ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15

ASSA ABLOY Inc. Harmony H2 Series Lock FCC Part 15

Contents

Users Manual Mortise

Download: ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15
Mirror Download [FCC.gov]ASSALOY SCYPROX2 Harmony H2 Series Lock User Manual FCC Part 15
Document ID1145729
Application IDmMaezOOAoaPpiAUL9lWZDQ==
Document DescriptionUsers Manual Mortise
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize131.15kB (1639375 bits)
Date Submitted2009-07-28 00:00:00
Date Available2009-07-28 00:00:00
Creation Date2009-07-16 10:19:13
Producing SoftwareAdobe Acrobat 8.1
Document Lastmod2009-07-16 10:19:13
Document TitleFCC Part 15
Document CreatorAdobe Acrobat 8.1 Combine Files
Document Author: Brooke Copeland

Certification Exhibit
FCC ID: U4A-SCYPROX2
IC: 6982A-SCYPROX2
FCC Rule Part: 15.225
IC Radio Standards Specification: RSS-210
ACS Report Number: 09-0176 - 15C
Manufacturer: Assa Abloy, Inc.
Model: Bored/Exits, Mortise
Manual – Mortise
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Installation Instructions
Harmony Series H2
Mortise Lock
A8027A
06/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Warning . ..................................................................................2
General Description..................................................................3
Hardware Specifications..........................................................3
Electronics Specifications........................................................3
Features....................................................................................3
Parts Breakdown......................................................................4
Installation Instructions...........................................................6
Wiring Diagrams.....................................................................14
Mechanical Operational Check..............................................18
10
Electrical Operational Check..................................................18
Warning
Warning: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced technician for help
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were
met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des
règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
06/30/09
Observe precautions for handling electrostatic sensitive devices.
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
General Description
The SARGENT Harmony series H2 mortise lock is designed to interface with existing Wiegand Electronic Access Control
(EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID iCLASS® 13.56MHz technology.
Harmony series technology is backed by SARGENT’s Grade 1 hardware. The mortise lock monitors Request to Exit and
door position monitoring all inside the lock body and is available in 12 or 24VDC. Weatherseal gaskets are also included
for exterior door applications. The Harmony H2 iCLASS reader provides visual (LED) and audible indicators of lock state
(locked/unlocked).
Hardware Specifications
• Inside lever provides RX signal and retracts latch
and deadbolt
• Latch: Stainless steel, 3⁄4” projection, one-piece
• Deadbolt: One-piece hardened stainless steel
• Door position switch within lock body
• Guardbolt: Stainless steel, non-handed
• Handed: Easily field reversible without opening case
• Locks furnished for 1-3/4” doors. Other door
thicknesses require confirmation with factory.
• Case: 12 gauge heavy duty wrought steel
• U.L. Listed (3 hr)
• Outside lever controlled by any 13.56MHz HID
iCLASS Wiegand credential
• Wire from EAC Panel to door must be shielded
with drain terminated at EAC Panel controller
Electronics Specifications
12VDC System
24VDC System
• Reader Draw = 125mA
• Reader Draw = 125mA
• 12VDC Solenoid Draw =500mA
• 24VDC Solenoid Draw = 250mA
• Total Current Draw = 625mA
• Total Current Draw = 375mA
Wire Gauge Charts
