Aeon Labs DSB54-ZWUS RECESSED DOOR SENSOR User Manual Recessed Door Sensor manual 2CDR

Aeon Labs LLC. RECESSED DOOR SENSOR Recessed Door Sensor manual 2CDR

User Manual

Recessed Door SensorView the expanded manual: http://aeot.ec/spprt/recessedFrom Aeotec by Aeon Labs' Intelligence series comes the  Recessed  Door  Sensor.  Invisibly  installed,  it  sits within  a  door  and  its  frame  to  provide  all  the information  needed  by  a Z-Wave system  for  security, safety, and ambiance, and it does it all without altering a room's aesthetics.Your Recessed Door Sensor is comprised of two parts: the  larger  Main  Sensor  and  the  smaller  Magnetic Sensor.The larger Main SensorSeparate  the  Main  Sensor's  two  sections  by  first removing  its  lid  and  then  removing  its  internal components.Remove the  clear  battery  insulator  by  pulling  it  away from the Main Sensor.Install  your  Recessed Door SensorWith  the  Main  Sensor  powered  and  activated,  it  is  now time to inlay it within your selected doorframe and to also install the Magnetic Sensor. Top of the doorSide of the doorPrepare a space for the Main Sensor by drilling a hole into  your  doorframe  using  a  19mm  wide  drill  bit.  The hole should be 65 mm deep.Step 165mm deep 19mmDrill bitDrill a corresponding hole in your  door. The hole should  be 15 mm deep. As stated, the position of this hole should align exactly with the one hole you just created in the doorframe. Again, use a 19mm wide drill bit.Step 215mm deep19mmDrill bitDoorframeDoorInsert  the  Main  Sensor  into  the  hole  you  created  in  the doorframe then secure it  using two screws.Step 3With  your  door and doorframe  prepared and the drill  holes created, it's now time to mount both parts of your Recessed Door Sensor.Secure with screws DonePlace  a  small  amount  of  white  glue  (PVA)  inside  the  hole you created for the Magnetic Sensor. Then place the sensor over  and  into  the  hole, and insert  it  by tapping gently  on  it with a rubber hammer.Step 4Tap with hammer Done13Aeotec Recessed Door Sensor2Familiarise yourself with your door sensor Main SensorLEDScrew  HoleZ-Wave Button HoleMagnetic SensorThe Magnetic SensorA magnet in the plastic shellUsing  a  slot-head  screwdriver,  remove  the  Main Sensor's  lid  by    pressing gently against its exposed connector.Quick Start The  installation  of  your  Recessed Door  Sensor  has  two major steps:  the  installation  of the Main Sensor and the insta llation  of  the  Magne t ic  Se nsor.  Power ed  by batteries,  your  door sensor will use wireless  technology to talk to your Z-Wave network once installed.Prepare the Main Sensor The first step in installing your Recessed Door Sensor is to activate the Main Sensor.1.2.3.With  the  battery  insulator  removed,  reinsert  the internal components into the Main Sensor's enclosure before  reattaching  its  lid.  The  Main  Sensor  will  now look as it did prior to step 1.4.Note:  Ensure  that  the  Main  Sensor's  button  aligns  with the button hole of its lid.Before  beginning  it  is  important  to  select  a  suitable position for your Recessed Door Sensor. For the following instructions, your Recessed Door Sensor should be:Installed at the top of a door or the side of door.Positioned  away  from  metal  that  could  interfere  with its  magnetic  functionality.  This  includes  your  door's plate, handle or lock mechanism.Installed  in  a  suitable  location  to  ensure  a  clear(at least 1mm) separation when the door is closed.Positioned exactly above or beside the hole you'll later in your door for the installation of the Magnetic Sensor.The rectangular areas highlighted above are the most appropriate installation positions.The gap between the two parts of your sensor must be at least 1mm. If they are not, re-affix the Main Sensor potentially by altering its hole.  Step 5MagneticSensorMain Sensor1mmMagneticSensorMain SensorScrew  Hole
