ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15
ASSA ABLOY Inc. Harmony H2 Series Lock FCC Part 15
ASSALOY >
Contents
- 1. Users Manual Bored and Exits
- 2. Users Manual Mortise
Users Manual Bored and Exits
Certification Exhibit FCC ID: U4A-SCYPROX2 IC: 6982A-SCYPROX2 FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210 ACS Report Number: 09-0176 - 15C Manufacturer: Assa Abloy, Inc. Model: Bored/Exits, Mortise Manual – Bored/Exits 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Installation Instructions Harmony Series H2 8600, 8800, 8900 Exits A8029A 06/09 Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Table of Contents 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Warning . ..................................................................................2 General Description..................................................................3 Hardware Specifications..........................................................3 Electronics Specifications........................................................3 H2 8600 Concealed Vertical Rod (CVR) Exit Device.................4 H2 8800 Rim Exit Device.........................................................11 H2 8900 Mortise Exit Device...................................................17 Wiring Diagrams.....................................................................24 Mechanical Operational Check..............................................28 10 Electrical Operational Check..................................................28 Warning Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced technician for help The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. Observe precautions for handling electrostatic sensitive devices. A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Exit Devices General Description The SARGENT Harmony H2 series exit devices (8600, 8800, 8900) are designed to interface with existing Wiegand Electronic Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID iCLASS® 13.56MHz technology. The Harmony series technology is backed by SARGENT Grade 1 mechanical hardware. All exits include RX (request to exit) monitoring in the rail and an external Door Position Switch (DPS) for door position monitoring. Harmony is available as 12VDC or 24VDC solenoid operated ET trim. Weatherseal gaskets are also included for exterior door applications. The Harmony H2 iCLASS reader provides visual and audible indicators of lock state (locked/unlocked). Hardware Specifications All Harmony Exit Devices Harmony 8800 Series Rim • Certified ANSI/BHMA A156.3 Grade 1 • Cylinder override available • Push bar retracts latch from inside, allowing free egress • Accepts all SARGENT rim cylinders (75/76 functions) • Request-to-Exit (REX) Switch activated by pushing rail • Key retracts latch (75/76 functions) • Outside lever controlled by any 13.56MHz HID iCLASS Wiegand credential • Latch – 3/4” throw, stainless steel • Fire rated devices available Harmony 8900 Series Mortise • UL Listed • Cylinder override available • Exit devices furnished for 1-3/4” doors • Accepts all SARGENT mortise cylinders (75/76 functions) • Fail safe or fail secure available • Door Position Switch (DPS, part #3287) supplied to allow for monitoring Weigand Access Control System • Key retracts latch (75/76 functions) • 12VDC/24VDC solenoid-operated ET trim • Latch – 3/4” throw, anti-friction, brass • EAC Panel wiring to door must be shielded with a drain. Drain terminated at EAC Panel controller 3287 Door Position Switch McKinney Electronic Transfer Hinge • The AFF is 41” for Standard Applications; when a 100 Series Auxiliary Control is used, 38” AFF is recommended to meet local accessibility standards Harmony Series H2 Electronics Specifications 12VDC System 24VDC System • Reader Draw = 125mA • Reader Draw = 125mA • 12VDC Solenoid Draw = 500mA • 24VDC Solenoid Draw = 250mA • Total Current Draw = 625mA • Total Current Draw = 375mA Wire Gauge Charts Total One-Way Length of Wire Run (ft) Load Current @ 12VDC 1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A Total One-Way Length of Wire Run (ft) Load Current @ 24VDC 1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A 100 20 18 16 14 14 12 12 10 100 24 20 18 18 16 16 14 12 150 18 16 14 12 12 12 10 — 150 22 18 16 16 14 14 12 10 200 16 14 12 12 10 10 — — 200 20 18 16 14 14 12 12 10 250 16 14 12 10 10 10 — — 250 18 16 14 14 12 12 12 10 300 16 12 12 10 10 — — — 300 18 16 14 12 12 12 10 — 400 14 12 10 — — — — — 400 18 14 12 12 10 10 — — 500 14 10 10 — — — — — 500 16 14 12 10 10 — — — 750 12 10 — — — — — — 750 14 12 10 10 — — — — 1,000 10 — — — — — — — 1,000 14 10 10 — — — — — 1,500 10 — — — — — — — 1,500 12 10 — — — — — — A8029A • 800-810-WIRE (9473) • www.sargentlock.com 06/30/09 • Cylinder override available for 8600 CVR with 106 Series Auxiliary Control Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Harmony 8600 