ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15

ASSA ABLOY Inc. Harmony H2 Series Lock FCC Part 15

Contents

Users Manual Bored and Exits

Download: ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15
Mirror Download [FCC.gov]ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15
Document ID1145728
Application IDmMaezOOAoaPpiAUL9lWZDQ==
Document DescriptionUsers Manual Bored and Exits
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize236.68kB (2958550 bits)
Date Submitted2009-07-28 00:00:00
Date Available2009-07-28 00:00:00
Creation Date2009-07-16 10:21:03
Producing SoftwareAdobe Acrobat 8.1
Document Lastmod2009-07-16 10:21:03
Document TitleFCC Part 15
Document CreatorAdobe Acrobat 8.1 Combine Files
Document Author: Brooke Copeland

Certification Exhibit
FCC ID: U4A-SCYPROX2
IC: 6982A-SCYPROX2
FCC Rule Part: 15.225
IC Radio Standards Specification: RSS-210
ACS Report Number: 09-0176 - 15C
Manufacturer: Assa Abloy, Inc.
Model: Bored/Exits, Mortise
Manual – Bored/Exits
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Installation Instructions
Harmony Series H2
8600, 8800, 8900 Exits
A8029A
06/09
Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Table of Contents
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Warning . ..................................................................................2
General Description..................................................................3
Hardware Specifications..........................................................3
Electronics Specifications........................................................3
H2 8600 Concealed Vertical Rod (CVR) Exit Device.................4
H2 8800 Rim Exit Device.........................................................11
H2 8900 Mortise Exit Device...................................................17
Wiring Diagrams.....................................................................24
Mechanical Operational Check..............................................28
10
Electrical Operational Check..................................................28
Warning
Warning: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced technician for help
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were
met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des
règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
Observe precautions for handling electrostatic sensitive devices.
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Exit Devices
General Description
The SARGENT Harmony H2 series exit devices (8600, 8800, 8900) are designed to interface with existing Wiegand
Electronic Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID
iCLASS® 13.56MHz technology. The Harmony series technology is backed by SARGENT Grade 1 mechanical hardware.
All exits include RX (request to exit) monitoring in the rail and an external Door Position Switch (DPS) for door position
monitoring. Harmony is available as 12VDC or 24VDC solenoid operated ET trim. Weatherseal gaskets are also included
for exterior door applications. The Harmony H2 iCLASS reader provides visual and audible indicators of lock state
(locked/unlocked).
Hardware Specifications
All Harmony Exit Devices
Harmony 8800 Series Rim
• Certified ANSI/BHMA A156.3 Grade 1
• Cylinder override available
• Push bar retracts latch from inside, allowing free egress
• Accepts all SARGENT rim cylinders (75/76 functions)
• Request-to-Exit (REX) Switch activated by pushing rail
• Key retracts latch (75/76 functions)
• Outside lever controlled by any 13.56MHz HID
iCLASS Wiegand credential
• Latch – 3/4” throw, stainless steel
• Fire rated devices available
Harmony 8900 Series
Mortise
• UL Listed
• Cylinder override available
• Exit devices furnished for 1-3/4” doors
• Accepts all
SARGENT mortise
cylinders (75/76 functions)
• Fail safe or fail secure available
• Door Position Switch (DPS, part #3287) supplied to
allow for monitoring
Weigand Access
Control System
• Key retracts latch
(75/76 functions)
• 12VDC/24VDC solenoid-operated ET trim
• Latch – 3/4” throw,
anti-friction, brass
• EAC Panel wiring to door must be shielded with a
drain. Drain terminated at EAC Panel controller
3287 Door
Position Switch
McKinney
Electronic
Transfer
Hinge
• The AFF is 41” for Standard Applications; when a 100
Series Auxiliary Control is used, 38” AFF is
recommended to meet local accessibility standards
Harmony Series H2
Electronics Specifications
12VDC System
24VDC System
• Reader Draw = 125mA
• Reader Draw = 125mA
• 12VDC Solenoid Draw = 500mA
• 24VDC Solenoid Draw = 250mA
• Total Current Draw = 625mA
• Total Current Draw = 375mA
Wire Gauge Charts
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 12VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 24VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
100
20
18
16
14
14
12
12
10
100
24
20
18
18
16
16
14
12
150
18
16
14
12
12
12
10
—
150
22
18
16
16
14
14
12
10
200
16
14
12
12
10
10
—
—
200
20
18
16
14
14
12
12
10
250
16
14
12
10
10
10
—
—
250
18
16
14
14
12
12
12
10
300
16
12
12
10
10
—
—
—
300
18
16
14
12
12
12
10
—
400
14
12
10
—
—
—
—
—
400
18
14
12
12
10
10
—
—
500
14
10
10
—
—
—
—
—
500
16
14
12
10
10
—
—
—
750
12
10
—
—
—
—
—
—
750
14
12
10
10
—
—
—
—
1,000
10
—
—
—
—
—
—
—
1,000
14
10
10
—
—
—
—
—
1,500
10
—
—
—
—
—
—
—
1,500
12
10
—
—
—
—
—
—
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
06/30/09
• Cylinder override available for 8600 CVR with 106
Series Auxiliary Control
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Harmony 8600 Series Concealed Vertical Rod (CVR)
Harmony Series H2 8600 Exits
Installation Instructions For Harmony Series H2 8600
Concealed Vertical Rod (CVR) Exit Device
Parts Breakdown
Tools Required
• Phillips screw driver (standard size)
• Flat blade screw driver (standard)
10
10A
10
16
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
15
11
14
13B
13A
12
17
17
18
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8600 Exits
Parts Breakdown For Harmony Series H2 8600 (Continued)
Shipment Contents
ITEM
PART #
Description
68-3577
Chassis Wood Door (WD) Screw Pack
68-3905
Chassis Metal Door (MD) Screw Pack (not shown)
68-7057
WD 8600 Top Assembly
68-7060
MD/AD 8600 Top Assembly (not shown)
94-0212
Aux Control Rod Adapter
52-4038
Outside Harmony Escutcheon Assembly
52-0792
Outside Harmony Gasket
52-0793
Inside Harmony Gasket
52-5219
Harmony Inside Escutcheon Mounting Plate
52-0801
Wire Guide
52-5236
Screw Pack (Escutcheon)
10
68-1581
Inside Harmony Escutcheon
10A
52-4036
H2 Controller Assembly
11
*Harmony Trim is Ordered as "N1"
Req.