RemoveOperating  distance:  Up  to  100  feet  /  30  meters  indoors and 300 feet / 100 meters outdoors.Battery: lithium cell CR2, 3 volt battery, 800mAh. Operating temperature: -10℃ to 60℃.Relative humidity: 8%~80%.Aeon Labs warrants to the original purchaser of Products that  for  the  Warranty  Period  (as  defined  below),  the Products  will  be  free  from  material  defects  in  materials and  workmanship. The foregoing warranty is subject to the proper installation, operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer.  Warranty claims must be made by Customer in writing within thirty (30)  days of  the  manifestation  of  a  problem. Aeon Labs' sole  obligation  under the foregoing  warranty is, at Aeon Labs' option, to repair, replace or correct any such defect that was present at the time of delivery, or to remove the Products and to refund the purchase price to Customer. With  your  Recessed  Door  Sensor  installed  within  a door  and  its  frame,  it's  time  to  add  it  to your  Z-Wave network. The following instructions  tell you  how  to  do this using Aeotec's Z-Stick and Minimote controllers. If you  are  using  other  products  as  your  main  Z-Wave controller,  please  refer  to  the  part  of  their  respective manuals that tells you how to add new devices to your network.If  your  Z-Stick  is  plugged  into  a  gateway  or  a computer, unplug it.Take  your  Z-Stick  to  the  door  in  which  your Recessed Door Sensor has been installed.Press the Action Button on your Z-Stick.Press the Z-Wave Button on your Main Sensor with a small pin or toothpick.I f  y o ur  R e ce s s e d  D oo r  S e n s or  h a d  b ee n successfully  linked  to  your  network,  the  LED  light will be blinking for a few seconds. If the linking was unsuccessful,  the  LED  light  will  be  blinking  for  8 seconds before turning off.Press the Action Button on the Z-Stick to take it out of installation mode.Action ButtonAdd  your sensor to your Z-Wave network 41.2.3.4.5.6.Take  your  Minimote  to  the  door  in  which  your Recessed Door Sensor has been installed.Press the Include button on your Minimote.Press the Z-Wave Button on your Main Sensor with a small pin or toothpick.I f  y o ur  R e ce s s e d  D o o r  S e n s or  h a d  b e e n successfully  linked  to  your  network,  the  LED  light will be blinking for a few moments. If the linking was unsuccessful,  the  LED  light  will  be  blinking  for  8 seconds before turning off. Press any button on your  Minimote to take  it  out  of installation mode.Include1.2.3.4.5.Your sensor  can be  removed from your  Z-Wave network at  any  time.  You’ll  need  to  use  your  Z-Wave  network’s main  controller  to do  this. The  following instructions  tell you  how  to  do  this  using  Aeotec  by Aeon  Labs’  Z-Stick and Minimote controllers. If you are using other products as your  main  Z-Wave controller,  please  refer to the part of their respective  manuals that  tells  you how to remove devices from your network.If  your  Z-Stick  is  plugged  into  a  gateway  or  a computer, unplug it.Take your Z-Stick to your Recessed Door Sensor. Hold the Action Button on your Z-Stick for 3 seconds.Press the Z-Wave  Button  on  your Main Sensor with  a small pin or toothpick. If your  Recessed Door  Sensor  had  been successfully removed from your network, the LED light will turn off. If the removal was unsuccessful, the LED light will  be remain illuminate.Press the Action Button on your Z-Stick to take it out of removal mode.Take your Minimote to your Press the Remove button on your Minimote.Press the Z-Wave Button on your Recessed Door with a small pin or toothpick.If your  Recessed Door  Sensor  had  been successfully removed from your network, the LED light will turn off. If  the  removal  was  unsuccessful,  the  LED  light  will remain illuminate.Press  any  button  on  your  Minimote  to  take  it  out  of removal mode.Recessed Door Sensor.Sensor Removing your sensor from your Z-Wave network 51.2.3.4.5.1.2.3.4.5.Technical Sepcifications 6Warranty 7The "Warranty Period" begins on the date the Products is delivered and continues for 12 months. Any repairs under this warranty must be conducted by an authorized Aeon Labs  service  representative  and  under Aeon  Labs'  RMA policy.  Any repairs conducted by unauthorized persons shall void this warranty.Excluded  from  the  warranty  are  problems  due  to accidents,  acts  of  God,  civil  or  military  authority,  civil disturbance,  war,  strikes,  fires,  other  catastrophes, misuse,  misapplication,  storage  damage,  negligence, electrical  power  problems,  or  m o dification  to  the Products or its components. Aeon  Labs  does  not  authorize  any  person  or  party  to assume or create  for  it  any other  obligation or liability in connection with the Products except as set forth herein. Aeon  Labs  will  pass  on  to  Customer  all  manufacturers' Mat eria l war rant ies to t h e ex tent tha t the y ar e transferable,  but will not independently warrant any Material.Customer  must  prepay  shipping  and  transportation charges  for returned  Products,  and  insure  the  shipment or accept the risk of loss or damage during such shipment and  transportation.  Aeon  Labs  will  ship  the  repaired  or replacement products to Customer freight prepaid.Customer  shall  indemnify,  defend,  and  hold  Aeon  Labs and  Aeon  Labs'  affiliates,  shareholders,  directors, officers,  employees,  contractors,  agents  and  other representatives  harmless  from  all  demands,  claims, a ct i on s ,  c a u se s  o f  a c t io n ,  p r oc e ed i n gs ,  s ui t s ,  assessments,  losses,  damages,  liabilities,  settlements, judgments, fines, penalties, interest, costs and expenses (including  fees  and  disbursements  of  counsel)  of  every kind  (i)  based  upon  personal  injury  or  death  or  injury  to property to the extent any of the foregoing is proximately caused  either  by  a  defective  product  (including  strict liability  in  tort)  or  by  the  negligent  or  willful  acts  or omissions  of  Customer  or  its  officers,  employees, subcontractors  or  agents,  and/or  (ii)  arising  from  or relating  to  any  actua l  or  a lleged  infringemen t  o r misappropriation  of  any  patent,  trademark,  mask  work, copyright,  trade secret or any  actual  or  alleged violation of any other intellectual property rights arising from or in connection  with  the  products,  except  to  the  extent  that such  infringement  exists  as  a  result  of  Aeon  Labs' manufacturing processes.IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT,  INCIDENTAL,  PUNITIVE,  SPECIAL  O R CONSEQUENTIAL  DAMAGES,  OR  DAMAGES  FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER  OR ANY  THIRD  PARTY,  WHETHER  IN AN ACTION  IN  CONTRACT,  OR  TORT,  OR  OTHERWISE EVEN  IF  ADVISED  OF  THE  POSSIBILITY  OF  SUCH DAMAGES.  AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE  REMEDY  FOR  ANY  CAUSE  OF  ACTION ARISING  IN  CONNECTION  WITH  THIS  AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF  WARR ANT Y,  BR E ACH  OF  AG REEM ENT,  O R EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED TO, AT  AEON  LABS'  OPTION,  REPLACEMENT  OF,  OR REPAYMENT  OF  THE  PURCHASE  PRICE  FOR  THAT PORTION  OF PRODUCTS  WITH  RESPECT  TO  WHICH DAMAGES ARE CLAIMED.   ALL CLAIMS  OF ANY KIND ARISING  IN  CONNECTION  WITH  THIS  AGREEMENT OR  THE  SALE  OR  USE  OF  PRODUCTS  SHALL  BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE  DATE  FIXED  FOR  DELIVERY  IN  THE  EVENT  OF NONDELIVERY. THE  INDEMNITY  AND  WARRANTY  IN  ABOVE  ARE EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES, WHETHER  EXPRESS OR IMPLIED, I N C L U D I N G   T H E   I M P L I E D   W A R R A N T I E S   O F  M E R C H A N T A B I L I T Y   A N D   F I T N E S S   F O R   A  PARTICULAR PURPOSE.THE  MANUFACTURER  IS  NOT  RESPONSIBLE  FOR ANY  RADIO  OR  TV  INTERFERENCE  CAUSED BY U N A U T H O R I Z E D   M O D I F I C AT I O N S   T O   T H I S  EQUIPMENT.  SUCH  MODIFICATIONS COULD  VOID T H E  U S E R'S  A U T H OR I T Y  T O  O P ER AT E  T H E EQUIPMENT.This  device  complies  with  Part  15  of  the  FCC  Rules. Operation is subject to the following two conditions:This device may not cause harmful interference.This  device  must  accept  any  interference  received, including  interference  that  may  cause  undesired operation. This equipment has been tested and found to  comply  with  the  limits  for  a  Class B  digital device, pursuant to part 15 of the FCC Rules. These limits are designed  to  provide  reasonable  protection  against harmful  interference  in  a  residential installation.  This equipment  generates,  uses  and  can  radiate  radio frequency  energy  and,  if  not  installed  and  used  in accordance  with  the  instructions,  may cause  harmful interference to radio communications. However, there is  no  guarantee  that  interference  will  not  occur  in  a particular  installation.  If  this  equipment  does  cause harmful  interference  to  radio  or  television  reception, which can be determined by turning the equipment off and  on,  the  user  is  encouraged  to  try  to  correct  the int erfe renc e  b y  o ne  o r  m ore  o f  t he  f ollo wing measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment  into  an  outlet  on  a  circuit   di f fere nt  f rom  t hat  t o  w hich  th e  r ecei ver  i s connected.Consul  the  dealer  or  an  experienced  radio/TV technician for help.1.2.FCC NOTICE(for USA)Do  not  dispose  of  electrical  appliances  as  unsorted municipal waste, use separate collection facilities.Contact your local government for information regarding the collection systems available.WarningVersion:501005400001-AA www.aeotec.comIf you’re using a Minimote:If you’re using a Z-Stick:If you are using a Minimote:If you are using a Z-Stick:Certifications (regional):

Navigation menu