Advance Security R42 Car Alarm Receiver User Manual 7920PINS qxp
Advance Security Inc Car Alarm Receiver 7920PINS qxp
Users Manual
For Technical Assistance Call: (800) 638-3600 I N S TA L L AT I O N I N S T R U C T I O N S Model: 7921P Step 1: 10-Pin Main Harness Installation The main wire harness contains 8 wires which all have a specific purpose. Follow the wiring recommendations enclosed for each wire. Wires not used should be released from the harness connector or taped off to prevent accidental shorting. Gray Wire: The gray wire is a pulsed ground output designed to activate the vehicle’s existing car horn system in place of or in addition to a siren sounding device. Connect the gray wire to the negative trigger wire on the vehicle’s horn relay. Step 3: 5-Pin Power Harness Installation The power harness contains 3 wires and two vacant sockets, this power harness does not come packaged with the alarm module but in 5901H1, 5901H2, 5901H3 harness kits or custom starter disable/power interface harnesses. Packaged with the 10-pin main harness are two loose wires (an Orange wire and a White wire with a Black stripe). Follow the wiring recommendations enclosed for each wire. Power Harness WARNING! Maximum output of this wire is 300mA. Horn systems requiring positive voltage or more than 300mA to trigger the horn relay will require an additional relay to increase current capabilities. Blue Wire with White Stripe: This wire provides a single pulsed ground when the 7921P is disarmed so that it will disarm a factory installed alarm system. Note: Some factory alarms systems may require a double pulse signal to disarm the factory alarm system. In this case, you will need to add Silencer adapter model #5902DP to the blue wire with white stripe. First Socket (-) Domelight control output Second Socket (+) 12 volts for the relay Orange Wire: Insert the orange wire into the first socket of the power harness. The orange wire is the dome light supervision control output. Connect the orange wire to the required control relay. Brown Wire: The brown wire is the positive siren output wire. Connect the brown wire from the harness to the brown wire on the siren supplied. Ground the remaining black wire from the siren. White Wire with Black Stripe: Insert the white/black wire into the third socket of the power harness. (As shown) The white/black wire is the (-) Channel #2 output wire and should be connected to an existing (-) activated trunk release switch or an additional relay will have to be added to control the trunk release mechanism. Blue Wire: The blue wire is a negative trigger input that can be used for existing or newly installed grounding type hood/trunk/ hatch pin switches. The blue wire can also be used as an input for additional ground output electronic sensors. Step 4:Door Lock/Unlock Socket (3- Pin Black Socket) For remote controlled door lock/unlock operation, follow the wiring diagram enclosed (page 2). The harness is an optional part not supplied with 7921P. Order part # 5902 or 5903 for one-wire multiplexing door locking systems. Green Wire: The green wire is the negative (-) door trigger input. If the vehicle you are working on has a negative (-) triggered dome light system, connect the green wire to the common dome light trigger wire. This wire is usually located at the driver’s side door jamb switch. Step 5: Auxiliary Interrupt Wiring (2-Pin Orange Socket) To interrupt an additional circuit(s), all alarm modules require either the ALARPS, ALA-RPS2 or ALA-RPS3 relay pack. Follow the wiring instructions supplied with the relay packs. Violet Wire: The violet wire is the positive (+) door trigger input. If the vehicle you are working on has a positive (+) triggered dome light system, connect the violet wire to the common dome light trigger wire. This wire is usually located at the driver’s side door jamb switch. Step 6: Dip Switch Feature Programming Dip Switch #1: Ignition Key Controlled Lock/Unlock (Door lock control function must be connected and the door lock output feature must be “On” in the dealer mode) Note: This feature can be programmed using the #1 Dip Switch in both the dealer and consumer modes. Place Dip Switch #1 to the “On” position to activate this feature. Place Dip Switch #1 in the “Off” position to deactivate this feature. Red Wire with White Stripe: The red/white wire is the output of the parking light relay. Connect the red/white wire to the parking light trigger wire coming from the headlight switch. Do not connect the red/white wire to a dashboard lighting wire. Connecting the red/white into dashboard lighting can damage the dashboard lighting dimmer switch. Pink Wire: The pink wire is the input