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 24VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
100
20
18
16
14
14
12
12
10
100
24
20
18
18
16
16
14
12
150
18
16
14
12
12
12
10
—
150
22
18
16
16
14
14
12
10
200
16
14
12
12
10
10
—
—
200
20
18
16
14
14
12
12
10
250
16
14
12
10
10
10
—
—
250
18
16
14
14
12
12
12
10
300
16
12
12
10
10
—
—
—
300
18
16
14
12
12
12
10
—
400
14
12
10
—
—
—
—
—
400
18
14
12
12
10
10
—
—
500
14
10
10
—
—
—
—
—
500
16
14
12
10
10
—
—
—
750
12
10
—
—
—
—
—
—
750
14
12
10
10
—
—
—
—
1,000
10
—
—
—
—
—
—
—
1,000
14
10
10
—
—
—
—
—
1,500
10
—
—
—
—
—
—
—
1,500
12
10
—
—
—
—
—
—
Features
Wiegand Access
Control System
• Complete monitoring of door via locks
• RX Setting (Dip-Switch Configurable for N/O, N/C and handing)
• Door Position (Integrated Secured/Unsecured)
• 24VDC System is available
• Fail Safe or Fail Secure solenoid version (must specify)
• Accepts all HID iCLASS 13.56MHz standard Wiegand bit formats
McKinney
Electronic
Transfer
Hinge
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony
Series H2
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Load Current @ 12VDC
06/30/09
Total
One-Way
Length of
Wire Run (ft)
Harmony Series H2 Mortise Lock
Parts Breakdown
Left Hand Reverse Door
6B
6A
2A
1A
1B
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
13
18
10
11
20
11A
12
14
Tools Required:
17
• Phillips Screw Driver (Standard size)
• Flat Blade Screw Driver (Standard size)
15A
• 1/8" Allen Wrench
15
19
16
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Parts Breakdown (Continued)
Left Hand Reverse Door
Description
52-4039
Outside Harmony Escutcheon With Cylinder Prep
Req.
1A
52-4040
Outside Harmony Escutcheon Without Cylinder Prep
1B
52-0732
Reader Gasket (Factory Installed)
52-0796
Outside Weather Gasket
52-0795
Inside Weather Gasket
52-5218
Mounting Plate
52-5236
Screw Pack (5A; 5B; 5C; 5D)
5A
77-1467
8 x 32 x 2" Phillips Head Flat Head Machine Screw
5B
01-9242
8 x 32 x 5/8" Phillips Head Flat Head Undercut Machine Screw
5C
01-1028
8 x 32 x 1/4"Phillips Head Flat Head Undercut Machine Screw
5D
01-1176
8 x 32 x 3/8" Phillips Head Flat Head Undercut Tapping Screw
52-5196
Inside Escutcheon W/ Turn Assembly
6A
82-0706
Inside Escutcheon W/O Turn Prep
6B
52-4036
H2 Controller Assembly
Reference Harmony Series Catalog For Available Lever Styles
Reference Harmony Series Catalog For Available Rose Styles
82-0368
Inside Spindle
10
01-1495
8-32 x 5/8" SCREWS
11
82-3088
Inside Adapter Plate And Bushing Assembly
11A
82-4577
Inside Adapter Plate And Bushing Assembly (Dl)
Reference Harmony Series Catalog For Available Lever Styles
Reference Harmony Series Catalog For Available Cylinders (Size 43)
"H2-82270-12/24 VDC x Finish"
W/O Deadbolt, Fail Safe
"H2-82271-12/24 VDC x Finish"
W/O Deadbolt, Fail Secure
"H2-82272-12/24 VDC x Finish"
W/O Deadbolt, Fail Safe, Both Levers Lock
"H2-82273-12/24 VDC x Finish"
W/O Deadbolt, Fail Secure, Both Levers Lock
"H2-82280-12/24 VDC x Finish"
W/ Deadbolt, Fail Safe
"H2-82281-12/24 VDC x Finish"
W/ Deadbolt, Fail Secure
"H2-82282-12/24 VDC x Finish"
W/ Deadbolt, Fail Safe, Both Levers Lock
"H2-82283-12/24 VDC x Finish"
W/ Deadbolt, Fail Secure, Both Levers Lock
12
13
14
Lock Body
15
82-0579
Electrical Outside Faceplate W/ Deadbolt
15A
82-0578
Electrical Outside Faceplate W/O Deadbolt
16
82-0110
Strike Plate
17
01-2299
#12 X 1 1/4" Phillips Flat Head Wood Screw
18
01-1019
12-24 X 1/2" Phillips Flat Head Undercut Machine Screw
19
01-1028
8-32 X 1/4" Phillips Flat Head Undercut Machine Screw
20
01-2298
#12 X 1" Phillips Flat Head Wood Screw
21
A7944
Field Prep Template
21B
4590
Door Manufacturer Template
22
A8027
Installation Instructions (Not Shown)
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Part #
06/30/09
Item
Harmony Series H2 Mortise Lock
Installation Instructions
Step #1 – Door Preparation
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
Left Hand
Hinges Left.
