wm2-2&m Wireless Zone Sensor Model 7722TX (TRANE Part No. X13790126060) INSTALLATIQN INSTRUCVONS INTRODUCTION This wireless zane sensor is designed for use in a temperature control system, operating in conjunction with a centrally located Spread Spectrum Receiver (Model 7712RX). Zone sensors are installed in areas where temperature control is to be maintained. Ideally, the receiver should be equidistant from all its assigned zone sensors. The zone sensor measures temperature and periodically transmits that information via RF stgnals to its assigned receiver. The sensor also transmits occupant set point temperature. Other information that can be transmitted includes special service requests, unique serial number of sensor, and status of the batteries in the unit. RF signals from wireless zone sensors are received by a receiver, which will then send appropriate messages via communication wires to specific .heating and air conditioning equipment assigned to it. This information is also sent to a central controller for system monitoring. After mounting each wireless sensor, the Model 7712lT Installation Tool can be used to assign each sensor to a Figure 1. Typkal Wireless Sensor ‘tiooks’ i0 ii necessary instructions for this are contained in the instructions accompanying the 7712lT Installation Tool. INSTALLATION Location Wireless sensors can be installed anywhere on common walls and panitions. Operation will not be affected by metal framing in walls or partitions; however, mounting to solid metal walls or cabinets may reduce the operating distance between the zone sensor and the receiver. Typical line-otsight transmission range indoors for sensors is approximately 1OOOfeet Mounting (Fig. 2) A mounting plate is provided with the sensor. If attached to the back of the sensor, release it by depressing the ‘locking tab’ at the bottom center of the mounting plate with the blade of a screwdriver, and then sliding the plate downward. Mount the plate on the selected wall or partition with the VELCRO strips or screws provided. Hooks must point upward (the plate also has the word ‘TOP’ molded into the top side). Position the sensor onto the mounting plate so that the mounting plate hooks enter the keyhole slots in the back of the sensor, then slide downward to lock the sensor in place. Battery Installation (Fig. 3) The sensor uses two 3-volt Lithium batteries (supplied). Remove the sensor cover by squeezing the cover at the top and bottom and then pulling the cover away. Install one battery in each compartment in the sensor. THE SENSOR WILL N O T O P E R A T E WtTH ONLY ONE BATTERY. Note: Batteries will not seat properly in their compartments if installed incorrectly with regard to polarity. Make sure each battery is fully seated in the compartment and that proper conted is being made at each end of the battery. LCCANG TAB Fkf~ure 2. Mounting Plate WSHBlJl TON SWrTC SIES GREEN LED’ a-w a4oER (For4 CONNECTION OF INSTALlATlOh TOOL) LOCKING TAB (P!AE.SS IN-WAR0 TO RELEASE SENSOR FROM PLATQ Figure 3. Wireless tinsor, Cover Removed Removing A Sensor From Its Mounting Plate To remove a sensor from its mounting plate after installation, press inward on the ‘locking tab’ at the bottom center (just to the left of the &pin header), and slide the sensor up and off the mounting plate. See Figure 3 for location of the locking tab. FUNCTIONAL ELECTRICAL TEST This check should be performed after a zone sensor has been mounted and the batleries installed. The cover must be SPECIFICATIONS Dlmenslonr: Height: 4-l/16’ Wiih: 5’ Depth: l-5416’ (not incfuding mounting plate). Range: Nominal 1OOO feet fine-of-sight, indoors. Two 3vdl&‘3A Lithium Batteries. Otf. If the sensor is equipped with a temperature control, set the control dial with ‘70’ in the 9 o’clock position. Press either one d the two pushbutton switches on .the upper left side of the sensor. The green LED near the bottom of the circuit board should flash each time the pushbutton is pressed. If it does not, check that both batteries are good and are property seated in the holders. In normal use, the green LED will Hash each time the zone sensor transmits a message, usually several minutes apart. (103mmH x 127mmW x 33mmD) Batledes: SET-UP PROCEDURE Rater to the sensor set-up procedures Use only Trane No. X1377001 7010, Panasonic CR123A, Duracell 1234 or Sanyo CR123A for replacement. Risk of fire, explosion and bur’ns. Do not or inctnerate. Dispose of used batteries In the instructions 8ccompanylng the Model 771211 installation Tool. USER NOTE CHANGES OR MOOIFICATIONS MAOE TO THIS EOUIPMENT WHICH ARE NOT EXPRESSLY APPROVED BY THE AGENT FOR THE TRANE COMPANY RESPONSIBLE FOR COMPLIANCE WITH FEDERAL REGULATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THIS EQUIPMENT. THE TFIANE COMPANY, Commercial Systems Group 3600 Pammel Creek Road, Lacrosse, WI 54602 Copyright 0 1994
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Modify Date : 2000:01:03 15:47:07 Create Date : 2000:01:03 15:40:34 Producer : Pixel Translations (PIXPDF Ver.1.35) Creator : Acrobat 3.0 Capture Plug-in Page Count : 2EXIF Metadata provided by EXIF.tools