ALE USA OAW-AP1101 Alcatel-Lucent Enterprise OmniAccess AP User Manual
ALE USA Inc. Alcatel-Lucent Enterprise OmniAccess AP Users Manual
ALE USA >
Users Manual
Alcate el-Lucent Ente erprise OAW-A AP Access Poin nt Installation Guide 060436-11 Rev. A *060436-11 Re ev. A* enterprise.a alcatel-lucent.com Alcatel-Luce ent and the Alcatel-Luce ent Enterprise logo are trademarks of Alcatel-Luce ent. To view other tradema arks used by affiliated com mpanies of ALE Holding, vvisit: enterprise.alcatel--lucent.com/trademarks. All other trademarks are the property of theiir respective owners. The e information presented is subject to ALE without no otice. Neither ALE Holding g nor any of its affiliates asssumes any responsibilityy for inaccuracies conta ained herein. (2016) Figure 2: OAW-AP Acccess Point (Front V View) Access points are e radio transmissio on devices and arre subject to governmental reg gulation. Networrk administrators who are resp ponsible for th he configuration and operation of access points musst comply with loca al broadcast regullations. Specifically, access point mustt use channel assig gnments appropriatte to the location wh here the access poiint will be deployed d. This doccument describes the packaging, A AP layout, general p process of installattion as well as wa arning and notices that need to be addressed prior to in nstallation. It’s recom mmend that the entire document be rea ad prior to installatio on. All new AP installations are typically performe ed in the following sequence: Unpa ack the AP and chec ck all items in the box WLA AN Planning. Usually y, a comprehensive ssite survey is re equired before insta allation. There are many facto ors to consider such h as coverage area, power supp ply to the AP, locatio on of AP brackets, etc. Insta all the AP bracket on o wall or ceiling. Insta all communications outlet (if new outle et is insta alled) label and testt. Insta all each AP to brack ket. Insta all patch cord into port on AP. Insta all patch cord into outlet. Veriffy post-installation connectivity. Conffigure each AP. For product ava ailable in the USA/ /Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. This de evice is restricted for indoor use. Pour les produitts disponibles aux É États-Unis / Canada a du marché, seul le e canal 1 à 11 peuvent être exploittés. Sélection d'autrres canaux n'est pa as possible. Pour une utilisation en intérieur uniquementt. Package Contentss Access Pointt Dimen nsions(HxWxD): 6.1 inches x 6.1 inches x 1.1 inc ches (15.5 cm x 15.5 cm x 2.8 cm) Weightt: 270g 9/16" Ceiling g Rail Adapter 15/16" Ceilin ng Rail Adapter Quick Start Guide Installation Guide User Guide Access Card Fiigure1: Product Paccking Inform your ALE sales representative e of incorrect, missing, or damag ged parts. If possib ble, retain the carton, including the original packiing materials. Use these materia als to repack and re eturn the unit to the supplier if needed. Additional mounting kits for use with the OAW- AP1101 acce ess points are sold separately.. Contact your ALE sales representative forr details. Device view The OAW-AP accesss point is equipped with one hidden LE ED light that indicate es different status with different color. Hidden LED Location the United State es configured to non n-US model controlllers will be in violattion of the FCC rule es. Any such willfull or intentional viola ation may result in a requirement by the FCC for immedia ate termination of operation and mayy be subject to forfeiiture (refer to 47 CF FR 1.80).EU Statement: Low power radio o LAN product operating in 2.4 GHz an nd 5 GHz bands. Plea ase refer to the ALE OS User Guide for details on restrictions. Dynamic Frequency Selection (DFS) for devices operatting in the bands 5250- 5350 MHz, 5470-5600 MHz a and 5650-5725 MHz. Sélection dynam mique de fréquen nces (DFS) pour les dispositifs foncttionnant dans les ba andes 5250-5350 MHz, 5470-5600 MHz et e 5650-5725 MHz. Securityy Lock Reset Conso ole Ethernet DC Power Sockket Figure 3: OAW-AP Access Point (Back V View) Item Name Specificationss Etherne et Port The OAW-AP P is equipped with one 10/100/1000B Base-T (RJ-45) auto-sensing, MDI/MDX wire ed-network connecttivity port. Console Port The console port is an RJ--45 female connector and d can be used to cconnect to a terminal for direct local managem ment. The OAW-AP has h a single 48V DC C power jack socket to su upport powering through an AC-to-DC pow wer adapter, If PoE is not available, an optional AC-DC