24V battery backup unit) via a dedicated cable provided by the ADRF. Figure 2-7 Battery Backup Port If an ADRF-BBS/BBL-24 is connected to the repeater, the battery switch on the PSU must be switched to the ON position. This will enable the repeater to charge the ADRF-BBS/BBL-24 battery backup unit when AC power is present. Figure 2-8 Battery Switch The PSR-78-9533 can be connected to an ADRF-BBS/BBL-24 to provide power during a power failure. If an ADRFBBS/BBL-24 is utilized, connect it to the PSR-78-9533 via the external battery port. (WARNING: The circuit breaker switch on the ADRF-BBS/BBL-24 must be set to OFF before connecting it to the PSR-78-9533 to prevent damage to the repeater or the ADRF-BBS/BBL-24 and personal injury.) Note: Please contact ADRF Technical Support for assistance if you are unfamiliar with the installation procedure of the battery box. Advanced RF Technologies, Inc. 21 2.3.5 Grounding A ground cable is included in the box. The grounding terminal is located at the lower right-hand side of the BDA. The grounding cable should be properly connected before powering on the equipment. Figure 2-9 Ground Cable Terminal Ground terminals located on the side of the repeater and can support a ground cable up to 1.25mm² (16AWG) in diameter and should be permanently connected to a grounding bar. 2.3.6 Ethernet Port The GUI port can be used to communicate directly with the PSR-78-9533 using an RJ-45 crossover cable. The weatherproof cap must first be unscrewed to gain access to the GUI port. Figure 2-10 Ethernet Port Advanced RF Technologies, Inc. 22 3. 3.1 ALARMS Message Board Alarms and Notifications Table 3-1 Message Board Alarms and Notifications Parameters AC Fail DC Fail Temperature Current System Halt DSP Fault OSC DL Signal not detected DL Signal Low Input Overload Out of band Overload Synthesizer Lock Fail DL RF Power Overpower VSWR Heartbeat Reboot Factory setting Door 3.2 Remark AC Input is outside of operating range DC Output is outside of operating range Module is above/below the normal operating temperature PSU is providing more than the max current System is in a shutdown state due to a hard fail alarm System has detected an issue with the internal DSP Oscillation detected DL signal is below the specified level DL signal is below the specified level Incoming in-band DL or UL signal is too strong Incoming out-band DL or UL signal is too strong Issue with internal PLL Input + gain does not match the output level (above delta of 6 dB) Output level is above the max output levels Power is being reflected back to the repeater Heartbeat is sent out to the NOC Soft reboot performed Factory default settings restored Door alarm set/clear Alarms Table 3-2 Alarms Parameters AC Fail DC Fail Temperature Remark Power supply is not operating within specs. (4 seconds) Power supply is not operating within specs. (4 seconds) Module is above the normal operating temperature. (4 seconds) Over Temperature [Soft: 80~87 C, Hard: Above 87 C] Current Power supply is not operating within specs. (4 seconds) Over Current [Hard: Above 20A] System Halt System is in a shutdown state due to a hard fail alarm. (10 cycles) DSP Fault System has detected an issue with the internal DSP chip. (Cannot communicate with DSP) OSC Oscillation detected. DL Signal not Detected DL signal is below the specified level. (default: -90dBm, 4 seconds) DL Signal Low DL signal is below the specified level. (default: -85dBm, 4 seconds) Input Overload Input signal is above the threshold. (4 seconds) (Soft: DL -5dBm/UL -5dBm, Hard: DL +5dBm/UL +5dBm) Out of Band Overload Out of band signal is above the threshold. (4 seconds) (Soft: DL -5dBm/UL -5dBm, Hard: DL +5dBm/UL +5dBm) Synthesizer Lock Fail Issue with internal PLL. (4 seconds) Advanced RF Technologies, Inc. 23 3.3 DL RF Power Input + gain does not match the output level. (default delta of 6 dB) Overpower Output level is above the max output levels. AGC On case (Soft: AGC Level + 1~2dB, Hard: AGC Level + >2dB) AGC Off case (Soft: max output level + 1~2dB, Hard: max output level + >2dB) VSWR Power is being reflected back to the repeater. Threshold = output power - 8dB. For example, if the repeater is outputting 24dBm and detects 16dBm of return power, then the VSWR will be triggered. (Alarm will only trigger when output power is 15dBm or greater) Door Door alarm set: Door open Door alarm clear: Door close External Alarms The PSR-78-9533 supports dry contact alarms and can be connected to a fire alarm control panel. The user can program the repeater to either create an open or closed circuit when an alarm is present in the system. 3.3.1 External Alarm Output interface 24V dc Simplex Digital Board ADRF Digital Board ADRF PSR Repeater Simplex Alarm Box External Alarm Name Donor Antenna Malfunction Active RF Device Malfunction Fire Alarm Low Battery Capacity (70% depleted) System Component Malfunction Normal AC Power Loss of Normal AC Power System Monitoring Battery Charger Failure Low Battery Capacity (70% depleted) Donor Antenna Malfunction Active RF Emitting Device Malfunction Advanced RF Technologies, Inc. Set Condition UL Return Power Hard Fail or No DL Signal Detected DL Return Power Hard Fail DL/UL Over Power Hard Fail DL/UL Input Overload Hard Fail Low Battery Soft Fail Over Current Hard Fail Over Temperature Hard Fail DSP Hard Fail Out-band Overload Hard Fail AC Normal Set AC Fail Soft Clear AC Fail Soft Set AC Normal Clear Battery Fail Soft Fail Battery Not Connected Soft fail Battery Not Charge Soft Fail Low Battery Soft Fail UL Return Power Hard Fail RF Power Soft Fail 24 External Alarm Name System Component Malfunction Set Condition DL Return Power Hard Fail DL/UL Over Power Hard Fail DL/UL Input Overload Hard Fail Over Current Hard Fail Over Temperature Hard Fail DSP Hard Fail Out-band Overload Hard Fail 3.3.2 External Alarm Input interface User Alarm Input Port No External Alarm In User Alarm ALARM IN 1 TBD Advanced RF Technologies, Inc. 25 Remark 4. 4.1 INSTALLATION Installation Procedures 4.1.1 Wall Mount Procedure • • • • • • • • Verify that the PSR-78-9533 and mounting hole are in good condition Place the PSR-78-9533 mounting bracket template up against the wall and mark off mount holes Drill the appropriate size holes and install the included wall anchors Remove the wall mount bracket from the repeater and bolt the wall mount bracket to the wall Place the repeater onto the wall mount bracket and secure the bracket to the repeater Connect the GND cable Connect the Antenna cable Connect the Power cable Wall Mount Bracket Figure 4-1 Advanced RF Technologies, Inc. Wall Mount 26 Antenna Separation/Isolation The separation between the donor and server antennas is necessary to prevent oscillation. Oscillation occurs when the signal entering the system continually re-enters, due to the lack of separation between the donor and server antennas. In other words, the signal is being fed back into the system. This creates a constant amplification of the same signal. As a result, the noise level rises above the signal level. PSR-78-9533 4.2 Figure 4-2 RF Repeater Oscillation To prevent feedback, the donor and server antennas must be separated by an appropriate distance to provide sufficient isolation. Isolation can be attained by separating antennas at a sufficient distance so that the output of one antenna does not reach the input of the other. This distance is dependent on the gain of the repeater. Recommended isolation value is 15dB greater than the user-set gain of the repeater. For example, if the userset gain of the repeater is 50dB, then an isolation of 65dB or greater is required. In the same manner, to utilize the maximum gain of 95dB of the PSR-78-9533, an isolation of at least 110dB is required. Advanced RF Technologies, Inc. 27 DO NOT APPLY A.C. POWER TO THE BDA UNTIL CABLES ARE CONNECTED TO BOTH PORTS OF THE BDA AND THE ANTENNAS. 1. To mount on a wall. Using appropriate screws and anchors and attach the BDA to the wall at the four mounting holes. 