ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15

ASSA ABLOY Inc. Harmony H2 Series Lock FCC Part 15

Contents

Users Manual Bored and Exits

    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-SCYPROX2 IC: 6982A-SCYPROX2  FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210  ACS Report Number:  09-0176 - 15C   Manufacturer: Assa Abloy, Inc. Model: Bored/Exits, Mortise     Manual – Bored/Exits
A8029A06/09Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written  permission of Sargent Manufacturing Company is prohibited. Installation InstructionsHarmony Series H28600, 8800, 8900 Exits
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/091234567                  Table of ContentsWarning  ...................................................................................2General Description .................................................................3Hardware Specifications .........................................................3Electronics Specifications .......................................................3H2 8600 Concealed Vertical Rod (CVR) Exit Device ................4H2 8800 Rim Exit Device ........................................................11H2 8900 Mortise Exit Device ..................................................17Wiring Diagrams ....................................................................24Mechanical Operational Check .............................................28Electrical Operational Check .................................................288910A8029A • 800-810-WIRE (9473) • www.sargentlock.com 2This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi-dential installation.This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the inter-ference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna• Increase the separation between the equipment and receiver• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected• Consult the dealer or an experienced technician for helpThe term “IC:” before the radio certication number only signies that Industry Canada technical specications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)  this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.Warning: Changes or modications to this unit not expressly approved by the party  responsible for compliance could void the user’s authority to operate the equipment.Warning 1Observe precautions for handling electrostatic sensitive devices.!
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 3Electronics SpecificationsGeneral DescriptionThe SARGENT Harmony H2 series exit devices (8600, 8800, 8900) are designed to interface with existing Wiegand  Electronic Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID iCLASS® 13.56MHz technology. The Harmony series technology is backed by SARGENT Grade 1 mechanical hardware. All exits include RX (request to exit) monitoring in the rail and an external Door Position Switch (DPS) for door position monitoring. Harmony is available as 12VDC or 24VDC solenoid operated ET trim. Weatherseal gaskets are also included for exterior door applications. The Harmony H2 iCLASS reader provides visual and audible indicators of lock state (locked/unlocked).Hardware SpecificationsAll Harmony Exit Devices• Certied ANSI/BHMA A156.3 Grade 1• Push bar retracts latch from inside, allowing free egress• Request-to-Exit (REX) Switch activated by pushing rail• Outside lever controlled by any 13.56MHz HID     iCLASS Wiegand credential• Fire rated devices available• UL Listed• Exit devices furnished for 1-3/4” doors• Fail safe or fail secure available• Door Position Switch (DPS, part #3287) supplied to     allow for monitoring• 12VDC/24VDC solenoid-operated ET trim• EAC Panel wiring to door must be shielded with a     drain. Drain terminated at EAC Panel controllerHarmony 8600 Series Concealed Vertical Rod (CVR) • Cylinder override available for 8600 CVR with 106     Series Auxiliary Control• The AFF is 41” for Standard Applications; when a 100    Series Auxiliary Control is used, 38” AFF is     recommended to meet local accessibility standards 12VDC System• Reader Draw = 125mA• 12VDC Solenoid Draw = 500mA• Total Current Draw = 625mA42Wire Gauge ChartsTotal One-Way  Length of  Wire Run (ft)Load Current @ 12VDC1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A100 20 18 16 14 14 12 12 10150 18 16 14 12 12 12 10 —200 16 14 12 12 10 10 — —250 16 14 12 10 10 10 — —300 16 12 12 10 10 — — —400 14 12 10 — — — — —500 14 10 10 — — — — —7501210——————1,000 10 — — — — — — —1,500 10 — — — — — — —Total One-Way  Length of  Wire Run (ft)Load Current @ 24VDC1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A100 24 20 18 18 16 16 14 12150 22 18 16 16 14 14 12 10200 20 18 16 14 14 