Ademco 8DL6160RF Wireless keypad User Manual K0903
Honeywell International Inc. Wireless keypad K0903
Ademco >
II with FCC PT 15 Statements
Preliminary - 6 September 2002 K0903ax 9/6/02 5).(<3$'75$16&(,9(5 INSTALLATION GUIDE GENERAL INFORMATION Additional Features The 6160RF keypad/transceiver is a is a combination unit that contains the following: • A 6160 Alphanumeric Addressable Keypad • A 5881M RF Receiver • A 5800TM Transmitter Module The 6160RF Keypad/Transceiver may be used on any control panel that supports the 6160 Keypad (e.g., VISTA10SE, VISTA-15, VISTA-20SE, VISTA-40, VISTA-50P). • Provides tamper protection that causes the system to annunciate a trouble condition if the cover is removed. (If supported by the control panel). The tamper switch has not been evaluated for UL installation. • Capable of sending status signals (Armed, Ready, etc.) to bi-directional units such as 5804BD, 5804BDV and 5827BD. FEATURES Use the following guidelines when planning an installation: • If using bi-directional devices, be sure to enable the transmitter module in the 6160RF. • If transmitters are programmed into the control panel, be sure to enable the receiver. (Make sure you do not exceed the number of receivers supported by the control panel.) • You must set the House ID only if you are using RF keypads and/or bi-directional devices; AND the House ID Source is the 6160RF (Local). Wireless Features • Supports wireless key transmitters (5804, 5804BD). • Supports wireless keys with Signal Sentry (highsecurity) (5804E). • Provides a nominal range of 200' for the RF transmitters (some transmitters have a shorter range). • Supports RF jam detection when the receiver is enabled. UL The following transmitters are not intended for use in UL installations: 5804, 5804BD, 5804BDV, 5804E and 5827BD. Note: If the House ID source is the panel, enter *99 into keypad. Programming Features • Provides default settings for the functions of the wireless keys. • Provides a method to enroll up to eight (8) encrypted (high security) devices. Control Panel VISTA-10SE, VISTA-15, VIA-30PSE VISTA-20SE VISTA-40, VISTA-50P APPLICATION GUIDELINES FOR THE 6160RF RF keypads and/or Bi-directional devices on more than 1 partition? NO NO YES* NO** YES 6160RF Application Guide The guide, provided below, outlines how to program the wireless keys, RF receiver, and the House ID in the 6160RF for your particular installation. Program RF Receiver Enable House ID Source*** As System Enable Disable Enable Disable System Local System Local Two 6160RFs are needed for this application: one connected to partition 1’s keypad terminals, and one connected to partition 2’s. ** If using an RF keypad on only one partition, the 6160RF’s partition assignment must match the partition set in field 1*48. *** If set for Local on a partition control, the 6160RF’s partition assignment must match the one programmed in the BD device. Preliminary - 6 September 2002 b. If desired, wires may be strain-relieved to the wire tie point on the inside of the case back with a tie wrap (not supplied). INSTALLING THE 6160RF Locate the 6160RF in an area and at a height where it is convenient for user operation. The 6160RF must be at least 10 ft from the control panel to ensure proper operation of the RF receiver. 3. Mount the case back to a wall or to an electrical box using the 25mm-long self-tapping screws supplied (mollies for drywall are not supplied). Mounting And Wiring Note: If you wish to tamper-protect the keypad for removal from the wall, use an additional mounting screw in the tamper hole in the case back (see Figure 2 for location). The 6160RF has terminal blocks for connection to power and data wires, and relay contact wires. Removing the keypad’s case back accesses these terminal blocks. 4. Connect the power and data wires from the control panel to the terminals on the 6160RF as indicated Figure 3 and Table 1. The 6160RF can be surface mounted directly to walls, or to a single- or double-gang U.S./Italian style electrical box. Follow these steps to mount and wire the keypad: WIRING TERMINALS (TO CONTROL PANEL) 1. Detach the case back by pushing up into one of the two slots at the bottom of the keypad with the blade of a small screwdriver (this will push in the release snap), then pull that side of the case back away. Repeat for the other side. Refer to Figure 1 for location of the case back release snaps. Y + TAMPER SWITCH ARMED READY NOTE: TO REMOVE REAR COVER PUSH IN THE TWO MOUNTING SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD AND LIFT COVER UP. 6164RF-003-V0 MOUNTING RELEASE SNAPS 6160RF-002-V0 Figure 3 - 6160RF Wiring Details Table 1 - Wiring Table Keypad ▲G Figure 1. Removing the Case Back 2. Pass the wiring from the control panel through the opening in the case back. (see the control panel’s instructions for proper run lengths.) Control Panel Data In -Aux Pwr (GND) +Aux Pwr Data Out Wire Color Green Black Red Yellow 5. Re-attach the keypad to the mounted case back. Attach the top of the keypad first, and then press the bottom section down until it snaps into place securely. a. If surface wiring is being used, wiring may be routed through the top or the bottom left-side breakout in the case back. See Figure 2. The breakouts must be punched out using a screwdriver before mounting the case back. 6. Peel off protective film on the LED panel and install the keypad labels as required. 6160RF PROGRAMMING Entering Program Mode Press the [1] and [3] keys simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after removing the case back. The current keypad address CON ADDRESS = XX will be displayed. Press the [✳] key. Programming Operations Once you have entered the Program mode, you may advance between prompts by pressing the [✳] key. This will also store displayed information. Programming the 6160RF Note: Refer to the control panel’s installation instructions for the acceptable keypad and receiver addresses. • If you are using a wireless key in High-Security mode (e.g.;5804E) in the control panel, it will occupy one of the devices in the 6160RF. • When operating the system in High-Security mode, only encrypted wireless keys will function. STEP 1. 