Aeon Labs DSB54-ZWUS RECESSED DOOR SENSOR User Manual Recessed Door Sensor manual 2CDR

Aeon Labs LLC. RECESSED DOOR SENSOR Recessed Door Sensor manual 2CDR

User Manual

Download: Aeon Labs DSB54-ZWUS RECESSED DOOR SENSOR User Manual Recessed Door Sensor manual  2CDR
Mirror Download [FCC.gov]Aeon Labs DSB54-ZWUS RECESSED DOOR SENSOR User Manual Recessed Door Sensor manual  2CDR
Document ID1978722
Application IDsjN8LUp39Nm2f3Sv3mn6vw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.47kB (205928 bits)
Date Submitted2013-05-30 00:00:00
Date Available2013-05-30 00:00:00
Creation Date2013-01-25 06:21:24
Producing SoftwareCorel PDF Engine Version 3.0.0.667
Document Lastmod0000-00-00 00:00:00
Document TitleRecessed Door Sensor manual.-2CDR.cdr
Document CreatorCorelDRAW
Document Author: Administrator

Step 2
Quick Start
Drill a corresponding hole in your door. The hole should be
15 mm deep. As stated, the position of this hole should align
exactly with the one hole you just created in the doorframe.
Again, use a 19mm wide drill bit.
The installation of your Recessed Door Sensor has two
major steps: the installation of the Main Sensor and the
installation of the Magnetic Sensor. Powered by
batteries, your door sensor will use wireless technology
to talk to your Z-Wave network once installed.
15mm deep
Prepare the Main Sensor
19mm
The first step in installing your Recessed Door Sensor is
to activate the Main Sensor.
Recessed Door Sensor
1. Using a slot-head screwdriver, remove the Main
Sensor's lid by pressing gently against its exposed
connector.
View the expanded manual:
http://aeot.ec/spprt/recessed
Note: Ensure that the Main Sensor's button aligns with
the button hole of its lid.
Install your Recessed Door Sensor
With the Main Sensor powered and activated, it is now
time to inlay it within your selected doorframe and to also
install the Magnetic Sensor.
Drill bit
Door
With your door and doorframe prepared and the drill holes
created, it's now time to mount both parts of your Recessed
Door Sensor.
Step 3
Insert the Main Sensor into the hole you created in the
doorframe then secure it using two screws.
Before beginning it is important to select a suitable
position for your Recessed Door Sensor. For the following
instructions, your Recessed Door Sensor should be:
Installed at the top of a door or the side of door.
2. Separate the Main Sensor's two sections by first
removing its lid and then removing its internal
components.
Aeotec Recessed Door Sensor
Installed in a suitable location to ensure a clear(at
least 1mm) separation when the door is closed.
From Aeotec by Aeon Labs' Intelligence series comes
the Recessed Door Sensor. Invisibly installed, it sits
within a door and its frame to provide all the
information needed by a Z-Wave system for security,
safety, and ambiance, and it does it all without altering
a room's aesthetics.
Positioned away from metal that could interfere with
its magnetic functionality. This includes your door's
plate, handle or lock mechanism.
Positioned exactly above or beside the hole you'll later
in your door for the installation of the Magnetic Sensor.
Top of the door
Familiarise yourself with your door sensor
Side of the door
Secure with screws
Done
Step 4
Place a small amount of white glue (PVA) inside the hole
you created for the Magnetic Sensor. Then place the sensor
over and into the hole, and insert it by tapping gently on it
with a rubber hammer.
Your Recessed Door Sensor is comprised of two parts:
the larger Main Sensor and the smaller Magnetic
Sensor.
3. Remove the clear battery insulator by pulling it away
The larger Main Sensor
from the Main Sensor.
LED
Screw Hole
The rectangular areas highlighted above are the most
appropriate installation positions.
Screw Hole
Tap with hammer
Done
Step 1
Prepare a space for the Main Sensor by drilling a hole
into your doorframe using a 19mm wide drill bit. The
hole should be 65 mm deep.
Main Sensor
Z-Wave Button Hole
The Magnetic Sensor
65mm deep
19mm
Step 5
The gap between the two parts of your sensor must be
at least 1mm. If they are not, re-affix the Main Sensor
potentially by altering its hole.
Magnetic
Sensor
1mm
Main Sensor
Magnetic Sensor
A magnet in the plastic shell
4. With the battery insulator removed, reinsert the
internal components into the Main Sensor's enclosure
before reattaching its lid. The Main Sensor will now
look as it did prior to step 1.
Magnetic
Sensor
Doorframe
Drill bit
Main Sensor
4
Add your sensor to your Z-Wave network