wire to the parking light relay. The connection of the pink wire determines the output polarity of the parking light relay. If the parking light system you are connecting to is positive activation, connect the pink wire to battery +12vdc. If the parking light system you are connecting to is negative activation, connect the pink wire the the frame of the vehicle. Note: (Applies to All Models) The main 10 pin harness contains two vacant sockets. These vacant sockets are for channel #2 output. All the alarm modules require an 5912 for channel #2 operation. Follow the wiring instructions supplied with 5912. If a 5912 relay is not available, a standard Bosch 5 pin relay can be used. Main Harness Dip Switch #2: Current Sensing Note: This feature can be programmed using the #2 Dip Switch in both the dealer and consumer modes. Place Dip Switch #2 to the “On” position to have the current sensing feature on. Place Dip Switch #2 in the “Off” position to have the current sensing feature off. Dip Switch #3: Door Entry Delay Note: This feature can be pre-programmed in dealer mode using the #3 Dip Switch. The feature will not be functional in the dealer mode but will become functional when the unit is converted to customer mode. Place the dip switch in the "On" position. During customer mode operation, the (+) or (-) door input trigger wires will have a 20 second entry delay. This is primarily used for Ford vehicles that have keyless entry and use a door mounted keypad. Place the dip switch in the "Off" position (Factory Default) and the 20 second door entry delay will be off (Instant Activation). Vacant Sockets +12 Volts for Relay (when needed) (-) Channel #2 Output Step 7: Additional Menu Programming The Silencer model 7921P control module offers additional menu programmable features. Follow the dealer or consumer remote feature programming sheets to adjust the 7921P features. Step 2: Arm / Disarm Harness Wiring (3-Pin White Socket) Follow wiring diagram enclosed for proper connection to the factory installed power door locking system to arm and disarm the 7921P security system. 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Proposed © 2005 Copyright Magnadyne Corp. INSTALLATION INSTRUCTIONS LED (White 2-Pin Socket) Model: 7921P Valet Switch (Blue 2-Pin Socket) Arm/Disarm Harness (White 3-Pin Socket) DIP Switches Gray Wire Horn (-) Pulsed Output Blue/White Wire (-) Signal Output to Disarm Factory Alarm 7921P Controller Ignition Locking** (Black 3-Pin Socket) Programmable Key (Green 2-Pin Socket) Brown Wire Positive (+) Output for an Optional Electronic Siren Auxiliary Interrupt (Orange 2-Pin Socket***) Blue Wire Negative Pin Trigger Input Green Wire Negative Door Trigger Input Violet Wire Positive Door Trigger Input Shock Sensor (White 4-Pin Socket****) White/Black Wire Channel #2 Output 5-Pin Power Harness* Red/White Wire Parking Lights Relay Output Red Wire (Lock) Orange Wire ***** 2nd Unlock Output (requires additional relay & special wiring). Black Wire (Unlock) Pink Wire Parking Lights Relay Input Starter Disable Socket* Left Door Lock/Unlock Switch Green Wire White Wire Blue Wire Supplied with 5901H1, 5901H2 or 5901H3 Harness Kits or Custom Starter/Disable T-harness. ** Supplied with 5902 Ignition Controlled Locking Kit. *** Supplied with ALA-RPS, ALA-RPS2 or ALA-RPS3 relay packs. Programmable Key Receptacle for Changing to Customer Mode or Putting Unit to Sleep Mode **** For a Single-Zone Shock Sensor use ALA930. For a Dual-Zone Shock Sensor use ALA95 or ALA90. ***** This wire supplies +12V power, if not used cut this wire off at connector to prevent shorting. A = Possible Connection Points for Green Wire B = Connection Point for Blue Wire C = Possible Connection Points for White Wire Optional 5902 Harness Left Door Jamb Lock Right Door Jamb Lock Factory Keyless Module (Typical) Unlock Unlock Right Front Pass. Door Driver's Door Lock (+) Unlock (+) Lock (+) Unlock (+) Inside Door Unlock (+) Right Rear Pass. Door Left Rear Pass. Door Lock (+) Right Door Lock/Unlock Switch Inside Vehicle Lock (+) Unlock (+) Inside Door Proposed © 2005 Copyright Magnadyne Corp. Models: 7921P, 7920P, 7919P Rev. C C O N S U M E R R E M OT E F E AT U R E P R O G R A M M I N G NOTE: The alarm must be in “consumer mode” before you can program consumer mode features. See additional instruction sheets on performing this function. When the alarm is programmed to consumer mode, a specific group of operating features are reset to their default settings. These default settings can be changed by following the enclosed procedures and using the special 7910P programming transmitter. NOTE: In the event that the 7910P transmitter is unavailable, the