Open Inward.
“LH”
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
“LHRB”
Right Hand
Hinges Right.
Open Inward.
“RH”
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
“RHRB”
Fig. 1A
B. Door Preparation
Prepare door according to appropriate template. If necessary, refer to website, www.intelligentopenings.com:
• Prior to installation, make sure all holes are free of burrs, debris and sharp edges.
• If doors are not properly reinforced per ANSI115.2, commercially available reinforcements should be installed.
• Templates:
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
o Field prep: A7944 template ships with product.
o Manufacturer: 4590 wood and metal door template.
Outside of Door
Inside of Door
Raceway for 12 Conductor
Network/Power Cable
(ElectroLynx) from McKinney
Through-bolt Holes
(2 places)
Hole for Cable from
Reader to Controller Board
Pre-drilled and/or
Tapped Holes (2 places)
Outside Cylinder Hole
(70/71, 80/81
functions only)
Inside Cylinder Hole
Thumb Turn Hole
Lever Handle Hole
Lever Handle Hole
Mortise
Area
Pre-drilled and/or
Tapped Holes (2 Places)
Fig. 1B Wood Door
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Installation Instructions (Continued)
Step #2 – How to Reverse Lock Hand/Latch
A. Reverse Lock Hand
Right Hand
Lock Shown
Red surface of locking piece must face the outside/locked
side of door. To rotate locking piece (Fig. 2A1):
1. Position lock body with red surface of locking piece visible.
Locking Guide Slot:
Red color indicates
locked side.
2. Insert blade type screwdriver into locking piece slot
to rotate locking piece toward back of lock body.
3. Rotate the locking piece 180° until RED surface
is on opposite side.
Fig. 2A1
Push In
Note: Red indicates locked side (outside).
Wire harness MUST exit through non-cylinder side.
Make sure the plastic retaining ring is seated correctly (Fig. 2A2):
1. The wires and the plastic retaining ring must be
located on the non-cylinder side.
2. The orientation should place the word Bottom on
the opposite side from the wires.
3. Place the retaining ring under the wires with the
wires in the slot opposite the side marked Bottom.
4. The wires should be located in the slot on the
side - not through or under the retaining ring.
Plastic
Retaining
Ring
B. Reverse Latch Hand
Beveled surface of latch must face strike (Fig. 2B1).
The deadlatch is self adjusting.
Triangular Slot
To change hand of latchbolt:
1. Insert screwdriver blade into the spade shaped slot.
2. Rotate screwdriver 90º to push latch out until back
of latch clears lock front; then rotate latch 180º.
Latchbolt
Latch will then re-enter lock body.
Note: Latch cannot be unscrewed.
IMPORTANT: Must set the 4 position dip-switch RX
settings located on the rear of the mortise lock body
prior to lock installation (Step 3).
Fig. 2B1
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
06/30/09
Fig. 2A2
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Outside of Door
Harmony Series H2 Mortise Lock
Step #3 – Mortise Lock Body
RX Switch Settings
Four Position DIP Switch
Use four-position dip switch settings for appropriate
door application.
Be sure to follow the directions on the RX Dip Switch
sticker exactly.
Failure to follow sticker directions will cause inaccurate RX
activity to be reported to the access control panel.
Fig. 3A
RH and RH Reverse Door
LH and LH Reverse Door
ON
ON
Left Hand
Hinges Left.
Open Inward.
“LH”
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
“LHRB”
ON
Normally Open
Normally Open
Right Hand
Hinges Right.
Open Inward.
“RH”
Normally Closed
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
“RHRB”
ON
Normally Closed
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 3B Black circles indicate position of DIP switch
Step #4 – Lock body Installation
Wires and connectors go into the mortised area and out of the inside
cylinder hole.
