Airspan Networks H4K425 Base station of LTE fixed cellular system User Manual AirHarmony 4400 ext Installation Guide
Airspan Networks Inc Base station of LTE fixed cellular system AirHarmony 4400 ext Installation Guide
Users Manual
AirHarmony-4400 Installation Guide External Cavity Filters Part Number: UGD-D01186 System Release: 15.0 Revision: A Published: December 2016 © Copyright by Airspan Networks Ltd., 2016-2016. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary, privileged and intended only for the recipient. As such, the information is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Ltd. rights in the aforesaid information. Neither this document nor the information contained herein may be published, reproduced, transmitted or disclosed to third parties, in whole or in part, without the express, prior, written permission of Airspan Networks Ltd. In addition, any use of this document or the information contained herein for the purposes other than those for which it is disclosed is strictly forbidden. Airspan Networks Ltd. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by Airspan Networks Ltd. is believed in good faith to be accurate and reliable, while every care has been taken in preparing these documents. However, Airspan Networks Ltd. does not make any representations and gives no warranties of whatever nature in respect of these documents, including without limitation, the accuracy or completeness of any information, facts and/or opinions contained therein. No responsibility is assumed by Airspan Networks Ltd. for the use of the documents nor for the rights of third parties which may be effected in any way by the use thereof. The provision of these documents (and the documents themselves) does not constitute professional advice of any kind. Any representation(s) in these documents concerning performance of Airspan Networks Ltd. product(s) are for informational purposes only and are not warranties of future performance, either expressed or implied. Airspan Networks Ltd., its affiliates, directors, employees and agents shall not be held liable for any damages or losses, of any nature whatsoever, arising from any use of and/or reliance on the documents. These documents may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in relation thereto unless specifically undertaken in Airspan Networks Ltd. sales contract or order confirmation. Information contained herein is periodically updated and changes will be incorporated into subsequent editions. If you have encountered an error, please notify Airspan Networks Ltd. Product performance figures quoted within this document are indicative and for information purposes only. UK WEEE Registration number: WEEE/AB0207WZ. For more information, see WEEE Information for Airspan Customers and Recyclers. Acknowledgements © Intel Corporation http://www.intel.com/ © Microsoft Corporation http://www.microsoft.com Table of Contents Document Information ...................................................................................... 2 Abstract ................................................................................................................................. 2 Revision History ..................................................................................................................... 2 Warnings and Cautions ...................................................................................... 3 Human Exposure to Radio Frequencies ................................................................................ 3 Radio Interference ................................................................................................................ 3 Modifications ........................................................................................................................ 3 General .................................................................................................................................. 3 Général .................................................................................................................................. 3 Important Safety Instructions ......................................................................................... 4 Safety..................................................................................................................................... 4 Securite.................................................................................................................................. 5 Warning of Hazardous Voltages ............................................................................................ 5 Attention aux Voltages Hasardeux........................................................................................ 5 Adherence to European Directive 1999/5/EC....................................................................... 6 Warning Symbols .................................................................................................................. 6 Service Information ............................................................................................................... 6 UL Information ...................................................................................................................... 7 Lightning Protection .............................................................................................................. 7 Outdoor Ethernet Cabling ..................................................................................................... 8 DECLARATION OF CONFORMITY ........................................................................................... 8 GPS Compliance .................................................................................................................... 9 Maximum Output TX Total Power...................................................................... 9 Power Consumption ............................................................................................................ 10 Antenna System .................................................................................................................. 10 Long Switched Beam Antenna ............................................................................................ 10 External Antenna ................................................................................................................. 11 UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide About This Document ...................................................................................... 12 Purpose ............................................................................................................................... 12 Intended Audience .............................................................................................................. 12 Document Conventions....................................................................................................... 12 Document Organization ...................................................................................................... 13 Related Reading .................................................................................................................. 13 Customer Care Help Desk ................................................................................ 14 Airspan Encourages Comments .......................................................................................... 14 1 Introduction ................................................................................................. 15 1.1 AirHarmony-4400 ........................................................................................................ 15 1.2 Deployment ................................................................................................................. 15 2 Getting Started ............................................................................................ 17 2.1 Workflow of Installation .............................................................................................. 17 2.2 AirHarmony-4400 Installation Checklist ...................................................................... 18 3 Verifying Prerequisites ................................................................................. 18 3.1 Verifying Site Requirements ........................................................................................ 18 3.2 Verify Installation Requirements ................................................................................. 18 3.2.1 Verify the Tools ........................................................................................................... 18 3.2.2 Verify the Parts and Kits .............................................................................................. 19 3.2.3 Power Supply and Current .......................................................................................... 21 3.2.4 Panels .......................................................................................................................... 22 3.2.5 Physical Dimensions .................................................................................................... 23 3.2.6 Environmental ............................................................................................................. 24 4 Installing AirHarmony-4400 ......................................................................... 25 4.1 Rear External Filter Set Assembly ................................................................................ 25 4.2 Front External Filter Set Assembly .............................................................................. 28 4.3 Connecting the GPS Antenna ...................................................................................... 33 4.4 Pole/Wall Mount Assembly ......................................................................................... 35 4.4.1 Mounting on a Wooden Pole ...................................................................................... 35 UGD-D01186 Airspan Commercial and Internal Use ii AirHarmony-4400 (External Cavity Filters) Installation Guide 4.4.2 Mounting on a Non-Wooden Pole .............................................................................. 37 4.4.3 Mounting on a Wall ..................................................................................................... 38 4.5 Securing AirHarmony-4400 to the Mounting Plate ..................................................... 40 5 AirHarmony-4400 Connections .................................................................... 