Series Concealed Vertical Rod (CVR) Harmony Series H2 8600 Exits Installation Instructions For Harmony Series H2 8600 Concealed Vertical Rod (CVR) Exit Device Parts Breakdown Tools Required • Phillips screw driver (standard size) • Flat blade screw driver (standard) 10 10A 10 16 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 15 11 14 13B 13A 12 17 17 18 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8600 Exits Parts Breakdown For Harmony Series H2 8600 (Continued) Shipment Contents ITEM PART # Description 68-3577 Chassis Wood Door (WD) Screw Pack 68-3905 Chassis Metal Door (MD) Screw Pack (not shown) 68-7057 WD 8600 Top Assembly 68-7060 MD/AD 8600 Top Assembly (not shown) 94-0212 Aux Control Rod Adapter 52-4038 Outside Harmony Escutcheon Assembly 52-0792 Outside Harmony Gasket 52-0793 Inside Harmony Gasket 52-5219 Harmony Inside Escutcheon Mounting Plate 52-0801 Wire Guide 52-5236 Screw Pack (Escutcheon) 10 68-1581 Inside Harmony Escutcheon 10A 52-4036 H2 Controller Assembly 11 *Harmony Trim is Ordered as "N1" Req. N1-773-4 ETL12V Fail Safe N1-773-4 ETL 24V Fail Safe N1-774-4 ETL12V Fail Secure ET Trim Gasket 13A 68-3859 WD Inner Case Assembly 13B 68-5067 MD/AD Inner Case Assembly 14 68-7241 8600 Chassis LHRB 68-7242 8600 Chassis RHRB (not shown) 15 68-0407 Chassis Cover 16 68-3905 Screw Pack (Rail and Chassis Cover) 17 68-0888 MD/WD Bottom Case Assembly 17 68-0037 AD Bottom Case Assembly 18 3287 DPS Door Position Switch (not shown) 19 A8029 Installation Instructions (not shown) 20 4621 MD/AD Door Manufacturer Template (not shown) 21 4622 Wood Door Manufacturer Template (not shown) How to Specify ET Trim How to order without an exit device. Specify: 7 for 700 Series ET, Function, Suffix, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB). Note: Suffix requirements are based on type of device to be used: • -8 suffix is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44. • -6 suffix is required for all PP, PR, SP, LP, LR and LS devices. • -4 suffix is required for all 8400, WD, MD and AD 8600 devices. • No suffix is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices with these functions: 04, 10, 16, 40 and 44. A8029A • 800-810-WIRE (9473) • www.sargentlock.com 06/30/09 52-0263 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. N1-774-4 ETL 24V Fail Secure 12 Harmony Series H2 8600 Exits Step #1 – Prepare Door Inside A. Verify Hand and Bevel of Door • Check hand of door. Exit Device may be handed. • Door should be fitted and hung. • Verify box label for size of exit device, function and hand. Left Hand Reverse LHR Right Hand Reverse RHR Outside Fig. 1A B. Door Preparation Wood Door Shown Prepare door according to appropriate template. If necessary, refer to website, www.intelligentopenings.com: • Metal door (MD/AD): A7002 - Templates: 4621 and 4445 • Wood door (WD): A3937 - Templates: 4622 and 4431 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Note: Instruction examples show wood door installation. For metal/aluminum doors, route cables inside door. Fig. 1B Step #2 - Inner Case Assembly Installation A. Wood Door (WD) Install the inner case assembly with (2) #12 x 1” Phillips flathead screw (Fig. 2A). B. Metal Door (MD/AD) 1. Assemble rods to inner case. 2. Slide rod assembly into door and secure with #10-24 x 3/8” screw for top inner case assembly and #10-24 x 1/2” screw for bottom inner case assembly (Fig. 2B). #10-24 x 3/8” #10-24 x 1/2” Fig. 2A Fig. 2B A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8600 Exits 8600 Installation Instructions (Continued) Step #3 – Install Outside Exit Trim (ET) and Chassis A. Outside Trim 1. For exterior applications, use ET gasket (52-0263) to seal ET escutcheon and outside door surface (Fig. 3A). 2. Route ET wire harness through inner chassis assembly: - For wood doors: Route wire harness in cutout. - For metal doors: Route wire harness through access hole. Gasket #10-24 x 3/8” 3. Mount ET trim to inner chassis assembly using (2) # 1/2 -20 x 2-3/8” flat head machine screws. ET spindle engages inside the inner chassis assembly (Fig. 3B). Fig. 3A Fig. 3B B. Chassis 1. Position chassis carefully onto the inner chassis assembly from the inside of the door. Be careful not to pinch wire harness. Step #4 – Attach Ground Wire and Install Outside Escutcheon and Inside Mounting Plate 1. Connect pin 5 green/yellow ground wire ring terminal to top right screw (Fig. 4A and 4B). 