Allied Telesis Switch At X510 28Gpx Users Manual Series Installation Guide For Stand Alone Switches
AT-X510-28GTX to the manual a4015afc-0755-481c-bacc-4274fd79603e
2015-02-02
: Allied-Telesis Allied-Telesis-Allied-Telesis-Switch-At-X510-28Gpx-Users-Manual-414318 allied-telesis-allied-telesis-switch-at-x510-28gpx-users-manual-414318 allied-telesis pdf
Open the PDF directly: View PDF .
Page Count: 90
Download | |
Open PDF In Browser | View PDF |
x510 Series Gigabit Ethernet Switches AT-x510-28GTX AT-x510-28GPX AT-x510-28GSX AT-x510-52GTX AT-x510-52GPX Installation Guide for Stand-alone Switches 613-001764 Rev. B Copyright 2013 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility of such damages. Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment. Industry Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. RFI Emissions: FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK, CE Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EMC (Immunity): EN55024 Electrical Safety: EN60950-1 (TUV), UL 60950-1 (CULUS) Laser Safety EN60825 3 Translated Safety Statements Important: Safety statements that have the symbol are translated into multiple languages in the Translated Safety Statements document at www.alliedtelesis.com/support. 4 Contents Preface .............................................................................................................................................................................. 11 Document Conventions .......................................................................................................................................................12 Contacting Allied Telesis .....................................................................................................................................................13 Chapter 1: Overview ........................................................................................................................................................ 15 Features ..............................................................................................................................................................................16 x510 Models .................................................................................................................................................................16 10/100/1000 Mbps Twisted Pair Ports .........................................................................................................................16 Power Over Ethernet ....................................................................................................................................................16 SFP Slots .....................................................................................................................................................................16 SFP+ Slots ...................................................................................................................................................................17 Stacking Slots...............................................................................................................................................................17 LEDs.............................................................................................................................................................................18 Installation Options .......................................................................................................................................................18 MAC Address Table .....................................................................................................................................................18 Management Software and Interfaces .........................................................................................................................18 Management Methods..................................................................................................................................................18 Front and Back Panels ........................................................................................................................................................19 Management Panel .............................................................................................................................................................22 10/100/1000Base-T Twisted Pair Ports ...............................................................................................................................23 Speed ...........................................................................................................................................................................23 Duplex Mode ................................................................................................................................................................23 Wiring Configuration .....................................................................................................................................................23 Maximum Distance .......................................................................................................................................................24 Cable Requirements.....................................................................................................................................................24 Port Pinouts ..................................................................................................................................................................24 Power Over Ethernet ...........................................................................................................................................................25 PoE Standards .............................................................................................................................................................25 Powered Device Classes .............................................................................................................................................25 Cable Requirements.....................................................................................................................................................26 Power Budget ...............................................................................................................................................................27 Port Prioritization ..........................................................................................................................................................28 Wiring Implementation..................................................................................................................................................29 SFP+ Slots...........................................................................................................................................................................30 Stacking SFP+ Slots............................................................................................................................................................31 eco-friendly Button...............................................................................................................................................................32 LEDs ....................................................................................................................................................................................33 LEDs for the Twisted Pair Ports ...................................................................................................................................33 LEDs for the SFP Slots ................................................................................................................................................36 LEDs for the SFP+ Slots ..............................................................................................................................................37 LEDs for the Stacking Slots..........................................................................................................................................38 Switch ID LED ..............................................................................................................................................................38 USB Port..............................................................................................................................................................................41 Console Port ........................................................................................................................................................................42 Power Supplies....................................................................................................................................................................43 Chapter 2: Beginning the Installation ............................................................................................................................ 45 Reviewing Safety Precautions .............................................................................................................................................46 Choosing a Site for the Switch ............................................................................................................................................50 Unpacking the Switch ..........................................................................................................................................................51 5 Contents Chapter 3: Installing the Switch on a Table or in an Equipment Rack ....................................................................... 53 Installing the Switch on a Table or Desktop........................................................................................................................ 54 Installing the Switch in an Equipment Rack ........................................................................................................................ 55 Chapter 4: Cabling the Networking Ports ...................................................................................................................... 59 Cabling the Twisted Pair Ports............................................................................................................................................ 60 Installing SFP and SFP+ Transceivers ............................................................................................................................... 62 Installing SFP Modules in the AT-x510-28GSX Switch ............................................................................................... 63 Installing SFP and SFP+ Modules............................................................................................................................... 66 Chapter 5: Powering On the Switch ............................................................................................................................... 69 Powering On the Switch...................................................................................................................................................... 70 Monitoring the Initialization Processes ........................................................................................................................ 71 Configuring the Switch for Stand-alone Operations............................................................................................................ 74 Starting a Local Management Session ........................................................................................................................ 74 Disabling VCStack ....................................................................................................................................................... 76 Confirming the Status of the VCStack Feature............................................................................................................ 78 Specifying Ports in the Command Line Interface for Stand-alone Switches....................................................................... 80 Chapter 6: Troubleshooting ............................................................................................................................................ 81 Appendix A: Technical Specifications ........................................................................................................................... 85 Physical Specifications ....................................................................................................................................................... 