ASSALOY SCYPROX5 Microprocessor Controlled Network Lock User Manual 12 0305 Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Network Lock 12 0305 Exhibit Cover

Manual

Download: ASSALOY SCYPROX5 Microprocessor Controlled Network Lock User Manual 12 0305   Exhibit Cover
Mirror Download [FCC.gov]ASSALOY SCYPROX5 Microprocessor Controlled Network Lock User Manual 12 0305   Exhibit Cover
Document ID1767836
Application IDRdD4879Bw7EdvgyFcy2ZiA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize218.5kB (2731271 bits)
Date Submitted2012-08-16 00:00:00
Date Available2012-08-16 00:00:00
Creation Date2012-08-10 10:53:48
Producing SoftwareScanSoft PDF Create! 7
Document Lastmod2012-08-10 10:53:54
Document TitleMicrosoft Word - 12-0305 - Exhibit Cover
Document CreatorMicrosoft Word - 12-0305 - Exhibit Cover
Document Author: courtney.merrick

Certification Exhibit
FCC ID: U4A-SCYPROX5
IC: 6982A-SCYPROX5
FCC Rule Part: 15.209, 15.249
IC Radio Standards Specification: RSS-210
ACS Project Number: 12-0305
Manufacturer: Assa Abloy
Model: C2-PA/PK
Manual
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
in
ar
IN100
im
with Aperio™
Technology
Pr
el
Mortise Lock
Installation Instructions
A8122B
8/12
Copyright 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
These installation instructions include Microsoft® Tags that you can
scan to view videos of certain installation steps. The Microsoft Tag
mobile app is required to scan the Tags. Download the free mobile
app at http://gettag.mobi
Table of Contents
Warning
Changes or modifications to this device not expressly approved by ASSA ABLOY
could void the user’s authority to operate the equipment.
ar
Warning . ..................................................................................2
General Description..................................................................3
Specifications...........................................................................3
System Overview......................................................................3
Parts Breakdown......................................................................4
Lock Installation.......................................................................6
Maintenance ..........................................................................15
Operational Check .................................................................16
Lock LED Indications . ...........................................................17
FCC:
8/05/12
im
•
Consult the dealer or an experienced radio/TV technician for help.
Pr
el
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
in
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Industry Canada:
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des
règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum
(or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other
users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is
not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne
d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire
les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son
gain de sorte que la
puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une
communication satisfaisante.
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening,
and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in
any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a
new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to
ensure compliance with all applicable codes and ratings.
1-800-810-WIRE • www.sargentlock.com • A8122B
IN100 Mortise Lock
General Description
The SARGENT® IN100 mortise lock with Aperio™ Technology makes it easy and cost-effective to bring access control to doors. It uses local wireless communication between the lock and an Aperio hub to connect
to an access control system, eliminating the greatest cost and inconvenience of traditional access control
– the wiring at the door. The IN100 utilizes HID® iCLASS® 13.56 MHz smart card technology and all technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1 hardware.
This product is operated by six (6) “AA” alkaline batteries. SARGENT mortise locks are designed with quality
components to provide high security, performance, and durability.
The IN100 mortise lock may be used for both indoor and exterior applications. A weather-protective
gasket is required for exterior applications.
Specifications
Credential Support
•
•
•
HID 13.56 MHz iCLASS (full authentication, all formats
•
HID 125 kHz prox
IEEE 802.15.4 UHF interface
AES 128 bit encryption
in
Electronic Access
Control System
Access Control Panel
TCP/IP
Aperio Hub
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
RS-485/Wiegand
Pr
el
im
When a user presents a supported credential to
the lock, the Aperio system is designed to send
the credential wirelessly to the Aperio Hub. The
Aperio Hub (wired through RS-485 or Wiegand)
then communicates with an EAC (Electronic
Access Control) system. The EAC system provides
the access decision to the Aperio Hub where
access to the lock is either granted or denied.
IEEE 802.15.4
(2.4GHz)
IN100 Patent
Pending
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
Warning: SARGENT Mfg. Co. IN100 locksets utilizing a door position switch (DPS) are not rated for, or intended
for use in life safety applications.
1-800-810-WIRE • www.sargentlock.com • A8122B
8/05/12
System Overview
Lock
ar
IN100 Mortise Lock
Parts Breakdown
13.56 MHz iCLASS & 125kHz Prox
1*
ar
1*
im
in
10
8/050/12
Pr
el
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
19
18
17
16
21
20
21
21
19
* Patent pending
15
Tools Required:
15
13
14
1-800-810-WIRE • www.sargentlock.com • A8122B
•
#2 Phillips screwdriver
•
Flat head
•
T20 Torx Driver
•
Security allen wrench
(provided)
IN100 Mortise Lock
Parts Breakdown 13.56 MHz iCLASS & 125kHz Prox (Continued)
QTY.