2. 3. 4. DESCRIPTION Enter the program mode by pressing the [1] and [3] keys simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after removing the case back. (Keypad Address) Enter the two digit keypad address. Press the [✳] key to continue. (Receiver Enable) Enter [1] to enable, or [0] to disable Receiver. Enable the receiver if RF transmitters or wireless keypads are programmed into the control. Press the [✳] key to continue. If receiver is enabled, enter the two digit receiver address. (01-30) Press the [✳] key to continue. (Transmitter Enable) Enter [1] to enable, or [0] to disable. Enter [1] if bi-directional devices are being used. Note: If the House ID source is the System, and more than one 6160RF is used, make sure only one has the Transmitter Module enabled. 5. Press the [✳] key to continue. (House ID) Enter 99 (System) to use the House ID programmed into the control panel Enter 01-31 (Local) to use the House ID programmed into the 6160RF. DISPLAY CHOICES '32%((6)77= << 01-31 6)')-:)6 32?= 3**A 1= ON 0 = OFF 6)'%((6)77= << 01-30 86%271-88)6 32?= 3**A 1= ON 0 = OFF ,397)-(= << 01-31 = Local 99 = System ,-+,7)'96-8= 3**?= 32A ()0)8)():-')7# 1= Enable 0 = Disable Notes: (1) If the House ID Source is the System, RF Keypads and bi-directional units MUST match the House ID programmed into the panel. (2) If the House ID Source is Local, the RF Keypads and bi-directional units MUST match the House ID programmed into the 6160RF. 6. Press the [✳] key to continue. (Enable High Security mode) Enter [1] to select High Security Mode Note: If this mode is enabled, the 6160RF will only recognize encrypted devices. 7. Press the [✳] key to continue. (Delete High Security Devices) Press the [✳] key to skip this prompt and exit Program Mode. Note: If you need to delete encrypted devices refer to the Deactivating High Security Devices section. 1= YES 0 = NO ACTIVATING HIGH SECURITY DEVICES This following procedure should be followed if using High-Security (encrypted) devices. STEP 1. 2. 3. 4. DESCRIPTION Put the control panel in Go/ No Go Test mode. (See the Installation Guide for the panel being installed.) Follow the instruction provided with the wireless device to for installing the High-security (encrypted) device. The 6160RF will momentarily display the serial number of the device. Disable the Go/ No Go Test mode and follow the normal procedure for programming the device into the control panel (refer to the Installation Instructions for the device that you are programming). DEACTIVATING HIGH SECURITY DEVICES This mode gives you the ability to disable all individual wireless keys that have been directly programmed into the 6160RF. This is particularly useful if a user loses a wireless key. STEP 1. 2. 3. High-Security (encrypted) devices must also be deleted from the panel. Once High-Security (encrypted) devices have been deleted, the devices will no longer function. DESCRIPTION Enter the keypad's local program mode within 60 seconds of power-up by pressing and holding down the [1] and [3] keys at the same time for 3 seconds. The current keypad address will be displayed with the cursor under the "tens" digit. Press the [✱] key to continue. (Delete High Security Devices) Press the [1] key to remove all highsecurity (encrypted) devices. Press the [✱] key to continue. If YES was selected in Step 2 the unit will display a confirm request to delete the stored high security device. Press the [1] key to accept, followed by the [✳] key to exit the programming mode. DISPLAY CHOICES '32%((6)77= << 01-31 ()0)8)():-')7# 23?==)7A %6)=39796)# 23?==)7A 1= YES 0 = NO 1= YES 0 = NO TROUBLESHOOTING The error messages listed in the following table cause the 6160RF to produce a single ding tone. The table describes the error messages and the corrective actions. Display Probable Cause Lb Low battery in the wireless key Open Ckt Incompat. Con. Check 09 Open circuit Incompatible connection Corrective Action 1. Replace the battery if the wireless key has a replaceable battery. 2. Replace the transmitter if the wireless key does not have a replaceable battery. Verify that the Data Out (DO) wire is connected properly. Verify that the control panel is not a First Alert-type control panel. 1. 6160RF Receiver is not communicating. 2. Another device on the keypad terminals is not communicating to the control panel. 1. Verify that the Data In (DI) wire is connected properly. 2. Verify the wiring connections between the control and all other devices. SPECIFICATIONS Physical: 5-3/8” H x 7-3/8” W x 1-1/4” D (137mm x 187mm x 32mm) Wiring: Refer to Table 1 Range: 200 ft (60.9 m) nominal Frequency: 345 MHz Current: Standby Backlighting on and Sounder on 50mA 150mA Display: 2 x 16 alphanumeric supertwist LCD, backlit Sounder: Tone Generator Integrated Circuit. (fire alarm is loud pulsing tone; burglary/audible panic alarm is continuous tone) FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL BEING INSTALLED IN CONJUCTION WITH THIS DEVICE. FCC ID CFS8DL6160RF FCC STATEMENT This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product or, for products not having an Ademco date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Ademco factory service. For warranty service, return product transportation prepaid, to Ademco Factory Service, 170 Michael Drive, Syosset, New York 11791. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the products will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on this product. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. 165 Eileen Way, Syosset, NY 11791 Copyright 2002 PITTWAY CORPORATION i.¢l K0903ax 9/02
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Create Date : 1910:20:90 61:12:65 Producer : Acrobat Distiller 3.02 Creator : PSCRIPT.DRV Version 4.0 Title : Microsoft Word - K0903.docEXIF Metadata provided by EXIF.tools