12 12 10250 18 16 14 14 12 12 12 10300 18 16 14 12 12 12 10 —400 18 14 12 12 10 10 — —500 16 14 12 10 10 — — —750 14 12 10 10 — — — —1,000 14 10 10 — — — — —1,500 12 10 — — — — — —24VDC System• Reader Draw = 125mA• 24VDC Solenoid Draw = 250mA• Total Current Draw = 375mAHarmony 8800 Series Rim• Cylinder override available• Accepts all SARGENT rim cylinders (75/76 functions)• Key retracts latch (75/76 functions)• Latch – 3/4” throw, stainless steelHarmony 8900 Series  Mortise• Cylinder override available• Accepts all     SARGENT mortise     cylinders (75/76 functions)• Key retracts latch     (75/76 functions)• Latch – 3/4” throw,     anti-friction, brass3Harmony Series H2 Exit DevicesWeigand Access Control System3287 Door  Position SwitchHarmony Series H2McKinneyElectronic TransferHinge
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com4122234567891099111213A13B114116151171817Installation Instructions For Harmony Series H2 8600 Concealed Vertical Rod (CVR) Exit Device5Tools Required• Phillips screw driver (standard size)• Flat blade screw driver (standard)Harmony Series H2 8600 ExitsParts Breakdown1010A
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 5ITEM PART #  Description Req.1 68-3577 Chassis Wood Door (WD) Screw Pack  168-3905 Chassis Metal Door (MD) Screw Pack (not shown)2 68-7057 WD 8600 Top Assembly 168-7060 MD/AD 8600 Top Assembly (not shown)3 94-0212 Aux Control Rod Adapter 14 52-4038 Outside Harmony Escutcheon Assembly 15 52-0792 Outside Harmony Gasket 16 52-0793 Inside Harmony Gasket 17 52-5219 Harmony Inside Escutcheon Mounting Plate 18 52-0801 Wire Guide 19 52-5236 Screw Pack (Escutcheon) 110 68-1581 Inside Harmony Escutcheon 110A 52-4036 H2 Controller Assembly 111  *Harmony Trim is Ordered as "N1"N1-773-4 ETL12V Fail Safe 1N1-773-4 ETL 24V Fail SafeN1-774-4 ETL12V Fail SecureN1-774-4 ETL 24V Fail Secure12 52-0263 ET Trim Gasket 113A 68-3859 WD Inner Case Assembly 113B 68-5067 MD/AD Inner Case Assembly 114 68-7241 8600 Chassis LHRB 168-7242 8600 Chassis RHRB (not shown)15 68-0407 Chassis Cover 116 68-3905 Screw Pack (Rail and Chassis Cover) 117 68-0888 MD/WD Bottom Case Assembly 117 68-0037 AD Bottom Case Assembly 118 3287 DPS Door Position Switch (not shown) 119 A8029  Installation Instructions (not shown) 120 4621 MD/AD Door Manufacturer Template (not shown) 121 4622 Wood Door Manufacturer Template (not shown) 1Parts Breakdown For Harmony Series H2 8600 (Continued)Shipment ContentsHarmony Series H2 8600 ExitsHow to Specify ET TrimHow to order without an exit device.Specify: 7 for 700 Series ET, Function, Sufx, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB).Note: Sufx requirements are based on type of device to be used:   •  -8 sufx is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44.   •  -6 sufx is required for all PP, PR, SP, LP, LR and LS devices.   •  -4 sufx is required for all 8400, WD, MD and AD 8600 devices.    •  No sufx is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices         with these functions: 04, 10, 16, 40 and 44.
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com6Step #1 – Prepare DoorA. Verify Hand and Bevel of Door• Check hand of door. Exit Device may be handed.• Door should be tted and hung.• Verify box label for size of exit device, function and hand.B. Door PreparationPrepare door according to appropriate template. If necessary,  refer to website, www.intelligentopenings.com:• Metal door (MD/AD): A7002    - Templates: 4621 and 4445• Wood door (WD): A3937    - Templates: 4622 and 4431       Note: Instruction examples show wood door installation.        For metal/aluminum doors, route cables inside door.#10-24 x 1/2”Left HandReverseLHROutsideInsideRight HandReverseRHR#10-24 x 3/8”Fig. 1AHarmony Series H2 8600 ExitsWood Door ShownFig. 1BStep #2 - Inner Case Assembly InstallationA. Wood Door (WD)Install the inner case assembly with (2) #12 x 1” Phillips athead screw (Fig. 2A).B. Metal Door (MD/AD)1. Assemble rods to inner case.2. Slide rod assembly into door and secure with #10-24 x 3/8”     screw for top inner case assembly and #10-24 x 1/2” screw     for bottom inner case assembly (Fig. 2B).Fig. 2AFig. 2B
