ASSALOY SCSEHF H2SE User Manual rev1

ASSA ABLOY Inc. H2SE rev1

User Manual rev1.pdf

A8027G06/17Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written  permission of Sargent Manufacturing Company is prohibited. Harmony Series Mortise LockInstallation InstructionsH2
           Table of ContentsWarning  ...................................................................................2General Description .................................................................3Technical Specifications .........................................................3Regulatory Specifications .......................................................3Parts Breakdown .....................................................................4Installation Instructions ..........................................................8Wiring Diagrams ....................................................................16Mechanical Operational Check .............................................18Electrical Operational Check .................................................18A8027G • 800-810-WIRE (9473) • www.sargentlock.com 2123456789Changes or modifications to this unit not expressly approved by the party  responsible for compliance could void the user’s authority to operate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference  that may cause undesired operation.Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to  Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in  a residential installation.This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance  with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or  television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to  correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna•  Increase the separation between the equipment and receiver•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected•  Consult the dealer or an experienced technician for helpContains  FCC ID:  U4A-SCSEHF Contains  IC:  6982A-SCSEHF The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)  this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. Warning 1Observe precautions for handling electrostatic sensitive devices.!
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com3The SARGENT Harmony Series H2 mortise lock is designed to interface with existing Wiegand Electronic  Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID® iCLASS® 13.56MHz technology. Harmony Series technology is backed by SARGENT’s Grade 1 hardware. The mortise lock comes with Request to Exit (RX) monitoring within the lock body and operates from  12-24VDC. The Harmony H2 iCLASS reader provides visual (LED) and audible indicators of lock position (locked/unlocked). Gasket required for exterior door applications.•  Latch: Stainless steel, 3⁄4” projection, one-piece•  Deadbolt: One-piece hardened stainless steel•  Guardbolt: Stainless steel, non-handed•  Handed: Easily field reversible without opening case•  Case: 12 gauge heavy duty wrought steel•  Outside lever controlled by any 13.56MHz HID  iCLASS Wiegand credential•  Field-selectable to Fail Safe or Fail Secure General Description2Technical Specifications3•  Lock to be configured* as Fail Safe or  Fail Secure per AHJ compliance as part of  initial lock configuration•  Locks furnished for 1-3/4” doors. Other door thicknesses require confirmation with factory. •  UL 294 Access Control Performance Ratings: Destructive Attack Level ILine Security Level IEndurance Level IVStandby Power Level I•  ANSI/BHMA A156.25 Listed Grade 1 Compliant•  UL and CUL listed for use on Fire Doors•  This product meets the requirements of CAN/ULC-S319-05 Equipment Class IRegulatory Specifications4Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.•  Door position switch within lock body•  Inside lever provides RX signal and retracts latch and deadbolt• Reader Draw = 150mA @12VDC / 24VDC• Actuator Draw = 400mA inrush / 15mA continuous @12VDC / 24VDC• Solenoid Draw = 250mA @12VDC                               500mA @24VDC
