Ademco 8DL5898 Dual Tech Motion Detector User Manual P800 01801A FCC
Honeywell International Inc. Dual Tech Motion Detector P800 01801A FCC
Ademco >
User Manual
FCC andSensor IC statements are at the bottom of page 8 5898 Wireless DUAL TEC® Motion - Installation Instructions LOCATION / EMPLACEMENT / LOCALIZACIÓN 2.1 - 2.4 m (7 - 8 ft) OPEN / OUVERTURE / APERTURA Animal Immune Lens (included) Animal Immune Lens (included) Animal Immune Lens (included) Wide Angle Lens (installed) Wide Angle Lens (installed) Wide Angle Lens (installed) COMPONENTS AND SETTINGS / COMPONENTS AND SETTINGS / COMPONENTS AND SETTINGS PIR Sensitivity - LOW; Pulse Count 2; Up to 100 lb (45 kg) Animal ImmunityPIR Sensitivity - LOW; Pulse Count 2; Up to 100 lb (45 kg) Animal Immunity PIR Sensitivity - LOW; Pulse Count 2; Up to 100 lb (45 kg) Animal Immunity ON Alarm when > 95 F (35 C) for > 5 minutes Alarm when > 95 F (35 C) for > 5 minutes Alarm when > 95 F (35 C) for > 5 minutes 50 Hz Fluorescent Light Filter 50 Hz Fluorescent Light Filter 50 Hz Fluorescent Light Filter 60 Hz Fluorescent Light Filter 60 Hz Fluorescent Light Filter 60 Hz Fluorescent Light Filter ON Alarm when < 45 F (7 C) for > 5 minutes Alarm when < 45 F (7 C) for > 5 minutes Alarm when < 45 F (7 C) for > 5 minutes PIR Sensitivity - HIGH; Pulse Count 1; Up to 50 lb (22.6 kg) Animal Immunity PIR Sensitivity - HIGH; Pulse Count 1; Up to 50 lb (22.6 kg) Animal Immunity PIR Sensitivity - HIGH; Pulse Count 1; Up to 50 lb (22.6 kg) Animal Immunity Normal Walk Test Mode Normal Walk Test Mode Normal Walk Test Mode Microwave Walk Test Mode Microwave Walk Test Mode Microwave Walk Test Mode Range Adjustment Réglage de la portée hyper Ajuste del rango de detección CONNECT THE BATTERIES / CONNECT THE BATTERIES / CONNECT THE BATTERIES MOUNT / INSTALLATION / MONTAJE Rear Tamper Breakaway Tabs - Best if mounted to a stud, solid wood, or with a robust wall anchor. Rear Tamper Breakaway Tabs - Best if mounted to a stud, solid wood, or with a robust wall anchor. Rear Tamper Breakaway Tabs - Best if mounted to a stud, solid wood, or with a robust wall anchor. PRELIMINARY DRAFT 5/18/09 -1- 5898 Wireless DUAL TEC® Motion Sensor - Installation Instructions English 1 BEFORE MOUNTING Indicator LEDs Before mounting the transmitter permanently, conduct Go/No Go tests (see control panel manual) to verify adequate signal strength and reorient or relocate the sensor if necessary. For Animal Immunity: • Mount the center of the sensor at 7.5 ft (2.3 m) high. • Set the sensor to the Lowest or Low sensitivity (see step 6a). • Install Animal Immune lens (5-532-489-01 - see Lens Change Instructions on page X). • Install the look-down mask (see X). • Install the sensor where animals cannot come within 6 ft (1.8 m) of the sensor by climbing on furniture or other objects. • Aim the sensor away from stairways, furniture or other objects that can be climbed on by pets. Condition Indicator LED Power Up Slow Blinking Red (will finish within 60 seconds) Red ON for 3 seconds if Alarm Yellow ON for 2 seconds if Microwave event detected Green ON for 2 seconds if PIR event detected Normal Walk Test Microwave Walk Test Trouble or Anti-Mask TROUBLESHOOTING 2 ENROLLING THE SENSOR The sensor indicates a trouble condition by blinking the LED once every 5 seconds. If a trouble condition (self test failure) occurs, the RF supervision is suppressed and the panel reports a trouble (“check zone”) after the condition exceeds the panel’s RF transmitter supervision time. (Self Tests: Microwave Supervision, End-to-End PIR self-test