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 78600 Installation Instructions (Continued)B. Chassis1. Position chassis carefully onto the inner chassis assembly from the      inside of the door. Be careful not to pinch wire harness.2. Fasten the chassis to door using (4) #12 x 1” Phillips     athead screws (Fig. 3C).Step #3 – Install Outside Exit Trim (ET) and Chassis A. Outside Trim1. For exterior applications, use ET gasket (52-0263)      to seal ET escutcheon and outside door surface (Fig. 3A).2. Route ET wire harness through inner chassis     assembly:    - For wood doors: Route wire harness in cutout.    - For metal doors: Route wire harness through        access hole.3. Mount ET trim to inner chassis assembly using     (2) # 1/2 -20 x 2-3/8” at head machine screws.    ET spindle engages inside the inner chassis     assembly (Fig. 3B).Fig.  3AHarmony Series H2 8600 ExitsFig.  3B#10-24 x 3/8”GasketFig.  3B(4) #12 x 1” PhillipsFlathead Screws Step #4 – Attach Ground Wire and Install Outside Escutcheon and Inside Mounting Plate 1. Connect pin 5 green/yellow ground wire ring terminal      to top right screw  (Fig. 4A and 4B). 2. Secure the mounting plate with (2) #8 x 1/2”      self-tapping screws (Fig. 4A).3. Feed the reader cable connector located      on the back of the outside escutcheon      from the outside of door through door.4. Securely tighten the outside escutcheon with      through-bolts using (2) #8-32 x 2” Phillips at      head screws through the mounting plate. #8-32 X 2”#8-32 X 1/2”Fig.  4AFig.  3CFig.  4BInside of Door
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com8Step #5 – Install GasketAdd Gasket (if necessary):Remember the inside gasket must be used  when installing in an outdoor application. Remove backing and place gasket  on door (Fig. 5A). Inside of DoorGasket required for exterior door applications.Fig.  5AStep #6 – Connect ElectroLynx 1.  Connect P5 (7 Pin Connector) from reader board      to J5 on interior escutcheon PCB assembly (Fig. 6A). 2.  Connect ElectroLynx harness (4 and 8-pin) from door harness       to ElectroLynx harness on interior PCB assembly (Fig. 6A).      NOTES:      Neatly fold the wires onto themselves and into the remaining      space to prevent pinching wires when mounting escutcheon.Do not tuck extra mortise lock body wires back inside the lock    body cylinder hole.      Connectors go on only one way.      Do not offset connector and be sure they are completely seated. Fig.  6A J1 J2To ElectroLynxHarness J5From ReaderBoard P5 to J5PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)J2 J11-Violet Lock DC Neg(Solenoid, neg)3 - Pink NOT USED1- BlackPWR NEG3-WhiteWiegand DATA 15-OrangeRX (N/O)7-Brown EGND2-Gray, Lock DC Pos(Solenoid, pos) 4-Tan NOT USED2-RedPWR POS4-GreenWiegand DATA 06-BlueRX (COM)8-YellowLEDHarmony Series H2 8600 ExitsInside of DoorGasket required for exterior door applications.Fig.  5AFig.  6A J1 J2To ElectroLynxHarness J5From ReaderBoard P5 to J5
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 9Fig.  7AFig.  7BStep #8 – Attach Connectors (Exterior PCB Assembly) 1. Connect P3 (2-pin connector) from lock body      to J3 on module (Fig. 8A). 2. Connect P4 (6-pin connector) from lock body      to J4 on module (Fig. 8A). From Lock Body P3 to J3 From Lock Body P4 to J4Fig.  8A J4 J3Inside of DoorRotate ClockwiseStep #7 – Position Outside WiresPlease follow these steps prior to installing  inside escutcheon to prevent any damage caused by pinching wires:  1.  Once wires are arranged, position piece  at a rotated angle against the door, under earth ground wire. 2.  Press piece against door unwhile turning  clockwise (Fig. 7A). 3.  Twist into place, perpendicular with door (Fig. 7B).Fig.  7AFig.  7BHarmony Series H2 8600 ExitsFrom Lock Body P3 to J3 From Lock Body P4 to J4Fig.  8A J4 J3Inside of DoorRotate Clockwise
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com10Fig.  10AStep #9 – Install Inside Escutcheon1. Position inside gasket and escutcheon against door.      Verify that no wires are being pinched.2. Mount inside escutcheon assembly to plate using      (2) #8-32 x 5/8" Phillips at head undercut      machine screws.    Step #10 – Install Rail Assembly1. Retrieve harness from end of rail. Harness has limited travel      and can be damaged.2. Attach harness to female connector on chassis.3. Install rail and screws per exit device instructions.    Note: This view shows rim exit device version.>> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. <<Fig.  9AInside of DoorHarmony Series H2 8600 Exits(2) #8-32 x 5/8” PhillipsFlat Head Under-cut Machine ScrewsStep #11 - Concealed Door Position Switch Instructions (3287)Use SARGENT 3287 Concealed Door Position Switch with this  Harmony H2 series product: 1. Install the 3287 Concealed Door Position Switch described in SARGENT      document A7448B.2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input.3. Connect the common wire of the switch to the common input terminal of the EAC;      and the normally open wire of the switch to the normally open input      termnial of the EAC.Fig.  11AWiegand Access Control System (Others)McKinneyQC12 Hinge Harmony Series H23287 DoorPosition SwitchLock is 12VDC. Optional 24VDC  lock is available.