N1-773-4 ETL12V Fail Safe
N1-773-4 ETL 24V Fail Safe
N1-774-4 ETL12V Fail Secure
ET Trim Gasket
13A
68-3859
WD Inner Case Assembly
13B
68-5067
MD/AD Inner Case Assembly
14
68-7241
8600 Chassis LHRB
68-7242
8600 Chassis RHRB (not shown)
15
68-0407
Chassis Cover
16
68-3905
Screw Pack (Rail and Chassis Cover)
17
68-0888
MD/WD Bottom Case Assembly
17
68-0037
AD Bottom Case Assembly
18
3287
DPS Door Position Switch (not shown)
19
A8029
Installation Instructions (not shown)
20
4621
MD/AD Door Manufacturer Template (not shown)
21
4622
Wood Door Manufacturer Template (not shown)
How to Specify ET Trim
How to order without an exit device.
Specify: 7 for 700 Series ET, Function, Suffix, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB).
Note: Suffix requirements are based on type of device to be used:
• -8 suffix is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44.
• -6 suffix is required for all PP, PR, SP, LP, LR and LS devices.
• -4 suffix is required for all 8400, WD, MD and AD 8600 devices.
• No suffix is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices
with these functions: 04, 10, 16, 40 and 44.
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
06/30/09
52-0263
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
N1-774-4 ETL 24V Fail Secure
12
Harmony Series H2 8600 Exits
Step #1 – Prepare Door
Inside
A. Verify Hand and Bevel of Door
• Check hand of door. Exit Device may be handed.
• Door should be fitted and hung.
• Verify box label for size of exit device, function and hand.
Left Hand
Reverse
LHR
Right Hand
Reverse
RHR
Outside
Fig. 1A
B. Door Preparation
Wood Door Shown
Prepare door according to appropriate template. If necessary,
refer to website, www.intelligentopenings.com:
• Metal door (MD/AD): A7002
- Templates: 4621 and 4445
• Wood door (WD): A3937
- Templates: 4622 and 4431
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Note: Instruction examples show wood door installation.
For metal/aluminum doors, route cables inside door.
Fig. 1B
Step #2 - Inner Case Assembly Installation
A. Wood Door (WD)
Install the inner case assembly with (2) #12 x 1” Phillips
flathead screw (Fig. 2A).
B. Metal Door (MD/AD)
1. Assemble rods to inner case.
2. Slide rod assembly into door and secure with #10-24 x 3/8”
screw for top inner case assembly and #10-24 x 1/2” screw
for bottom inner case assembly (Fig. 2B).
#10-24 x 3/8”
#10-24 x 1/2”
Fig. 2A
Fig. 2B
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8600 Exits
8600 Installation Instructions (Continued)
Step #3 – Install Outside Exit Trim (ET) and Chassis
A. Outside Trim
1. For exterior applications, use ET gasket (52-0263)
to seal ET escutcheon and outside door surface (Fig. 3A).
2. Route ET wire harness through inner chassis
assembly:
- For wood doors: Route wire harness in cutout.
- For metal doors: Route wire harness through
access hole.
Gasket
#10-24 x 3/8”
3. Mount ET trim to inner chassis assembly using
(2) # 1/2 -20 x 2-3/8” flat head machine screws.
ET spindle engages inside the inner chassis
assembly (Fig. 3B).
Fig. 3A
Fig. 3B
B. Chassis
1. Position chassis carefully onto the inner chassis assembly from the
inside of the door. Be careful not to pinch wire harness.
Step #4 – Attach Ground Wire and Install Outside
Escutcheon and Inside Mounting Plate
1. Connect pin 5 green/yellow ground wire ring terminal
to top right screw (Fig. 4A and 4B).
2. Secure the mounting plate with (2) #8 x 1/2”
self-tapping screws (Fig. 4A).
Fig. 3B
3. Feed the reader cable connector located
on the back of the outside escutcheon
from the outside of door through door.
#8-32 X 1/2”
4. Securely tighten the outside escutcheon with
through-bolts using (2) #8-32 x 2” Phillips flat
head screws through the mounting plate.
