Andrew Wireless Innovations Group RPT-MR701 REPEATER User Manual M0062A0B

Andrew Wireless Innovations Group REPEATER M0062A0B

Software manual

REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 16-Apr-99REP1009V1.xx ( Id.-No. 147127 )Software manualfor band/channel selective RepeaterCopyright  MIKOM, Buchdorf 1998All rights reserved.No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or byany means, electronical, mechanical photocopying,recording or otherwise, without prior written permission of thepublisher.Author: Approved: QA:
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 211.12.98Table of contentsLIST OF UNIT SPECIFIC ABBREVIATIONS 41INTRODUCTION 52INSTALLATION 63SOFTWARE DOWNLOAD 73.1 Download procedure in local mode73.1.1 Download procedure in local mode, software controlled: 73.1.2 Download procedure in local mode, manually controlled: 84RUNNING THE SOFTWARE 104.1 Via PC or Laptop as terminal 104.2 Via modem 124.2.1 PSTN modem 124.2.2 Siemens M1 modem for GSM900 144.2.3 Motorola mobile ( CELLect1 card ) 145DESCRIPTION OF THE COMMANDS 155.1 Instruction modes 155.2 Conventions 155.3 Description of SET commands 165.3.1 SET ALARMMASK, definition of the severity level for an alarm 175.3.2 SET ALCTHR, setting of the ALC threshold 185.3.3 SET ALIAS*, enter name strings for external alarms 1 ... 4 195.3.4 SET ATT, sets attenuation  in uplink or downlink path 195.3.5 SET BAUD, definition of baudrate used 195.3.6 SET CF, setting of the center frequency 205.3.7 SET CFO, setting of the frequency offset 205.3.8 SET DIALMETH, setting of the dialing method 205.3.9 SET ID, Repeater identification 205.3.10 SET ILA, definition of a limit for invalid login attempts 215.3.11 SET INITSTR, definition of a initialisation string 215.3.12 SET LMT, to change timeout for local maintenance interface 215.3.13 SET LOGIC, definition of the I/O port logic for the external alarms 225.3.14 SET NUM, definition of 2 phone numbers used for the automatic dial out 225.3.15 SET PAR, definition of parity 225.3.16 SET PWD, to change password 225.3.17 SET PWRDOWN, to switch off band modules 235.3.18 SET REP, definition of waiting time between alarm call trials 235.3.19 SET TIME, to change actual time and date 245.3.20 SET UID, changes user identification 24
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 311.12.985.4 Description of the GET commands 255.4.1 GET ALARMMASK, displays the set severity level for an alarm 275.4.2 GET ALCTHR, displays the set value for the ALC threshold 275.4.3 GET ALIAS*, name strings for external alarms 275.4.4 GET ATT, gain setting 285.4.5 GET BAUD, baudrate 285.4.6 GET CF, set centre frequency in the GSM900 / GSM1800 band 285.4.7 GET CFO, frequency offset 295.4.8 GET ID, Repeater identification 295.4.9 GET ILA, displays stored number of invalid login attempts 295.4.10 GET INITSTR, displays the string which is used to initialize the modem 295.4.11 GET LMT, timeout for local interface 305.4.12 GET LOGIC, displays the logic of the I/O ports 305.4.13 GET NUM, displays stored  phone numbers 305.4.14 GET PAR, modem parity 305.4.15 GET PWRDOWN, displays power down status of the modules 305.4.16 GET REP, defines waiting time between trials for automatic alarm call 315.4.17 GET TIME, to get the actual time and date 315.5 Status commands 325.5.1 STATUS ALC, displays the actual status 335.5.2 STATUS AMPBIAS, current consumption of the RF modules 335.5.3 STATUS DOOR, door open / closed 335.5.4 STATUS HIST, list of all occurred alarms 335.5.5 STATUS I2C , displays the status of the I²C bus 355.5.6 STATUS LBATT, response information about Lithium battery 355.5.7 STATUS PWR, status of the power supplies 355.5.8 STATUS SYNTH, modules in operation 355.5.9 STATUS TEMP, temperature 365.6 Optional status commands 375.6.1 STATUS ACCU, response voltage value of backup battery 375.6.2 STATUS EXTALARM, status of external alarms 375.6.3 STATUS VSWR, displays the DL antenna VSWR 375.7 Action commands 385.7.1 ALARMACKN, acknowledgement of all alarms. 385.7.2 BYE, disconnect Repeater from telephone line in remote mode 385.7.3 BYE, disconnect Repeater from local maintenance interface 395.7.4 DNLOAD, starts software download 395.7.5 VER, displays the version of software and hardware 395.8 Optional action commands 405.8.1 ACCUDIS, starts discharge of accumulator 405.8.2 STOPDIS, stops battery discharging immediately 405.9 Error messages 415.9.1 SYNTAX ERROR 415.9.2 VALUE ERROR415.9.3 I²C-BUS ERROR 415.10 Features 416INDEX 42
