ASSALOY SCYPROX5 Microprocessor Controlled Network Lock User Manual 12 0305 Exhibit Cover
ASSA ABLOY Inc. Microprocessor Controlled Network Lock 12 0305 Exhibit Cover
ASSALOY >
Manual
Certification Exhibit FCC ID: U4A-SCYPROX5 IC: 6982A-SCYPROX5 FCC Rule Part: 15.209, 15.249 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0305 Manufacturer: Assa Abloy Model: C2-PA/PK Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 in ar IN100 im with Aperio™ Technology Pr el Mortise Lock Installation Instructions A8122B 8/12 Copyright 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. These installation instructions include Microsoft® Tags that you can scan to view videos of certain installation steps. The Microsoft Tag mobile app is required to scan the Tags. Download the free mobile app at http://gettag.mobi Table of Contents Warning Changes or modifications to this device not expressly approved by ASSA ABLOY could void the user’s authority to operate the equipment. ar Warning . ..................................................................................2 General Description..................................................................3 Specifications...........................................................................3 System Overview......................................................................3 Parts Breakdown......................................................................4 Lock Installation.......................................................................6 Maintenance ..........................................................................15 Operational Check .................................................................16 Lock LED Indications . ...........................................................17 FCC: 8/05/12 im • Consult the dealer or an experienced radio/TV technician for help. Pr el Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. in This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Industry Canada: This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. “This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.” Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. 1-800-810-WIRE • www.sargentlock.com • A8122B IN100 Mortise Lock General Description The SARGENT® IN100 mortise lock with Aperio™ Technology makes it easy and cost-effective to bring access control to doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The IN100 utilizes HID® iCLASS® 13.56 MHz smart card technology and all technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1 hardware. This product is operated by six (6) “AA” alkaline batteries. SARGENT mortise locks are designed with quality components to provide high security, performance, and durability. The IN100 mortise lock may be used for both indoor and exterior applications. A weather-protective gasket is required for exterior applications. Specifications Credential Support • • • HID 13.56 MHz iCLASS (full authentication, all formats • HID 125 kHz prox IEEE 802.15.4 UHF interface AES 128 bit encryption in Electronic Access Control System Access Control Panel TCP/IP Aperio Hub Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. RS-485/Wiegand Pr el im When a user presents a supported credential to the lock, the Aperio system is designed to send the credential wirelessly to the Aperio Hub. The Aperio Hub (wired through RS-485 or Wiegand) then communicates with an EAC (Electronic Access Control) system. The EAC system provides the access decision to the Aperio Hub where access to the lock is either granted or denied. IEEE 802.15.4 (2.4GHz) IN100 Patent Pending To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only. Warning: SARGENT Mfg. Co. IN100 locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications. 