44 5.1 Grounding .................................................................................................................... 44 5.2 Remote Antenna Assembly ......................................................................................... 44 5.2.1 Connecting RF Jumper Cables to External Antenna .................................................... 44 5.2.2 Weather-proofing the Antenna Connections ............................................................. 45 5.3 Cable Connections ....................................................................................................... 46 5.3.1 Copper Ethernet Cable Assembly ................................................................................ 46 Assembly Instructions............................................................................................................. 46 5.4 Fiber Ethernet (SFP) Cable Installation ........................................................................ 47 5.4.1 SFP Cable Connection.................................................................................................. 47 5.5 Connecting the AC Power Cable to AirHarmony-4400................................................ 49 5.5.1 Power Cable Preparation ............................................................................................ 49 5.5.2 Securing Connector Clamp .......................................................................................... 53 A Job Sheet ..................................................................................................... 54 B Abbreviations............................................................................................... 55 Figures Figure 1: AirHarmony-4400 with external cavity filters & cover .......................................................... 11 Figure 2: AirHarmony-4400 with Front & Rear Filter Sets & cover ...................................................... 16 Figure 3: Workflow................................................................................................................................ 17 Figure 4: AirHarmony-4400 Unit, Bottom panel ................................................................................... 22 Figure 5: AirHarmony-4400 Unit, Top panel ......................................................................................... 23 Figure 6: AIrHarmony-4400 - in Horizontal Position prior to Rear External Filters Set Assembly ........ 25 Figure 7: Rear External Filters' Set ........................................................................................................ 26 Figure 8: Mounting Rear External Filters' set ....................................................................................... 26 Figure 9: Back Bracket Assembly .......................................................................................................... 27 Figure 10: Fitting RF Connector ............................................................................................................ 27 Figure 11. Tighten the Filter Screws ..................................................................................................... 27 Figure 12: Tighten Hex Head Bolts ........................................................................................................ 28 Figure 13: AIrHarmony-4400 in Prone Position Prior to Front External Filter Assembly...................... 28 Figure 14: External Filters' Set .............................................................................................................. 29 UGD-D01186 Airspan Commercial and Internal Use iii AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 15: External Filters' Set slots & fastenings ................................................................................. 29 Figure 16: Mounting External Filters' set on Sun-shield ....................................................................... 30 Figure 17: Opening cover ...................................................................................................................... 30 Figure 18. Cover opened ....................................................................................................................... 31 Figure 19: Align and fit filter to connector............................................................................................ 31 Figure 20: Tighten screws on filter........................................................................................................ 32 Figure 21: Align and fit second filter to connector ............................................................................... 32 Figure 22: Tighten filter bridge screws on Sun-Shield .......................................................................... 33 Figure 23: Tighten screws on cover ...................................................................................................... 33 Figure 24: Attaching GPS antenna to unit............................................................................................. 34 Figure 25: Pole/Wall mounting plate .................................................................................................... 35 Figure 26: Mounting plate on pole ....................................................................................................... 36 Figure 27: Through-bolt & Mounting plate........................................................................................... 37 Figure 28: Pole/Wall mounting plate (w/o bolt) ................................................................................... 37 Figure 29: Mounting plate mounted..................................................................................................... 38 Figure 30: Mounting Plate on Wall ....................................................................................................... 39 Figure 31: Lift unit and fit the slotted holes unto studs on top of mounting plate .............................. 40 Figure 32: Align Pins .............................................................................................................................. 41 Figure 33: AirHarmony mounted on Wooden Pole .............................................................................. 41 Figure 34: AirHarmony mounted on Concrete Pole ............................................................................. 42 Figure 35: AirHarmony being mounted on a Wall ................................................................................ 43 Figure 36: Grounding ............................................................................................................................ 44 Figure 37: DIN 4.1/9.5 connectors (external thread)............................................................................ 45 Figure 38: Gland connector - copper .................................................................................................... 46 Figure 39: Ethernet Cable through connector ...................................................................................... 46 Figure 40: LC duplex cable assembly .................................................................................................... 47 Figure 41: Cable connector hook up to the board connector .............................................................. 47 Figure 42: Slide on inner housing.......................................................................................................... 48 Figure 43: Slide over and click............................................................................................................... 49 Figure 44: AC connector........................................................................................................................ 49 Figure 45: AC Connector disassembled ................................................................................................ 50 Figure 46: Strip wire .............................................................................................................................. 50 Figure 47: power cable assembly.......................................................................................................... 50 Figure 48: Connector on cable .............................................................................................................. 50 Figure 49: Plug pins ............................................................................................................................... 51 Figure 50: Pin assignment ..................................................................................................................... 51 Figure 51: Attaching wires .................................................................................................................... 51 Figure 52: Connector Clamp ................................................................................................................. 52 Figure 53: Power cable attached to AirHarmony-4400 ........................................................................ 52 Figure 54: Securing the connection ...................................................................................................... 53 Tables Table 1: AirHarmony-4400DF B41 Full Band FCC Maximum Output TX Total Power............................. 9 Table 2: AirHarmony-4400DH B41 High Band FCC Maximum Output TX Total Power .......................... 9 Table 3: AirHarmony-4400DL B41 Low Band FCC Maximum Output TX Total Power .......................... 10 Table 4: AirHarmony-4400 ETSI Maximum Output TX Total Power ..................................................... 10 Table 5: Power Consumption ................................................................................................................ 10 UGD-D01186 Airspan Commercial and Internal Use iv AirHarmony-4400 (External Cavity Filters) Installation Guide Table 6: Typographic Conventions ........................................................................................................ 12 Table 7. Minimum Hardware Requirements ........................................................................................ 18 Table 8. Parts & Kits .............................................................................................................................. 19 Table 9. Amperage Draw....................................................................................................................... 22 Table 10: AirHarmony-4400 Physical Dimensions ................................................................................ 