Inside of Door
1. Insert mortise lock body into mortise door preparation.
2. Carefully feed wires from mortise lock through the non-cylinder side
hole of the door preparation.
3. Install appropriate hardware lock body screws.
Do not tighten at this time
Feed connectors
and wires through
non-cylinder side.
NOTE: Do not tighten screws completely.
Cylinder should be installed prior to tightening.
(2) #12-24 x 1/2” Long Flat
Head Screws (Metal Doors )
Fig. 4A
(2)#12 x 1-1/4” Long F!at Head
Wood Screws (Wood Doors)
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Step #5 – Outside Escutcheon and Inside Mounting Plate Installation
NOTE: Feed mortise connectors through the corresponding hole on the mounting plate.
1. Attach the mounting plate using (2) 8-32 x 3/8" Phillips flat head
undercut combo screws in the upper left and middle right
positions of the mounting plate and (2) 8-32 x 3/8" Phillips flat head
screws in the bottom positions (Fig 5A).
Inside of Door
2. Feed the reader cable located on the back of the outside escutcheon
through the door prep. Remember, the outside gasket must be used
when installing Harmony in an outdoor application (Fig 5B).
(2) 8-32 x 3/8” Phillips
Flat Head Undercut
Combo Screw
3. Secure the mounting plate to the outside escutcheon with
(2) #8-32 x 2”flat head machine screws (Fig 5C).
Outside of Door
(2) 8-32 x 3/8”
Phillips Flat
Head Screw
Gasket required
for exterior door
applications
Reader Cable
Fig. 5A
Step #6 – Install Gasket
Inside of Door
Add Gasket (if necessary):
Remember to place the inside gasket when
installing in an outdoor application.
Required for exterior
door applications.
Gasket fits snug around plate at top and sides,
leaving room for the hole at the bottom.
Remove backing and place gasket
on door (Fig. 6A).
Fig. 6A
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
06/30/09
Fig. 5B
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Inside of Door
Harmony Series H2 Mortise Lock
Step #7 – Connect Earth Ground
Connect pin-5 green/yellow ground wire ring terminal
to top right screw.
(2) #8-32 x 2”
Phillips Flat Head
Machine Screw
Fig. 7A2 Detail
Fig. 7A1
Step #8 – Outside Cylinder Installation
1. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 8A).
2. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig 8B).
06/30/09
Do not attempt to tighten all the way.
4. Tighten the cylinder clamp set screw to prevent unscrewing
of the cylinder (Fig 8C).
5. Test cylinder function:
Outside of Door
70/71 Function: Key retracts latch.
80/81 Function: Key retracts latch and
projects and retracts deadbolt.
Cylinder Set Screw
Ensure smooth operation of latchbolt
and deadbolt.
NOTE: Use lever handle holes to
manipulate mortise to ease thread
engagement of cylinder.
Phillips
Screwdriver
Fig. 8C
EN
RG
SARGENT
Position cylinder so that the
SARGENT logo is right-side up.
SA
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
3. Use the key to rotate the cylinder clockwise until it is flush at the bottom and the SARGENT logo is right-side up.
Correct
Incorrect
Fig. 8A
Fig. 8B
10
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Step #9 – Outside Lever and Inside Adapter Plate Assembly Installation
1. With outside lever horizontal, insert the mounting post through outside of door and lock body.
Make certain the lever spindle is properly engaged inside the lock body (Fig 9A).
Inside of Door
2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 9B).
3. Slide inside adapter and plate assembly over
spindle and loosely secure with (2) 8-32 X 5/8”
Phillips oval head and lock washer
machine screws.
Outside of Door
Be sure to rotate the set screw hole so
the hole (Studio Collection only) faces
the hinge side and seat the inside
spindle fully into the lock body.