2. Ensure that the isolation between the donor antenna and the serving antennas is at least 15 dB greater than the BDA gain. 3. Connect the cable from the donor antenna to the BDA connector labeled “DONOR” and the cable from the serving antennas to the BDA connector labeled “SERVER”. 4. Connect the AC power cord to the BDA and turn on the switch at the left of PSU. 5. Installation of the BDA is now complete. Adjust the gain controls to suit the specific signal environment through the GUI on your PC. To prevent feedback, the donor and server antennas must be separated by an appropriate distance to provide sufficient isolation. Isolation is attained by separating antennas a sufficient distance so that the output of one antenna does not reach the input of the other. This distance is dependent on the gain of the repeater. Prior to equipment use, the device must be registered with the FCC. This can be done through the FCC’s website at https://signalboosters.fcc.gov/signal-boosters Advanced RF Technologies, Inc. 28 5. PSR-78-9533 WEB-GUI SETUP The Web-GUI allows the user to communicate with the repeater either locally or remotely. To connect to the repeater locally, you will need a laptop with an Ethernet port and an RJ-45 crossover cable. To connect to the repeater remotely, you will need to have an active internet connection via an external modem or LAN. 5.1 Repeater/PC Connection Using Web-GUI Verify that your Local Area Network Connection is set to obtain an IP address automatically under the Internet Protocol (TCP/IP) properties. If you are connecting to the unit remotely (use of a modem), then skip step above. Connect the RJ-45 crossover cable between the laptop’s Ethernet port and the repeater’s Ethernet port. Launch an Internet Browser. Type the following IP address into the address bar of the Internet Browser: http://192.168.63.1 If you are connecting to the unit remotely, then type the IP address of the modem to connect to the unit The following login screen will appear: Figure 5-1 Login Page If you are not the Administrator, please type in your assigned username & password which you should have received from the Administrator. The default username and password for the General User is adrf & adrf, respectively. The default Administrator login is admin & admin, respectively. Advanced RF Technologies, Inc. 29 5.2 Status Tab Figure 5-2 Advanced RF Technologies, Inc. Status Tab 30 5.2.1 Band Info The Band Info section displays frequency information along with the corresponding bandwidths that have been set from the Install tab. Input levels for each channel are also displayed in this section. Figure 5-3 Band Info Display 5.2.2 Power & Gain This section displays the Input, Gain, and Output for both downlink and uplink. Figure 5-4 Power & Gain Display Input [dBm] – Displays the in-band Downlink/Uplink signal level. The system will display “--.-“ when the input level is < -90 dBm. Outband [dBm] – Displays the out-band composite power. Gain [dB] User Set: Displays the amount of gain that the user set. Actual: Displays the actual amount of gain that is currently in use. Output [dB] – Displays the Downlink/Uplink composite output power levels. The system will display “--.-“, when the output level is < +5 dBm. Advanced RF Technologies, Inc. 31 5.2.3 Alarms This section displays the alarm status for System alarms, RF Alarms, and Power alarms. If an alarm is present in the system, then the color of the alarm tab will change according to the type of failure. Figure 5-5 Alarm Display 5.2.4 Repeater Info / Repeater Location / Technical Support / Installer Contact Info Figure 5-6 Repeater Info / Repeater Location / Technical Support / Installer Contact Info Repeater Info: Displays the serial number, latitude, longitude, firmware version, and Web-GUI version Repeater Location: Displays the address where the repeater is installed Technical Support: Displays ADRF’s Technical Support contact information