Alarm Lock ArchiTech_Type_2_WI2090A.07_INST Archi Tech_ By Networx_: For Mortise Locks Using Surface Mounted Networx Control Units Tech Type 2 WI2090A.07 INST
User Manual: Alarm Lock ArchiTech_ by Networx_: For Mortise Locks Using Surface-Mounted Networx Control Units Installation Manuals
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
ArchiTech™ by Networx™ FOR MORTISE LOCKS USING SURFACE-MOUNTED NETWORX CONTROL UNITS MOUNTING AND INSTALLATION INSTRUCTIONS © NAPCO Security Technologies, Inc. 2015 WI2090A 05/15 DESCRIPTION These instructions detail the hardware installation procedure for the ArchiTech mortise door locks using the SurfaceMounted Networx Control Units for hollow metal and solid wood doors. Installation instructions for the Door Contact Sensor, Door Contact Magnet (installed in the door jamb) and the Oval and Rectangular Proximity Readers are also included. PARTS OVERVIEW For reference, the images in Fig. A below display each component (not to scale). In addition to the various screws included with your mortise lock, please be aware that two types of Proximity Readers are available (either Oval or Rectangular) but only one type is included with your lock. Furthermore, one of two types of Door Contact Magnets (installed in door jamb) are included (either 3/8" or 3/4" diameter). We recommend taking the time to read through these instructions, find and familiarize yourself with each component before you begin your installation. As detailed in the instructions that follow, the Proximity Reader wire, the Door Contact Sensor wire and the Mortise Lock Motor Wire are routed through the door and are plugged into the Surface-Mounted Networx Control Unit. The Mortise Lock Motor Wire can easily be routed within hollow metal doors. For solid wood doors, a Mortise Drill Jig (part #N95I1DJ) must be used to drill a hole pathway within the solid wood door to route the Mortise Lock Motor Wire. OR OVAL AND RECTANGULAR PROXIMITY READER COVERS AND MOUNTING COMPONENTS DOOR CONTACT SENSOR "SURFACE-MOUNTED" NETWORX CONTROL UNIT AND ITS MOUNTING PLATE DOOR CONTACT MAGNET (TWO TYPES) MORTISE DRILL JIG (N95I1DJ) (SOLID WOOD DOORS ONLY) FIG. A: OVERVIEW OF BASIC PARTS (NOT TO SCALE) REQUIRED TOOLS In addition to the standard door prep kit tools used to install a mortise lock into a metal or wood door (Phillips and flat head screwdrivers, etc.), you will need: A small level, and the following drill bit sizes: 5/8", 3/8", 3/4" and 7/64". ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 1 DOOR PREP: INITIAL STEPS 1. INSPECT THE DOOR BEVEL Inspect the door for a bevel and, if beveled, determine which side is "longer" in width and which side is "shorter" in width (see "top view" example in Fig. 1). For beveled doors, be sure to use the correct marks printed on the template for the correct length of the outside door surface (either the "long" or "short" side of the door). "Shorter side of door" Door Stop DOOR 3½° bevel Jamb "Longer side of door" Arc of door swing FIG. 1: EXAMPLE OF BEVELED DOOR (TOP VIEW) 2. PREP DOOR FOR MORTISE LOCK If not done already, use standard door prep kit tools and the instructions included with the mortise lock to prep the door and door jamb as required. These include mortising the door edge for the latch plate and mortising the door jamb for the strike plate. Do not install the lock hardware yet. FIG. 2: USE TEMPLATE PROVIDED 2 ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 3. TAPE ON DOOR: "PROXIMITY READER" TEMPLATE (WI2102) Remember, the Proximity Reader is always located on the outside ("unprotected" side) door surface. Fold and place the template (WI2102) on the outside door edge (see arrow in Fig. 3 for an example). Align the template with the "HORIZONTAL CENTER LINE OF LEVER" as shown on the template. Tape the template in place. FIG. 3: EXAMPLE OF OUTSIDE DOOR EDGE (ARROW) 4. MARK TEMPLATE "PROXIMITY