H2
Harmony Series
Mortise Lock
Installation Instructions
A8027G
06/17
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Warning ....................................................................................2
General Description..................................................................3
Technical Specifications..........................................................3
Regulatory Specifications........................................................3
Parts Breakdown......................................................................4
Installation Instructions...........................................................8
Wiring Diagrams.....................................................................16
Mechanical Operational Check..............................................18
Electrical Operational Check..................................................18
Warning
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
•
Consult the dealer or an experienced technician for help
Contains FCC ID: U4A-SCSEHF
Contains IC: 6982A-SCSEHF
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were
met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des
règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and
SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific
situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated
opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance
with all applicable codes and ratings.
Observe precautions for handling electrostatic sensitive devices.
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
General Description
The SARGENT Harmony Series H2 mortise lock is designed to interface with existing Wiegand Electronic
Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID®
iCLASS® 13.56MHz technology. Harmony Series technology is backed by SARGENT’s Grade 1 hardware.
The mortise lock comes with Request to Exit (RX) monitoring within the lock body and operates from
12-24VDC. The Harmony H2 iCLASS reader provides visual (LED) and audible indicators of lock position
(locked/unlocked). Gasket required for exterior door applications.
Technical Specifications
•
Latch: Stainless steel, 3⁄4” projection, one-piece
•
Door position switch within lock body
•
Deadbolt: One-piece hardened stainless steel
•
•
Guardbolt: Stainless steel, non-handed
Inside lever provides RX signal and retracts
latch and deadbolt
•
Handed: Easily field reversible without opening case
•
•
Case: 12 gauge heavy duty wrought steel
Lock to be configured* as Fail Safe or
Fail Secure per AHJ compliance as part of
initial lock configuration
•
Outside lever controlled by any 13.56MHz HID
iCLASS Wiegand credential
•
Locks furnished for 1-3/4” doors. Other door
thicknesses require confirmation with factory.
•
Field-selectable to Fail Safe or Fail Secure
4 Regulatory Specifications
03/31/17
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
• Reader Draw = 150mA @12VDC / 24VDC
• Actuator Draw = 400mA inrush / 15mA continuous @12VDC / 24VDC
• Solenoid Draw = 250mA @12VDC
500mA @24VDC
• UL 294 Access Control Performance Ratings:
Destructive Attack
Level I
Line Security
Level I
Endurance
Level IV
Standby Power
Level I
•
ANSI/BHMA A156.25 Listed Grade 1 Compliant
•
UL and CUL listed for use on Fire Doors
•
This product meets the requirements of CAN/ULC-S319-05 Equipment Class I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Parts Breakdown
7A
7B
1A
13
10
15
16
14*
Tools Required:
•
Phillips Screw Driver (Standard size)
•
Slotted Screw Driver (Standard size)
•
1/8" Allen Wrench
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
10
10
10
03/31/17
12
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Harmony Series H2 Mortise Lock
Parts Breakdown (Continued)
Item
Part #
Description
52-4039
Outside Harmony Escutcheon With Cylinder Prep
1A
52-4040
Outside Harmony Escutcheon Without Cylinder Prep
52-0796
Outside Weather Gasket
52-0795
Inside Weather Gasket
52-5236
Screw Pack (5A; 5B; 5C; 5D)
82-4355
Trim Pack - Standard levers
79-2162
Trim Pack - Deco levers (shown)
52-4517
H2-IA-02 Controller Assembly
7A
52-5196
Inside Escutcheon w/ Turn Assembly
7B
82-0706
Inside Escutcheon w/out Turn Prep
--
Reference Harmony Series Catalog For Available Lever Styles
--
Reference Harmony Series Catalog For Available Rose Styles
10
77-4236
12
--
Reference Harmony Series Catalog For Available Lever Styles
13
--
Reference Harmony Series Catalog For Available Cylinders (Size 43)
H2-82270-12/24 VDC x Finish
w/out Deadbolt, Fail Safe**
H2-82271-12/24 VDC x Finish
w/out Deadbolt, Fail Secure**
H2-82272-12/24 VDC x Finish
w/out Deadbolt, Fail Safe, Both Levers Lock**
H2-82273-12/24 VDC x Finish
w/out Deadbolt, Fail Secure, Both Levers Lock**
H2-82274-12/24 VDC x Finish
w/out Deadbolt, Fail Safe**
H2-82275-12/24 VDC x Finish
w/out Deadbolt, Fail Secure**
H2-82280-12/24 VDC x Finish
w/ Deadbolt, Fail Safe**
H2-82281-12/24 VDC x Finish
w/ Deadbolt, Fail Secure**
H2-82282-12/24 VDC x Finish
w/ Deadbolt, Fail Safe, Both Levers Lock**
H2-82283-12/24 VDC x Finish”
w/ Deadbolt, Fail Secure, Both Levers Lock**
H2-82284-12/24 VDC x Finish
w/ Deadbolt, Fail Safe**
H2-82285-12/24 VDC x Finish
w/ Deadbolt, Fail Secure**
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
14*
03/31/17
Req.