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 411.12.98LIST OF UNIT SPECIFIC ABBREVIATIONSALC Automatic Level ControlDL DownlinkEEPROM Electrical erasable programming read only memoryI²C-Bus Inter Integrated Circuit BusLMT Local Maintenance TerminalMR Mikom RepeaterOMC Operation and Maintenance CenterRF Radio FrequencyRSSI Receive Signal Strength IndicationUL UplinkUPS Uninterruptable Power SupplyVSWR Voltage Standing Wave Ratio
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 511.12.981 IntroductionThis manual describes the functions of the standard software REP1009V1.xx implemented inband/channel selective Repeaters of the second generation. These Repeaters can be set locallyor remotely. A PCMCIA slot for modem operation is available. The design of the Repeatercomprises a large number of functions which the operator may monitor via terminal emulationprogram or the MIKOM OMC software platform. An easy to understand and easy to learncommunication language supports the operator to query status reports from the Repeater or tochange settings.Your Repeater is equipped with the required software which enables the operator tocommunicate with the microprocessor of the control module.The communication with the microprocessor of the control module is realized with a VT100compatible dialogue.The software is accessible in two different ways.n Locallyn RemotelyBoth possibilities are described below.• The communication can be done locally by connecting a Laptop or a PC with VT100emulation or a VT100 terminal via the control cable.Required equipment: - Laptop or PC with terminal program, e.g. PROCOMM- one serial RS232 cable: SUB-D9 (female) to SUB-D9 (female)Laptop or PCwith terminal programfigure 1-1 Repeater locally controlled
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 611.12.98• Furthermore the communication can be realized remotely via modem.figure 1-2 Repeater remotely controlled2 InstallationThe actual software version is part of the delivery schedule of your Repeater unit and will beinstalled in factory.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 711.12.983 Software downloadIt might be necessary to download another software version. This can be realized in twodifferent ways.n Software download in local moden Software download in remote mode 3.1 Download procedure in local modeTwo different download procedures exist in local mode. The software download software ormanually controlled. After a software download previous user settings ( data default values )might be overwritten. Before you start a software download save the set values for:n attenuationn ALC threshold 3.1.1 Download procedure in local mode, software controlled:Required equipment: - PC with terminal program, e.g. PROCOMM- one serial RS232 cable: SUB-D9 (female) to SUB-D9 (female)1. Check the position of DIP-Switch 4 ( position OFF ) on the control module.  figure 3-1 Position of DIP-Switch 41. Switch on Repeater and PC and connect control cable. Wait until the boot process is finished.2. Start Repeater software and login by typing ‘User-ID1’ and ‘P-word1’.3. Type software command: Syntax: DNLOAD ↵ 4. Exit terminal program immediately. OFF ONDIP-Switch 4
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 811.12.985. To start upload procedure type:  Syntax: upload 1 ↵ or      upload 2 ↵      depending on which serial interface is available ( COM 1 or COM 2 ).6. The copy procedure is running. You will be asked to continue by pressing any key. Now thesoftware download is in progress. The download lasts approximately 1 minute.7. Software boot starts automatically.Response: ‘MIKOM REPEATER MRx01A - SM2009 - SW:REP1009V1.xx’   ENTER <.> <CR> TO LOGIN3.1.2 Download procedure in local mode, manually controlled:Required equipment: - PC or Laptop- one serial RS232 cable: SUB-D9 (female) to SUB-D9 (female)1. Set the DIP-Switch 4 to position ON on the control module.  figure 3-2 Position of DIP-Switch 4  1. To start upload procedure type:  Syntax: upload 1 ↵ or      upload 2 ↵  depending on which serial interface is available ( COM 1 or COM 2 ). OFF ONDIP-Switch 4