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 4Tools Required:•  Phillips Screw Driver (Standard size)•  Slotted Screw Driver (Standard size)•  1/8" Allen WrenchParts Breakdown515121311A235869106610101614*6107B7A7
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com5Item Part #  Description Req.1 52-4039 Outside Harmony Escutcheon With Cylinder Prep  11A 52-4040 Outside Harmony Escutcheon Without Cylinder Prep 12 52-0796 Outside Weather Gasket 13 52-0795 Inside Weather Gasket 15 52-5236 Screw Pack  (5A; 5B; 5C; 5D) 16 82-4355 Trim Pack - Standard levers 179-2162 Trim Pack - Deco levers (shown)7 52-4517 H2-IA-02 Controller Assembly 17A 52-5196 Inside Escutcheon w/ Turn Assembly 17B 82-0706 Inside Escutcheon w/out Turn Prep 18 -- Reference Harmony Series Catalog For Available Lever Styles 19 -- Reference Harmony Series Catalog For Available Rose Styles 110 77-4236 Mortise screw pack - specify finish                                                                                        (includes: wood & metal lock body screws, faceplate screws & strike screws)12 -- Reference Harmony Series Catalog For Available Lever Styles 113 -- Reference Harmony Series Catalog For Available Cylinders (Size 43) 114* Lock Body†H2-82270-12/24 VDC x Finish w/out Deadbolt, Fail Safe** 1H2-82271-12/24 VDC x Finish w/out Deadbolt, Fail Secure** 1H2-82272-12/24 VDC x Finish w/out Deadbolt, Fail Safe, Both Levers Lock** 1H2-82273-12/24 VDC x Finish w/out Deadbolt, Fail Secure, Both Levers Lock** 1H2-82274-12/24 VDC x Finish w/out Deadbolt, Fail Safe** 1H2-82275-12/24 VDC x Finish w/out Deadbolt, Fail Secure** 1H2-82280-12/24 VDC x Finish w/ Deadbolt, Fail Safe** 1H2-82281-12/24 VDC x Finish w/ Deadbolt, Fail Secure** 1H2-82282-12/24 VDC x Finish w/ Deadbolt, Fail Safe, Both Levers Lock** 1H2-82283-12/24 VDC x Finish” w/ Deadbolt, Fail Secure, Both Levers Lock** 1H2-82284-12/24 VDC x Finish w/ Deadbolt, Fail Safe** 1H2-82285-12/24 VDC x Finish w/ Deadbolt, Fail Secure** 115 82-0579 Electrical Outside Faceplate w/ Deadbolt 115A 82-0578 Electrical Outside Faceplate w/out Deadbolt 116 82-0110 Strike Plate 117 01-2299 #12 X 1 1/4" Phillips Flat Head Wood Screw 221 A7944 Field Prep Template (Not Shown) 122 4590 Door Manufacturer Template (Not Shown) 123 A8027 Installation Instructions (Not Shown) 1Parts Breakdown (Continued)*Patent Pending -   www.assaabloydss.com/patents**CAUTION: Not recommended for use on any door used for Life Safety Egress†For End-of-Line Resistor and PHR locks, please consult factory
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 6Wiring Diagrams6Product 8 PIN CONNECTOR 4 PIN CONNECTOR1-Black 2-Red 3-White 4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 1-Violet 2-Gray 3-Pink 4-TanACCESS CONTROL DEVICES: Harmony H2 Mortise, ElectroLynx wire Color / Function assignmentsSARGENT -HARMONY SERIESH2 Mortise12/24VDC (Reader)WIE-GANDWIE-GANDRX RX EGND LED 12/24 VDC(LOCK RELAY)DPS (NC)DPS (COM)NEG POS DATA_1 DATA_0 NO/NC  COM REF.*DIA-GRAMSREF.*DIA-GRAMSNEG POS DPS DPSBored/Exits NEG POS DATA_1 DATA_0 ?? COM NEG POS NC NCReader LED ConfigurationThe Harmony Series reader can be configured for (3) modes of LED  operation. HID Programming cards are also supported to configure  the behavior for LED color activity. Call 1-800-810-WIRE for details. Mode 1:•  Red LED ‘ON’ when powered.•  Presenting a valid credential causes LED to ‘FLICKER’     green and return to red state.Mode 2:•  Green LED “ON” when powered.•  No Flicker after presenting valid valid credential.PIN 8 (Yellow – LED)PIN 6 (Blue – RX COM)PIN 4 (Green – Data 0)PIN 2 (Red – Reader POS)PIN 1 (Black – Reader NEG)PIN 3 (White – Data 1)PIN 5 (Orange – RX NO/NC)PIN 7 (Brown-EGND)PIN 4 (Tan – DPS COM)PIN 2 (Gray – Lock POS)PIN 1 (Violet – Lock NEG)PIN 3 (Pink – DPS NC)Mode 3:•  EAC Panel controls LED operation.   