85 Environmental Specifications.............................................................................................................................................. 86 Power Specifications........................................................................................................................................................... 86 Certifications ....................................................................................................................................................................... 87 RJ-45 Twisted Pair Port Pinouts ......................................................................................................................................... 87 RJ-45 Style Serial Console Port Pinouts ............................................................................................................................ 88 6 Figures Figure 1: Front Panels of the AT-x510-28GTX and AT-x510-28GPX Switches ...................................................................19 Figure 2: Front Panels of the AT-x510-28GSX, AT-x510-52GTX, and AT-x510-52GPX Switches......................................20 Figure 3: Back Panel of the AT-x510-28GTX, AT-x510-52GTX, and AT-x510-28GSX Switches ........................................21 Figure 4: Back Panel of the AT-x510-28GPX and AT-x510-52GPX Switches .....................................................................21 Figure 5: x510 Series Management Panel ...........................................................................................................................22 Figure 6: LEDs for the 10/100/1000Base-T Ports on the AT-x510-28GTX and AT-x510-52GTX Switches.........................33 Figure 7: LEDs for the 10/100/1000Base-T Ports on the AT-x510-28GPX and AT-x510-52GPX Switches ........................35 Figure 8: SFP Slot LEDs on the AT-x510-28GSX Switch.....................................................................................................36 Figure 9: SFP+ Slot LEDs ....................................................................................................................................................37 Figure 10: Switch ID LED .....................................................................................................................................................39 Figure 11: Switch ID LED .....................................................................................................................................................39 Figure 12: Switch ID LEDs in the Low Power Mode .............................................................................................................40 Figure 13: Components of the x510 Series Switches...........................................................................................................51 Figure 14: Turning the Switch Upside Down ........................................................................................................................55 Figure 15: Removing the Rubber Feet .................................................................................................................................55 Figure 16: Attaching the Equipment Rack Brackets .............................................................................................................56 Figure 17: Attaching the Equipment Rack Brackets (Continued) .........................................................................................57 Figure 18: Mounting the Switch in an Equipment Rack ........................................................................................................57 Figure 19: Removing the Dust Plug from an SFP Slot .........................................................................................................63 Figure 20: Installing an SFP Transceiver..............................................................................................................................64 Figure 21: Removing the Dust Cover from an SFP Transceiver ..........................................................................................64 Figure 22: Positioning the SFP Handle in the Upright Position ............................................................................................65 Figure 23: Connecting a Fiber Optic Cable to an SFP Transceiver......................................................................................65 Figure 24: Removing the Dust Plug from an SFP+ Slot .......................................................................................................66 Figure 25: Installing an SFP or SFP+ Transceiver ...............................................................................................................67 Figure 26: Removing the Dust Cover from an SFP or SFP+ Transceiver ............................................................................67 Figure 27: Positioning the SFP or SFP+ Handle in the Upright Position ..............................................................................68 Figure 28: Connecting a Fiber Optic Cable to an SFP or SFP+ Transceiver .......................................................................68 Figure 29: Plugging in the AC Power Cord...........................................................................................................................70 Figure 30: Switch Initialization Messages.............................................................................................................................71 Figure 31: Switch Initialization Messages (Continued) .........................................................................................................72 Figure 32: Switch Initialization Messages (Continued) .........................................................................................................73 Figure 33: Connecting the Management Cable to the Console Port ....................................................................................75 Figure 34: User Exec Mode Prompt .....................................................................................................................................76 Figure 35: SHOW STACK Command...................................................................................................................................76 Figure 36: Moving to the Global Configuration Mode ...........................................................................................................77 Figure 37: Confirmation Prompt for the NO STACK ENABLE Command ............................................................................77 Figure 38: Returning to the Privileged Exec Mode ...............................................................................................................77 Figure 39: Saving the Changes with the WRITE Command.................................................................................................78 Figure 40: Status of a Stacking Slot When VCStack is Disabled .........................................................................................79 Figure 41: Status of a Stacking Slot When VCStack is Enabled ..........................................................................................79 Figure 42: PORT Parameter in the Command Line Interface...............................................................................................80 Figure 43: RJ-45 Socket Pin Layout (Front View) ................................................................................................................87 7 Figures 8 Tables Table 1: Twisted Pair Cable for the 10/100/1000Base-T Ports ...........................................................................................24 Table 2: IEEE Powered Device Classes ..............................................................................................................................26 Table 3: Twisted Pair Cable Requirements for the 10/100/1000Base-T Ports at 10 or 100Mbps .......................................26 Table 4: Twisted Pair Cable Requirements for the 10/100/1000Base-T Ports at 1000Mbps ..............................................27 Table 5: Stacking Transceivers ...........................................................................................................................................31 Table 6: LEDs on the 10/100/1000Base-T Ports on the AT-x510-28GTX and AT-x510-52GTX Switches .........................34 Table 7: LEDs on the 10/100/1000Base-T Ports on the AT-x510-28GPX and AT-x510-52GPX Switches .........................35 Table 8: SFP Slot LEDs on the AT-x510-28GSX Switch .....................................................................................................37 Table 9: SFP+ Slot LEDs .....................................................................................................................................................38 Table 10: Stacking Slot LEDs ..............................................................................................................................................38 Table 11: Product Dimensions .............................................................................................................................................85 Table 12: Product Weights ..................................................................................................................................................85 Table 13: Ventilation Requirements .....................................................................................................................................85 Table 14: Environmental Specifications ...............................................................................................................................86 Table 15: Maximum Power Consumption ............................................................................................................................86 Table 16: Input Voltages ......................................................................................................................................................86 Table 17: Product Certifications ...........................................................................................................................................87 Table 18: Pin Signals for 10 and 100 Mbps .........................................................................................................................87 Table 19: Pin Signals for 1000 Mbps ...................................................................................................................................88 Table 20: RJ-45 Style Serial Console Port Pin Signals .......................................................................................................88 9 Tables 10 Preface This guide contains the installation instructions for the x510 Series of Layer 2+ and Basic Layer 3, Gigabit Ethernet switches. This preface contains the following sections: “Document Conventions” on page 12 “Contacting Allied Telesis” on page 13 Note This guide explains how to install the switches as stand-alone units. For instructions on how to install them in a stack configuration with Virtual Chassis Stacking (VCStack™), refer to the x510 Series Installation Guide for Virtual Chassis Stacking. 11 Preface Document Conventions This document uses the following conventions: Note Notes provide additional information. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. 12 x510 Series Installation Guide for Stand-alone Switches Contacting Allied Telesis If you need assistance with this product, you may contact Allied Telesis technical support by going to the Support & Services section of the Allied Telesis web site at www.alliedtelesis.com/support. You can find links for the following services on this page: 24/7 Online Support — Enter our interactive support center to search for answers to your product questions in our knowledge database, to check support tickets, to learn about RMAs, and to contact Allied Telesis technical experts. USA and EMEA phone support — Select the phone number that best fits your location and customer type. Hardware warranty information — Learn about Allied Telesis warranties and register your product online. Replacement Services — Submit a Return Merchandise Authorization (RMA) request via our interactive support center. Documentation — View the most recent installation and user guides, software release notes, white papers, and data sheets for your products. Software Downloads — Download the latest software releases for your managed products. For sales or corporate information, go to www.alliedtelesis.com/ purchase and select your region. 