H2 Harmony Series Mortise Lock Installation Instructions A8027G 06/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Table of Contents Warning ....................................................................................2 General Description..................................................................3 Technical Specifications..........................................................3 Regulatory Specifications........................................................3 Parts Breakdown......................................................................4 Installation Instructions...........................................................8 Wiring Diagrams.....................................................................16 Mechanical Operational Check..............................................18 Electrical Operational Check..................................................18 Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced technician for help Contains FCC ID: U4A-SCSEHF Contains IC: 6982A-SCSEHF The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. Observe precautions for handling electrostatic sensitive devices. A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock General Description The SARGENT Harmony Series H2 mortise lock is designed to interface with existing Wiegand Electronic Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID® iCLASS® 13.56MHz technology. Harmony Series technology is backed by SARGENT’s Grade 1 hardware. The mortise lock comes with Request to Exit (RX) monitoring within the lock body and operates from 12-24VDC. The Harmony H2 iCLASS reader provides visual (LED) and audible indicators of lock position (locked/unlocked). Gasket required for exterior door applications. Technical Specifications • Latch: Stainless steel, 3⁄4” projection, one-piece • Door position switch within lock body • Deadbolt: One-piece hardened stainless steel • • Guardbolt: Stainless steel, non-handed Inside lever provides RX signal and retracts latch and deadbolt • Handed: Easily field reversible without opening case • • Case: 12 gauge heavy duty wrought steel Lock to be configured* as Fail Safe or Fail Secure per AHJ compliance as part of initial lock configuration • Outside lever controlled by any 13.56MHz HID iCLASS Wiegand credential • Locks furnished for 1-3/4” doors. Other door thicknesses require confirmation with factory. • Field-selectable to Fail Safe or Fail Secure 4 Regulatory Specifications 03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. • Reader Draw = 150mA @12VDC / 24VDC • Actuator Draw = 400mA inrush / 15mA continuous @12VDC / 24VDC • Solenoid Draw = 250mA @12VDC 500mA @24VDC • UL 294 Access Control Performance Ratings: Destructive Attack Level I Line Security Level I Endurance Level IV Standby Power Level I • ANSI/BHMA A156.25 Listed Grade 1 Compliant • UL and CUL listed for use on Fire Doors • This product meets the requirements of CAN/ULC-S319-05 Equipment Class I Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction. A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock Parts Breakdown 7A 7B 1A 13 10 15 16 14* Tools Required: • Phillips Screw Driver (Standard size) • Slotted Screw Driver (Standard size) • 1/8" Allen Wrench A8027G • 800-810-WIRE (9473) • www.sargentlock.com 10 10 10 03/31/17 12 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Harmony Series H2 Mortise Lock Parts Breakdown (Continued) Item Part # Description 52-4039 Outside Harmony Escutcheon With Cylinder Prep 1A 52-4040 Outside Harmony Escutcheon Without Cylinder Prep 52-0796 Outside Weather Gasket 52-0795 Inside Weather Gasket 52-5236 Screw Pack (5A; 5B; 5C; 5D) 82-4355 Trim Pack - Standard levers 79-2162 Trim Pack - Deco levers (shown) 52-4517 H2-IA-02 Controller Assembly 7A 52-5196 Inside Escutcheon w/ Turn Assembly 7B 82-0706 Inside Escutcheon w/out Turn Prep -- Reference Harmony Series Catalog For Available Lever Styles -- Reference Harmony Series Catalog For Available Rose Styles 10 77-4236 12 -- Reference Harmony