programming can also be performed by the consumer transmitter once all buttons have been programmed into the control module memory. (See “Consumer Remote Feature Programming from the Consumer's Transmitter.) To get into the “Consumer Remote Feature Programming” mode follow the procedures below”. Programmable Alarm Feature Default Setting (Consumer Transmitter Mode) (Consumer Transmitter Mode) Chirp Status Indicator 2A *Mode “P” Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” 2B *Mode “S” Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “On” Starter Disable will Arm 70 Seconds After Last Door is Closed Chirps On Remote Panic from Factory Keyless Entry Transmitter On Safety Illumination Sentinel System Off * During Dealer Remote Feature Programming either the ”P” or “S” mode was selected. In the Consumer Remote Feature Programming mode you cannot change the mode (either “S” or “P”) that was selected in the Dealer Feature Programming. You can change the features of the mode that was selected in the Dealer Mode. (See Step 5 for more details.) To change mode “S” or “P” operation you have to recode a dealer transmitter to the unit and change the operation in the “Dealer Remote Programmable Feature” Mode. Step 1 Step 2 Step 3 Dealer Switch (Red Button) Disarm Security System Consumer Switch (Black Button) Momentary Switch Push On / Off Turn On Ignition The LED will remain off. The LED will be off and the horn / siren will emit 2 chirps. ON OFF Toggle Switch Push Once = On Push Again = Off ☛ ON ☛ Insert the Valet Switch Step 4 Push the Valet Switch: 6 Times if Using a Red Button Switch 12 Times if Using a Black Button Switch (Represents 6 Times On / Off) The LED will be on solid and the horn / siren will emit 1 long then 1 short chirp. You are now in the “Consumer Remote Feature Programming” mode. Step 5 5910P Programming Transmitter Blue Button Black Button Step 6 Use the 5910P transmitter and the chart below to change the features as required. Press and hold the button that controls the function you want to change and listen for the chirp confirmation. You can repeatedly press the same colored button and turn the same function on and off as many times as required until the operation is correct. After all functions have been re-programmed to operate as required go to step 6. Red Button Button Color Function Black Chirp Status Indication OFF Turn Off the Ignition The horn / siren will emit 1 short chirp and 1 long chirp. You are now out of the “Consumer Remote Feature Programming” mode. Confirmation = Change Function 1 Beep = Chirp Status Indication “On” 2 Beeps = Chirp Status Indication “Off” 2A Blue 1 Beep = Mode “P” Note: The auto arm door locking feature has a default setting of "off" in customer mode. To turn on or off the auto arm door locking feature in customer mode, repeat the steps for the "Blue" button and hold the transmitter button down for more than 3 seconds to get a second confirmation chirp. For example: (1 chirp = 10 sec auto arm on, auto door lock off.) (1 chirp + 1 chirp = 10 sec auto arm on, auto door lock on.) Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 10 seconds after last door is closed or rearm 10 seconds after remote disarm. 2 Beeps = Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 20 seconds after last door is closed or rearm 20 seconds after remote disarm. 3 Beeps = Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 45 seconds after last door is closed or rearm 60 seconds after remote disarm. 4 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “On” The starter will disable 70 seconds after last door is closed. 5 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “Off” 2B Blue Mode “S” Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 45 seconds after last door is closed. 2 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “On” The starter will disable 70 seconds after last door is closed. Red Remote Panic from Factory Keyless Entry Transmitter 1 Beep = Panic “On” 2 Beeps = Panic “Off” Black + Blue Safety Illumination Sentinel System 1 Beep = 3 Beeps = Safety Illumination Sentinel System “On” 4 Beeps = Safety Illumination Sentinel System “Off 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Proposed © 2005 Copyright Magnadyne Corp. Consumer Remote Feature Programming (7921P, 7920P, 7919P Rev. C) REMOTE FEATURE PROGRAMMING USING THE CONSUMER’S TRANSMITTER ARM/DIS AUX ARM/DIS AUX LOCK AUX UNLOCK AUX UNLOCK LOCK UNLOCK PANIC AUX AUX ARM/DIS LOCK PANIC Button Function Confirmation = Change Function ARM/DIS or LOCK Chirp Status Indication and Single/ Dual Unlock Outputs 1 Beep = Chirp Status Indication “On” 2 Beeps = Chirp Status Indication “ Off” 2A AUX (2-Button) or Mode “P” 1 Beep = TRUNK (3-Button) or UNLOCK Note: The auto arm door locking feature has a default setting of "off" in customer mode. To turn on or off the auto arm door locking feature in customer mode, repeat the steps for the "Blue" button and hold the transmitter button down for more than 3 seconds to get a second confirmation chirp. For example: (1 chirp = 10 sec auto arm on, auto door lock off.) (1 chirp + 1 chirp = 10 sec auto arm on, auto door lock on.) Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 10 seconds after last door is closed or rearm 10 seconds after remote disarm. 2 Beeps = Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 20 seconds after last door is closed or rearm 20 seconds after remote disarm. 3 Beeps = Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 45 seconds after last door is closed or rearm 60 seconds after remote disarm. 4 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “On” The starter will disable 70 seconds after last door is closed. 5 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “Off” 2B AUX (2-Button) or Mode “S” 1 Beep = Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” Both will arm 30 seconds after last door is closed. 2 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “On” The starter will disable 70 seconds after last door is closed. UNLOCK Red Button on 5910P Only Remote Panic from Factory Keyless Keyless Transmitter 1 Beep = Panic “On” 2 Beeps = Panic “Off” ARM/DIS (2-Button)+ AUX (2 Button) or Safety Illumination Sentinel System 3 Beeps = Safety Illumination Sentinel System “On” 4 Beeps = Safety Illumination Sentinel System “Off” LOCK + UNLOCK FEATURE PROGRAMMING USING THE CONTROL MODULE’S DIP SWITCHES The Silencer model 7921P control module offers 3 programmable features. Follow the instructions enclosed to program these features using the Dip switches in the control module. ® Dip Switch #1: Ignition Key Controlled Lock/Unlock (Door lock control function must be connected and the door lock output feature must be “on” in the dealer mode) Note: This feature can be programmed using the #1 Dip switch in both the dealer and consumer modes. Place Dip switch #1 to the “On” position to activate this feature. Place Dip switch #1 in the “Off” position to deactivate this feature. Back View of Housing Dip Switch #2: Current Sensing Note: This feature can be programmed using the #2 Dip switch in both the dealer and consumer modes. ON Dip Switches Place Dip switch #2 to the “On” position to have the current sensing feature on. Place Dip switch #2 in the “Off” position to have the current sensing feature off. Difference Between if a Dip Switch in Off or On #2 Dip Switch in the “Off” Position #2 Dip Switch in the “On” Position Dip Switch #3: Door Entry Delay (Applies to 7921P only) Note: This feature can be pre-programmed in dealer mode using the #3 dip switch. The feature will not be functional in the dealer mode but will become functional when the unit is converted to customer mode. Place Dip switch #3 in the "on" position. During customer mode operation, the (+) or (-) door input trigger wires will have a 20 second entry delay. This is primarily used for Ford vehicles that have keyless entry and use a door mounted keypad. Place Dip switch #3 in the "off" position (Factory default) and the 20 second door entry delay will be off (Instant Activation). 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Proposed © 2005 Copyright Magnadyne Corp. Models: 7921P, 7920P, 7919P Rev. C D E A L E R R E M OT E F E AT U R E P R O G R A M M I N G When the Silencer security system control module learns the dealer transmitter operating code, a specific group of features are automatically programmed to their default settings. Enclosed, is a chart of the default settings for dealer transmitter operation. Programmable Feature Single/Dual Unlock Pulses Automatic Arm Door Locking (See Note 1) On Chirp Status Indicator (See Note 2) On These default setting can only be changed by following the enclosed procedures and using the special 5910P programming transmitter (Shown Below). Consumer Remote Feature Programming Modes for Automatic Mode “P” Arming of Alarm and Automatic Arming of Starter Disable. ( See Step 5 and Note 3 for Full Details) Note: Pre-programming the “P and S” type auto arming modes is for use when the system is put into consumer mode only. In dealer mode, auto arming is on without On/Off programming and auto arm locking is on but can be programmed off as explained below. ® To get into the “Dealer Remote Feature Programming” mode repeat the following procedures: Step 1 Step 2 Insert the Valet Switch Consumer Switch (Red Button) (Black Button) Single