    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-SCYPROX2 IC: 6982A-SCYPROX2  FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210  ACS Report Number:  09-0176 - 15C   Manufacturer: Assa Abloy, Inc. Model: Bored/Exits, Mortise     Manual – Mortise
A8027A06/09Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written  permission of Sargent Manufacturing Company is prohibited. Installation InstructionsHarmony Series H2Mortise Lock
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/091234567Table of ContentsWarning  ...................................................................................2General Description .................................................................3Hardware Specifications .........................................................3Electronics Specifications .......................................................3Features ...................................................................................3Parts Breakdown .....................................................................4Installation Instructions ..........................................................6Wiring Diagrams ....................................................................14Mechanical Operational Check .............................................18Electrical Operational Check .................................................188910This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi-dential installation.This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the inter-ference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna• Increase the separation between the equipment and receiver• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected• Consult the dealer or an experienced technician for helpThe term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)  this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.Warning: Changes or modications to this unit not expressly approved by the party  responsible for compliance could void the user’s authority to operate the equipment.Warning 1Observe precautions for handling electrostatic sensitive devices.!A8027A • 800-810-WIRE (9473) • www.sargentlock.com 2
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 3Electronics SpecificationsGeneral DescriptionThe SARGENT Harmony series H2 mortise lock is designed to interface with existing Wiegand Electronic Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID iCLASS® 13.56MHz technology. Harmony series technology is backed by SARGENT’s Grade 1 hardware. The mortise lock monitors Request to Exit and door position monitoring all inside the lock body and is available in 12 or 24VDC. Weatherseal gaskets are also included for exterior door applications. The Harmony H2 iCLASS reader provides visual (LED) and audible indicators of lock state (locked/unlocked).3425Features• Complete monitoring of door via locks• RX Setting (Dip-Switch Congurable for N/O, N/C and handing)• Door Position (Integrated Secured/Unsecured)• 24VDC System is available• Fail Safe or Fail Secure solenoid version (must specify)• Accepts all HID iCLASS 13.56MHz standard Wiegand bit formatsTotal One-Way  Length of  Wire Run (ft)Load Current @ 12VDC1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A100 20 18 16 14 14 12 12 10150 18 16 14 12 12 12 10 —200 16 14 12 12 10 10 — —250 16 14 12 10 10 10 — —300 16 12 12 10 10 — — —400 14 12 10 — — — — —500 14 10 10 — — — — —7501210——————1,000 10 — — — — — — —1,500 10 — — — — — — —Total One-Way  Length of  Wire Run (ft)Load Current @ 24VDC1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A100 24 20 18 18 16 16 14 12150 22 18 16 16 14 14 12 10200 20 18 16 14 14 12 12 10250 18 16 14 14 12 12 12 10300 18 16 14 12 12 12 10 —400 18 14 12 12 10 10 — —500 16 14 12 10 10 — — —750 14 12 10 10 — — — —1,000 14 10 10 — — — — —1,500 12 10 — — — — — —Hardware Specifications• Latch: Stainless steel, 3⁄4” projection, one-piece• Deadbolt: One-piece hardened stainless steel• Guardbolt: Stainless steel, non-handed• Handed: Easily eld reversible without opening case• Case: 12 gauge heavy duty wrought steel• Outside lever controlled by any 13.56MHz HID     iCLASS Wiegand credential• Inside lever provides RX signal and retracts latch       and deadbolt• Door position switch within lock body• Locks furnished for 1-3/4” doors. Other door     thicknesses require conrmation with factory.• U.L. Listed (3 hr)• Wire from EAC Panel to door must be shielded     with drain terminated at EAC Panel controller12VDC System• Reader Draw = 125mA• 12VDC Solenoid Draw =500mA• Total Current Draw = 625mAWire Gauge Charts24VDC System• Reader Draw = 125mA • 24VDC Solenoid Draw = 250mA• Total Current Draw = 375mAHarmony Series H2McKinneyElectronic TransferHingeWiegand Access Control System