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 911.12.982. The copy procedure is running. You will be asked to continue by pressing any key. Now thesoftware download is in progress. The download lasts approximately 5 minutes in localmode.3. Software boot starts automatically.4. Don’t forget to switch back the DIP-Switch 4  to position OFF.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 10 11.12.984 Running the software4.1 Via PC or Laptop as terminalThe local mode for settings via PC has to be set. Therefore the DIP-Switch 2 has to be atposition OFF.figure 4-1 DIP-Switch 2 for local modeF Note: Only if a Modem M1 is used DIP-Switch 2 has to be set.A VT100 terminal or a PC with VT100 emulation can be connected to the control moduleSM2009 by a standard RS232 cable, if necessary in connection with an adapter 9 to 25. PC or Laptop               -                         Control Module SM20099 contact SUB - D- Connector 9 contact SUB - D- Connectormale male   PC RS 232PIN           PIN1  )                                                                        (  12  )                                                                        (  23  )                                                                        (  34  )                                                                        (  45  )                                                                        (  56  )                                                                         (  67  )                                                                        (  78  )                                                                        (  89  )                                                                          (  9figure 4-2 Cable connectionThe following communication mode between control module and VT100 is set initially. OFF ON
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 11 11.12.98 9600 baud - 8 bit - no parity -1 stopbitThese settings can only be changed after connection of the terminal. If all wanted settings havebeen initialized and a modem has to be used it will be recommended to check whether thesettings comply with the capabilities of the modem and the line. Modifications are possible bysoftware commands.F Note: Settings on the Repeater can be performed after the following procedureonly.After connecting the PC to the Repeater, following procedure is necessary to get access to theprogram.MIKOM REPEATER MRx01A - SM2009 - SW: REP1009V1.xxENTER <.> <CR>1. Step:                  Type the two keys ( . ) FULLSTOP and (↵) ENTERYou have to type the keys:2. Step:                  ENTER USER IDYou have to enter: UserID1 ↵F Note: The input is case sensitive, no blanks. After three mistrial followsdisconnection.3. Step:                  ENTER PASSWORDYou have to enter: P-word1 ↵F Note: The input is case sensitive, no blanks. After three mistrials followsdisconnection. ↵↵.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 12 11.12.984.2 Via modemThe Repeater will be delivered with a preset init string. This init string was used for internaltests. In case no connection can be established check the local conditions and change the initstring if necessary.Three different modem types are available• PSTN modem ( DigiTel 34P ), line modem• Siemens M1 for GSM900, wireless modem• Motorola for GSM900 or GSM1800, wireless modem The following list contains the description of the AT commands:&F Sets modem to factory configurationE0 Echo OFFS0=1 Auto answer ON; the GSM module / M1 modem goes off-hook after the first ringing signal.S7=60 Waiting time for connection after dialing; permissible valuesare from 0 ... 60.B13 Setting to 9600 bps asynchronous mode\ N6 Auto reliable operation\ N0 Standard operation, no error correction+CBST=7,0,1 Set bearer service type to 9600 bps. Non-transparentconnection ( uses RLP )X3 Not waiting for dial tone; usually used at PABX.*P1 Switch ON phone&K4 Enables XON / XOFF flow controlTable 4.2-1 List of AT commands4.2.1 PSTN modemA Hayes compatible PSTN modem can be connected to the control module SM 2009 by thecontrol cable, which is subject of the delivery schedule.The init string for the PSTN modem is:AT&F X3 E0 S0=2