Installer Contact Info: Displays the installer’s name, phone, and e-mail address Note: Once successfully logged in, the repeater model name and the site/cascade ID will be displayed on the top of all the windows (except for the Main Window). Advanced RF Technologies, Inc. 32 5.3 Control Tab Figure 5-7 Advanced RF Technologies, Inc. Control page 33 5.3.1 General Setting The General Setting section allows the user to enable/disable amplifiers and the ALC routine. Figure 5-8 General Setting ALC ON: Enables or disables Automatic Level Control (ALC) PSR 700 DL HPA On: Enables or disables the Downlink High Power Amplifier (HPA) for 700MHz PS PSR 800 DL HPA On: Enables or disables the Downlink High Power Amplifier (HPA) for 800MHz PS PSR 700+800 UL HPA On: Enables or disables the Uplink High Power Amplifier (HPA) for 700+800MHz PS To enable/disable any of the settings, click on the checkbox and click the Apply button. 5.3.2 System Under the System section, the user is able to perform soft reboot on the repeater and also can restore factory default settings. Figure 5-9 System Reboot: Performs a soft reboot of the repeater Factory Set: Restores all settings to factory defaults 5.3.3 Manual Gain Control Figure 5-10 Manual Gain Control Setting DL/UL Gain: Gain levels of the repeater can be specified here DL/UL ALC Level: Prevents the output power from exceeding the specified value DL/UL Output ALC Offset: If any ALC attenuation has been applied, the system will release this attenuation when the signal level drops by the specified level DL /UL Gain Balance ON: Allows the user to enable or disable the gain balance. When gain balance is enabled, the delta value between the downlink and uplink gains remain constant Advanced RF Technologies, Inc. 34 5.3.4 Alarm Settings Figure 5-11 Alarm Settings DL Signal Low Level: Allows the user to specify how low the signal can be before triggering a “Downlink Signal Low” soft-fail alarm DL Signal Not Detected Level: Allows the user to specify how low the signal can be before triggering a “Downlink Signal Not Detected” soft-fail alarm DL RF Power Level: Allows the user to set a maximum deviation value for the downlink RF power before triggering a “DL RF Power Level” soft-fail alarm For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power should be 10 dBm. If the Downlink RF Power alarm value is set to 6dB, then a soft-fail alarm will trigger if the output power falls below 4 dBm DL Over Power Level: DL Over Power Alarm will trigger when the DL output level exceeds this level UL Over Power Level: UL Over Power Alarm will trigger when the UL output level exceeds this level Battery Check: • Check All – All battery related alarms are checked which include Battery Fail, Battery Not Installed, Low Battery, and Battery Not Charge • Except Install – Only Battery Fail, Low Battery, and Battery Not Charge alarms are checked • Check Off – Does not perform any battery check Battery Not Charge Check: • On – Checks for the Battery Not Charge alarm • Off – Disables the check for the Battery Not Charge alarm Advanced RF Technologies, Inc. 35 5.4 Install Tab 5.4.1 Install Figure 5-12 Install Page Advanced RF Technologies, Inc. 36 5.4.2 Technology This section allows the user to set the repeater mode to either use PS700, PS800, or PS700+PS800. Figure 5-13 Technology The following choices are available from the dropdown: • PS700 (758-775MHz) • PS800 (851-861MHz) • PS700+PS800 (758-861MHz) 5.4.3 Band Selection Figure 5-14 Band Selection Band selection allows the user specify the desired frequncies by inputting the center frequencies and selecting the bandwidths. Reference Center Frequency: The user can input the center frequency of the pass-band. Bandwidth: Allows the user to select the desired bandwidth for the passband. Choices for wide band frequencies include 5 and 10MHz. Narrow band choices include 6.25, 12.5, 25.0, and 200 KHz. Downlink/Uplink Gain: Minor gain adjustments can be performed on a per channel basis to equalize signal levels Downlink Freq - Start: Displays the start frequency of the pass-band once the band selection has been set Downlink Freq - End: Displays the end frequency of the pass-band once the band selection has been set Advanced RF Technologies, Inc. 37 5.4.4 SNMP Figure 5-15 SNMP The SNMP section allows you to specify the Site ID and Description. The Site-ID is the code that is used to identify the repeater. 