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com4Parts Breakdown5Left Hand Reverse DoorTools Required:• Phillips Screw Driver (Standard size)• Flat Blade Screw Driver (Standard size)• 1/8" Allen Wrench1311A22A345566A72018816191515A17141211A111096B1B
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 5Item Part #  Description Req.1 52-4039 Outside Harmony Escutcheon With Cylinder Prep  11A 52-4040 Outside Harmony Escutcheon Without Cylinder Prep 11B 52-0732 Reader Gasket (Factory Installed) 12 52-0796 Outside Weather Gasket 13 52-0795 Inside Weather Gasket 14 52-5218 Mounting Plate 15 52-5236 Screw Pack  (5A; 5B; 5C; 5D) 15A 77-1467 8 x 32 x 2"  Phillips Head Flat Head Machine Screw 25B 01-9242 8 x 32 x 5/8" Phillips Head Flat Head Undercut Machine Screw 25C 01-1028 8 x 32 x 1/4"Phillips Head Flat Head Undercut Machine Screw 15D 01-1176 8 x 32 x 3/8" Phillips Head Flat Head Undercut Tapping Screw 46 52-5196 Inside Escutcheon W/ Turn Assembly 16A 82-0706 Inside Escutcheon W/O Turn Prep 16B 52-4036 H2 Controller Assembly 17 Reference Harmony Series Catalog For Available Lever Styles 18 Reference Harmony Series Catalog For Available Rose Styles 19 82-0368 Inside Spindle 110 01-1495 8-32 x 5/8" SCREWS 211 82-3088 Inside Adapter Plate And Bushing Assembly 111A 82-4577 Inside Adapter Plate And Bushing Assembly (Dl) 112 Reference Harmony Series Catalog For Available Lever Styles 113 Reference Harmony Series Catalog For Available Cylinders (Size 43) 114 Lock Body "H2-82270-12/24 VDC x Finish"  W/O Deadbolt, Fail Safe 1"H2-82271-12/24 VDC x Finish"  W/O Deadbolt, Fail Secure 1"H2-82272-12/24 VDC x Finish"  W/O Deadbolt, Fail Safe, Both Levers Lock 1"H2-82273-12/24 VDC x Finish"  W/O Deadbolt, Fail Secure, Both Levers Lock 1"H2-82280-12/24 VDC x Finish"  W/ Deadbolt, Fail Safe 1"H2-82281-12/24 VDC x Finish"  W/ Deadbolt, Fail Secure 1"H2-82282-12/24 VDC x Finish"  W/ Deadbolt, Fail Safe, Both Levers Lock 1"H2-82283-12/24 VDC x Finish"  W/ Deadbolt, Fail Secure, Both Levers Lock 115 82-0579 Electrical Outside Faceplate W/ Deadbolt 115A 82-0578 Electrical Outside Faceplate W/O Deadbolt 116 82-0110 Strike Plate 117 01-2299 #12 X 1 1/4" Phillips Flat Head Wood Screw 218 01-1019 12-24 X 1/2" Phillips Flat Head Undercut Machine Screw 419 01-1028 8-32 X 1/4" Phillips Flat Head Undercut Machine Screw 220 01-2298 #12 X 1" Phillips Flat Head Wood Screw 221 A7944 Field Prep Template21B 4590 Door  Manufacturer Template 22 A8027 Installation Instructions (Not Shown)Parts Breakdown (Continued)Left Hand Reverse Door
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com6Installation Instructions6Step #1 – Door PreparationLeft HandHinges Left.Open Inward.“LH”Left HandReverse BevelHinges Left.Open Outward“LHRB”Right HandHinges Right.Open Inward.“RH”Right HandReverse BevelHinges Right.Open Outward“RHRB”A. Verify Hand and Bevel of DoorStand on outside of locked door when determining door hand.B. Door PreparationPrepare door according to appropriate template. If necessary, refer to website, www.intelligentopenings.com:• Prior to installation, make sure all holes are free of burrs, debris and sharp edges.• If doors are not properly reinforced per ANSI115.2, commercially available reinforcements should be installed.• Templates: o Field prep: A7944 template ships with product. o Manufacturer: 4590 wood and metal door template. Outside of Door Inside of DoorRaceway for 12 ConductorNetwork/Power Cable(ElectroLynx) from McKinneyHole for Cable fromReader to Controller BoardPre-drilled and/orTapped Holes (2 places)Inside Cylinder HoleThrough-bolt Holes(2 places)Outside Cylinder Hole(70/71, 80/81 functions only)Lever  Handle HoleThumb Turn Hole Lever Handle HoleMortise AreaPre-drilled and/orTapped Holes (2 Places)Fig. 1AFig. 1B Wood Door
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 7Triangular SlotLatchboltInstallation Instructions (Continued)Step #2 – How to Reverse Lock Hand/LatchRed surface of locking piece must face the outside/locked  side of door. To rotate locking piece (Fig. 2A1):1. Position lock body with red surface of locking piece visible.2. Insert blade type screwdriver into locking piece slot      to rotate locking piece toward back of lock body.3. Rotate the locking piece 180° until RED surface      is on opposite side.    Note: Red indicates locked side (outside).      Wire harness MUST exit through non-cylinder side. Make sure the plastic retaining ring is seated correctly (Fig. 2A2):1. The wires and the plastic retaining ring must be       located on the non-cylinder side. 2. The orientation should place the word Bottom on     the opposite side from the wires.3. Place the retaining ring under the wires with the      wires in the slot opposite the side marked Bottom.  