Reader Assembly*
52-5359
Incepta Electronic Replacement Pack, iCLASS only, IA-C2, 7976
52-5360
Incepta Electronic Replacement Pack, iCLASS only, IA-C2 , 7977
52-5361
Incepta Electronic Replacement Pack, iCLASS only, IA-C2 , 7978
52-5362
Incepta Electronic Replacement Pack, iCLASS only, IA-C2 , 7979
52-5363
Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7976
52-5364
Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7977
52-5365
Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7978
52-5366
Incepta Electronic Replacement Pack, Prox only, PA-C2 , 7979
52-1332
Gasket (Optional)
52-2847
Conduit Pack (Optional)
52-1370
Fire Shield*
52-1327
Mounting Plate
52-4488
Screw Pack
01-0898
AA battery
52-4483
Inside Cover Assembly
52-4321
Door Position Switch Pack
10
A8120
Field Prep Template (not shown)
11
4697
Door Manufacturers Template (not shown)
12
A8122
Instructions (not shown)
13
C2-7976-hand-finish
Lock body with dead bolt with Cylinder
15
16
ar
in
C2-7978-hand-finish
Lock body without dead bolt with Cylinder
C2-7979-hand-finish
Lock body without dead bolt without Cylinder
79-0035
Without dead bolt
79-0036
With dead bolt (shown)
77-4236
Mortise Screw Pack - Specify Finish (Includes: Wood and Metal
Lock body Screws, Faceplate Screws, and Strike Screws)
#41 Mortise Cylinder
Consult Factory
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
14
Lock body with dead bolt without Cylinder
Pr
el
C2-7977-hand-finish
52-4481
im
DESCRIPTION
PART NO.
17
13-2131
97 Ring
18
77-4081
130W Turn Lever
19
Consult Factory
Reference Incepta Catalog
20
78-3696
O-rose
21
79-2162
Trim Pack
* Patent Pending
1-800-810-WIRE • www.sargentlock.com • A8122B
8/05/12
ITEM
IN100 Mortise Lock
Lock Installation
1 Prepare Door
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
LHRB
RH
RHRB
Left Hand
Reverse Bevel
Hinges Left
Open Outward
Right Hand
Hinges Right
Open Inward
Right Hand
Reverse Bevel
Hinges Right
Open Outward
Fig. 1A
in
B. Door Preparation
ar
LH
Left Hand
Hinges Left
Open Inward
Prior to installation, all holes must be free of burrs, debris and sharp edges.
Pr
el
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
im
Prepare door according to appropriate template (see website www.intelligentopenings.com).
• Field Template: A8120 (ships with product)
• Door Manufacture’s Template: 4697
Outside of Door
Ribbon Cable Hole
External DPS
Hole
Inside of Lock body
Wire Hole
Outside Cylinder Hole
(only with cylinder
installation)
Thumb Turn Lever Hole
Mortised
Pocket
8/050/12
Fig. 1B
Ribbon Cable Hole
Through-bolt Hole
Through-bolt Hole
Lever Handle Hole
Inside of Door
1-800-810-WIRE • www.sargentlock.com • A8122B
Lever Handle Hole
IN100 Mortise Lock
2 How to Change Hand of Lock body
A. Reverse Lock Hand
1. Position lock body so the red surface of the locking piece is visible.
2. Insert blade type screwdriver into locking piece slot to rotate
locking piece.
3. Push locking piece toward the back of the lock
body and rotate the locking piece 180°.
Note: Red indicates locked (outside) side.
B. Reverse Latch Hand
1. Rotate the latchbolt 180°.
Locking piece
Fig. 2A
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Locking piece
Fig. 2B
Outside of Door
3 Install Door Position Switch (DPS)
1. Insert DPS into the raceway on the latch edge of the door.
2. Push wires through raceway toward lock prep.
For hollow metal doors with a conduit installed, route DPS wire to
the same preparation hole as the cylinder hole.
Door Position
3. Push DPS firmly into place by hand.
Switch (DPS)
Note: DO NOT TAP SWITCH WITH ANY TOOL.
4. Install magnet into door frame. Push firmly into place by hand.
See A7983A.
5. To connect DPS to lock controller per diagram, refer to the wiring in
Step #14 section 3.
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
Note: Alternate routing for
hollow metal doors when
using optional weather
conduit, p/n 52-2847.
