Alcatel Lucent USA ONEBTS-11 UMTS-CDMA Transceiver System (850) User Manual 401703454i1
Alcatel-Lucent USA Inc. UMTS-CDMA Transceiver System (850) 401703454i1
Contents
users manual c
Overview of the Flexent‚ Modular Cell 4.0B cabinet installation - EZBFo #1 - EZBFo - #2 or EZBFo #2 - EZBFo - #1 - Primary 4.0B Dual Band 4.0B - EZBFo #1 - EZBFo - #2 WNG. BATTERY CABINET 2 * (OPTIONAL) WNG. BATTERY CABINET 1 * (OPTIONAL) CABINET 1 1 " OPTIONAL PORTS FOR ALARMS CABINET 2 JUMPER CABLE SUPPORT STRUCTURE ASSEMBLY (BY CUSTOMER) 2" CONDUIT ASSEMBLYFOR T1/E1 AND USER ALARMS ( TYP ) GPS SURGE PROTECTION 2" CONDUIT ASSEMBLY FOR AC POWER ( TYP ) GPS ANTENNA CABLE PLATFORM (BY CUSTOMER) REAR SURGE PROTECTION (TYP) 2" CONDUIT ASSEMBLY FOR AC POWER ( TYP ) 7/16" DIN FEMALE CONNECTORS ( TYP ) RF ANTENNA CABLES TO ANTENNA TOWER ( TYP ) MOUNTING BASE ( TYP ) ( OPTIONAL ) ANTENNA JUMPER CABLES ( TYP ) Modular Cell 4.0B cabinet side view 1 Illustrated below is an outdoor site with antenna and T1/E1 routing at the top rear of the cabinet. The figure shows a side view of the Modular Cell 4.0B cabinet with a sound muffler and front heat exchanger. Note ........................................................................................................................................................................................................................................................... 1 - 26 Lucent Technologies – Proprietary See notice on first page 401-703-454 FOA Draft Issue 1 January, 2006 Overview of the Flexent‚ Modular Cell 4.0B cabinet installation the fact that a junction box may be installed, where noted, to facilitate routing of AC to a second cabinet. SIDE VIEW 1 (4.0B) NOTE: THE OPTIONAL REAR HEAT EXCHANGER IS NOT ILLUSTRATED IN THIS VIEW. IT IS PART OF THE LUCENT EQUIPMENT Modular Cell 4.0B cabinet side view 2 Illustrated below is an outdoor site with antenna and T1/E1 routing from the bottom to the top rear of the cabinet. The cabinet is illustrated with a rear heat exchanger. The dotted box at the front of the cabinet ............................................................................................................................................................................................................................................................ 401-703-454 FOA Draft Issue 1 January, 2006 Lucent Technologies – Proprietary See notice on first page 1 - 27 Overview of the Flexent‚ Modular Cell 4.0B cabinet installation illustrates the mutually exclusive optional front heat exchanger. Note the fact that a junction box may be installed, where noted, to facilitate routing of AC to a second cabinet. SIDE VIEW 2 (4.0B) (E -IN IQ )P (1 -T ID )L -C IN IM -P IX .M (U IG -9 /O -H IN )I-G IT -P (A IN (O IR IT -H )D IN (O IO )# (2 IR NOTE: THE SOUND MUFFLER MOUNTED ON THE REAR OF THE CABINET IS NOT ILLUSTRATED IN THIS VIEW. IT IS PART OF THE LUCENT EQUIPMENT ........................................................................................................................................................................................................................................................... 1 - 28 Lucent Technologies – Proprietary See notice on first page 401-703-454 FOA Draft Issue 1 January, 2006 Overview of the Flexent‚ Modular Cell 4.0B cabinet installation Torque requirements ............................................................................................................................................................................................................................................................. Overview Torque requirements for mechanical connections This section provides mechanical torque requirements. Refer to the table below. The table below identifies the torque requirements to be followed when making mechanical connections. Torque Item Description Newton Meters Inch Pounds Antenna jumper cable connections 25 221 GPS cable connections at Modular Cell 4.0/4.0B cabinet 25 221 M6 x 16-mm thread rolling screw 30 All other M6 fasteners (nuts, hex-head bolts, etc.) 30 All M5 fasteners (pan-head screws, hex nut, etc.) 30 All M4 fasteners (pan-head screws, hex nut, etc.) 1.5 14 Tamper-proof screws 1.7 - 2.3 15 - 20 ............................................................................................................................................................................................................................................................ 