4. The wires should be located in the slot on the       side - not through or under the retaining ring.A. Reverse Lock HandB. Reverse Latch HandBeveled surface of latch must face strike (Fig. 2B1). The deadlatch is self adjusting. To change hand of latchbolt:1. Insert screwdriver blade into the spade shaped slot.2. Rotate screwdriver 90º to push latch out until back      of latch clears lock front; then rotate latch 180º. Latch will then re-enter lock body.Note: Latch cannot be unscrewed.IMPORTANT: Must set the 4 position dip-switch RX      settings located on the rear of the mortise lock body      prior to lock installation (Step 3).Fig.  2B1Fig.  2A1Plastic Retaining RingOutside of DoorFig.  2A2Locking Guide Slot:Red color indicateslocked side. Push InRight  HandLock Shown
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com8(2)#12  x  1-1/4”  Long  F!at  Head Wood Screws (Wood Doors)Fig. 4AStep #3 – Mortise Lock Body  RX Switch Settings Four Position DIP SwitchUse four-position dip switch settings for appropriate  door application.Be sure to follow the directions on the RX Dip Switch  sticker exactly.Failure to follow sticker directions will cause inaccurate RX activity to be reported to the access control panel. Fig. 3AStep #4 – Lock body InstallationWires and connectors go into the mortised area and out of the inside cylinder hole.1. Insert mortise lock body into mortise door preparation.2. Carefully feed wires from mortise lock through the non-cylinder side      hole of the door preparation. 3. Install appropriate hardware lock body screws.    Do not tighten at this time    NOTE: Do not tighten screws completely.    Cylinder should be installed prior to tightening.Inside of Door(2) #12-24 x 1/2” Long  FlatHead Screws (Metal Doors )Feed connectorsand wires throughnon-cylinder side. Left HandHinges Left.Open Inward.“LH”Left HandReverse BevelHinges Left.Open Outward“LHRB”Right HandHinges Right.Open Inward.“RH”Right HandReverse BevelHinges Right.Open Outward“RHRB”LH and LH Reverse DoorNormally OpenNormally ClosedONON1    2    3    41    2    3    4RH and RH Reverse DoorNormally OpenNormally ClosedONON1    2    3    41    2    3    4Black circles indicate position of DIP switchFig. 3B
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 9Fig. 5AStep #5 – Outside Escutcheon and Inside Mounting Plate InstallationNOTE: Feed mortise connectors through the corresponding hole on the mounting plate. 1. Attach the mounting plate using (2) 8-32 x 3/8" Phillips at head      undercut combo screws in the upper left and middle right      positions of the mounting plate and (2) 8-32 x 3/8" Phillips at head      screws in the bottom positions (Fig 5A).2. Feed the reader cable located on the back of the outside escutcheon      through the door prep. Remember, the outside gasket must be used      when installing Harmony in an outdoor application (Fig 5B).3. Secure the mounting plate to the outside escutcheon with      (2) #8-32 x 2”at head machine screws (Fig 5C).Fig. 5B(2) 8-32 x 3/8” Phillips Flat Head Undercut Combo Screw(2) 8-32 x 3/8” Phillips Flat Head ScrewGasket required for exterior door applicationsReader CableInside of DoorInside of DoorOutside of DoorStep #6 – Install GasketAdd Gasket (if necessary):Remember to place the inside gasket when  installing in an outdoor application. Gasket ts snug around plate at top and sides,  leaving room for the hole at the bottom. Remove backing and place gasket  on door (Fig. 6A).  Required for exteriordoor applications.Fig.  6AInside of Door
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com10Fig.  8BPosition cylinder so that the SARGENT logo is right-side up.Step #8 – Outside Cylinder Installation1. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 8A).2. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig 8B).3. Use the key to rotate the cylinder clockwise until it is ush at the bottom and the SARGENT logo is right-side up.    Do not attempt to tighten all the way.4. Tighten the cylinder clamp set screw to prevent unscrewing      of the cylinder (Fig 8C).5. Test cylinder function:       70/71 Function: Key retracts latch.      80/81 Function: Key retracts latch and       projects and retracts deadbolt.     Ensure smooth operation of latchbolt       and deadbolt.     NOTE: Use lever handle holes to       manipulate mortise to ease thread         engagement of cylinder.Fig.  8CFig.  8ACylinder Set ScrewPhillips ScrewdriverSARGENTSARGENTCorrect           IncorrectOutside of DoorFig. 7A1(2) #8-32 x 2”Phillips Flat HeadMachine ScrewFig.  7A2 DetailStep #7 – Connect Earth GroundConnect pin-5 green/yellow ground wire ring terminal  to top right screw.