13 Preface 14 Chapter 1 Overview This chapter contains the following sections: “Features” on page 16 “Front and Back Panels” on page 19 “Management Panel” on page 22 “10/100/1000Base-T Twisted Pair Ports” on page 23 “Power Over Ethernet” on page 25 “SFP+ Slots” on page 30 “Stacking SFP+ Slots” on page 31 “eco-friendly Button” on page 32 “LEDs” on page 33 “USB Port” on page 41 “Console Port” on page 42 “Power Supplies” on page 43 Note This guide explains how to install the switches as stand-alone units. For instructions on how to install them in a stack configuration with Virtual Chassis Stacking (VCStack™), refer to the x510 Series Installation Guide for Virtual Chassis Stacking. 15 Chapter 1: Overview Features Here are the switches and their features: x510 Models 10/100/1000 Mbps Twisted Pair Ports Power Over Ethernet SFP Slots Here are the x510 Series switches: AT-x510-28GTX AT-x510-28GPX AT-x510-28GPX AT-x510-52GTX AT-x510-52GPX Here are the basic features of the 10/100/1000 Mbps twisted pair ports: 24 or 48 ports per switch 10Base-T, 100Base-TX, and 1000Base-T compliant IEEE 802.3u Auto-Negotiation compliant Auto-MDI/MDIX 100 meters (328 feet) maximum operating distance IEEE 802.3x flow control in 10/100Base-TX full-duplex mode IEEE 802.3x backpressure in 10/100Base-TX half-duplex mode IEEE 802.3ab 1000Base-T Jumbo frames up to 13KB RJ-45 connectors Here are the basic features of Power over Ethernet (PoE) on the twisted pair ports on the AT-x510-28GPX and AT-x510-52GPX Switches: Supported on ports 1 to 24 on the AT-x510-28GPX Switch and ports 1 to 48 on the AT-x510-52GPX Switch Supports PoE (15.4 watts maximum) and PoE+ (30 watts maximum) powered devices Supports powered device classes 0 to 4 Maximum power budget of 370 watts Port prioritization Mode A wiring Here are the basic features of the SFP slots on the AT-x510-28GSX Switch: 16 Supports 100Base-FX and 1000Base-SX/LX SFP transceivers x510 Series Installation Guide for Stand-alone Switches Supports single-port BiDi 1000Base-LX SFP transceivers Supports 1000Base-ZX SFP transceivers Supports 10/100/1000Base-T twisted pair transceivers Note SFP transceivers must be purchased separately. For a list of supported transceivers, contact your Allied Telesis distributor or reseller. SFP+ Slots Here are the basic features of the four SFP+ slots on the switches: Supports 10Gbps, 10GBase-SR/LR fiber optic transceivers Supports 10Gbps AT-SP10TW direct connect twinax cables with SFP+ transceiver-style connectors Supports 1000Base-SX/LX SFP transceivers Supports single-port BiDi 1000Base-LX SFP transceivers Supports 1000Base-ZX SFP transceivers Note The SFP+ slots do not support 100Mbps 100Base-FX transceivers. Note SFP and SFP+ transceivers must be purchased separately. For a list of supported transceivers, contact your Allied Telesis distributor or reseller. Note SFP+ slots 27 and 28 on the 28-port switches and slots 51 and 52 on the 52-port switches are initially configured as stacking slots for the VCStack feature. If you intend to use the switch as a stand-alone unit, you must disable the VCStack feature before you can use the slots with standard SFP or SFP+ transceivers. The configuration instructions are provided later in this guide, in “Configuring the Switch for Stand-alone Operations” on page 74. Stacking Slots Two of the SFP+ slots can be used to create a VCStack of up to four switches. The slots support these stacking transceivers when the switch is in the stacking mode: AT-StackXS/1.0 Twisted Pair Transceiver - 1 meter AT-StackOP/0.3 Fiber Optic Transceiver - 300 meters AT-StackOP/9.0 Fiber Optic Transceiver - 9 kilometers 17 Chapter 1: Overview LEDs Installation Options MAC Address Table Management Software and Interfaces Management Methods 18 Here are the port LEDs: Link/activity and duplex mode LEDs for the twisted pair ports on non-PoE switches Link/activity and PoE status LEDs for the twisted pair ports on PoE switches Link/activity LEDs for SFP and SFP+ slots Stack ID number LED eco-friendly button turns off the LEDs to conserve electricity Here are the installation options for the switches: 19-inch equipment rack Desk or tabletop Here are the basic features of the MAC address tables of the switches: Storage capacity of 16,000 dynamic MAC address entries Storage capacity of 256 static MAC address entries Automatic learning and aging Here are the management software and interfaces: AlliedWare Plus Management Software Command line interface Web browser interface Here are the methods for managing the switches: Local management through the Console port Remote Telnet and Secure Shell management Remote HTTP and HTTPS web browser management SNMPv1, v2c, and v3 x510 Series Installation Guide for Stand-alone Switches Front and Back Panels The front panels of the x510 Series switches are shown in Figure 1 and Figure 2 on page 20. AT-x510-28GTX 10/100/1000Base-T Ports Management Panel SFP+ Slots SFP+ or Stacking Slots AT-x510-28GPX Management Panel 10/100/1000Base-T Ports with PoE SFP+ Slots SFP+ or Stacking Slots Figure 1. Front Panels of the AT-x510-28GTX and AT-x510-28GPX Switches 19 Chapter 1: Overview AT-x510-28GSX 10/100/1000Base-T and 100/1000Base-FX Transceiver Slots Management Panel SFP+ Slots SFP+ or Stacking Slots AT-x510-52GTX Management Panel 10/100/1000Base-T Ports SFP+ Slots SFP+ or Stacking Slots AT-x510-52GPX 10/100/1000Base-T Ports with PoE Management Panel SFP+ Slots SFP+ or Stacking Slots Figure 2. Front Panels of the AT-x510-28GSX, AT-x510-52GTX, and ATx510-52GPX Switches 20 x510 Series Installation Guide for Stand-alone Switches Figure 3 shows the back panel of the AT-x510-28GTX, AT-x510-52GTX, and AT-x510-28GSX Switches. AC Power Connector (Power Supply 2) AC Power Connector (Power Supply 1) Figure 3. Back Panel of the AT-x510-28GTX, AT-x510-52GTX, and ATx510-28GSX Switches Figure 4 shows the back panel of the AT-x510-28GPX and AT-x51052GPX Switches. AC Power Connector (Power Supply 2) AC Power Connector (Power Supply 1) Figure 4. Back Panel of the AT-x510-28GPX and AT-x510-52GPX Switches 21 Chapter 1: Overview Management Panel Figure 5 identifies the components in the management panels on the x510 Series switches. Console Management Port Switch ID LED eco-friendly Button USB Port Figure 5. x510 Series Management Panel 22 x510 Series Installation Guide for Stand-alone Switches 10/100/1000Base-T Twisted Pair Ports The switches have 24 or 48 10/100/1000Base-T ports. Speed The ports can operate at 10, 100, or 1000 Mbps. The speeds may be set manually using the management software or automatically with AutoNegotiation (IEEE 802.3u), the default setting. Note The ports must be set to Auto-Negotiation to function at 1000 Mbps and are not compatible with devices that are not IEEE 802.3u compliant. Duplex Mode The twisted pair ports can operate in either half- or full-duplex mode. The duplex mode of a port, like port speed, may be set manually using the management software or automatically with Auto-Negotiation (IEEE 802.3u), the default setting. The speed and duplex mode settings of a port may be set independently of each other. For example, a port may be configured such that its speed is set manually while its duplex mode is established through AutoNegotiation. Note A switch port should not use Auto-Negotiation to set its duplex mode if it is connected to a network device that does not support AutoNegotiation for 10 or 100 Mbps operation and has a fixed duplex mode of full-duplex. Otherwise, a duplex-mode mismatch may occur in which a switch port and a network device operate at different duplex modes. The duplex modes of switch ports that are connected to network devices that do not support Auto-Negotiation should be set manually through the management software. Wiring Configuration The wiring configuration of a port operating at 10 or 100 Mbps can be MDI or MDI-X. The wiring configurations of a switch port and a network device connected with straight-through twisted pair cabling have to be opposite, such that one device is using MDI and the other MDI-X. For instance, a switch port has to be set to MDI-X if it is connected to a network device set to MDI. You may set the wiring configurations of the ports manually or let the switch configure them automatically with auto-MDI/MDI-X (IEEE 802.3abcompliant). This feature enables the switch to automatically negotiate with network devices to establish their proper settings. 23 Chapter 1: Overview The MDI and MDI-X settings do not apply when ports are operating at 1000 Mbps. Maximum Distance Cable Requirements The ports have a maximum operating distance of 100 meters (328 feet). The cable requirements of the ports are given in Table 1. Table 1. Twisted Pair Cable for the 10/100/1000Base-T Ports Cable Type Standard TIA/EIA 568-Bcompliant Category 3 shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz. 10Mbps 100Mbps 1000Mbps Yes Yes No Standard TIA/EIA 568-AYes compliant Category 5 or TIA/ EIA 568-B-compliant Enhanced Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz. Yes Yes Standard TIA/EIA 568-Bcompliant Category 6 or 6a shielded cabling. Yes Yes Yes Note For the cable requirements for the ports on the AT-x510-28GPX and AT-x510-52GPX Switches for PoE devices, refer to Table 3 on page 26. Port Pinouts 24 Refer to Table 18 on page 87 and Table 19 on page 88 for the port pinouts of the 10/100/1000Base-T twisted pair ports. x510 Series Installation Guide for Stand-alone Switches Power Over Ethernet The AT-x510-28GPX and AT-x510-52GPX Switches feature Power over Ethernet (PoE) on the 10/100/1000Base-T ports. PoE is used to supply power to network devices over the same twisted pair cables that carry the network traffic. The main advantage of PoE is that it can make it easier to install a network. The selection of a location for a network device is often limited by whether there is a power source nearby. This often limits equipment placement or requires the added time and cost of having additional electrical sources installed. But with PoE, you can install PoE-compatible devices wherever they are needed without having to worry about whether there are power sources nearby. A device that provides PoE to other network devices is referred to as power sourcing equipment (PSE). The AT-x510-28GPX and AT-x51052GPX Switches act as PSE units by adding DC power to the network cable, thus functioning as a central power source for other network devices. Devices that receive their power from a PSE are called powered devices (PD). Examples include wireless access points, IP telephones, webcams, and even other Ethernet switches. The switch automatically determines whether or not a device connected to a port is a powered device. Ports that are connected to network nodes that are not powered devices (that is, devices that receive their power from another power source) function as regular Ethernet ports, without PoE. The PoE feature remains activated on the ports but no power is delivered to the devices. PoE Standards Powered Device Classes The AT-x510-28GPX and AT-x510-52GPX Switches support these PoE standards: PoE (IEEE 802.3af): This standard provides up to 15.4 watts at the switch port to support powered devices that require up to 12.95 watts. PoE+ (IEEE 802.3at): This standard provides up to 30.0 watts at the switch port to support powered devices that require up to 25.5 watts. Powered devices are grouped into the five classes listed in Table 2 on page 26. The classes are based on the amount of power the devices require. The switches support all five classes. 