#8-32 X 2”
Fig. 4A
Inside of Door
Fig. 4B
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
06/30/09
Fig. 3C
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
(4) #12 x 1” Phillips
Flathead Screws
2. Fasten the chassis to door using (4) #12 x 1” Phillips
flathead screws (Fig. 3C).
Harmony Series H2 8600 Exits
Step #5 – Install Gasket
Add Gasket (if necessary):
Remember the inside gasket must be used
when installing in an outdoor application.
Inside of Door
Remove backing and place gasket
on door (Fig. 5A).
Gasket required
for exterior door
applications.
Fig. 5A
Step #6 – Connect ElectroLynx
1. Connect P5 (7 Pin Connector) from reader board
to J5 on interior escutcheon PCB assembly (Fig. 6A).
2. Connect ElectroLynx harness (4 and 8-pin) from door harness
to ElectroLynx harness on interior PCB assembly (Fig. 6A).
From Reader
Board P5 to J5
J5
NOTES:
J1
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Neatly fold the wires onto themselves and into the remaining
space to prevent pinching wires when mounting escutcheon.
To ElectroLynx
Harness
Do not tuck extra mortise lock body wires back inside the lock
body cylinder hole.
J2
Connectors go on only one way.
Fig. 6A
Do not offset connector and be sure they are completely seated.
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
J1
1-Violet Lock DC Neg
3 - Pink
1- Black
3-White
5-Orange
7-Brown
(Solenoid, neg)
NOT USED
PWR NEG
Wiegand DATA 1
RX (N/O)
EGND
2-Gray, Lock DC Pos
4-Tan
2-Red
4-Green
6-Blue
8-Yellow
(Solenoid, pos)
NOT USED
PWR POS
Wiegand DATA 0
RX (COM)
LED
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8600 Exits
Step #7 – Position Outside Wires
Inside of Door
Please follow these steps prior to installing
inside escutcheon to prevent any damage
caused by pinching wires:
1.
Once wires are arranged, position piece
at a rotated angle against the door, under
earth ground wire.
2.
Press piece against door unwhile turning
clockwise (Fig. 7A).
3.
Twist into place, perpendicular with door (Fig. 7B).
Rotate Clockwise
Fig. 7B
1. Connect P3 (2-pin connector) from lock body
to J3 on module (Fig. 8A).
2. Connect P4 (6-pin connector) from lock body
to J4 on module (Fig. 8A).
From Lock
Body P3 to J3
J3
J4
Fig. 8A
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
From Lock
Body P4 to J4
06/30/09
Step #8 – Attach Connectors (Exterior PCB Assembly)
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 7A
Harmony Series H2 8600 Exits
Inside of Door
(2) #8-32 x 5/8” Phillips
Flat Head Under-cut
Machine Screws
Step #9 – Install Inside Escutcheon
1. Position inside gasket and escutcheon against door.
Verify that no wires are being pinched.
2. Mount inside escutcheon assembly to plate using
(2) #8-32 x 5/8" Phillips flat head undercut
machine screws.
Step #10 – Install Rail Assembly
1. Retrieve harness from end of rail. Harness has limited travel
and can be damaged.
Fig. 9A
2. Attach harness to female connector on chassis.
3. Install rail and screws per exit device instructions.
Note: This view shows rim exit device version.
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 10A
Step #11 - Concealed Door Position Switch Instructions (3287)
Use SARGENT 3287 Concealed Door Position Switch with this
Harmony H2 series product:
Wiegand Access
Control System
(Others)
1. Install the 3287 Concealed Door Position Switch described in SARGENT
document A7448B.
2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input.
3. Connect the common wire of the switch to the common input terminal of the EAC;
and the normally open wire of the switch to the normally open input
termnial of the EAC.
3287 Door
Position Switch
Lock is 12VDC.
Optional 24VDC
lock is available.
McKinney
QC12 Hinge
Harmony Series H2
>> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. <<
10
Fig. 11A
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8800 Exits
Installation Instructions For Harmony Series H2 8800 Rim Exit Device
Parts Breakdown
Left Hand Reverse Door Shown
Tools Required
• Phillips screw driver (standard size)
• Flat blade screw driver (standard)
6A
10
11
10
12
13
14
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
11
06/30/09
15
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Harmony Series H2 8800 Exits
Parts Breakdown For Harmony Series H2 8800 (Continued)
Shipment Contents
ITEM
PART #
Description
52-4038
Outside Harmony Escutcheon Assembly
52-0792
Outside Weather Gasket
52-0793
Inside Weather Gasket
52-5219
Harmony Inside Escutcheon Mounting Plate
52-5236
Screw Pack (Escutcheon)
68-1581
Inside Escutcheon Assembly
6A
52-4036
H2 Controller Assembly
68-3905
Screw Pack (Rail and Chassis Cover)
68-0406
Chassis Cover
68-3922
Screw Pack (Chassis)
10
13-0074
Cylinder Connecting Screws
11
68-7255
8800 Chassis Assembly (Standard)
68-7256
8800 Chassis Assembly (12-)
68-5836
8800 Chassis Assembly (GL)
68-5837
8800 Chassis Assembly (12-, GL)
12
13-0086
Cylinder back Plate Used with non-Sargent Cylinders)
13
52-0263
ET Trim Gasket
*Harmony Trim is Ordered as "N1"
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
14
Req.