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 11Fig.  10A J1 J2To ElectroLynxHarness J5From ReaderBoard P5 to J5Step #10 – Connect ElectroLynx 1.  Connect P5 (7 Pin Connector) from reader board      to J5 on interior escutcheon PCB assembly (Fig. 10A). 2.  Connect ElectroLynx harness (4 and 8-pin) from door harness       to ElectroLynx harness on interior PCB assembly (Fig. 10A).      NOTES:      Neatly fold the wires onto themselves and into the remaining      space to prevent pinching wires when mounting escutcheon.Do not tuck extra mortise lock body wires back inside the lock    body cylinder hole.      Connectors go on only one way.      Do not offset connector and be sure they are completely seated.PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)J2 J11-Violet Lock Neg(Solenoid, neg)3-PinkDPS (NC)1- BlackPWR NEG3-WhiteDATA 15-OrangeRX (NO/NC)7-Brown EGND2-Gray Lock Pos(Solenoid, pos) 4-TanDPS (COM)2-Red PWR POS4-GreenDATA 06-BlueRX (COM)8-YellowLEDStep #9 – Outside Lever and Inside Adapter Plate Assembly Installation1. With outside lever horizontal, insert the mounting post through outside of door and lock body.    Make certain the lever spindle is properly engaged inside the lock body (Fig 9A).2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 9B).3. Slide inside adapter and plate assembly over      spindle and loosely secure with (2) 8-32 X 5/8”      Phillips oval head and lock washer      machine screws.     Be sure to rotate the set screw hole so      the hole (Studio Collection only) faces     the hinge side and seat the inside     spindle fully into the lock body.4. Securely tighten the lock body screws.Fig.  9BFig.  9AMortiseLock bodyScrew8-32 X 5/8” Phillips Oval Head and Lock WasherMachineScrewMortiseLock bodyScrewInside of DoorOutside of Door
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com12Step #12 – Connector Attachment (Exterior PCB Assembly) 1. Connect P3 (2-pin connector) from lock body      to J3 on module (Fig. 12A). 2. Connect P4 (6-pin connector) from lock body      to J4 on module (Fig. 12A). From Lock Body P3 to J3 From Lock Body P4 to J4Fig.  12A J4 J3Step #11 – Outside Wire PositioningPlease follow these steps prior to installing  inside escutcheon to prevent any damage caused by pinching wires:  1.    Once wires are arranged, position piece         at a rotated angle against the door, under        earth ground wire. 1.  Press piece against door while turning  clockwise (Fig. 11A). 2.  Twist into place, perpendicular with door (Fig. 11B).Inside of DoorFig.  11A Fig.  11BRotate Clockwise
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 13Step #14 – Inside Rose and Inside Lever Assembly Instructions1. Rotate the inside rose - rst counter clockwise to      seat the threads and then, clockwise to securely tighten.2. Slide lever handle onto spindle until fully seated.      Be sure handle is horizontal and facing the hinge side      of the door.      Push lever onto spindle so minimum gap is visible.3. Tighten the set screw securely with 1/8” hex wrench.Fig.  14A Fig. 14BSet ScrewInside LeverSpindleInside of DoorRoseStep #13 – Inside Escutcheon Assembly Installation1. Tighten the inside escutcheon securely to the mounting      plate with the Phillips at head machine screws provided.      Use the 8-32 x 5/8” for the top of the escutcheon      and the 8-32 x 1/4” screws for the bottom of the      escutcheon located under the turn lever.      Remember the inside gasket must be used      when installing Harmony in an outdoor application.2. Be sure the turn assembly is functional      and the deadbolt functions properly.8-32 X 1/4” Phillips Flat Head UndercutMachine Screw8-32 X 5/8” Phillips Flat Head UndercutMachine ScrewFig.  13AInside of Door