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 11Tools Required• Phillips screw driver (standard size)• Flat blade screw driver (standard)Installation Instructions For Harmony Series H2 8800 Rim Exit Device75523410651112131415109199987Left Hand Reverse Door ShownParts BreakdownHarmony Series H2 8800 Exits66A
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com12ITEM PART #  Description Req.1 52-4038 Outside Harmony Escutcheon Assembly 12 52-0792 Outside Weather Gasket 13 52-0793 Inside Weather Gasket 14 52-5219 Harmony Inside Escutcheon Mounting Plate 15 52-5236 Screw Pack (Escutcheon) 16 68-1581 Inside Escutcheon Assembly 16A 52-4036 H2 Controller Assembly 17 68-3905 Screw Pack (Rail and Chassis Cover) 18 68-0406 Chassis Cover 19 68-3922 Screw Pack (Chassis) 110 13-0074 Cylinder Connecting Screws 211 68-7255 8800 Chassis Assembly (Standard)168-7256 8800 Chassis Assembly (12-)68-5836 8800 Chassis Assembly (GL)68-5837 8800  Chassis Assembly (12-, GL)12 13-0086 Cylinder back Plate Used with non-Sargent Cylinders) 113 52-0263 ET Trim Gasket 114                                   *Harmony Trim is Ordered as "N1" 1N1-773-ET 12V Fail Safe Without CylinderN1-773-ET 24V Fail Safe Without CylinderN1-774-ET 12V Fail Secure Without CylinderN1-774-ET 24V Fail Secure Without CylinderN1-775-ET 12V Fail Safe Without CylinderN1-775-ET 24V Fail Safe Without CylinderN1-776-ET 12V Fail Secure Without CylinderN1-776-ET 24V Fail Secure Without Cylinder15 -- Reference Harmony Series Catalog for Available Cylinders 116  3287 DPS Door Position Switch (not shown) 117 A8029 Installation Instructions (not shown) 118 A7883 Field Template (not shown) 119 4615 Manufacturer Template (not shown) 1Parts Breakdown For Harmony Series H2 8800 (Continued)Shipment ContentsHow to Specify ET TrimHow to order without an exit device.Specify: 7 for 700 Series ET, Function, Sufx, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB).Note: Sufx requirements are based on type of device to be used:   •  -8 sufx is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44.   •  -6 sufx is required for all PP, PR, SP, LP, LR and LS devices.   •  -4 sufx is required for all 8400, WD, MD and AD 8600 devices.    •  No sufx is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices         with these functions: 04, 10, 16, 40 and 44. Harmony Series H2 8800 Exits
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 13Step #1 – Door PreparationA. Verify Hand and Bevel of Door• Check hand of door. Exit Device may be handed.• Door should be tted and hung.• Verify box label for size of exit device, function and hand.B. Door PreparationPrepare door according to appropriate template. If necessary,  refer to website, www.intelligentopenings.com:    • Field prep template: A7883    • Manufacturer template: 4615    • Reference exit device templates: 4415, and 4530       Note: Instruction examples show wood door        installation. For metal doors, route cables inside door.Left HandReverseLHROutsideInsideRight HandReverseRHRFig. 1AWood Door ShownFig. 1BFig. 2B DetailFig. 2AWire HarnessET GasketET ControlStep #2 – Outside Trim (Exit Trim, ET) Installation1. For exterior applications, use ET gasket (52-0263) to seal between     ET escutcheon and outside door surface (Fig. 2B).2. Route ET wire harness in cutout for wood doors      and through access hole for metal doors (Fig. 2A).3. Hold ET control onto door.Harmony Series H2 8800 Exits
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com148800 Installation Instructions (Continued)Step #3 – Mounting Chassis1. Position chassis carefully, not to pinch wire harness.2. ET spindle will engage the lower hub of chassis.3. Cylinder tailpiece should engage upper hub of the chassis.4. Though bolt chassis to ET with (2) 1/4 -20 x 2-3/8” at head     machine screws.5. Using (4) #10 wood screws or #10-24 machine screws fasten     chassis to door.Step #4 – Cylinder Installation1. Position cylinder in ET control.2. For non-Sargent cylinder ONLY:     Secure cylinder with cylinder      backplate using      (2) #12-24 x 1-7/8” screws. 3. Make sure ET harness is clear of     cylinder and cylinder tailpiece.#12 x 1” Phillips Flat Head Wood Screw1/4 -20 x 2-3/8” FlatHead Machine ScrewExit ChassisInside of Door#12-24 X 1-7/8” ScrewsCylinderInside of DoorStep #5 – Outside Escutcheon and Inside Mounting Plate and Ground Wire Installation1. Connect pin 5 green/yellow ground wire ring terminal to      top right screw  (Fig. 5A and 5B). 1. Secure the mounting plate with (2) self-tapping screws (#8 x 1/2”).2. Feed the reader cable connector located on the back of the outside     escutcheon from the outside of door through door.3. Securely tighten the outside escutcheon with (2) through-bolts     (#8-32 x 2”) Phillips at head screws through the mounting plate.Outside Gasket#8-32 x 2” Phillips Flat Head Screws#8 x 1/2” Self-Taping ScrewsFig. 3AFig. 4AFig. 5AInside of DoorHarmony Series H2 8800 ExitsFig. 5B
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 15Please follow these steps prior to installing inside escutcheon  assembly to prevent any damage caused by pinching wires: 1. Align the ElectroLynx® connectors (8 and 4-pin) to one side of      the wire guide inside of the door prep. The reader connections      and excess wire are arranged on the other.2. Connect the ElectroLynx® connectors (8 and 4-pin) and     establish their position inside of the door prep on     the proper side of the wire guide (Fig. 8A).3. Neatly route the remaining wires onto themselves and into     the remaining space to prevent pinching wires when      mounting the escutcheon (Fig. 8B).Step #8 – Outside Escutcheon and Wire Positioning Step #6 – Install GasketAdd Gasket (if necessary):Remember the inside gasket must be used  when installing in an outdoor application. Remove backing and place gasket  on door (Fig. 6A). Inside of DoorOutside of DoorFig. 8A Fig. 8BFig.  6AStep #7 – Connect ElectroLynx 1.  Connect P5 (7 Pin Connector) from reader board      to J5 on interior escutcheon PCB assembly (Fig. 7A). 2.  Connect ElectroLynx harness (4 and 8-pin) from door harness       to ElectroLynx harness on interior PCB assembly (Fig. 7A).      NOTES:      Neatly fold the wires onto themselves and into the remaining      space to prevent pinching wires when mounting escutcheon.Do not tuck extra mortise lock body wires back inside the lock    body cylinder hole.      Connectors go on only one way.      Do not offset connector and be sure they are completely seated. Fig.  7A J1 J2To ElectroLynxHarness J5From ReaderBoard P5 to J5Harmony Series H2 8800 ExitsPCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)J2 J11-Violet Lock DC Neg(Solenoid, neg)3 - Pink NOT USED1- BlackPWR NEG3-WhiteWiegand DATA 15-OrangeRX (N/O)7-Brown EGND2-Gray, Lock DC Pos(Solenoid, pos) 4-Tan NOT USED2-RedPWR POS4-GreenWiegand DATA 06-BlueRX (COM)8-YellowLEDRotate ClockwiseGasket required for exterior door applications.