N1-773-ET 12V Fail Safe Without Cylinder
N1-773-ET 24V Fail Safe Without Cylinder
N1-774-ET 12V Fail Secure Without Cylinder
N1-774-ET 24V Fail Secure Without Cylinder
N1-775-ET 12V Fail Safe Without Cylinder
N1-775-ET 24V Fail Safe Without Cylinder
N1-776-ET 12V Fail Secure Without Cylinder
N1-776-ET 24V Fail Secure Without Cylinder
15
--
Reference Harmony Series Catalog for Available Cylinders
16
3287
DPS Door Position Switch (not shown)
17
A8029
Installation Instructions (not shown)
18
A7883
Field Template (not shown)
19
4615
Manufacturer Template (not shown)
How to Specify ET Trim
How to order without an exit device.
Specify: 7 for 700 Series ET, Function, Suffix, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB).
Note: Suffix requirements are based on type of device to be used:
• -8 suffix is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44.
• -6 suffix is required for all PP, PR, SP, LP, LR and LS devices.
• -4 suffix is required for all 8400, WD, MD and AD 8600 devices.
• No suffix is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices
with these functions: 04, 10, 16, 40 and 44.
12
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8800 Exits
Step #1 – Door Preparation
Inside
A. Verify Hand and Bevel of Door
• Check hand of door. Exit Device may be handed.
• Door should be fitted and hung.
• Verify box label for size of exit device, function and hand.
Left Hand
Reverse
LHR
Right Hand
Reverse
RHR
Outside
Fig. 1A
B. Door Preparation
Prepare door according to appropriate template. If necessary,
refer to website, www.intelligentopenings.com:
Wood Door Shown
• Field prep template: A7883
• Manufacturer template: 4615
• Reference exit device templates: 4415, and 4530
Fig. 1B
Step #2 – Outside Trim (Exit Trim, ET) Installation
1. For exterior applications, use ET gasket (52-0263) to seal between
ET escutcheon and outside door surface (Fig. 2B).
ET Gasket
2. Route ET wire harness in cutout for wood doors
and through access hole for metal doors (Fig. 2A).
3. Hold ET control onto door.
Wire Harness
Fig. 2B Detail
ET Control
Fig. 2A
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
13
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Note: Instruction examples show wood door
installation. For metal doors, route cables inside door.
Harmony Series H2 8800 Exits
8800 Installation Instructions (Continued)
Step #3 – Mounting Chassis
Inside of Door
1. Position chassis carefully, not to pinch wire harness.
2. ET spindle will engage the lower hub of chassis.
3. Cylinder tailpiece should engage upper hub of the chassis.
4. Though bolt chassis to ET with (2) 1/4 -20 x 2-3/8” flat head
machine screws.
5. Using (4) #10 wood screws or #10-24 machine screws fasten
chassis to door.
#12 x 1” Phillips Flat
Head Wood Screw
Step #4 – Cylinder Installation
1. Position cylinder in ET control.
2. For non-Sargent cylinder ONLY:
Secure cylinder with cylinder
backplate using
(2) #12-24 x 1-7/8” screws.
Exit Chassis
3. Make sure ET harness is clear of
cylinder and cylinder tailpiece.
1/4 -20 x 2-3/8” Flat
Head Machine Screw
Fig. 3A
Cylinder
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
#12-24 X 1-7/8” Screws
Inside of Door
Inside of Door
Fig. 4A
Outside Gasket
Step #5 – Outside Escutcheon and Inside
Mounting Plate and Ground Wire Installation
#8-32 x 2” Phillips
Flat Head Screws
1. Connect pin 5 green/yellow ground wire ring terminal to
top right screw (Fig. 5A and 5B).
#8 x 1/2” SelfTaping Screws
1. Secure the mounting plate with (2) self-tapping screws (#8 x 1/2”).
2. Feed the reader cable connector located on the back of the outside
escutcheon from the outside of door through door.
3. Securely tighten the outside escutcheon with (2) through-bolts
(#8-32 x 2”) Phillips flat head screws through the mounting plate.
Fig. 5B
14
Fig. 5A
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8800 Exits
Step #6 – Install Gasket
Add Gasket (if necessary):
Gasket required
for exterior door
applications.
Remember the inside gasket must be used
when installing in an outdoor application.
Remove backing and place gasket
on door (Fig. 6A).
Inside of Door
Fig. 6A
Step #7 – Connect ElectroLynx
1. Connect P5 (7 Pin Connector) from reader board
to J5 on interior escutcheon PCB assembly (Fig. 7A).
From Reader
Board P5 to J5
2. Connect ElectroLynx harness (4 and 8-pin) from door harness
to ElectroLynx harness on interior PCB assembly (Fig. 7A).
J5
NOTES:
J1
Neatly fold the wires onto themselves and into the remaining
space to prevent pinching wires when mounting escutcheon.
To ElectroLynx
Harness
Do not tuck extra mortise lock body wires back inside the lock
body cylinder hole.
J2
Connectors go on only one way.
Fig. 7A
Do not offset connector and be sure they are completely seated.