23 Table 11: AirHarmony-4400 Environment Compliance ........................................................................ 24 Table 12: Job Sheet ............................................................................................................................... 54 UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide Document Information Abstract This document details procedures for installing the Airspan’s AirHarmony-4400 EXT, a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for qualified personnel with a working knowledge of LTE. Revision History Revision Details Date Rev 0.1 November 2016 Initial document – draft Comments Rev A December 2016 Publish UGD-D01186 Summary of Changes Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide Warnings and Cautions Human Exposure to Radio Frequencies The AirHarmony-4400 antennas should be operated from a minimum safe distance of 4.6m Radio Interference The AirHarmony generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the technician is encouraged to try to correct the interference by performing one or more of the following measures: Re-orientate or relocate the unit Increase separation between the units and/or End Devices Connect the equipment to a circuit different from that to which the power source is connected Modifications Any changes and modifications to this device that are not expressly approved by Airspan Networks may void the user's authority to operate the equipment. General Only qualified personnel should be allowed to install, replace, and service the equipment. The device cannot be sold retail, to the general public or by mail order. It must be sold to operators. Installation must be controlled. Installation must be performed by licensed professionals. Installation requires special training. The AirHarmony-4400 should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void Airspan's product warranty and may expose the end user or the service provider to legal and financial liabilities. Airspan and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas. The device is to be installed in a Restricted Access Location. Surge Arrestors and Transient Voltage Surge Suppressors installed external to the ITE are required to comply with the appropriate CEC/NEC requirements. Général Seul le personnel qualifié peut être autorisé pour installer ou remplacer l’équipement ainsi qu’effectuer les opérations de maintenance pour cet équipement. L’équipement ne peut pas être vendu en grande distribution ou par commande via email à destination du public. Il doit être vendu aux opérateurs de télécommunications. Son installation doit être contrôlée. Son Installation doit être effectuée par des professionnels autorises. UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide Son installation requiert une formation spécifique du personnel. L’AirHarmony-4400, radio et antenne doit être installe UNIQUEMENT par des installateurs professionnels expérimentés et ayant une connaissance des constructions locales et règles de sécurité, ainsi que, dès que nécessaire, disposant d’un agreement des autorités gouvernementales de régulation. Toute enfreinte a ces obligations peut annuler la garantie délivrée par Airspan pour ces produits et peut exposer l’utilisateur final ou le fournisseur de services a des dommages légaux et financiers. Airspan et ses revendeurs ou ses distributeurs ne sont pas responsables des blessures, dommages ou violations de la régulation en vigueur lies a l’installation du système extérieur ou des antennes. L’Equipment doit être installe dans une zone a accès réduit et contrôle. Parafoudres et Protections contre les surtensions transitoires doivent etre installés a l’exterieur de l’équipement ITE sont tenus de se conformer aux exigences relatives aux normes CEC/NEC concernées Important Safety Instructions Read and Save these instructions This Installation Guide contains instructions and warnings that should be followed during installation, and operation. Failure to follow these instructions could cause bodily injury and/or product failure Safety 1. Read this guide and follow all operating and safety instructions. 2. Static sensitive components inside - do not remove the lid or base: No user serviceable parts inside. 3. The ground connection should be made before connecting to supply connections. 4. Position the power cord to avoid possible damage; do not overload circuits. 5. Do not place this product on or near a direct heat source, and avoid placing objects on the terminal. 6. To avoid electrical shock do not install this device during adverse conditions such as rain or inclement weather. 7. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the power before cleaning. 8. The units should not be located too near power lines or other electrical power circuits, where it can come into contact with such power lines or circuits. 9. The radio transceiver must be properly grounded to protect against power surges and accumulated static electricity. It is the user’s responsibility to install this device in accordance with the local electrical codes. 10. Installation of the AirHarmony-4400 must be contracted to a professional installer. 11. The circuit breaker should be easily accessible in case you have to disconnect the device. 12. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide Securite 1. Lire attentivement ce guide et suivre les instructions d’utilisation et de sécurité. 2. Des composants sensibles a électricité statique sont utilisés à l’intérieur. Ne pas retirer le coffre ou la base. Aucune pièce a l’intérieur est d’utilité pour l’utilisateur. 3. La connexion "terre" doit être effectuée en priorité et avant d'effectuer les connexions à la source d'alimentation (phase et neutre). 4. Positionner le cordon d’alimentation de façon à éviter des dommages potentiels. Ne pas surcharger les circuits. 5. Ne pas placer ce produit sur ou à proximité d’une source directe de chaleur et éviter de placer des objets sur le terminal. 6. Afin d’éviter des problèmes électriques, ne pas installer cet équipement au cours d’évènements climatiques difficiles comme averses ou météo non clémente. 7. Utiliser uniquement chiffon de coton pour nettoyage. Ne pas utiliser de produits liquides ou d’aérosols. Déconnecter le produit de la source d’alimentation avant nettoyage. 8. L’unité ne doit pas être située trop près de lignes électriques ou autres circuits de puissance, avec lesquels il pourrait entrer en contact. 9. L’émetteur radio doit être correctement relie a la terre afin de le protéger contre les surtensions ou accumulation d’électricité statique. L’utilisateur est tenu responsable de l’installation du produit conformément aux règles électrique en vigueur localement. 10. L’installation de AirHarmony-4400 doit être contractualisée avec un installateur professionnel. 11. L’interrupteur de circuit électrique doit être facilement accessible afin de pouvoir déconnecter l’équipement. 12. Lors de l’installation de la configuration finale, le produit doit être conforme aux Standards de Sécurité en vigueur ainsi qu’aux exigences réglementaires du pays dans lequel il est installé. Si nécessaire, consulter les agences règlementaires appropriées, ainsi que les autorités chargées de l’inspection afin de garantir la conformité. Warning of Hazardous Voltages On AC installations, hazardous voltages exist. Use caution when verifying or working with AC power. Remove metal jewelry that could come into contact with AC power. On DC sections, short-circuiting the low voltage, low impedance circuits can cause severe arcing that may result in burns or eye damage. Remove rings, watches etc. to avoid shorting DC circuits. Note: Airspan products do not contain hazardous substances (as defined in UK Control of Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements. Attention aux Voltages Hasardeux Sur les installations de réseau électrique de type courant alternatif (CA), des voltages hasardeux peuvent survenir. Garder une Attention particulière lors d’une vérification ou de travaux sur réseau électrique CA. Retirer tous bijoux en métal qui pourraient entrer en contact avec l’alimentation ou le réseau CA. UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide Sur les portions de réseau électrique de type courant continu (CC), un circuit basse impédance peut causer de sérieux arcs électriques qui pourraient bruler ou endommager les yeux. Retirer bagues, anneaux, montres etc… afin d’éviter les court-circuit sur le réseau CC. Adherence to European Directive 1999/5/EC European Council Recommendation 1999/5/EC details basic restrictions and reference levels on human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these recommended restrictions and reference levels should provide a high level of protection as regards the established health effects that may result from exposure to electromagnetic fields. Airspan equipment is compliant with CE and R&TTE regulations and can be operated in all EU (European Union) locations listed below: Country Code BE EL LT PT BG ES LU RO CZ FR HU SI DK HR MT SK DE IT NL FI EE CY AT SE IE LV PL UK Warning Symbols The following symbols may be encountered during installation or troubleshooting. These warning symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters. Familiarize yourself with standard safety practices before continuing. Caution, hot surface Caution Electro-Magnetic Radiation High Voltage Service Information Refer all repairs to qualified service personnel. Do not modify any part of this device, as this will void the warranty. Disconnect the power to this product and return it for service if the following conditions apply: UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide a. The terminal does not function after following the operating instructions outlined in this manual. b. The product has been dropped or the housing is damaged. Locate the serial number of the terminal and record this on your registration card for future reference. Also record the MAC address, located on the product sticker. UL Information - The equipment must be properly grounded according with NEC and other local safety code requirements. - Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as is practical. - AirHarmony-4400 is designed to operate in environmental conditions complying with IP66 and relevant standards. Lightning Protection WARNING: The following notes are general recommendations for the system. The wireless equipment should be installed by a qualified professional