Removing your sensor from your Z-Wave network
With your Recessed Door Sensor installed within a
door and its frame, it's time to add it to your Z-Wave
network. The following instructions tell you how to do
this using Aeotec's Z-Stick and Minimote controllers. If
you are using other products as your main Z-Wave
controller, please refer to the part of their respective
manuals that tells you how to add new devices to your
network.
Your sensor can be removed from your Z-Wave network
at any time. You’ll need to use your Z-Wave network’s
main controller to do this. The following instructions tell
you how to do this using Aeotec by Aeon Labs’ Z-Stick
and Minimote controllers. If you are using other products
as your main Z-Wave controller, please refer to the part
of their respective manuals that tells you how to remove
devices from your network.
If you are using a Z-Stick:
If you’re using a Z-Stick:
1. If your Z-Stick is plugged into a gateway or a
computer, unplug it.
2. Take your Z-Stick to your Recessed Door Sensor. Hold
the Action Button on your Z-Stick for 3 seconds.
3. Press the Z-Wave Button on your Main Sensor with a
small pin or toothpick.
4. If your Recessed Door Sensor had been successfully
removed from your network, the LED light will turn off.
If the removal was unsuccessful, the LED light will be
remain illuminate.
5. Press the Action Button on your Z-Stick to take it out of
removal mode.
1. If your Z-Stick is plugged into a gateway or a
computer, unplug it.
2. Take your Z-Stick to the door in which your
Recessed Door Sensor has been installed.
3. Press the Action Button on your Z-Stick.
4. Press the Z-Wave Button on your Main Sensor with
a small pin or toothpick.
5. I f y o u r R e c e s s e d D o o r S e n s o r h a d b e e n
successfully linked to your network, the LED light
will be blinking for a few seconds. If the linking was
unsuccessful, the LED light will be blinking for 8
seconds before turning off.
6. Press the Action Button on the Z-Stick to take it out
of installation mode.
If you’re using a Minimote:
1. Take your Minimote to your Recessed Door Sensor.
2. Press the Remove button on your Minimote.
3. Press the Z-Wave Button on your Recessed Door Sensor
with a small pin or toothpick.
4. If your Recessed Door Sensor had been successfully
removed from your network, the LED light will turn off.
If the removal was unsuccessful, the LED light will
remain illuminate.
5. Press any button on your Minimote to take it out of
removal mode.
Action Button
Remove
Any repairs under this warranty must be conducted by an
authorized Aeon Labs service representative and under
Aeon Labs' RMA policy. Any repairs conducted by
unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to
accidents, acts of God, civil or military authority, civil
disturbance, war, strikes, fires, other catastrophes,
misuse, misapplication, storage damage, negligence,
electrical power problems, or modification to the
Products or its components.
Aeon Labs does not authorize any person or party to
assume or create for it any other obligation or liability in
connection with the Products except as set forth herein.
Aeon Labs will pass on to Customer all manufacturers'
Material warranties to the extent that they are
transferable, but will not independently warrant any
Material.
Customer must prepay shipping and transportation
charges for returned Products, and insure the shipment
or accept the risk of loss or damage during such shipment
and transportation. Aeon Labs will ship the repaired or
replacement products to Customer freight prepaid.
Customer shall indemnify, defend, and hold Aeon Labs
and Aeon Labs' affiliates, shareholders, directors,
officers, employees, contractors, agents and other
representatives harmless from all demands, claims,
actions, causes of action, proceedings, suits,
assessments, losses, damages, liabilities, settlements,
judgments, fines, penalties, interest, costs and expenses
(including fees and disbursements of counsel) of every
kind (i) based upon personal injury or death or injury to
property to the extent any of the foregoing is proximately
caused either by a defective product (including strict
liability in tort) or by the negligent or willful acts or
omissions of Customer or its officers, employees,
subcontractors or agents, and/or (ii) arising from or
relating to any actual or alleged infringement or
misappropriation of any patent, trademark, mask work,
copyright, trade secret or any actual or alleged violation
of any other intellectual property rights arising from or in
connection with the products, except to the extent that
such infringement exists as a result of Aeon Labs'
manufacturing processes.
FCC NOTICE(for USA)
THE MANUFACTURER IS NOT RESPONSIBLE FOR
ANY RADIO OR TV INTERFERENCE CAUSED BY
U N A U T H O R I Z E D M O D I F I C AT I O N S T O T H I S
EQUIPMENT. SUCH MODIFICATIONS COULD VOID
T H E U S E R ' S A U T H O R I T Y T O O P E R AT E T H E
EQUIPMENT.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired
operation. This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
Consul the dealer or an experienced radio/TV
technician for help.
Warning
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information regarding
the collection systems available.
Certifications (regional):
Technical Sepcifications
Operating distance: Up to 100 feet / 30 meters indoors
and 300 feet / 100 meters outdoors.
Battery: lithium cell CR2, 3 volt battery, 800mAh.
Operating temperature: -10℃ to 60℃.
Relative humidity: 8%~80%.
If you are using a Minimote:
1. Take your Minimote to the door in which your
Recessed Door Sensor has been installed.
2. Press the Include button on your Minimote.
3. Press the Z-Wave Button on your Main Sensor with
a small pin or toothpick.
your Recessed Door Sensor had been
successfully linked to your network, the LED light
will be blinking for a few moments. If the linking was
unsuccessful, the LED light will be blinking for 8
seconds before turning off.
5. Press any button on your Minimote to take it out of
installation mode.
4. I f
Include
Warranty
Aeon Labs warrants to the original purchaser of Products
that for the Warranty Period (as defined below), the
Products will be free from material defects in materials
and workmanship. The foregoing warranty is subject to
the proper installation, operation and maintenance of the
Products in accordance with installation instructions and
the operating manual supplied to Customer. Warranty
claims must be made by Customer in writing within thirty
(30) days of the manifestation of a problem. Aeon Labs'
sole obligation under the foregoing warranty is, at Aeon
Labs' option, to repair, replace or correct any such defect
that was present at the time of delivery, or to remove the
Products and to refund the purchase price to Customer.
The "Warranty Period" begins on the date the Products is
delivered and continues for 12 months.
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY
INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE INCURRED BY
CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN
ACTION IN CONTRACT, OR TORT, OR OTHERWISE
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. AEON LABS' LIABILITY AND CUSTOMER'S
EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION
ARISING IN CONNECTION WITH THIS AGREEMENT
OR THE SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH
OF WAR R AN TY, BR EAC H OF AGR EEMEN T, OR
EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED TO,
AT AEON LABS' OPTION, REPLACEMENT OF, OR
REPAYMENT OF THE PURCHASE PRICE FOR THAT
PORTION OF PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND
ARISING IN CONNECTION WITH THIS AGREEMENT
OR THE SALE OR USE OF PRODUCTS SHALL BE
DEEMED WAIVED UNLESS MADE IN WRITING WITHIN
THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR
THE DATE FIXED FOR DELIVERY IN THE EVENT OF
NONDELIVERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES
OR WARRANTIES, WHETHER EXPRESS OR IMPLIED,
INCLUDING THE IMPLIED WARRANTIES OF
M E R C H A N TA B I L I T Y A N D F I T N E S S F O R A
PARTICULAR PURPOSE.
Version:501005400001-AA
www.aeotec.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
XMP Toolkit                     : 3.1-701
Creation Date--Text             : 
Producer                        : Corel PDF Engine Version 3.0.0.667
Mod Date--Text                  : 
Format                          : application/pdf
Creator                         : Administrator
Title                           : Recessed Door Sensor manual.-2CDR.cdr
Creator Tool                    : CorelDRAW
Modify Date                     : 2013:05:20 17:14:20+08:00
Metadata Date                   : 2013:05:20 17:14:20+08:00
Document ID                     : uuid:acf3146b-c868-4204-8a18-d9da6953de6c
Instance ID                     : uuid:87af8ea9-dfdd-4b19-b4d5-50240bce52b9
Page Count                      : 2
Create Date                     : D:20130125062124
Author                          : Administrator
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBADSB54-ZWUS

Navigation menu