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 13 11.12.98control module SM2009      -      cable connection modem       PCMCIAfigure 4-3  Connection of control module and PSTN modemThe following communication mode between control module and VT100 is initially set for theuse of a Hayes-compatible modem.9600 baud - 8 bit - no parity -1 stopbitThese settings can only be changed after connection of the terminal. If a different modem hasto be used or if the quality of the line does not allow to use the set parameters, the settingshave to be changed in PC mode. This is the same for all other parameters, which can be setpreviously for modem mode by software.F Note: Settings on the Repeater can be performed after the following procedureonly.After connection to the Repeater following response appears on screen:1. Step:                  ENTER USER IDResponse on the screen: ENTER USER ID:------You have to enter: UserID1 ↵F Note: The input is case sensitive, no blanks. After three mistrial followsdisconnection.2. Step:                  ENTER PASSWORDResponse on the screen: ENTER PASSWORD:--------You have to enter: P-word1 ↵F Note: The input is case sensitive, no blanks. After three mistrials followsdisconnection.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 14 11.12.984.2.2 Siemens M1 modem for GSM900The Siemens M1 modem can be connected to the control module SM 2009 by the controlcable, which is subject of the delivery schedule.If an individual antenna of a wireless modem is required, the antenna cable may be fed througha watertight grommet at the connector panel of the housing.The init string for the Siemens M1 modem is ( without reset circuit )AT E0 S0=1 B13 S7=60 \N6The init string for the Siemens M1 modem has to be set by PC / Laptop ( with reset circuit )AT E0 S0=1 B13 S7=60 \N6 &WThis is the standard init string. If no connection can be established check the local conditionsand change the init string if necessary.4.2.3 Motorola mobile ( CELLect1 card )The Motorola mobile ( Dual band ) together with the CELLect1 card can be connected to thecontrol module SM 2009 by the control cable, which is subject of the delivery schedule.If an individual antenna of a wireless modem is required, the antenna cable may be fed througha watertight grommet at the connector panel of the housing.The init string for the Motorola module is:AT&F &K4 E0 S0=2 *P1 \N0+CBST=7,0,1
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 15 11.12.985 Description of the commandsAll available software commands are described in the following chapter.5.1 Instruction modesThere are four different types of commands:-  SET  commands - to change variable parameters-  GET  commands  - to ask status of variable parameters-  STATUS commands - to ask status of fixed parameters-  ACTION commands  - to perform certain actions5.2 ConventionsThe instruction is written in capital letters followed by selections in square brackets to beentered.SET NUM [x] [number] ↵↵The selections can be entered directly following the instruction e.g. SET NUM, but in caseonly SET NUM has been entered the computer queries for the missing information in aninteractive dialogue. As an example, x can be substituted by 1 or 2 corresponding to thewanted position in the telephone list and number can be substituted by the telephone number,which may consists of up to 25 characters.