installer and must follow local and national codes for electrical grounding and safety. Failure to meet safety requirements and/or use of nonstandard practices and procedures could result in personal injury and damage to equipment. A direct lightning strike may cause serious damage even if these guidelines are followed. All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced current from a near strike. Lightning protection and grounding practices in local and national electrical codes serve to minimize equipment damage, service outages, and serious injury. Reasons for lightning damage are summarized as: - Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment. - Lack of properly installed lightning protection equipment that can cause equipment failures from lightning induced currents. A lighting protection system provides a means by which the energy may enter earth without passing through and damaging parts of a structure. A lightning protection system does not prevent lightning from striking; it provides a means for controlling it and preventing damage by providing a low resistance path for the discharge of energy to travel safely to ground. Improperly grounded connections are also a source of noise that can cause sensitive equipment to malfunction. A good tower grounding system disperses most of the surge energy from a tower strike away from the building and equipment. To limit the equipment damage due to a lightning strike, the following practices are recommended for the wireless system: - Provide direct grounding from the antenna mounting bracket, the radio and antenna and the lightning/surge protectors to the same ground point at the base of the tower or a ground bus on the building. Use the grounding screws on the antenna bracket and the radio and antenna for terminating the ground wires. UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide - The AC wall outlet ground must be connected to the same grounding system as the eNodeB. Outdoor Ethernet Cabling - Ethernet cable connected to should be outdoor grade with UV protection. - Use shielded out CAT5e (minimum) cabled terminated with metallic RJ45 connectors. - In order to protect the indoor unit, install surge protection circuits on all copper cables on their entrance to the building. - Surge protection circuit must use a minimum 16AWG grounding cable. DECLARATION OF CONFORMITY European Community, Switzerland, Norway, Iceland, and Liechtenstein Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC English: This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Deutsch: Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie 1999/5/EU. Dansk: Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF. Español: Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC. Greek: ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ. Français: Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC. Íslenska: Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB. Italiano: Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC. Nederlands: Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC. Norsk: Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC. Português: Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC. UGD-D01186 Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide Suomalainen: Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen. Svenska: Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC. Român: Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei 1999/5/CE. The Declaration of Conformity related to this product can be obtained from PLM@Airspan.com. GPS Compliance The GPS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC." The GPS complies with the following EMC Common Regulatory Testing standards: EN55022: Radiated and Conducted Emissions CISPR 22: Class B EN 50081-1: Generic Emissions Class B EN 50082-1: Generic Immunity Class B EN 61000-4-2: Electrostatic Discharge Immunity EN 61000-4-3: Radiated RF EM Field Immunity Test EN 61000-4-4: Electrical Fast Transient/Burst Test EN 61000-4-6: Conducted Immunity EN 61000-4-8: Magnetic Field Immunity Note: A GPS is recommended for synchronizing between LTE sectors. Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS antenna in a remote location for lightning prone deployments. Maximum Output TX Total Power Table 1: AirHarmony-4400DF B41 Full Band FCC Maximum Output TX Total Power Frequency Band 2496 – 2690 MHz FCC TX Antenna Gain EIRP 46.20 dBm 64.20 dBm 18dBi Table 2: AirHarmony-4400DH B41 High Band FCC Maximum Output TX Total Power Frequency Band 2618 – 2690 MHz UGD-D01186 FCC TX Antenna Gain EIRP 46.20 dBm 64.20 dBm 18dBi Airspan Commercial and Internal Use AirHarmony-4400 (External Cavity Filters) Installation Guide Table 3: AirHarmony-4400DL B41 Low Band FCC Maximum Output TX Total Power Frequency Band 2496 – 2568 MHz FCC TX Antenna Gain EIRP 46.20 dBm 64.20 dBm 18dBi Table 4: AirHarmony-4400 ETSI Maximum Output TX Total Power Frequency Band 2496 – 2690 MHz ETSI TX Antenna Gain EIRP 46 dBm 64 dBm 18dBi Caution: Do not set maximum output TX power to higher than local regulations. Power Consumption AirHarmony-4400 power consumption is described in the following table: Table 5: Power Consumption Duplex Tx Power at RF Port (dBm) Nominal Power Consumption (W) TDD- FC1 2 x 43 265 FDD 2 x 43 340 Antenna System AirHarmony-4400 comes in a range of frequency variants that can be mounted with different antenna options and formats. A typical installation will have a cross-polar sector or dual slant antenna connected to the approprate Cavity filter of the AirHarmony-4400 variant unit. Various antennas are designed specifically for AirHarmony-4400 deployments; specifications are available from Airspan separately. Long Switched Beam Antenna Long Switched Beam antenna variant includes a steerable antenna mounted on the unit with the following specification. The antenna is a multi-element cross polarized (dual slant) design which can be used in directional or Omni modes of operation. Scenario #1 - The long switched beam antenna is mounted directly on the unit and connected via its two RF ports and the control port. The GPS antenna is either mounted on the top of the unit (if conditions allow) or mounted separately with approved lightning protection. Scenario #2 - The long switched beam antenna is mounted on the pole above the unit connected via its two RF ports and the control port. UGD-D01186 Airspan Commercial and Internal Use 10 AirHarmony-4400 (External Cavity Filters) Installation Guide External Antenna The externally mounted antenna should be a dual slant or cross polarized fixed antenna which are connected via two (2) DIN connectors located on the top panel or to the external Cavity filter. The antenna should be mounted to its appropriate mounting facility. Note: When utilized in conjunction with iRelay as backhaul maintain a vertical separation of at least 2 ft. (0.6 m). Figure 1: AirHarmony-4400 with external cavity filters & cover UGD-D01186 Airspan Commercial and Internal Use 11 AirHarmony-4400 (External Cavity Filters) Installation Guide About This Document Purpose This guide provides the workflow and step-by-step procedures for installing the Airspan’s AirHarmony-4400 Macro-class eNodeB variant. These procedures include: Verify prerequisites Assemble Front Filter set Assemble Rear Filter set Mount GPS Install Mounting bracket Install the AirHarmony-4400 Mount Antenna (either LSBA or external antenna) Mount iRelay (if applicable) Connect to External Antenna (if applicable) Connect and manage cables Intended Audience This guide is intended for persons who are responsible for installing the AirHarmony-4400. These persons should have a working knowledge of the equipment. AirHarmony can be tightly integrated with Airspan’s iBridge and iRelay transport solutions. AirHarmony-4400 supports an integrated PoE interface which powers and connects either iBridge, iRelay, or a third party WiFi Access Point. This configuration creates a single piece installation that supports full end to end IPv6 plug and play deployment by just adding power. For more details please refer to the iBridge and iRelay product specifications. Document Conventions This document uses the following typographic conventions. Table 6: Typographic Conventions Convention Element Blue underlined text Cross-reference links. Bold text Keyboard buttons and GUI elements. Command Command names or phrases. Computer output Text displayed by the computer. Hyperlinks Website and e-mail addresses. Danger Signifies a hazardous situation—if not avoided—will cause death or serious injury. Describes how to avoid it. Warning Signifies a hazardous situation—if not avoided—can cause death or serious personal injury. Describes how to avoid it. UGD-D01186 Airspan Commercial and Internal Use 12 AirHarmony-4400 (External Cavity Filters) Installation Guide Convention Element Caution Signifies a hazardous situation—if not avoided—can void the product warranty, and cause property damage. Describes how to avoid it. Important Provides necessary information to explain a task. Note Provides additional information. Tip Provides helpful hints. Document Organization Chapter Contents Introduction Provides a comprehensive overview of AirHarmony-4400 and its installation. Getting Started Provides workflows for initial install and workflow. Verifying Prerequisites Lists the hardware, software, and client requirements for installation. AirHarmony-4400 Installation Describes how to install AirHarmony-4400. GPS Installation Describes how to install the GPS antenna. Connect and Manage Cables Describes how to connect the cables. Job Sheet Provides information that aids users in performing the installation. Abbreviations Lists the abbreviations used in this document and their expansions. Related Reading The following documents contain related information: AirHarmony-4400 Hardware Product Specification Airspan LTE Commissioning Manual UGD-D01186 Airspan Commercial and Internal Use 13 AirHarmony-4400 (External Cavity Filters) Installation Guide Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e-mails to Customer Care Help Desk. Once you submit your issue, the system generates a new issue and sends an issue number for your reference. The system uses this issue number to categorize and store e-mails under the appropriate issue. To help Customer Care Help Desk identify your issue, include the issue number and your Customer Care Helpdesk account details in all further communications. Main Operations Worldwide Headquarters Airspan Communications Ltd. Capital Point 33 Bath Road Slough, Berkshire SL1 3UF, United Kingdom Tel: +44-1895-467-100 Airspan Networks Inc. 777, Yamato Road, Suite 105 Boca Raton, FL 3341-4408, USA Tel: +1 561 893 8670 Airspan Encourages Comments Airspan welcomes any feedback and suggestions that help to improve the quality of the documentation. Send your feedback to documentfeedback@airspan.com. UGD-D01186 Airspan Commercial and Internal Use 14 AirHarmony-4400 (External Cavity Filters) Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirHarmony-4400 with external cavity filters a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for readers with LTE working knowledge. All information in this document is for general information only, and is subject for change without notice. 