Series Catalog For Available Lever Styles 13 -- Reference Harmony Series Catalog For Available Cylinders (Size 43) H2-82270-12/24 VDC x Finish w/out Deadbolt, Fail Safe** H2-82271-12/24 VDC x Finish w/out Deadbolt, Fail Secure** H2-82272-12/24 VDC x Finish w/out Deadbolt, Fail Safe, Both Levers Lock** H2-82273-12/24 VDC x Finish w/out Deadbolt, Fail Secure, Both Levers Lock** H2-82274-12/24 VDC x Finish w/out Deadbolt, Fail Safe** H2-82275-12/24 VDC x Finish w/out Deadbolt, Fail Secure** H2-82280-12/24 VDC x Finish w/ Deadbolt, Fail Safe** H2-82281-12/24 VDC x Finish w/ Deadbolt, Fail Secure** H2-82282-12/24 VDC x Finish w/ Deadbolt, Fail Safe, Both Levers Lock** H2-82283-12/24 VDC x Finish” w/ Deadbolt, Fail Secure, Both Levers Lock** H2-82284-12/24 VDC x Finish w/ Deadbolt, Fail Safe** H2-82285-12/24 VDC x Finish w/ Deadbolt, Fail Secure** Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 14* 03/31/17 Req. Mortise screw pack - specify finish (includes: wood & metal lock body screws, faceplate screws & strike screws) † Lock Body 15 82-0579 Electrical Outside Faceplate w/ Deadbolt 15A 82-0578 Electrical Outside Faceplate w/out Deadbolt 16 82-0110 Strike Plate 17 01-2299 #12 X 1 1/4" Phillips Flat Head Wood Screw 21 A7944 Field Prep Template (Not Shown) 22 4590 Door Manufacturer Template (Not Shown) 23 A8027 Installation Instructions (Not Shown) *Patent Pending - www.assaabloydss.com/patents **CAUTION: Not recommended for use on any door used for Life Safety Egress † For End-of-Line Resistor and PHR locks, please consult factory A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock Wiring Diagrams Product 8 PIN CONNECTOR 1-Black 2-Red 3-White 4-Green 5-Orange 4 PIN CONNECTOR 6-Blue 7-Brown 8-Yellow 1-Violet 2-Gray 3-Pink 4-Tan DPS (NC) DPS (COM) ACCESS CONTROL DEVICES: Harmony H2 Mortise, ElectroLynx wire Color / Function assignments SARGENT HARMONY SERIES 12/24VDC (Reader) WIEGAND WIEGAND RX RX EGND LED REF. *DIAGRAMS REF. *DIAGRAMS NEG POS DATA_1 DATA_0 NO/NC COM NEG POS DATA_1 DATA_0 ?? COM H2 Mortise Bored/Exits 12/24 VDC (LOCK RELAY) NEG POS DPS DPS NEG POS NC NC *Diagram on following page If your lock is configured with End of Line Resistors, reference instruction sheet A8191 for the wiring of RX & DPS outputs. Reader LED Configuration The Harmony Series reader can be configured for (3) modes of LED operation. HID Programming cards are also supported to configure the behavior for LED color activity. Call 1-800-810-WIRE for details. PIN 8 (Yellow – LED) PIN 6 (Blue – RX COM) PIN 4 (Green – Data 0) PIN 2 (Red – Reader POS) Mode 1: • Presenting a valid credential causes LED to ‘FLICKER’ green and return to red state. PIN 1 (Black – Reader NEG) PIN 3 (White – Data 1) PIN 5 (Orange – RX NO/NC) PIN 7 (Brown-EGND) Mode 2: • Green LED “ON” when powered. • No Flicker after presenting valid valid credential. PIN 4 (Tan – DPS COM) PIN 2 (Gray – Lock POS) Note: LED wire must be connected to circuit GROUND of the system’s power supply. PIN 1 (Violet – Lock NEG) Mode 3: • PIN 3 (Pink – DPS NC) EAC Panel controls LED operation. Note: Control of LED is a function of the EAC panel equipment (i.e. relay) to toggle between green and red. Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader performance will be impacted. Wire from EAC panel to door must be shielded with drain terminated at EAC panel controller Wire Gauge Charts Total One-Way Length of Wire Run (ft) Load Current @ 12VDC 1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A Total One-Way Length of Wire Run (ft) 1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A 100 20 18 16 14 14 12 12 10 100 24 20 18 18 16 16 14 12 150 18 16 14 12 12 12 10 — 150 22 18 16 16 14 14 12 10 200 16 14 12 12 10 10 — — 200 20 18 16 14 14 12 12 10 250 16 14 12 10 10 10 — — 250 18 16 14 14 12 12 12 10 300 16 12 12 10 10 — — — 300 18 16 14 12 12 12 10 — 400 14 12 10 — — — — — 400 18 14 12 12 10 10 — — 500 14 10 10 — — — — — 500 16 14 12 10 10 — — — 750 12 10 — — — — — — 750 14 12 10 10 — — — — 1,000 10 — — — — — — — 1,000 14 10 10 — — — — — 1,500 10 — — — — — — — 1,500 12 10 — — — — — — A8027G • 800-810-WIRE (9473) • www.sargentlock.com Load Current @ 24VDC Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Red LED ‘ON’ when powered. 