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com14Step #15 – Application of Front PlateAttach front plate with (2) 8-32x1/4” at head screws  and tighten securely.Product 8 PIN CONNECTOR 4 PIN CONNECTOR1-Black 2-Red 3-White 4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 9-Violet 10-Gray 11-Pink 12-TanACCESS CONTROL DEVICES: Harmony H2 Mortise, ElectroLynx wire Color / Function assignments12/24VDC (Reader)WIE-GANDWIE-GANDRX RX EGND LED 12/24 VDC(LOCK RELAY)DPS (NC)DPS (COM)SARGENT -HARMONY SERIES,H2 MortiseNEG POS DATA_1 DATA_0 NO/NC  COM REF.*DIA-GRAMSREF.*DIA-GRAMSNEG POS DPS DPSWiring Diagrams8Reader LED ConfigurationThe Harmony Series reader can be congured for (3) modes of LED operation.  HID Programming cards are also supported to congure the behavior for LED  color activity. Call 1-800-WIRE for details. Mode 1:• Red LED ‘ON’ when powered.• Presenting a 13.56MHz credential causes LED to ‘FLICKER’     green and return to red state.• Reference *Diagram #1 as a function of power      requirement (12VDC or 24VDC).   Note: LED wire is unconnected.Mode 2:• Green LED “ON” when powered.• No Flicker after presenting valid 13.56MHz credential.• Reference *Diagram #2 as a function of power     requirement (12VDC or 24VDC).   Note: LED wire must be connected to circuit GROUND of the system’s power supply. PIN8 (Yellow – LED)PIN 6 (Blue – RX COM)PIN 4 (Green – Data 0)PIN 2 (Red – Reader POS)PIN 1 (Black – Reader NEG)PIN 3 (White – Data 1)PIN 5 (Orange – RX NO/NC)PIN 7 (Brown-EGND)PIN 4 (Tan – DPS COM)PIN 2 (Gray – Lock POS)PIN 1 (Violet – Lock NEG)PIN 3 (Pink – DPS NC)Fig.  135(2) 8-32x1/4” Flat Head ScrewsLock Body ScrewLock Body ScrewOutside of DoorMode 3:• EAC Panel controls LED operation.• Reference *Diagram #3 as a function of power requirement (12VDC or 24VDC).   Note: Control of LED is a function of the EAC panel equipment (ie. relay) to toggle between green and red.   Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader     performance will be interfered (*Diagram #3).*Diagrams on following pages
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 15Typical Harmony Mortise Lock Application Diagram (12/24VDC Lock)12/24VDC SYSTEM• Reader Draw = 125mA• 12VDC Solenoid Draw = 500mA• 12VDC Total Current Draw = 625mA• 24VDC Solenoid Draw = 250mA• 24VDC Total Current Draw = 375mADIAGRAM #1 – MODE 1: RED LED ‘ON’ WHEN POWEREDBlack (Hot)    White (Neutral)         Green (Gnd)Power Supply(By Others)Harmony Series H2Requires 12 or 24VDCElectronic Access Control Panel (By Others)Use (NC) for FailSafe OperationLock Relay(NO) Fail Secure OperationDPS DPSDATA 1DATA 0RXRXREADER NEG - Black, 1READER POS - Red, 2DATA 1 - White, 3DATA 0 - Green, 4RX (NO/NC) - Orange, 5RX (COM) - Blue, 6*EGND - Brown, 7LED - Yellow, 8LOCK NEG - Violet, 9LOCK POS - Gray, 10DPS (NC) - Pink, 11DPS (COM) - Tan, 12Not Used H2 HarmonyMortise Lock120 VACInput 12/24VDCH    N    G-    +*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.  Failure to follow proper ESD safe grounding procedures could lead to equipment failure. 12 ConductorElectroLynx HarnessFrom McKinneyQC12 Electric HingeFrom McKinney
Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.06/30/09Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com16Typical Harmony Mortise Lock Application Diagram (12/24VDC Lock)DIAGRAM #2 – MODE 2: GREEN LED ‘ON’ WHEN POWEREDBlack (Hot)    White (Neutral)         Green (Gnd)Power Supply(By Others)Electronic Access Control Panel (By Others)Use (NC) for FailSafe OperationLock Relay(NO) Fail Secure OperationDPS DPSDATA 1DATA 0RXRXREADER NEG - Black, 1READER POS - Red, 2DATA 1 - White, 3DATA 0 - Green, 4RX (NO/NC) - Orange, 5RX (COM) - Blue, 6*EGND - Brown, 7LED - Yellow, 8LOCK NEG - Violet, 9LOCK POS - Gray, 10DPS (NC) - Pink, 11DPS (COM) - Tan, 12120 VACInput 12/24VDCH    N    G-    +Harmony Series H2Requires 12 or 24VDCH2 HarmonyMortise Lock*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.  Failure to follow proper ESD safe grounding procedures could lead to equipment failure. 12/24VDC SYSTEM• Reader Draw = 125mA• 12VDC Solenoid Draw = 500mA• 12VDC Total Current Draw = 625mA• 24VDC Solenoid Draw = 250mA• 24VDC Total Current Draw = 375mA12 ConductorElectroLynx HarnessFrom McKinneyQC12 Electric HingeFrom McKinney
06/30/09 Copyright © 2009 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.Harmony Series H2 Mortise LockA8027A • 800-810-WIRE (9473) • www.sargentlock.com 17Typical Harmony Mortise Lock Application Diagram (12/24VDC Lock)DIAGRAM #3 – MODE 3: EAC PANEL CONFIGURABLEBlack (Hot)    White (Neutral)         Green (Gnd)Power Supply(By Others)Electronic Access Control Panel (By Others)Lock Relay(NO) Fail Secure OperationDPS DPSDATA 1DATA 0RXRXLEDREADER NEG - Black, 1READER POS - Red, 2DATA 1 - White, 3DATA 0 - Green, 4RX (NO/NC) - Orange, 5RX (COM) - Blue, 6*EGND - Brown, 7LED - Yellow, 8LOCK NEG - Violet, 9LOCK POS - Gray, 10DPS (NC) - Pink, 11DPS (COM) - Tan, 12120 VACInput 12/24VDCH    N    G-    +Use (NC) for FailSafe OperationHarmony Series H2Requires 12 or 24VDCH2 HarmonyMortise Lock*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.  Failure to follow proper ESD safe grounding procedures could lead to equipment failure. 12/24VDC SYSTEM• Reader Draw = 125mA• 12VDC Solenoid Draw = 500mA• 12VDC Total Current Draw = 625mA• 24VDC Solenoid Draw = 250mA• 24VDC Total Current Draw = 375mA12 ConductorElectroLynx HarnessFrom McKinneyQC12 Electric HingeFrom McKinney
A8027A-06/30/09SARGENT100 Sargent DriveNew Haven, CT 06511 USA800-481-8464 •  www.sargentlock.comFounded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience.For 82280-82283 & 82270-82273 Function mortise locks with cylinders:1. Insert key into cylinder and rotate: There should be no friction against     lock case, wire harness or any other obstructions.2. The key will retract the latch: Key should rotate freely.3. When the deadbolt is thrown: Ensure that the key retracts both the     deadbolt and the latch.4. Inside lever: When used, ensure it retracts both the latch      and deadbolt (if provided).5. Close door: Ensure latch and deadbolt fully extend      and do not bind.Mechanical Operational Check9Note: Once electrical wiring has been successfully completed according to proper application, follow the following step:1. Turn power ON.2. Verify LED located on reader is ON - red or green,      depending on reader conguration (see reader LED    configuration). 3. Present credential and verify LED and sounder activity.4. Verify valid card read at EAC Panel. 5. Verify system operation functions; i.e., when credential       is presented to reader that the door unlocks. Electrical Operational Check10

Navigation menu