25 Chapter 1: Overview Table 2. IEEE Powered Device Classes Maximum Power Output from a Switch Port Class Cable Requirements PD Power Range 0 15.4W 0.44W to 12.95W 1 4.0W 0.44W to 3.84W 2 7.0W 3.84W to 6.49W 3 15.4W 6.49W to 12.95W 4 30.0W 12.95W to 25.5W The cable requirements for ports operating at 10 or 100Mbps are given in Table 3. Table 3. Twisted Pair Cable Requirements for the 10/100/1000Base-T Ports at 10 or 100Mbps 10Mbps Cable Type 26 NonPoE PoE 100Mbps PoE+ NonPoE PoE PoE+ Standard TIA/EIA 568-Bcompliant Category 3 shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz. Yes Yes No Yes Yes No Standard TIA/EIA 568-Acompliant Category 5 shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz. Yes Yes No Yes Yes No Standard TIA/EIA 568-Bcompliant Enhanced Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz. Yes Yes Yes Yes Yes Yes Standard TIA/EIA 568-Bcompliant Category 6 or 6a shielded cabling. Yes Yes Yes Yes Yes Yes x510 Series Installation Guide for Stand-alone Switches The cable requirements for ports operating at 1000Mbps are given in Table 4. Table 4. Twisted Pair Cable Requirements for the 10/100/1000Base-T Ports at 1000Mbps 1000Mbps Cable Type Power Budget NonPoE PoE PoE+ Standard TIA/EIA 568-B-compliant Category 3 shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz. No No No Standard TIA/EIA 568-A-compliant Category 5 shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz. Yes Yes No Standard TIA/EIA 568-B-compliant Yes Enhanced Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz. Yes Yes Standard TIA/EIA 568-B-compliant Category 6 or 6a shielded cabling. Yes Yes Yes The AT-x510-28GPX and AT-x510-52GPX Switches have a power budget of 370 watts. This is the maximum amount of power the switches can provide at one time to the powered devices. The AT-x510-28GPX and AT-x510-52GPX Switches have two power supplies. Each power supply is responsible for providing 185 watts, or half, of the power budget. Both power supplies must be connected to AC power sources for the switch to provide the full 370 watts. The power budget is reduced to 185 watts if only one power supply is connected to a power source. The power requirements of the PoE devices determine the maximum number of devices the switch can support at one time. So long as the total power requirements of the powered devices is less than the power budget of the switch, the switch can supply power to all the devices. But if the total power requirements exceed the power budget, the switch denies power to one or more ports using a mechanism referred to as port prioritization. To determine whether the power requirements of the PoE devices you plan to connect to the switch exceed its power budget, refer to their documentation for their power requirements and add the requirements together. The switch should be able to power all of the devices 27 Chapter 1: Overview simultaneously as long as the total is below its power budget. If the total exceeds the available power budget, you should consider reducing the number of PoE devices so that all of the devices receive power. Otherwise, the switch powers a subset of the devices, based on port prioritization. The switch can handle different power requirements on different ports. This enables you to connect different classes of PoE equipment to the ports on the switch. Port Prioritization If the power requirements of the powered devices exceed the switch’s power budget, the switch denies power to some ports based on a system called port prioritization. You may use this mechanism to ensure that powered devices critical to the operations of your network are given preferential treatment by the switch in the distribution of power should the demands of the devices exceed the available capacity. There are three priority levels: Critical High Low Ports set to the Critical level, the highest priority level, are guaranteed power before any of the ports assigned to the other two priority levels. Ports assigned to the other priority levels receive power only if all the Critical ports are receiving power. Ports that are connected to your most critical powered devices should be assigned to this level. If there is not enough power to support all the ports set to the Critical priority level, power is provided to the ports based on port number, in ascending order. The High level is the second highest level. Ports set to this level receive power only if all the ports set to the Critical level are already receiving power. If there is not enough power to support all of the ports set to the High priority level, power is provided to the ports based on port number, in ascending order. The lowest priority level is Low. This is the default setting. Ports set to this level only receive power if all of the ports assigned to the other two levels are already receiving power. As with the other levels, if there is not enough power to support all of the ports set to the Low priority level, power is provided to the ports based on port number, in ascending order. Power allocation is dynamic. Ports supplying power to powered devices may cease power transmission if the switch’s power budget is at maximum usage and new powered devices, connected to ports with higher priorities, become active. You can use port prioritization on dual power supply PoE switches to protect your important networking devices from loss of power should one 28 x510 Series Installation Guide for Stand-alone Switches of the power supplies fail or lose power. If you limit the power requirements of the critical devices connected to a switch to less than 185 watts, the PoE power provided by a single power supply, a switch will have sufficient power to support the critical devices even if it has only one functional power supply. Wiring Implementation The IEEE 802.3af standard defines two methods for the delivery of DC power over twisted pair cable by a PSE, such as the switch, to PDs. These methods, known as modes A and B, identify the wires within the cable that carry the DC power from the PSE to a PD. Twisted pair cabling typically consists of eight wires. With 10Base-T and 100Base-TX devices, the wires connected to pins 1, 2, 3, and 6 on the RJ45 connectors carry the network traffic while the wires connected to pins 4, 5, 7, and 8 are unused. With 1000Base-T devices, all eight wires are used to carry network data. It takes four wires to deliver DC power to a PD. With Mode A, the power is delivered on pins 1, 2, 3, and 6. These are the same pins in 10Base-T and 100Base-TX devices that carry the network data. With mode B, the power is provided over the spare wires. The ports on the AT-x510-28GPX and AT-x510-52GPX Switches deliver the power using pins 1, 2, 3, and 6, which corresponds to mode A in the IEEE 802.3af standard. Powered devices that comply with the IEEE 802.3af standard are required to support both power delivery methods. Legacy devices that do not comply with the standard will work with the switch if they are powered on pins 1, 2, 3, and 6. 29 Chapter 1: Overview SFP+ Slots The switches have four SFP+ slots that support the following types of SFP 1000Mbps and SFP+ 10Gbps transceivers: 1000Base-SX/LX SFP transceivers Single-port BiDi 1000Base-LX SFP transceivers 1000Base-ZX SFP transceivers 10Gbps, 10GBase-SR/LR fiber optic transceivers 10Gbps AT-SP10TW direct connect twinax cables with SFP+ transceiver-style connectors You may use the transceivers to connect switches to other network devices over large distances, build high-speed backbone networks between network devices, or connect high-speed devices, such as servers, to your network. The switches support a variety of short and long distance SFP and SFP+ modules. For a list of supported SFP modules, contact your Allied Telesis representative or visit our web site. Note SFP+ slots 27 and 28 on the AT-x510-28GTX and AT-x510-28GPX Switches and slots 51 and 52 on the AT-x510-52GTX and AT-x51052GPX Switches are initially configured as stacking slots for the VCStack feature. If you intend to use the switch as a stand-alone unit, you must disable the VCStack feature before you can use the slots with standard SFP or SFP+ transceivers. The configuration instructions are provided later in this guide, in “Configuring the Switch for Stand-alone Operations” on page 74. 30 x510 Series Installation Guide for Stand-alone Switches Stacking SFP+ Slots Two of the four SFP+ slots on the front panel of the switch can be used with special stacking transceivers to create a VCStack of up to four switches. The switches of a VCStack act as a single virtual unit. They synchronize their actions so that switching operations, like spanning tree protocols, virtual LANs, and static port trunks, span across all the units and ports. The two main advantages of stacks are: You can manage multiple units simultaneously, which can simplify network management. You have more flexibility in how you configure some of the features. For instance, a static port trunk on a stand-alone switch has to consist of ports from the same switch. In contrast, a static trunk on a stack may consist of ports from different switches in the same stack. The slots for the stacking transceivers are SFP+ slots 27 and 28 on the 28port switches and slots 51 and 52 on the 52-port switches. The stacking transceivers are listed in Table 5. Table 5. Stacking Transceivers Transceiver Model Cable Type Distance AT-StackXS/1.0 Twisted pair 1 meter AT-StackOP/0.3 Fiber optic 300 meters AT-StackOP/9.0 Fiber optic 9 kilometers Note This guide explains how to install the devices as stand-alone units. For instructions on how to install the switches in a stack, refer to the x510 Series Installation Guide for Virtual Chassis Stacking. 31 Chapter 1: Overview eco-friendly Button The eco-friendly button on the front panel of the switch is used to toggle the port LEDs on or off. You might turn off the LEDs to conserve electricity when you are not monitoring the device. You can also toggle the LEDs with the ECOFRIENDLY LED and NO ECOFRIENDLY LED commands in the Global Configuration mode of the command line interface. The switch is said to be operating in a low power mode when the LEDs are turned off. Operating the switch in the low power mode with the LEDs turned off does not interfere with the network operations of the device. The management software on the switch has a command that blinks the LEDs so that you can quickly and easily identify a specific unit among the devices in an equipment rack. It is the FINDME command. The command works on the switch even if you turned off the LEDs with the eco-friendly button or NO ECOFRIENDLY LED command. The Switch ID LED is always on, but it displays different information depending on whether the LEDs are on or off. When the LEDs are on, the ID LED displays the ID number of the switch. When the switch is operating in the low power mode with the LEDs off, the ID LED indicates whether the switch is a stand-alone unit or the master or member switch of a VCStack, as detailed in Figure 12 on page 40. Note Before checking or troubleshooting the network connections to the ports on the switch, you should always check to be sure that the LEDs are on by either pressing the eco-friendly button or issuing the ECOFRIENDLY LED and NO ECOFRIENDLY LED commands in the Global Configuration mode of the command line interface. 32 x510 Series Installation Guide for Stand-alone Switches LEDs Here are descriptions of the LEDs. LEDs for the Twisted Pair Ports The twisted pair ports on the AT-x510-28GTX and AT-x510-52GTX Switches have two LEDs that display link, activity and duplex mode information. The LEDs are shown in Figure 6. Link/Activity LED Duplex Mode LED Link/Activity LED Duplex Mode LED Figure 6. LEDs for the 10/100/1000Base-T Ports on the AT-x510-28GTX and AT-x510-52GTX Switches The LEDs are described in Table 6 on page 34. 33 Chapter 1: Overview Table 6. LEDs on the 10/100/1000Base-T Ports on the AT-x510-28GTX and AT-x510-52GTX Switches LED Link/ Activity LED Duplex Mode LED State Description Solid Green A port has established a 1000 Mbps link to a network device. Flashing Green A port is transmitting or receiving data at 1000 Mbps. Solid Amber A port has established a 10 or 100 Mbps link to a network device. Flashing Amber A port is transmitting or receiving data at 10 or 100 Mbps. Off A port has not established a link with another network device or the LEDs are turned off. To turn on the LEDs, use the eco-friendly button. Green A port is operating in full duplex mode. Amber A port is operating in half-duplex mode at 10 or 100 Mbps. (Half-duplex mode does not apply to 1000 Mbps operation.) Flashing Amber Collisions are occurring on a port operating at 10 or 100 Mbps. The twisted pair ports on the AT-x510-28GPX and AT-x510-52GPX Switches have two LEDs that display link, activity and PoE information. The LEDs are shown in Figure 7 on page 35. Note The duplex mode information for the ports on the AT-x510-28GPX and AT-x510-52GPX Switches can be viewed with the management software. 34 x510 Series Installation Guide for Stand-alone Switches Link/Activity LED PoE LED Link/Activity LED PoE LED Figure 7. LEDs for the 10/100/1000Base-T Ports on the AT-x510-28GPX and AT-x510-52GPX Switches The LEDs are described in Table 7. Table 7. LEDs on the 10/100/1000Base-T Ports on the AT-x510-28GPX and AT-x510-52GPX Switches LED Link/ Activity LED State Description Solid Green A port has established a 1000 Mbps link to a network device. Flashing Green A port is transmitting or receiving data at 1000 Mbps. Solid Amber A port has established a 10 or 100 Mbps link to a network device. Flashing Amber A port is transmitting or receiving data at 10 or 100 Mbps. Off A port has not established a link with another network device or the LEDs are turned off. To turn on the LEDs, use the eco-friendly button. 