4. Securely tighten the lock body screws.
8-32 X 5/8”
Phillips Oval
Head and
Lock Washer
Machine
Screw
Mortise
Lock body
Screw
Mortise
Lock body
Screw
Fig. 9B
From Reader
Board P5 to J5
1. Connect P5 (7 Pin Connector) from reader board
to J5 on interior escutcheon PCB assembly (Fig. 10A).
2. Connect ElectroLynx harness (4 and 8-pin) from door harness
to ElectroLynx harness on interior PCB assembly (Fig. 10A).
J5
J1
NOTES:
To ElectroLynx
Harness
Neatly fold the wires onto themselves and into the remaining
space to prevent pinching wires when mounting escutcheon.
J2
Do not tuck extra mortise lock body wires back inside the lock
body cylinder hole.
Fig. 10A
Connectors go on only one way.
Do not offset connector and be sure they are completely seated.
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
J1
1-Violet Lock Neg
3-Pink
1- Black
3-White
5-Orange
7-Brown
(Solenoid, neg)
DPS (NC)
PWR NEG
DATA 1
RX (NO/NC)
EGND
2-Gray Lock Pos
4-Tan
2-Red
4-Green
6-Blue
8-Yellow
(Solenoid, pos)
DPS (COM)
PWR POS
DATA 0
RX (COM)
LED
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
11
06/30/09
Step #10 – Connect ElectroLynx
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 9A
Harmony Series H2 Mortise Lock
Step #11 – Outside Wire Positioning
Inside of Door
Please follow these steps prior to installing
inside escutcheon to prevent any damage
caused by pinching wires:
Rotate Clockwise
1.
Once wires are arranged, position piece
at a rotated angle against the door, under
earth ground wire.
1.
Press piece against door while turning
clockwise (Fig. 11A).
2.
Twist into place, perpendicular with door (Fig. 11B).
Fig. 11A
Fig. 11B
Step #12 – Connector Attachment (Exterior PCB Assembly)
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1. Connect P3 (2-pin connector) from lock body
to J3 on module (Fig. 12A).
2. Connect P4 (6-pin connector) from lock body
to J4 on module (Fig. 12A).
From Lock
Body P3 to J3
J3
J4
From Lock
Body P4 to J4
Fig. 12A
12
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Step #13 – Inside Escutcheon Assembly Installation
Inside of Door
1. Tighten the inside escutcheon securely to the mounting
plate with the Phillips flat head machine screws provided.
Use the 8-32 x 5/8” for the top of the escutcheon
and the 8-32 x 1/4” screws for the bottom of the
escutcheon located under the turn lever.
Remember the inside gasket must be used
when installing Harmony in an outdoor application.
2. Be sure the turn assembly is functional
and the deadbolt functions properly.
8-32 X 5/8” Phillips
Flat Head Undercut
Machine Screw
8-32 X 1/4” Phillips
Flat Head Undercut
Machine Screw
Fig. 13A
2. Slide lever handle onto spindle until fully seated.
Be sure handle is horizontal and facing the hinge side
of the door.
Push lever onto spindle so minimum gap is visible.
3. Tighten the set screw securely with 1/8” hex wrench.
Inside of Door
Spindle
Rose
Set Screw
Fig. 14A
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
13
Inside Lever
Fig. 14B
06/30/09
1. Rotate the inside rose - first counter clockwise to
seat the threads and then, clockwise to securely tighten.
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Step #14 – Inside Rose and Inside Lever Assembly Instructions
Harmony Series H2 Mortise Lock
Outside of Door
Step #15 – Application of Front Plate
Attach front plate with (2) 8-32x1/4” flat head screws
and tighten securely.
Lock Body Screw
(2) 8-32x1/4”
Flat Head Screws
Fig. 135
Lock Body Screw
Wiring Diagrams
Product
8 PIN CONNECTOR
1-Black
2-Red
3-White
4-Green
5-Orange
4 PIN CONNECTOR
6-Blue
7-Brown
8-Yellow
9-Violet
10-Gray
11-Pink
12-Tan
DPS
(NC)
DPS
(COM)
DPS
DPS
ACCESS CONTROL DEVICES: Harmony H2 Mortise, ElectroLynx wire Color / Function assignments
12/24VDC
(Reader)
SARGENT HARMONY
SERIES,
H2 Mortise
NEG
POS
WIEGAND
WIEGAND
RX
RX
EGND
LED
12/24 VDC
(LOCK RELAY)
DATA_1
DATA_0
NO/NC
COM
REF.