Fig. 3
1-800-810-WIRE • www.sargentlock.com • A8122B
8/05/12
Pr
el
im
in
ar
2. Flip deadlatch by hand to match bevel of latchbolt.
IN100 Mortise Lock
4 Weather Conduit Installation (Optional P/N 52-2847)
Install weather conduit on NON FIRE-RATED metal exterior doors only (Fig. 4A).
1. Carefully insert the weather conduit into the ribbon cable hole
from the outside of the door.
2. Place the O-ring around the weather conduit on the inside and
up against the door (Fig. 4B).
Inside of Door
O-Ring
Fig. 4B
1. Feed the wire harness through the mortise pocket
and inside preparation hole as depicted in Fig. 5.
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
8/050/12
im
5 Install Lock body
in
ar
Fig. 4A
Pr
el
2. Carefully push the lock body into the pocket while lightly
applying tension to the wire harness.
Note: Do not pull the lock into the pocket with the
harness alone. Ensure that the wire harness is not
pinched between the lock and the mortise pocket.
Inside of Door
Mortise
Connectors
3. Insert (2) #12-24 screws into the lock body
and tighten with a screw driver.
(2) #12-24 screws
Scan this Microsoft® Tag using your mobile phone to
see a video of this installation step. The Microsoft Tag
mobile app is required to scan the Tag. Download the
free mobile app at http://gettag.mobi
1-800-810-WIRE • www.sargentlock.com • A8122B
Fig. 5
IN100 Mortise Lock
6 Attach Front Plate
Outside of Door
Attach front plate with (2) flat head screws.
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
Pr
el
Make certain the lever spindle is properly engaged inside the lock body (Fig 7A).
2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 7B).
3. Slide inside adapter and plate assembly over spindle and secure with (2) 8-32 X 5/8” Phillips
oval head and lock washer machine screws.
Outside of Door
Assemble Trim
Inside of Door
8-32 X 5/8”
Phillips
Oval
Head and
Lock
Washer
Machine
Screw
Inside Lever
Assembly
Scan this Microsoft® Tag using your
mobile phone to see a video of this
installation step. The Microsoft Tag
mobile app is required to scan the
Tag. Download the free mobile app at
http://gettag.mobi
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1. With outside lever horizontal, insert the mounting post through outside of door and lock body.
Outside Trim
Fig. 7A
Fig. 7B
1-800-810-WIRE • www.sargentlock.com • A8122B
8/05/12
7 Assemble Trim
Fig. 6
im
in
ar
(2) flat head screws
IN100 Mortise Lock
8 Install Inside Rose and Inside Lever Assembly
1. Rotate the inside rose first counter clock
wise to seat the threads then clockwise
to securely tighten.
Inside of Door
2. Slide lever handle onto spindle until fully
seated. Be sure handle is horizontal and
facing the hinge side of the door. Push
lever onto spindle so minimum gap
is visible.
Spindle
3. Tighten the set screw securely with
a T20 Torx.
Rose
4. Before closing the door, test that the
lever is functional and ensure
smooth operation of the
latchbolt.
ar
Set Screw
Inside Lever
Fig. 8A
in
9 Outside Cylinder Installation
Fig. 8B
1. Slide the spring and the rosette onto the cylinder.
im
2. Rotate the cylinder into cylinder hole with fingers.
8/050/12
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole.
Note: Do not attempt to tighten all the way.
4. Verify the orientation of the cylinder has the Sargent logo as depicted in Fig. 9A.
Pr
el
5. Hand tighten the cylinder clamp screw with Phillips screwdriver
to prevent unscrewing of the cylinder (Fig 9C).
6. Test cylinder function:
•
Key retracts latchbolt and deadbolt
(7976 function). Key retracts latchbolt
(7978 function).
•
Cylinder not present for 7977
and 7979 functions.
Outside of Door
NOTE: Use lever handle holes
to manipulate lock to ease
thread engagement of cylinder.
Rosette
IMPORTANT: Position cylinder so that the
SARGENT logo is positioned correctly.
Spring
Phillips
Screwdriver
Cylinder
Correct
Incorrect
Cylinder
ClampScrew
Fig. 9A
Fig. 9B
Fig. 9C
10
1-800-810-WIRE • www.sargentlock.com • A8122B
IN100 Mortise Lock
Inside of Door
10 Install Thumb Turn
1. Insert thumb turn into preparation hole and engage slot in lock body.
2. Orient mounting plate so screw hole is vertical (aligned with
preparation holes).
3. Secure plate with phillips screw provided.
4. Test thumb turn for function by retracting and projecting the deadbolt
(7976 and 7977 functions only).