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
3 - Pink
1- Black
3-White
5-Orange
7-Brown
(Solenoid, neg)
NOT USED
PWR NEG
Wiegand DATA 1
RX (N/O)
EGND
2-Gray, Lock DC Pos
4-Tan
2-Red
4-Green
6-Blue
8-Yellow
(Solenoid, pos)
NOT USED
PWR POS
Wiegand DATA 0
RX (COM)
LED
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
J1
1-Violet Lock DC Neg
Step #8 – Outside Escutcheon and Wire Positioning
Outside of Door
Please follow these steps prior to installing inside escutcheon
assembly to prevent any damage caused by pinching wires:
1. Align the ElectroLynx® connectors (8 and 4-pin) to one side of
the wire guide inside of the door prep. The reader connections
and excess wire are arranged on the other.
2. Connect the ElectroLynx® connectors (8 and 4-pin) and
establish their position inside of the door prep on
the proper side of the wire guide (Fig. 8A).
Rotate Clockwise
3. Neatly route the remaining wires onto themselves and into
the remaining space to prevent pinching wires when
mounting the escutcheon (Fig. 8B).
Fig. 8A
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
15
Fig. 8B
06/30/09
J2
Harmony Series H2 8800 Exits
Step #9 – Connector Attachment
(Exterior PCB Assembly)
1. Connect P3 (2-pin connector) from lock body
to J3 on module (Fig. 9A).
2. Connect P4 (6-pin connector) from lock body
to J4 on module (Fig. 9A).
From Lock
Body P3 to J3
J3
J4
From Lock
Body P4 to J4
Fig. 9A
Step #10 – Installation of Inside Escutcheon
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1. Position inside gasket and escutcheon against door. Verify that no
wires are being pinched.
2. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8"
Phillips flat head undercut machine screws.
Inside of Door
(2) #8-32 x 5/8” Phillips
Flat Head Under-cut
Machine Screws
Fig. 10A
16
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Step #11 – Installation of Rail Assembly
1. Retrieve harness from end of rail. Harness has limited travel
and can be damaged.
2. Attach harness to female connector on chassis.
3. Install rail and screws per exit device instructions.
Note: This view shows rim exit device version
Fig. 11A
Wiegand Access
Control System
(Others)
1. Install the 3287 Concealed Door Position Switch described in SARGENT
document A7448B.
2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input.
3. Connect the common wire of the switch to the common input terminal of the EAC;
and the normally open wire of the switch to the normally open input
termnial of the EAC.
3287 Door
Position Switch
Lock is 12VDC.
Optional 24VDC
lock is available.
McKinney
QC12 Hinge
Harmony Series H2
Fig. 12A
>> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. <<
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
17
06/30/09
Use SARGENT 3287 Concealed Door Position Switch with this
Harmony H2 series product:
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Step #12 - Concealed Door Position Switch (3287) Instructions
Harmony Series H2 8900 Exits
Installation Instructions For Harmony Series H2 8900 Mortise Exit Device
Parts Breakdown
Left Hand Reverse Door Shown
Tools Required
• Phillips screw driver (standard size)
• Flat blade screw driver (standard)
6A
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10
11
13
14
12
15
18
16
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8900 Exits
Parts Breakdown For Harmony Series H2 8900 (Continued)
Shipment Contents
ITEM
PART #
Description
52-4038
Outside Harmony Escutcheon Assembly
52-0792
Outside Harmony Gasket
52-0793
Inside Harmony Gasket
52-5219
Harmony Inside Escutcheon Mounting Plate
52-5236
Screw Pack (Escutcheon)
68-1581
Inside Harmony Escutcheon Assembly
6A
52-4036
H2 Controller Assembly
68-3905
Screw Pack (Rail and Chassis Cover)
68-0407
Chassis Cover
68-3922
Screw Pack (Chassis)
10
68-7253
8900 Chassis Assembly LHRB
68-5754
8900 Chassis Assembly RHRB
52-0263
ET Trim Gasket
11
12
Req.
*Harmony Trim is Ordered as "N1"
N1-773-ET 12V Fail Safe Without Cylinder
N1-773-ET 24V Fail Safe Without Cylinder
N1-774-ET 12V Fail Secure Without Cylinder
N1-774-ET 24V Fail Secure Without Cylinder
N1-774-ET 12V Fail Secure With Cylinder
N1-774-ET 24V Fail Secure With Cylinder
13
--
Reference Harmony Series Catalog for Available Cylinders
14
915
8900 Lock Body Assembly LHRB
915
8900 Lock Body Assembly RHRB
15
99-2628
Screw Pack (Mortise Lock)
16
99-0131TAB
Strike Pack (Specify Bevel and Lip Length)
17
A8029
Instruction Sheet (not shown)
18
A7948
Field Prep Template (not shown)
19
4613
Manufacturer Template (not shown)
How to Specify ET Trim
How to order without an exit device.
Specify: 7 for 700 Series ET, Function, Suffix, Lever, Finish and handing (e.g., 775-8 ETL x 26D x RHRB).
Note: Suffix requirements are based on type of device to be used:
• -8 suffix is required for 8800, 8500, NB8700, PP, PR and SP8700 devices, except with these functions: 04, 10, 16, 40 and 44.
• -6 suffix is required for all PP, PR, SP, LP, LR and LS devices.
• -4 suffix is required for all 8400, WD, MD and AD 8600 devices.
• No suffix is necessary for all 8900, 8300, 8700 with bottom rod and 8800, 8500, NB8700, PP, PR & SP8700 devices
with these functions: 04, 10, 16, 40 and 44.