adapter kit (sold separate ely) can be used to o power the OAW-AP. The OAW-AP is equipped with a ssecurity lock slot for additional security. DC Pow wer Socket Securityy Lock Slo ot Pre-insttallation FCC Sta atement: Improper installation of acce ess points in 註解 [l1]: Add FCC and IC C 2.4G warning statement The device for operation in the band 5150–5250 MHzz is only for indoor use to reduce the potential for harm mful interference to co-channel mobile satellite systems. les dispositifs fo onctionnant dans la bande 5150-5250 M MHz sont réservés un niquement pour une e. utilisation à l’intérieur afin de rréduire les risques de brouillage préjjudiciable aux sysstèmes de satelliites mobiles utilisant les mêmes canaux x. Users should alsso be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 0 MHz and 5650-585 50 MHz and that these radars could cause interference e and/or damage to LE-LAN devices. De plus, les utillisateurs devraient aussi être avisés q que les utilisateurs de radars de h haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ontt la priorité) pour les bandes 5250-53 350 MHz et 5650-58 850 MHz et que cess radars pourraientt causer du brouilla age et/ou des domm mages aux dispositifs fs LAN-EL. Pre-Installation Checklist Before installing g your OAW-AP acccess point, be sure that you have th he following items: 4- or 8-con nductor, CAT5 or better UTP cable of required length. One of the e following power so ources: IEEE 802.3af-compliant Power over Etherne et (P PoE) source (The PO OE source can be an ny 註解 [l2]: 5G DFS FCC and IC warning Statem ment power source equipment (PSE) controller or mid-span PSE device. 48 V/0.6A DC AP AC-DC adapter kit (sold separately) A terminal or a notebook Pushing toward the ceiling tile, rotate the AP clockwise until the device clicks into place on the ceiling tile rail(see Figure 5). Identifying Specific Installation Locations You can mount the OAW-AP on a ceiling rail (using the included adapter) or on a wall (using the wall mount adapter, sold separately). You should first determine the location of the installation. The installation position is located at the center of the required coverage area and should be free from obstructions or obvious sources of interference. Figure 4: Attaching Ceiling Rail Adapter RJ45_DB+ BI_DB+ TX+ PoE+ RJ45_DC+ BI_DC+ Spare PoE+ RJ45_DC– BI_DC- Spare PoE+ Red and Blue LEDs alternate flashing in specific frequency; OS upgrading 3 LEDs alternate flashing in specific Flash Flash Flash System running frequency; Used for locating an AP RJ45_DB– BI_DB- TX– PoE+ Table 2: OAW-AP LED Meaning RJ45_DD+ BI_DD+ Spare PoE- RJ45_DD– BI_DD- Spare PoE- Configuring the OAW-AP Refer to the Quick Start Guide and configuration guide for complete details. Table 1: Minimize the number of obstructions (such as walls) between the AP and user terminals. Electronic equipment or devices (such as microwave ovens) which may produce radio frequency noise should be away from the installation position of the AP. It is strictly prohibited to install around stagnant water, water seepage, leakage or condensation. Avoid cable condensation or water seepage along the cable connecting to the AP. Connect Power Sources Confirm that you have an IEEE 802.3af-compliant Power over Ethernet (PoE) source on the Ethernet cable, if not, connect by using the ALE 48V DC AP AC-DC adapter kit (sold separately) to the DC Power Socket and AC power jack. Temperature and Humidity requirement Operating temperature: 32ºF to 113ºF(0ºC to 45ºC ) Storage temperature: -40ºF to 158ºF(-40ºC to 70ºC) Relative Humidity: 5% to 90% non-condensing AP Installation Use Ceiling Rail Adapter If both POE and DC power are available, the use of DC is preferred. OAW-AP supports the power adapter provided by ALE ONLY. Figure 5: Mounting AP Connect Ethernet Use the Ethernet port to connect the AP with a twisted pair Ethernet LAN segment. Use a 4- or 8-conductor, Category 5 UTP cable. The port is an RJ-45 female connector with the pin-outs shown in Table 1. Make sure the AP fits securely on the ceiling tile rail when hanging the device from the ceiling, poor installation could cause it to fall onto people or equipment. The OAW-AP has been shipped with two ceiling rail adapters for 9/16” and 15/16” ceiling rails. Following is the general sequence to install the OAW-AP with the Ceiling Rail Adapter. Pull the cables through a prepared hole in the ceiling tile near where the AP will be placed. Place the adapter against the back of the