Mortise screw pack - specify finish
(includes: wood & metal lock body screws, faceplate screws & strike screws)
†
Lock Body
15
82-0579
Electrical Outside Faceplate w/ Deadbolt
15A
82-0578
Electrical Outside Faceplate w/out Deadbolt
16
82-0110
Strike Plate
17
01-2299
#12 X 1 1/4" Phillips Flat Head Wood Screw
21
A7944
Field Prep Template (Not Shown)
22
4590
Door Manufacturer Template (Not Shown)
23
A8027
Installation Instructions (Not Shown)
*Patent Pending - www.assaabloydss.com/patents
**CAUTION: Not recommended for use on any door used for Life Safety Egress
†
For End-of-Line Resistor and PHR locks, please consult factory
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Wiring Diagrams
Product
8 PIN CONNECTOR
1-Black
2-Red
3-White
4-Green
5-Orange
4 PIN CONNECTOR
6-Blue
7-Brown
8-Yellow
1-Violet
2-Gray
3-Pink
4-Tan
DPS
(NC)
DPS
(COM)
ACCESS CONTROL DEVICES: Harmony H2 Mortise, ElectroLynx wire Color / Function assignments
SARGENT HARMONY
SERIES
12/24VDC
(Reader)
WIEGAND
WIEGAND
RX
RX
EGND
LED
REF.
*DIAGRAMS
REF.
*DIAGRAMS
NEG
POS
DATA_1
DATA_0
NO/NC
COM
NEG
POS
DATA_1
DATA_0
??
COM
H2 Mortise
Bored/Exits
12/24 VDC
(LOCK RELAY)
NEG
POS
DPS
DPS
NEG
POS
NC
NC
*Diagram on following page
If your lock is configured with End of Line Resistors, reference instruction sheet A8191 for the wiring of
RX & DPS outputs.
Reader LED Configuration
The Harmony Series reader can be configured for (3) modes of LED
operation. HID Programming cards are also supported to configure
the behavior for LED color activity. Call 1-800-810-WIRE for details.
PIN 8 (Yellow – LED)
PIN 6 (Blue – RX COM)
PIN 4 (Green – Data 0)
PIN 2 (Red – Reader POS)
Mode 1:
•
Presenting a valid credential causes LED to ‘FLICKER’
green and return to red state.
PIN 1 (Black – Reader NEG)
PIN 3 (White – Data 1)
PIN 5 (Orange – RX NO/NC)
PIN 7 (Brown-EGND)
Mode 2:
•
Green LED “ON” when powered.
•
No Flicker after presenting valid valid credential.
PIN 4 (Tan – DPS COM)
PIN 2 (Gray – Lock POS)
Note: LED wire must be connected to circuit GROUND of
the system’s power supply.
PIN 1 (Violet – Lock NEG)
Mode 3:
•
PIN 3 (Pink – DPS NC)
EAC Panel controls LED operation.
Note: Control of LED is a function of the EAC panel equipment (i.e. relay) to toggle between
green and red.
Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on
wire or door reader performance will be impacted.