and Temperature Compensation.) Solution: Remove and replace the battery. If the trouble does not clear, replace the sensor. Replace the battery within 7 days after a “low battery” message appears in the system’s display. After connecting the battery, the sensor LED will blink once per second for up to 60 seconds (power up), then Normal walk test mode begins. You must “enroll” the sensor’s ID in the system in this walk test mode. Eliminate activity in front of the sensor. When prompted for the sensor ID number, wave a hand in front of the sensor lens to trigger alarms and send sensor ID information to the panel. Refer to the control panel’s manual and the programming tool manual for information on registering wireless devices. Program the sensor as an “RF” type unit (supervised RF). Loop 1 Low Sensitivity (Pulse Count 2) / Animal Immunity [50 lb. (23 kg) / 100 lb. (45 kg)] Loop 2 High Sensitivity (Pulse Count 1) / No Animal Immunity Loop 3 Low Temperature Alarm Fault = < 45° F (7° C) for > 5 minutes Restore = > 48° F (9° C) for > 5 minutes Loop 4 Red ON if Microwave is set too high Green ON if Microwave is set correctly OFF if Microwave is set too low Fast Blinking Red (LED Enabled or Disabled) SPECIFICATIONS Range: 50’ x 60’ (15 m x 18 m) [installed] 35’ x 40’ (11 m x 12 m) [included] High Temperature Alarm Fault = > 95° F (35° C) for > 5 minutes Restore = < 92° F (33° C) for > 5 minutes Batteries: Four 1.5V AA Lithium Batteries (Use only Energizer L91) Battery Caution: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 100° C (212° F), or incinerate. Dispose of used batteries promptly. Keep away from children. Microwave Frequency: 24.125 GHz (K-band) RF Frequency: 345 MHz Tamper PIR White Light Immunity: 6,500 Lux typical Fluorescent Light Filter: 50 Hz or 60 Hz, switch selectable WALK TEST MODES Operating Temperature: -20° to 55° C (-4° to 131° F), 5% - 95% relative humidity (non-condensing) Normal Walk Test mode: The 10-minute Normal walk test mode is designed to optimize sensor enrollment. Only alarm signals for the selected sensitivity/loop are sent to the panel (default is low sensitivity / loop 1). Use the flashlight feature described below to toggle the sensitivity / loop setting. As you walk through the detection pattern, the sensor LED will either light or blink rapidly to indicate each alarm detection: - LED turns ON for 3 seconds = low sensitivity / loop 1. - LED blinks rapidly for 3 seconds = high sensitivity / loop 2. Self-Tests: Microwave supervision; End-to-End PIR self-test; Temperature Compensation Temperature Compensation: Advanced Dual Slope PIR Fields of View: Wide Angle Lens (P/N 5-532-439-01) 44 long range zones 12 intermediate zones 6 lower zones 4 look-down zones Animal Immune Lens (P/N 5-532-489-01) 44 long range zones 36 intermediate zones 18 lower zones 4 look-down zones Flashlight feature: (only available for 24 hours after power-up.) • Stand within 4 feet (1.2 m) of the sensor with a flashlight. • Blink or wave the flashlight beam across the front of the sensor 3 to 5 times. (For best results, use a flashlight with a strong light beam and time the blinks/waves approximately once every ½ second.) • The sensor LED will flash for 3 seconds to indicate the sensitivity / loop setting has been changed. • Each time you use the flashlight feature the sensor sensitivity / loop toggles and the walk test timer restarts the walk test for 10 minutes. Dimensions: 4.93” x 2.93” x 1.68” (12.5cm x 7.5cm x 4.3cm) Weight: 149.0 g (5.26 oz); Packaged: 205.0 g (7.23 oz) Accessories: Optional Lens