Ademco 7722TX User Manual installation instructions

Honeywell International Inc. installation instructions

installation instructions

Download: Ademco 7722TX User Manual installation instructions
Mirror Download [FCC.gov]Ademco 7722TX User Manual installation instructions
Document ID83540
Application IDpmhBW6aGbyZKidHpjoza6w==
Document Descriptioninstallation instructions
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.62kB (95270 bits)
Date Submitted2000-01-26 00:00:00
Date Available2000-03-08 00:00:00
Creation Date2000-01-03 15:40:34
Producing SoftwarePixel Translations (PIXPDF Ver.1.35)
Document Lastmod2000-01-03 15:47:07
Document Titleinstallation instructions
Document CreatorAcrobat 3.0 Capture Plug-in

wm2-2&m
Wireless Zone Sensor
Model 7722TX
(TRANE Part No. X13790126060)
INSTALLATIQN INSTRUCVONS
INTRODUCTION
This wireless zane sensor is designed for use in a
temperature control system, operating in conjunction with a
centrally located Spread Spectrum Receiver (Model 7712RX).
Zone sensors are installed in areas where temperature
control is to be maintained. Ideally, the receiver should be
equidistant from all its assigned zone sensors.
The zone sensor measures temperature and periodically
transmits that information via RF stgnals to its assigned
receiver. The sensor also transmits occupant set point
temperature. Other information that can be transmitted
includes special service requests, unique serial number of
sensor, and status of the batteries in the unit.
RF signals from wireless zone sensors are received by a
receiver, which will then send appropriate messages via
communication wires to specific .heating and air conditioning
equipment assigned to it. This information is also sent to a
central controller for system monitoring.
After mounting each wireless sensor, the Model 7712lT
Installation Tool can be used to assign each sensor to a
Figure 1. Typkal Wireless Sensor
‘tiooks’
i0
ii
necessary instructions for this are contained in the
instructions accompanying the 7712lT Installation Tool.
INSTALLATION
Location
Wireless sensors can be installed anywhere on common
walls and panitions. Operation will not be affected by metal
framing in walls or partitions; however, mounting to solid
metal walls or cabinets may reduce the operating distance
between the zone sensor and the receiver. Typical line-otsight transmission range indoors for sensors is approximately
1OOOfeet
Mounting (Fig. 2)
A mounting plate is provided with the sensor. If attached to
the back of the sensor, release it by depressing the ‘locking
tab’ at the bottom center of the mounting plate with the blade
of a screwdriver, and then sliding the plate downward.
Mount the plate on the selected wall or partition with the
VELCRO strips or screws provided. Hooks must point upward
(the plate also has the word ‘TOP’ molded into the top side).
Position the sensor onto the mounting plate so that the
mounting plate hooks enter the keyhole slots in the back of
the sensor, then slide downward to lock the sensor in place.
Battery Installation (Fig. 3)
The sensor uses two 3-volt Lithium batteries (supplied).
Remove the sensor cover by squeezing the cover at the top
and bottom and then pulling the cover away.
Install one battery in each compartment in the sensor. THE
SENSOR WILL N O T O P E R A T E WtTH ONLY ONE
BATTERY.
Note: Batteries will not seat properly in their compartments if
installed incorrectly with regard to polarity. Make sure each
battery is fully seated in the compartment and that proper
conted is being made at each end of the battery.
LCCANG TAB
Fkf~ure
2. Mounting Plate
WSHBlJl TON
SWrTC SIES
GREEN
LED’
a-w a4oER (For4 CONNECTION
OF INSTALlATlOh TOOL)
LOCKING TAB (P!AE.SS IN-WAR0
TO RELEASE SENSOR FROM PLATQ
Figure 3. Wireless tinsor, Cover Removed
Removing A Sensor From Its Mounting Plate
To remove a sensor from its mounting plate after installation,
press inward on the ‘locking tab’ at the bottom center (just to
the left of the &pin header), and slide the sensor up and off
the mounting plate. See Figure 3 for location of the locking
tab.
FUNCTIONAL ELECTRICAL TEST
This check should be performed after a zone sensor has
been mounted and the batleries installed. The cover must be
SPECIFICATIONS
Dlmenslonr:
Height: 4-l/16’
Wiih: 5’
Depth: l-5416’ (not incfuding mounting plate).
Range:
Nominal 1OOO feet fine-of-sight, indoors.
Two 3vdl&‘3A Lithium Batteries.
Otf.
If the sensor is equipped with a temperature control, set the
control dial with ‘70’ in the 9 o’clock position.
Press either one d the two pushbutton switches on .the upper
left side of the sensor. The green LED near the bottom of the
circuit board should flash each time the pushbutton is
pressed. If it does not, check that both batteries are good and
are property seated in the holders.
In normal use, the green LED will Hash each time the zone
sensor transmits a message, usually several minutes apart.
(103mmH x 127mmW x 33mmD)
Batledes:
SET-UP PROCEDURE
Rater to the sensor set-up procedures
Use only Trane No. X1377001 7010, Panasonic
CR123A, Duracell 1234 or Sanyo CR123A for
replacement.
Risk of fire, explosion and bur’ns. Do not
or inctnerate. Dispose of used batteries
In the instructions
8ccompanylng the Model 771211 installation Tool.
USER NOTE
CHANGES OR MOOIFICATIONS MAOE TO THIS EOUIPMENT WHICH ARE
NOT EXPRESSLY APPROVED BY THE AGENT FOR THE TRANE COMPANY
RESPONSIBLE FOR COMPLIANCE WITH FEDERAL REGULATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THIS EQUIPMENT.
THE TFIANE COMPANY,
Commercial Systems Group
3600 Pammel Creek Road,
Lacrosse, WI 54602
Copyright 0 1994

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Modify Date                     : 2000:01:03 15:47:07
Create Date                     : 2000:01:03 15:40:34
Producer                        : Pixel Translations (PIXPDF Ver.1.35)
Creator                         : Acrobat 3.0 Capture Plug-in
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CFS7722TX

Navigation menu