1.1 AirHarmony-4400 AirHarmony-4400 is part of Airspan’s carrier-class LTE Advanced small cell eNodeB family. AirHarmony-4400 is a Macro-class product that supports 3GPP’s Long Term Evolution (LTE) eNodeB specifications, providing high-speed data, mobility, Voice over LTE, and broadcast/multicast services in order to meet the demands of the LTE Mobile Carriers. AirHarmony-4400 is a compact, easy to install Macro-class eNodeB, allowing an operator to deploy LTE broadband services using existing infrastructure or Street Furniture (e.g. street lamps, power poles, building rooftop or sides etc…) AirHarmony-4400 employs Software Defined Radio (SDR) technology, together with two transmit and receive paths for each sector and a GPS antenna and receiver – all in a highly integrated, physically small and light, All-Outdoor package, targeted to blend seamlessly into the urban environment. This compact outdoor product minimizes physical footprint, power consumption and operator OPEX. AirHarmony-4400 is a 2T2R solution that enables a flexible deployment scenarios, but can achieve higher coverage and throughput by combing multiple eNodeBs enabling the support of 4T4R, 4T8R, and 8T8R. AirHarmony-4400 implements 2 x 20W transmitters (2 x 43 dBm) and fully supports the standard LTE (Uu/S1/X2) interfaces. All Airspan eNodeB products, including AirHarmony-4400, are interoperable with a rich portfolio of 3rd party end user devices, including many handsets, indoor UEs, outdoor UEs and USB dongles from several ODMs, using various chipsets. For an updated of interoperability list, please contact your nearest Airspan Sales Representative. Additionally, AirHarmony can be tightly integrated with Airspan’s iBridge and iRelay transport solutions. AirHarmony-4400 supports an integrated PoE interface which powers and connects either iBridge, iRelay, or a third party Wi-Fi Access Point. This configuration creates a single installation that fully supports end to end IPv6 plug and play deployment by just adding power. For more details please refer to the iBridge and iRelay product specifications. Note: For management please refer to the Airspan LTE Commissioning Manual as well as Netspan. 1.2 Deployment A highly flexible and scalable 4G Base Station, the AirHarmony-4400 is capable of supporting LTE profiles across multiple frequency bands. UGD-D01186 Airspan Commercial and Internal Use 15 AirHarmony-4400 (External Cavity Filters) Installation Guide Note: AirHarmony-4400 must be properly grounded (16AWG minimum) according with NEC and other local safety code requirements. Warning: Required - circuit breaker for AC power source -16A for EU installation and 20A for US installation. Minimum – 10A. Figure 2: AirHarmony-4400 with Front & Rear Filter Sets & cover Note: External Filters set are sold separately and are installed on site by the customer. UGD-D01186 Airspan Commercial and Internal Use 16 AirHarmony-4400 (External Cavity Filters) Installation Guide Getting Started 2.1 Workflow of Installation The Workflow to install the AirHarmony-4400 is displayed in the following diagram: Figure 3: Workflow Caution: Antennas and External filters must be connected and attached before AirHarmony-4400 is powered on. UGD-D01186 Airspan Commercial and Internal Use 17 AirHarmony-4400 (External Cavity Filters) Installation Guide 2.2 AirHarmony-4400 Installation Checklist Plan the installation of the AirHarmony-4400 by using the Installation Checklist, which you can find as a removable job aid in Appendix A for this guide. 3 Verifying Prerequisites Prior to installing the AirHarmony-4400, verify the required safety, power, tools, parts and components. This chapter includes the hardware, software, and client requirements for installation. Important: Set up requirements for the installation is detailed in the Job Sheet, see Appendix_A. 3.1 Verifying Site Requirements To set up the AirHarmony-4400, an IP connection to a Netspan server is required. 3.2 Verify Installation Requirements 3.2.1 Verify the Tools Table 7. Minimum Hardware Requirements Tool Use Medium Phillips head screw driver for securing the M5 Pan Head screws on Filter sets #13 wrench for securing the M8 Hex Head bolts on the Pole/wall mount For AC power cable preparation Small flat blade screw driver (insulated shaft recommended) pliers For AC power cable preparation Knife For AC cable preparation Small side cutters For AC power cable preparation Wire strippers For AC power cable preparation 1/2” Socket Wrench For 5/16” Hex head (Lag) bolts when wall mounting UGD-D01186 Airspan Commercial and Internal Use 18 AirHarmony-4400 (External Cavity Filters) Installation Guide 3.2.2 Verify the Parts and Kits Note: Verify your order and requirements to ensure the correct unit type is being installed. Table 8. Parts & Kits Installation Kit / Part AirHarmony 4400 2500M Hz (B41) Part No. Airspan N0. 998-43413SP Consisting of: AirHarmony 4400 universal wall & pole mounting kit HAR40U-PMK-1 903-03-257 Harmony440 0 External filters set B41 Low Band HAR44FLTR-KITU41L 903-03-264 Harmony440 0 External filters set B41 High Band HAR44FLTR-KITU41H 903-03-266 Harmony440 0 External filters set B41 Full Band HAR44FLTR-KITU41F 903-03-265 AirHarmony 4400 External filters set B41 Low Band U41-Low External IP67 Single Cavity Filter 24962568MHz, DIN 4.1/9.5(f) connectors X4 Filter set mounting with screws AirHarmony 4400 External filters set B41 High Band U41-High Single External IP67 Cavity Filter 26182690MHz, DIN(f)4.1/9.5 connectors X4 Filter set mounting with screws AirHarmony4400 External filters set B41 Full Band Filter,Cavity,24962690MHz,External,SMP connector X4 Filter set mounting with screws GPS Antenna GPS Antenna GPSANT-3 350-05-009 GPS Antenna with built-in high, interference rejection GPS Antenna Kit GPSHAR-KIT1 N/A AirHarmony GPS Kit (including antenna, bracket, 80cm cable and surge protection kit) HAR44EF-U41B06AP Image AirHarmony 4400 2.496 2.69 GHz (B41, B38), External Filters (not included), Connectorized 2x Fiber + 2x Copper, PoE, AC Pole/wall mount bracket Screws for connecting the unit External Filters Sets Or UGD-D01186 Airspan Commercial and Internal Use 19 AirHarmony-4400 (External Cavity Filters) Installation Guide Installation Kit / Part Part No. Airspan N0. Consisting of: Image LSBA Control Cable Long SBA control cable AISG to AISG 1.5m Long SBA control cable AISG to AISG 3m Long SBA control cable AISG to AISG 5m Long SBA control cable AISG to AISG 10m Long SBA control cable AISG to AISG 16m CBLSBALCTRL1.5-1 CBLSBALCTRL-3-1 680-00-191 CBLSBALCTRL-5-1 680-00-193 CBLSBALCTRL-101 CBLSBALCTRL-161 680-00-194 680-00-192 680-00-195 Full AXS SM Fiber Cable Full AXS SM Fiber Cable 5m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 7.5m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 15m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 30m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 50m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 75m, Outdoor LC/DPX to LC, IP67 UGD-D01186 FIB-FA-5LC-SM-1 686-00-016 FIB-FA7.5-LCSM-1 686-00-017 FIB-FA15-LCSM-1 686-00-015 FIB-FA30-LCSM-1 686-00-009 FIB-FA50-LCSM-1 686-00-010 FIB-FA75-LCSM-1 686-00-011 Airspan Commercial and Internal Use 20 AirHarmony-4400 (External Cavity Filters) Installation Guide Installation Kit / Part Full AXS SM Fiber Cable 100m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 150m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 200m, Outdoor LC/DPX to LC, IP67 Part No. FIB-FA100-LCSM-1 Airspan N0. 686-00-012 FIB-FA150-LCSM-1 686-00-013 FIB-FA200-LCSM-1 686-00-014 Consisting of: Image 3.2.3 Power Supply and Current AirHarmony-4400 supports direct connection to AC power source: Operational Voltage Range: 100VAC~240VAC, 47Hz~63Hz Warning: Power provided by PoE outputs (RJ45 ETH1, ETH2) cannot be considered limited power source (LPS) per IEC/UL 60950-1 clause 2.5 UGD-D01186 Airspan Commercial and Internal Use 21 AirHarmony-4400 (External Cavity Filters) Installation Guide Table 9. Amperage Draw Duplex Tx Power at RF Port (dBm) Maximum Power Consumption (W) TDD-FC1 2 x 43 340 FDD 2 x 43 340 3.2.4 Panels The following figures display the AirHarmony-4400 bottom and top panels. The following displays the AirHarmony-4400’s bottom panel. Figure 4: AirHarmony-4400 Unit, Bottom panel UGD-D01186 Airspan Commercial and Internal Use 22 AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays the AirHarmony-4400’s top panel. Figure 5: AirHarmony-4400 Unit, Top panel 3.2.5 Physical Dimensions AirHarmony-4400 is in an all outdoor enclosure. Table 10: AirHarmony-4400 Physical Dimensions Variant Dimensions (H x W x D) AirHarmony-4400 509 x 262 x 252 mm / 20.0 x 10.3 x 9.9 inch Weight Main Unit (without filter sets) 19.6 Kg / 43.21 Lbs. Main Unit (with filter sets) 26 Kg / 57.32 Lbs. Universal mounting bracket 3 Kg / 6.6 Lbs. Quadruple Filter Set – Band 41 6 Kg / 13.2 Lbs. UGD-D01186 Airspan Commercial and Internal Use 23 AirHarmony-4400 (External Cavity Filters) Installation Guide 3.2.6 Environmental AirHarmony-4400 meets the following environmental requirements: GR-63 Storage and Transportation ETSI EN 300-019-1-4 Operational (non-weather protected equipment) ETSI EN 300-019-1-1 Storage (weather protected, non-temperature controlled locations) ETSI EN 300-019-1-2 Transportation Table 11: AirHarmony-4400 Environment Compliance Type Details Standard Compliance Operating temperature -40°C to 55°C / -40°F to 131°F ETSI 300 019 1-4 Operating humidity 5% - 100% non-condensing ETSI 300 019 1-4 Storage temperature -40°C to 70°C N/A Storage humidity 5% - 100% non-condensing ETSI 300 019 1-4 Rain and dust ingress protection IP66 N/A 70-106 kPa as well as: Operational altitude From -60m to 1800m @ 40C ETSI 300 019 1-4 From 1800m to 4400m @ 30C Solar radiation UGD-D01186 1120 W/m2 Airspan Commercial and Internal Use ETSI 300 019 1-4 24 AirHarmony-4400 (External Cavity Filters) Installation Guide 4 Installing AirHarmony-4400 Install the AirHarmony-4400 eNodeB by pole/wall mount. AirHarmony-4400 is mounted on a pole or wall in close proximity to its external antenna (connectorized variant). Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4400 on pole or wall. 4.1 Rear External Filter Set Assembly Note: Both External Filters’ sets should be assembled on the AirHarmony-4400 prior to installing on the pole/wall mount. Airspan recommends doing the assembly on a steady secure surface. 1. Remove the upper polyethylene packing foam and set aside for later use. 2. Carefully remove the AirHarmony unit from the packaging and stand on end. Caution: Make sure that the AirHarmony unit is standing securely. 3. Remove the lower polyethylene packing foam and set down. 4. Lie the AirHarmony unit down in the horizontal position on packing foam so as to facilitate assembly of the rear external filters’ set (either Low, High or Full Band). Figure 6: AIrHarmony-4400 - in Horizontal Position prior to Rear External Filters Set Assembly 5. Open the Filters Sets packaging and carefully remove both the front and rear filter sets. 6. Set the rear external filters’ set aside in preparation for assembly. Note: Verify that the required External Filters set are used as there are three (3): AirHarmony 4400 Band 41 Low Filter 2496 - 2568 MHz – with a White label AirHarmony 4400 Band 41 High Filter 2618 - 2690 MHz – with a Black label AirHarmony 4400 Band 41 Full Range Filter 2496 - 2690 MHz – with a Silver label UGD-D01186 Airspan Commercial and Internal Use 25 AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 7: Rear External Filters' Set Note: The Rear External Filters’ Set come assembled with the M5 pan head screws holding the external filters in place on the filter bridge. 7. Align the four screw slots in order to fit the rear external filters’ set in place. 8. Position the rear external filters’ set on the AirHarmony-4400 in position so the slots on the sides align with the M5 pan head screws on the unit’s back plate. 9. Insert all four (4) M5 screws (supplied) and tighten with screwdriver. Figure 8: Mounting Rear External Filters' set 10. Loosen the eight (8) M5 screws on the filters to allow easy alignment of with RF connector. 11. Align the back bracket (over the rear filter set) and once aligned insert the supplied M8x20 Hex head bolt with a split washer and a flat washer into each clinch-nut. UGD-D01186 Airspan Commercial and Internal Use 26 AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 9: Back Bracket Assembly 12. Slide the filter to align it with its RF connector and fit together, then tighten the connector. Figure 10: Fitting RF Connector Caution: Take care not to over tighten the RF connector. The connector nut should be tightened to a nominal torque of no more than 15 [N*m] (11.06 lb-ft). Using either 22 mm or 7/8” open end torque wrench. 13. After tightening both RF connectors, proceed to tighten the eight (8) M5 screws on the filters Figure 11. Tighten the Filter Screws UGD-D01186 Airspan Commercial and Internal Use 27 AirHarmony-4400 (External Cavity Filters) Installation Guide 14. Next tighten the four (4) M8X20 Hex head bolts which fasten the filter to the filter bridge bracket. Figure 12: Tighten Hex Head Bolts Airspan recommends weather-proofing the RF connections. Note: Weather-proofing of all the connections is recommended. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weather-proofing is best done at this stage to give easier access to the connections. Proceed to assemble the front external filter set. 4.2 Front External Filter Set Assembly Note: Both External Filters’ sets should be assembled on the AirHarmony-4400 prior to installing on the pole/wall mount. Airspan recommends doing the assembly on a steady secure surface. 1. Turn the unit over in preparation for the Front External Filters’ set assembly and lie the AirHarmony-4400 down on a flat surface so as to facilitate assembly of the front external filters’ set (either Low, High or Full Band). 2. Place part of the polyethylene packing foam under the unit so as to protect the AirHarmony from getting any scratches. Figure 13: AIrHarmony-4400 in Prone Position Prior to Front External Filter Assembly UGD-D01186 Airspan Commercial and Internal Use 28 AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Take the front external filters’ set in preparation for assembly. Note: Verify that the required External Filters set are used as there are three (3): AirHarmony 4400 Band 41 Low Filter 2496 - 2568 MHz – with a White label AirHarmony 4400 Band 41 High Filter 2618 - 2690 MHz – with a Black label AirHarmony 4400 Band 41 Full Range Filter 2496 - 2690 MHz – with a Silver label Figure 14: External Filters' Set Note: The External Filters’ Set come assembled with the M5 pan head screws holding the external filters in place on the Filter bridge and M5 pan head screws holding the cover on the filter bridge. Figure 15: External Filters' Set slots & fastenings UGD-D01186 Airspan Commercial and Internal Use 29 AirHarmony-4400 (External Cavity Filters) Installation Guide 4. Loosen the four (4) M5 screws on the Sun-Shield in order to fit the External Filters’ set in place. 5. Position the External Filters’ set on the AirHarmony-4400 in position on the Sun-Shield so the slots on the sides align with the M5 pan head screws projecting from the SunShield. Figure 16: Mounting External Filters' set on Sun-shield 6. Loosen the four (4) M5 screws on the filter cover that lock the filter cover in place on the External Filters’ set. 7. Pull up slightly on the filter cover bottom (to release the cover a bit) and pull the cover up and back to open the cover. Figure 17: Opening cover UGD-D01186 Airspan Commercial and Internal Use 30 AirHarmony-4400 (External Cavity Filters) Installation Guide 8. Pull outward on the filter cover to pull it free and swing the filter cover down away from the cavity filters and open the cover completely. Figure 18. Cover opened 9. Slide the filter to align it with its RF connector and fit together, then tighten the connector. Caution: Take care not to over tighten the RF connector. The connector nut should be tightened to a nominal torque of no more than 15 [N*m] (11.06 lb-ft). Using either 22mm or 7/8” open end torque wrench. Figure 19: Align and fit filter to connector 10. Next tighten the four (4) screws which fasten the filter to the filter bridge. UGD-D01186 Airspan Commercial and Internal Use 31 AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 20: Tighten screws on filter 11. Slide the second filter to align it with its RF connector and fit together, then tighten the connector. Caution: Take care not to over tighten the RF connector. The connector nut should be tightened to a nominal torque of no more than 15 [N*m] (11.06 lb-ft). Using either 22mm or 7/8” open end torque wrench. Figure 21: Align and fit second filter to connector 12. Tighten the four (4) screws which fasten the second filter to the filter bridge. 13. Tighten the four (4) screws which fasten the filter bridge to the Sun-Shield. Airspan recommends weather-proofing the RF connections. Note: Weather-proofing of all the connections is recommended. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weather-proofing is best done at this stage to give easier access to the connections. UGD-D01186 Airspan Commercial and Internal Use 32 AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 22: Tighten filter bridge screws on Sun-Shield 14. Swing the filters’ cover up till slots are aligned with the two (2) upper bolts on the filter bridge. 15. Once in place tighten all four (4) screws to lock the filters’ cover in place. Figure 23: Tighten screws on cover Note: The changing or replacing of the external filter sets will require a dismantling of the AirHarmony 4400 from its mounting position to perform this change or replacement. 4.3 Connecting the GPS Antenna After assembly of the External Filters set, the GPS antenna should be connected and it is recommended that the connection should be weather-proofed. The following describes the connection of the GPS antenna which is installed directly to the top of the unit. UGD-D01186 Airspan Commercial and Internal Use 33 AirHarmony-4400 (External Cavity Filters) Installation Guide 1. 2. Unscrew the protective dust cap from the GPS antenna jack prior to mounting on the AirHarmony-4400. Align the GPS jack with the plug attached to the top panel on the AirHarmony-4400. Figure 24: Attaching GPS antenna to unit Caution: Take care not to over tighten so as not to damage the threads. Note: It is good practice to weather-proof all the antenna connections. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weatherproofing the GPS connection is best done at this stage to give easier access to the connections. UGD-D01186 Airspan Commercial and Internal Use 34 AirHarmony-4400 (External Cavity Filters) Installation Guide 4.4 Pole/Wall Mount Assembly Install the AirHarmony-4400 eNodeB by pole/wall mount. AirHarmony-4400 is mounted on a pole or wall in close proximity to its external antenna (connectorized variant). Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4400. 4.4.1 Mounting on a Wooden Pole The following images show the pole mount assembly on a wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. Figure 25: Pole/Wall mounting plate 1. Select the location on the pole to mount the AirHarmony-4400. You can attach the AirHarmony-4400 to any pole from 1-7/8 to 16 inches (47.6 to 406.4 mm) in diameter. 2. Determine where to position the mounting plate on the pole and mark where to drill for insertion of the 3/8-16 through-bolt. Note: Threaded rod and necessary hardware are not supplied by Airspan and are the responsibility of the installer. UGD-D01186 Airspan Commercial and Internal Use 35 AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Drill a minimum 7/16” hole to accept the 3/8-16 threaded rod. 4. Thread the 3/8-16 threaded rod into the provided clinch-nut attached on the Pole/Wall mounting plate. 5. Holding the mounting plate (with the attached threaded rod) pass the 3/8-16 threaded rod through the drilled hole in the pole. 6. Install on the exposed thread that protrudes from pole a flat washer, split washer, and then a 3/8”-16 hex nut and tighten. 7. Insert the clamp bands by passing them through the slots in the mounting plate, in three (3) places. Note: The clamp bands are not supplied by Airspan and are the responsibility of the installer. Clamp bands should not be wider than 15.5 mm in order to fit in the slots on the mounting plate. 