03/31/17 • Harmony Series H2 Mortise Lock *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel. Failure to follow proper ESD safe grounding procedures could lead to equipment failure. Typical Harmony Mortise Lock Application Diagram (12/24VDC System) Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473) Reader Electronics Require 12 or 24VDC UL294 Listed Power Supply (or UL603) 12/24VDC System • Reader Draw = 150mA @12 or 24VDC • Actuator Draw = 15mA continuous ck Bla t) (Ho hit This product is polarity sensitive; if the lock does not operate, check the polarity of the input and reverse if necessary. 120 VAC Input Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. d) Gn en Gr Harmony Series H2 Requires 12 or 24VDC UL294 Listed Power Supply (or UL603) 12/24VDC 03/31/17 al) utr (Ne Lock body Power Supply (By Others) Harmony Series H2 UL294 Listed EAC Product READER NEG - Black, 1 (-) READER POS - Red, 2 12 Conductor ElectroLynx Harness From McKinney QC12 Electric Hinge From McKinney (+) DATA 1 - White, 3 12/24VDC DATA 1 DATA 0 - Green, 4 DATA 0 RX (NO/NC) - Orange, 5 RX RX (COM) - Blue, 6 RX *EGND- Brown, 7 LED - Yellow, 8 Not Used Use (NC) for Fail Safe Operation Lock Relay LOCK NEG - Violet, 9 Harmony Series H2 LOCK POS - Gray, 10 DPS (NC) - Pink, 11 DPS (COM) - Tan, 12 Electronic Access Control Panel (By Others) DPS DPS (NO) Fail Secure Operation NOTE: If your lock is configured with End of Line Resistors, reference instruction sheet A8191 for the wiring of RX & DPS outputs. A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock Installation Instructions 1 Door Preparation A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. Left Hand Hinges Left. Open Inward. “LH” Left Hand Reverse Bevel Hinges Left. Open Outward. “LHRB” Right Hand Hinges Right. Open Inward. “RH” Fig. 1A Right Hand Reverse Bevel Hinges Right. Open Outward. “RHRB” B. Door Preparation Prior to installation, make sure all holes are free of burrs, debris, and sharp edges. • If doors are not properly reinforced per ANSI 115.2, commercially available reinforcements should be installed. • Templates: • Field prep: A7944 template ships with product. • Manufacturer: 4590 wood and metal door template. Outside of Door Inside of Door Wood Door Through-bolt Holes (2 places) Raceway for 12 Conductor Network/Power Cable (ElectroLynx) from McKinney Hole for Cable from Reader to Controller Board Raceway for 12 Conductor Network/Power Cable (ElectroLynx) from McKinney Pre-drilled and/or Tapped Holes (2 places) Inside Cylinder Hole Outside Cylinder Hole (70/71, 80/81 functions only) Thumb Turn Hole Lever Handle Hole Lever Handle Hole Mortise Area Pre-drilled and/or Tapped Holes (2 Places) A8027G • 800-810-WIRE (9473) • www.sargentlock.com Fig. 1B 03/31/17 • Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Prepare door according to appropriate template. If necessary, refer to website: www.intelligentopenings.com. Harmony Series H2 Mortise Lock 2 How to Change Hand of Lock body A. Reverse Lock Hand Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A): Right Hand Lock Shown 1. Position lock body with red surface of locking piece visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body. Locking Guide Slot: Red color indicates locked side. 3. Rotate the locking piece 180° until RED surface is on opposite side. Fig. 2A Push In Note: Red indicates locked side (outside). B. Reverse Latch Hand Beveled surface of latch must face strike (Fig. 2B). Triangular Slot The deadlatch is self adjusting. To change hand of latchbolt: 1. Insert screwdriver into the spadeshaped (triangular) slot. Latchbolt 03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 2. Rotate screwdriver 90º to push latch out until back of latch clears lock front; then rotate latch 180º. Latch will then re-enter lock