35 Chapter 1: Overview Table 7. LEDs on the 10/100/1000Base-T Ports on the AT-x510-28GPX and AT-x510-52GPX Switches (Continued) LED PoE LEDs for the SFP Slots State Description Green The switch is detecting a powered device (PD) on the port and is delivering power to it. Solid Amber The switch has shutdown PoE+ on the port because of a fault condition. Flashing Amber The switch is detecting a PD on the port but is not delivering power to it because the maximum power budget has been reached. Off This LED state can result from the following conditions: The port is not connected to a PD. The PD is powered off. The port is disabled in the management software. PoE is disabled on the port. The LEDs on the Ethernet line cards are turned off. To turn on the LEDs, use the eco-friendly button. The LEDs for the SFP slots on the AT-x510-28GSX Switch are located between the slots, as shown in Figure 9. Each SFP slot has one LED. The left-hand LED is for the top slot and the right-hand LED is for the bottom slot. SFP Slot LEDs Figure 8. SFP Slot LEDs on the AT-x510-28GSX Switch 36 x510 Series Installation Guide for Stand-alone Switches The LEDs are described in Table 8. Table 8. SFP Slot LEDs on the AT-x510-28GSX Switch LED Link/Activity LEDs for the SFP+ Slots State Description Off The slot is empty, the SFP transceiver has not established a link to a network device, or the LEDs are turned off. To turn on the LEDs, use the eco-friendly button. Solid green The SFP transceiver has established a link at 10 Mbps, 1000 Mbps or 10 Gbps to a network device. Flashing green The SFP transceiver is receiving or transmitting packets to a network device. The LEDs for the SFP+ slots are located between the slots, as shown in Figure 9. Each SFP+ slot has one LED. The left-hand LED is for the top slot and the right-hand LED is for the bottom slot. SFP Slot LEDs Figure 9. SFP+ Slot LEDs The LEDs are described in Table 9 on page 38. 37 Chapter 1: Overview Table 9. SFP+ Slot LEDs LED Link/Activity LEDs for the Stacking Slots State Description Off The slot is empty, the SFP or SFP+ transceiver has not established a link to a network device, or the LEDs are turned off. To turn on the LEDs, use the ecofriendly button. Solid green The SFP or SFP+ transceiver has established a link at 1000 Mbps or 10 Gbps to a network device. Flashing green The SFP+ transceiver is receiving or transmitting packets to a network device at 10 Gbps. (The LED does not flash for activity at 1000 Mbps.). SFP+ slots 27 and 28 on the 28-port switches and slots 51 and 52 on the 52-port switches may be used as stacking slots to build a VCStack of up to four switches. For background information, refer to the x510 Series Installation Guide for Virtual Chassis Stacking. Table 10 defines the LED states when the slots contain stacking transceivers. Table 10. Stacking Slot LEDs LED Link/Activity Switch ID LED 38 State Description Off The slot is empty, the stacking transceiver has not established a link to a network device, or the LEDs are turned off. To turn on the LEDs, use the eco-friendly button. Solid green The stacking transceiver has established a 10 Gbps link to another switch in the stack. Flashing green The stacking transceiver is receiving or transmitting packets. The Switch ID LED, shown in Figure 10 on page 39, displays the ID number of the switch. A stand-alone switch has the ID number 0. Switches in a VCStack have the numbers 1 to 4. Chapter 5, “Powering On the Switch” on page 69 has the procedure for verifying and, if necessary, changing the ID number of the switch. x510 Series Installation Guide for Stand-alone Switches Switch ID LED Figure 10. Switch ID LED The states of the LED when the switch is not operating in the low power mode are shown in Figure 11. The switch is booting up. The switch has encountered a fault condition. The switch is operating as a stand-alone unit, with the ID number 0. The switch has an ID number of 1 to 4 as part of a VCStack. The dot in the lower right corner flashes when the switch accesses USB memory. Figure 11. Switch ID LED The switch displays the letter “F” for fault on the ID LED if it encounters one of the following problems: A cooling fan has failed. One of the power supplies has failed. The internal temperature of the switch has exceeded the normal operating range and the switch may shut down. 39 Chapter 1: Overview Note You can use the SHOW SYSTEM ENVIRONMENT command in the command line interface to identify the source of the problem. The states of the LED when the switch is operating in the low power mode are shown in Figure 12. The switch is the master switch of a VCStack. The switch is operating as a stand-alone unit. The switch is a member switch of a VCStack. Figure 12. Switch ID LEDs in the Low Power Mode 40 x510 Series Installation Guide for Stand-alone Switches USB Port The management panel has a USB port. You may use the port to store configuration files on flash drives and to restore configuration files to switches whose settings have been lost or corrupted, or to quickly configure replacement units. You may also use the port and flash drives to update the management firmware on the switches. The port is USB2.0 compatible. 41 Chapter 1: Overview Console Port The Console port is used to establish a management session with the switch to configure its features and parameter settings. This type of management uses serial RS-232 and is commonly referred to as local or out-of-band management because it is not conducted over your network. To perform local management, you must be at the location of the switch and must use the management cable included with the switch. To establish a local management session with the switch, connect a terminal or a personal computer with a terminal emulation program to the Console port, which has an RJ-45 style (8P8C) connector, using the provided management cable. The cable has RJ-45 RJ-style (8P8C) and DB-9 (D-sub 9-pin) connectors. The Console port is set to the following specifications: Default baud rate: 9600 bps (Range is 9600 to 115200 bps) Data bits: 8 Parity: None Stop bits: 1 Flow control: None Note These settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulation program. 42 x510 Series Installation Guide for Stand-alone Switches Power Supplies The x510 Series switches have two AC power supplies with separate AC connectors on the back panels. The power supplies, which are not fieldreplaceable, provide a switch with power redundancy and protect against interruptions to network operations in the event one of the power supplies loses power or fails. Power redundancy is available only when both AC connectors on a switch are connected to power sources. The AT-x510-28GPX and AT-x510-52GPX Switches have a PoE budget of 370 watts when both power supplies are active and 185 watts when only one power supply is active. For further information, refer to “Power Budget” on page 27. Refer to “Technical Specifications” on page 85 for the input voltage range. Warning Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 Warning This unit might have more than one power cord. To reduce the risk of electric shock, disconnect all power cords before servicing the unit. E30 Note The switches are powered on or off by connecting or disconnecting the power cords. 43 Chapter 1: Overview 44 Chapter 2 Beginning the Installation The chapter contains the following sections: “Reviewing Safety Precautions” on page 46 “Choosing a Site for the Switch” on page 50 “Unpacking the Switch” on page 51 45 Chapter 2: Beginning the Installation Reviewing Safety Precautions Please review the following safety precautions before beginning the installation procedure. Note Safety statements that have the symbol are translated into multiple languages in the Translated Safety Statements document at www.alliedtelesis.com/support. Warning Class 1 Laser product. L1 Warning Do not stare into the laser beam. L2 Warning Do not look directly at the fiber optic cable ends or inspect the cable ends with an optical lens. L6 Warning To prevent electric shock, do not remove the cover. No userserviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician. To avoid the possibility of electric shock, disconnect electric power to the product before connecting or disconnecting the LAN cables. E1 Warning Do not work on equipment or cables during periods of lightning activity. E2 Warning Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 46 x510 Series Installation Guide for Stand-alone Switches Warning Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. E4 Note Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 Caution Air vents must not be blocked and must have free access to the room ambient air for cooling. E6 Warning Operating Temperatures. All the switches are designed for a maximum ambient temperature of 45° degrees C. Note All Countries: Install product in accordance with local and National Electrical Codes. E8 Warning Only trained and qualified personnel are allowed to install or replace this equipment. E14 Caution Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. E21 47 Chapter 2: Beginning the Installation Caution Risk of explosion if battery is replaced by an incorrect type. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Attention: Le remplacement de la batterie par une batterie de type incorrect peut provoquer un danger d’explosion. La remplacer uniquement par une batterie du même type ou de type équivalent recommandée par le constructeur. Les batteries doivent être éliminées conformément aux instructions du constructeur. E22 Warning Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading. E25 Note Use dedicated power circuits or power conditioners to supply reliable electrical power to the device. E27 Warning This unit might have more than one power cord. To reduce the risk of electric shock, disconnect all power cords before servicing the unit. E30 Note If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra). E35 Caution Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. E36 48 x510 Series Installation Guide for Stand-alone Switches Warning Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips). E37 Warning To reduce the risk of electric shock, the PoE ports on this product must not connect to cabling that is routed outside the building where this device is located. E40 Caution The unit does not contain serviceable components. Please return damaged units for servicing. E42 Warning When you remove an SFP module from this product, the case temperature of the SFP may exceed 40° C (158° F). Exercise caution when handling with unprotected hands. E43 49 Chapter 2: Beginning the Installation Choosing a Site for the Switch Observe these requirements when planning the installation of the switch. If you plan to install the switch in an equipment rack, check to be sure that the rack is safely secured so that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack. If you plan to install the switch on a table, check to be sure that the table is level and stable. The power outlet should be located near the switch and be easily accessible. The site should allow for easy access to the ports on the front of the switch, so that you can easily connect and disconnect cables, and view the port LEDs. The site should allow for adequate air flow around the unit and through the cooling vents on the front and rear panels. (The ventilation direction in units that have a cooling fan is from front to back, with the fan on the back panel drawing the air out of the unit.) The site should not expose the switch to moisture or water. The site should be a dust-free environment. The site should include dedicated power circuits or power conditioners to supply reliable electrical power to the network devices. Do not install the switch in a wiring or utility box because it will overheat and fail from inadequate airflow. Warning Switches should not be stacked on top of one another on a table or desktop because that could present a personal safety hazard if you need to move or replace switches. 50 x510 Series Installation Guide for Stand-alone Switches Unpacking the Switch Figure 13 lists the items that come with the switch. If any item is missing or damaged, contact your Allied Telesis sales representative for assistance. One 2 m (6.6 ft) local management cable with RJ-45 (8P8C) and DB-9 (D-sub 9-pin) connectors. Two rack mounting brackets Two regional AC power cords Eight bracket screws Figure 13. Components of the x510 Series Switches Note You should retain the original packaging material in the event you need to return the unit to Allied Telesis. 