401-703-454 FOA Draft Issue 1 January, 2006 Lucent Technologies – Proprietary See notice on first page 1 - 29 Overview of the Flexent‚ Modular Cell 4.0B cabinet installation Torque specifications for electrical connections Important! The table below must not be used for spanner head self-tapping screws, in or on cabinets. It is to be used exclusively for electrical connections. Refer to the previous table for mechanical connections. The table below identifies the torque requirements to be followed when making electrical connections. Torque - in.-lb. [or ft.-lb.] and (Nm) Metric Screw Size SAE Screw Size M4 Wire Connections Head Tightened Nut Tightened Slotted Machine Hex or Socket Cap Slotted Machine Hex or Socket Cap Slotted Machine Hex or Socket Cap 8-32 15 (1.7) 15 (1.7) 19 (2.1) 19 (2.1) 19 (2.1) 23 (2.6) M5 10-24 21 (2.4) 21 (2.4) 27 (3.1) 27 (3.1) 27 (3.1) 33 (3.7) M6 1/4-20* 50 (5.6) 50 (5.6) 65 (7.3) 65 (7.3) 65 (7.3) 80 (9.0) M8 5/16-18** 100 (11.3) 135 (15.3) 135 (15.3) 165 (18.6) M10 3/8-16 180 (20.3) 240 (27.1) 240 (27.1) 290 (32.8) M12 7/16-14 280 (31.6) 385 (43.5) 385 (43.5) 465 (52.5) M14 1/2-13 500 (56.5) 585 (66.1) 585 (66.1) 710 (80.2) M16 5/8-11 [71] (96.3) [97] (131.5) [97] (131.5) [118] (160.0) M20 3/4-10 [125] (169.5) [172] (233.2) [172] (233.2) [209] (283.4) Table Notes: *Do not use 65 in.-lb. (7.3 Nm) or 80 in.-lb. (9.0 Nm) for battery connections. Use 60 in.-lb. (6.8 Nm) instead. **Do not use 135 in.-lb. (15.3 Nm) or 165 in.-lb. (18.6 Nm) for power cabinet DC connections at the Modular Cell 4.0B cabinet. Use 75 in.lb. (8 Nm) instead. ........................................................................................................................................................................................................................................................... 1 - 30 Lucent Technologies – Proprietary See notice on first page 401-703-454 FOA Draft Issue 1 January, 2006 Overview of the Flexent‚ Modular Cell 4.0B cabinet installation Tools, supplies, and parts required (master list) ............................................................................................................................................................................................................................................................. Overview Tools This section provides a master list of all tools, materials, and parts required during the installation process. Items required for installation of a specific cabinet or frame are listed within the applicable chapter. The following is a master list, in alphabetical order, of all tools that may be utilized during installation. • #8 drilled spanner driver (for tamper-proof screws on outdoor Modular Cell cabinets) • #14 drilled spanner driver (for tamper-proof screws on outdoor Modular Cell cabinets) • 7/16-inch thin-walled nut driver (not provided with cabinets) • Adjustable open-ended wrench (or set of fixed open-ended wrenches) • Antioxidant compound • B connecting links, or equivalent (quantity: 3) • Bolt anchor setting tool • Bonding clamps for facility and phone line cables (normally provided by telephone company) • Bonding kits for antenna cables • B sealing tape • Butyl rubber tape • Chalk line • Channel-lock pliers [for 2-1/2 inch nuts, max. 3/4-inch (19 mm) wide] • Channel-lock pliers (standard) • Crimping tools 22-16 gauge, 10-4/0 gauge (5-120 mm2) • Derrick, capable of supporting a 1500-lb. (680-kg) load • DIN connector stripping tool: part numbers • • For Huber Suhner cable/connector: 74Z-0-12-15 • For Andrew cable/connectors: ITE-7189 • For RFS cable/connectors: TRIM-L12-A Drill and drill bits (including 5/8" [16-mm] and 11/16"[18-mm] for drilling anchor holes) ............................................................................................................................................................................................................................................................ 401-703-454 FOA Draft Issue 1 January, 2006 Lucent Technologies – Proprietary See notice on first page 1 - 31
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2006:03:08 15:51:51-05:00 Create Date : 2006:03:06 14:56:09-05:00 Title : 401703454i1.book Creator : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 5.0.5 (Windows) Page Count : 6 Mod Date : 2006:03:08 15:51:51-05:00 Creation Date : 2006:03:06 14:56:09-05:00 Metadata Date : 2006:03:08 15:51:51-05:00EXIF Metadata provided by EXIF.tools