↵↵  stands for carriage return. It indicates to press the return key. If, in the above example, thetelephone number 2716 with priority 2 has to be entered the following command has to betyped:SET NUM 2 2716 ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 16 11.12.985.3 Description of SET commandsSET commands are used to set variable parameters. These parameters are stored non-volatilein an EEPROM.Table 5.3-1 presents a summary of SET commands.Command DescriptionSET ALARMMASK definition of the severity level for an alarmSET ALCTHR setting of the ALC thresholdSET ALIAS* alarm message name for external alarmsSET ATT attenuation in DL and UL pathSET BAUD definition of local interface baudrateSET CF sets the center frequency in UL and DLSET CFO sets frequency offset in UL and DLSET DIALMETH changes the dialing method pulse / toneSET ID Repeater identificationSET ILA sets the maximum value for invalid login attemptsSET INITSTR definition of string for initialisation of the modemSET LMT changes timeout of local interfaceSET LOGIC definition of the logic of I/O ports for external alarmsSET NUM two phone numbers for automatic dial outSET PAR definition of paritySET PWD changes passwordSET PWRDOWN switch off band/channel modulesSET REP definition of waiting time between alarm callsSET TIME changes date and timeSET UID changes user identification* Option Table 5.3-1 Summary of SET commandsIf a SET command has been entered not correctly SYNTAX ERROR or VALUE ERROR willbe returned depending on whether the erroneous input was due to an error in correct writingthe command or the erroneous input was a non-plausible value.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 17 11.12.985.3.1 SET ALARMMASK, definition of the severity level for an alarmSyntax: SET ALARMMASK ↵Response:ENTER ALARMMASKSTRING: ↵ENTER BAND MODULE (1-8) : ↵ENTER PERCEIVED SEVERITY(CRI,MAJ,MIN,WAR,DIS): ↵where the ALARMMASKSTRING must be one of the following stringsPWR-SUPPLY-MAINPWR-SUPPLY-8VPWR-SUPPLY-12VLITHIUM-BATTPASSWORDTEMPERATUREDOORSYNTH-LOCK-ULSYNTH-LOCK-DLALC-ULALC-DLCURRENT-AT-8VCURRENT-AT-12Vor if the corresponding option is activeACCU-VOLTAGE-L1ACCU-VOLTAGE-L2VSWREXT-ALARM-1EXT-ALARM-2EXT-ALARM-3EXT-ALARM-4For each alarmmask string it is also possible to set the severity level for all modules at the sametime.Syntax:  SET ALARMMASK-ALL ALC-UL CRI CRI CRI CRI CRI CRI CRI CRIWith this command it is possible to change the severity level for an alarm message. Theseverity level for an optional alarm can only be changed if the option is enabled. There will beno alarm message if the severity level has been set to DIS ( disabled ), or if the correspondingband/channel module has been switched off with the command SET PWRDOWN ENA.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 18 11.12.98The severity parameter defines five levels for an alarm message and can be set in the alarmmask. The severity levels indicate how the capability of the managed object has been affected.The levels are described below and are ordered from most severe to least severe:- Critical: The critical severity level indicates that a service affecting condition hasoccurred and an immediate corrective action is required to restore the capabilityof the managed object.- Major: The major severity level indicates that a service affecting condition hasdeveloped and an urgent corrective action is required. Such a severity can bereported, for example, when there is a severe degradation in the capability of themanaged object and its full capability must be restored.- Minor: The minor severity level indicates the existence of a non-service affecting faultcondition and that corrective actions should be taken in order to prevent a moreserious failure. Such a severity can be reported, for example, when the detectedalarm condition is not currently degrading the capability of the managed object.- Warning: The warning severity level indicates the detection of a potential or impendingservice affecting failure before any significant effect has been caused. Actionshould be taken to further diagnose and correction of the problem shall preventa more serious service affecting failure.