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com16Step #10 – Installation of Inside Escutcheon1. Position inside gasket and escutcheon against door. Verify that no     wires are being pinched.2. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8"     Phillips at head undercut machine screws. (2) #8-32 x 5/8” PhillipsFlat Head Under-cut Machine ScrewsFig.  10AInside of DoorHarmony Series H2 8800 ExitsFrom Lock Body P3 to J3 From Lock Body P4 to J4Fig.  9A J4 J3Step #9 – Connector Attachment (Exterior PCB Assembly) 1. Connect P3 (2-pin connector) from lock body      to J3 on module (Fig. 9A). 2. Connect P4 (6-pin connector) from lock body      to J4 on module (Fig. 9A).
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 17Step #11 – Installation of Rail Assembly1. Retrieve harness from end of rail. Harness has limited travel       and can be damaged.2. Attach harness to female connector on chassis.3. Install rail and screws per exit device instructions.    Note: This view shows rim exit device version>> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. <<Step #12 - Concealed Door Position Switch (3287) InstructionsUse SARGENT 3287 Concealed Door Position Switch with this  Harmony H2 series product: 1. Install the 3287 Concealed Door Position Switch described in SARGENT      document A7448B.2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input.3. Connect the common wire of the switch to the common input terminal of the EAC;      and the normally open wire of the switch to the normally open input      termnial of the EAC.Fig.  11AFig.  12AWiegand Access Control System (Others)McKinneyQC12 Hinge Harmony Series H23287 DoorPosition SwitchLock is 12VDC. Optional 24VDC  lock is available.
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com18Tools Required• Phillips screw driver (standard size)• Flat blade screw driver (standard)Installation Instructions For Harmony Series H2 8900 Mortise Exit Device8Left Hand Reverse Door ShownParts Breakdown123456578910111213 14161566AHarmony Series H2 8900 Exits
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 19Parts Breakdown For Harmony Series H2 8900 (Continued)ITEM PART #  Description Req.1 52-4038 Outside Harmony Escutcheon Assembly 12 52-0792 Outside Harmony Gasket 13 52-0793 Inside Harmony Gasket 14 52-5219 Harmony Inside Escutcheon Mounting Plate   15 52-5236 Screw Pack (Escutcheon) 16 68-1581 Inside Harmony Escutcheon Assembly 16A 52-4036 H2 Controller Assembly 17 68-3905 Screw Pack (Rail and Chassis Cover) 18 68-0407 Chassis Cover 19 68-3922 Screw Pack (Chassis) 110 68-7253 8900 Chassis Assembly LHRB 168-5754 8900 Chassis Assembly RHRB 111 52-0263 ET Trim Gasket 112                                  *Harmony Trim is Ordered as "N1"N1-773-ET 12V Fail Safe Without Cylinder 1N1-773-ET 24V Fail Safe Without CylinderN1-774-ET 12V Fail Secure Without CylinderN1-774-ET 24V Fail Secure Without CylinderN1-773-ET 12V Fail Safe With CylinderN1-773-ET 24V Fail Safe With CylinderN1-774-ET 12V Fail Secure With CylinderN1-774-ET 24V Fail Secure With Cylinder13 -- Reference Harmony Series Catalog for Available Cylinders 114 915 8900 Lock Body Assembly LHRB 1915 8900 Lock Body Assembly RHRB15 99-2628 Screw Pack (Mortise Lock) 116 99-0131TAB Strike Pack (Specify Bevel and Lip Length) 117 A8029 Instruction Sheet (not shown) 118 A7948 Field Prep Template (not shown) 119 4613 Manufacturer Template (not shown) 1Shipment ContentsHow to Specify ET TrimHow to order without an exit device.Specify: 7 for 700 Series ET, Function, Sufx, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB).Note: Sufx requirements are based on type of device to be used:   •  -8 sufx is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44.   •  -6 sufx is required for all PP, PR, SP, LP, LR and LS devices.   •  -4 sufx is required for all 8400, WD, MD and AD 8600 devices.    •  No sufx is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices         with these functions: 04, 10, 16, 40 and 44. Harmony Series H2 8900 Exits