Note: Control of LED is a function of the EAC panel equipment (i.e. relay) to toggle between                                green and red.   Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on               wire or door reader performance will be impacted.*Diagram on following pageIf your lock is configured with End of Line Resistors, reference instruction sheet A8191 for the wiring of RX & DPS outputs.Note: LED wire must be connected to circuit GROUND of the system’s power supply. Total One-Way  Length of  Wire Run (ft)Load Current @ 12VDC1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A100 20 18 16 14 14 12 12 10150 18 16 14 12 12 12 10 —200 16 14 12 12 10 10 — —250 16 14 12 10 10 10 — —300 16 12 12 10 10 — — —400 14 12 10 — — — — —500 14 10 10 — — — — —7501210——————1,000 10 — — — — — — —1,500 10 — — — — — — —Wire Gauge ChartsTotal One-Way  Length of  Wire Run (ft)Load Current @ 24VDC1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A100 24 20 18 18 16 16 14 12150 22 18 16 16 14 14 12 10200 20 18 16 14 14 12 12 10250 18 16 14 14 12 12 12 10300 18 16 14 12 12 12 10 —400 18 14 12 12 10 10 — —500 16 14 12 10 10 — — —750 14 12 10 10 — — — —1,000 14 10 10 — — — — —1,500 12 10 — — — — — —Wire from EAC panel to door must be shielded with drain terminated at EAC  panel controller
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com7Typical Harmony Mortise Lock Application Diagram (12/24VDC System)12 ConductorElectroLynx HarnessFrom McKinneyHarmony Series H2Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)Harmony Series H2 Requires 12 or 24VDCUL294 Listed Power Supply (or UL603)120 VACInput 12/24VDCH    N    G-    +Black (Hot)    White (Neutral)         Green (Gnd)(-)    12/24VDC(+)DATA  1DATA  0RXRXElectronic Access Control Panel (By Others)Use (NC) for Fail Safe OperationLock Relay(NO) Fail Secure OperationDPS DPSNot UsedREADER NEG - Black, 1READER POS - Red, 2DATA 1 - White, 3DATA 0 - Green, 4RX (NO/NC) - Orange, 5RX (COM) - Blue, 6*EGND- Brown, 7LED - Yellow, 8LOCK NEG - Violet, 9LOCK POS - Gray, 10DPS (NC) - Pink, 11DPS (COM) - Tan, 12QC12 Electric  Hinge From  McKinneyLock bodyPower Supply(By Others)Reader Electronics Require 12 or 24VDC UL294 Listed Power Supply (or UL603)This product is polarity sensitive; if the lock does not operate, check the polarity of the input and reverse if necessary.12/24VDC System•  Reader Draw = 150mA @12 or 24VDC•  Actuator Draw = 15mA continuousNOTE: If your lock is configured with End of Line Resistors, reference  instruction  sheet  A8191  for  the  wiring  of             RX & DPS outputs.Harmony Series H2 UL294 Listed EAC Product*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.  Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 8Left HandHinges Left.Open Inward.“LH”Left HandReverse BevelHinges Left.Open Outward.“LHRB”Right HandHinges Right.Open Inward.“RH”Right HandReverse BevelHinges Right.Open Outward.“RHRB”Stand on outside of locked door when determining door hand.Prepare door according to appropriate template. If necessary, refer to website:  www.intelligentopenings.com.•  Prior to installation, make sure all holes are free of burrs, debris, and sharp edges.•  If doors are not properly reinforced per ANSI 115.2, commercially available reinforcements should be installed.•  Templates: •  Field prep: A7944 template ships with product. •  Manufacturer: 4590 wood and metal door template. Outside of Door Inside of DoorRaceway for 12 ConductorNetwork/Power Cable(ElectroLynx) from McKinneyHole for Cable fromReader to Controller BoardPre-drilled and/orTapped Holes (2 places)Inside Cylinder HoleThrough-bolt Holes(2 places)Outside Cylinder Hole(70/71, 80/81 functions only)Lever  Handle HoleThumb Turn Hole Lever Handle HoleMortise AreaPre-drilled and/orTapped Holes (2 Places)Fig. 1AFig. 1BA.   Verify Hand and Bevel of DoorInstallation Instructions61   Door PreparationB. Door PreparationWood DoorRaceway for 12 ConductorNetwork/Power Cable(ElectroLynx) from McKinney