2. Secure the mounting plate with (2) #8 x 1/2” self-tapping screws (Fig. 4A). Fig. 3B 3. Feed the reader cable connector located on the back of the outside escutcheon from the outside of door through door. #8-32 X 1/2” 4. Securely tighten the outside escutcheon with through-bolts using (2) #8-32 x 2” Phillips flat head screws through the mounting plate. #8-32 X 2” Fig. 4A Inside of Door Fig. 4B A8029A • 800-810-WIRE (9473) • www.sargentlock.com 06/30/09 Fig. 3C Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. (4) #12 x 1” Phillips Flathead Screws 2. Fasten the chassis to door using (4) #12 x 1” Phillips flathead screws (Fig. 3C). Harmony Series H2 8600 Exits Step #5 – Install Gasket Add Gasket (if necessary): Remember the inside gasket must be used when installing in an outdoor application. Inside of Door Remove backing and place gasket on door (Fig. 5A). Gasket required for exterior door applications. Fig. 5A Step #6 – Connect ElectroLynx 1. Connect P5 (7 Pin Connector) from reader board to J5 on interior escutcheon PCB assembly (Fig. 6A). 2. Connect ElectroLynx harness (4 and 8-pin) from door harness to ElectroLynx harness on interior PCB assembly (Fig. 6A). From Reader Board P5 to J5 J5 NOTES: J1 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Neatly fold the wires onto themselves and into the remaining space to prevent pinching wires when mounting escutcheon. To ElectroLynx Harness Do not tuck extra mortise lock body wires back inside the lock body cylinder hole. J2 Connectors go on only one way. Fig. 6A Do not offset connector and be sure they are completely seated. PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex) J2 J1 1-Violet Lock DC Neg 3 - Pink 1- Black 3-White 5-Orange 7-Brown (Solenoid, neg) NOT USED PWR NEG Wiegand DATA 1 RX (N/O) EGND 2-Gray, Lock DC Pos 4-Tan 2-Red 4-Green 6-Blue 8-Yellow (Solenoid, pos) NOT USED PWR POS Wiegand DATA 0 RX (COM) LED A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8600 Exits Step #7 – Position Outside Wires Inside of Door Please follow these steps prior to installing inside escutcheon to prevent any damage caused by pinching wires: 1. Once wires are arranged, position piece at a rotated angle against the door, under earth ground wire. 2. Press piece against door unwhile turning clockwise (Fig. 7A). 3. Twist into place, perpendicular with door (Fig. 7B). Rotate Clockwise Fig. 7B 1. Connect P3 (2-pin connector) from lock body to J3 on module (Fig. 8A). 2. Connect P4 (6-pin connector) from lock body to J4 on module (Fig. 8A). From Lock Body P3 to J3 J3 J4 Fig. 8A A8029A • 800-810-WIRE (9473) • www.sargentlock.com From Lock Body P4 to J4 06/30/09 Step #8 – Attach Connectors (Exterior PCB Assembly) Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 7A Harmony Series H2 8600 Exits Inside of Door (2) #8-32 x 5/8” Phillips Flat Head Under-cut Machine Screws Step #9 – Install Inside Escutcheon 1. Position inside gasket and escutcheon against door. Verify that no wires are being pinched. 2. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8" Phillips flat head undercut machine screws. Step #10 – Install Rail Assembly 1. Retrieve harness from end of rail. Harness has limited travel and can be damaged. Fig. 9A 2. Attach harness to female connector on chassis. 3. Install rail and screws per exit device instructions. Note: This view shows rim exit device version. 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 10A Step #11 - Concealed Door Position Switch Instructions (3287) Use SARGENT 3287 Concealed Door Position Switch with this Harmony H2 series product: Wiegand Access Control System (Others) 1. Install the 3287 Concealed Door Position Switch described in SARGENT document A7448B. 2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input. 3. Connect the common wire of the switch to the common input terminal of the EAC; and the normally open wire of the switch to the normally open input termnial of the EAC. 3287 Door Position Switch Lock is 12VDC. Optional 24VDC lock is available. McKinney QC12 Hinge Harmony Series H2 >> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. << 10 Fig. 11A A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8800 Exits Installation Instructions For Harmony Series H2 8800 Rim Exit Device Parts Breakdown Left Hand Reverse Door Shown Tools Required • Phillips screw driver (standard size) • Flat blade screw driver (standard) 6A 10 11 10 12 13 14 A8029A • 800-810-WIRE (9473) • www.sargentlock.com 11 06/30/09 15 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Harmony Series H2 8800 Exits Parts Breakdown For Harmony Series H2 8800 (Continued) Shipment Contents ITEM PART # Description 52-4038 Outside Harmony Escutcheon Assembly 52-0792 Outside Weather Gasket 52-0793 Inside Weather Gasket 52-5219 Harmony Inside Escutcheon Mounting Plate 52-5236 Screw Pack (Escutcheon) 68-1581 Inside Escutcheon Assembly 6A 52-4036 H2 Controller Assembly 68-3905 Screw Pack (Rail and Chassis Cover) 68-0406 Chassis Cover 68-3922 Screw Pack (Chassis) 10 13-0074 Cylinder Connecting Screws 11 68-7255 8800 Chassis Assembly (Standard) 68-7256 8800 Chassis Assembly (12-) 68-5836 8800 Chassis Assembly (GL) 68-5837 8800 Chassis Assembly (12-, GL) 12 13-0086 Cylinder back Plate Used with non-Sargent Cylinders) 13 52-0263 ET Trim Gasket *Harmony Trim is Ordered as "N1" 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 