Step 3 ☛ Dealer Switch Default Setting Step 4 Disarm Security System Turn On Ignition The LED will be off and the horn/ siren will emit 2 short beeps. ON OFF Momentary Switch Toggle Switch Push On/Off Push it On then Push it again for Off ☛ ON Push the Valet Switch: 4 Times if Using a Red Button Switch 8 Times if Using a Black Button Switch (Represents 4 Times On / Off) The LED will be on solid. The horn/ siren will emit 1 long then 1 short beep) You are now in the “Dealer Remote Feature Programming” mode. Step 5 5910P Programming Transmitter Black Button Blue Button Step 6 Use the 5910P transmitter and the chart below to adjust the features as required. Press the button that controls the function you want to change and listen for the chirp confirmation. You can repeatedly press the same colored button and turn the same function on and off as many times as required until the operation is correct. After all functions have been re-programmed to operate as required go to step 6. OFF Red Button Button Color Black Changed Function Single or Dual Unlock Outputs Confirmation Blue Dealer Mode Auto Arm Door Locking Pre-Programmed Consumer Mode Auto Arm Red ** Black + Blue Chirp Status Indicator On/Off Selects “P” or “S” Mode Operation ** Note: The Black +Blue Buttons Change Automatic Alarm Arming of Alarm and Automatic Arming of Starter Disable in the Consumer Mode Only! Default Dealer Mode Operation is Always: Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On” and Automatic Door Locking “On”. Note 1: When transmitter operation is changed from a dealer transmitter to a consumer transmitter the automatic arm locking feature will default to “OFF”. This feature can be programmed on in the customer mode by following the consumer feature programming chart. 1 Beep = Single Unlock Pulse 2 Beeps = Dual Unlock Pulses 1 Beep = Automatic Arm Door Locking On, Consumer Auto Arm is ON 2 Beeps = Automatic Arm Door Locking OFF, Consumer Auto Arm is ON 3 Beeps = Automatic Arm Door Locking On, Consumer Auto Arm is OFF 4 Beeps = Automatic Arm Door Locking OFF, Consumer Auto Arm is OFF 1 Beep = On, 2 Beeps = Off 4 Beeps = Mode “P” (See 2A Consumer Programming) Automatic Arming of Alarm is “Programmable” and Automatic Arming of Starter Disable is “Programmable” in Consumer Mode Only. 3 Beeps = Mode “S” (See 2B Consumer Programming) Automatic Arming of Alarm is “Programmable” in Consumer Mode. Automatic Arming of Starter Disable is Always “On” and is “Not Programmable” in Dealer or Consumer Mode. Note 2: When transmitter operation is changed from a dealer transmitter to a consumer transmitter the horn/siren and chirp indicator will return to an “on” condition. 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Turn Off the Ignition The LED will be off and the horn / siren will emit 1 short beep and 1 long beep. You are now out of the feature programming mode. Note 3: When transmitter operation is changed from a dealer transmitter to a consumer transmitter, the automatic arming of alarm and automatic arming of starter disable (Mode “S” or “P”) will remain as programmed in the dealer transmitter mode. In order to change Mode “S” or Mode “P” operation, you have to re-code a dealer transmitter to the unit and change the operation in the dealer remote programmable feature mode. Proposed © 2005 Copyright Magnadyne Corp. Models: 7921P, 7909P, 7905P 6900P, 6900P-2, 6905P, 6909P WA K I N G Step 1 U P U N I T F R O M T H E Step 2 Step 3 ON Insert the Valet Switch Dealer Switch Consumer Switch (Red Button) (Black Button) “ S L E E P Turn On Ignition ☛ Push the Valet Switch 3 Times for Red Button 6 Times for Black Button (Represents 3 Times On/Off) ON OFF Momentary Switch (Push On/Off) A. Long horn chirp indicates the unit is in code learning mode. Toggle Switch (Push On then push it again for off) Step 5 OR Remove the Dealer or Customer Key M O D E ” Step 4 OR Insert a Dealer or Customer Key A. Horn chirps once to indicates the code has been learned. B. LED starts flashing slowly to indicate the code has been learned. B. LED comes on indicating the unit is in code learning mode. Step 6 OFF Turn Off Ignition A. Horn chirps 1 short then 1 long to indicates you have exited code learning. B. LED starts flashing slowly. 