5.4.5 Location This section allows the user to input the latitude and the longitude of the repeater. Figure 5-16 Location Setting 5.4.6 Modem Box Setting This section allows the user to specify alternative Repeater IP, Subnet Mask, and Gateway settings. These settings are enabled when the Host/Remote switch is set to the Remote position. Figure 5-17 Modem Box Setting 5.4.7 AAI Input The PSR-VU-9537 can accept a dry contact input alarms. The alarm can be labeled in this section. Once the alarm is labeled, it will show up in the system with the new custom names on the Status tab. Figure 5-18 AAI Input Advanced RF Technologies, Inc. 38 5.4.8 Location Info / Installer Info This section allows the user to specify the address of the repeater and also the information of the installer. Figure 5-19 Repeater Location Info / Repeater Installer Info 5.4.9 Date & Time This section allows the user to specify the current date and time. Figure 5-20 Date & Time Setting Advanced RF Technologies, Inc. 39 5.5 System The System tab allows the user to perform firmware updates, upload closeout packages, view any changes to the system, backup existing configuration, and add/remove user accounts, and change the login credentials of the Administrator. 5.5.1 System: Account 5.5.1.1 System: Account – Account Management The Account Management section allows the Administrator to delete any user accounts. Please note that the Account Management section is only available if you are logged into the system as the Administrator. To delete a user account click on the Account Management link and under the Delete column, click on the delete button. Figure 5-21 System: Account- Account Management 5.5.1.2 System: Account – New Account The New account section allows the Administrator to create a new user account. Please note that the New account section is only available if you are logged into the system as the Administrator. To create a new user account click on the new account link and fill in the fields shown. Figure 5-22 System: Account- New Account 5.5.1.3 System: Account – Change Password The Change Password section allows the current user who is logged into the system to change their login credentials. Figure 5-23 System: Account- Change Password 5.5.2 System – User Log Advanced RF Technologies, Inc. 40 This section displays system events that have taken place. The User Log displays who has made the changes, the time and date of when the event took place, and what changes were made to the system. Figure 5-24 System – User Log Advanced RF Technologies, Inc. 41 5.5.3 System – Update To perform a firmware update, click on the Update tab and the following screen will appear. Figure 5-25 System – Update Click on the Choose File button and locate the firmware file. Click on the Upgrade button to perform the firmware update. Once the firmware update is complete, the following popup message will appear: Figure 5-26 Pop-up Message after System Update is Complete 5.5.4 System – Backup & Restore The backup section allows the user to save the settings of the repeater. To perform the backup, click on the Backup button and you will be prompted to save the backup file. To restore the settings to the system, click on Choose File button, select the backup file, and click the Restore button. Figure 5-27 System Backup Advanced RF Technologies, Inc. 42 5.6 Help If an internet connection is available, clicking on the Help Tab will redirect the user to our Technical Support page. Figure 5-28 Help 5.7 Logout Clicking the Logout button will log the current user off the system. 