Wire from EAC panel to door must be shielded with drain terminated at EAC panel controller
Wire Gauge Charts
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 12VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
Total
One-Way
Length of
Wire Run (ft)
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
100
20
18
16
14
14
12
12
10
100
24
20
18
18
16
16
14
12
150
18
16
14
12
12
12
10
—
150
22
18
16
16
14
14
12
10
200
16
14
12
12
10
10
—
—
200
20
18
16
14
14
12
12
10
250
16
14
12
10
10
10
—
—
250
18
16
14
14
12
12
12
10
300
16
12
12
10
10
—
—
—
300
18
16
14
12
12
12
10
—
400
14
12
10
—
—
—
—
—
400
18
14
12
12
10
10
—
—
500
14
10
10
—
—
—
—
—
500
16
14
12
10
10
—
—
—
750
12
10
—
—
—
—
—
—
750
14
12
10
10
—
—
—
—
1,000
10
—
—
—
—
—
—
—
1,000
14
10
10
—
—
—
—
—
1,500
10
—
—
—
—
—
—
—
1,500
12
10
—
—
—
—
—
—
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Load Current @ 24VDC
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Red LED ‘ON’ when powered.
03/31/17
•
Harmony Series H2 Mortise Lock
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
Typical Harmony Mortise Lock Application Diagram (12/24VDC System)
Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)
Reader Electronics Require 12 or 24VDC UL294 Listed Power Supply (or UL603)
12/24VDC System
•
Reader Draw = 150mA @12 or 24VDC
•
Actuator Draw = 15mA continuous
ck
Bla
t)
(Ho
hit
This product is polarity sensitive; if the lock
does not operate, check the polarity of the
input and reverse if necessary.
120 VAC
Input
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
d)
Gn
en
Gr
Harmony Series H2
Requires 12 or 24VDC
UL294 Listed Power
Supply (or UL603)
12/24VDC
03/31/17
al)
utr
(Ne
Lock body
Power Supply
(By Others)
Harmony Series H2
UL294 Listed EAC
Product
READER NEG - Black, 1
(-)
READER POS - Red, 2
12 Conductor
ElectroLynx Harness
From McKinney
QC12 Electric
Hinge From
McKinney
(+)
DATA 1 - White, 3
12/24VDC
DATA 1
DATA 0 - Green, 4
DATA 0
RX (NO/NC) - Orange, 5
RX
RX (COM) - Blue, 6
RX
*EGND- Brown, 7
LED - Yellow, 8
Not Used
Use (NC) for
Fail Safe
Operation
Lock Relay
LOCK NEG - Violet, 9
Harmony Series H2
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
Electronic
Access
Control
Panel
(By Others)
DPS
DPS
(NO) Fail
Secure
Operation
NOTE:
If your lock is configured with End of Line Resistors,
reference instruction sheet A8191 for the wiring of
RX & DPS outputs.
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Installation Instructions
1 Door Preparation
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
Left Hand
Hinges Left.
Open Inward.
“LH”
Left Hand
Reverse Bevel
Hinges Left.
Open Outward.
“LHRB”
Right Hand
Hinges Right.
Open Inward.
“RH”
Fig. 1A
Right Hand
Reverse Bevel
Hinges Right.
Open Outward.
“RHRB”
B. Door Preparation
Prior to installation, make sure all holes are free of burrs, debris, and sharp edges.
•
If doors are not properly reinforced per ANSI 115.2, commercially available reinforcements
should be installed.
•
Templates:
•
Field prep: A7944 template ships with product.
•
Manufacturer: 4590 wood and metal door template.
Outside of Door
Inside of Door
Wood Door
Through-bolt Holes
(2 places)
Raceway for 12 Conductor
Network/Power Cable
(ElectroLynx) from McKinney
Hole for Cable from
Reader to Controller Board
Raceway for 12 Conductor
Network/Power Cable
(ElectroLynx) from McKinney
Pre-drilled and/or
Tapped Holes (2 places)
Inside Cylinder Hole
Outside Cylinder Hole
(70/71, 80/81
functions only)
Thumb Turn Hole
Lever Handle Hole
Lever Handle Hole
Mortise
Area
Pre-drilled and/or
Tapped Holes (2 Places)
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Fig. 1B
03/31/17
•
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Prepare door according to appropriate template. If necessary, refer to website:
www.intelligentopenings.com.