14 Req. N1-773-ET 12V Fail Safe Without Cylinder N1-773-ET 24V Fail Safe Without Cylinder N1-774-ET 12V Fail Secure Without Cylinder N1-774-ET 24V Fail Secure Without Cylinder N1-775-ET 12V Fail Safe Without Cylinder N1-775-ET 24V Fail Safe Without Cylinder N1-776-ET 12V Fail Secure Without Cylinder N1-776-ET 24V Fail Secure Without Cylinder 15 -- Reference Harmony Series Catalog for Available Cylinders 16 3287 DPS Door Position Switch (not shown) 17 A8029 Installation Instructions (not shown) 18 A7883 Field Template (not shown) 19 4615 Manufacturer Template (not shown) How to Specify ET Trim How to order without an exit device. Specify: 7 for 700 Series ET, Function, Suffix, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB). Note: Suffix requirements are based on type of device to be used: • -8 suffix is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44. • -6 suffix is required for all PP, PR, SP, LP, LR and LS devices. • -4 suffix is required for all 8400, WD, MD and AD 8600 devices. • No suffix is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices with these functions: 04, 10, 16, 40 and 44. 12 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8800 Exits Step #1 – Door Preparation Inside A. Verify Hand and Bevel of Door • Check hand of door. Exit Device may be handed. • Door should be fitted and hung. • Verify box label for size of exit device, function and hand. Left Hand Reverse LHR Right Hand Reverse RHR Outside Fig. 1A B. Door Preparation Prepare door according to appropriate template. If necessary, refer to website, www.intelligentopenings.com: Wood Door Shown • Field prep template: A7883 • Manufacturer template: 4615 • Reference exit device templates: 4415, and 4530 Fig. 1B Step #2 – Outside Trim (Exit Trim, ET) Installation 1. For exterior applications, use ET gasket (52-0263) to seal between ET escutcheon and outside door surface (Fig. 2B). ET Gasket 2. Route ET wire harness in cutout for wood doors and through access hole for metal doors (Fig. 2A). 3. Hold ET control onto door. Wire Harness Fig. 2B Detail ET Control Fig. 2A A8029A • 800-810-WIRE (9473) • www.sargentlock.com 13 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Note: Instruction examples show wood door installation. For metal doors, route cables inside door. Harmony Series H2 8800 Exits 8800 Installation Instructions (Continued) Step #3 – Mounting Chassis Inside of Door 1. Position chassis carefully, not to pinch wire harness. 2. ET spindle will engage the lower hub of chassis. 3. Cylinder tailpiece should engage upper hub of the chassis. 4. Though bolt chassis to ET with (2) 1/4 -20 x 2-3/8” flat head machine screws. 5. Using (4) #10 wood screws or #10-24 machine screws fasten chassis to door. #12 x 1” Phillips Flat Head Wood Screw Step #4 – Cylinder Installation 1. Position cylinder in ET control. 2. For non-Sargent cylinder ONLY: Secure cylinder with cylinder backplate using (2) #12-24 x 1-7/8” screws. Exit Chassis 3. Make sure ET harness is clear of cylinder and cylinder tailpiece. 1/4 -20 x 2-3/8” Flat Head Machine Screw Fig. 3A Cylinder 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. #12-24 X 1-7/8” Screws Inside of Door Inside of Door Fig. 4A Outside Gasket Step #5 – Outside Escutcheon and Inside Mounting Plate and Ground Wire Installation #8-32 x 2” Phillips Flat Head Screws 1. Connect pin 5 green/yellow ground wire ring terminal to top right screw (Fig. 5A and 5B). #8 x 1/2” SelfTaping Screws 1. Secure the mounting plate with (2) self-tapping screws (#8 x 1/2”). 2. Feed the reader cable connector located on the back of the outside escutcheon from the outside of door through door. 3. Securely tighten the outside escutcheon with (2) through-bolts (#8-32 x 2”) Phillips flat head screws through the mounting plate. Fig. 5B 14 Fig. 5A A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8800 Exits Step #6 – Install Gasket Add Gasket (if necessary): Gasket required for exterior door applications. Remember the inside gasket must be used when installing in an outdoor application. Remove backing and place gasket on door (Fig. 6A). Inside of Door Fig. 6A Step #7 – Connect ElectroLynx 1. Connect P5 (7 Pin Connector) from reader board to J5 on interior escutcheon PCB assembly (Fig. 7A). From Reader Board P5 to J5 2. Connect ElectroLynx harness (4 and 8-pin) from door harness to ElectroLynx harness on interior PCB assembly (Fig. 7A). J5 NOTES: J1 Neatly fold the wires onto themselves and into the remaining space to prevent pinching wires when mounting escutcheon. To ElectroLynx Harness Do not tuck extra mortise lock body wires back inside the lock body cylinder hole. J2 Connectors go on only one way. Fig. 7A Do not offset connector and be sure they are completely seated. PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex) 3 - Pink 1- Black 3-White 5-Orange 7-Brown (Solenoid, neg) NOT USED PWR NEG Wiegand DATA 1 RX (N/O) EGND 2-Gray, Lock DC Pos 4-Tan 2-Red 4-Green 6-Blue 8-Yellow (Solenoid, pos) NOT USED PWR POS Wiegand DATA 0 RX (COM) LED Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. J1 1-Violet Lock DC Neg Step #8 – Outside Escutcheon and Wire Positioning Outside of Door Please follow these steps prior to installing inside escutcheon assembly to prevent any damage caused by pinching wires: 1. Align the ElectroLynx® connectors (8 and 4-pin) to one side of the wire guide inside of the door prep. The reader connections and excess wire are arranged on the other. 