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com20Step #1 – Door PreparationA. Verify Hand and Bevel of Door• Check hand of door. Exit Device may be handed.• Door should be tted and hung.• Verify box label for size of exit device, function and hand.B. Door PreparationPrepare door according to appropriate template. If necessary,  refer to website, www.intelligentopenings.com:    • Field prep template: A7948 (ships with product)    • Door manufacturer templates: 4613, 4290, and 4314.         Note: Instruction examples show wood door installation.        For metal doors, route cables inside door.Left HandReverseLHROutsideInsideRight HandReverseRHRFig. 1AWood Door ShownFig. 1BFig. 2B DetailFig. 2AMortiseWire(2) Flat Head Wood ScrewsStep #2 – Mortise Lock and Outside Exit Trim (ET) Installation1. Slide mortise lock into pocket and securely fasten with (2) at head screws (Fig. 2A).2. Route “ET” harness through wire cutout on inside of door.3. For exterior applications, use gasket (52-0263)     to seal between ET escutcheon and      outside door surface (Fig. 2B Detail).4. Place ET control on door with spindle      engaging the mortise lock.ETETGasketHarmony Series H2 8900 Exits
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 218900 Installation Instructions (Continued)Step #3 – Cylinder InstallationFor devices without cylinders, skip this section.1. Back cylinder set screw out slightly (Fig. 3A).2. Insert cylinder through “ET” control and thread into     mortise lock until cylinder is ush with “ET”.    Keyway must be vertical and SARGENT    Position Sargent Logo at top of cylinder (Fig. 3B).3. Tighten cylinder set screw.Step #4 – Chassis to Door Installation1. Route ET wire harness along track cutout for wood doors     and access hole for metal doors (Fig. 4A).2. Temporarily attach chassis to rail, then lock push rail down     using hex or cylinder key or by holding push rail in the      depressed position on 8900 exit device (Fig. 4B).3. Position chassis and rail on door so that lever     arm is under rear section of mortise lock lever     then lift up until latch bolt is completely     retracted. With chassis in this position and     rail horizontal, mark location of chassis     mounting holes (Fig. 4C). Drill holes for screws.4. Release push rail and disassemble chassis     from rail. Mount chassis on door.    Do not pinch harness wires.5. Fasten exit chassis to door using     (4) #10 wood screws or #10-24 x 3/4”     machine screws.6. Using (2) 1/4-20 x 2-3/8” at head screws,      attach “ET” to chassis.Cylinder Set ScrewET ControlInside of DoorElectroLynx Connectors(4) #10 Wood Screwsor #10-24 Machine ScrewsFig. 3ACylinderCorrect                      IncorrectSARGENTSARGENTFig. 3B DetailWire Harness(2) 1/4-20 x 2-3/8” FlatHead Machine Screws (to secure ET)Fig. 4B Fig. 4CExit ChassisFig. 4ADepress arm into rail openingand slide rail onto chassis.Push RailChassisRail AssemblyLock Down ScrewAttach to chassis with (2) #8-32 x 3/8” Phillips Truss Head Machine ScrewsLatchboltLeverLever ArmChassisHarmony Series H2 8900 Exits
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com22Step #5 – Outside Escutcheon and Inside Mounting Plate and Ground Wire Installation1. Connect pin 5 green/yellow ground wire ring terminal to      top right screw  (Fig. 5A and 5B). 1. Secure the mounting plate with (2) self-tapping screws (#8 x 1/2”).2. Feed the reader cable connector located on the back of the outside     escutcheon from the outside of door through door.3. Securely tighten the outside escutcheon with (2) through-bolts     (#8-32 x 2”) Phillips at head screws through the mounting plate.Outside Gasket#8-32 x 2” Phillips Flat Head Screws#8 x 1/2” Self-Taping ScrewsFig. 5AInside of DoorFig. 5BStep #6 – Install GasketAdd Gasket (if necessary):Remember the inside gasket must be used when installing in an  outdoor application. Remove backing and place gasket on door (Fig. 6A). Inside of DoorFig.  6APCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)J2 J11-Violet Lock DC Neg(Solenoid, neg)3 - Pink NOT USED1- BlackPWR GND3-WhiteWiegand DATA 15-OrangeRX (N/O)7-Brown EGND2-Gray, Lock DC Pos(Solenoid, pos) 4-Tan NOT USED2-RedPWR POS4-GreenWiegand DATA 06-BlueRX (COM)8-YellowLEDGasket required for exterior door applications.Harmony Series H2 8900 ExitsFig.  7A J1 J2To ElectroLynxHarness J5From ReaderBoard P5 to J5Step #7 – Connect ElectroLynx 1.  Connect P5 (7 Pin Connector) from reader board      to J5 on interior escutcheon PCB assembly (Fig. 7A). 2.  Connect ElectroLynx harness (4 and 8-pin) from door harness       to ElectroLynx harness on interior PCB assembly (Fig. 7A).      NOTES:      Neatly fold the wires onto themselves and into the remaining      space to prevent pinching wires when mounting escutcheon.Do not tuck extra mortise lock body wires back inside the lock    body cylinder hole.      Connectors go on only one way.      Do not offset connector and be sure they are completely seated.