Kits Long Range Curtain Lens Kit 15 m x 3 m / 50’ x 10’ (P/N DT7000-LRLK) High Security Lens Kit 11 m x 12 m / 35’ x 40’ (P/N DT7000-HSLK) Pet Alley Lens Kit 11 m x 12 m / 35’ x 40’ (P/N DT7000-PALK) To restart a 10 minute Normal walk test mode after it expires, activate the tamper by opening and closing the sensor. Mounting Brackets – SMB-10 Swivel Mount Bracket (P/N 0-000-110-01) SMB-10C Swivel Mount Ceiling Bracket (P/N 0-000-111-01) Approval Listings: FCC Part 15, Class B verified IC RSS-210, Class B verified C-Tick, cULus Listed If necessary, adjust the microwave range, pulse count or sensitivity setting. (For LED activation meaning, refer to the LED Indicator table.) MICROWAVE WALK TEST – 10 MINUTES 1. Set the Microwave Walk Test DIP switch to ON, or toggle it ON and OFF. 2. Set Range Adjustment potentiometer to 25% and replace the cover. 3. Walk through the detection area and observe the LED. 4. If necessary, adjust the potentiometer until desired detection range is obtained. (For LED activation meaning, refer to the LED Indicator table.) PRELIMINARY DRAFT 5/18/09 COMPLIANCE NOTES • Sensor must be tested once per year. • Sensor must have a clear line-of-sight to protected area. -2- 5898 Wireless DUAL TEC® Motion Sensor - Installation Instructions 1 SELECT MOUNTING LOCATION (See Indicator LEDs Additional guidelines for animal immunity: • Mount the center of the sensor at 2.3 m (7.5 feet) high. • Set the sensor to the Lowest or Low sensitivity (see step 6a). • Install Animal Immune lens (5-532-489-01 - see Lens Change Instructions on page 3). • Install the look-down mask (see Step 6a). • Install the sensor where animals cannot come within 1.8 m (6 ft) of the sensor by climbing on furniture or other objects. • Aim the sensor away from stairways, furniture or other objects that can be climbed on by pets. • TEST the installation site to determine the exact level of attainable animal immunity. 2 REMOVE THE FRONT HOUSING (SEE Condition Indicator LED Power Up Slow Blinking Red (will finish within 60 seconds) Red ON for 3 seconds if Alarm Yellow ON for 2 seconds if Microwave event detected Green ON for 2 seconds if PIR event detected Normal Walk Test Microwave Walk Test Trouble or Anti-Mask B) Red ON if Microwave is set too high Green ON if Microwave is set correctly OFF if Microwave is set too low Fast Blinking Red (LED Enabled or Disabled) TROUBLESHOOTING 3 SELECT THE RANGE, SENSITIVITY AND PROTOCOL (SEE 4 CONNECT THE BATTERIES (SEE FR-Canadian RED LED flashing rapidly during normal operation indicates a trouble condition. A microwave, PIR, or temperature compensation fault is present, or a communication error has occured. Supervision errors and low battery conditions are indicated at the panel. C) D) Solution: Momentarily power down the sensor by removing and replacing all the batteries. If the trouble does not clear, replace the sensor. 5 REGISTER THE SENSOR TO THE PANEL Refer to the control panel’s manual and the programming tool manual for information on registering wireless devices. SPECIFICATIONS Once you enter the sensor serial number into the panel programming, select the desired loop for that zone. Range: 50’ x 60’ (15 m x 18 m) [installed] 35’ x 40’ (11 m x 12 m) [included] Batteries: Four 1.5V AA Lithium Batteries (Use only Energizer L91) Serial # / LOOP Serial #1 / Loop 1 High Sensitivity No Animal Immunity Serial #1 / Loop2 Low Sensitivity / Animal Immunity [23 kg (50 lb.) / 45 kg (100 lb.)] Serial #2 / Loop 1 Low Temperature Trip When temperature drops below 7° C ± 2° C (45° F ± 4° F) for 5 