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com9Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A):1.  Position lock body with red surface of  locking piece visible.2.  Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body.3.  Rotate the locking piece 180° until RED surface is on opposite side.Note: Red indicates locked side (outside).Beveled surface of latch must face strike (Fig. 2B). The deadlatch is self adjusting. To change hand of latchbolt:1.  Insert screwdriver into the spade-  shaped (triangular) slot.2.  Rotate screwdriver 90º to push latch out  until back of latch clears lock front; then  rotate latch 180º. Latch will then re-enter lock body.Note: Latch cannot be unscrewed.Fig.  2ALocking Guide Slot:Red color indicateslocked side. Push InRight  HandLock Shown2   How to Change Hand of Lock bodyA.   Reverse Lock HandB.  Reverse Latch HandTriangular SlotLatchboltFig.  2B3  Configure the DIP Switch SettingsDIP Switch1 2 3HandingRH & RHR   LH & LHRActuator OperationFail Safe Fail SecureRX OutputNormally OpenNormally ClosedCheck Polarity:             Verify + (red wire)IMPORTANT: This product is built and factory tested to the configuration specified.  Any change to the 3-position DIP-switch settings located at the bottom of the mortise lock body must be made prior to lock installation.
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 101. Wires and connectors go into the mortised area and out of the         inside cylinder hole.2. Insert mortise lock body into mortise door preparation.3. Carefully feed wires from mortise lock through the non-cylinder      side hole of the door preparation. 4. Install appropriate hardware lock body screws.    NOTE: Do not tighten screws completely at this time.    Cylinder should be installed prior to tightening.Inside of Door(2)#12 x 1-1/4” Long Flat Head Wood Screws (Wood Doors)Fig. 4(2) #12-24 x 1/2” Long  FlatHead Philips Screws (Metal Doors)Feed connectorsand wires throughnon-cylinder side. 4   Install Lock body5   Outside Escutcheon and Mounting Plate InstallationNOTE: Feed mortise connectors through the corresponding hole on the mounting plate. 1.  Attach the mounting plate using (2) 8-32 x 2" Phillips flat head  undercut combo screws in the upper right and middle left  positions of the mounting plate and (2) 8-32 x 3/8" Phillips flat head  screws in the bottom positions (Fig. 5A).Fig. 5A(2) 8-32 x 3/8” Phillips Flat Head Undercut Combo Screw(2) 8-32 x 3/8” Phillips Flat Head ScrewInside of Door12 ConductorNetwork/Power Cable(ElectroLynx) from McKinney
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com11Remember to install inside gasket when  lock is being used in an outdoor application. 1. Add gasket (if necessary):Gasket fits snug around plate at top and sides,  leaving room for the hole at the bottom. 2. Remove (peel) backing and place gasket      on door (Fig. 6).  6  Install Inside Gasket (if necessary)Required for exteriordoor applications.Fig.  6Inside of DoorFig. 5BGasket required for exterior door applicationsReader CableOutside of Door2.  Feed the reader cable located on the back of the outside  escutcheon through the door prep (Fig. 5B). 3.  Outside gasket must be used when installing Harmony in an outdoor application (Fig. 5B).4.  Secure the mounting plate to the outside escutcheon with  (2) #8-32 x 2” flat head machine screws (Fig. 5C).5  Outside Escutcheon and Inside Mounting Plate Installation (Continued)Fig. 5CInside of Door
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 12Fig.  8B1.  Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 8A).2.  Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig. 8B).3.  Use the key to rotate the cylinder clockwise until it is flush at the bottom and the SARGENT logo is right-side up.Do not attempt to tighten all the way.4.  Tighten the cylinder clamp set screw to prevent  unscrewing of the cylinder (Fig. 8C).5. Test cylinder function:  •  70/71 Function: Key retracts latch. •  80/81 Function: Key retracts latch  and projects/retracts deadbolt.•  Ensure smooth operation of  latchbolt and deadbolt.NOTE: Use lever handle holes  to manipulate mortise to ease thread engagement of cylinder.Fig.  8CCylinder Set ScrewPhillips ScrewdriverOutside of Door7   Outside Cylinder Installation Correct            Incorrect