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 23Please follow these steps prior to installing inside escutcheon  assembly to prevent any damage caused by pinching wires: 1. Align the ElectroLynx® connectors (8 and 4-pin) to one side      of the wire guide inside of the door prep. The reader      connections and excess wire are arranged on the other.2. Connect the ElectroLynx® connectors (8 and 4-pin) and     establish their position inside of the door prep on     the proper side of the wire guide (Fig. 8A).3. Neatly route the remaining wires onto themselves and into     the remaining space to prevent pinching wires when      mounting the escutcheon (Fig.8B).Step #8 – Outside Escutcheon and Wire Positioning Outside of DoorHarmony Series H2 8900 ExitsFig. 8A Fig. 8BRotate ClockwiseFrom Lock Body P3 to J3 From Lock Body P4 to J4Fig.  9A J4 J3Step #9 – Connector Attachment (Exterior PCB Assembly) 1. Connect P3 (2-pin connector) from lock body      to J3 on module (Fig. 9A). 2. Connect P4 (6-pin connector) from lock body      to J4 on module (Fig. 9A).
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com24Fig.  11AStep #11 – Installation of Rail Assembly1. Retrieve harness from end of rail. Harness has limited travel       and can be damaged.2. Attach harness to female connector on chassis.3. Install rail and screws per exit device instructions.    Note: This view shows rim exit device version>> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. <<Step #10 – Installation of Inside Escutcheon1. Position inside gasket and escutcheon against door. Verify that no     wires are being pinched.2. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8"     Phillips at head undercut machine screws.(2) #8-32 x 5/8” PhillipsFlat Head Under-cut Machine ScrewsFig.  10AInside of DoorStep #12 - Concealed Door Position Switch (3287) InstructionsUse SARGENT 3287 Concealed Door Position Switch with this  Harmony H2 series product: 1. Install the 3287 Concealed Door Position Switch described in SARGENT      document A7448B.2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input.3. Connect the common wire of the switch to the common input terminal of the EAC;      and the normally open wire of the switch to the normally open input      termnial of the EAC.Harmony Series H2 8900 ExitsFig.  12AWiegand Access Control System (Others)McKinneyQC12 Hinge Harmony Series H23287 DoorPosition SwitchLock is 12VDC. Optional 24VDC  lock is available.
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 25Product 8 PIN CONNECTOR 4 PIN CONNECTOR1-Black 2-Red 3-White 4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 9-Violet 10-Gray 11-Pink 12-TanACCESS CONTROL DEVICES: Harmony H2 Exits, ElectroLynx wire Color / Function assignments12/24VDC (Reader)WIE-GANDWIE-GANDRX RX EGND LED 12 OR 24 VDC(LOCK RELAY)DPS (NC)DPS (COM)SARGENT -HARMONY SERIES,H2 ExitsNEG POS DATA_1 DATA_0 NO  COM EGND REF.*DIA-GRAMSNEG POS N/A N/AWiring Diagrams8Reader LED ConfigurationThe Harmony Series reader can be congured for (3) modes of LED operation.  HID Programming cards are supported to congure the behavior for LED  color activity. Call 1-800-WIRE for details. Mode 1:• Red LED ‘ON’ when powered.• Presenting a 13.56MHz credential causes LED to ‘FLICKER’     green and return to red state.• Reference *Diagram #1 as a function of power      requirement (12VDC or 24VDC).   Note: LED wire is unconnected.Mode 2:• Green LED “ON” when powered.• No Flicker after presenting valid 13.56MHz credential.• Reference *Diagram #2 as a function of power     requirement (12VDC or 24VDC).   Note: LED wire must be connected to circuit GROUND of the     system’s power supply. Mode 3:• EAC Panel controls LED operation.• Reference *Diagram #3 as a function of power requirement (12VDC or 24VDC).   Note: Control of LED is a function of the EAC panel equipment (ie. relay) to toggle between green and red.   Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader     performance will be interfered (*Diagram #3).*Diagrams on following pagesPIN 8 (Yellow – LED)PIN 6 (Blue – RX COM)PIN 4 (Green – Data 0)PIN 2 (Red – Reader POS)PIN 1 (Black – Reader NEG)PIN 3 (White – Data 1)PIN 5 (Orange – RX N/O)PIN 7 (Brown)PIN 4 (Not Used) PIN 2 (Gray – Lock POS)PIN 1 (Violet – Lock NEG)PIN 3  (Not Used)Harmony Series H2 Exit Devices