- Disable: The disable severity level indicates that the detected failure has no influenceon the system and shall not be sent to the terminal.The alarm message for all status alarms will not be sent, if the alarm mask is set to DIS or themodule is deactivated with PWRDOWN ENA.5.3.2 SET ALCTHR, setting of the ALC thresholdWith this command it is possible to set the ALC threshold. The value for the ALC thresholdwill be determined in factory and can be found on a label on the RF modules. In case a secondmodule will be mounted or a module will be exchanged the values for the ALC threshold haveto be compared. If the modules have different values, the higher value must be set, due to thefact that the threshold can only be set for the whole Repeater.F Note: The higher ALC threshold value has to be set.Syntax: SET ALCTHR ↵Response: BAND-MODULE  ( 1/2  3/4  5/6  7/8 ): ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 19 11.12.98ENTER MODE (UL or DL) : ↵ENTER ALC THRESHOLD 0 - 255 : ↵* * * C A U T I O N * * *THE FOLLOWING ACTION MAY CAUSE DAMAGE TO EXTERNAL HARDWAREPRESS <Y> + <CR> TO PERFORM CHANGEAllowed values are binary digits 0 ... 255. Default value is 255.5.3.3 SET ALIAS*, enter name strings for external alarms 1 ... 4Syntax:SET ALIAS ↵Response: ENTER ENTRY - 1 TRU 4: ↵    ENTER ALARM ACTIVE NAME STRING -MAX 30 CHARS    : ↵    ENTER ALARM NON ACTIVE NAME STRING -MAX 30 CHARS: ↵You will be asked to enter a name string for the external alarms 1 ... 4. Two different namescan be defined, the first input is the name for the alarm active name and the second input is thename if the alarm is not active. Be aware the OMC needs appropriate key words forrecognising an alarm.5.3.4 SET ATT, sets attenuation  in uplink or downlink pathSyntax : SET ATT  ↵Response: ENTER BAND MODULE ( 1-8 ): ↵ENTER MODE ( UL or DL): ↵ENTER ATTENUATION: ↵You will be asked to enter the band module, mode and attenuation ( attenuation in dB, onlyvalues between 0 and 30 dB in steps of 2 dB ).5.3.5 SET BAUD, definition of baudrate usedSyntax: SET BAUD [ baudrate ] ↵Response: ENTER BAUDRATE – 1200, 2400, 4800 OR 9600:
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 20 11.12.98After first power on or change of battery a baudrate of 9600 is used.5.3.6 SET CF, setting of the center frequencySyntax: SET CF ↵Response: ENTER BAND MODULE (1-8): ↵ENTER CF UL <MHz>: ↵ENTER CF DL <MHz>: ↵The frequency can be set within the range of the GSM900 / GSM1800 band.5.3.7 SET CFO, setting of the frequency offsetSyntax: SET CFO ↵Response: ENTER BAND MODULE (1-8): ↵ENTER CFO UL <kHz>: ↵ENTER CFO DL <kHz>: ↵The frequency offset can be set in the range of +/- 1 MHz in steps of 10 kHz.5.3.8 SET DIALMETH, setting of the dialing methodSyntax: SET DIALMETH ↵Response: ENTER DIALING METHOD: T - TONE DIALING    P - PULSE DIALINGENTER CHOICE: ↵The default method is tone dialing.5.3.9 SET ID, Repeater identificationSyntax: SET ID ↵Response: ENTER ID STRING - MAX 25 CHARS: ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 21 11.12.98where Repeater ID may be max. 25 symbols. All characters between 21 H and 7E H will beaccepted.If you skip this request, the default Repeater identification appears:Response: Repeater ID:  MIKOM5.3.10 SET ILA, definition of a limit for invalid login attemptsSyntax: SET ILA ↵Response: ENTER VALUE : ↵The maximum allowed number of invalid login attempts have to be entered. Default value is 8.Setting range is 3 – 10  invalid login attempts.5.3.11 SET INITSTR, definition of a initialisation stringSyntax : SET INITSTR [Initstring] ↵Response: ENTER MODEM INIT STRING - MAX 60 CHARS: ↵where : [ Initstring ] is max. 60 symbols, 21 H to7E H is allowed.Initstring stands for the string stored in the modem for initialisation. It is defined in the manualof the modem.This stored INIT STRING was used for internal tests. In case no connection can be establishedcheck the local conditions and change the INIT STRING if necessaryF Note:  Use upper case characters for entry.5.3.12 SET LMT, to change timeout for local maintenance interfaceSyntax: SET LMT ↵Response: ENTER VALUE: ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 22 11.12.98Enter the local maintenance terminal timeout in minutes. LMT can be set in the range from 5 to99 minutes. Default value is 25 minutes.5.3.13 SET LOGIC, definition of the I/O port logic for the external alarmsWith this command it is possible to set the logic of the I/O ports for the external alarms. Thelogic can be changed for each alarm separately. The default settings of the I/O ports on thecontrol module are LLHH. This command is only available if the option “External Alarms” isactive.Syntax: SET LOGIC↵Response: ENTER ALARM LEVEL 1 (H/L): ↵ENTER ALARM LEVEL 2 (H/L): ↵ENTER ALARM LEVEL 3 (H/L): ↵ENTER ALARM LEVEL 4 (H/L): ↵5.3.14 SET NUM, definition of 2 phone numbers used for the automatic dial outSyntax: SET NUM ↵Response: ENTER ENTRY - 1 TRU 2: ↵ENTER PHONE NUMBER - MAX 25 CHARS: ↵Depending on the entry the numbers can have the priority 1 or 2 and  max. 25 symbols areallowed.5.3.15 SET PAR, definition of paritySyntax : SET PAR [ parameter ] ↵Response: SELECT PARAMETER:7 BITS ODD PARITY - 17 BITS EVEN PARITY  - 28 BITS NO PARITY - 3enter choice :After first power on or change of battery the interface module is preset to 8 Bits no parity.5.3.16 SET PWD, to change passwordSyntax: SET PWD ↵Response: ENTER ENTRY   -   1 TRU 4: ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 23 11.12.981 to 4 different passwords are possible. Users with password 1 or 2 have full access to theRepeater ( SET and GET commands possible). Users with password 3 or 4 have restrictedaccess ( only GET commands are available ).After typing this command you are requested to type the old password and finish with ↵.ENTER OLD PASSWORD: ----- ↵If the old password was correct you are requested to type the new password ( 1 - 10 symbolslong - letters, numbers, case sensitive ) and finish with ↵.ENTER NEW PASSWORD – MIN 1 MAX 10 CHARS: --------- ↵To store the new password the new password has to be typed again.ENTER NEW PASSWORD AGAIN TO CONFIRM : ---------- ↵PASSWORD HAS BEEN CHANGEDAfter first power on or change of batteries the default password ( to be determined for eachcustomer ) is used.5.3.17 SET PWRDOWN, to switch off band/channel modulesSyntax: SET PWRDOWN ↵Response: ENTER BAND MODULE ( 1-8 ): ↵SET POWER DOWN MODE: E - ENABLE POWER DOWN D - DISABLE POWER DOWNENTER CHOICE: ↵After typing the command you are asked to enter band module and the mode.Power down enable, means to switch off the band module.5.3.18 SET REP, definition of waiting time between alarm call trialsIf an alarm call is not acknowledged, the call will be repeated in time intervals, until it isacknowledged. The minimum value for the waiting time is 5 minutes.Syntax : SET REP [ cycle length ] ↵Response: ENTER CYCLE LENGTH IN MIN: ↵REP CYCLE: 10 MIN
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 24 11.12.98where : [ cycle length ] is the waiting time in minutes5 - 99 is allowed ( default: 10 min )5.3.19 SET TIME, to change actual time and dateSyntax: SET TIME ↵After carriage return the software queries line by line for the input as follows:ENTER YEAR < YYYY > (SKIP WITH CR):ENTER MONTH < MM > (SKIP WITH CR):ENTER DAY < DD > (SKIP WITH CR):ENTER HOURS < HH > (SKIP WITH CR):ENTER MINUTES < MM > (SKIP WITH CR):PRESS CR TO START5.3.20 SET UID, changes user identificationSyntax: SET UID ↵Response: ENTER ENTRY  -  1 TRU 4: ↵1 to 4 user identification terms are possible. Users with user ID 1 or 2 have full access to theRepeater ( SET and GET commands possible). Users with ID 3 or 4 have restricted access( only GET commands are available ).After typing this command you are requested to type the old UID and finish with ↵.ENTER OLD USER ID: ----- ↵If the old UID was correct you are requested to type the new UID and finish with ↵.ENTER NEW USER ID - MIN 1 MAX 10 CHARS:: --------- ↵To store the new UID type it again.ENTER NEW USER ID AGAIN TO CONFIRM : ---------- ↵USER ID HAS BEEN CHANGEDAfter first power on or changing of the Lithium battery the default password ( to bedetermined for each customer ) will be loaded.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 25 11.12.985.4 Description of the GET commandsGET commands are used to ask for the status of variable parameters.Table 5.4-1 presents a summary of GET commands.Command DescriptionGET ALARMMASK definition of the severity level for an alarmGET ALCTHR setting of the ALC thresholdGET ALIAS* displays all name strings of external alarmsGET ATT attenuation in DL and UL pathGET BAUD baudrate of the local interfaceGET CF lists center frequencies of 8 band modulesGET CFO frequency offsetGET DIALMETH information about dial method pulse / toneGET ID Repeater identificationGET ILA sets the maximum value for invalid login attemptsGET INITSTR initialisation string for the modemGET