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Proposed © 2005 Copyright Magnadyne Corp. Models: 7921P, 7909P, 7905P 6900P, 6900P-2, 6905P, 6909P P R O G R A M M I N G T H E U N I T TO “ S L E E P M O D E ” In the event the customer declines to purchase the Silencer security system and the system is not going to be removed from the vehicle, it must be put into “Sleep” mode to prevent automatic arming. The white sleep key can also be used to delete a dealer code and to reset the security system to it’s original state as it was received from the factory. Note: The system must be in dealer mode to use the white key. If the system is armed, you should disarm it with the dealer key to prevent triggering. Step 1 Step 2 Step 3 ON Insert the Valet Switch Dealer Switch Consumer Switch (Red Button) (Black Button) Turn On Ignition Insert the White “Sleep” Key into the Receptacle Step 4 ☛ Push the Valet Switch 6 Times for Red Button 12 Times for Black Button (Represents 6 Times On/Off) ON OFF A. The LED will flash 6 times. Momentary Switch (Push On/Off) B. 6900P, 6900P-2 or 6905P: If the 5911 buzzer is installed, it will emit 6 beeps. Toggle Switch (Push On then push it again for off) Step 5 6909P: The horn/siren will emit 6 beeps. Also the parking lights will flash 6 times. Step 6 OFF Remove the White “Sleep” Key Turn Off Ignition A. The LED will be off. You are now in the “Sleep” mode. 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Proposed © 2005 Copyright Magnadyne Corp. Models: 7921P, 7909P, 7905P 6900P, 6900P-2, 6905P, 6909P DELETING THE DEALER OR CONSUMER KEY Upon the customer purchasing the 6905P or 6909P, it will arm/disarm from the factory keyless remotes. He/she also has the option of purchasing a customer key pack (5900PKP) to disarm the security system. In the event the customer declines to purchase the customer Key Pack (5900PKP) the dealer key code “must” be deleted. This is done by programming in the bright orange “dealer delete key”. If the customer declines to purchase the customer key pack for the 6909P, but still wants the unit to automatically arm; see 6909P Feature Programming to activate this feature. Step 1 Step 2 Step 3 Step 4 OR ON Disarm the Security System Turn On Ignition Insert the Valet Switch Dealer Switch Consumer Switch (Red Button) (Black Button) Insert the Orange “Delete Code” Key into the Receptacle ON OFF Momentary Switch (Push on/off) Step 5 Toggle Switch (Push on then push it again for off) Step 7 Step 6 OF F ☛ Push the Valet Switch 6 Times for Red Button 12 Times for Black Button Remove the Orange “Delete Code” Key (Represents 6 Times On/Off) Turn Off Ignition A. The LED will be off. (6905P and 6909P) You have now deleted all key codes. B. The horn/siren/chirper will emit 1 short and 1 long chirp. A. The LED will flash 6 times. (6905P and 6909P) Note: When dealer or consumer key code is deleted the security system will be in the consumer mode.. B. 6905P: If the 5911 buzzer is installed, it will emit 6 beeps. 6909P: The horn/siren will emit 6 beeps. Also the parking lights will flash 6 times. 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Proposed © 2005 Copyright Magnadyne Corp. Models: 7921P, 7909P, 7905P 6900P, 6900P-2, 6905P, 6909P C O N S U M E R Step 1 K E Y Step 2 Step 3 ** OR C O D I N G Step 4 OR ON Insert the Valet Switch Dealer Switch Consumer Switch (Red Button) (Black Button) ON OFF Momentary Switch (Push On/Off) Insert the Dealer Key Remove the Dealer Key Turn On Ignition Step 7 Step 8 * Model: 5910K ** Model: 5900-DB (Blue Key) 5900-DG (Green Key) 5900-DR (Red Key) 5900-DY (Yellow Key) Toggle Switch (Push On then push it again for off) Step 5 Step 6 OF F ☛ Push the Valet Switch 3 Times for Red Button 6 Times for Black Button (Represents 3 Times On/Off) A. Long horn chirp indicates the unit is in code learning mode. ☛ *** Insert the Customer Key Remove the Customer Key A. Another short horn chirp indicates the key code was learned. Note: The system will automatically exit code learning if a key is not inserted within 15 seconds. Turn Off Ignition A. A short and long horn chirp indicates you have exited code learning. *** Model: 5900PKP Note: The dealer key will be erased when programmed to the customer key. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions. 1)•This device may not cause harmful interference, and 2)•This device must accept any interference received, including interference that may cause undesired operation. Per FCC 15.21, you are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 1111 West Victoria Street Compton, CA 90220 www.magnadyne.com Proposed © 2005 Copyright Magnadyne Corp.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Creator : QuarkXPress(tm) 6.0 X Press Private : %%DocumentProcessColors: Cyan Black.%%MarksAllSeparations: true.%%EndComments Create Date : 2004:12:14 16:39:42Z Modify Date : 2005:02:14 15:42:50+08:00 Page Count : 9 Creation Date : 2004:12:14 16:39:42Z Producer : QuarkXPress(tm) 6.0 Mod Date : 2005:02:14 15:42:50+08:00 Metadata Date : 2005:02:14 15:42:50+08:00 Title : 7920PINS.qxp Has XFA : NoEXIF Metadata provided by EXIF.tools