8. Tighten the clamp bands with large flat screwdriver. Figure 26: Mounting plate on pole UGD-D01186 Airspan Commercial and Internal Use 36 AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 27: Through-bolt & Mounting plate Mounting plate is installed and ready for AirHarmony-4400 mounting. 4.4.2 Mounting on a Non-Wooden Pole The following images show the pole mount assembly on a non-wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. Figure 28: Pole/Wall mounting plate (w/o bolt) UGD-D01186 Airspan Commercial and Internal Use 37 AirHarmony-4400 (External Cavity Filters) Installation Guide 1. Select the location on the pole to mount the AirHarmony-4400. You can attach the AirHarmony-4400 to any pole from 1-7/8 to 16 inches (47.6 to 406.4 mm) in diameter. 2. Insert the clamp straps through the slots in the mounting plate passing them through the pole clamps. 3. Insert the clamp bands by passing them through the slots in the mounting plate, in four (4) places. Note: The clamp bands are not supplied by Airspan and are the responsibility of the installer. Clamp bands should not be wider than 15.5 mm in order to fit in the slots on the mounting plate. 4. Tighten the clamp bands with large flat screwdriver. Figure 29: Mounting plate mounted 4.4.3 Mounting on a Wall The following images show the wall mount assembly. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. 1. Position mounting plate against the wall with mounting pins facing up. Be sure to position the wall mounting plate straight with level mounting to ensure the unit sits evenly. 2. Mark the wall through the holes on the wall mount at the required height. UGD-D01186 Airspan Commercial and Internal Use 38 AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Attach the mounting plate to the wall using Lag bolts (x8 recommended). Note: Lag bolts (x8) and necessary hardware are not supplied by Airspan and are the responsibility of the installer. Recommended minimum 5/16 x 4” dia. (8mm x 100mm) with appropriate plugs according to field conditions. Figure 30: Mounting Plate on Wall UGD-D01186 Airspan Commercial and Internal Use 39 AirHarmony-4400 (External Cavity Filters) Installation Guide 4.5 Securing AirHarmony-4400 to the Mounting Plate Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4400 on pole or wall. To mount AirHarmony-4400 to the mounting plate, perform the following: 1. Lift up the AirHarmony-4400 unit and hook the slotted holes onto the mounting pins (studs) on the top of the mounting plate. Figure 31: Lift unit and fit the slotted holes unto studs on top of mounting plate UGD-D01186 Airspan Commercial and Internal Use 40 AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays a close up of the Pin (stud) alignment. Figure 32: Align Pins 2. Lean the bottom of the unit into the mounting plate until the six (6) holes are aligned with the six (6) M8 clinch-nuts on the mounting plate. There are two (2) on the top, near the mounting pins and two (2) on either side of the mounting plate for a total of six (6) . 3. Once aligned insert the supplied M8x20 Hex head bolt with a split washer and a flat washer into each clinch-nut. 4. Check and tighten all six (6) M8x20 Hex head bolts. The following displays the AirHarmony-4400 mounted on a wooden pole. Figure 33: AirHarmony mounted on Wooden Pole UGD-D01186 Airspan Commercial and Internal Use 41 AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays the AirHarmony-4400 mounted on a concrete pole. Figure 34: AirHarmony mounted on Concrete Pole UGD-D01186 Airspan Commercial and Internal Use 42 AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays the AirHarmony-4400 being mounted on a wall. Figure 35: AirHarmony being mounted on a Wall UGD-D01186 Airspan Commercial and Internal Use 43 AirHarmony-4400 (External Cavity Filters) Installation Guide 5 AirHarmony-4400 Connections This section describes Grounding procedure, cable preparation and connections and external antenna assembly. 5.1 Grounding The AirHarmony-4400 requires a secure ground connection. The ground cable should be connected with the grounding screw (M6x16) fitted with a flat washer and lock washer (supplied) to the bottom of the chassis clearly marked with the universal ground symbol as shown below. The grounding screw (M6 x 16) is pre-installed during assembly. Figure 36: Grounding The cable should be grounded and bonded according to international or local standards. 5.2 Remote Antenna Assembly The AirHarmony-4400 unit is be used with a remotely attached antenna. For installation of a remotely mounted antenna follow the antenna manufacturer’s instructions and connect the antenna to the AirHarmony-4400 external filter RF connectors (female DIN 4.1/9.5 connector) using the appropriate cables with a male DIN 4.1/9.5 connector. Caution: Take care not over tighten the RF connector. The connector nut should be tightened to a nominal torque of no more than 10.0 Nm (1.47 lb-ft). RF failures can result when the RF connector is over-tightened. 5.2.1 Connecting RF Jumper Cables to External Antenna The following describes how to connect the antenna cables to the cavity filters. 1. Attach, connect and secure the RF cables, with a DIN 4.1/9.5 connector(s) (Male internal thread) coming from the external antenna and the two (2) RF connections on UGD-D01186 Airspan Commercial and Internal Use 44 AirHarmony-4400 (External Cavity Filters) Installation Guide the filter, which has two (2) ports with DIN 4.1/9.5 connectors (Female - external thread) on the top of the cavity filter. Figure 37: DIN 4.1/9.5 connectors (external thread) Caution: Antennas must be connected and attached before AirHarmony is powered on. Caution: Power down AirHarmony prior to disconnecting antenna. 2. Weather-proof the RF connections. Note: The above is also applicable for replacement assembly. 5.2.2 Weather-proofing the Antenna Connections Weather-proofing of all the connections is required. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weather-proofing is best done at this stage to give easier access to the connections. Note: Weather-proofing is best done at the assembly stage to give easier access to the connections. Weather-proofing is to be done to all RF connectors. Verify the RF connectors are completely weather-proof. UGD-D01186 Airspan Commercial and Internal Use 45 AirHarmony-4400 (External Cavity Filters) Installation Guide 5.3 Cable Connections Note: The following images are for illustration purposes only. The actual tools or hardware may differ according to manufacturer. 5.3.1 Copper Ethernet Cable Assembly The following demonstrates the recommended assembly instructions, hardware and tool requirements for the proper Ethernet cable assembly of the Ethernet Category 5e (enhanced) (CAT5e) cable used by Airspan products. The Ethernet cable is connected using a standard RJ45 connector protected by a harsh environment protective casing. Assembly Instructions The Copper Ethernet cable is connected to the AirHarmony-1000 using a Gland connector assembled on the bottom panel of the unit, as shown below. Figure 38: Gland connector - copper 1. Remove the Gland connector by unscrewing the body from the AirHarmony-1000, using the (supplied) Gland wrench. 2. Pass the prepared Ethernet cable through the tail nut, gland seal, body and front seal of the connector casing as shown below. Do not tighten the tail nut. Figure 39: Ethernet Cable through connector UGD-D01186 Airspan Commercial and Internal Use 46 AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Seat the RJ45 connector plug securely into the body cavity of the AirHarmony-4400 4. Tighten the Gland body into to the threaded hole on the bottom of the AirHarmony4400. 5. Tighten the tail nut on to the body using the included Gland wrench, forcing the seal compress around the cable. 6. Once the connector is properly installed, the cable should be positioned and secured to minimize stress on the cable. 5.4 Fiber Ethernet (SFP) Cable Installation The Fiber Ethernet Small form-factor pluggable transceiver (SFP) must be connected to the AirHarmony -4400 using an outdoor fiber cable. The optical connection enables a one-hand installation of the connector. This enables the users to easily remove and replace the SFP transceiver module which eliminates the need to open the unit and expose its contents to hazardous weather conditions. use only SFP which are safety approved IEC 60825 and CDRH with class 1 laser Note: Airspan recommends using the Finisar - FTLF1318P3BTL 1000BASE-LX which has been tested and approved by Airspan. Available from Airspan if required. Note: Use only SFP which are safety approved IEC 60825 and CDRH with class 1 laser. 5.4.1 SFP Cable Connection Figure 40: LC duplex cable assembly 1. Remove the protective dust cap from the connector housing assembled on the unit. 2. Line up the SFP transceiver module with the port and slide it into the port. 3. Connect the cable connector onto the board connector. Figure 41: Cable connector hook up to the board connector UGD-D01186 Airspan Commercial and Internal Use 47 AirHarmony-4400 (External Cavity Filters) Installation Guide 4. Verify that the locking latch on the cable connector is engaged on the board connector. 5. Slide the inner housing and ground shield (if present) over the cable and over the molding. Figure 42: Slide on inner housing Note: Check that there no space between the inner housing and mounting flange. Check and remove any debris that might interfere with the connection. 6. Slide the outer shell over the inner housing and turn the outer bayonet shell 1/4 turn clockwise, until it clicks into place. UGD-D01186 Airspan Commercial and Internal Use 48 AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 43: Slide over and click Note: The shell should be hand tightened only. Do NOT use tools to tighten the shell. Once the connector is properly installed, the cable should be positioned and secured to minimize stress on the cable and connector. 5.5 Connecting the AC Power Cable to AirHarmony-4400 Danger: Hazardous voltage! Before working, ensure that the power is removed from the power connection cables. When the system is powered on, do not touch the power terminals. 