body. Note: Latch cannot be unscrewed. Fig. 2B 3 Configure the DIP Switch Settings IMPORTANT: This product is built and factory tested to the configuration specified. Any change to the 3-position DIP-switch settings located at the bottom of the mortise lock body must be made prior to lock installation. Handing RH & RHR 12 3 LH & LHR Check Polarity: Verify + (red wire) DIP Switch Actuator Operation Fail Safe Fail Secure RX Output Normally Open Normally Closed A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock 4 Install Lock body 1. Wires and connectors go into the mortised area and out of the inside cylinder hole. Inside of Door 2. Insert mortise lock body into mortise door preparation. 3. Carefully feed wires from mortise lock through the non-cylinder side hole of the door preparation. 12 Conductor Network/Power Cable (ElectroLynx) from McKinney 4. Install appropriate hardware lock body screws. NOTE: Do not tighten screws completely at this time. Cylinder should be installed prior to tightening. Feed connectors and wires through non-cylinder side. (2) #12-24 x 1/2” Long Flat Head Philips Screws (Metal Doors) Fig. 4 5 Outside Escutcheon and Mounting Plate Installation NOTE: Feed mortise connectors through the corresponding hole on the mounting plate. 1. Attach the mounting plate using (2) 8-32 x 2" Phillips flat head undercut combo screws in the upper right and middle left positions of the mounting plate and (2) 8-32 x 3/8" Phillips flat head screws in the bottom positions (Fig. 5A). Inside of Door (2) 8-32 x 3/8” Phillips Flat Head Undercut Combo Screw (2) 8-32 x 3/8” Phillips Flat Head Screw Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. (2)#12 x 1-1/4” Long Flat Head Wood Screws (Wood Doors) A8027G • 800-810-WIRE (9473) • www.sargentlock.com 10 03/31/17 Fig. 5A Harmony Series H2 Mortise Lock 5 Outside Escutcheon and Inside Mounting Plate Installation (Continued) 2. Feed the reader cable located on the back of the outside escutcheon through the door prep (Fig. 5B). 3. Outside gasket must be used when installing Harmony in an outdoor application (Fig. 5B). 4. Secure the mounting plate to the outside escutcheon with (2) #8-32 x 2” flat head machine screws (Fig. 5C). Inside of Door Outside of Door Gasket required for exterior door applications Reader Cable 03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 5C Fig. 5B 6 Install Inside Gasket (if necessary) Remember to install inside gasket when lock is being used in an outdoor application. Inside of Door 1. Add gasket (if necessary): Gasket fits snug around plate at top and sides, leaving room for the hole at the bottom. 2. Remove (peel) backing and place gasket on door (Fig. 6). Required for exterior door applications. Fig. 6 11 A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock 7 Outside Cylinder Installation 1. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 8A). 2. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig. 8B). 3. Use the key to rotate the cylinder clockwise until it is flush at the bottom and the SARGENT logo is right-side up. Do not attempt to tighten all the way. 4. Tighten the cylinder clamp set screw to prevent unscrewing of the cylinder (Fig. 8C). 5. Test cylinder function: • 70/71 Function: Key retracts latch. • 80/81 Function: Key retracts latch and projects/retracts deadbolt. • Ensure smooth operation of latchbolt and deadbolt. Correct NOTE: Use lever handle holes to manipulate mortise to ease thread engagement of cylinder. Incorrect Phillips Screwdriver Fig. 8B A8027G • 800-810-WIRE (9473) • www.sargentlock.com Fig. 8C 12 03/31/17 Cylinder Set Screw Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Outside of Door Harmony Series H2 Mortise Lock 8 Outside Lever and Inside Adapter Plate Assembly Installation 1. With outside lever horizontal, insert the mounting post through outside of door and lock body. Make certain the lever spindle is properly engaged inside the lock body (Fig. 9A). 