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com26Typical Harmony Exit Application Diagram (12/24VDC Lock)DIAGRAM #1 – MODE 1: RED LED ‘ON’ WHEN POWERED12/24VDC SYSTEM• Reader Draw = 125mA• 12VDC Solenoid Draw = 500mA• 12VDC Total Current Draw = 625mA• 24VDC Solenoid Draw = 250mA• 24VDC Total Current Draw = 375mAPower Supply(By Others)Electronic Access Control Panel (By Others)Lock Relay(NO) Fail Secure OperationDPS DPSDATA 1DATA 0RX (NO Option)RX (COM)READER NEG - Black, 1READER POS - Red, 2DATA 1 - White, 3DATA 0 - Green, 4RX (NO) - Orange, 5RX (COM) - Blue, 6*EGND - Brown, 7LED - Yellow, 8LOCK NEG - Violet, 9LOCK POS - Gray, 10Not Used H2 Harmony Exit3287 DoorPosition Switch12/24VDCH    N    G-    +120 VACInputBlack (Hot)    White (Neutral)         Green (Gnd)White (C)Green (NC)Harmony Series H2Requires 12 or 24 VDCUse (NC) for FailSafe OperationHarmony Series H2 Exit Devices*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.  Failure to follow proper ESD safe grounding procedures could lead to equipment failure. QC12 Electric HingeFrom McKinney12 ConductorElectroLynx HarnessFrom McKinney
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.A8029A • 800-810-WIRE (9473) • www.sargentlock.com 27Typical Harmony Exit Application Diagram (12/24VDC Lock)DIAGRAM #2 – MODE 2: GREEN LED ‘ON’ WHEN POWEREDPower Supply(By Others)Electronic Access Control Panel (By Others)Lock Relay(NO) Fail Secure OperationDPS DPSDATA 1DATA 0RX (NO Option)RX (COM)READER NEG - Black, 1READER POS - Red, 2DATA 1 - White, 3DATA 0 - Green, 4RX (NO) - Orange, 5RX (COM) - Blue, 6*EGND - Brown, 7LED - Yellow, 8LOCK NEG - Violet, 9LOCK POS - Gray, 10DPS (NC) - Pink, 11DPS (COM) - Tan, 123287 DoorPosition Switch12/24VDCH    N    G-    +120 VACInputBlack (Hot)    White (Neutral)         Green (Gnd)White (C)Green (NC)Use (NC) for FailSafe Operation12/24VDC SYSTEM• Reader Draw = 125mA• 12VDC Solenoid Draw = 500mA• 12VDC Total Current Draw = 625mA• 24VDC Solenoid Draw = 250mA• 24VDC Total Current Draw = 375mAHarmony Series H2Requires 12 or 24 VDCH2 Harmony ExitHarmony Series H2 Exit Devices*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.  Failure to follow proper ESD safe grounding procedures could lead to equipment failure. 12 ConductorElectroLynx HarnessFrom McKinneyQC12 Electric HingeFrom McKinney
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09A8029A • 800-810-WIRE (9473) • www.sargentlock.com28Harmony Series H2 Exit DevicesTypical Harmony Exit Application Diagram (12/24VDC Lock)DIAGRAM #3 – MODE 3: EAC PANEL CONFIGURABLEPower Supply(By Others)Electronic Access Control Panel (By Others)Use (NC) for FailSafe OperationLock Relay(NO) Fail Secure OperationDPS DPSDATA 1DATA 0RX (NO Option)RX (COM)LEDREADER NEG - Black, 1READER POS - Red, 2DATA 1 - White, 3DATA 0 - Green, 4RX (NO) - Orange, 5RX (COM) - Blue, 6*EGND - Brown, 7LED - Yellow, 8LOCK NEG - Violet, 9LOCK POS - Gray, 10H2 Harmony Exit3287 DoorPosition Switch12/24DCH    N    G-    +120 VACInputBlack (Hot)    White (Neutral)         Green (Gnd)White (C)Green (NC)12/24VDC SYSTEM• Reader Draw = 125mA• 12VDC Solenoid Draw = 500mA• 12VDC Total Current Draw = 625mA• 24VDC Solenoid Draw = 250mA• 24VDC Total Current Draw = 375mAHarmony Series H2Requires 12 or 24 VDC*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.  Failure to follow proper ESD safe grounding procedures could lead to equipment failure. 12 ConductorElectroLynx HarnessFrom McKinneyQC12 Electric HingeFrom McKinney
A8029A-06/30/09SARGENT100 Sargent DriveNew Haven, CT 06511 USA800-481-8464 •  www.sargentlock.comFounded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience.For devices without cylinders, go to step 3.1. For devices with cylinders, insert key into cylinder and rotate.2. The key will retract the latch and rods, the key should rotate freely.3. Depress inside rail to retract latch and rods.Mechanical Operational CheckNote: Once electrical wiring has been successfully completed according to proper application, follow the following step:1. Turn power ON.2. Verify LED located on reader is ON - red or green,     depending on reader conguration (see reader      LED conguration). 3. Present credential and verify LED and      sounder activity.4. Verify valid card read at EAC Panel. 5. Verify system operation functions; i.e., when      credential is presented to reader that the      door unlocks. Electrical Operational Check11.10