READER" HOLES On the outside door surface, mark the two holes for the Proximity Reader mounting screws. Mark the center of the 5/8" Diameter Thru-Hole (used for the Mortise Lock Motor Wire, Proximity Reader and Door Contact Sensor wires). Do NOT remove the template yet. TIP: Take special notice of this 5/8" Diameter Thru-Hole, as it is an essential hole for this installation and is referenced several times throughout these instructions. FIG. 4. EXAMPLE CLOSE UP OF WI2102 TEMPLATE FOR THE "PROXIMITY READER" ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 3 5. MARK TEMPLATE "DOOR CONTACT SENSOR" HOLE Mark the 3/4" Door Contact Sensor hole in the center edge of the door (adjust for the door thickness). Carefully remove the template. FIG. 5A: HOLE LOCATION DEPENDS ON DOOR THICKNESS FIG. 5: DOOR CONTACT SENSOR HOLE ON DOOR EDGE 6. MARK "DOOR CONTACT MAGNET" ON JAMB The Door Contact Magnet must be installed in the door jamb such that when the door is closed, the Door Contact Sensor is located directly opposite the Magnet. Install as follows: 6A. Open the door and temporarily place a piece of tape across the center of the mark made for the Door Contact Sensor in the previous step. This tape signifies the height (from the floor) of the Door Contact Sensor. 6B. Close the door. Transfer this height to the door jamb with a light pencil mark. 6C. Determine the center location on the jamb directly opposite the Door Contact Sensor when the door is closed. Open the door and measure the distance from the door edge to the center of the Door Contact Sensor (0.875" or ⅞"). Transfer this distance to the door jamb, measured from the door stop. FIG. 6A: TAPE SIGNIFIES "HEIGHT FROM FLOOR" 4 FIG. 6B: CLOSE DOOR AND TRANSFER HEIGHT TO JAMB FIG. 6C: LOCATE MAGNET IN JAMB CENTERED DIRECTLY OPPOSITE THE SENSOR WHEN DOOR IS CLOSED ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 7. TAPE ON DOOR: "SURFACE-MOUNTED NETWORX CONTROL UNIT" TEMPLATE (WI2103) The Surface-Mounted Networx Control Unit (see Fig. A on page 1) is always mounted on the inside ("protected" side) door surface. Fold and place the template (WI2103) on the inside door edge. Align the template with the "HORIZONTAL CENTER LINE OF LEVER" as shown on the template. Tape the template in place. FIG. 7: EXAMPLE OF INSIDE DOOR EDGE (ARROW) 8. MARK TEMPLATE "SURFACE-MOUNTED NETWORX CONTROL UNIT" HOLES On the inside ("protected") door surface, mark the two Control Unit Mounting Plate (Fig. 8) holes using the correct markings printed on the template (if door is beveled, use correct markings for beveled doors as described in step 1). The center of the 5/8" Diameter Thru-Hole was already marked on the outside surface in step 4; for the inside door surface, mark the center of this same 5/8" Diameter Thru-Hole. This 5/8" Diameter Thru-Hole is used for the Mortise Lock Motor Wire, Proximity Reader and Door Contact Sensor wires. Carefully remove the template. FIG. 8: MARK THE TWO "CONTROL UNIT MOUNTING PLATE" HOLES (ARROWS) ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 5 DOOR PREP: DRILL HOLES IMPORTANT: Remove all burrs from wire holes. Sharp edges can eventually wear away wire insulation. 9. DRILL THE FOLLOWING HOLES IN THE DOOR 9A. Use 7/64" drill bit: On the outside ("unprotected side") door surface, drill the two pilot holes for the Proximity Reader mounting screws (NOT thru-holes, drill only into the door surface). 9B. Use 7/64" drill bit: On the inside ("protected side") door surface, drill the two pilot holes for the Control Unit Mounting Plate mounting screws (NOT thru-holes). Drill only into the inside door surface. FIG. 9A: 7/64" PILOT HOLE ON OUTSIDE DOOR SURFACE FOR PROXIMITY READER FIG. 9B: 7/64" PILOT HOLE ON INSIDE DOOR SURFACE FOR CONTROL UNIT PLATE 9C. Use 5/8" drill bit: 5/8" Diameter Thru-Hole. Drill straight through the door. FIG. 9C: 5/8" DIAMETER THRU-HOLE 9D. Use 3/4" drill bit: 3/4" Door Contact Sensor hole in edge of the door (for solid wood doors, drill until the hole intersects with the 5/8" Diameter Thru-Hole). "DOOR CONTACT SENSOR" HOLE (3/4") IN EDGE OF DOOR (5/8" DIAMETER THRU-HOLE, DRILLED IN STEP 9C) FIG. 9D: 3/4" DOOR CONTACT SENSOR HOLE IN EDGE OF THE DOOR 6 ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 10. DRILL "DOOR CONTACT MAGNET" HOLE IN JAMB 10A. Find the Door Contact Magnet. The type provided will be either Type A (3/4" dia.) or Type B (3/8" dia.) as shown in one of the two images in Fig. 10A below. 10B. Drill into the door jamb as follows: For Hardwood Jambs: For the thicker "Type A" contact (below left image): Drill a 3/4" hole 7/8" deep into the jamb (marked in step 6). For the thinner "Type B" contact (below right image): Drill a 3/8" hole 7/8" deep into the jamb (marked in step 6). For Hollow Metal Jambs: Use either a 3/4" or 3/8" bit (depending on Door Contact Magnet Type A or Type B) to drill a hole into the surface of the jamb. Type A (3/4" dia.) Φ 31/32" Type B (3/8" dia.) Φ 7/16" FIG. 10A: FIND THE "DOOR CONTACT MAGNET" PROVIDED, EITHER TYPE A (3/4" DIAMETER) OR TYPE B (3/8" DIAMETER) FIG. 10B: DRILL DOOR JAMB HOLE (EITHER 3/8" OR 3/4" DEPENDING ON TYPE) 10C. Insert the magnetic Door Contact Magnet in the jamb hole; the contact sits almost flush with the jamb when fully inserted. In some cases, an adhesive may be needed to ensure a secure fit. FIG. 10C: DOOR CONTACT MAGNET INSTALLED IN DOOR JAMB ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 7 DECISION: HOW TO ROUTE THE MORTISE LOCK MOTOR WIRE? The Mortise Lock body includes a Mortise Lock Motor Wire plug that must be routed to and plugged into the Surface-Mounted Networx Control Unit that is mounted on the inside ("protected side") of the door. HOW this Motor Wire is routed depends on whether the door is solid or hollow: Hollow Metal Doors: Simply route the Mortise Lock Motor Wire within the hollow metal door. Skip to step 12. Solid Wood Doors: Use the Mortise Drill Jig (part #N95I1DJ) to drill a pathway for the wire within the solid wood door (from the Mortise Lock body to the 5/8" Diameter Thru-Hole). Skip to step 11, below. 5/8" THRU -HOLE 11. USING THE MORTISE DRILL JIG The Mortise Drill Jig (part #N95I1DJ) MUST be used with solid wood doors. For hollow metal doors, skip to step 12. PURPOSE OF THE MORTISE DRILL JIG The Mortise Drill Jig is used to drill a diagonal 1/2" hole through solid wood doors to provide path for the Mortise Lock Motor Wire to run within the door and to be plugged into the back of the Surface-Mounted Networx Control Unit. In the steps that follow, the Jig will be secured to the edge of the door (in the same location as the mortise lock faceplate). The hole will be drilled within the door, as shown in profile on the template WI2102 and also in the Fig. 11 "side view" showing where this Mortise Drill Jig is positioned and the path of this drilled interior hole. 11A. FASTEN DRILL JIG TO DOOR The Mortise Drill Jig (part #N95I1DJ) is placed into the edge of the door, into the same mortised opening that will be used for the Mortise Lock. Proceed as follows: Insert the Jig into the Mortise Lock opening as shown in Fig. 11A. Secure the Jig with the screws provided to prevent the Jig from shifting when in use. JIG FIG. 11: SIDE VIEW: DRILL JIG (N95I1DJ) DRILL HOLE INSIDE DOOR Insert supplied 1/2-inch diameter wood drill bit into the Mortise Drill Jig and drill the hole until the 5/8" Diameter Thru-Hole is reached. When finished, remove the Jig. FIG. 11A: MORTISE DRILL JIG PLACEMENT 8 ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 12. INSTALL THE "MORTISE LOCK BODY" Insert the Mortise Lock Body into the door while feeding the Mortise Lock Motor Wire through to the 5/8" Diameter Thru -Hole and then to the inside (" protected" ) side of the door. Note: The Mortise Lock Motor Wire plug sleeve color is yellow. Referencing the lock installation instructions, secure the Mortise Lock with the mounting hardware provided. FIG. 12: ROUTE MORTISE LOCK WIRES THRU TO THE PROTECTED SIDE OF THE DOOR 13. INSTALL "DOOR CONTACT SENSOR" IN DOOR EDGE Insert the Door Contact Sensor wires into its 3/4" hole in the door edge and through to the 5/8" Diameter Thru-Hole and then to the inside ("protected") side of the door. Note: The Door Contact Sensor plug sleeve color is white. FIG. 13: ROUTE TO THE INSIDE ("PROTECTED") SIDE OF THE DOOR DOOR CONTACT SENSOR FIG. 13A ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 9 PROXIMITY READER INSTALLATION Find the reader type provided, either rectangular or oval. If you have a Rectangular Proximity Reader, go to step 15. If you have an Oval Proximity Reader, go to step 14 below. Option 1 Option 2 FIG. C: OVAL PROXIMITY READER (GO TO STEP 14 BELOW) FIG. D: RECTANGULAR PROXIMITY READER (GO TO STEP 15) DO NOT USE POWER DRILLS OR POWER SCREWDRIVERS WHEN INSTALLING THE PROXIMITY READER ! 14. OVAL PROXIMITY READER INSTALLATION If you have a "Rectangular" Proximity Reader, go to step 15. Note that the Oval Mounting Plate is symmetrical, and therefore has no "top" or "bottom". 14A. INSTALL THE "OVAL RUBBER GASKET" AND THE "OVAL MOUNTING PLATE" See Fig. 14A. Place the Oval Rubber Gasket against the door surface, over the 5/8" Diameter Thru-Hole that was drilled into the door in step 9C. Place the Oval Mounting Plate on top of the Oval Rubber Gasket, and secure (snug-tight only, do not overtighten) using the two Phillips Pan Head screws appropriate for the door type as follows: For Metal Doors: #6-32 x 1/2" long Type F thread cutting Phillips head (part #SC212); OVAL Left Tab Thru-Hole Right Tab Oval Rubber Gasket Oval Mounting Plate For Wood Doors: #6 x 1/2" long Type A Phillips head (part #SC265) FIG. 14A: "OVAL MOUNTING PLATE" (WITH LEFT AND RIGHT "TABS") AND THE "OVAL RUBBER GASKET" Again, do NOT over-tighten these screws; overtightening will cause undesired deformation of the Rubber Gasket. 10 ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 14B. RUN THE OVAL PROXIMITY READER WIRES From the outside ("unprotected" side) of the door, feed the Proximity Reader wire fully into the 5/8" Diameter ThruHole to the inside (" protected" side) of the door. Do not pinch wire. Note: The Oval Proximity Reader plug sleeve color is orange. FIG. 14B: FEED THE WIRE INTO THE 5/8" DIAMETER THRU-HOLE (FROM "OUTSIDE" TO "INSIDE") 14C. INSTALL OVAL PROXIMITY READER COVER The Oval Proximity Reader cover "snaps" into place, as follows: a. Hook the Reader on the Left Tab of the Mounting Plate. b. Keep thumb pressure on left side. FIG. 14C c. Press firmly on the right side of the Reader until it "snaps" into place. Note: A spare Mounting Plate and Rubber Gasket are provided if needed. Be careful not to pinch any wires. FIG. 14CC ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 11 15. RECTANGULAR PROXIMITY READER INSTALLATION The Rectangular Mounting Plate IS NOT symmetrical, and therefore does have a "top" and a "bottom". Note the two Top Tabs and two Bottom Tabs shown in Fig. 15A: 15A. INSTALL THE "RECTANGULAR RUBBER GASKET" AND THE "RECTANGULAR MOUNTING PLATE" See Fig. 15A. Place the Rectangular Rubber Gasket over the 5/8" Diameter Thru-Hole that was drilled into the door in step 9C, then place the Rectangular Mounting Plate on top of the Rectangular Rubber Gasket, and secure (snug-tight only, do not overtighten) using the two Phillips Pan Head screws appropriate for the door type as follows: For Metal Doors: #6-32 x 1/2" long Type F thread cutting Phillips head (part #SC212); RECTANGULAR Top Tab Rectangular Rubber Gasket Top Tab Thru-Hole Bottom Tab Rectangular Mounting Plate Bottom Tab For Wood Doors: #6 x 1/2" long Type A Phillips head (part #SC265) FIG. 15A: "RECTANGULAR PROXIMITY READER MOUNTING COMPONENTS Again, do NOT over-tighten these screws; overtightening will cause undesired deformation of the Rubber Gasket. 