Phillips
screw
ar
Fig. 10
in
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
Thumb Turn
11 Inside Mounting Plate Installation
Mounting Plate
Fig. 11A
Fire shield
Inside of Door
2x Through bolts
open slot
Fig. 11B
Fig. 11C
Scan this Microsoft® Tag using
your mobile phone to see a
video of this installation step.
The Microsoft Tag mobile app
is required to scan the Tag.
Download the free mobile app at
http://gettag.mobi
1-800-810-WIRE • www.sargentlock.com • A8122B
11
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
2x Through bolts
8/05/12
Pr
el
im
1. Install washers onto both through bolts, Fig. 11A.
Insert the through bolts through the upper and lower
holes of the mounting plate.
2. Feed the DPS wire through the hole of the fire shield
and feed the lock wiring into the slot, Fig. 11B.
3. Place the fire shield against the door and place the mounting
plate over it so the through bolts align with the door holes.
IN100 Mortise Lock
12 Gasket Installation (Optional P/N 52-1332)
Gasket required for exterior doors (not required for fire rating). Figure 12.
1. Place the gasket on the on the reader posts and ensure the shape is
aligned with the edge of the reader.
Fig. 12
1. Orient the reader so the HID logo is at the bottom
and the lens is at the top.
2. Feed the ribbon cable through the door (from out
side to inside).
3. Install the reader to the outside of door by aligning
the mounting posts with the door preparation holes.
Hold the reader in position with hand.
4. While gently pressing upward on the outside reader,
tighten the (2) through bolts on the inside of the door to
secure the reader.
Pr
el
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
8/050/12
im
13 Outside Reader Installation
in
ar
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
Outside of Door
Inside of Door
HID Reader
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
12
1-800-810-WIRE • www.sargentlock.com • A8122B
Fig. 13A
Fig. 13B
IN100 Mortise Lock
14 Configuring RX Switch Handing
Inside of Door
1. Each lever handle has a sensor installed but only the inside lever is
utilized for RX sensing.
2. To properly configure the RX functionality, connect the terminals as
indicated below:
RH or RHRB door handing (blue to blue)
LH or LHRB door handing (yellow to blue)
3. Note: Factory default is blue to blue (right hand lock).
IMPORTANT: grasp each connector firmly before separating.
Do not pull wires apart.
DPS
Lock
body
wiring
ar
Wire harness
DPS
Lock
body
wiring
Pr
el
im
1. Connect the outside reader ribbon cable to the top of the
battery housing (See Fig.15B for detail).
2. Connect the DPS wire to the 3-wire header at the lower
left corner of the PCB.
3. Connect the lock body harness to the 5-wire header at
the lower right corner of the PCB.
IMPORTANT: Confirm the correct connector orientation
prior to assembly. Do not force connectors
Note: If the HID wire harness must be twisted to connect to
the battery housing the HID reader has been installed upside
down. Turn the HID reader right side up and reinstall, then
connect.
Fig. 14
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
15 Battery Housing Wiring
in
Scan this Microsoft® Tag using your mobile
phone to see a video of this installation
step. The Microsoft Tag mobile app is
required to scan the Tag. Download the free
mobile app at http://gettag.mobi
Wire harness
Fig. 15A
1-800-810-WIRE • www.sargentlock.com • A8122B
13
8/05/12
Fig. 15B
IN100 Mortise Lock
16 Battery Housing Installation
Inside of Door
1. Position the DPS and harness below the tabs of the
mounting plate.
2. Align the tabs of the battery housing with the tabs of the
mounting plate. Push down.
3. Lightly press the lock harness to assemble.
4. Snap battery compartment into position.
8/050/12
im
Fig. 16
Pr
el
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
in
ar
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
Inside of Door
17 Battery Installation
1. Place (6) “AA” alkaline batteries in the compartment, being
careful to align polarity properly.
2. After batteries are installed an audible “beep” will sound, the
lock motor will cycle. Refer to page 18, section “Lock Self
Test LED Indication”, for proper power up LED indications.
Scan this Microsoft® Tag using your mobile phone
to see a video of this installation step. The Microsoft
Tag mobile app is required to scan the Tag.
Download the free mobile app at http://gettag.mobi
14
1-800-810-WIRE • www.sargentlock.com • A8122B
Fig. 17
IN100 Mortise Lock
18 Inside Cover Installation
1. Assemble cover by hooking top edge on inside
mounting plate.
2. Carefully press bottom of cover toward door without
pinching any wires.
3. Secure the cover utilizing a 1/8” security Allen wrench.
Inside of Door
Inside
Cover
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
For battery replacement:
When replacing the (6) “AA” alkaline batteries in the
compartment, please note batteries must be replaced within 5
minutes to prevent the internal clock from becoming inaccurate.