6. MAINTENANCE GUIDE FOR PSR-78-9533 REPEATER 6.1 Periodic Inspection Checklist Check for loose connections between the repeater and antennas. If connections are loose, make sure that all connections are tightly fastened properly. Cables and connectors are in good condition. Ensure that the repeater brackets are in good condition and that the repeater is securely fastened. 6.2 Preventive Measures for Optimal Operation 6.2.1 Recommendations Perform the Periodic Inspection Checklist quarterly or semi-annually. 6.2.2 Precautions Do not operate the repeater with the antennas in extremely close proximity to one another as this may cause damage to the repeater. Do not change the parameters unless instructed to do so by an authorized supervisor. Do not move the repeater unless instructed to do so by an authorized supervisor. Do not detach any cables to the repeater unless repair of respective components is necessary. Advanced RF Technologies, Inc. 43 7. 7.1 WARRANTY AND REPAIR POLICY General Warranty The PSR-78-9533 carries a Standard Warranty period of two (2) years unless indicated otherwise on the package or in the acknowledgment of the purchase order. 7.2 Limitations of Warranty Your exclusive remedy for any defective product is limited to the repair or replacement of the defective product. Advanced RF Technologies, Inc. may elect which remedy or combination of remedies to provide in its sole discretion. Advanced RF Technologies, Inc. shall have a reasonable time after determining that a defective product exists to repair or replace the problem unit. Advanced RF Technologies, Inc. warranty applies to repaired or replaced products for the balance of the applicable period of the original warranty or ninety days from the date of shipment of a repaired or replaced product, whichever is longer. 7.3 Limitation of Damages The liability for any defective product shall in no event exceed the purchase price for the defective product. 7.4 No Consequential Damages Advanced RF Technologies, Inc. has no liability for general, consequential, incidental or special damages. 7.5 Additional Limitation on Warranty Advanced RF Technologies, Inc. standard warranty does not cover products which have been received improperly packaged, altered, or physically damaged. For example, broken warranty seal, labels exhibiting tampering, physically abused enclosure, broken pins on connectors, any modifications made without Advanced RF Technologies, Inc. authorization, will void all warranty. 7.6 Return Material Authorization (RMA) No product may be returned directly to Advanced RF Technologies, Inc. without first getting an approval from Advanced RF Technologies, Inc. If it is determined that the product may be defective, you will be given an RMA number and instructions on how to return the product. An unauthorized return, i.e., one for which an RMA number has not been issued, will be returned to you at your expense. Authorized returns are to be shipped to the address on the RMA in an approved shipping container. You will be given our courier information. It is suggested that the original box and packaging materials should be kept if an occasion arises where a defective product needs to be shipped back to Advanced RF Technologies, Inc. To request an RMA, please call (800) 3139345 or send an email to techsupport@adrftech.com. Advanced RF Technologies, Inc. 44 8. SPECIFICATIONS 8.1 Electrical Specifications Table 8-1 Electrical Specifications Specifications Parameters Remarks DL UL FirstNet + PS 700 758 ~ 768 MHz (for FCC) 769 - 775MHz(For FCC) (768-769MHzGuard band) 768 – 775 MHz (For ISED) 788 ~ 798 MHz (for FCC) 799 - 805 MHz(For FCC) (798- 799MHz Guard band) 798 - 805 MHz (For ISED) PS 800 851 - 861 806 - 816 FirstNet / PS 700 / FirstNet + PS 700 33 dBm 30 dBm PS 800 33 dBm 30 dBm FirstNet + PS 700 + PS 800 36 dBm (33dBm + 33dBm) 30 dBm System Gain (dB) 95 95 Filter selection Broad / Narrow / Broad + Narrow band Frequency Range (MHz) Composite Power Output Simultaneous Filter Support numbers Filter Bandwidth Filter Roll-off Broad Band Narrow Band 2 (non-contiguous) @ FirstNet / PS 700 / PS 800 / FirstNet + PS 700 / FirstNet + PS 700 + PS 800 Up to 16 (Non-contiguous) @ PS 700 / PS 800 Up to 32 (Non-contiguous) @ PS 700 + PS 800 Broad (MHz) 5, 10MHz Narrow (KHz) 75 ~331.25 (6.25 x n , n= 12~53) Broad (MHz) 60dBc@Filter Bandwidth Edge + 1MHz Narrow (KHz) FCC Rule Compliant Passband Ripple ±2 dB ALC Dynamic Range ≥ 60dB Gain Dynamic Range ≥ 45dB Channel Setting Resolution 0.025 kHz Noise Figure @ Max. gain ≤5dB Broad Band <6us Narrow Band <126us@6.25KHz BW, <67us@12.5KHz BW, <36us@25KHz BW, <10us@200KHz BW Power Supply 100 -240 VAC, 60 Hz (Free Voltage) Power Consumption <150 W Max RF Input Power without over drive -20dBm No damage Max Input Power +10 dBm Impedance 50 Ω VSWR <1.3 : 1 Dry Contacts NFPA 1221 2016 Code Compliant Remote Alarming / Network Management Dry Contacts, Web-GUI, SNMP, SNMP-Traps (External Wireless Modem Required) Advanced RF Technologies, Inc. APCO 25 APCO 25 Extra filter upload available by custom request. 55dBc @Filter Bandwidth Edge + 3 * Filter BW Spurious System Group Delay LTE (5 MHz) 45 Optional battery backup Humidity 5% - 90% RH Condensed Operating at Ambient Temperature -40°F to +140°F (-40°C to +60°C) 8.2 Mechanical Specifications Table 8-2 Parameters Mechanical Specifications Specifications Comments Dimensions W x D x H 11.0 x 9.0 x 21.67 in (w/o mounting bracket) Weight 55 lbs (w/o mounting bracket) RF Connector 4.3-10 (Female) Weather Resistances IP66 8.3 Power Specifications Table 8-3 Parameters AC Power AC Supply Protection Power Specifications Specifications Comments 100 -240 VAC, 60 Hz (Free Voltage) Fuse & Circuit Protector T6.3L250V Battery Backup Power Consumption AC 150W (120V/1.25A), DC 24V/6.25A Ground External Threaded Stud 8.4 Warranty & Certificates Table 8-4 Parameters MTBF Warranty & Certificates Specifications Comments > 100,000 Hours Ambient UL60950 Compliance FCC CFR47 part 15 FCC CFR47 part 90 Warranty 2 Years Advanced RF Technologies, Inc. 46 9. MECHANICAL DRAWING Figure 9-1 Advanced RF Technologies, Inc. PSR-78-9533 Mechanical Drawing 47 10. APPENDIX 10.1 Shutdown Retry Logic The function of the built-in shutdown routine is to protect the repeater from any further damage from a hardfail that the system may be experiencing. Within 5 seconds of a hard-fail alarm being detected, the repeater will start the shutdown routine. The repeater will shut down by powering of the HPAs (high-powered amplifiers) for 30 seconds. After 30 seconds have elapsed, the repeater will power on the HPAs and check to see if the hard-fail alarm still exists. If the hard-fail alarm still exists, then the repeater will shut down for 1 minute (double the time of the previous shutdown time). After 1 minute has elapsed, the repeater will power on the HPAs and check to see if the hard-fail alarm still exists. If the hard-fail alarm still exists, then the repeater will shut down for 2 minutes (double the time of the previous shutdown time). The shutdown routine will repeat itself a total of 10 times. If the hard-fail alarm still exists after the 10th retry, then the repeater will turn off its HPAs permanently until a reset is performed or factory set is executed. Advanced RF Technologies, Inc. 48
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : ADRF Tech Company : ADRF Tech Create Date : 2017:05:26 16:32:05+09:00 Modify Date : 2017:05:26 16:32:28+09:00 Source Modified : D:20170526073132 Version : 0.1 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08 Metadata Date : 2017:05:26 16:32:28+09:00 Creator Tool : Word용 Acrobat PDFMaker 11 Document ID : uuid:0b62c3fd-fbcf-4bfa-864f-c815695bc335 Instance ID : uuid:ca6af074-0821-4ca4-9db8-7723b6e2b243 Subject : 6 Format : application/pdf Title : AXMS8C-9543-ICS-X MANUAL Creator : ADRF Tech Producer : Adobe PDF Library 11.0 Page Layout : OneColumn Page Count : 48EXIF Metadata provided by EXIF.tools