minutes Serial #2 / Loop 2 High Temperature Trip When temperature rises above 35° C ± 2° C (95° F ± 4° F) for 5 minutes 6 MOUNT THE SENSOR (SEE Battery Caution: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 100° C (212° F), or incinerate. Dispose of used batteries promptly. Keep away from children. Pulse Count 1 Microwave Frequency: 24.125 GHz (K-band) RF Frequency: 345 MHz Pulse Count 2 PIR White Light Immunity: 6,500 Lux typical Fluorescent Light Filter: 50 Hz or 60 Hz, switch selectable Low Temp Restoral When temperature rises + 2° C (+ 3° F) above low temperature trip point Low Temp Restoral When temperature crops - 2° C (- 3° F) below high temperature trip point Operating Temperature: -20° to 55° C (-4° to 131° F), 5% - 95% relative humidity (non-condensing) Self-Tests: Microwave supervision; End-to-End PIR self-test; Temperature Compensation Temperature Compensation: Advanced Dual Slope PIR Fields of View: Wide Angle Lens (P/N 5-532-439-01) 44 long range zones 12 intermediate zones 6 lower zones 4 look-down zones Animal Immune Lens (P/N 5-532-489-01) 44 long range zones 36 intermediate zones 18 lower zones 4 look-down zones Dimensions: 4.93” x 2.93” x 1.68” (12.5cm x 7.5cm x 4.3cm) 7 NORMAL WALK TEST– 10 MINUTES Weight: 149.0 g (5.26 oz); Packaged: 205.0 g (7.23 oz) Normal walk test mode activates every time the front cover is closed and remains active for 10 minutes. For an additional 10 minutes of walk test time, remove and replace the front cover. In walk test mode, the LED is always enabled. Walk through the detection area and observe the LED. If necessary, adjust the microwave range, pulse count or sensitivity setting. (For LED activation meaning, refer to the LED Indicator table.) Accessories: Optional Lens Kits Long Range Curtain Lens Kit 15 m x 3 m / 50’ x 10’ (P/N DT7000-LRLK) High Security Lens Kit 11 m x 12 m / 35’ x 40’ (P/N DT7000-HSLK) Pet Alley Lens Kit 11 m x 12 m / 35’ x 40’ (P/N DT7000-PALK) Mounting Brackets – SMB-10 Swivel Mount Bracket (P/N 0-000-110-01) SMB-10C Swivel Mount Ceiling Bracket (P/N 0-000-111-01) Approval Listings: FCC IC CE, C-Tick, cULus Listed 8 MICROWAVE WALK TEST – 10 MINUTES 1. Set the Microwave Walk Test DIP switch to ON, or toggle it ON and OFF. 2. Set Range Adjustment potentiometer to 25% and replace the cover. 3. Walk through the detection area and observe the LED. 4. If necessary, adjust the potentiometer until desired detection range is obtained. (For LED activation meaning, refer to the LED Indicator table.) PRELIMINARY DRAFT 5/18/09 COMPLIANCE NOTES • Sensor must be tested once per year. • Sensor must have a clear line-of-sight to protected area. -3- 5898 Wireless DUAL TEC® Motion Sensor - Installation Instructions 1 SELECT MOUNTING LOCATION (See Indicator LEDs Additional guidelines for animal immunity: • Mount the center of the sensor at 2.3 m (7.5 feet) high. • Set the sensor to the Lowest or Low sensitivity (see step 6a). • Install Animal Immune lens (5-532-489-01 - see Lens Change Instructions on page 3). • Install the look-down mask (see Step 6a). • Install the sensor where animals cannot come within 1.8 m (6 ft) of the sensor by climbing on furniture or other objects. • Aim the sensor away from stairways, furniture or other objects that can be climbed on by pets. • TEST the installation site to determine the exact level of attainable animal immunity. 