15B. RUN THE RECTANGULAR PROXIMITY READER WIRES From the outside ("unprotected" side) of the door, feed the Rectangular Proximity Reader wire fully into the 5/8" Diameter Thru-Hole to the inside (" protected" side) of the door. Do not pinch wire. Note: The Rectangular Proximity Reader plug sleeve color is orange. FIG. 15B: FEED THE WIRE INTO THE 5/8" DIAMETER THRU-HOLE (FROM "OUTSIDE" TO "INSIDE") 12 ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 15C. INSTALL RECTANGULAR PROXIMITY READER COVER The Rectangular Proximity Reader cover "snaps" into place, as follows: a. Hook the Rectangular Proximity Reader on the two Top Tabs on the top of the Rectangular Mounting Plate (see Fig 15C). FIG. 15C b. Press firmly on the bottom of the Rectangular Proximity Reader until it " snaps" into place. Be careful not to pinch any wires. FIG. 15CC 16. INSTALL "CONTROL UNIT MOUNTING PLATE" Locate the two pilot holes for the Control Unit Mounting Plate mounting screws that were drilled into the inside ("protected") door surface in step 9B. Important! See Fig 16 to determine which end is the " TOP" . (TOP) Place the Control Unit Mounting Plate against the inside ("protected" side) door surface and secure using the two Phillips Flat Head screws appropriate for the door type as follows: For Metal Doors: #6-32 x 5/8" long Type 23 thread cutting Phillips Flat head, U-cut (part #SC682); For Wood Doors: #6 x 3/4" long undercut selftapping Type A (part #SC596) (BOTTOM) FIG. 16: CONTROL UNIT MOUNTING PLATE ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 13 17. CONNECT PLUGS IN THE "SURFACE-MOUNTED NETWORX CONTROL UNIT" Match the plug wire sleeve colors to the corresponding socket dot colors (see Fig. 17). Note: The rear of the SurfaceMounted Networx Control Unit has five (5) sockets, but only three (3) are used. (ORANGE) Proximity Reader J4 (YELLOW) Lock Motor Wire DO NOT USE (Reserved for future use) (WHITE) Door Contact Sensor (J4) Battery Pack FIG. 17: CONTROL UNIT CONNECTIONS 18. CONNECT THE BATTERY PACK See Fig. 18 for the location of the Battery Pack socket. Place the Battery Pack into the rear of the Surface-Mounted Networx Control Unit with the flat side up, as shown in Fig. 18: FIG. 18: INSTALL BATTERY PACK WITH FLAT SIDE UP 14 ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 19. MOUNT THE "SURFACE-MOUNTED NETWORX CONTROL UNIT" Before mounting, we recommend feeding all of the previously connected wires back into the door. a. Hook the top of the Surface-Mounted Networx Control Unit into the top of the Control Unit Mounting Plate and press the bottom until flush with the door surface. b. Insert the "Dog Point" screw into the bottom of the Surface-Mounted Networx Control Unit (#6-32 Allen Head countersunk U-cut Dog Point screw, part #SC681 as shown in Fig. 19). First thread this screw by hand using the knurled head for grip, then tighten with the "rounded head" of the supplied Allen key. FIG. 19: "DOG POINT" SCREW FIG. 19A: INSERT "DOG POINT" SCREW HERE ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 15 ArchiTech Networx Limited Warranty NAPCO Security Technologies, Inc. (NAPCO) warrants its products to be free from manufacturing defects in materials and workmanship for twenty four months following the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user. This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial numbers have been altered, defaced or removed. Seller will not be responsible for any dismantling or reinstallation charges, environmental wear and tear, normal maintenance expenses, or shipping and freight expenses required to return products to NAPCO. Additionally, this warranty shall not cover scratches, abrasions or deterioration due to the use of paints, solvents or other chemicals. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF NAPCO. Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be brought within the six months following the end of the warranty period. IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. In case of defect, contact the security professional who installed and maintains your security system. In order to exercise the warranty, the product must be returned by the security professional, shipping costs prepaid and insured to NAPCO. After repair or replacement, NAPCO assumes the cost of returning products under warranty. NAPCO shall have no obligation under this warranty, or otherwise, if the product has been repaired by others, improperly installed, improperly used, abused, altered, damaged, subjected to accident, nuisance, flood, fire or acts of God, or on which any serial numbers have been altered, defaced or removed. NAPCO will not be responsible for any dismantling, reassembly or reinstallation charges, environmental wear and tear, normal maintenance expenses, or shipping and freight expenses required to return products to NAPCO. Additionally, this warranty shall not cover scratches, abrasions or deterioration due to the use of paints, solvents or other chemicals. 16 This warranty contains the entire warranty. It is the sole warranty and any prior agreements or representations, whether oral or written, are either merged herein or are expressly cancelled. NAPCO neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products. In no event shall NAPCO be liable for an amount in excess of NAPCO's original selling price of the product, for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of the product. Seller's warranty, as hereinabove set forth, shall not be enlarged, diminished or affected by and no obligation or liability shall arise or grow out of Seller's rendering of technical advice or service in connection with Buyer's order of the goods furnished hereunder. NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY. Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal tampering, electrical or communications disruption, it is possible for the system to fail to perform as expected. NAPCO does not represent that the product/system may not be compromised or circumvented; or that the product or system will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; nor that the product or system will in all cases provide adequate warning or protection. A properly installed and maintained alarm may only reduce risk of burglary, robbery, fire or otherwise but it is not insurance or a guarantee that these events will not occur. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. Therefore, the installer should in turn advise the consumer to take any and all precautions for his or her safety including, but not limited to, fleeing the premises and calling police or fire department, in order to mitigate the possibilities of harm and/or damage. NAPCO is not an insurer of either the property or safety of the user's family or employees, and limits its liability for any loss or damage including incidental or consequential damages to NAPCO's original selling price of the product regardless of the cause of such loss or damage. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, or differentiate in their treatment of limitations of liability for ordinary or gross negligence, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights and you may also have other rights which vary from state to state. ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : dblock Create Date : 2015:05:07 11:31:42-04:00 Modify Date : 2015:05:07 11:31:42-04:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : ArchiTech_Type_2_WI2090A.07_INST.pub Creator : dblock Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:13a51b3c-3b91-454e-9be5-cb1fdeb0405a Instance ID : uuid:52378d8c-0749-4d09-aeb5-2602ce6d0345 Page Count : 16EXIF Metadata provided by EXIF.tools