AP, insert by aligning the slot on the backside with the hanging feet on both sides of the adapter (see Figure 4) . Push the adapter along the direction of the arrow until it locks in the slot (see Figure 4). Connect the cable to the port on the AP. Hold the AP next to the ceiling tile rail with the ceiling tile rail mounting slots at approximately a 20degree angle to the ceiling tile rail (see Figure 5). Make sure that any cable slack is above the ceiling tile. Ethernet Port Pin-out Verifying Post-Installation Connectivity The LED on the AP can be used at this point to verify that the AP is receiving power and initializing successfully (see Table 2). Time Red Blue Green Status Line ON Power on ON Bootloader-OS loading Flash Pin Signal Name GE FE PoE RJ45_DA+ BI_DA+ RX+ PoE- RJ45_DA– BI_DA- RX– PoE- Network abnormal (Interface down) Network normal, Flash System running without SSID created Network normal, single ON System running band working, either 2.4Ghz or 5Ghz Network normal, dual bands working, 2.4Ghz System running and 5Ghz are both working System running ON System start up Flash Flash System running Regulatory Compliance ALE USA Inc., hereby declares that this OAW-AP model is compliant with the essential requirements and other provisions of Directive 2014/53/EU. For the complete CE DoC, please access the website below to get more information: service.esd.alcatel-lucent.com Waste Electrical and Electronic Equipment (WEEE) Statement ALE products are subject to separate collection and treatment in the EU Member States, Norway, and Switzerland when they are at end of life, and therefore are marked with the symbol shown. The treatment applied to these products in these countries shall be compliant with the applicable national laws which are under the implementing of Directive 2012/19/EU on Waste of Electrical and Electronic Equipment (WEEE). European Union RoHS ALE products are compliant with the EU Restriction of Hazardous Substances Directive 2011/65/EU (RoHS). EU RoHS restricts the use of specific hazardous materials in the manufacture of electrical and electronic equipment. The restricted materials under the Directive are Lead (including Solder used in printed circuit assemblies), Cadmium, Mercury, equivalent Chromium, and Bromine. FCC Class B Part 15 and Industry Canada license-exempt RSS standard(s): This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This equipment has been tested and compliant with the limits for a Class B digital device under part 15 of the FCC Rules. This equipment generates,uses and can radiate radio frequency energy. If it is not installed and used in accordance with ALE’s instructions, it may cause harmful interference. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one or more of the following ways: Reorient or relocate the antenna. Increase the separation between the equipment and other devices. Connect the equipment to an outlet on a circuit different from that to which the other device is connected. Consult the dealer or an experienced radio technician for help. Complies with the Class B limits for radio noise emissions as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of Industry Canada. EU Regulatory Conformance ALE USA, Inc., hereby declares that this OAW-AP model is compliant with the essential requirements and other provisions of Directive 2014/53/EU. California Proposition 65 Warning WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. RF Radiation Exposure Statement: This equipment complies with FCC,IC and CE RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 20 cm between the equipment and a human’s body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. 註解 [l3]: Add Industry Canada statement 註解 [l4]: Repeated CE DoC, should be deleted 註解 [l5]: Add IC of Canada 註解 [l6]: Add French Warning of IC For Model OWA-AP1101, the frequency and the maximum transmitted power are listed below: 2412-2472MHz: 19.97dBm 5180-5240MHz: 22.70dBm 5260-5320MHz: 22.89dBm 5500-5700MHz: 28.27dBm 註解 [l7]: Add CE RED new requirement
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : ChristyFan Create Date : 2016:08:08 17:24:24+08:00 Modify Date : 2016:08:08 17:24:24+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : Microsoft Word - 8.1 OAW-AP Access Point Installation Guide_060436-11_revA_print ok Creator : ChristyFan Document ID : uuid:12380eee-e1e3-472e-b907-ea1b6133afb6 Instance ID : uuid:c214c1fa-7198-42d3-8ac8-1003ced57479 Page Count : 3EXIF Metadata provided by EXIF.tools