2. Connect the ElectroLynx® connectors (8 and 4-pin) and establish their position inside of the door prep on the proper side of the wire guide (Fig. 8A). Rotate Clockwise 3. Neatly route the remaining wires onto themselves and into the remaining space to prevent pinching wires when mounting the escutcheon (Fig. 8B). Fig. 8A A8029A • 800-810-WIRE (9473) • www.sargentlock.com 15 Fig. 8B 06/30/09 J2 Harmony Series H2 8800 Exits Step #9 – Connector Attachment (Exterior PCB Assembly) 1. Connect P3 (2-pin connector) from lock body to J3 on module (Fig. 9A). 2. Connect P4 (6-pin connector) from lock body to J4 on module (Fig. 9A). From Lock Body P3 to J3 J3 J4 From Lock Body P4 to J4 Fig. 9A Step #10 – Installation of Inside Escutcheon 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 1. Position inside gasket and escutcheon against door. Verify that no wires are being pinched. 2. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8" Phillips flat head undercut machine screws. Inside of Door (2) #8-32 x 5/8” Phillips Flat Head Under-cut Machine Screws Fig. 10A 16 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Step #11 – Installation of Rail Assembly 1. Retrieve harness from end of rail. Harness has limited travel and can be damaged. 2. Attach harness to female connector on chassis. 3. Install rail and screws per exit device instructions. Note: This view shows rim exit device version Fig. 11A Wiegand Access Control System (Others) 1. Install the 3287 Concealed Door Position Switch described in SARGENT document A7448B. 2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input. 3. Connect the common wire of the switch to the common input terminal of the EAC; and the normally open wire of the switch to the normally open input termnial of the EAC. 3287 Door Position Switch Lock is 12VDC. Optional 24VDC lock is available. McKinney QC12 Hinge Harmony Series H2 Fig. 12A >> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. << A8029A • 800-810-WIRE (9473) • www.sargentlock.com 17 06/30/09 Use SARGENT 3287 Concealed Door Position Switch with this Harmony H2 series product: Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Step #12 - Concealed Door Position Switch (3287) Instructions Harmony Series H2 8900 Exits Installation Instructions For Harmony Series H2 8900 Mortise Exit Device Parts Breakdown Left Hand Reverse Door Shown Tools Required • Phillips screw driver (standard size) • Flat blade screw driver (standard) 6A 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 10 11 13 14 12 15 18 16 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8900 Exits Parts Breakdown For Harmony Series H2 8900 (Continued) Shipment Contents ITEM PART # Description 52-4038 Outside Harmony Escutcheon Assembly 52-0792 Outside Harmony Gasket 52-0793 Inside Harmony Gasket 52-5219 Harmony Inside Escutcheon Mounting Plate 52-5236 Screw Pack (Escutcheon) 68-1581 Inside Harmony Escutcheon Assembly 6A 52-4036 H2 Controller Assembly 68-3905 Screw Pack (Rail and Chassis Cover) 68-0407 Chassis Cover 68-3922 Screw Pack (Chassis) 10 68-7253 8900 Chassis Assembly LHRB 68-5754 8900 Chassis Assembly RHRB 52-0263 ET Trim Gasket 11 12 Req. *Harmony Trim is Ordered as "N1" N1-773-ET 12V Fail Safe Without Cylinder N1-773-ET 24V Fail Safe Without Cylinder N1-774-ET 12V Fail Secure Without Cylinder N1-774-ET 24V Fail Secure Without Cylinder N1-774-ET 12V Fail Secure With Cylinder N1-774-ET 24V Fail Secure With Cylinder 13 -- Reference Harmony Series Catalog for Available Cylinders 14 915 8900 Lock Body Assembly LHRB 915 8900 Lock Body Assembly RHRB 15 99-2628 Screw Pack (Mortise Lock) 16 99-0131TAB Strike Pack (Specify Bevel and Lip Length) 17 A8029 Instruction Sheet (not shown) 18 A7948 Field Prep Template (not shown) 19 4613 Manufacturer Template (not shown) How to Specify ET Trim How to order without an exit device. Specify: 7 for 700 Series ET, Function, Suffix, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB). Note: Suffix requirements are based on type of device to be used: • -8 suffix is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44. • -6 suffix is required for all PP, PR, SP, LP, LR and LS devices. • -4 suffix is required for all 8400, WD, MD and AD 8600 devices. • No suffix is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices with these functions: 04, 10, 16, 40 and 44. A8029A • 800-810-WIRE (9473) • www.sargentlock.com 19 06/30/09 N1-773-ET 24V Fail Safe With Cylinder Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. N1-773-ET 12V Fail Safe With Cylinder Harmony Series H2 8900 Exits Step #1 – Door Preparation Inside A. Verify Hand and Bevel of Door • Check hand of door. Exit Device may be handed. • Door should be fitted and hung. Left Hand Reverse LHR • Verify box label for size of exit device, function and hand. Right Hand Reverse RHR Outside Fig. 1A B. Door Preparation Wood Door Shown Prepare door according to appropriate template. If necessary, refer to website, www.intelligentopenings.com: • Field prep template: A7948 (ships with product) • Door manufacturer templates: 4613, 4290, and 4314. 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Note: Instruction examples show wood door installation. For metal doors, route cables inside door. Fig. 1B Step #2 – Mortise Lock and Outside Exit Trim (ET) Installation 1. Slide mortise lock into pocket and securely fasten with (2) flat head screws (Fig. 2A). 2. Route “ET” harness through wire cutout on inside of door. 3. For exterior applications, use gasket (52-0263) to seal between ET escutcheon and outside door surface (Fig. 2B Detail). 4. Place ET control on door with spindle engaging the mortise lock. Wire Mortise ET Gasket Fig. 2B Detail Fig. 2A ET (2) Flat Head Wood Screws 20 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8900 Exits 8900 Installation Instructions (Continued) Inside of Door Step #3 – Cylinder Installation For devices without cylinders, skip this section. 1. Back cylinder set screw out slightly (Fig. 3A). 2. Insert cylinder through “ET” control and thread into mortise lock until cylinder is flush with “ET”. Cylinder Set Screw Keyway must be vertical and SARGENT Cylinder Position Sargent Logo at top of cylinder (Fig. 3B). NT 3. Tighten cylinder set screw. RG SA SARGENT Correct Incorrect ET Control Fig. 3B Detail Fig. 3A Step #4 – Chassis to Door Installation 1. Route ET wire harness along track cutout for wood doors and access hole for metal doors (Fig. 4A). 2. Temporarily attach chassis to rail, then lock push rail down using hex or cylinder key or by holding push rail in the depressed position on 8900 exit device (Fig. 4B). ElectroLynx Connectors 3. Position chassis and rail on door so that lever arm is under rear section of mortise lock lever then lift up until latch bolt is completely retracted. With chassis in this position and rail horizontal, mark location of chassis mounting holes (Fig. 4C). Drill holes for screws. (2) 1/4-20 x 2-3/8” Flat Head Machine Screws (to secure ET) 4. Release push rail and disassemble chassis from rail. Mount chassis on door. Do not pinch harness wires. 5. Fasten exit chassis to door using (4) #10 wood screws or #10-24 x 3/4” machine screws. (4) #10 Wood Screws or #10-24 Machine Screws 6. Using (2) 1/4-20 x 2-3/8” flat head screws, attach “ET” to chassis. Chassis Exit Chassis Depress arm into rail opening and slide rail onto chassis. Chassis Latchbolt Push Rail Lever Lock Down Screw Rail Assembly Attach to chassis with (2) #8-32 x 3/8” Phillips Truss Head Machine Screws Fig. 4B Fig. 4C Lever Arm A8029A • 800-810-WIRE (9473) • www.sargentlock.com 21 06/30/09 Fig. 4A Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Wire Harness Harmony Series H2 8900 Exits Outside Gasket Step #5 – Outside Escutcheon and Inside Mounting Plate and Ground Wire Installation #8-32 x 2” Phillips Flat Head Screws 1. Connect pin 5 green/yellow ground wire ring terminal to top right screw (Fig. 5A and 5B). #8 x 1/2” SelfTaping Screws 1. Secure the mounting plate with (2) self-tapping screws (#8 x 1/2”). 2. Feed the reader cable connector located on the back of the outside escutcheon from the outside of door through door. 3. Securely tighten the outside escutcheon with (2) through-bolts (#8-32 x 2”) Phillips flat head screws through the mounting plate. Inside of Door Fig. 5A Fig. 5B Inside of Door Step #6 – Install Gasket Add Gasket (if necessary): Gasket required for exterior door applications. Remember the inside gasket must be used when installing in an outdoor application. 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Remove backing and place gasket on door (Fig. 6A). Step #7 – Connect ElectroLynx Fig. 6A 1. Connect P5 (7 Pin Connector) from reader board to J5 on interior escutcheon PCB assembly (Fig. 7A). 2. Connect ElectroLynx harness (4 and 8-pin) from door harness to ElectroLynx harness on interior PCB assembly (Fig. 7A). NOTES: From Reader Board P5 to J5 J5 J1 Neatly fold the wires onto themselves and into the remaining space to prevent pinching wires when mounting escutcheon. To ElectroLynx Harness Do not tuck extra mortise lock body wires back inside the lock body cylinder hole. J2 Connectors go on only one way. Do not offset connector and be sure they are completely seated. Fig. 7A PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex) J2 J1 1-Violet Lock DC Neg 3 - Pink 1- Black 3-White 5-Orange 7-Brown (Solenoid, neg) NOT USED PWR GND Wiegand DATA 1 RX (N/O) EGND 2-Gray, Lock DC Pos 4-Tan 2-Red 4-Green 6-Blue 8-Yellow (Solenoid, pos) NOT USED PWR POS Wiegand DATA 0 RX (COM) LED 22 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 8900 Exits Step #8 – Outside Escutcheon and Wire Positioning Outside of Door Please follow these steps prior to installing inside escutcheon assembly to prevent any damage caused by pinching wires: 1. Align the ElectroLynx® connectors (8 and 4-pin) to one side of the wire guide inside of the door prep. The reader connections and excess wire are arranged on the other. Rotate Clockwise 2. Connect the ElectroLynx® connectors (8 and 4-pin) and establish their position inside of the door prep on the proper side of the wire guide (Fig. 8A). 3. Neatly route the remaining wires onto themselves and into the remaining space to prevent pinching wires when mounting the escutcheon (Fig.8B). Fig. 8B Fig. 8A Step #9 – Connector Attachment (Exterior PCB Assembly) From Lock Body P3 to J3 J3 J4 Fig. 9A A8029A • 800-810-WIRE (9473) • www.sargentlock.com 23 From Lock Body P4 to J4 06/30/09 2. Connect P4 (6-pin connector) from lock body to J4 on module (Fig. 9A). Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 1. Connect P3 (2-pin connector) from lock body to J3 on module (Fig. 9A). Harmony Series H2 8900 Exits Step #10 – Installation of Inside Escutcheon Inside of Door 1. Position inside gasket and escutcheon against door. Verify that no wires are being pinched. (2) #8-32 x 5/8” Phillips Flat Head Under-cut Machine Screws 2. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8" Phillips flat head undercut machine screws. Step #11 – Installation of Rail Assembly 1. Retrieve harness from end of rail. Harness has limited travel and can be damaged. 2. Attach harness to female connector on chassis. 3. Install rail and screws per exit device instructions. 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Note: This view shows rim exit device version Fig. 10A Fig. 11A >> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. << Step #12 - Concealed Door Position Switch (3287) Instructions Use SARGENT 3287 Concealed Door Position Switch with this Harmony H2 series product: Wiegand Access Control System (Others) 1. Install the 3287 Concealed Door Position Switch described in SARGENT document A7448B. 2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input. 3. Connect the common wire of the switch to the common input terminal of the EAC; and the normally open wire of the switch to the normally open input termnial of the EAC. 3287 Door Position Switch Lock is 12VDC. Optional 24VDC lock is available. McKinney QC12 Hinge Harmony Series H2 Fig. 12A 24 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Exit Devices Wiring Diagrams Product 8 PIN CONNECTOR 1-Black 2-Red 3-White 4-Green 5-Orange 4 PIN CONNECTOR 6-Blue 7-Brown 8-Yellow 9-Violet 10-Gray 11-Pink 12-Tan DPS (NC) DPS (COM) N/A N/A ACCESS CONTROL DEVICES: Harmony H2 Exits, ElectroLynx wire Color / Function assignments 12/24VDC (Reader) SARGENT HARMONY SERIES, H2 Exits NEG POS WIEGAND WIEGAND RX RX EGND LED 12 OR 24 VDC (LOCK RELAY) DATA_1 DATA_0 NO COM EGND REF. *DIAGRAMS NEG POS *Diagrams on following pages Reader LED Configuration PIN 8 (Yellow – LED) The Harmony Series reader can be configured for (3) modes of LED operation. HID Programming cards are supported to configure the behavior for LED color activity. Call 1-800-WIRE for details. PIN 6 (Blue – RX COM) PIN 4 (Green – Data 0) PIN 2 (Red – Reader POS) Mode 1: • Red LED ‘ON’ when powered. PIN 1 (Black – Reader NEG) • Presenting a 13.56MHz credential causes LED to ‘FLICKER’ green and return to red state. PIN 3 (White – Data 1) PIN 5 (Orange – RX N/O) PIN 7 (Brown) • Reference *Diagram #1 as a function of power requirement (12VDC or 24VDC). Note: LED wire is unconnected. PIN 4 (Not Used) Mode 2: PIN 2 (Gray – Lock POS) • Green LED “ON” when powered. PIN 3 (Not Used) • Reference *Diagram #2 as a function of power requirement (12VDC or 24VDC). Note: LED wire must be connected to circuit GROUND of the system’s power supply. Mode 3: • EAC Panel controls LED operation. • Reference *Diagram #3 as a function of power requirement (12VDC or 24VDC). Note: Control of LED is a function of the EAC panel equipment (ie. relay) to toggle between green and red. Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader performance will be interfered (*Diagram #3). A8029A • 800-810-WIRE (9473) • www.sargentlock.com 25 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. PIN 1 (Violet – Lock NEG) 06/30/09 • No Flicker after presenting valid 13.56MHz credential. Harmony Series H2 Exit Devices Typical Harmony Exit Application Diagram (12/24VDC Lock) DIAGRAM #1 – MODE 1: RED LED ‘ON’ WHEN POWERED 12/24VDC SYSTEM • Reader Draw = 125mA • 12VDC Solenoid Draw = 500mA • 12VDC Total Current Draw = 625mA • 24VDC Solenoid Draw = 250mA • 24VDC Total Current Draw = 375mA ck Bla ite (C 3287 Door Position Switch Wh C) en (N Gre 120 VAC Input al) utr Ne e( it Wh d) Gn n( ee Gr Harmony Series H2 Requires 12 or 24 VDC 12/24VDC 12 Conductor ElectroLynx Harness From McKinney t) (Ho Power Supply (By Others) QC12 Electric Hinge From McKinney Electronic Access Control Panel (By Others) 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. READER NEG - Black, 1 READER POS - Red, 2 DATA 1 - White, 3 DATA 1 DATA 0 - Green, 4 DATA 0 RX (NO) - Orange, 5 RX (NO Option) RX (COM) - Blue, 6 RX (COM) *EGND - Brown, 7 LED - Yellow, 8 Use (NC) for Fail Safe Operation Not Used LOCK NEG - Violet, 9 LOCK POS - Gray, 10 H2 Harmony Exit Lock Relay DPS DPS (NO) Fail Secure Operation *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel. Failure to follow proper ESD safe grounding procedures could lead to equipment failure. 26 A8029A • 800-810-WIRE (9473) • www.sargentlock.com Harmony Series H2 Exit Devices Typical Harmony Exit Application Diagram (12/24VDC Lock) DIAGRAM #2 – MODE 2: GREEN LED ‘ON’ WHEN POWERED 12/24VDC SYSTEM • Reader Draw = 125mA • 12VDC Solenoid Draw = 500mA • 12VDC Total Current Draw = 625mA • 24VDC Solenoid Draw = 250mA • 24VDC Total Current Draw = 375mA ck Bla Harmony Series H2 Requires 12 or 24 VDC 12/24VDC 12 Conductor ElectroLynx Harness From McKinney d) Gn n( ee Gr Power Supply (By Others) QC12 Electric Hinge From McKinney Electronic Access Control Panel (By Others) READER NEG - Black, 1 READER POS - Red, 2 DATA 1 - White, 3 DATA 0 - Green, 4 RX (NO) - Orange, 5 RX (COM) - Blue, 6 DATA 1 DATA 0 RX (NO Option) RX (COM) Use (NC) for Fail Safe Operation *EGND - Brown, 7 LED - Yellow, 8 LOCK NEG - Violet, 9 LOCK POS - Gray, 10 H2 Harmony Exit DPS (NC) - Pink, 11 Lock Relay DPS DPS (COM) - Tan, 12 DPS (NO) Fail Secure Operation *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel. Failure to follow proper ESD safe grounding procedures could lead to equipment failure. A8029A • 800-810-WIRE (9473) • www.sargentlock.com 27 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 3287 Door Position Switch al) utr Ne e( it Wh 06/30/09 ite (C Wh C) en (N Gre 120 VAC Input t) (Ho Harmony Series H2 Exit Devices Typical Harmony Exit Application Diagram (12/24VDC Lock) DIAGRAM #3 – MODE 3: EAC PANEL CONFIGURABLE 12/24VDC SYSTEM • Reader Draw = 125mA • 12VDC Solenoid Draw = 500mA • 12VDC Total Current Draw = 625mA • 24VDC Solenoid Draw = 250mA • 24VDC Total Current Draw = 375mA ck Bla ite (C 12 Conductor ElectroLynx Harness From McKinney al) utr Ne e( it Wh d) Gn n( ee Gr Harmony Series H2 Requires 12 or 24 VDC 12/24DC 3287 Door Position Switch Wh C) en (N Gre 120 VAC Input t) (Ho Power Supply (By Others) 06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. QC12 Electric Hinge From McKinney Electronic Access Control Panel (By Others) READER NEG - Black, 1 READER POS - Red, 2 DATA 1 - White, 3 DATA 0 - Green, 4 RX (NO) - Orange, 5 RX (COM) - Blue, 6 DATA 1 DATA 0 RX (NO Option) RX (COM) *EGND - Brown, 7 LED - Yellow, 8 LED Use (NC) for Fail Safe Operation LOCK NEG - Violet, 9 LOCK POS - Gray, 10 H2 Harmony Exit Lock Relay DPS DPS (NO) Fail Secure Operation *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel. Failure to follow proper ESD safe grounding procedures could lead to equipment failure. 28 A8029A • 800-810-WIRE (9473) • www.sargentlock.com 10 Mechanical Operational Check For devices without cylinders, go to step 3. 1. For devices with cylinders, insert key into cylinder and rotate. 2. The key will retract the latch and rods, the key should rotate freely. 3. Depress inside rail to retract latch and rods. 11 Electrical Operational Check Note: Once electrical wiring has been successfully completed according to proper application, follow the following step: 1. Turn power ON. 2. Verify LED located on reader is ON - red or green, depending on reader configuration (see reader LED configuration). 3. Present credential and verify LED and sounder activity. 4. Verify valid card read at EAC Panel. 5. Verify system operation functions; i.e., when credential is presented to reader that the door unlocks. SARGENT 100 Sargent Drive New Haven, CT 06511 USA 800-481-8464 • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A8029A-06/30/09
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2009:07:16 10:21:03-04:00 Create Date : 2009:07:16 10:21:03-04:00 Metadata Date : 2009:07:16 10:21:03-04:00 Creator Tool : Adobe Acrobat 8.1 Combine Files Format : application/pdf Title : FCC Part 15 Creator : Brooke Copeland Document ID : uuid:533ea10e-48c1-4ae4-af5a-3f7e700ed756 Instance ID : uuid:fb5b67ea-b1bf-41ae-80d8-a1b44e6ad041 Producer : Adobe Acrobat 8.1 Page Count : 30 Author : Brooke CopelandEXIF Metadata provided by EXIF.tools