AMERICAN MEGATRENDS INDIA PRIVATE AMI-ECG-01 Chest ECG User Manual AMI BOLT

AMERICAN MEGATRENDS INDIA PRIVATE LIMITED Chest ECG AMI BOLT

Users Manual

Download: AMERICAN MEGATRENDS INDIA PRIVATE AMI-ECG-01 Chest ECG User Manual AMI BOLT
Mirror Download [FCC.gov]AMERICAN MEGATRENDS INDIA PRIVATE AMI-ECG-01 Chest ECG User Manual AMI BOLT
Document ID2780918
Application IDLrsD+7Ln022F8BAOYeIYtQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize78.07kB (975869 bits)
Date Submitted2015-10-14 00:00:00
Date Available2015-10-14 00:00:00
Creation Date2015-10-09 14:44:02
Producing SoftwareMicrosoft® Word 2013
Document Lastmod2015-10-09 14:44:02
Document TitleAMI BOLT
Document CreatorMicrosoft® Word 2013
Document Author: Balraj P

ONE-TOUCH WIRELESS HEALTH TRACKER
BODY LIFE TRACKER
AMI Chest ECG
User Manual
Model: VA07
Document No
: AMI-PRD-UM-B-VA07
Version
: 1.0
Date
: 24.08.2015
B.O.L.T User Manual
Model No: VA07
Legal
Disclaimer
This publication/content contains proprietary information which is protected by copyright. No
part of this publication may be reproduced, transcribed, stored in a retrieval system, translated
into any language or computer language, or transmitted in any form whatsoever without the prior
written consent of the publisher. American Megatrends India Private Ltd. retains the right to
update, change or modify this publication at any time, without notice.
For Additional Information
Call American Megatrends India Private Ltd at 1800-419-9868.
Limitations of Liability
In no event shall American Megatrends India Private Ltd be held liable for any loss, expenses, or
damage of any kind whatsoever, whether direct, indirect, incidental, or consequential, arising
from the design or use of this product or the support materials provided with the product.
Limited Warranty
No warranties are made, either expressed or implied, with regard to the contents of this work, its
merchantability, or fitness for a particular use. American Megatrends India Private Ltd assumes
no responsibility for errors and omissions or for the uses made of the material contained herein
or reader decisions based on such use.
Trademark and Copyright Acknowledgments
Copyright © 2015 American Megatrends India Private Ltd. All Rights Reserved.
AMERICAN MEGATRENDS INDIA PRIVATE LTD.,
KUMARAN NAGAR,
SEMMANCHERY VILLAGE,
CHENNAI (TN) 600119.
All product names used in this publication are for identification purposes only and are
trademarks of their respective companies.
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 2
B.O.L.T User Manual
Model No: VA07
Table of Contents
1.0
Overview......................................................................................... 4
2.0
Introduction ..................................................................................... 4
3.0
Package Contents .............................................................................. 4
4.0
Instructions for safe use ....................................................................... 5
5.0
Intended use .................................................................................... 6
6.0
Prerequisites .................................................................................... 6
7.0
Using Mobile Application ...................................................................... 6
8.0
AMI Chest ECG Measurement procedure .................................................... 6
9.0
Charging the AMI Chest ECG Devices ........................................................ 8
10.0
Explanation of Indicators/Symbols........................................................... 9
11.0
Technical Specifications...................................................................... 10
12.0
FCC compliance statements ................................................................. 10
Contact us .............................................................................................. 11
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 3
B.O.L.T User Manual
Model No: VA07
1.0 Overview
Model VA07 – AMI Chest ECG
Thank you very much for purchasing B.O.L.T the One -Touch Wireless Health Tracker. Please
read this User Manual thoroughly to ensure safe and correct use of the product. Please keep
this User Manual for future reference.
2.0 Introduction
AMI Chest ECG device is a portable diagnostic system which can measure/monitor the
electrical activity of the heart over a period of time using the ECG electrodes placed on the
user`s body. The device monitors the ECG waveform from the chest Left, Right alone with a
reference Electrode. The acquired and processed ECG data obtained from the device is
transmitted to a mobile device wirelessly for further processing and analysis. The ECG data
acquired by the device can be used to obtain clinical consultation from cardiologists or
healthcare practitioners.
AMI Chest ECG Device
ECG Electrode Cables
Charging Adaptor & USB Cable
3.0 Package Contents




