Ademco 8DLPHS8-US GSM/GPRS/UMTS/HSPA Module Cartridge User Manual Info Rev E
Honeywell International Inc. GSM/GPRS/UMTS/HSPA Module Cartridge Users Manual Info Rev E
Ademco >
Users Manual Info Rev E
SEE BOTTOM OF PAGE 2 FOR AGENCY STATEMENTS 3G Communicator Lyric-3G / Lyric-3GC Installation Instructions General Information The Lyric-3G/Lyric-3GC Communication Modules allow the Lyric Controller to communicate with the Central Station via the 3G cellular network. IMPORTANT: Before installing the communication module, make sure power (both AC and battery) is removed from the controller or use the “Install Cellular Module” mode described in the Replacing the Module section below. Installing the Lyric-3G Module PR N EL E IM YW IN E AR LL 1. Install the provided FCC/IC label (P/N 800-19687) on the control’s case back. 2. Remove bezel from right-hand side of control to expose the radio module slot. To remove the bezel, push upward then slide it out. 3. Insert the module into the slot. Push firmly to mate the edge connector. Install the securing screw to ensure proper connection and operation. 4. Replace the bezel. 5. After all other controller connections are made, power up the controller. 6. Program and register the module during the controller’s initial association with its AlarmNet 360 account. Refer to the controller’s Programming Guide for details. 7. Check the signal strength before permanently locating the Lyric Controller. See Checking Signal Strength section. Removing the Bezel Replacing the Module Typical FCC/IC Label Location Installing the Lyric-3G Module In the event the module needs to be replaced, the Control must first be put in module replacement (“Install Cellular Module”) mode to avoid causing a tamper alarm or damaging the module. Module replacement mode deactivates tamper protection and removes power from the module connector for about 15 minutes. 1. Select the Install Cell button. User: Security –Tools – user code – Advanced – Install Cellular Module Installer: Security –Tools – installer code – Test – Install Cellular Module a. Select Yes at the prompt to continue. b. A popup window displays steps for module replacement. Keep this window open until replacement is completed 2. Remove the side bezel. See diagram at right. 3. Remove the screw that secures the module. 4. Remove the communication module from its connection slot by using the pull tab. 5. Insert the new module into the slot. Push firmly to mate the edge connector. Replace the screw. 6. Replace the bezel. 7. When installation is complete, press OK at the replacement steps window. Confirmation of proper installation appears. Press OK to exit. Checking Signal Strength When choosing a suitable mounting location, check the communicator’s signal strength to ensure proper operation. For most installations, using the module’s internal antenna, mounting the Lyric controller as high as practical, and avoiding large metal components provides adequate signal strength for proper operation. Signal Strength Guide RSCP (3G) – if module is using the 3G Network Good......... -20 to -90 dBm OK ............. -91 to -100 dBm Marginal .. -101 to -106 dBm Bad ............ -107 to -120 dBm Use the Lyric Controller “Cellular Information” screen to display signal strength (in dBm): RSSI (2G) – if module is using the 2G Network Good......... -20 to -89 dBm OK ............. -90 to -98 dBm Marginal .. -99 to -104 dBm Bad ............ -105 to -120 dBm Security – Tools – [installer code] – Program – Comm. Diagnostics – Cellular Information If adequate signal strength cannot be achieved, an external antenna should be used. Use external antenna kit model Cell-ANTST. PR N EL E IM YW IN E AR LL Compare the RSCP (received signal code power [3G]) or RSSI (received signal strength indicator [2G]) number displayed to the Signal Strength Guide at right to ensure adequate signal strength. If necessary, relocate the Controller to obtain better signal strength (press Cellular Information again to refresh the reading). Specifications Dimensions: .... 2-5/8”W x 3-1/8”L x 1/2”D Voltage Input .. 5V (provided by the controller) Current Idle ............... 60mA, standby Transmit ..... 500mA Environmental Operating temperature: -20ºC to +55ºC, (for compliance agency: 0ºC to +49ºC) Storage temperature: -40º to +70ºC Humidity: 0 to 95% relative humidity, non-condensing (for compliance agency 0% to 85%) Frequency Bands: 2G GSM/GPRS/EDGE Quad Band 850/900/1800/1900 MHz 3G UMTS Band V, Band II 850/1900MHz WCDMA HSUPA HSDPA SUPPORT & WARRANTY For the latest documentation and online support, please go to: https://mywebtech.honeywell.com/ For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa. MyWebTech Warranty RF Exposure Warning The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 7.8 in (20 cm) from all persons and must not be co-located or operated in conjunction with any other transmitter except in accordance with FCC multi-transmitter product procedures. Mise en Garde Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes. External Antenna Kit: Cell-ANTST FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC CLASS B STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • If using an indoor antenna, have a quality outdoor antenna installed. • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS-210 of IC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. IMPORTANT NOTE ABOUT EXTERNAL ANTENNAS If an external cellular radio antenna is used, the antenna may be installed or replaced ONLY by a professional installer. Ê800-19181@Š 800-19181 4/15 Rev. A TO THE INSTALLER For the Lyric-3G, the external antenna must not exceed a maximum directional gain (including cable loss) of 6.0 dBi at 850 MHz and 2.5 dBi at 1900 MHz. 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2015 Honeywell International Inc. www.honeywell.com/security
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Create Date : 2015:05:29 16:11:38-04:00 Modify Date : 2015:06:23 17:47:54-04:00 Has XFA : No Language : EN-US XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2015:06:23 17:47:54-04:00 Creator Tool : Acrobat PDFMaker 11 for Word Document ID : uuid:dbea6825-ee01-4800-9af4-b6149b26ccea Instance ID : uuid:ebb05d9f-1df3-44c7-9c90-cada241be9d9 Format : application/pdf Title : Creator : Producer : Adobe PDF Library 11.0 Page Layout : OneColumn Page Count : 2EXIF Metadata provided by EXIF.tools