5.5.1 Power Cable Preparation Tip: It is good practice to label both ends of the cable to identify which AirHarmony-4400 unit it is connected to. Tip: It is good practice to leave a spare loop of cable (approximately 0.5m). This will allow for easier wiring and will allow the cable to be re-terminated if necessary in the future. Warning: Required - circuit breaker for AC power source -16A for EU installation and 20A for US installation. Minimum – 10A. The power cable is connected to the AirHarmony-4400 connector (marked PWR) on the bottom panel of the unit. 1. Prepare the connector by unscrewing the body pf the AC connector, included in the AirHarmony-4400 package. Figure 44: AC connector UGD-D01186 Airspan Commercial and Internal Use 49 AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 45: AC Connector disassembled 2. Strip back and remove the outer sheath to expose the inner black, white and green insulated wires to a length of 3 cm (1.18 in). Then strip back 6 mm (0.24 in) of the inner core insulation. Figure 46: Strip wire 3. Thread the 3 wire (stranded 18AWG) cable through the tail nut, gland seal, body and rubber gasket of the connector casing as shown below. Do not tighten the tail nut. Figure 47: power cable assembly 4. Insert the stripped wire ends of the cable into the connector sleeves. Figure 48: Connector on cable UGD-D01186 Airspan Commercial and Internal Use 50 AirHarmony-4400 (External Cavity Filters) Installation Guide 5. Secure the wire ends of the power cable into the head part of the connector, as shown below. Figure 49: Plug pins Figure 50: Pin assignment Pin # Wire Color Description White Neutral Black Phase Green Ground Figure 51: Attaching wires 6. Insert into connector, the by alignment pin determines the correct orientation. 7. Tighten the tail nut on to the body forcing the seal to compress around the power cable. Caution: Do not over tighten the connector or the tail nut. The nut should be tightened to a torque of no more than 3.3 Nm (2.43 lb-ft) max. Note: When securing the cable verify there is no tension on the connector so that it is easy to disconnect and re-connect for future maintenance actions. UGD-D01186 Airspan Commercial and Internal Use 51 AirHarmony-4400 (External Cavity Filters) Installation Guide 8. Remove the connector’s protective cap on the bottom panel of the unit. 9. Slide the Connecter Clamp over the connector housing prior to connecting. Figure 52: Connector Clamp 10. Tighten the assembled power cable to the connector. Caution: The internal plastic parts of the mating connector are keyed. Take care to align these by visual inspection or by gently rotating the connector body until the key way sections align and the pins engaged fully before tightening. Figure 53: Power cable attached to AirHarmony-4400 UGD-D01186 Airspan Commercial and Internal Use 52 AirHarmony-4400 (External Cavity Filters) Installation Guide 5.5.2 Securing Connector Clamp Warning: Required – For safety reasons it is imperative to secure the power cable with the Connector clamp after connection. This is to prevent manually disconnecting the power cable. After the power cable is connected securing the connection is required. 1. This is performed by inserting the 2 – M4 x 12 screws into the provided holes and tightening the screws. The clamp covers the connector and prevents access to the connection so it cannot be opened without difficulty. Figure 54: Securing the connection UGD-D01186 Airspan Commercial and Internal Use 53 AirHarmony-4400 (External Cavity Filters) Installation Guide A Job Sheet This job sheet enables the users to keep track of their installation. It covers all the prerequisites required for accomplishing the AirHarmony-4400 installation. Table 12: Job Sheet Site Requirements Pole or wall for installation identified Position on pole or wall identified Pole access restrictions (highway regulations, other services on pole, power pole) Method of reaching pole positions (ladders, Elevated work platform) AC main fuse block available for AC/DC converter (where needed) Configuration programming details known Point of connection for Ethernet (if applicable) All equipment items available at the installation site: ● Main AirHarmony-4400 unit ● External Filter Set – verify required set ● GPS Antenna ● Mounting bracket, through-bolt and pole clamps, or bolts if wall mount ● Copper Ethernet or SFP cable assembly ● Weather-proofing of the connections with a layer of self-amalgamating tape followed by an over layer of PVC tape. Tool Requirements (For further information, see Verify the Tools.) Large flat screw driver Small flat blade screw driver (insulated shaft recommended) Medium Philips head screw driver 13 mm wrench Knife pliers Small side cutters Wire strippers Required Ancillary Equipment Laptop PC for initial configuration Cable for temporary connection of the laptop Other installed materials Cable ties Labels (good to have) UGD-D01186 Airspan Commercial and Internal Use 54 AirHarmony-4400 (External Cavity Filters) Installation Guide B Abbreviations Term Expansion 3GPP 3rd Generation Partnership Project, responsible for LTE ABS Almost Blank Subframes ACS Adjacent Channel Selectivity is a measurement of a receiver's ability to process a desired signal while rejecting a strong signal in an adjacent frequency channel. ACS is defined as the ratio of the receiver filter attenuation on the assigned channel frequency to the receiver filter attenuation on the adjacent channel frequency. AWGN Additive White Gaussian Noise is a channel model in which the only impairment to communication is a linear addition of white noise with a constant spectral density and a Gaussian distribution of amplitude. BER Bit Error Rate CN Core Network CP Cyclic Prefix CTC Convolution Turbo Code is a high-performance forward error correction (FEC) code dB Decibel. A logarithmic unit used to describe a ratio (such as power ratio in radio telecommunications) dBm An abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). It is used as a convenient measure of absolute power because of its capability to express both very large and very small values in a short form. eNodeB Evolved Node B, is the element in E-UTRAN of LTE. ESP Encapsulating Security Payloads (ESP) provide confidentiality, data-origin authentication, connectionless integrity, an anti-replay service (a form of partial sequence integrity), and limited traffic-flow confidentiality E-UTRAN Evolved UMTS Terrestrial Radio Access Network, is the air interface of 3GPP's Long Term Evolution. EVM/RCE The Error Vector Magnitude or EVM (sometimes also called Receive Constellation Error or RCE) is a measure used to quantify the performance of a digital radio transmitter or receiver. It is measured in dB or percentage (%) – the lower the better. FDD Frequency-Division Duplexing. A transceiver mode where the transmitter and receiver operate at different carrier frequencies. GNSS Global Navigation Satellite System is a term used to describe a satellite navigation system with global coverage. There are currently two fully operational GNSSs – the US GPS and the Russian GLONASS GTP-U GPRS Tunneling Protocol for User data is a relatively simple IP based tunneling protocol which permits many tunnels between each set of end points HPBW Half Power BandWidth is the angular separation in an antenna, in which the magnitude of the radiation pattern decreases by 50% (or -3 dB) from the peak of the main beam ICS In-channel selectivity is a measure of the receiver’s ability to receive a wanted signal at its assigned Resource Block locations in the presence of an interfering signal IPSec Internet Protocol Security is a protocol suite for securing Internet Protocol (IP) communications by authenticating and encrypting each IP packet of a communication session LED Light Emitting Diode LTE Long Term Evolution MAC Medium Access Controller – responsible for several functions such Error Correction, Packet (De)Multiplexing, etc… MBSFN Multicast-Broadcast Single Frequency Network is an LTE feature designed to deliver services such as Mobile TV using the LTE infrastructure, and is expected to be a competitor to DVB-Hbased TV broadcast MCS Modulation and Coding Scheme UGD-D01186 Airspan Commercial and Internal Use 55 AirHarmony-4400 (External Cavity Filters) Installation Guide Term Expansion MME Mobility Management Entity is the key control-node for the LTE access-network. It is responsible, among other things for idle mode UE tracking and paging procedure including retransmissions MTBF Mean Time Between Failures OFDMA Orthogonal Frequency-Division Multiple Access (OFDMA) is a multi-user version of OFDM digital modulation scheme, used for eNodeB transmissions to UEs PDCP Packet Data Convergence Protocol. A Sub-Layer in LTE responsible for IP Header (De)Compression, etc… PDU Protocol Data Unit PTP Precision Time Protocol is used to synchronize clocks throughout a network. In this document, PTP is referring to IEEE1588-2008 protocol RB Resource Block RLC Radio Link Control. A Sub-Layer in LTE responsible for Ack/Nack, error correction, packet reordering, etc… ROHS Restriction Of Hazardous Substances RRM Radio Resource Management is used to cover all functions that are related to the assignment and sharing of radio resources among UEs S-GW Serving Gateway. A Core entity in the LTE EPC architecture responsible for routing and forwarding user data packets, while also acting as the mobility anchor for the user plane during inter-eNodeB handovers and as the anchor for mobility between LTE and other 3GPP technologies SBA Switched Beam Antenna SC-FDMA Single-Carrier FDMA is a frequency-division multiple access scheme, dealing with the assignment of multiple users to a shared communication resource. Used in LTE for UE transmissions to the eNodeB SCTP Stream Control Transmission Protocol is a reliable transport layer protocol, ensuring insequence transport of messages with congestion control like TCP SDR Software Defined Radio TDD Time-Division Duplexing. A transceiver mode where the transmitter and receiver operate on the same carrier frequency UE User Equipment. The end user in LTE WEEE Waste Electrical and Electronic Equipment UGD-D01186 Airspan Commercial and Internal Use 56
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : M Falik Create Date : 2016:12:04 13:50:22+02:00 Keywords : Rev, A Modify Date : 2016:12:12 06:46:51+02:00 Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : M Falik Title : AirHarmony 4400 ext Installation Guide Subject : Rev A Creator Tool : Microsoft® Word 2013 Metadata Date : 2016:12:12 06:46:51+02:00 Producer : Microsoft® Word 2013 Document ID : uuid:a08002b4-3c97-4ed7-a94b-005daf78aead Instance ID : uuid:b9dc323b-2007-4ee1-bd3a-791edc95eba1 Page Count : 62EXIF Metadata provided by EXIF.tools