AMI Chest ECG Device
ECG Electrode cables
Disposable ECG Electrodes
Charging Adaptor & USB cable for charging AMI Chest ECG device
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 4
B.O.L.T User Manual
Model No: VA07
4.0 Instructions for safe use
Warning










Read the user manual thoroughly before using the device.
Exposure of the device to water is prohibited.
Do not expose the device to strong shocks or vibrations.
Do not disassemble, repair, or modify the device by yourself, hence this could void
the user's authority to operate the device.
Remove the accessories in contact with body and switch off the units immediately.
If any pain / irritation / discomfort is encountered while using the devices &
consumables.
Adhesives present in consumables like disposable ECG electrodes are free from any
harmful substances. However if any allergic reaction / irritation is observed, remove
the part immediately from human contact. Clean the area with a mild soap and water
to remove any residual particles of adhesive.
Keep the device away from infants, small children or anyone who are incapable of
using the device in appropriate manner.
Make sure that the ECG electrodes positioning place are clean for accurate ECG
measurement as mentioned in the user manual.
Do not attempt self-diagnosis or self-treatment based on the measurements provided
by the device.
Caution



Do not use unauthorized parts and accessories.
Do not store or use this device in locations which are maintained above the specified
temperature and humidity ranges.
Wrong positioning of the ECG electrodes may lead to inaccurate readings.
Care and Maintenance





Store the device and the components in a clean and safe location.
Charge the device for minimum two hours in case of first time usage.
Do not disassemble, repair or modify the device and the components by yourself.
Wipe the device using 70% Isopropyl alcohol and let air dry.
Do not clean with ketones or other flammable agents.
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 5
B.O.L.T User Manual
Model No: VA07
5.0 Intended use
AMI Chest ECG (VA07)
It is used to acquire the ECG parameters of an adult users. The acquired ECG parameters
can be used to obtain clinical consultation from cardiologists or healthcare practitioners.
6.0 Prerequisites
Some basic requirements must be adopted as mentioned below to ensure better operation
of the product.




AMI Chest ECG device is designed to be operated with applications like Android, iOS
or Windows.
The Android OS version of the using computer/mobile device should be 4.0 or higher.
The iOS version of the using computer/mobile device should be 7 or higher.
The Windows OS version of the using computer/mobile device should be 8 or higher.
7.0 Using Mobile Application
Downloading and Installing Mobile application in your computer/mobile device
1. Download and Install the application from Play store/Application store/Windows
application market.
2. On successful installation, launch the application in the mobile device.
8.0 AMI Chest ECG Measurement procedure
1. Position the disposable ECG electrodes on the user`s body as shown below.
Note: Kindly replace all the 3 ECG electrodes after 24 hours of
usage. While replacing, do not place the electrodes on the same
position. Instead, place it slightly away / adjacent to the previous
location.
2. Ensure that the positioning spots of the human body are clean shaved.
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 6
B.O.L.T User Manual
Model No: VA07
3. Connect the ECG electrode cables to the ECG device with appropriate matching color
on connectors of the ECG device. RA is white color, LA is black color and LL is red
color. The ECG cables will also have RA, LA & LL tags as additional guideline along with
the colors.
RA – Right Arm, LA – Left Arm & LL – Left Leg.
4. Clip/button the ECG Electrode cable to the disposable ECG electrode as shown below.
5. Once the setup is connected ensure that the user is comfortable for the
measurement.
6. Switch ON the mobile device, and Enable Bluetooth & Wi-Fi Internet Connectivity.
7. Launch the mobile application from the mobile device.
8. Switch ON the ECG device using the slide power button.
9. Blue LED on the ECG device will start blinking, which means that the ECG device is
searching for Bluetooth device for pairing.
10. Scan and Select the corresponding ECG device (e.g. AMI Chest ECG 01) from the
displayed list (in case if it is requested).
11. Confirm the selection of the device.
12. Select “ECG” option to perform the monitoring/measurement.
13. Provide default pairing password 1234 for pairing the ECG device with the mobile
device (in case if it is requested).
14. Ensure that the Blue LED stops blinking in the ECG device and ready for the
measurement.
15. Monitoring vitals data will be displayed within a couple of minutes in the application
screen.
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 7
B.O.L.T User Manual
Model No: VA07
9.0 Charging the AMI Chest ECG Devices
The AMI Chest ECG is operated with an in-built rechargeable battery, which can be charged
using the power adapter and USB cable as guided below. It is mandatory to charge the
devices for a minimum period of 2 hours before the first time usage. Kindly connect the
devices to the power source, if low battery status is indicated in the mobile application
screen.
Power adapter & USB cable
AMI Chest ECG device
Charging Procedure:-
1. Connect the USB cable to the power adapter.
2. Connect the micro USB port to the ECG device`s power port (USB port).
3. Plug the adapter to the AC mains (110V, 60Hz or 230V, 50Hz).
4. Switch ON the AC mains to charge the device.
5. Check whether the power indicator turns red while charging the device.
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 8
B.O.L.T User Manual
Model No: VA07
10.0 Explanation of Indicators/Symbols
Indicators/Symbols
Function/Description
The indicator displays full battery power of the gadget in the
computer/mobile device.
The indicator displays low battery power of the gadget in the
computer/mobile device.
o Flashing of the Bluetooth light indicates that the gadget is
waiting for pairing with the mobile/tab.
o Steady Bluetooth light indicates that the gadget is paired and
ready for the measurement.
o Steady green light indicates that the gadget is operating in
battery mode.
o Blinking of green light indicates that the gadget has low
battery level.
Steady red light indicates that the gadget is in the charging mode.
Symbol for “ENVIRONMENT PROTECTION”
Symbol for “KEEP DRY”
Symbol for “MANUFACTURER”
Symbol for “MANUFACTURED DATE”
Symbol for “SERIAL NUMBER”
Symbol for “EUROPEAN REPRESENTATIVE”
Symbol for “COMPILES WITH MDD93/42/EEC REQUIREMENTS”
Symbol for “Federal Communication Commission”
Symbol for “Read the documentation”
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 9
B.O.L.T User Manual
Model No: VA07
Symbol for “Warning”
Symbol for “Temperature limitation”
Symbol for “Shock Protection”
11.0 Technical Specifications
Product Name
AMI Chest ECG
Model
VA07
AMI Chest ECG Unit
Unit Dimensions
Unit Weight
Power Source
Bluetooth
Operating Temperature
Storage and Transport Temperature
Storage Humidity
85 (L) X 40 (H) X 20 (D) mm
45 grams (Including Battery)
DC 5V 1A
Bluetooth 4.0 EDR or Lower, Bluetooth Low Energy
(BLE)
16°C to 35°C (60.8°F to 95.0°F)
10°C to 55°C (14°F to 131°F)
30%RH to 90%RH
NOTE: These specifications are subject to change without notice.
12.0 FCC compliance statements
This device complies with Part 15 of the FCC Rules. Its operation is subject to the following
two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including Interference that may cause
undesired operation.
FCC Caution

Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 10
B.O.L.T User Manual
Model No: VA07
Part 15B compliance statements for digital devices:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy And, if not installed
and used in accordance with the instructions, may Cause harmful interference to radio
communications. However, there is no Guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television Reception, which can
be determined by turning the equipment off and on
The user is encouraged to try or to correct the interference by one or more of
The following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
For more information kindly visit our website: www.amibolt.com
Contact us
AMERICAN MEGATRENDS INDIA PRIVATE LTD.,
KUMARAN NAGAR,
SEMMANCHERY VILLAGE,
CHENNAI (TN) 600119
Tel – (91) 44 66540922, Fax – (91) 44 66540901
Email: support@amibolt.com
Website: www.amibolt.com; www.amiindia.co.in
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 11
B.O.L.T User Manual
Model No: VA07
American Megatrends International GmbH
Truderingerstraße (Truderinger Strasse) 283
81825 München (Munich), Deutschland (Germany)
Tel: [49] 89 969995-10
Support: [49] 89 969995-11
Fax: [49] 89 969995-19
Email: europesales@ami.com
© Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.
Page | 12

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 12
Language                        : en-US
Tagged PDF                      : Yes
Title                           : AMI BOLT
Author                          : Balraj P
Subject                         : Keep a tab on your Health
Creator                         : Microsoft® Word 2013
Create Date                     : 2015:10:09 14:44:02+05:30
Modify Date                     : 2015:10:09 14:44:02+05:30
Producer                        : Microsoft® Word 2013
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AFV6-AMI-ECG-01

Navigation menu