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 131.  With outside lever horizontal, insert the mounting post through outside of door and lock body.    Make certain the lever spindle is properly engaged inside the lock body (Fig. 9A).2.  On the inside of the door, insert slotted spindle into square hole of mortise lock (Fig. 9B), with spindle slot directed away from the lock body, and aligned with the set screw hole in the inside adapter.3.  Slide inside adapter and plate assembly over spindle and loosely secure with (2) 8-32 X 5/8” Phillips oval head and lock washer machine screws.    NOTE: Ensure that position of set screw hole and spinsdle slot are oriented to match location of                 hole in the inside lever handle.4.  Securely tighten the lock body screws.Fig.  9BFig.  9A(2)8-32 X 5/8” Phillips Oval Head and Lock WasherMachineScrewsMortiseLock bodyScrewsInside of DoorOutside of Door8   Outside Lever and Inside Adapter Plate Assembly Installation
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com149   Installing ControllerPlease follow these steps prior to installing inside escutcheon to prevent any damage caused by pinching wires:  1. Feed controller harness earth ground into and around behind rim     of large upper hole of the mounting plate (Fig. 10A, B). Fig.  10B J1 J2Earth groundb. Connect ElectroLynx harness (4 and 8-pin) from door harness to       ElectroLynx harness on interior PCB assembly (Fig. 10A, D).      NOTES: Neatly fold the wires into the remaining space to prevent                     pinching wires when mounting escutcheon.        Do not tuck extra mortise lock body wires back                                   inside the lock body cylinder hole.                    Connectors go on only one way.                    Do not offset connector and be sure they are          completely seated.PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)J2 J11-Violet Lock NegActuator (+) Solenoid (-)3-PinkDPS (NC)1- BlackPWR NEG3-WhiteDATA 15-OrangeRX (NO/NC)7-Brown EGND2-Gray Lock PosActuator (+) Solenoid (-)4-TanDPS (COM)2-Red PWR POS4-GreenDATA 06-BlueRX (COM)8-YellowLED Connect ElectroLynx® P58-pin               ElectroLynx4-pin               ElectroLynx J5Fig.  10Aa. Connect P5 (7 Pin Connector) from reader board to J5 on interior       escutcheon PCB assembly (Fig. 10C).  P5Inside of DoorInside of DoorFig.  10CFig.  10DController PCB
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 15c. Position two-wire green/yellow ground wire ring terminal (from lock body)      over hole for top      left screw (Fig. 11B, C). d. Position green/yellow reader harness earth ground on top of two-wire     ground ring and thread both with (1) 8-32 x 3/8” Phillips flat head undercut       combo screw (Fig. 11C, D).IMPORTANT: Note orientation of ground ring terminals in Fig. 11B-D. e. Tighten securely.Fig.  11BOnce wires are arranged, position controller at a rotated angle against the door, under earth ground wire. a. Press piece against door while turning clockwise (Fig. 11A). b. Twist into place, perpendicular with door (Fig. 11B). Install ControllerInside of DoorRotate ClockwiseFig.  11A(2) 8-32 x 3/8” Phillips Flat Head Undercut Combo ScrewFig.  11CFig.  11D