*DIAGRAMS
REF.
*DIAGRAMS
NEG
POS
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
*Diagrams on following pages
Reader LED Configuration
The Harmony Series reader can be configured for (3) modes of LED operation.
HID Programming cards are also supported to configure the behavior for LED
color activity. Call 1-800-WIRE for details.
PIN8 (Yellow – LED)
PIN 6 (Blue – RX COM)
PIN 4 (Green – Data 0)
PIN 2 (Red – Reader POS)
Mode 1:
• Red LED ‘ON’ when powered.
• Presenting a 13.56MHz credential causes LED to ‘FLICKER’
green and return to red state.
PIN 1 (Black – Reader NEG)
PIN 3 (White – Data 1)
PIN 5 (Orange – RX NO/NC)
• Reference *Diagram #1 as a function of power
requirement (12VDC or 24VDC).
PIN 7 (Brown-EGND)
Note: LED wire is unconnected.
PIN 4 (Tan – DPS COM)
Mode 2:
PIN 2 (Gray – Lock POS)
• Green LED “ON” when powered.
• No Flicker after presenting valid 13.56MHz credential.
PIN 1 (Violet – Lock NEG)
PIN 3 (Pink – DPS NC)
• Reference *Diagram #2 as a function of power
requirement (12VDC or 24VDC).
Note: LED wire must be connected to circuit GROUND of the system’s power supply.
Mode 3:
• EAC Panel controls LED operation.
• Reference *Diagram #3 as a function of power requirement (12VDC or 24VDC).
Note: Control of LED is a function of the EAC panel equipment (ie. relay) to toggle between green and red.
Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader
performance will be interfered (*Diagram #3).
14
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Typical Harmony Mortise Lock Application Diagram (12/24VDC Lock)
DIAGRAM #1 – MODE 1: RED LED ‘ON’ WHEN POWERED
12/24VDC SYSTEM
• Reader Draw = 125mA
• 12VDC Solenoid Draw = 500mA
• 12VDC Total Current Draw = 625mA
• 24VDC Solenoid Draw = 250mA
• 24VDC Total Current Draw = 375mA
ck
Bla
12 Conductor
ElectroLynx Harness
From McKinney
120 VAC
Input
t)
(Ho
al)
utr
Ne
e(
it
Wh
d)
Gn
n(
ee
Gr
Harmony Series H2
Requires 12 or 24VDC
12/24VDC
Power Supply
(By Others)
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 1
DATA 0 - Green, 4
Electronic Access
Control Panel
(By Others)
DATA 0
RX (NO/NC) - Orange, 5
RX
*EGND - Brown, 7
LED - Yellow, 8
Not Used
Use (NC) for Fail
Safe Operation
LOCK NEG - Violet, 9
H2 Harmony
Mortise Lock
Lock Relay
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS
DPS (COM) - Tan, 12
DPS
(NO) Fail
Secure Operation
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
15
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
RX
RX (COM) - Blue, 6
06/30/09
QC12 Electric Hinge
From McKinney
Harmony Series H2 Mortise Lock
Typical Harmony Mortise Lock Application Diagram (12/24VDC Lock)
DIAGRAM #2 – MODE 2: GREEN LED ‘ON’ WHEN POWERED
12/24VDC SYSTEM
• Reader Draw = 125mA
• 12VDC Solenoid Draw = 500mA
• 12VDC Total Current Draw = 625mA
• 24VDC Solenoid Draw = 250mA
• 24VDC Total Current Draw = 375mA
ck
Bla
t)
(Ho
hit
al)
utr
(Ne
Gr
d)
Gn
en
Harmony Series H2
Requires 12 or 24VDC
H N G
120 VAC 12/24VDC
Input
- +
12 Conductor
ElectroLynx Harness
From McKinney
Power Supply
(By Others)
QC12 Electric Hinge
From McKinney
READER NEG - Black, 1
READER POS - Red, 2
06/30/09
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
DATA 1 - White, 3
DATA 1
DATA 0 - Green, 4
Electronic Access
Control Panel
(By Others)
DATA 0
RX (NO/NC) - Orange, 5
RX (COM) - Blue, 6
RX
RX
*EGND - Brown, 7
LED - Yellow, 8
Use (NC) for Fail