1-800-810-WIRE • www.sargentlock.com • A8122B 8/05/12 System Overview Lock ar IN100 Mortise Lock Parts Breakdown 13.56 MHz iCLASS & 125kHz Prox 1* ar 1* im in 10 8/050/12 Pr el Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 19 18 17 16 21 20 21 21 19 * Patent pending 15 Tools Required: 15 13 14 1-800-810-WIRE • www.sargentlock.com • A8122B • #2 Phillips screwdriver • Flat head • T20 Torx Driver • Security allen wrench (provided) IN100 Mortise Lock Parts Breakdown 13.56 MHz iCLASS & 125kHz Prox (Continued) QTY. Reader Assembly* 52-5359 Incepta Electronic Replacement Pack, iCLASS only, IA-C2, 7976 52-5360 Incepta Electronic Replacement Pack, iCLASS only, IA-C2 , 7977 52-5361 Incepta Electronic Replacement Pack, iCLASS only, IA-C2 , 7978 52-5362 Incepta Electronic Replacement Pack, iCLASS only, IA-C2 , 7979 52-5363 Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7976 52-5364 Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7977 52-5365 Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7978 52-5366 Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7979 52-1332 Gasket (Optional) 52-2847 Conduit Pack (Optional) 52-1370 Fire Shield* 52-1327 Mounting Plate 52-4488 Screw Pack 01-0898 AA battery 52-4483 Inside Cover Assembly 52-4321 Door Position Switch Pack 10 A8120 Field Prep Template (not shown) 11 4697 Door Manufacturers Template (not shown) 12 A8122 Instructions (not shown) 13 C2-7976-hand-finish Lock body with dead bolt with Cylinder 15 16 ar in C2-7978-hand-finish Lock body without dead bolt with Cylinder C2-7979-hand-finish Lock body without dead bolt without Cylinder 79-0035 Without dead bolt 79-0036 With dead bolt (shown) 77-4236 Mortise Screw Pack - Specify Finish (Includes: Wood and Metal Lock body Screws, Faceplate Screws, and Strike Screws) #41 Mortise Cylinder Consult Factory Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 14 Lock body with dead bolt without Cylinder Pr el C2-7977-hand-finish 52-4481 im DESCRIPTION PART NO. 17 13-2131 97 Ring 18 77-4081 130W Turn Lever 19 Consult Factory Reference Incepta Catalog 20 78-3696 O-rose 21 79-2162 Trim Pack * Patent Pending 1-800-810-WIRE • www.sargentlock.com • A8122B 8/05/12 ITEM IN100 Mortise Lock Lock Installation 1 Prepare Door A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. LHRB RH RHRB Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A in B. Door Preparation ar LH Left Hand Hinges Left Open Inward Prior to installation, all holes must be free of burrs, debris and sharp edges. Pr el Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. im Prepare door according to appropriate template (see website www.intelligentopenings.com). • Field Template: A8120 (ships with product) • Door Manufacture’s Template: 4697 Outside of Door Ribbon Cable Hole External DPS Hole Inside of Lock body Wire Hole Outside Cylinder Hole (only with cylinder installation) Thumb Turn Lever Hole Mortised Pocket 8/050/12 Fig. 1B Ribbon Cable Hole Through-bolt Hole Through-bolt Hole Lever Handle Hole Inside of Door 1-800-810-WIRE • www.sargentlock.com • A8122B Lever Handle Hole IN100 Mortise Lock 2 How to Change Hand of Lock body A. Reverse Lock Hand 1. Position lock body so the red surface of the locking piece is visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece. 3. Push locking piece toward the back of the lock body and rotate the locking piece 180°. Note: Red indicates locked (outside) side. B. Reverse Latch Hand 1. Rotate the latchbolt 180°. Locking piece Fig. 2A Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Locking piece Fig. 2B Outside of Door 3 Install Door Position Switch (DPS) 1. Insert DPS into the raceway on the latch edge of the door. 2. Push wires through raceway toward lock prep. For hollow metal doors with a conduit installed, route DPS wire to the same preparation hole as the cylinder hole. Door Position 3. Push DPS firmly into place by hand. Switch (DPS) Note: DO NOT TAP SWITCH WITH ANY TOOL. 4. Install magnet into door frame. Push firmly into place by hand. See A7983A. 5. To connect DPS to lock controller per diagram, refer to the wiring in Step #14 section 3. Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi Note: Alternate routing for hollow metal doors when using optional weather conduit, p/n 52-2847. Fig. 3 1-800-810-WIRE • www.sargentlock.com • A8122B 8/05/12 Pr el im in ar 2. Flip deadlatch by hand to match bevel of latchbolt. IN100 Mortise Lock 4 Weather Conduit Installation (Optional P/N 52-2847) Install weather conduit on NON FIRE-RATED metal exterior doors only (Fig. 4A). 