2 REMOVE THE FRONT HOUSING (SEE Condition Indicator LED Power Up Slow Blinking Red (will finish within 60 seconds) Red ON for 3 seconds if Alarm Yellow ON for 2 seconds if Microwave event detected Green ON for 2 seconds if PIR event detected Normal Walk Test Microwave Walk Test Trouble or Anti-Mask B) Red ON if Microwave is set too high Green ON if Microwave is set correctly OFF if Microwave is set too low Fast Blinking Red (LED Enabled or Disabled) TROUBLESHOOTING 3 SELECT THE RANGE, SENSITIVITY AND PROTOCOL (SEE 4 CONNECT THE BATTERIES (SEE SP- Americas RED LED flashing rapidly during normal operation indicates a trouble condition. A microwave, PIR, or temperature compensation fault is present, or a communication error has occured. Supervision errors and low battery conditions are indicated at the panel. C) D) Solution: Momentarily power down the sensor by removing and replacing all the batteries. If the trouble does not clear, replace the sensor. 5 REGISTER THE SENSOR TO THE PANEL Refer to the control panel’s manual and the programming tool manual for information on registering wireless devices. SPECIFICATIONS Once you enter the sensor serial number into the panel programming, select the desired loop for that zone. Range: 50’ x 60’ (15 m x 18 m) [installed] 35’ x 40’ (11 m x 12 m) [included] Batteries: Four 1.5V AA Lithium Batteries (Use only Energizer L91) Serial # / LOOP Serial #1 / Loop 1 High Sensitivity No Animal Immunity Serial #1 / Loop2 Low Sensitivity / Animal Immunity [23 kg (50 lb.) / 45 kg (100 lb.)] Serial #2 / Loop 1 Low Temperature Trip When temperature drops below 7° C ± 2° C (45° F ± 4° F) for 5 minutes Serial #2 / Loop 2 High Temperature Trip When temperature rises above 35° C ± 2° C (95° F ± 4° F) for 5 minutes 6 MOUNT THE SENSOR (SEE Battery Caution: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 100° C (212° F), or incinerate. Dispose of used batteries promptly. Keep away from children. Pulse Count 1 Microwave Frequency: 24.125 GHz (K-band) RF Frequency: 345 MHz Pulse Count 2 PIR White Light Immunity: 6,500 Lux typical Fluorescent Light Filter: 50 Hz or 60 Hz, switch selectable Low Temp Restoral When temperature rises + 2° C (+ 3° F) above low temperature trip point Low Temp Restoral When temperature crops - 2° C (- 3° F) below high temperature trip point Operating Temperature: -20° to 55° C (-4° to 131° F), 5% - 95% relative humidity (non-condensing) Self-Tests: Microwave supervision; End-to-End PIR self-test; Temperature Compensation Temperature Compensation: Advanced Dual Slope PIR Fields of View: Wide Angle Lens (P/N 5-532-439-01) 44 long range zones 12 intermediate zones 6 lower zones 4 look-down zones Animal Immune Lens (P/N 5-532-489-01) 44 long range zones 36 intermediate zones 18 lower zones 4 look-down zones Dimensions: 4.93” x 2.93” x 1.68” (12.5cm x 7.5cm x 4.3cm) 7 NORMAL WALK TEST– 10 MINUTES Weight: 149.0 g (5.26 oz); Packaged: 205.0 g (7.23 oz) Normal walk test mode activates every time the front cover is closed and remains active for 10 minutes. For an additional 10 minutes of walk test time, remove and replace the front cover. In walk test mode, the LED is always enabled. Walk through the detection area and observe the LED. If necessary, adjust the microwave range, pulse count or sensitivity setting. (For LED activation meaning, refer to the LED Indicator table.) Accessories: Optional Lens Kits Long Range Curtain Lens Kit 15 m x 3 m / 50’ x 10’ (P/N DT7000-LRLK) High Security Lens Kit 11 m x 12 m / 35’ x 40’ (P/N DT7000-HSLK) Pet Alley Lens Kit 11 m x 12 m / 35’ x 40’ (P/N DT7000-PALK) Mounting Brackets – SMB-10 Swivel Mount Bracket (P/N 0-000-110-01) SMB-10C Swivel Mount Ceiling Bracket (P/N 0-000-111-01) Approval Listings: FCC IC CE, C-Tick, cULus Listed 8 MICROWAVE WALK TEST – 10 MINUTES 1. Set the Microwave Walk Test DIP switch to ON, or toggle it ON and OFF. 2. Set Range Adjustment potentiometer to 25% and replace the cover. 