51 Chapter 2: Beginning the Installation 52 Chapter 3 Installing the Switch on a Table or in an Equipment Rack The procedures in this chapter are: “Installing the Switch on a Table or Desktop” on page 54 “Installing the Switch in an Equipment Rack” on page 55 53 Chapter 3: Installing the Switch on a Table or in an Equipment Rack Installing the Switch on a Table or Desktop You may install the switch on a table or desktop. Here are the guidelines to selecting a site: The table should be level and stable. The power outlet should be located near the switch and be easily accessible. The site should allow for easy access to the ports on the front of the switch, so that you can easily connect and disconnect cables, and view the port LEDs. The site should allow for adequate air flow around the unit and through the cooling vents on the front and rear panels. (The ventilation direction in units that have a cooling fan is from front to back, with the fans on the back panels drawing the air out of the units.) The site should not expose the switch to moisture or water. The site should be a dust-free environment. The site should include dedicated power circuits or power conditioners to supply reliable electrical power to the network devices. The rubber feet on the bottom of the switch should be left on for table or desktop installation. Warning Do not stack switches on top of one another on a table or desktop because that could present a personal safety hazard if you need to move or replace switches. After placing the switch on the table or desktop, go to Chapter 4, “Cabling the Networking Ports” on page 59 to connect the network cables to the ports on the switch. 54 x510 Series Installation Guide for Stand-alone Switches Installing the Switch in an Equipment Rack This procedure requires the following items: Eight bracket screws (included with the switch) Two equipment rack brackets (included with the switch) Flat-head screwdriver (not provided) Cross-head screwdriver (not provided) Four standard equipment rack screws (not provided) Installation guidelines may be found in “Choosing a Site for the Switch” on page 50. Here is the procedure for installing the switch in a 19-inch equipment rack. Caution The chassis may be heavy and awkward to lift. Allied Telesis recommends that you get assistance when mounting the chassis in an equipment rack. E28 1. Place the unit upside down on a level, secure surface. Figure 14. Turning the Switch Upside Down 2. Using a flat-head screwdriver, pry the rubber feet from the bottom of the switch. Refer to Figure 15. Figure 15. Removing the Rubber Feet 55 Chapter 3: Installing the Switch on a Table or in an Equipment Rack 3. Turn the switch over. 4. Attach the two rack mount brackets to the sides of the switch using the eight bracket screws included with the unit. Figure 16 and Figure 17 on page 57 illustrate the four possible bracket positions. Figure 16. Attaching the Equipment Rack Brackets 56 x510 Series Installation Guide for Stand-alone Switches Figure 17. Attaching the Equipment Rack Brackets (Continued) 5. While another person holds the switch in the equipment rack, secure it using standard equipment rack screws (not provided), as shown in Figure 18. Figure 18. Mounting the Switch in an Equipment Rack Go to Chapter 4, “Cabling the Networking Ports” on page 59, to connect the network cables to the ports on the switch. 57 Chapter 3: Installing the Switch on a Table or in an Equipment Rack 58 Chapter 4 Cabling the Networking Ports This chapter contains the following procedures: “Cabling the Twisted Pair Ports” on page 60 “Installing SFP and SFP+ Transceivers” on page 62 59 Chapter 4: Cabling the Networking Ports Cabling the Twisted Pair Ports Here are the guidelines to cabling the 10/100/1000Base-T twisted pair ports: 60 The cable specifications for the 10/100/1000Base-T twisted pair ports are listed in Table 1 on page 24. The connectors on the cables should fit snugly into the ports, and the tabs should lock the connectors into place. The default setting for the wiring configurations of the ports is autoMDI/MDI-X. The default setting is appropriate for switch ports that are connected to 10/100Base-TX network devices that also support auto-MDI/MDI-X. The default auto-MDI/MDI-X setting is not appropriate for switch ports that are connected to 10/100Base-TX network devices that do not support auto-MDI/MDI-X and have a fixed wiring configuration. For switch ports connected to those types of network devices, you should disable auto-MDI/MDI-X and set the wiring configurations manually. The appropriate MDI/MDI-X setting for a switch port connected to a 10/100Base-TX network device with a fixed wiring configuration depends on the setting of the network device and whether the switch and network device are connected with straight-through or crossover cable. If you are using straight-through twisted pair cable, the wiring configurations of a port on the switch and a port on a network device must be opposite each other, such that one port uses MDI and the other MDI-X. For example, if a network device has a fixed wiring configuration of MDI, you must disable auto-MDI/MDI-X on the corresponding switch port and manually set it to MDI-X. If you are using crossover twisted pair cable, the wiring configurations of a port on the switch and a port on a network device must be the same. The default speed setting for the ports is Auto-Negotiation. This setting is appropriate for ports connected to network devices that also support Aut-Negotiation. The default speed setting of Auto-Negotiation is not appropriate for ports connected to 10/100Base-TX network devices that do not support Auto-Negotiation and have fixed speeds. For those switch ports, you should disable Auto-Negotiation and set the port’s speed manually to match the speeds of the network devices. The 10/100/1000Base-T ports must be set to Auto-Negotiation, the default setting, to operate at 1000Mbps. The default duplex mode setting for the ports is Auto-Negotiation. This setting is appropriate for ports connected to network devices that also support Auto-Negotiation for duplex modes. x510 Series Installation Guide for Stand-alone Switches The default duplex mode setting of Auto-Negotiation is not appropriate for ports connected to network devices that do not support Auto-Negotiation and have a fixed duplex mode. You should disable Auto-Negotiation on those ports and set their duplex modes manually to avoid the possibility of duplex mode mismatches. A switch port using Auto-Negotiation defaults to halfduplex if it detects that the end node is not using Auto-Negotiation, which can result in a mismatch if the end node is operating at a fixed duplex mode of full-duplex. Do not attach cables to ports of static or LACP port trunks until after you have configured the trunks on the switch. Otherwise, the ports will form network loops that can adversely affect network performance. 61 Chapter 4: Cabling the Networking Ports Installing SFP and SFP+ Transceivers This section contains guidelines and procedures for installing SFP and SFP+ transceivers. The installation procedures are listed here: “Installing SFP Modules in the AT-x510-28GSX Switch” on page 63 “Installing SFP and SFP+ Modules” on page 66 Here are general installation guidelines for SFP and SFP+ transceivers: SFP and SFP+ transceivers are hot-swappable. You may install them while the chassis is powered on. Your Allied Telesis sales representative can provide you with a list of supported transceivers for the units. The operational specifications and fiber optic cable requirements of the transceivers are provided in the documents included with the devices. You should install a transceiver before connecting the fiber optic cable. Fiber optic transceivers are dust sensitive. Always keep the plug in the optical bores when a fiber optic cable is not installed, or when you store the transceiver. When you do remove the plug, keep it for future use. Unnecessary removal and insertion of a transceiver can lead to premature failure. Warning A transceiver can be damaged by static electricity. Be sure to observe all standard electrostatic discharge (ESD) precautions, such as wearing an antistatic wrist strap, to avoid damaging the device. Note SFP+ slots 27 and 28 on the 28-port switches and slots 51 and 52 on the 52-port switches are initially configured as stacking slots for the VCStack feature. If you intend to use the switch as a stand-alone unit, you must disable the VCStack feature before you can use the slots with standard SFP or SFP+ transceivers. For instructions, refer to Chapter 5, “Powering On the Switch” on page 69. 62 x510 Series Installation Guide for Stand-alone Switches Installing SFP Modules in the AT-x510-28GSX Switch To install SFP transceivers in slots 1 to 24 of the AT-x510-28GSX Switch, perform the following procedure: 1. Remove the dust plug from a transceiver slot on the switch. Refer to Figure 19. Figure 19. Removing the Dust Plug from an SFP Slot 2. Remove the transceiver from its shipping container and store the packaging material in a safe location. 3. If you are installing the transceiver in a top slot, position the transceiver with the Allied Telesis label facing up. If you are installing the transceiver in a bottom slot, position the transceiver with the label facing down. 4. Slide the transceiver into the slot until it clicks into place, as shown in Figure 20 on page 64. 63 Chapter 4: Cabling the Networking Ports Figure 20. Installing an SFP Transceiver Note If you are ready to attach the fiber optic cable to the transceiver, continue with the next step. Otherwise, repeat steps 1 to 4 to install the remaining SFP transceivers in the switch. 5. Remove the dust cover from the transceiver, as shown in Figure 21. Figure 21. Removing the Dust Cover from an SFP Transceiver 6. Verify the position of the handle on the SFP transceiver. If the transceiver is in a top slot, the handle should be in the upright position, as shown in Figure 22 on page 65. If the transceiver is in a bottom slot, the handle should be in the down position. 64 x510 Series Installation Guide for Stand-alone Switches SFP Handle Figure 22. Positioning the SFP Handle in the Upright Position 7. Connect the fiber optic cable to the transceiver, as shown in Figure 23. The connector on the cable should fit snugly into the port, and the tab should lock the connector into place. Figure 23. Connecting a Fiber Optic Cable to an SFP Transceiver 8. Repeat this procedure to install additional transceivers. 65 Chapter 4: Cabling the Networking Ports Installing SFP and SFP+ Modules To install SFP and SFP+ transceivers in slots 27 and 28 of the 28-port switches and slots 51 and 52 of the 52-port switches, perform the following procedure: 1. Remove the dust plug from a transceiver slot on the switch. Refer to Figure 24 on page 66. Figure 24. Removing the Dust Plug from an SFP+ Slot 2. Remove the transceiver from its shipping container and store the packaging material in a safe location. 3. If you are installing the transceiver in a top slot, position the transceiver with the Allied Telesis label facing up. If you are installing the transceiver in a bottom slot, position the transceiver with the label facing down. 4. Slide the transceiver into the slot until it clicks into place, as shown in Figure 25 on page 67. 66 x510 Series Installation Guide for Stand-alone Switches Figure 25. Installing an SFP or SFP+ Transceiver Note If you are ready to attach the fiber optic cable to the transceiver, continue with the next step. Otherwise, repeat steps 1 to 4 to install the remaining SFP or SFP+ transceivers in the switch. 5. Remove the dust cover from the transceiver, as shown in Figure 26. Figure 26. Removing the Dust Cover from an SFP or SFP+ Transceiver 67 Chapter 4: Cabling the Networking Ports 6. Verify the position of the handle on the SFP transceiver. If the transceiver is in a top slot, the handle should be in the upright position, as shown in Figure 27. If the transceiver is in a bottom slot, the handle should be in the down position. SFP Handle Figure 27. Positioning the SFP or SFP+ Handle in the Upright Position 7. Connect the fiber optic cable to the transceiver, as shown in Figure 28. The connector on the cable should fit snugly into the port, and the tab should lock the connector into place. Figure 28. Connecting a Fiber Optic Cable to an SFP or SFP+ Transceiver 8. Repeat this procedure to install additional transceivers. 