Harmony Series H2 Mortise Lock
2 How to Change Hand of Lock body
A. Reverse Lock Hand
Red surface of locking piece must face the
outside/locked side of door. To rotate locking
piece (Fig. 2A):
Right Hand
Lock Shown
1. Position lock body with red surface of
locking piece visible.
2. Insert blade type screwdriver into locking
piece slot to rotate locking piece toward
back of lock body.
Locking Guide Slot:
Red color indicates
locked side.
3. Rotate the locking piece 180° until RED
surface is on opposite side.
Fig. 2A
Push In
Note: Red indicates locked side (outside).
B. Reverse Latch Hand
Beveled surface of latch must face strike (Fig. 2B).
Triangular Slot
The deadlatch is self adjusting.
To change hand of latchbolt:
1. Insert screwdriver into the spadeshaped (triangular) slot.
Latchbolt
03/31/17
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
2. Rotate screwdriver 90º to push latch out
until back of latch clears lock front; then
rotate latch 180º.
Latch will then re-enter lock body.
Note: Latch cannot be unscrewed.
Fig. 2B
3 Configure the DIP Switch Settings
IMPORTANT: This product is built and factory tested to the
configuration specified. Any change to the 3-position DIP-switch
settings located at the bottom of the mortise lock body must be
made prior to lock installation.
Handing
RH & RHR
12 3
LH & LHR
Check Polarity:
Verify + (red wire)
DIP Switch
Actuator Operation
Fail Safe
Fail Secure
RX Output
Normally
Open
Normally
Closed
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
4 Install Lock body
1. Wires and connectors go into the mortised area and out of the
inside cylinder hole.
Inside of
Door
2. Insert mortise lock body into mortise door preparation.
3. Carefully feed wires from mortise lock through the non-cylinder
side hole of the door preparation.
12 Conductor
Network/Power
Cable
(ElectroLynx)
from McKinney
4. Install appropriate hardware lock body screws.
NOTE: Do not tighten screws completely at this time.
Cylinder should be installed prior to tightening.
Feed connectors
and wires through
non-cylinder side.
(2) #12-24 x 1/2” Long Flat
Head Philips Screws (Metal Doors)
Fig. 4
5 Outside Escutcheon and Mounting Plate Installation
NOTE: Feed mortise connectors through the corresponding hole on the mounting plate.
1. Attach the mounting plate using (2) 8-32 x 2" Phillips flat head
undercut combo screws in the upper right and middle left
positions of the mounting plate and (2) 8-32 x 3/8" Phillips flat head
screws in the bottom positions (Fig. 5A).
Inside of
Door
(2) 8-32 x 3/8” Phillips
Flat Head Undercut
Combo Screw
(2) 8-32 x 3/8”
Phillips Flat
Head Screw
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
(2)#12 x 1-1/4” Long Flat Head Wood
Screws (Wood Doors)
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
10
03/31/17
Fig. 5A
Harmony Series H2 Mortise Lock
5 Outside Escutcheon and Inside Mounting Plate Installation (Continued)
2. Feed the reader cable located on the back of the outside
escutcheon through the door prep (Fig. 5B).
3. Outside gasket must be used when installing Harmony in an
outdoor application (Fig. 5B).
4. Secure the mounting plate to the outside escutcheon with
(2) #8-32 x 2” flat head machine screws (Fig. 5C).
Inside of Door
Outside of Door
Gasket required
for exterior door
applications
Reader Cable
03/31/17
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 5C
Fig. 5B
6 Install Inside Gasket (if necessary)
Remember to install inside gasket when
lock is being used in an outdoor application.
Inside of Door
1. Add gasket (if necessary):
Gasket fits snug around plate at top and sides,
leaving room for the hole at the bottom.
2. Remove (peel) backing and place gasket
on door (Fig. 6).
Required for exterior
door applications.
Fig. 6
11
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
7 Outside Cylinder Installation
1. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 8A).
2. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig. 8B).
3. Use the key to rotate the cylinder clockwise until it is flush at the bottom and the SARGENT
logo is right-side up.
Do not attempt to tighten all the way.
