Ademco 8DL5898 Dual Tech Motion Detector User Manual

Honeywell International Inc. Dual Tech Motion Detector P800 01801A FCC

a href="https://usermanual.wiki/Ademco" itemprop="url"> Ademco >

User Manual

     5898 Wireless DUAL TEC® Motion Sensor  - Installation Instructions    PRELIMINARY DRAFT 5/18/09 - 1 - OPEN / OUVERTURE / APERTURALOCATION / EMPLACEMENT / LOCALIZACIÓN2.1 - 2.4 m(7 - 8 ft)ABWide Angle Lens (installed)Wide Angle Lens (installed)Wide Angle Lens (installed)Animal Immune Lens (included)Animal Immune Lens (included)Animal Immune Lens (included)21COMPONENTS AND SETTINGS / COMPONENTS AND SETTINGS / COMPONENTS AND SETTINGS CRange AdjustmentRéglage de la portée hyperAjuste del rango de detecciónECONNECT THE BATTERIES / CONNECT THE BATTERIES / CONNECT THE BATTERIES DMOUNT / INSTALLATION / MONTAJE Rear Tamper Breakaway Tabs - Best if mounted to a stud, solid wood, or with a robust wall anchor.<FR-CA>Rear Tamper Breakaway Tabs - Best if mounted to a stud, solid wood, or with a robust wall anchor.<SP-LA>Rear Tamper Breakaway Tabs - Best if mounted to a stud, solid wood, or with a robust wall anchor.ON2 3 41ON23 41PIR Sensitivity - LOW; Pulse Count 2; Up to 100 lb (45 kg) Animal Immunity<FR-CA> PIR Sensitivity - LOW; Pulse Count 2; Up to 100 lb (45 kg) Animal Immunity<SP-Amer> PIR Sensitivity - LOW; Pulse Count 2; Up to 100 lb (45 kg) Animal ImmunityPIR Sensitivity - HIGH; Pulse Count 1; Up to 50 lb (22.6 kg) Animal Immunity<FR-CA> PIR Sensitivity - HIGH; Pulse Count 1; Up to 50 lb (22.6 kg) Animal Immunity<SP-Amer> PIR Sensitivity - HIGH; Pulse Count 1; Up to 50 lb (22.6 kg) Animal Immunity60 Hz Fluorescent Light Filter60 Hz Fluorescent Light Filter60 Hz Fluorescent Light Filter50 Hz Fluorescent Light Filter50 Hz Fluorescent Light Filter50 Hz Fluorescent Light FilterAlarm when < 45o F (7o C) for > 5 minutesAlarm when < 45o F (7o C) for > 5 minutesAlarm when < 45o F (7o C) for > 5 minutesAlarm when > 95o F (35o C) for > 5 minutesAlarm when > 95o F (35o C) for > 5 minutesAlarm when > 95o F (35o C) for > 5 minutesMicrowave Walk Test ModeMicrowave Walk Test ModeMicrowave Walk Test ModeNormal Walk Test ModeNormal Walk Test ModeNormal Walk Test Mode FCC and IC statements are at the bottom of page 8
     5898 Wireless DUAL TEC® Motion Sensor  - Installation Instructions  English  PRELIMINARY DRAFT 5/18/09 - 2 - 1     BEFORE MOUNTING  Before mounting the transmitter permanently, conduct Go/No Go tests (see control panel manual) to verify adequate signal strength and reorient or relocate the sensor if necessary.   For Animal Immunity: •  Mount the center of the sensor at 7.5 ft (2.3 m) high. •  Set the sensor to the Lowest or Low sensitivity (see step 6a). •  Install Animal Immune lens (5-532-489-01 - see Lens Change Instructions on page X). •  Install the look-down mask (see X). •  Install the sensor where animals cannot come within 6 ft (1.8 m) of the sensor by climbing on furniture or other objects. •  Aim the sensor away from stairways, furniture or other objects that can be climbed on by pets. 2  ENROLLING THE SENSOR   After connecting the battery, the sensor LED will blink once per second for up to 60 seconds (power up), then Normal walk test mode begins.  You must “enroll” the sensor’s ID in the system in this walk test mode. Eliminate activity in front of the sensor.  When prompted for the sensor ID number, wave a hand in front of the sensor lens to trigger alarms and send sensor ID information to the panel. Refer to the control panel’s manual and the programming tool manual for information on registering wireless devices.  Program the sensor as an “RF” type unit (supervised RF).  Loop 1  Low Sensitivity (Pulse Count 2) /  Animal Immunity [50 lb. (23 kg) / 100 lb. (45 kg)] Loop 2  High Sensitivity (Pulse Count 1) / No Animal Immunity    Loop 3 Low Temperature Alarm Fault = < 45° F    (7° C) for > 5 minutes Restore = > 48° F    (9° C) for > 5 minutes High Temperature Alarm Fault = > 95° F   (35° C) for > 5 minutes Restore = < 92° F    (33° C) for > 5 minutes  Loop 4  Tamper  3  WALK TEST MODES Normal Walk Test mode:  The 10-minute Normal walk test mode is designed to optimize sensor enrollment.  Only alarm signals for the selected sensitivity/loop are sent to the panel (default is low sensitivity / loop 1).  Use the flashlight feature described below to toggle the sensitivity / loop setting.   As you walk through the detection pattern, the sensor LED will either light or blink rapidly to indicate each alarm detection:   - LED turns ON for 3 seconds = low sensitivity / loop 1.  - LED blinks rapidly for 3 seconds = high sensitivity / loop 2. Flashlight feature: (only available for 24 hours after power-up.) •  Stand within 4 feet (1.2 m) of the sensor with a flashlight. •  Blink or wave the flashlight beam across the front of the sensor 3 to 5 times.  (For best results, use a flashlight with a strong light beam and time the blinks/waves approximately once every ½ second.)  •  The sensor LED will flash for 3 seconds to indicate the sensitivity / loop setting has been changed. •  Each time you use the flashlight feature the sensor sensitivity / loop toggles and the walk test timer restarts the walk test for 10 minutes.  To restart a 10 minute Normal walk test mode after it expires, activate the tamper by opening and closing the sensor.  If necessary, adjust the microwave range, pulse count or sensitivity setting. (For LED activation meaning, refer to the LED Indicator table.) 4  MICROWAVE WALK TEST – 10 MINUTES 1. Set the Microwave Walk Test DIP switch to ON, or toggle it ON and OFF. 2. Set Range Adjustment potentiometer to 25% and replace the cover.   3. Walk through the detection area and observe the LED.  4. If necessary, adjust the potentiometer until desired detection range is obtained. (For LED activation meaning, refer to the LED Indicator table.) Power UpTrouble or Anti-Mask Fast Blinking Red (LED Enabled or Disabled)Condition Indicator LEDSlow Blinking Red (will finish within 60 seconds)Indicator LEDsNormal Walk TestRed ON for 3 seconds if AlarmYellow ON for 2 seconds if Microwave event detectedGreen ON for 2 seconds if PIR event detectedMicrowave Walk TestRed ON if Microwave is set too highGreen ON if Microwave is set correctlyOFF if Microwave is set too low TROUBLESHOOTING The sensor indicates a trouble condition by blinking the LED once every 5 seconds.  If a trouble condition (self test failure) occurs, the RF supervision is suppressed and the panel reports a trouble (“check zone”) after the condition exceeds the panel’s RF transmitter supervision time.  (Self Tests: Microwave Supervision, End-to-End PIR self-test and Temperature Compensation.) Solution:  Remove and replace the battery.  If the trouble does not clear, replace the sensor.     Replace the battery within 7 days after a “low battery” message appears in the system’s display.    SPECIFICATIONS Range:  50’ x 60’ (15 m x 18 m) [installed] 35’ x 40’ (11 m x 12 m) [included] Batteries:  Four 1.5V AA Lithium Batteries (Use only Energizer L91) Battery Caution: Risk of fire, explosion and burns.  Do not recharge, disassemble, heat above 100° C (212° F), or incinerate.  Dispose of used batteries promptly.  Keep away from children. Microwave Frequency:  24.125 GHz (K-band) RF Frequency:  345 MHz PIR White Light Immunity:  6,500 Lux typical Fluorescent Light Filter:  50 Hz or 60 Hz, switch selectable  Operating Temperature:  -20° to 55° C  (-4° to 131° F),  5% - 95% relative humidity (non-condensing) Self-Tests:  Microwave supervision; End-to-End PIR self-test; Temperature Compensation Temperature Compensation:  Advanced Dual Slope PIR Fields of View:  Wide Angle Lens (P/N 5-532-439-01) 44 long range zones    12 intermediate zones 6 lower zones    4 look-down zones Animal Immune Lens (P/N 5-532-489-01) 44 long range zones    36 intermediate zones 18 lower zones    4 look-down zones Dimensions:  4.93” x 2.93” x 1.68” (12.5cm x 7.5cm x 4.3cm) Weight:  149.0 g (5.26 oz); Packaged:  205.0 g (7.23 oz) Accessories:  Optional Lens Kits -    Long Range Curtain Lens Kit  15 m x 3 m / 50’ x 10’  (P/N DT7000-LRLK)   High Security Lens Kit  11 m x 12 m / 35’ x 40’   (P/N DT7000-HSLK)   Pet Alley Lens Kit  11 m x 12 m / 35’ x 40’  (P/N DT7000-PALK) Mounting Brackets –   SMB-10 Swivel Mount Bracket (P/N 0-000-110-01)   SMB-10C Swivel Mount Ceiling Bracket (P/N 0-000-111-01)  Approval Listings:   FCC Part 15, Class B verified IC RSS-210, Class B verified C-Tick,    cULus Listed   COMPLIANCE NOTES •  Sensor must be tested once per year. •  Sensor must have a clear line-of-sight to protected area.
Download:
Mirror Download [FCC.gov]
Document ID1118011
Application IDWjRxw+YrU+B/pV1Z9yfdtg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize258.15kB (3226853 bits)
Date Submitted2009-06-02 00:00:00
Date Available2009-06-10 00:00:00
Creation Date2009-05-20 09:45:45
Producing SoftwarePrimoPDF
Document Lastmod2009-05-21 14:50:26
Document TitleMicrosoft Word - P800-01801A_FCC.doc
Document CreatorPrimoPDF http://www.primopdf.com/
Document Author: E727032
FCC ID Filing: CFS8DL5898

Navigation menu