1. Carefully insert the weather conduit into the ribbon cable hole from the outside of the door. 2. Place the O-ring around the weather conduit on the inside and up against the door (Fig. 4B). Inside of Door O-Ring Fig. 4B 1. Feed the wire harness through the mortise pocket and inside preparation hole as depicted in Fig. 5. Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 8/050/12 im 5 Install Lock body in ar Fig. 4A Pr el 2. Carefully push the lock body into the pocket while lightly applying tension to the wire harness. Note: Do not pull the lock into the pocket with the harness alone. Ensure that the wire harness is not pinched between the lock and the mortise pocket. Inside of Door Mortise Connectors 3. Insert (2) #12-24 screws into the lock body and tighten with a screw driver. (2) #12-24 screws Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi 1-800-810-WIRE • www.sargentlock.com • A8122B Fig. 5 IN100 Mortise Lock 6 Attach Front Plate Outside of Door Attach front plate with (2) flat head screws. Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi Pr el Make certain the lever spindle is properly engaged inside the lock body (Fig 7A). 2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 7B). 3. Slide inside adapter and plate assembly over spindle and secure with (2) 8-32 X 5/8” Phillips oval head and lock washer machine screws. Outside of Door Assemble Trim Inside of Door 8-32 X 5/8” Phillips Oval Head and Lock Washer Machine Screw Inside Lever Assembly Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 1. With outside lever horizontal, insert the mounting post through outside of door and lock body. Outside Trim Fig. 7A Fig. 7B 1-800-810-WIRE • www.sargentlock.com • A8122B 8/05/12 7 Assemble Trim Fig. 6 im in ar (2) flat head screws IN100 Mortise Lock 8 Install Inside Rose and Inside Lever Assembly 1. Rotate the inside rose first counter clock wise to seat the threads then clockwise to securely tighten. Inside of Door 2. Slide lever handle onto spindle until fully seated. Be sure handle is horizontal and facing the hinge side of the door. Push lever onto spindle so minimum gap is visible. Spindle 3. Tighten the set screw securely with a T20 Torx. Rose 4. Before closing the door, test that the lever is functional and ensure smooth operation of the latchbolt. ar Set Screw Inside Lever Fig. 8A in 9 Outside Cylinder Installation Fig. 8B 1. Slide the spring and the rosette onto the cylinder. im 2. Rotate the cylinder into cylinder hole with fingers. 8/050/12 Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole. Note: Do not attempt to tighten all the way. 4. Verify the orientation of the cylinder has the Sargent logo as depicted in Fig. 9A. Pr el 5. Hand tighten the cylinder clamp screw with Phillips screwdriver to prevent unscrewing of the cylinder (Fig 9C). 6. Test cylinder function: • Key retracts latchbolt and deadbolt (7976 function). Key retracts latchbolt (7978 function). • Cylinder not present for 7977 and 7979 functions. Outside of Door NOTE: Use lever handle holes to manipulate lock to ease thread engagement of cylinder. Rosette IMPORTANT: Position cylinder so that the SARGENT logo is positioned correctly. Spring Phillips Screwdriver Cylinder Correct Incorrect Cylinder ClampScrew Fig. 9A Fig. 9B Fig. 9C 10 1-800-810-WIRE • www.sargentlock.com • A8122B IN100 Mortise Lock Inside of Door 10 Install Thumb Turn 1. Insert thumb turn into preparation hole and engage slot in lock body. 2. Orient mounting plate so screw hole is vertical (aligned with preparation holes). 3. Secure plate with phillips screw provided. 4. Test thumb turn for function by retracting and projecting the deadbolt (7976 and 7977 functions only). Phillips screw ar Fig. 10 in Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi Thumb Turn 11 Inside Mounting Plate Installation Mounting Plate Fig. 11A Fire shield Inside of Door 2x Through bolts open slot Fig. 11B Fig. 11C Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi 1-800-810-WIRE • www.sargentlock.com • A8122B 11 Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 2x Through bolts 8/05/12 Pr el im 1. Install washers onto both through bolts, Fig. 11A. Insert the through bolts through the upper and lower holes of the mounting plate. 