2. On the inside of the door, insert slotted spindle into square hole of mortise lock (Fig. 9B), with spindle slot directed away from the lock body, and aligned with the set screw hole in the inside adapter. 3. Slide inside adapter and plate assembly over spindle and loosely secure with (2) 8-32 X 5/8” Phillips oval head and lock washer machine screws. NOTE: Ensure that position of set screw hole and spinsdle slot are oriented to match location of hole in the inside lever handle. 4. Securely tighten the lock body screws. Inside of Door Mortise Lock body Screws Fig. 9A A8027G • 800-810-WIRE (9473) • www.sargentlock.com 13 Fig. 9B 03/31/17 (2)8-32 X 5/8” Phillips Oval Head and Lock Washer Machine Screws Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Outside of Door Harmony Series H2 Mortise Lock 9 Installing Controller Please follow these steps prior to installing inside escutcheon to prevent any damage caused by pinching wires: Inside of Door 1. Feed controller harness earth ground into and around behind rim of large upper hole of the mounting plate (Fig. 10A, B). Inside of Door P5 Controller PCB Fig. 10B Earth ground J5 J2 Fig. 10A 03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. J1 Connect ElectroLynx® a. Connect P5 (7 Pin Connector) from reader board to J5 on interior escutcheon PCB assembly (Fig. 10C). P5 Fig. 10C b. Connect ElectroLynx harness (4 and 8-pin) from door harness to ElectroLynx harness on interior PCB assembly (Fig. 10A, D). 8-pin ElectroLynx NOTES: Neatly fold the wires into the remaining space to prevent pinching wires when mounting escutcheon. Do not tuck extra mortise lock body wires back inside the lock body cylinder hole. Connectors go on only one way. Do not offset connector and be sure they are completely seated. Fig. 10D PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex) J2 4-pin ElectroLynx J1 1-Violet Lock Neg 3-Pink 1- Black 3-White 5-Orange 7-Brown Actuator (+) Solenoid (-) DPS (NC) PWR NEG DATA 1 RX (NO/NC) EGND 2-Gray Lock Pos 4-Tan 2-Red 4-Green 6-Blue 8-Yellow Actuator (+) Solenoid (-) DPS (COM) PWR POS DATA 0 RX (COM) LED 14 A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock Install Controller Once wires are arranged, position controller at a rotated angle against the door, under earth ground wire. a. Press piece against door while turning clockwise (Fig. 11A). b. Twist into place, perpendicular with door (Fig. 11B). c. Position two-wire green/yellow ground wire ring terminal (from lock body) over hole for top left screw (Fig. 11B, C). d. Position green/yellow reader harness earth ground on top of two-wire ground ring and thread both with (1) 8-32 x 3/8” Phillips flat head undercut combo screw (Fig. 11C, D). IMPORTANT: Note orientation of ground ring terminals in Fig. 11B-D. e. Tighten securely. Inside of Door Fig. 11B Rotate Clockwise Fig. 11A Fig. 11C A8027G • 800-810-WIRE (9473) • www.sargentlock.com 15 03/31/17 Fig. 11D Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. (2) 8-32 x 3/8” Phillips Flat Head Undercut Combo Screw Harmony Series H2 Mortise Lock 12 Connector Attachment (Exterior PCB Assembly) 1. Connect P3 (2-pin connector) from lock body to J3 on module (Fig. 12). 2. Connect P4 (6-pin connector) from lock body to J4 on module (Fig. 12). P3 P4 13 Install Inside Escutcheon Assembly 03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Inside of Door 1. Tighten the inside escutcheon securely to the mounting plate with the Phillips flat head machine screws provided. Use the 8-32 x 5/8” for the top of the escutcheon and the 8-32 x 1/4” screws for the bottom of the escutcheon located under the turn lever (Fig. 13). 8-32 X 5/8” Phillips Flat Head Undercut Machine Screw NOTE: The inside gasket (not shown) must be used when installing Harmony in an outdoor application (refer to previous Step 6). 2. Be sure the turn assembly is functional and the deadbolt functions properly. 