Aclara Technologies 11583 TRANSMITTER FOR METER READING User Manual MTU Instruction

Aclara Technologies LLC TRANSMITTER FOR METER READING MTU Instruction

USERS MANUAL

Download: Aclara Technologies 11583 TRANSMITTER FOR METER READING User Manual MTU Instruction
Mirror Download [FCC.gov]Aclara Technologies 11583 TRANSMITTER FOR METER READING User Manual MTU Instruction
Document ID758048
Application ID2YiIPwZ1J7LR2J/fEPoaOg==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize265.05kB (3313167 bits)
Date Submitted2007-02-12 00:00:00
Date Available2007-02-13 00:00:00
Creation Date2006-11-15 14:40:51
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2006-11-15 14:43:38
Document TitleMTU Instruction
Document CreatorAcrobat PDFMaker 7.0.7 for Word
Document Author: Hexagram, Inc.

MTU Instruction
for Actaris/Sprague/Schlumberger Gas Meters
Purpose & Scope
This instruction provides a procedure for installing a STAR direct-mount MTU on the
following Actaris/Sprague/Schlumberger residential gas meters: 175, 250 and 400 (Slantface).
Parts Required
Ref. #
2a
2b
2c
Item
Gasket
MTU, Direct Mount
Magnet Coupler
Coupler Shaft
Register Coupler
#10 x 3/8” combo head thread form screw, Type B, zinc
10-24 x 2” slotted fillister head machine screw, zinc
471-2031 - 11/15/2006
PRELIMINARY
Part Number
066-11583
506-11583
part of 506-7712BSP1
part of 506-7712BSP1
part of 506-7712BSP1
069-100012C4A
069-102464HA
Quantity
MTU Instruction
for Actaris/Sprague/Schlumberger Gas Meters
Tools Required
CAUTION!
Do not over tighten screws.
Excessive torque may
damage the MTU enclosure.
Use of power tools is not
recommended.
To mount the MTU to these meters, you
will need the following tools and
equipment:
• Safety glasses
• Phillips screwdriver
• Slotted screwdriver
Installation Procedure
Before installing the MTU, all anti-tamper,
safety, and security hardware must be
removed from the clear register cover.
Step 1 - Remove the existing clear
register cover by removing the three
screws that hold it. Set the cover aside
and discard the screws.
Step 2 - Remove the register by
removing the two screws that hold it. Set
the register aside and discard the screws.
Step 3 – Next, mount the register onto
the MTU (see illustration below) fastening
the register to the MTU with the #10 x
3/8” screws provided.
Step 4 – Check that the register is
properly engaged by rotating the coupler
on the back of the MTU and observing
the register dials.
Step 5 – Next, Insert the three 10-24 x 2”
machine screws through the holes on the
register cover and MTU as shown below.
Step 6– Turn the MTU over and place the
gasket on the back of the MTU so that it
aligns over the three mounting screws.
Start the two screws into the mounting
holes, and then slide the register beneath
the screws, making sure that the wiggler
on the register is aligned with the MTU
coupler. Tighten both screws to a torque
not to exceed 3-5 inch-pounds.
PRELIMINARY
MTU Instruction
for Actaris/Sprague/Schlumberger Gas Meters
Step 7 – Next, position the MTU on the
meter. Rotate the coupler into position to
ensure that it engages correctly with the
wiggler on the gas meter.
Step 8 – Now, firmly hand tighten the
mounting screws to 12 to 15 in-lb. The
gasket should be compressed slightly.
Be careful not to over tighten the screws.
Excessive torque may damage the MTU
enclosure. Because of this, power tools
are not recommended for this procedure.
Step 9 - Replace any anti-tamper, safety,
or security hardware onto the plastic
cover as required.
Step 10 – Once Installation is complete,
program the MTU using the STAR
Programmer Software and your MTU
Programmer.
PRELIMINARY
MTU Instruction
for Actaris/Sprague/Schlumberger Gas Meters
The FCC wants you to know…..
This equipment has been tested and complies with Part 15 and Part 90 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference. This equipment generates, uses
and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, try to correct the interference by one or more of the following measures:
• Reorient or relocate the equipment.
• Increase the separation distance between the affected equipment and receiver.
• Consult Hexagram, Inc. for help.
Any changes or modifications to this equipment not expressly approved by the Hexagram, Inc. could void the
authorization to operate the equipment.
FCC RF Exposure Guidelines
Hexagram’s low power RF devices and their antennas must be fixed-mounted on indoor or outdoor
permanent structure(s) providing a separation distance of at least 20 cm from all persons during normal
operation. This device is not designed (and it has no external connection) to operate in conjunction with any
other antennas or transmitters. No other operating instructions for satisfying RF exposure compliance are
needed. This unit has no user or installer serviceable parts, and requires no field adjustment or calibration.
Units are sealed at the factory, and disruption of this seal could void the authorization to operate the
equipment.
Hexagram, Inc.
23905 Mercantile Road
Cleveland, OH 44122

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Date 0020completed              : D:20061115
Description 0                   : for American Meter Company Residential Gas Meters (Direct Mount)
Company                         : Hexagram, Inc.
Comments                        : 175, 250 and 400 (Slant-face)
Source Modified                 : D:20061115194020
Category                        : Mounting/Installation
Creator Tool                    : Acrobat PDFMaker 7.0.7 for Word
Modify Date                     : 2006:11:15 14:43:38-05:00
Create Date                     : 2006:11:15 14:40:51-05:00
Metadata Date                   : 2006:11:15 14:43:38-05:00
Document ID                     : uuid:d5212bd4-cc10-4857-9fc1-67b5f9eead2f
Instance ID                     : uuid:ad8543da-aac8-4b58-9732-870b0fbfa7f9
Version ID                      : 36
Format                          : application/pdf
Title                           : MTU Instruction
Creator                         : Hexagram, Inc.
Description                     : for Actaris/Sprague/Schlumberger Gas Meters
Subject                         : 471-2031
Headline                        : for Actaris/Sprague/Schlumberger Gas Meters
Page Count                      : 4
Page Layout                     : OneColumn
Author                          : Hexagram, Inc.
Keywords                        : 471-2031
Date Completed                  : D:20061115
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LLB11583

Navigation menu