2. Feed the DPS wire through the hole of the fire shield and feed the lock wiring into the slot, Fig. 11B. 3. Place the fire shield against the door and place the mounting plate over it so the through bolts align with the door holes. IN100 Mortise Lock 12 Gasket Installation (Optional P/N 52-1332) Gasket required for exterior doors (not required for fire rating). Figure 12. 1. Place the gasket on the on the reader posts and ensure the shape is aligned with the edge of the reader. Fig. 12 1. Orient the reader so the HID logo is at the bottom and the lens is at the top. 2. Feed the ribbon cable through the door (from out side to inside). 3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes. Hold the reader in position with hand. 4. While gently pressing upward on the outside reader, tighten the (2) through bolts on the inside of the door to secure the reader. Pr el Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 8/050/12 im 13 Outside Reader Installation in ar Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi Outside of Door Inside of Door HID Reader Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi 12 1-800-810-WIRE • www.sargentlock.com • A8122B Fig. 13A Fig. 13B IN100 Mortise Lock 14 Configuring RX Switch Handing Inside of Door 1. Each lever handle has a sensor installed but only the inside lever is utilized for RX sensing. 2. To properly configure the RX functionality, connect the terminals as indicated below: RH or RHRB door handing (blue to blue) LH or LHRB door handing (yellow to blue) 3. Note: Factory default is blue to blue (right hand lock). IMPORTANT: grasp each connector firmly before separating. Do not pull wires apart. DPS Lock body wiring ar Wire harness DPS Lock body wiring Pr el im 1. Connect the outside reader ribbon cable to the top of the battery housing (See Fig.15B for detail). 2. Connect the DPS wire to the 3-wire header at the lower left corner of the PCB. 3. Connect the lock body harness to the 5-wire header at the lower right corner of the PCB. IMPORTANT: Confirm the correct connector orientation prior to assembly. Do not force connectors Note: If the HID wire harness must be twisted to connect to the battery housing the HID reader has been installed upside down. Turn the HID reader right side up and reinstall, then connect. Fig. 14 Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 15 Battery Housing Wiring in Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi Wire harness Fig. 15A 1-800-810-WIRE • www.sargentlock.com • A8122B 13 8/05/12 Fig. 15B IN100 Mortise Lock 16 Battery Housing Installation Inside of Door 1. Position the DPS and harness below the tabs of the mounting plate. 2. Align the tabs of the battery housing with the tabs of the mounting plate. Push down. 3. Lightly press the lock harness to assemble. 4. Snap battery compartment into position. 8/050/12 im Fig. 16 Pr el Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. in ar Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi Inside of Door 17 Battery Installation 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly. 2. After batteries are installed an audible “beep” will sound, the lock motor will cycle. Refer to page 18, section “Lock Self Test LED Indication”, for proper power up LED indications. Scan this Microsoft® Tag using your mobile phone to see a video of this installation step. The Microsoft Tag mobile app is required to scan the Tag. Download the free mobile app at http://gettag.mobi 14 1-800-810-WIRE • www.sargentlock.com • A8122B Fig. 17 IN100 Mortise Lock 18 Inside Cover Installation 1. Assemble cover by hooking top edge on inside mounting plate. 2. Carefully press bottom of cover toward door without pinching any wires. 3. Secure the cover utilizing a 1/8” security Allen wrench. Inside of Door Inside Cover Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. For battery replacement: When replacing the (6) “AA” alkaline batteries in the compartment, please note batteries must be replaced within 5 minutes to prevent the internal clock from becoming inaccurate. 1-800-810-WIRE • www.sargentlock.com • A8122B 15 8/05/12 Maintenance Pr el Fig. 18 im in ar 1/8” Security Allen Screw IN100 Mortise Lock Operational Check For 7976- and 7978-function mortise locks with cylinders: 1. Insert key into cylinder and rotate. There should be no friction against lock case, wire harness or any other obstructions. 