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
19
06/30/09
N1-773-ET 24V Fail Safe With Cylinder
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
N1-773-ET 12V Fail Safe With Cylinder
Harmony Series H2 8900 Exits
Step #1 – Door Preparation
Inside
A. Verify Hand and Bevel of Door
• Check hand of door. Exit Device may be handed.
• Door should be fitted and hung.
Left Hand
Reverse
LHR
• Verify box label for size of exit device, function and hand.
Right Hand
Reverse
RHR
Outside
Fig. 1A
B. Door Preparation
Wood Door Shown
Prepare door according to appropriate template. If necessary,
refer to website, www.intelligentopenings.com:
• Field prep template: A7948 (ships with product)
• Door manufacturer templates: 4613, 4290, and 4314.
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Note: Instruction examples show wood door installation.
For metal doors, route cables inside door.
Fig. 1B
Step #2 – Mortise Lock and Outside Exit Trim (ET) Installation
1. Slide mortise lock into pocket and securely fasten with (2) flat head screws (Fig. 2A).
2. Route “ET” harness through wire cutout on inside of door.
3. For exterior applications, use gasket (52-0263)
to seal between ET escutcheon and
outside door surface (Fig. 2B Detail).
4. Place ET control on door with spindle
engaging the mortise lock.
Wire
Mortise
ET
Gasket
Fig. 2B Detail
Fig. 2A
ET
(2) Flat Head Wood Screws
20
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8900 Exits
8900 Installation Instructions (Continued)
Inside of Door
Step #3 – Cylinder Installation
For devices without cylinders, skip this section.
1. Back cylinder set screw out slightly (Fig. 3A).
2. Insert cylinder through “ET” control and thread into
mortise lock until cylinder is flush with “ET”.
Cylinder Set Screw
Keyway must be vertical and SARGENT
Cylinder
Position Sargent Logo at top of cylinder (Fig. 3B).
NT
3. Tighten cylinder set screw.
RG
SA
SARGENT
Correct
Incorrect
ET Control
Fig. 3B Detail
Fig. 3A
Step #4 – Chassis to Door Installation
1. Route ET wire harness along track cutout for wood doors
and access hole for metal doors (Fig. 4A).
2. Temporarily attach chassis to rail, then lock push rail down
using hex or cylinder key or by holding push rail in the
depressed position on 8900 exit device (Fig. 4B).
ElectroLynx Connectors
3. Position chassis and rail on door so that lever
arm is under rear section of mortise lock lever
then lift up until latch bolt is completely
retracted. With chassis in this position and
rail horizontal, mark location of chassis
mounting holes (Fig. 4C). Drill holes for screws.
(2) 1/4-20 x 2-3/8” Flat
Head Machine Screws
(to secure ET)
4. Release push rail and disassemble chassis
from rail. Mount chassis on door.
Do not pinch harness wires.
5. Fasten exit chassis to door using
(4) #10 wood screws or #10-24 x 3/4”
machine screws.
(4) #10 Wood Screws
or #10-24 Machine Screws
6. Using (2) 1/4-20 x 2-3/8” flat head screws,
attach “ET” to chassis.
Chassis
Exit Chassis
Depress arm into rail opening
and slide rail onto chassis.
Chassis
Latchbolt
Push Rail
Lever
Lock Down Screw
Rail Assembly
Attach to chassis with (2) #8-32 x 3/8”
Phillips Truss Head Machine Screws
Fig. 4B
Fig. 4C
Lever Arm
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
21
06/30/09
Fig. 4A
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Wire Harness
Harmony Series H2 8900 Exits
Outside Gasket
Step #5 – Outside Escutcheon and Inside
Mounting Plate and Ground Wire Installation
#8-32 x 2” Phillips
Flat Head Screws
1. Connect pin 5 green/yellow ground wire ring terminal to
top right screw (Fig. 5A and 5B).
#8 x 1/2” SelfTaping Screws
1. Secure the mounting plate with (2) self-tapping screws (#8 x 1/2”).
2. Feed the reader cable connector located on the back of the outside
escutcheon from the outside of door through door.
3. Securely tighten the outside escutcheon with (2) through-bolts
(#8-32 x 2”) Phillips flat head screws through the mounting plate.
Inside of Door
Fig. 5A
Fig. 5B
Inside of Door
Step #6 – Install Gasket
Add Gasket (if necessary):
Gasket required
for exterior door
applications.
Remember the inside gasket must be used when installing in an
outdoor application.
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Remove backing and place gasket on door (Fig. 6A).
Step #7 – Connect ElectroLynx
Fig. 6A
1. Connect P5 (7 Pin Connector) from reader board
to J5 on interior escutcheon PCB assembly (Fig. 7A).
2. Connect ElectroLynx harness (4 and 8-pin) from door harness
to ElectroLynx harness on interior PCB assembly (Fig. 7A).
NOTES:
From Reader
Board P5 to J5
J5
J1
Neatly fold the wires onto themselves and into the remaining
space to prevent pinching wires when mounting escutcheon.
To ElectroLynx
Harness
Do not tuck extra mortise lock body wires back inside the lock
body cylinder hole.
J2
Connectors go on only one way.
Do not offset connector and be sure they are completely seated.