4. Tighten the cylinder clamp set screw to prevent
unscrewing of the cylinder (Fig. 8C).
5. Test cylinder function:
•
70/71 Function: Key retracts latch.
•
80/81 Function: Key retracts latch
and projects/retracts deadbolt.
•
Ensure smooth operation of
latchbolt and deadbolt.
Correct
NOTE: Use lever handle holes
to manipulate mortise to ease
thread engagement of cylinder.
Incorrect
Phillips
Screwdriver
Fig. 8B
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Fig. 8C
12
03/31/17
Cylinder Set Screw
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Outside of Door
Harmony Series H2 Mortise Lock
8 Outside Lever and Inside Adapter Plate Assembly Installation
1. With outside lever horizontal, insert the mounting post through outside of door and lock body.
Make certain the lever spindle is properly engaged inside the lock body (Fig. 9A).
2. On the inside of the door, insert slotted spindle into square hole of mortise lock (Fig. 9B),
with spindle slot directed away from the lock body, and aligned with the set screw hole in the
inside adapter.
3. Slide inside adapter and plate assembly over spindle and loosely secure with (2) 8-32 X 5/8”
Phillips oval head and lock washer machine screws.
NOTE: Ensure that position of set screw hole and spinsdle slot are oriented to match location of
hole in the inside lever handle.
4. Securely tighten the lock body screws.
Inside of
Door
Mortise
Lock body
Screws
Fig. 9A
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
13
Fig. 9B
03/31/17
(2)8-32 X 5/8”
Phillips Oval
Head and
Lock Washer
Machine
Screws
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Outside of
Door
Harmony Series H2 Mortise Lock
9 Installing Controller
Please follow these steps prior to installing inside escutcheon to
prevent any damage caused by pinching wires:
Inside of
Door
1. Feed controller harness earth ground into and around behind rim
of large upper hole of the mounting plate (Fig. 10A, B).
Inside of
Door
P5
Controller PCB
Fig. 10B
Earth
ground
J5
J2
Fig. 10A
03/31/17
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
J1
Connect ElectroLynx®
a. Connect P5 (7 Pin Connector) from reader board to J5 on interior
escutcheon PCB assembly (Fig. 10C).
P5
Fig. 10C
b. Connect ElectroLynx harness (4 and 8-pin) from door harness to
ElectroLynx harness on interior PCB assembly (Fig. 10A, D).
8-pin
ElectroLynx
NOTES: Neatly fold the wires into the remaining space to prevent
pinching wires when mounting escutcheon.
Do not tuck extra mortise lock body wires back
inside the lock body cylinder hole.
Connectors go on only one way.
Do not offset connector and be sure they are
completely seated.
Fig. 10D
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
4-pin
ElectroLynx
J1
1-Violet Lock Neg
3-Pink
1- Black
3-White
5-Orange
7-Brown
Actuator (+)
Solenoid (-)
DPS (NC)
PWR NEG
DATA 1
RX (NO/NC)
EGND
2-Gray Lock Pos
4-Tan
2-Red
4-Green
6-Blue
8-Yellow
Actuator (+)
Solenoid (-)
DPS (COM)
PWR POS
DATA 0
RX (COM)
LED
14
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Install Controller
Once wires are arranged, position controller at a rotated angle against the door,
under earth ground wire.
a. Press piece against door while turning clockwise (Fig. 11A).
b. Twist into place, perpendicular with door (Fig. 11B).
c. Position two-wire green/yellow ground wire ring terminal (from lock body)
over hole for top
left screw (Fig. 11B, C).
d. Position green/yellow reader harness earth ground on top of two-wire
ground ring and thread both with (1) 8-32 x 3/8” Phillips flat head undercut
combo screw (Fig. 11C, D).
IMPORTANT: Note orientation of ground ring terminals in Fig. 11B-D.
e. Tighten securely.
Inside of
Door
Fig. 11B
Rotate Clockwise
Fig. 11A
Fig. 11C
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
15
03/31/17
Fig. 11D
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
(2) 8-32 x 3/8” Phillips
Flat Head Undercut
Combo Screw
Harmony Series H2 Mortise Lock
12 Connector Attachment (Exterior PCB Assembly)
1. Connect P3 (2-pin connector) from lock body
to J3 on module (Fig. 12).