1-800-810-WIRE • www.sargentlock.com • A8122B
15
8/05/12
Maintenance
Pr
el
Fig. 18
im
in
ar
1/8” Security
Allen Screw
IN100 Mortise Lock
Operational Check
For 7976- and 7978-function mortise locks with cylinders:
1. Insert key into cylinder and rotate.
There should be no friction against lock case, wire harness or
any other obstructions.
2. Check that the key retracts the latch:
the key should rotate freely.
3. Throw the deadbolt (if present): Check that the
key retracts both the deadbolt and the latch.
8/050/12
Pr
el
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
im
in
ar
5. Present a valid iCLASS or 125 kHz prox credential to unlock
outside lever and retract latch.
Note: The credential should approach the
inscription on the reader as indicated to ensure the
credential is read properly. Do not wave credential.
4. Try the inside lever:
Ensure it retracts latch and deadbolt (if provided).
16
1-800-810-WIRE • www.sargentlock.com • A8122B
IN100 Mortise Lock
Lock LED Indications
1 Lock Normal Operation LED indication
The lock has three LEDs that support an optical scheme with red, yellow and green.
The indication scheme is described by the figures below:
Card read (configurable)
One yellow flash (.25 seconds)
Access granted, EAC offline or online
One green flash (1 second)
Access denied, EAC online
One red flash (1 second)
Access denied, EAC offline
Three red flashes (.5 second each)
Lock mechanism is blocked when
closing
ar
Continuous red flashes blocked when closing
(.125 seconds every 1 second)
Time to replace the battery
im
Battery reached end of life, lock
disabled
in
Error in lock, maintenance required
Ten red flashes (.125 seconds each),
maintenance required; repeated if lock can’t
close
Continuous yellow flashes (.25 seconds every
5 seconds)
Fig. Lock Normal operation LED indication Continuous red flashes, (.25 seconds every 5
Pr
el
NOTE: Ensure the tamper switch activator does not fall out of the cover during assembly.
A tamper event message will be sent to the EAC panel if tamper is enabled. The “Error in
lock” indication is also shown instead of the POST flashes if the battery is not accepted as
new after a power-on-reset.
2 Lock Maintenance LED Indication
Some special LED indication schemes are used during lock maintenance actions:
Enter configuration
mode
Five yellow flashes (.125 seconds each)
Fig. Lock maintenance LED indication
1-800-810-WIRE • www.sargentlock.com • A8122B
17
8/05/12
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
seconds)
IN100 Mortise Lock
3 Lock Self Test LED Indication
After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated
using a series of red and green LED flashes as is described by the figure below:
One red, one green flash (1 second each)
Good POST
Bad POST
One red flash followed by 16 red or green
flashes (.5 seconds each)
The “Error in lock” indication is also
shown instead of the POST flashes
if the battery is not accepted as new
after a power-on-reset.
10 red flashes.
Fig. Lock POST LED indication
8/050/12
Meaning if Red
Main board firmware corrupt
Override list corrupt
Code in Event Log
0x0001
in
0x0002
Production data corrupt
0x0004
Security data corrupt
0x0008
Configuration data corrupt
0x0010
Battery power low
0x0020
RFID reader circuit error
0x0040
Voltage regulator error
0x0080
im
Pr
el
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Blink
ar
The first flash is always red. If the POST fails, the color of the 16 trailing flashes indicate the
status of each individual test as described by the following table:
10
Card detection circuit error
0x0100
11
Secure area communication error
0x0200
12
Secure area memory corrupt
0x0400
13
Secure area sensor or motor error
0x0800
14
Radio modem communication error
0x1000
15
Radio modem memory corrupt
0x2000
16
Radio modem configuration error
0x4000
17
Radio modem RF circuit error
0x8000
NOTE: If the battery is not accepted as new after a power on reset, no POST is performed.
Instead, the 10 quick red flashes used to indicate Error in lock is shown.
18
1-800-810-WIRE • www.sargentlock.com • A8122B
Pr
el
im
in
ar
Notes
The global leader in door opening solutions
y
ar
in
im
Pr
el
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A8122B - 8/12

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 21
XMP Toolkit                     : 3.1-701
Producer                        : ScanSoft PDF Create! 7
Creator Tool                    : Microsoft Word - 12-0305 - Exhibit Cover
Create Date                     : 2012:08:10 10:53:48-04:00
Modify Date                     : 2012:08:10 10:53:54-04:00
Title                           : Microsoft Word - 12-0305 - Exhibit Cover
Creator                         : courtney.merrick
Author                          : courtney.merrick
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYPROX5

Navigation menu