Aleph America XC-002-00 Outdoor Intrusion Detection Unit (FDS) User Manual C XC 1xt Info XC1 XT New rede

Aleph America Corporation Outdoor Intrusion Detection Unit (FDS) C XC 1xt Info XC1 XT New rede

Users Manual

Download: Aleph America XC-002-00 Outdoor Intrusion Detection Unit (FDS) User Manual C  XC 1xt  Info XC1 XT New rede
Mirror Download [FCC.gov]Aleph America XC-002-00 Outdoor Intrusion Detection Unit (FDS) User Manual C  XC 1xt  Info XC1 XT New rede
Document ID1183441
Application ID+klHopYPNkqJw81ZxDx1/g==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.81kB (97660 bits)
Date Submitted2009-10-14 00:00:00
Date Available2009-10-14 00:00:00
Creation Date2009-10-08 20:15:43
Producing SoftwaredoPDF Ver 6.2 Build 301 (Windows Vista x32)
Document Lastmod0000-00-00 00:00:00
Document TitleC:\XC-1xt Info\XC1-XT New rede
Document CreatorC:\XC-1xt Info\XC1-XT New rede
Document Author: saguilar

XC-1XT SERIES
Outdoor Dual Technology Intrusion Detector
40FT L X 56 W (12m x 17m)
Description: XC-1XT provides unsurpassed wide area unsecured outdoor instruion detection.
Combining Microwave & PIR detection technologies the XC-1XT ensures excellent coverage without
nuisance alarms. Dual outputs allow the use of a single detector for annunciation and security,
or allow multiple functioning via different control device assignments.
Installation:
For best results install the XC-1XT at a mounting height between 6.6 ft.(2.0m) and 8.2 ft. (2.5m). Mount the unit so it is
looking into an area free of obstructions, do not mount the unit so it is looking directly at heating or cooling sources. Avoid
viewing operating machinery or objects which have the potential for movement. Do not aim unit so it is looking at public
road / pathways.
Wire the XC-1XT to the control panel device using 18 to 24 AWG standard non-shielded wire, do not run wiring parallel to
AC wiring. Wiring should be in accordance with NEC, NFPA 70 for North America.
Prior to re-attaching front cover to unit; Set PIR sensitivity, PulseCount, LED Enable, Detection mode, and 50/60Hz
Flourescent Light immunity setting (Selectable Switch 1,2,3,4,5, and 6) as desired.
If the detector is viewing a narrow area, a PC setting of 4 should be avoided, as the small area may not allow enough
movement to detect intruders. A PC of “4” is best suited for a wide open detection area. For High Security applications set
PIR Sensitivity to “High Sensitivity” =(SW1 & 2 = 120% or 100%), this allows for a quicker detection at the edge of the
detection area. Animal Immunity characteristics are not available when a “High Sensitivity” setting is configured on the
XC-1XT. Animal Immunity function is enabled by placing PIR Sensitivity at 60%. Use Microwave Sensitivity adjustment
potentiometer to adjust Microwave sensitivity (Preset @ 50%). A properly adjusted MW will detect crossing movement just
inside the protected area but not outside of the PIR coverage area.
SW-5 allow for the selection of Dual-Technology (MW & PIR) or PIR only detection modes. A PIR only detection mode is
useful when there is operating machinery or exposed fans always active within the protected area.
If the installation site is subject to severe vibrations (via close proximity to railroad tracks and /or large truck movement),
ensure that the mounting point is on a riged surface. In some situations it may be necessary to place a piece of plywood
between the mounting surface and the XC-1XT detector to buffer wall movement.
Walk-Test:
Once installation and initial setup is complete, perform a full walk test to insure that the detection parameters are met, if
required make control adjustments to fine tune detection characteristics. In order to insure detection quality, the XC-1XT
should be tested routinely, with no more than a one year period between tests.
Control Layout and Configuration:
Function Select Switch
uW Module Do not Touch
LED Indicators
Green = PIR
Red = Alarm
Amber = MW
SW-1 & 2 :PIR Sensitivity
120%
OFF
SW-1
SW-2
SW-3
SW-4
SW-5
SW-6
100%
80%
60%
ON
SW-3 Pulse Count
3 off - PC2
3 on - PC4
PIR Detector Do not Touch
Microwave Sensitivity
Adjustment
SW-4 LED Enable
4 off - LED’s Enabled
4 on - LED’s Disabled
SW-5 Detection Mode
5 off - Dual (MW & PIR)
5 on - PIR Only
SW-6 50/60 Hz
6 off - 60Hz
6 on - 50Hz
MIN.
MAX.
The Sensitivity Adjustment
allows for MW coverage to be
fine set to the protected area.
Preset = 50%
Max. = increases sensitivity
Tamper Switch
Min. = decreases sensitivity
Terminal Configuration
TAMPER
ALARM 1
ALARM 2
SPARE
POWER
Switch ON
Switch OFF
NC NO C
NC NO
DetectionPattern Ilustration(Standard Lens)
1.5
3.0 4.5
6.0
7.5
9.0 10.5 12.0
28
25
8.5
7.5
20
6.0
15
4.5
10
3.0
1.5
1.5
10
3.0
15
4.5
20
6.0
25
28
7.5
8.5
10
15
20
25
30
35
.75
1.5
3.0
4.5
12.0
= Six Mounting Points available.
Cause
Remedy
No or low input power.
Input power polarity reversed.
Apply proper input voltage.