2. Connect P4 (6-pin connector) from lock body
to J4 on module (Fig. 12).
P3
P4
13 Install Inside Escutcheon Assembly
03/31/17
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Inside of Door
1. Tighten the inside escutcheon securely to the
mounting plate with the Phillips flat head machine
screws provided.
Use the 8-32 x 5/8” for the top of the escutcheon
and the 8-32 x 1/4” screws for the bottom of the
escutcheon located under the turn lever (Fig. 13).
8-32 X 5/8” Phillips
Flat Head Undercut
Machine Screw
NOTE: The inside gasket (not shown) must be used
when installing Harmony in an outdoor application
(refer to previous Step 6).
2. Be sure the turn assembly is functional
and the deadbolt functions properly.
8-32 X 1/4” Phillips
Flat Head Undercut
Machine Screw
Fig. 13
16
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
14 Inside Rose and Inside Lever Assembly Instructions
1. Rotate the inside rose - first counter clock
wise to seat the threads and then, clockwise
to securely tighten.
Inside of Door
2. Slide lever handle onto spindle until fully
seated. Be sure handle is horizontal and
facing the hinge side of the door. Push lever
onto spindle so minimum gap is visible.
3. Tighten the set screw securely with
a 1/8” hex wrench.
Spindle
4. Before closing the door, test that
lever is functional and ensure
smooth operation of the
latchbolt and deadbolt.
Rose
Set Screw
03/31/17
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 14A
Inside Lever
Fig. 14B
15 Attach Front Plate
1. Attach front plate with (2) 8-32x1/4” flat head screws
and tighten securely.
Outside of Door
Lock Body Screw
(2) 8-32x1/4”
Flat Head Screws
Fig. 15
Lock Body Screw
17
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Mechanical Operational Check
For 82280-82283 & 82270-82273 Function mortise locks with cylinders:
1. Insert key into cylinder and rotate: There should be no friction against
lock case, wire harness or any other obstructions.
2. The key will retract the latch: Key should rotate freely.
3. When the deadbolt is thrown: Ensure that the key retracts both the
deadbolt and the latch.
4. Inside lever: When used, ensure it retracts both the latch
and deadbolt (if provided).
5. Close door: Ensure latch and deadbolt fully extend
and do not bind.
10
Electrical Operational Check
Note: Once electrical wiring has been successfully
completed according to proper application, follow
the following steps:
1. Turn power ON.
2. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader LED
Configuration).
3. Present proximity credential and verify LED and
sounder activity.
Feature
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product’s features and capabilities.
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
18
WT1
WT2
12 or 24VDC solenoid
lock voltage adjustable
Operates as Fail Safe or
Fail Secure
"Learn" mode allows
testing of specific cards
without programming at
the panel level
Card reader data integrity is validated at test
unit
Works with SE LP10
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
Displays measured endof-line resistor values
(if applicable)
03/31/17
5. Verify system operation functions; i.e., present valid Prox credential
to reader and unlock door.
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
4. Verify valid card read at EAC panel.
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-727-5477 • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Sargent Manufacturing Company (New Haven, CT). 2017. Patent pending and/or patent - www.assaabloydss.com/patents.
HID, iCLASS, and Edge are trademarks or registered trademarks of HID Global Corporation.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A8027G-06/17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Create Date                     : 2017:04:24 09:54:51-04:00
Metadata Date                   : 2017:04:24 10:23:53-04:00
Modify Date                     : 2017:04:24 10:23:53-04:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Instance ID                     : uuid:129c0a9d-8f29-4747-95c5-a2382b871490
Original Document ID            : adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985
Document ID                     : xmp.id:d48c1ca4-dcdf-854b-b8f0-99baee861e27
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:0625a9df-af8c-d84e-81d4-3e445a5d13ee
Derived From Document ID        : xmp.did:aae23e9a-a405-6043-8e5b-186006e65f32
Derived From Original Document ID: adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2017:04:24 09:54:51-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 20
Creator                         : Adobe InDesign CC 2017 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCSEHF

Navigation menu