Fig. 7A
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
J1
1-Violet Lock DC Neg
3 - Pink
1- Black
3-White
5-Orange
7-Brown
(Solenoid, neg)
NOT USED
PWR GND
Wiegand DATA 1
RX (N/O)
EGND
2-Gray, Lock DC Pos
4-Tan
2-Red
4-Green
6-Blue
8-Yellow
(Solenoid, pos)
NOT USED
PWR POS
Wiegand DATA 0
RX (COM)
LED
22
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 8900 Exits
Step #8 – Outside Escutcheon and Wire Positioning
Outside of Door
Please follow these steps prior to installing inside escutcheon
assembly to prevent any damage caused by pinching wires:
1. Align the ElectroLynx® connectors (8 and 4-pin) to one side
of the wire guide inside of the door prep. The reader
connections and excess wire are arranged on the other.
Rotate Clockwise
2. Connect the ElectroLynx® connectors (8 and 4-pin) and
establish their position inside of the door prep on
the proper side of the wire guide (Fig. 8A).
3. Neatly route the remaining wires onto themselves and into
the remaining space to prevent pinching wires when
mounting the escutcheon (Fig.8B).
Fig. 8B
Fig. 8A
Step #9 – Connector Attachment
(Exterior PCB Assembly)
From Lock
Body P3 to J3
J3
J4
Fig. 9A
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
23
From Lock
Body P4 to J4
06/30/09
2. Connect P4 (6-pin connector) from lock body
to J4 on module (Fig. 9A).
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1. Connect P3 (2-pin connector) from lock body
to J3 on module (Fig. 9A).
Harmony Series H2 8900 Exits
Step #10 – Installation of Inside Escutcheon
Inside of Door
1. Position inside gasket and escutcheon against door. Verify that no
wires are being pinched.
(2) #8-32 x 5/8” Phillips
Flat Head Under-cut
Machine Screws
2. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8"
Phillips flat head undercut machine screws.
Step #11 – Installation of Rail Assembly
1. Retrieve harness from end of rail. Harness has limited travel
and can be damaged.
2. Attach harness to female connector on chassis.
3. Install rail and screws per exit device instructions.
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Note: This view shows rim exit device version
Fig. 10A
Fig. 11A
>> Continue to Section 9 for Wiring Diagrams to wire Device to EAC Panel. <<
Step #12 - Concealed Door Position Switch (3287) Instructions
Use SARGENT 3287 Concealed Door Position Switch with this
Harmony H2 series product:
Wiegand Access
Control System
(Others)
1. Install the 3287 Concealed Door Position Switch described in SARGENT
document A7448B.
2. Wire the 3287 Concealed Door Position Switch to the EAC door position Input.
3. Connect the common wire of the switch to the common input terminal of the EAC;
and the normally open wire of the switch to the normally open input
termnial of the EAC.
3287 Door
Position Switch
Lock is 12VDC.
Optional 24VDC
lock is available.
McKinney
QC12 Hinge
Harmony Series H2
Fig. 12A
24
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Exit Devices
Wiring Diagrams
Product
8 PIN CONNECTOR
1-Black
2-Red
3-White
4-Green
5-Orange
4 PIN CONNECTOR
6-Blue
7-Brown
8-Yellow
9-Violet
10-Gray
11-Pink
12-Tan
DPS
(NC)
DPS
(COM)
N/A
N/A
ACCESS CONTROL DEVICES: Harmony H2 Exits, ElectroLynx wire Color / Function assignments
12/24VDC
(Reader)
SARGENT HARMONY
SERIES,
H2 Exits
NEG
POS
WIEGAND
WIEGAND
RX
RX
EGND
LED
12 OR 24 VDC
(LOCK RELAY)
DATA_1
DATA_0
NO
COM
EGND
REF.
*DIAGRAMS
NEG
POS
*Diagrams on following pages
Reader LED Configuration
PIN 8 (Yellow – LED)
The Harmony Series reader can be configured for (3) modes of LED operation.
HID Programming cards are supported to configure the behavior for LED
color activity. Call 1-800-WIRE for details.
PIN 6 (Blue – RX COM)
PIN 4 (Green – Data 0)
PIN 2 (Red – Reader POS)
Mode 1:
• Red LED ‘ON’ when powered.
PIN 1 (Black – Reader NEG)
• Presenting a 13.56MHz credential causes LED to ‘FLICKER’
green and return to red state.
PIN 3 (White – Data 1)
PIN 5 (Orange – RX N/O)
PIN 7 (Brown)
• Reference *Diagram #1 as a function of power
requirement (12VDC or 24VDC).
Note: LED wire is unconnected.
PIN 4 (Not Used)
Mode 2:
PIN 2 (Gray – Lock POS)
• Green LED “ON” when powered.
PIN 3 (Not Used)
• Reference *Diagram #2 as a function of power
requirement (12VDC or 24VDC).
Note: LED wire must be connected to circuit GROUND of the
system’s power supply.
Mode 3:
• EAC Panel controls LED operation.
• Reference *Diagram #3 as a function of power requirement (12VDC or 24VDC).
Note: Control of LED is a function of the EAC panel equipment (ie. relay) to toggle between green and red.
Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader
performance will be interfered (*Diagram #3).
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
25
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
PIN 1 (Violet – Lock NEG)
06/30/09
• No Flicker after presenting valid 13.56MHz credential.