Correct wiring polarity.
Alarm LED does not light up.
SW-4 is set to ON/ Disabled
Detedtion Sensitivity setting incorrect.
Set SW-4 to “OFF”.
Set SW-1 &2 and/or MW range
adjustment to match desired area.
Set SW-3 to correct PC.
Pulse Count setting incorrect for area.
Alarm LED/ Relay Triggers W/O
movement in the detection area
Incorrect Sensor mounting height.
Unsecured environment animals/rodents
in protected area.
Machinery operating in sensor view
Direct sunlight/headlight in sensor view.
LED indicates alarm, no alarm output
When installing this unit in a corner mount
application, install screws into one side of the
case. Installing screws into both sides of the
case when walls are uneven causes the plastic
case to become distorted thus water can be
allowed entry into the unit.
Increase/Decrease mounting height.
Block animal/rodent access.
Remove the hazard / Re-aim sensor so
it is not viewing hazard/machinery.
Switch detection mode to “Dual”, add
curtain/shade to block light sources.
Severe vibration at mounting wall.
Buffer mounting with plywood. Relocate XC-1XT
mounting position.
Incorrect wiring at alarm output terminals.
Open circuit in wiring between detector &
control panel.
Lightning damage to detector and/or control
panel.
Correct wiring fault.
Replace/ Repair wiring.
Exterior Wiring Channel
After wiring, install the foam wiring access bug
guard to prevent ingress of dust and insects.
Replace damaged equipment.
MODEL : XC-1XT
FCC ID: DNHXC-002-00
Aleph hereby declares that the XC-1XTEU and XC-1XTUK Intrusion Detector is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may
be consulted at http://www.alepheurope.com/
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio / TV technician for help.
The user should not modify or change this equipment without written approval from ALEPH.
Modification could void authority to use this equipment.
{European info here}
Testing and Maintenance:
- INSPECTION: An inspection of this unit should be made periodically, consisting of, but not
limited to all mounting, wiring and the condition of the interior components.
- CLEANING: Clean the external plastic parts of this unit with a soft, damp cloth.
- TESTING: This unit should be tested routinely for proper operation. At a minimum,
operation should be fully checked yearly.
- NOTES: This unit is designed to be incorporated into an overall alarm system. As it is part
of the system ALEPH cannot assume responsibility for theft or damage if the system fails to
operate.
Contact Aleph
Specifications
9.5-16 VDC, 12VDC Nominal
Alarm Output
Current Draw
35 mA Max.
Tamper Output
Warm Up Period
<50 Seconds
Operating Temperature -4°F to +122°F (-20°C to +50°C)
Alarm Period
LED Indicators
2.4 Seconds
Red = Alarm
Amber = Microwave
Green = PIR
6.2 oz. (176 g)
10.525GHz (US and EU)
10.687GHz (UK)
Humidity Limits
95% Max. Non-condensing
Dimensions (H x W x D) 6.3in.(L) X 2.76in.(W) X 1.73in.(D)
(160mm x 70mm x 43.9mm)
PIR Detector Type
Range Stand. Lens
Range Optional Lens
(Curtain)
Dual Element
40ft L x 56ft W
80ft L x 8ft W
Pulse Count
2 or 4 Step Catch
MW Range adjustment
Four Adjustable Settings
60%, 80%, 100% and 120%
Adjustable via a Potentiometer
IP Rating
IP54
Mounting Height
6.6 ft (2.0m) to 8.2ft (2.5m)
Two Form C
(NC/NO)outputs
30 VDC/350mA Max.
NC/ 30VDC/500mA
In a continuing effort to improve product performance, specifications
and design characteristics may be changed without prior notice.
U.S. & International Patents Pending
MODEL : XC-1XTUK
MODEL : XC-1XTEU
Power Requirements
P/N 9-900-009-00 Rev. A
10.5
Rear Cover (Interior View, PCB removed)
Trouble
PIR Sensitivity
9.0
40
Unit does not power up.
Weight
MW Detector Type
7.5
Troubleshooting:
FCC Information:
6.0
8.5
Nippon Aleph Corporation
-Security Products Headquarters1-28-52, Komaoka, Tsurimi-ku,
Yokohama-shi, Kanagawa-ken
JAPAN, 230-0071
Tel: +81 045-575-4290 / Fax: +81 045-580-1676
E-mail: security@po.nippon-aleph.co.jp
WEB: http://www.nippon-aleph.co.jp
Aleph America Corporation
4700 Aircenter Cir, Reno, NV, 89502
USA
Tel: 775 827 8000 / Fax: 775 827 8044
E-mail: info@aleph-usa.com
WEB: http://www.aleph-usa.com
Aleph Europe Ltd.
1 Newton Close, Park Farm Industrial Estate
Wellingborough, Northamptonshire, NN8 6UW
England
Tel: 044 193 367 9600 / Fax: 044 193 340 1165
E-mail: info@alepheurope.com
WEB: http://www.alepheurope.com


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 3
Page Layout                     : OneColumn
Page Mode                       : UseNone
Title                           : C:\XC-1xt  Info\XC1-XT New rede
Author                          : saguilar
Creator                         : C:\XC-1xt  Info\XC1-XT New rede
Producer                        : doPDF   Ver 6.2 Build 301 (Windows Vista  x32)
Create Date                     : 2009:10:08 20:15:43
EXIF Metadata provided by EXIF.tools
FCC ID Filing: DNHXC-002-00

Navigation menu