2. Check that the key retracts the latch: the key should rotate freely. 3. Throw the deadbolt (if present): Check that the key retracts both the deadbolt and the latch. 8/050/12 Pr el Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. im in ar 5. Present a valid iCLASS or 125 kHz prox credential to unlock outside lever and retract latch. Note: The credential should approach the inscription on the reader as indicated to ensure the credential is read properly. Do not wave credential. 4. Try the inside lever: Ensure it retracts latch and deadbolt (if provided). 16 1-800-810-WIRE • www.sargentlock.com • A8122B IN100 Mortise Lock Lock LED Indications 1 Lock Normal Operation LED indication The lock has three LEDs that support an optical scheme with red, yellow and green. The indication scheme is described by the figures below: Card read (configurable) One yellow flash (.25 seconds) Access granted, EAC offline or online One green flash (1 second) Access denied, EAC online One red flash (1 second) Access denied, EAC offline Three red flashes (.5 second each) Lock mechanism is blocked when closing ar Continuous red flashes blocked when closing (.125 seconds every 1 second) Time to replace the battery im Battery reached end of life, lock disabled in Error in lock, maintenance required Ten red flashes (.125 seconds each), maintenance required; repeated if lock can’t close Continuous yellow flashes (.25 seconds every 5 seconds) Fig. Lock Normal operation LED indication Continuous red flashes, (.25 seconds every 5 Pr el NOTE: Ensure the tamper switch activator does not fall out of the cover during assembly. A tamper event message will be sent to the EAC panel if tamper is enabled. The “Error in lock” indication is also shown instead of the POST flashes if the battery is not accepted as new after a power-on-reset. 2 Lock Maintenance LED Indication Some special LED indication schemes are used during lock maintenance actions: Enter configuration mode Five yellow flashes (.125 seconds each) Fig. Lock maintenance LED indication 1-800-810-WIRE • www.sargentlock.com • A8122B 17 8/05/12 Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. seconds) IN100 Mortise Lock 3 Lock Self Test LED Indication After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as is described by the figure below: One red, one green flash (1 second each) Good POST Bad POST One red flash followed by 16 red or green flashes (.5 seconds each) The “Error in lock” indication is also shown instead of the POST flashes if the battery is not accepted as new after a power-on-reset. 10 red flashes. Fig. Lock POST LED indication 8/050/12 Meaning if Red Main board firmware corrupt Override list corrupt Code in Event Log 0x0001 in 0x0002 Production data corrupt 0x0004 Security data corrupt 0x0008 Configuration data corrupt 0x0010 Battery power low 0x0020 RFID reader circuit error 0x0040 Voltage regulator error 0x0080 im Pr el Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Blink ar The first flash is always red. If the POST fails, the color of the 16 trailing flashes indicate the status of each individual test as described by the following table: 10 Card detection circuit error 0x0100 11 Secure area communication error 0x0200 12 Secure area memory corrupt 0x0400 13 Secure area sensor or motor error 0x0800 14 Radio modem communication error 0x1000 15 Radio modem memory corrupt 0x2000 16 Radio modem configuration error 0x4000 17 Radio modem RF circuit error 0x8000 NOTE: If the battery is not accepted as new after a power on reset, no POST is performed. Instead, the 10 quick red flashes used to indicate Error in lock is shown. 18 1-800-810-WIRE • www.sargentlock.com • A8122B Pr el im in ar Notes The global leader in door opening solutions y ar in im Pr el SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A8122B - 8/12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 21 XMP Toolkit : 3.1-701 Producer : ScanSoft PDF Create! 7 Creator Tool : Microsoft Word - 12-0305 - Exhibit Cover Create Date : 2012:08:10 10:53:48-04:00 Modify Date : 2012:08:10 10:53:54-04:00 Title : Microsoft Word - 12-0305 - Exhibit Cover Creator : courtney.merrick Author : courtney.merrickEXIF Metadata provided by EXIF.tools