3. Walk through the detection area and observe the LED. 4. If necessary, adjust the potentiometer until desired detection range is obtained. (For LED activation meaning, refer to the LED Indicator table.) PRELIMINARY DRAFT 5/18/09 COMPLIANCE NOTES • Sensor must be tested once per year. • Sensor must have a clear line-of-sight to protected area. -4- 5898 Wireless DUAL TEC® Motion Sensor - Installation Instructions DETECTION PATTERNS / COUVERTURE DE DETECTION / PATRON DE DETECCIÓN 50’ / 15m Wide Angle Lens / Wide Angle Lens / Wide Angle Lens / (P/N 5-532-439-01 – Installed) Top View / VUE DE DESSUS / VISTA DESDE ARRIBA Side View / VUE DE COTE / VISTA LATERAL LENS MASKING / LENS MASKING / LENS MASKING / 5-532-439-01 50FT TOP 35’ / 11m Animal Immune Lens / Animal Immune Lens / Animal Immune Lens (P/N 5-532-489-01 – Included) Side View / VUE DE COTE / VISTA LATERAL Top View / VUE DE DESSUS / VISTA DESDE ARRIBA LENS MASKING / LENS MASKING / LENS MASKING / PRELIMINARY DRAFT 5/18/09 -5- 25 / 35FT 5-532-489-01 TOP 5898 Wireless DUAL TEC® Motion Sensor - Installation Instructions LENS CHANGE INSTRUCTIONS / LENS CHANGE INSTRUCTIONS / LENS CHANGE INSTRUCTIONS / LENS CHANGE INSTRUCTIONS / LENS CHANGE INSTRUCTIONS PRELIMINARY DRAFT 5/18/09 -6- 5898 Wireless DUAL TEC® Motion Sensor - Installation Instructions PRELIMINARY DRAFT 5/18/09 -7- 5898 Wireless DUAL TEC® Motion Sensor - Installation Instructions FCC NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: − Reorient or relocate the receiving antenna. − Increase the separation between the equipment and receiver. − Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. − Consult the dealer or an experienced radio/television technician for help. The user is cautioned that changes or modifications not expressly approved by Honeywell could void the user’s authority to operate this equipment. IC NOTICE: This Class B digital device complies with the Canadian RSS-210. Cet appareil numérique de la Classe B est conforme à la norme CNR-210 du Canada. This Class B digital device complies with RSS-210 of the IC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil numérique de la Classe B est conforme à la norme CNR-210 des règles d’IC. L’utilisation de ce dispositif est autorisée seulement aux deux conditions suivantes ; (1) il ne doit pas produire de brouillage, et (2) l’utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. 2009 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Made in China. For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorised Honeywell representative for product warranty information. Contacter un revendeur Honeywell autorisé pour obtenir des informations sur la garantie de ce produit. Por favor contacte con su distribuidor Honeywell Security para información sobre la garantía del producto. P/N P800-01801 Rev A PRELIMINARY DRAFT 5/18/09 -8-
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 8 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:0e4f4028-6b33-43f3-9ab8-c0284706c995 Producer : PrimoPDF Modify Date : 2009:05:21 14:50:26-04:00 Create Date : 2009:05:20 09:45:45-07:00 Creator Tool : PrimoPDF http://www.primopdf.com/ Metadata Date : 2009:05:21 14:50:26-04:00 Document ID : uuid:8514590c-254c-4607-a432-31cc7a68264d Format : application/pdf Title : Microsoft Word - P800-01801A_FCC.doc Creator : E727032 Author : E727032EXIF Metadata provided by EXIF.tools