Safe Operation
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
H2 Harmony
Mortise Lock
DPS (NC) - Pink, 11
Lock Relay
DPS
DPS (COM) - Tan, 12
DPS
(NO) Fail
Secure Operation
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
16
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
Harmony Series H2 Mortise Lock
Typical Harmony Mortise Lock Application Diagram (12/24VDC Lock)
DIAGRAM #3 – MODE 3: EAC PANEL CONFIGURABLE
12/24VDC SYSTEM
• Reader Draw = 125mA
• 12VDC Solenoid Draw = 500mA
• 12VDC Total Current Draw = 625mA
• 24VDC Solenoid Draw = 250mA
• 24VDC Total Current Draw = 375mA
ck
Bla
t)
(Ho
al)
utr
Ne
e(
it
Wh
d)
Gn
n(
ee
Gr
H N G
120 VAC 12/24VDC
Input
- +
12 Conductor
ElectroLynx Harness
From McKinney
Harmony Series H2
Requires 12 or 24VDC
Power Supply
(By Others)
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 1
DATA 0 - Green, 4
Electronic Access
Control Panel
(By Others)
RX (COM) - Blue, 6
RX
RX
*EGND - Brown, 7
LED - Yellow, 8
Use (NC) for Fail
Safe Operation
LED
LOCK NEG - Violet, 9
Lock Relay
LOCK POS - Gray, 10
H2 Harmony
Mortise Lock
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
DPS
DPS
(NO) Fail
Secure Operation
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
A8027A • 800-810-WIRE (9473) • www.sargentlock.com
17
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
DATA 0
RX (NO/NC) - Orange, 5
06/30/09
QC12 Electric Hinge
From McKinney
9
Mechanical Operational Check
For 82280-82283 & 82270-82273 Function mortise locks with cylinders:
1. Insert key into cylinder and rotate: There should be no friction against
lock case, wire harness or any other obstructions.
2. The key will retract the latch: Key should rotate freely.
3. When the deadbolt is thrown: Ensure that the key retracts both the
deadbolt and the latch.
4. Inside lever: When used, ensure it retracts both the latch
and deadbolt (if provided).
5. Close door: Ensure latch and deadbolt fully extend
and do not bind.
10 Electrical Operational Check
Note: Once electrical wiring has been successfully
completed according to proper application, follow
the following step:
1. Turn power ON.
2. Verify LED located on reader is ON - red or green,
depending on reader configuration (see reader LED
configuration).
3. Present credential and verify LED and sounder activity.
4. Verify valid card read at EAC Panel.
5. Verify system operation functions; i.e., when credential
is presented to reader that the door unlocks.
SARGENT
100 Sargent Drive
New Haven, CT 06511 USA
800-481-8464 • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A8027A-06/30/09

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2009:07:16 10:19:13-04:00
Create Date                     : 2009:07:16 10:19:13-04:00
Metadata Date                   : 2009:07:16 10:19:13-04:00
Creator Tool                    : Adobe Acrobat 8.1 Combine Files
Format                          : application/pdf
Title                           : FCC Part 15
Creator                         : Brooke Copeland
Document ID                     : uuid:32aec6f9-4f0e-4488-b0bf-6d4a44ed9642
Instance ID                     : uuid:0d12304c-86c6-4253-86e3-da7a4a7da5d6
Producer                        : Adobe Acrobat 8.1
Page Count                      : 19
Author                          : Brooke Copeland
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYPROX2

Navigation menu