68 Chapter 5 Powering On the Switch This chapter contains the following procedures: “Powering On the Switch” on page 70 “Configuring the Switch for Stand-alone Operations” on page 74 “Specifying Ports in the Command Line Interface for Stand-alone Switches” on page 80 69 Chapter 5: Powering On the Switch Powering On the Switch To power on the switch, connect the power cords to the connectors on the back panels and to the appropriate power sources. All the models have two power supplies with separate connectors. Figure 29. Plugging in the AC Power Cord Consider the following items as you power on the switch: Connecting the two power cords to power sources that are on different circuits will provide power redundancy to the switch in the event a circuit fails. Refer to “Power Specifications” on page 86 for the power specifications of the switches. Warning Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 Note Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 70 x510 Series Installation Guide for Stand-alone Switches Monitoring the Initialization Processes It takes about thirty seconds for the switch to initialize its management software programs and features, and load the default configuration. You may monitor the progress of the initialization process by watching the switch ID LED. It displays the number “8” for about the first 15 seconds and then displays the number “1.” You may also monitor the bootup sequence by connecting a terminal or computer that has a terminal emulator program, to the Console port on the master switch. You will see the messages in Figure 30 here to Figure 32 on page 73. Bootloader 2.0.11 loaded Pressfor the Boot Menu Reading filesystem... Loading flash:x510-5.4.2a-20120727-1.rel... Verifying release... OK Booting... Starting base/first... [ OK ] Mounting virtual filesystems... [ OK ] ______________ /\ \ / / / / /______\ \ \_ \ | \ \ ____ __/ /| ______ | | / / / | ______ | \ ____ / /______/\____\ \/ /____________/ Allied Telesis Inc. AlliedWare Plus (TM) v5.4.2A Current release filename: x510-5.4.2a-20120727-1.rel Original release filename: x510-5.4.2A-20120727-1.rel Built: Fri Jul 27 04:11:42 NZST 2012 by: maker@maker04-build Mounting static filesystems... [ OK ] Checking flash filesystem... [ OK ] Mounting flash filesystem... [ OK ] Checking NVS filesystem... [ OK ] Mounting NVS filesystem... [ OK ] Starting base/dbus... [ OK ] Starting base/syslog... [ OK ] Figure 30. Switch Initialization Messages 71 Chapter 5: Powering On the Switch Starting base/loopback... [ OK ] Starting base/poe_done... [ OK ] Starting base/sysctl... [ OK ] [ OK ] Starting base/reboot-stability... [ OK ] Starting base/autofs-card... [ OK ] Checking system reboot stability... [ OK ] Starting base/cron... [ OK ] Starting base/appmond... [ OK ] Starting hardware/openhpi... [ OK ] Starting hardware/timeout... [ OK ] Starting base/inet... [ OK ] Starting base/modules... [ OK ] Starting network/startup... [ OK ] Starting network/stackd... [ OK ] Starting network/election.timeout... [ OK ] Received event poefw.done Starting base/portmapper... Received event syslog.done Received event modules.done Received event board.inserted Received event hardware.done Received event network.enabled Initializing HA processes: openhpid, hostd, cntrd, nsm, auth, epsr, hsl imiproxyd, irdpd, lldpd, loopprot, mstp, ospf6d, ripd ripngd, rmon, sflowd, udldd, vrrpd, bgpd, imi lacp, ospfd, pdmd, pimd Received event network.initialized 03:44:11 awplus-1 VCS[826]: No neighboring members found, unit may be in a stand alone configuration 03:44:11 awplus-1 VCS[826]: Startup speed can be improved by adding 'no stack 1 enable' to configuration Received event vcs.elected-master 03:44:11 awplus-1 VCS[826]: Member 1 (0015.774f.ed30) has become the Active Master Figure 31. Switch Initialization Messages (Continued) 72 x510 Series Installation Guide for Stand-alone Switches Assigning Active Workload to HA processes: hsl, nsm, rmond, sflowd, vrrpd, irdpd, lacpd lldpd, loopprotd, mstpd, authd, epsrd, imi, imiproxyd Received event network.activated Loading default configuration Warning: flash:/default.cfg does not exist, loading factory defaults. .. done! Received event network.configured awplus login: Figure 32. Switch Initialization Messages (Continued) After the switch has initialized its management software, go to “Configuring the Switch for Stand-alone Operations” on page 74 to confirm its ID number. 73 Chapter 5: Powering On the Switch Configuring the Switch for Stand-alone Operations After the switch has initialized its management software, examine the switch ID LED on the front panel and do one of the following: If the LED is displaying “0,” the installation procedure is complete. The switch is now ready for network operations as a stand-alone unit. Refer to the Software Reference for x510 Series Switches, AlliedWare Plus Operating System, for instructions on how to configure the operating parameters. If the LED is displaying a number other than “0,” perform the following procedures to disable the VCStack feature. You can disable the VCStack feature from a local management session of the switch using the Console port. To start a local management session, go to “Starting a Local Management Session,” next. Caution You have to reset the switch to disable the VCStack feature. Some network traffic may be lost if the device is already connected to a live network. Note The initial management session of the switch must be from the Console port. Starting a Local Management Session This procedure requires a terminal or a terminal emulator program and the management cable that comes with the switch. To start a local management session on the switch, perform the following procedure: 1. Connect the RJ-45 connector on the management cable to the Console port on the front panel of the switch, as shown in Figure 33 on page 75. 74 x510 Series Installation Guide for Stand-alone Switches Figure 33. Connecting the Management Cable to the Console Port 2. Connect the other end of the cable to an RS-232 port on a terminal or PC with a terminal emulator program. 3. Configure the terminal or terminal emulator program as follows: Baud rate: 9600 bps (The baud rate of the Console Port is adjustable from 1200 to 115200 bps. The default is 9600 bps.) Data bits: 8 Parity: None Stop bits: 1 Flow control: None Note The port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program. 4. Press Enter. You are prompted for a user name and password. 5. When prompted for a user name, go to “Disabling VCStack” on page 76. 75 Chapter 5: Powering On the Switch Disabling VCStack To disable the VCStack feature to use the switch as stand-alone unit, perform the following procedure: Caution Disabling the VCStack feature requires resetting the switch. If the switch is already connected to a live network, some network traffic may be lost. 1. When prompted, enter a user name and password to log on the switch. If this is the initial management session of the switch, enter “manager” as the user name and “friend” as the password. The user name and password are case sensitive. The local management session starts when the User Exec mode prompt, shown in Figure 34. is displayed. awplus> Figure 34. User Exec Mode Prompt Note The User Exec mode is the first level in the command mode interface. For complete information on the modes and commands, refer to the Software Reference for x510 Series Switches, AlliedWare Plus Operating System from www.alliedtelesis.com. 2. Enter the SHOW STACK command to display the status of the VCStack feature. Figure 35 is an example of the command. awplus> show stack Virtual Chassis Stacking summary information ID 1 Pending ID - MAC address 0015:774f:ed30 Operational Status Stack MAC address Priority 128 Status Ready Role Active Master Standalone Unit 0015:774f:ed30 awplus(config)# Figure 35. SHOW STACK Command 3. Review the following items: 76 If the Operational Status is “Stacking Hardware Disabled,” the VCStack feature is already disabled on the switch and the SFP+ stacking slots may be used with regular SFP or SFP+ transceivers. x510 Series Installation Guide for Stand-alone Switches If the Operational Status is “Standalone Unit,” as shown in Figure 35 on page 76, the VCStack feature is active on the unit. You must disable it by performing the steps in the rest of this procedure before you can use the SFP+ stacking slots with regular SFP or SFP+ transceivers. The reason the status says “standalone” is because the switch considers itself a stack of one switch. 4. Move to the Global Configuration mode by entering the ENABLE and CONFIGURE TERMINAL commands, as shown in Figure 36. awplus> enable awplus# configure terminal Enter configuration commands, one per line. End with CNTL/Z awplus(config)# Figure 36. Moving to the Global Configuration Mode 5. To. disable the VCStack feature on the switch, enter the NO STACK ENABLE command, which has this format: no stack id enable The ID parameter is the ID number of the switch, displayed on the ID LED. Replace the parameter with whatever number is on the ID LED. For example, if the ID number of the switch is 1, the default value, enter the command as follows: awplus(config)# no stack 1 enable This confirmation prompt in Figure 37 is displayed. Warning; This will disable the stacking hardware on member-1. Are you sure you want to continue? (y/n): Figure 37. Confirmation Prompt for the NO STACK ENABLE Command 6. Type Y to disable VCStack on the switch or N to cancel the procedure. 7. Enter the EXIT command to return to the Privileged Exec mode, as shown in Figure 38. awplus(config)# exit awplus# Figure 38. Returning to the Privileged Exec Mode 8. Enter the WRITE command to save your change in the configuration file. The switch displays the confirmation prompt in Figure 39 on page 78. 77 Chapter 5: Powering On the Switch awplus# write Building configuration ... [OK] awplus# Figure 39. Saving the Changes with the WRITE Command 9. Enter the REBOOT command to reboot the switch. 10. At the confirmation prompt, type “Y” for yes. 11. Wait for the switch to initialize its management software and afterwards examine the Switch ID LED. The switch is ready for normal network operations as a stand-alone unit when its ID number is “0.” Refer to the Software Reference for x510 Series Switches, AlliedWare Plus Operating System, for instructions on how to configure the operating parameters. If the number is not “0,” repeat this procedure. Confirming the Status of the VCStack Feature Another way to confirm that VCStack is disabled on the switch is by displaying the status of the last two SFP+ slots on the switch. These are slots 27 and 28 on the 28-port switches and slots 51 and 52 on the 52-port switches. If VCStack is disabled, you should be able to display the status of the slots even when they do not have transceivers. If VCStack is not disabled, the switch displays a message that it cannot find the slots. To view the status of the stacking slots, perform this procedure: 1. Start a management session on the switch. For directions, refer to “Configuring the Switch for Stand-alone Operations” on page 74. 2. Log on to the switch. The default user name is “manager” and the password is “friend”. 3. From either the User Exec mode or Privileged Exec mode, enter the SHOW INTERFACE command to display the status of one of the last two SFP+ slots on the switch. For example, for the AT-x510-28GTX Switch, enter this command to view the status of slot 27: show interface port1.0.27 4. For the AT-x510-52GTX Switch, enter this command to view the status of slot 51: show interface port1.0.51 If VCStack is disabled, the switch displays the status of the designated slot. An example is shown in Figure 40 on page 79. 78 x510 Series Installation Guide for Stand-alone Switches awplus>show interface port1.0.51 Interface port1.0.51 Scope: both Link is DOWN, administrative state is UP Thrash-limiting Status Not Detected, Action learn-disable, Timeout 1(s) Hardware is Ethernet, address is 0015.774f.ed30 index 5051 metric 1 mru 1500 configured duplex auto, configured speed auto, configured polarity auto SNMP link-status traps: Disabled input packets 0, bytes 0, dropped 0, multicast packets 0 output packets 0, bytes 0, multicast packets 0 broadcast packets 0 Time since last state change: 0 days 00:42:49 Figure 40. Status of a Stacking Slot When VCStack is Disabled The switch displays the message in Figure 41 if VCStack is not disabled, in which case you need to disable it by performing the commands in “Disabling VCStack” on page 76. awplus# show interface port1.0.51 %Can’t find interface port1.0.51 awplus# Figure 41. Status of a Stacking Slot When VCStack is Enabled 79 Chapter 5: Powering On the Switch Specifying Ports in the Command Line Interface for Stand-alone Switches The command line interface in the management software on the switch has a parameter that you use to specify the individual ports. The parameter is the PORT parameter and Figure 42 shows its format. port1.0.n Stack ID Module ID Port Number Figure 42. PORT Parameter in the Command Line Interface The first number is the switch’s ID number. The ID number for stand-alone switches is not the value 0 displayed on the Switch ID LEDs. Rather, it is 1. Be sure to enter 1, not 0, as the ID number in the PORT parameter when configuring ports on stand-alone switches. The module ID value is used with multi-module products. This value does not apply to the x510 Series switches and should always be 0. The third value is a port number on the switch. You may specify only one port number in a PORT parameter, but you may specify more than one PORT parameter in many commands where the parameter is supported. Here is an example of the PORT parameter on a stand-alone switch. It uses the INTERFACE command to enter the Port Interface mode for ports 15 and 17: awplus> enable awplus# configure terminal awplus(config)# interface port1.0.15,port1.0.17 For instructions on the command line interface and the PORT parameter, refer to the Software Reference for x510 Series Switches, AlliedWare Plus Operating System. 80 Chapter 6 Troubleshooting This chapter contains suggestions on how to troubleshoot the switch if a problem occurs. Note For further assistance, please contact Allied Telesis Technical Support at www.alliedtelesis.com/support. Problem 1: The Switch ID LED on the front of the switch is off. Solutions: The unit is not receiving power. Try the following: Verify that the power cord is securely connected to the power source and to the AC connector on the back panel of the switch. Verify that the power outlet has power by connecting another device to it. Try connecting the unit to another power source. Try a different power cord. Verify that the voltage from the power source is within the required levels for your region. Problem 2: All of the port LEDs are off even though the ports are connected to active network devices. Solution: The switch may be operating in the low power mode. To toggle on the LEDs, press the eco-friendly button on the front panel of the switch. You may also toggle the LEDs off and on with the ECOFRIENDLY LED and NO ECOFRIENDLY LED commands in the command line interface. Problem 3: A twisted pair port on the switch is connected to a network device but the port’s LINK/ACT LED is off. Solutions: The port is unable to establish a link to a network device. Try the following: Verify that the port is connected to the correct twisted pair cable. This is to eliminate the possibility that the port is connected to the wrong network device. Verify that the network device connected to the twisted pair port is powered on and is operating properly. 81 Chapter 6: Troubleshooting Try connecting another network device to the twisted pair port with a different cable. If the twisted pair port is able to establish a link, then the problem is with the cable or the other network device. Verify that the twisted pair cable does not exceed 100 meters (328 feet). Verify that you are using the appropriate category of twisted pair cable. The cable types are listed in Table 1 on page 24 for the 10/ 100/1000Base-T ports. Note A 1000Base connection may require five to ten seconds to establish a link. Problem 4: The LINK/ACT LED for an SFP or SFP+ transceiver is off. Solutions: The fiber optic port on the transceiver is unable to establish a link to a network device. Try the following: 82 Verify that the remote network device connected to the fiber optic port is operating properly. Verify that the fiber optic cable is securely connected to the port on the SFP or SFP+ module and to the port on the remote network device. Check that the transceiver is fully inserted in the slot. If you are using SFP+ slots 27 or 28 on the 28-port switches or slots 51 and 52 on the 52-port switches, check that VCStack is disabled on the switch. The VCStack feature has to be disabled before you can use these slots for regular SFP or SFP+ transceivers. For instructions, refer to “Configuring the Switch for Stand-alone Operations” on page 74 Verify that the operating specifications of the fiber optic ports on the transceiver and remote network device are compatible. Verify that the correct type of fiber optic cabling is being used. Verify that the port is connected to the correct fiber optic cable. This is to eliminate the possibility that the port is connected to the wrong remote network device. Try connecting another network device to the fiber optic port using a different cable. If the port is able to establish a link, then the problem is with the cable or with the other network device. Use the switch’s management software to verify that the port is enabled. If the remote network device is a managed device, use its management firmware to determine whether its port is enabled. x510 Series Installation Guide for Stand-alone Switches Test the attenuation of both directions on the fiber optic cable with a fiber optic tester to determine whether the optical signal is too weak (sensitivity) or too strong (maximum input power). Problem 5: Network performance between a twisted pair port on the switch and a network device is slow. Solution: There might be a duplex mode mismatch between the port and the network device. This can occur when a twisted pair port using AutoNegotiation is connected to a remote device that has a fixed speed of 10 or 100 Mbps and a fixed duplex mode of full duplex. If this is the cause of the problem, adjust the duplex mode of the port on the network device or switch so that both ports are using the same duplex mode. You can use either the LEDs or management software on the switch to determine the duplex mode settings of the ports. The LEDs are described in Table 6 on page 34. Problem 6: The switch functions intermittently. Solutions: Check the system hardware status through the management software: Use the SHOW SYSTEM ENVIRONMENT command in the Privileged Exec mode to verify that the input voltage from the power source to the switch is stable and within the approved operating range. The unit will shutdown if the input voltage fluctuates above or below the approved operating range. Use the SHOW SYSTEM ENVIRONMENT command in the Privileged Exec mode to verify that the fan is operating correctly. Verify that the location of the switch allows for adequate airflow. The unit will shutdown if it is in danger of overheating. Problem 7: The Switch ID LED on the front of the switch is flashing the letter “F.” Solutions: One or more of the following problems has occurred: A cooling fan has failed. One of the power supplies has failed. The input voltage on one or both of the power supplies is outside the normal operating range. The internal temperature of the switch has exceeded the normal operating range and the switch may shut down. Contact your Allied Telesis sales representative for assistance. 83 Chapter 6: Troubleshooting Problem 8: The AT-x510-28GPX or AT-x510-52GPX Switch is not providing power to a PoE device. Solutions: Try the following: 84 Review the PD’s documentation to confirm that the device supports Mode A of the IEEE 802.3at standard. Mode A is one of two modes that define the connector pins that deliver the power from the port on the line card to the PD. In Mode A, the power is carried on pins 1, 2, 3, and 6 on the RJ-45 port, the same pins that carry the network traffic. The second mode, Mode B, defines pins 4, 5, 7, and 8 as the power carriers. The AT-x510-28GPX and ATx510-52GPX Switches do not support Mode B. Most powered devices are designed to accept power by either mode, but some legacy devices may only support one mode. This can be verified by reviewing the device’s documentation or data sheet. Legacy devices that only support Mode B will not work with the switches. Check that the device’s power requirements do not exceed 30 W. This can be verified by reviewing the device’s documentation or data sheet. Verify that you are using the appropriate category of twisted-pair cable by referring to Table 3 on page 26. Use the management software on the switch to determine whether PoE is enabled on the port. The default setting for PoE is enabled. Use the management software on the switch to determine whether the PoE power setting for the port has been reduced to a value below the power requirements of the device. Try connecting the device to a different port on the switch. Appendix A Technical Specifications Physical Specifications Dimensions (H x W x D) Table 11. Product Dimensions AT-x510-28GTX 4.4 cm x 44.0 cm x 32.3 cm (1.7 in. x 17.3 in. x 12.7 in.) AT-x510-28GPX 4.4 cm x 44.0 cm x 39.8 cm (1.7 in. x 17.3 in. x 15.7 in.) AT-x510-28GSX 4.4 cm x 44.0 cm x 32.3 cm (1.7 in. x 17.3 in. x 12.7 in.) AT-x510-52GTX 4.4 cm x 44.0 cm x 32.3 cm (1.7 in. x 17.3 in. x 12.7 in.) AT-x510-52GPX 4.4 cm x 44.0 cm x 40.0 cm (1.7 in. x 17.3 in. x 15.7 in.) Weights Table 12. Product Weights AT-x510-28GTX 4.3 kg (9.5 lb.) AT-x510-28GPX 5.8 kg (12.8 lb.) AT-x510-28GSX 4.8 kg (10.6 lb.) AT-x510-52GTX 5.2 kg (11.5 lb.) AT-x510-52GPX 6.2 kg (13.7 lb.) Ventilation Table 13. Ventilation Requirements Recommended Minimum Ventilation on All Sides 10 cm (4.0 in) 85 Appendix A: Technical Specifications Environmental Specifications Table 14. Environmental Specifications Operating Temperature 0° C to 45° C (32° F to 113° F) Storage Temperature -25° C to 70° C (-13° F to 158° F) Operating Humidity 5% to 90% noncondensing Storage Humidity 5% to 95% noncondensing Maximum Operating Altitude 3,000 m (9,842 ft) Maximum Nonoperating Altitude 4,000 m (13,100 ft) Power Specifications Maximum Power Consumption Table 15. Maximum Power Consumption AT-x510-28GTX 40 watts per input AT-x510-28GPX 210 watts per input AT-x510-28GSX 40 watts per input AT-x510-52GTX 70 watts per input AT-x510-52GPX 270 watts per input Input Voltages Table 16. Input Voltages 86 AT-x510-28GTX AC model: 100-240 VAC, 1.0A maximum, 50/60 Hz per input AT-x510-28GPX AC model: 100-240 VAC, 3.0A maximum, 50/60 Hz per input AT-x510-28GSX AC model: 100-240 VAC, 1.0A maximum, 50/60 Hz per input AT-x510-52GTX AC model: 100-240 VAC, 1.0A maximum, 50/60 Hz per input x510 Series Installation Guide for Stand-alone Switches Table 16. Input Voltages (Continued) AT-x510-52GPX AC model: 100-240 VAC, 3.0A maximum, 50/60 Hz per input Certifications Table 17. Product Certifications EMI (Emissions) FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, CISPR Class A, C-TICK, CE EMC (Immunity) EN55024 Electrical and Laser Safety EN60950-1 (TUV), UL 60950-1 (CULUS), EN60825 Compliance Marks CE, CULUS, TUV, C-Tick RJ-45 Twisted Pair Port Pinouts Figure 43 illustrates the pin layout of the RJ-45 connectors and ports. Figure 43. RJ-45 Socket Pin Layout (Front View) Table 18 lists the pin signals for 10 and 100 Mbps. Table 18. Pin Signals for 10 and 100 Mbps Pin MDI Signal MDI-X Signal 1 TX+ RX+ 2 TX- RX- 87 Appendix A: Technical Specifications Table 18. Pin Signals for 10 and 100 Mbps (Continued) Pin MDI Signal MDI-X Signal 3 RX+ TX+ 4 Not used Not used 5 Not used Not used 6 RX- TX- 7 Not used Not used 8 Not used Not used Table 19 lists the pin signals when a port operating at 1000 Mbps. Table 19. Pin Signals for 1000 Mbps Pinout Pair 1 Pair 1 + 2 Pair 1 - 3 Pair 2 + 4 Pair 3 + 5 Pair 3 - 6 Pair 2 - 7 Pair 4 + 8 Pair 4 - RJ-45 Style Serial Console Port Pinouts Table 20 lists the pin signals of the RJ-45 style serial Console port. Table 20. RJ-45 Style Serial Console Port Pin Signals Pin 88 Signal 1 Looped to pin 8. 2 Looped to pin 7. x510 Series Installation Guide for Stand-alone Switches Table 20. RJ-45 Style Serial Console Port Pin Signals (Continued) Pin Signal 3 Transmit Data 4 Ground 5 Ground 6 Receive Data 7 Looped to pin 2. 8 Looped to pin 1. 89 Appendix A: Technical Specifications 90
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : Allied Telesis, Inc. Create Date : 2013:06:07 09:41:06Z Modify Date : 2013:06:25 14:13:03-07:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : FrameMaker 9.0 Metadata Date : 2013:06:25 14:13:03-07:00 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : AT-x510 Series Installation Guide for Stand-alone Switches Creator : Allied Telesis, Inc. Document ID : uuid:da564147-16be-461b-97ad-9a8e7e77eced Instance ID : uuid:be1adf29-514f-488a-8ffd-398363974989 Page Mode : UseOutlines Page Count : 90 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools