RFbeam Microwave GmbH © RFbeam Microwave GmbH www.rfbeam.ch Page 1/5Introduction This document describes the AGD-T7813 modules Issue ‚1’. This module has the following features: Improved Ceramics Material (Temex E2036)RF-Transistor with higher gainAdjusted PCB Layout with tighter coupling for Resonator (lower loss)Electrical Specification Parameter Conditions / Notes Symbol Min Typ Max Unit Operating conditions Supply voltage Vcc 3.15 3.3 6.0 V Supply current Module enabled Icc140 60 80 mA RF-Part disabled Icc2 5 10 mA VCO input voltage Uvco 0 5.5 V VCO pin resistance Internal pulldown 100kRvco 100k  Operating temperature Top -20 +70 °C Storage temperature Tst -40 +85 °C Power down/Enable RF power down Input tied high with pullup 100k VIH1 2.7 Vcc+ 0.3 V RF enable VIL1 -0.2 0.7 V Minimum enable time RF-part fully functional ton 5 s Maximum hold time LP capacitor charge error < 10% toff 2 ms Transmitter Transmitter frequency UVCO= 3.0V, Tamb= 25°C fTX 24.120 24.125 24.130 GHz Frequency drift vs temp. Vcc=3.3V, -20°C .. +70°C fTX -0.27 MHz/°C Frequency tuning range (VCO) UVCO= 1V .. 5V  fvco 35 50 70 MHz VCO sensitivity Svco 12.5 MHz/V VCO Modulation Bandwidth f=1MHz BVCO 200 kHz Output power EIRP PTX +13 +16 +20 dBm Output power deviation Full VCO tuning range  PTX +/- 2 dBm Spurious emission According to ETSI 300 440 Pspur -30 dBm Receiver Antenna gain FTX=24.125GHzGAnt15 dBiLNA gain FRX=24.125GHzGLNA 9 dBMixer Conversion loss fIF =500Hz Dmixer-2.0 dBReceiver sensitivity fIF =500Hz, B=1kHz, S/N=6dB PRX -114 dBm Overall sensitivity fIF =500Hz, B=1kHz, S/N=6dB Dsystem-130 dBc Datasheet AGD-T7813-125  Issue ‘1’ MC-133
RFbeam Microwave GmbH Datasheet AGD-T7813-125  Issue ‘1’ MC-133© RFbeam Microwave GmbH www.rfbeam.ch Page 2/5Parameter Conditions / Notes Symbol Min Typ Max Unit IF output IF output impedance RIF 100  IF Amplifier gain GIF 30 dB I/Q amplitude balance fIF =500Hz, UIF=100mVpp UIF 3 dB I/Q phase shift fIF =500Hz, UIF=100mVpp  70 90 110 ° IF frequency range -3dB Bandwidth fIF_AC 20 500k Hz IF noise voltage fIF =500Hz UIFnoise 1.0 3.2 7.9 V/Hz fIF =500Hz UIFnoise -120 -110 -102 dBV/Hz IF output offset voltage Vcc = 3.3V Uos_AC 1.0 1.5 2.0 V Supply rejection Rejection supply pins to IF outputs, 1kHz Dsupply 26 dB Antenna Horizontal -3dB beamwidth E-Plane W 28 30 32 ° Vertical -3dB beamwidth H-Plane W 28 30 32 ° Horiz. sidelobe suppression D -20 -25 dB Vert. sidelobe suppression D -16 -20 dB Body Outline Dimensions connector left unconnected 35*65*17 mm3 Weight 62 g Connector 8 pins Antenna Pattern Typical Antenna Pattern for one antenna (RX- or TX-side). Measured at 24.200GHz:
RFbeam Microwave GmbH © RFbeam Microwave GmbH www.rfbeam.ch Page 3/5Block diagram Frequency vs. VCO-Voltage and Temperature Pin 8 voltage vs. Temperature Datasheet AGD-T7813-125  Issue ‘1’ MC-133
RFbeam Microwave GmbH © RFbeam Microwave GmbH www.rfbeam.ch Page 4/5Connector Pinout On module side a Samtec HW-04-15-F-D-325-SM connector with the following pinout is used: 1:  /Enable   Enable/Disable RF-part. Connect to 0V for normal operation 2:  +3.3V  Power Supply. Connect to +3.3V (3.15V .. 6.0V) 3:  GND  Ground connection. Connect to 0V 4:  Q Out  Analog Output Q-Channel 5:  I Out  Analog Output I-Channel 6:  VCO  Frequency control input. A voltage between 1..5V adjusts TX Frequency by 0 .. 50MHz. Can be used for FSK or FMCW 7: S&H  Sample&Hold Switch Analog Output. Leave it open or connect to +3.3V for normal operation 8:  Temp  Temperature Sensor output of LMT84 temperature sensor Mechanical Drawing FCC Labelling Information: (label to be placed into the recess position * shown in the mechanical drawing above FCC ID: WH3 -MC-133 AGD-T7813-125 (MC-133)Frequency 24.125GHzIssue 1Serial No:   in barcode or datamatrix format *Datasheet AGD-T7813-125  Issue ‘1’ MC-133
Document History Author: Date:  Léon Audergon, RFbeam Microwave GmbH, CH-9008 St. Gallen August 25th 2015Version: Changes:  1.1 I- and Q-outputs exchanged Different drawings added © RFbeam Microwave GmbH www.rfbeam.ch  Page 5/5This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance such that the module should not be installed in equipment intended to be used within 20cm of the body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.Changes or modifications not expressly approved by AGD SYSTEMS Ltd could void the user's authority to operate the equipmentFCC ApprovalManufacturers of mobile or fixed devices incorporating MC-133 modules are authorized to use the FCC Grants of the MC-133 modules for their own final products according to the conditions referenced in these documents. In this case, the FCC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID: WH3-3-MC-133".RFbeam Microwave GmbH Datasheet AGD-T7813-125  Issue ‘1’ MC-133

Navigation menu