8-32 X 1/4” Phillips Flat Head Undercut Machine Screw Fig. 13 16 A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock 14 Inside Rose and Inside Lever Assembly Instructions 1. Rotate the inside rose - first counter clock wise to seat the threads and then, clockwise to securely tighten. Inside of Door 2. Slide lever handle onto spindle until fully seated. Be sure handle is horizontal and facing the hinge side of the door. Push lever onto spindle so minimum gap is visible. 3. Tighten the set screw securely with a 1/8” hex wrench. Spindle 4. Before closing the door, test that lever is functional and ensure smooth operation of the latchbolt and deadbolt. Rose Set Screw 03/31/17 Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 14A Inside Lever Fig. 14B 15 Attach Front Plate 1. Attach front plate with (2) 8-32x1/4” flat head screws and tighten securely. Outside of Door Lock Body Screw (2) 8-32x1/4” Flat Head Screws Fig. 15 Lock Body Screw 17 A8027G • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Mortise Lock Mechanical Operational Check For 82280-82283 & 82270-82273 Function mortise locks with cylinders: 1. Insert key into cylinder and rotate: There should be no friction against lock case, wire harness or any other obstructions. 2. The key will retract the latch: Key should rotate freely. 3. When the deadbolt is thrown: Ensure that the key retracts both the deadbolt and the latch. 4. Inside lever: When used, ensure it retracts both the latch and deadbolt (if provided). 5. Close door: Ensure latch and deadbolt fully extend and do not bind. 10 Electrical Operational Check Note: Once electrical wiring has been successfully completed according to proper application, follow the following steps: 1. Turn power ON. 2. Verify LED located on reader is ON (Red or Green depending on reader configuration (See reader LED Configuration). 3. Present proximity credential and verify LED and sounder activity. Feature Wiegand Test Unit The ASSA ABLOY Wiegand Test Unit verifies your installation in the field. The test unit checks for proper wiring, card reader data integrity, lock functionality including lock/unlock, door position status, and request-to-exit (REX) status. In addition, this tool provides product demonstration abilities to highlight the product’s features and capabilities. A8027G • 800-810-WIRE (9473) • www.sargentlock.com 18 WT1 WT2 12 or 24VDC solenoid lock voltage adjustable Operates as Fail Safe or Fail Secure "Learn" mode allows testing of specific cards without programming at the panel level Card reader data integrity is validated at test unit Works with SE LP10 Displays detailed Wiegand data, including hexadecimal string and total bits received Displays measured endof-line resistor values (if applicable) 03/31/17 5. Verify system operation functions; i.e., present valid Prox credential to reader and unlock door. Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 4. Verify valid card read at EAC panel. SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-727-5477 • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2017, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Sargent Manufacturing Company (New Haven, CT). 2017. Patent pending and/or patent - www.assaabloydss.com/patents. HID, iCLASS, and Edge are trademarks or registered trademarks of HID Global Corporation. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A8027G-06/17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Create Date : 2017:04:24 09:54:51-04:00 Metadata Date : 2017:04:24 10:23:53-04:00 Modify Date : 2017:04:24 10:23:53-04:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:129c0a9d-8f29-4747-95c5-a2382b871490 Original Document ID : adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985 Document ID : xmp.id:d48c1ca4-dcdf-854b-b8f0-99baee861e27 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:0625a9df-af8c-d84e-81d4-3e445a5d13ee Derived From Document ID : xmp.did:aae23e9a-a405-6043-8e5b-186006e65f32 Derived From Original Document ID: adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:04:24 09:54:51-04:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 20 Creator : Adobe InDesign CC 2017 (Windows)EXIF Metadata provided by EXIF.tools