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com161.  Connect P3 (2-pin connector) from lock body  to J3 on module (Fig. 12). 2.  Connect P4 (6-pin connector) from lock body  to J4 on module (Fig. 12). 12   Connector Attachment (Exterior PCB Assembly)13  Install Inside Escutcheon Assembly1. Tighten the inside escutcheon securely to the                mounting plate with the Phillips flat head machine             screws provided.      Use the 8-32 x 5/8” for the top of the escutcheon      and the 8-32 x 1/4” screws for the bottom of the      escutcheon located under the turn lever (Fig. 13).          NOTE: The inside gasket (not shown) must be used      when installing Harmony in an outdoor application          (refer to previous Step 6).2. Be sure the turn assembly is functional      and the deadbolt functions properly.Fig.  138-32 X 1/4” Phillips Flat Head UndercutMachine Screw8-32 X 5/8” Phillips Flat Head UndercutMachine ScrewInside of Door P4 P3
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.03/31/17Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com17Fig.  14A Fig. 14BSet ScrewInside LeverSpindleInside of DoorRose14   Inside Rose and Inside Lever Assembly Instructions1. Attach front plate with (2) 8-32x1/4” flat head screws      and tighten securely.Fig.  15(2) 8-32x1/4” Flat Head ScrewsLock Body ScrewLock Body ScrewOutside of Door15  Attach Front Plate1. Rotate the inside rose - first counter clock      wise to seat the threads and then, clockwise       to securely tighten.2. Slide lever handle onto spindle until fully      seated. Be sure handle is horizontal and      facing the hinge side of the door. Push lever      onto spindle so minimum gap is visible.3. Tighten the set screw securely with       a 1/8” hex wrench.4. Before closing the door, test that      lever is functional and ensure      smooth operation of the      latchbolt and deadbolt.
03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027G • 800-810-WIRE (9473) • www.sargentlock.com 18For 82280-82283 & 82270-82273 Function mortise locks with cylinders:1. Insert key into cylinder and rotate: There should be no friction against     lock case, wire harness or any other obstructions.2. The key will retract the latch: Key should rotate freely.3. When the deadbolt is thrown: Ensure that the key retracts both the     deadbolt and the latch.4. Inside lever: When used, ensure it retracts both the latch      and deadbolt (if provided).5. Close door: Ensure latch and deadbolt fully extend      and do not bind.Note: Once electrical wiring has been successfully completed according to proper application, follow the following steps:1. Turn power ON.2. Verify LED located on reader is ON (Red or Green     depending on reader configuration (See reader LED     Configuration). 3. Present proximity credential and verify LED and     sounder activity.4. Verify valid card read at EAC panel. 5. Verify system operation functions; i.e., present valid Prox credential       to reader and unlock door.Mechanical Operational Check9Electrical Operational Check10Feature WT1 WT212 or 24VDC solenoid lock voltage adjustable X XOperates as Fail Safe or Fail Secure X X"Learn" mode allows testing of specific cards without programming at the panel levelX XCard reader data inte-grity is validated at test unitX XWorks with SE LP10 X XDisplays detailed Wiegand data, including hexadecimal string and total bits receivedXDisplays measured end-of-line resistor values     (if applicable)XThe ASSA ABLOY Wiegand Test Unit verifies your installation in the field. The test unit checks for proper wiring, card reader data integrity, lock functionality including lock/unlock, door position status, and request-to-exit (REX) status.In addition, this tool provides product demonstration abilities to highlight the product’s features and capabilities.Wiegand Test Unit
A8027G-06/17SARGENT Manufacturing100 Sargent DriveNew Haven, CT 06511 USA800-727-5477 •  www.sargentlock.comFounded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.Sargent Manufacturing Company (New Haven, CT). 2017. Patent pending and/or patent -  www.assaabloydss.com/patents.HID, iCLASS, and Edge are trademarks or registered trademarks of HID Global Corporation. ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience.