Andon Health MB3 BodyRhythm User Manual MB3 x
Andon Health Co., Ltd BodyRhythm MB3 x
MB3 User Manual
iMusicBodyRhythm OWNER’S MANUAL TABLE OF CONTENTS INTRODUCTION WARNINGS AND CAUTIONS PACAKAGE CONTENTS INTENDED USE PARTS AND DISPLAY INDICATORS SET UP REQUIREMENTS SET UP PROCEDURES INSTRUCTIONS FOR USE SPECIFICATIONS TROUBLESHOOTING CARE AND MAINTENANCE WARRANTY INFORMATION EXPLANATION OF SYMBOLS ELECTROMAGNETIC COMPATIBILITY INFORMATION SERVICE CENTER INFORMATION To ensure safety and correct usage of the BodyRhythm, all of the safety and operating instructions should be read and followed before using it. INTRODUCTION Thank you for selecting the i-Music BodyRhythm. The i-Music BodyRhythm is designed to give you pleasure and fun. The main functions are in the following: • 5 different auto rhythmic tap modes work without iOS devices. Each of the mode lasts 15 minutes. • Drumbeat tap in sync with music rhythm with iOS devices • Drumbeat tap as what you create with iOS devices • Share the rhythmic tap with your friends with iOS devices PACKAGE CONTENTS • • • • 1 Main Uit 1 Power Cord 1 Owner’s Manual 1 Quick Start Guide INTENDED USE TheiMusic BodyRhythm is intended for adult to use in an indoor environment. It is designed to relieve fatigue and tiredness when you listen to the music. PARTS AND DISPLAY INDICATORS Main unit (Back view) Main unit (Front view) 1. Main Unit 2. Air Openings 3. 4. 5. 6. 7. 8. Control Panel Zip Power Cord Power Plug Handle Strap DC Jack Control Panel ‘Start’/’Stop’ button to control the BodyRhythm ‘Auto Mode’ button to adjust the different auto rhythmic modes ‘Intensity Level Up’ button to turn up the intensity ‘Intensity Level Down’ button to turn down the intensity SET UP REQUIREMENTS The iMusic BodyRhythm is designed to be used with the following iPod touch and iPhone models: iPhone5 iPhone4S iPhone4 iTouch 4 iTouch 5 The iOS version of these devices should be V5.0 or later. IMPORTANT: Any individual who may be pregnant, has a pacemaker, suffers from diabetes, phlebitis and/or thrombosis, is at an increased risk of developing blood clots, or who has pins/screws/artificial joints or other medical devices implanted in his/her body should consult with a physician before using a massaging device designed for home use. Safety information To reduce the risk of electric shock, this product outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a proper outlet. Do not attempt to bypass this safety feature in any way. Do not use it an hour before and after mealtime as this may have adverse effects on the user. The massager is not intended for persons (including infant and children) with reduced physical, sensory or mental capabilities or with the lack of experience and knowledge-unless or for sleeping person. Do not operate the massager under the following conditions: Where aerosol products are being used or oxygen is being administered. Where explosive and /or flammable fumes is present Excessively humid or dusty environment such as bathroom Where the temperature is 40 centigrade or higher Do not expose the massager to heaters, stoves or direct sunlight. Remove all scarves, neckties, necklaces, and jewelry before using this massager. Avoid using it under the influence of alcohol or when you are not feeling well. Close supervision is necessary when the massager is near children, invalids, or disabled persons. If you are under medication or with medical conditions, please consult your doctor before use. Do not use the massager if you are not feeling well. Do not use outdoors. This massager is intended for household and indoor use only. If you use it in a cold room, do not increase the room temperature abruptly. It is recommended that you increase the temperature gradually. If it is brought into a warm environment from a cold place where it was stored, wait for one hour before use as there may be water droplets on mechanical parts due to condensation. Using it under such condition may result in malfunction. INSTRUCTION FOR USE Use the BodyRhythm without iOS device Step 1 Preparation Connect the power plug to the electrical outlet Place the BodyRhythm on the shoulder and zip it on Step 2 Start the BodyRhythm program Press the ‘Start/Stop’ button to start/stop program Press the ‘Mode’ button to adjust intensity of your desired level Press the ‘Intensity Level Down’ or ‘Intensity Level Up’ button to choose your desired massage program Use the BodyRhythm withiOS device Step1 Preparation Connect the power plug to the electrical outlet Step2 Set up procedures Place the BodyRhythm on the shoulder and zip it on Download the Free BodyRhythm App Prior to first use, download and install the BodyRhythm App from the App Store. Use keyword search terms ‘BodyRhythm’, ‘iMusic’. Or scan the 2D barcode on the package. Account Set Up and Registration Follow the on-screen instructions to register and set up your personal account. Connect to iOS Device via Bluetooth Turn Bluetooth “On” under the “Settings” Menu (Settings->General->Bluetooth->On).Wait until the model name printed on the monitor, (i.e. “BodyRhythm”) and “Not Paired” appear in the Bluetooth Menu,and select the model name to pair and connect. The control panel on BodyRhythm is invalid Open the BodyRhythm App and follow the on when it is connected to iOS device. screen instructions on App Note: For your maximum safety and comfort, the BodyRhythm are equipped with overheating protection circuit. After 30 minutes of usage, the units switch off automatically. Attention: You can stop the measurement process at any time by pressing the “START/STOP” button or unplug the Power Cord from the DC Jack. SAFTY INFORMATION Do not overload the electrical outlet. Use only the power source as indicated. Do not use it when your body is wet. Do not use wet hands to operate the BodyRhythm, orconnect or disconnect the power plug from the electrical outlet Do not tamper with the power cord or use it with a damaged cord as this may result in malfunction and an electric shock. Do not use the BodyRhythm with other therapeutic equipment or electric blanket, etc. Do not apply BodyRhythm knobs directly on head, joint of elbows and knees, breasts or abdomen. Never remove the plug from the outlet by pulling the power cord, but the plug. Do not use attachments not recommended by the manufacturer. • • • • • • • Do not operate the BodyRhythm under a blanket, pillow or any other covers.This may result in a rise in motor temperature and subsequent malfunction or fire. Do not place the power cord under heavy objects. Do not operate the BodyRhythm with the air openings blocked. Keep the air openings free of lint, hair and the like. Do not perform continuous program on the same spot of your body for more than 5 minutes at a time as this may result in excessive stimulation and adverse effects. Do not use it if the electrical outlet is loose. Do not share the BodyRhythm with others to avoid to cross-infection or allergy. Switch off immediately and disconnect the power cord from the electrical outlet, when: Water is accidentally spilled onto the BodyRhythm. This may result in electric shock. The massager fell into water. Fabric cover is torn and the internal components are exposed. Abnormal or severe pain is felt during tapping. Stop usage immediately and consult your doctor. Detection of any malfunction or any other abnormal condition during operation Power failure. Injury may occur then power is restored unexpectedly. Lightning storm. The BodyRhythm should never be left unattended when plugged in. Unplug from the outlet when not in use. Always unplug the BodyRhythm from the electrical outlet, before putting on, after using and before cleaning. Use the BodyRhythm only for its intended use as described in this manual. To disconnect, set all controls to the off position, then remove plug from the outlet. SPECIFICATONS Specifications Product name: BodyRhythm Model Number: MB3 Voltage Available & Power Consumption: Auto Timer: Wireless communication: Bluetooth 3.0 Environment temperature for operation: Environment humidity for operation: Environment temperature for storage and transport: Environment humidity for storage and transport: Gross Weight: 5.1 Pounds TROUBLESHOOTING If you encounter problems with the operation of the Music Massager, please check the following points to see if they can be rectified. If it still malfunctions or does not work, please turn off the music massager and remove the power plug from the electrical outlet. Do not attempt to fix it yourself. Return the appliance to a service center for examination and repair. Problem The massager does not work. Possible Cause Solution Power plug is not securely connected to the Check the power plug to ensure it is electrical outlet securely connected to the electrical outlet Electrical outlet is switched off Switch on the electrical outlet The auto timer function of 30 minutes may have Start again lapsed. The overheat protection device may have been Turn off the Switch and unplug the activated. electrical outlet to cool down the music massager. Unsuccessful Bluetooth on iOS device is switched off. connection Switch on the Bluetooch on iOS device between iOS The BodyRhythm is abnormal, or Bluethooth device and connection is abnormal. • Check if the BodyRhythm is switched on and within the BodyRhythm Bluetooth communication range (5 meters). • Check if other iOS device is connected to the BodyRhythm. If yes, disconnect it. • Ignore the Bodythm in Bluetooth list, search it again and connect it. CARE AND MAINTENANCE Unplug the power from the electrical outlet when not in use. Keep the massager in dry, shadow and safe places Make sure that the power plug is disconnected from the electrical outlet. Use only soft clean cloth to wipe off dust and dirt. Do not use abrasive cleaning agents to clean the BodyRhythm Do not use a damp cloth to clean the control panel. Note: The expected useful life of the BodyRhythm is 3 years or 5000 times. Do not remove cover; there are no serviceable parts inside. Do not expose this massager to rain or moisture. Do not expose the massager to heaters, stoves or direct sunlight. Do not place or store the massager where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. Do not insert any object or flammable material into it. This may result in electric shock, malfunction or risk of fire. Do not place the BodyRhythm where children can easily reach Do not attempt to disassemble the BodyRhythm. Do not use pins or other metallic fasteners with this appliance. (P) Do not wind the power cord around it. Do not crush or fold this massager when storing. Keep the cord away from heated surfaces. Do not carry this massager by its power supply cord or use the cord as a handle. WARRANTY INFORMATION The iMusicBodyRhythm is warranted to be free from defects inmaterials and workmanship within one year from the date of purchase when used in accordance with the provided instructions. The warranty extends only to the end user. We will, at our option, repair or replace without charge the iMusicBodyRhythm covered by the warranty. Repair or replacement is our only responsibility and your only remedy under the warranty. EXPLANATION OF SYMBOLS Symbol for” THE OPERATION GUIDE MUST BE READ” The sign background colour: blue The sign graphical symbol: white Symbol for “WARNING” Symbol for "GENERAL PROHIBITION SIGN" Symbol for “TYPE BF APPLIED PARTS” (the main part is the applied parts) Symbol for “CLASS II equipment“ Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local Authority or retailer for recycling advice”. Symbol for “MANUFACTURER” Symbol for “DATE OF MANUFACTURE” Symbol for “SERIAL NUMBER” EC REP for “EUROPEAN REPRESENTATIVE” 47Symbol Spenlow House Bermondsey London SE16 4SJ Symbol for “KEEP DRY” iMusic is a trademark of iCess Lab Inc. “Made for iPod” and “Made for iPhone” mean that an electronic accessory has been designed to connect specifically to iPod, or iPhonerespectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, or iPhone may affect wireless performance. iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by iCess Lab Inc. is under license. Other trademarks and trade names are those of their respective owners. IMPORTANT INFORMATION REQUIRED BY THE FCC This device complies with Part 15 of the FCC Rules. Its operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by iCess Lab Inc. would void the user’s authority to operate the product. Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If this product does causeharmful interference to radio or television reception, which can be determined by turning theequipment off and on, the user is encouraged to try to correct the interference by one or more ofthe following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver isconnected. —Consult the dealer or an experienced radio/TV technician for help. FCC ID: ZRYMB3 OTHER STANDARDS AND COMPLIANCES The Neck and Shoulder Massager corresponds to the following standards: IEC 60601-1:2006 (Medical electrical equipment – Part 1: General requirements for basic safety and essential performance); IEC 60601-1-2:2007 (Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral Standard: Electromagnetic compatibility–Requirements and tests); IEC 60601-1-6:2006 (Medical electrical equipment – Part 1-6: General requirements for basic safety and essential performance – Collateral Standard: Usability); IEC 60601-1-11:2010 (Medical electrical equipment – Part 1-11: General requirements for basic safety and essential performance– Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment) ELECTROMAGNETIC COMPATIBILITY INFORMATION Table 1 For all ME EQUIPMENT and ME SYSTEMS Guidance and manufacture’s declaration - electromagnetic emissions The Neck and Shoulder Massageris intended for use in the electromagnetic environment specified below. The customer or the user of the monitor should assure that it is used in such an environment. Emissions test Compliance RF emissions Electromagnetic environment - guidance The Neck and Shoulder Massager uses RF energy only for its internal function. Therefore, its RF Group 1 CISPR 11 emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions Class B CISPR 11 The monitor is suitable for use in all establishments, including domestic establishments and those Harmonic emissions Class A directly connected to the public low-voltage powersupply network that supplies buildings used for IEC 61000-3-2 domestic purposes. Voltage fluctuations/flicker emissions Complies IEC 61000-3-3 Table 2 For all ME EQUIPMENT and ME SYSTEMS Guidance and manufacturer’s declaration - electromagnetic immunity The Neck and Shoulder Massager is intended for use in the electromagnetic environment specified below. The customer or the user of the Neck and Shoulder Massager should assure that it is used in such an environment. IMMUNITY test IEC 60601test level Compliance level Electrostatic discharge (ESD) ± 6 kV contact ± 6 kV contact IEC 61000-4-2 ± 8 kV air ± 8 kV air Electromagnetic environment - guidance Floors should be wood, concrete or ceramic tile. Iffloors are covered with synthetic material, therelative humidity should be at least 30 %. Electrical fast transient/burst Mains power quality should be that of a typical ± 2 kV for power supply lines ± 2 kV for powersupply lines Surge ± 1 kV line(s) toline(s) ± 1 kV line(s) toline(s) Mains power quality should be that of a IEC 61000-4-5 ± 2 kV line(s) to earth ± 2 kV line(s) to earth typicalcommercial or hospital environment. <5 % UT(>95 % dip in UT) <5 % UT(>95 % dip in UT) IEC 61000-4-4 commercial or hospital environment. for 0.5 cycle for 0.5 cycle Mains power quality should be that of a typical Voltage dips, shortinterruptions 40 % UT(60 % dip in UT) 40 % UT(60 % dip in UT) commercial or hospital environment. If the user of and voltage variations on power for 5 cycles for 5 cycles the monitor requires continued operation during supply input lines 70 % UT(30 % dip in UT) 70 % UT(30 % dip in UT) power mains interruptions, it is recommended thatthe IEC 61000-4-11 for 25 cycles for 25 cycles monitor be powered from an uninterruptiblepower <5 % UT(>95 % dip in UT) <5 % UT(>95 % dip in UT) supply or a battery. for 5 s for 5 s Power frequency(50/60 Hz) magnetic field Power frequency magnetic fields should be at 3 A/m 3 A/m IEC 61000-4-8 levels characteristic of a typical location in a typicalcommercial or hospital environment. Note: UT is the a.c. mains voltage prior to application of the test level. Table 3 For ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacturer’s declaration - electromagnetic immunity The Neck and Shoulder Massager is intended for use in the electromagnetic environment specified below. Thecustomer or the user of the Neck and Shoulder Massager should assure that it is used in such an environment. IMMUNITY test IEC 60601 test level Compliance level Electromagnetic environment - guidance Conducted RF 3 Vrms 150 3V Portable and mobile RF communications equipmentshould be used no closer to IEC 61000-4-6 kHz to 80 MHz 3 V/m any part of the monitor,including cables, than the recommended Radiated RF 3 V/m 80 MHz separationdistance calculated from the equation applicable to thefrequency of IEC 61000-4-3 to 2.5 GHz the transmitter. Recommended separation distance: d 1.2 P d 1.2 P 80 MHz to 800 MHz d 2.3 P 800 MHz to 2.5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separationdistance in meters (m). Field strengths from fixed RF transmitters, as determined byan electromagnetic site survey, a should be less than thecompliance level in each frequency range. Interference may occur in the vicinity of equipmentmarked with the following symbol: Note 1 At 80 MHz and 800 MHz, the higher frequency range applies. Note 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the monitor is used exceeds the applicable RF compliance level above, the monitor should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the monitor. b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Table 4 For ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the Neck and Shoulder Massager The Neck and Shoulder Massager is intended for use in an electromagnetic environment in which radiated RF disturbancesare controlled. The customer or the user of the Neck and Shoulder Massager can help prevent electromagnetic interferenceby maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the monitor asrecommended below, according to the maximum output power of the communications equipment. Rated maximum output Separation distance according to frequency of transmitter power of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2,5 GHz d 1.2ඥ d 1.2ඥ d 2.3ඥ 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distanced in meters (m) can be determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Note 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Service Center iCess Labs, Inc. 723 N shoreline Blvd., Mountain View, CA 94043, U.S.A 1-855-816-7705 www.iMusicBodyRhythm.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 14 Producer : GPL Ghostscript 8.64 Create Date : 2012:12:28 15:34:21+08:00 Modify Date : 2012:12:28 15:34:21+08:00 Title : Microsoft Word - MB3 User Manual.docx Creator : PScript5.dll Version 5.2.2 Author : Zenger_ZhangEXIF Metadata provided by EXIF.tools