Harmony Series H2 Exit Devices
Typical Harmony Exit Application Diagram (12/24VDC Lock)
DIAGRAM #1 – MODE 1: RED LED ‘ON’ WHEN POWERED
12/24VDC SYSTEM
• Reader Draw = 125mA
• 12VDC Solenoid Draw = 500mA
• 12VDC Total Current Draw = 625mA
• 24VDC Solenoid Draw = 250mA
• 24VDC Total Current Draw = 375mA
ck
Bla
ite (C
3287 Door
Position Switch
Wh
C)
en (N
Gre
120 VAC
Input
al)
utr
Ne
e(
it
Wh
d)
Gn
n(
ee
Gr
Harmony Series H2
Requires 12 or 24 VDC
12/24VDC
12 Conductor
ElectroLynx Harness
From McKinney
t)
(Ho
Power Supply
(By Others)
QC12 Electric Hinge
From McKinney
Electronic Access
Control Panel
(By Others)
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 1
DATA 0 - Green, 4
DATA 0
RX (NO) - Orange, 5
RX (NO Option)
RX (COM) - Blue, 6
RX (COM)
*EGND - Brown, 7
LED - Yellow, 8
Use (NC) for Fail
Safe Operation
Not Used
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
H2 Harmony Exit
Lock Relay
DPS
DPS
(NO) Fail Secure
Operation
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
26
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Exit Devices
Typical Harmony Exit Application Diagram (12/24VDC Lock)
DIAGRAM #2 – MODE 2: GREEN LED ‘ON’ WHEN POWERED
12/24VDC SYSTEM
• Reader Draw = 125mA
• 12VDC Solenoid Draw = 500mA
• 12VDC Total Current Draw = 625mA
• 24VDC Solenoid Draw = 250mA
• 24VDC Total Current Draw = 375mA
ck
Bla
Harmony Series H2
Requires 12 or 24 VDC
12/24VDC
12 Conductor
ElectroLynx Harness
From McKinney
d)
Gn
n(
ee
Gr
Power Supply
(By Others)
QC12 Electric Hinge
From McKinney
Electronic Access
Control Panel
(By Others)
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
DATA 1
DATA 0
RX (NO Option)
RX (COM)
Use (NC) for Fail
Safe Operation
*EGND - Brown, 7
LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
H2 Harmony Exit
DPS (NC) - Pink, 11
Lock Relay
DPS
DPS (COM) - Tan, 12
DPS
(NO) Fail Secure
Operation
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
27
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
3287 Door
Position Switch
al)
utr
Ne
e(
it
Wh
06/30/09
ite (C
Wh
C)
en (N
Gre
120 VAC
Input
t)
(Ho
Harmony Series H2 Exit Devices
Typical Harmony Exit Application Diagram (12/24VDC Lock)
DIAGRAM #3 – MODE 3: EAC PANEL CONFIGURABLE
12/24VDC SYSTEM
• Reader Draw = 125mA
• 12VDC Solenoid Draw = 500mA
• 12VDC Total Current Draw = 625mA
• 24VDC Solenoid Draw = 250mA
• 24VDC Total Current Draw = 375mA
ck
Bla
ite (C
12 Conductor
ElectroLynx Harness
From McKinney
al)
utr
Ne
e(
it
Wh
d)
Gn
n(
ee
Gr
Harmony Series H2
Requires 12 or 24 VDC
12/24DC
3287 Door
Position Switch
Wh
C)
en (N
Gre
120 VAC
Input
t)
(Ho
Power Supply
(By Others)
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
QC12 Electric Hinge
From McKinney
Electronic Access
Control Panel
(By Others)
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
DATA 1
DATA 0
RX (NO Option)
RX (COM)
*EGND - Brown, 7
LED - Yellow, 8
LED
Use (NC) for Fail
Safe Operation
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
H2 Harmony Exit
Lock Relay
DPS
DPS
(NO) Fail Secure
Operation
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
28
A8029A • 800-810-WIRE (9473) • www.sargentlock.com
10 Mechanical Operational Check
For devices without cylinders, go to step 3.
1. For devices with cylinders, insert key into cylinder and rotate.
2. The key will retract the latch and rods, the key should rotate freely.
3. Depress inside rail to retract latch and rods.
11
Electrical Operational Check
Note: Once electrical wiring has been successfully
completed according to proper application, follow the
following step:
1. Turn power ON.
2. Verify LED located on reader is ON - red or green,
depending on reader configuration (see reader
LED configuration).
3. Present credential and verify LED and
sounder activity.
4. Verify valid card read at EAC Panel.
5. Verify system operation functions; i.e., when
credential is presented to reader that the
door unlocks.
SARGENT
100 Sargent Drive
New Haven, CT 06511 USA
800-481-8464 • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A8029A-06/30/09

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2009:07:16 10:21:03-04:00
Create Date                     : 2009:07:16 10:21:03-04:00
Metadata Date                   : 2009:07:16 10:21:03-04:00
Creator Tool                    : Adobe Acrobat 8.1 Combine Files
Format                          : application/pdf
Title                           : FCC Part 15
Creator                         : Brooke Copeland
Document ID                     : uuid:533ea10e-48c1-4ae4-af5a-3f7e700ed756
Instance ID                     : uuid:fb5b67ea-b1bf-41ae-80d8-a1b44e6ad041
Producer                        : Adobe Acrobat 8.1
Page Count                      : 30
Author                          : Brooke Copeland
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYPROX2

Navigation menu