LMT timeout of the local interfaceGET LOGIC definition of the logic of I/O ports for external alarmsGET NUM two phone numbers for automatic dial outGET PAR parity ( communication parameter of the local interface )GET PWRDOWN displays state if a band module is powered downGET REP waiting time between alarm calls via modemGET TIME date and time of system* OptionTable 5.4-1 Summary of GET commandsIf a GET command has been entered not correctly, SYNTAX ERROR will be returned.By typing the GET command all status information are given. Due to the fact that the report isvery long the GET report can be split in two parts. You have to type GET1 to see the first partand GET2 to see the second part.In the following an example of a GET1 and a GET2 report is given.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 26 11.12.98figure 5-1 Example of a GET1 reportfigure 5-2 Example of a GET2 report
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 27 11.12.985.4.1 GET ALARMMASK, displays the set severity level for an alarmSyntax: GET ALARMMASK ↵Response:*** A L A R M M A S K ***PWR-SUPPLY-MAIN: CRIPWR-SUPPLY-8V  : CRIPWR-SUPPLY-12V : CRILITHIUM-BATT   : WARACCU-VOLTAGE-L1*: WARACCU-VOLTAGE-L2*: MINVSWR*           : MAJEXT-ALARM-1*    : WAREXT-ALARM-2*    : WAREXT-ALARM-3*    : WAREXT-ALARM-4*    : WARPASSWORD        : WARBAND-MODULE      1/2         3/4         5/6         7/8TEMPERATURE    : CRI         CRI         CRI         CRIDOOR           : WAR         WAR         WAR         WARBAND-MODULE       1     2     3     4     5     6     7     8SYNTH-LOCK-UL  : CRI   CRI   CRI   CRI   CRI   CRI   CRI   CRISYNTH-LOCK-DL  : CRI   CRI   CRI   CRI   CRI   CRI   CRI   CRIALC-UL         : CRI   CRI   CRI   CRI   CRI   CRI   CRI   CRIALC-DL         : CRI   CRI   CRI   CRI   CRI   CRI   CRI   CRICURRENT-AT-8V  : MAJ   MAJ   MAJ   MAJ   MAJ   MAJ   MAJ   MAJCURRENT-AT-12V : MAJ   MAJ   MAJ   MAJ   MAJ   MAJ   MAJ   MAJ* OptionalThe alarmmask string will only be displayed if the corresponding option is implemented.Depending on the system configuration the response might be different compared to theexample above.5.4.2 GET ALCTHR, displays the set value for the ALC thresholdSyntax: GET ALCTHR ↵Response: BAND-MODULE     1/2    3/4    5/6    7/8ALC THRESHOLD UL : 170ALC THRESHOLD DL : 2005.4.3 GET ALIAS*, name strings for external alarmsSyntax: GET ALIAS ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 28 11.12.98Response: NAME STRINGS FOR ALARMSEXT. ALARM 1     ACTIVE – EXT. ALARM 1 FAILUREEXT. ALARM 1 NON ACTIVE – EXT. ALARM 1 OKEXT. ALARM 2     ACTIVE – EXT. ALARM 2 FAILUREEXT. ALARM 2 NON ACTIVE – EXT. ALARM 2 OKEXT. ALARM 3     ACTIVE – EXT. ALARM 3 FAILUREEXT. ALARM 3 NON ACTIVE – EXT. ALARM 3 OKEXT. ALARM 4     ACTIVE – EXT. ALARM 4 FAILUREEXT. ALARM 4 NON ACTIVE – EXT. ALARM 4 OKor UPS ALARM ACTIVEUPS NON ACTIVEBATTERY VOLTAGE LOWBATTERY VOLTAGE OKUPS DOOR OPENUPS DOOR CLOSEDBATTERY DOOR OPENBATTERY DOOR CLOSED5.4.4 GET ATT, gain settingSyntax: GET ATT ↵Response:BAND-MODULE    1    2    3    4    5    6    7    8CF UL  [MHz] 833.5CF DL  [MHz] 947.5CFO UL [kHz] 0CFO DL [kHz] 0ATT UL [dB] 0ATT DL [dB] 4   5.4.5 GET BAUD, baudrateSyntax: GET BAUD ↵Response: LOCAL - INTERFACE : 9600 bps, 8 bits, NO PARITY( also 4800, 2400 or 1200 are possible)5.4.6 GET CF, set centre frequency in the GSM900 / GSM1800 bandSyntax: GET CF ↵Response, e.g. for the GSM900 system:
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 29 11.12.98BAND MODULE    1 2    3    4    5    6    7    8CF UL  [MHz] 833.5 0CF DL  [MHz] 880.5 0CFO UL [kHz] 0 0CFO DL [kHz] 0 0ATT UL [dB] 0 0ATT DL [dB] 4    05.4.7 GET CFO, frequency offsetSyntax: GET CFO ↵Response, e.g. for the GSM900 system:BAND MODULE    1    2    3    4    5    6    7    8CF UL  [MHz] 833.5  0CF DL  [MHz] 880.5  0CFO UL [kHz] 0 0CFO DL [kHz] 0 0ATT UL [dB] 0 0ATT DL [dB] 4    05.4.8 GET ID, Repeater identificationSyntax: GET ID ↵Response:  REPEATER ID: MIKOM5.4.9 GET ILA, displays stored number of invalid login attemptsSyntax: GET ILA ↵  Response: ILA Invalid login attempts:5.4.10 GET INITSTR, displays the string which is used to initialize the modemSyntax: GET INITSTR ↵Response: If a Hayes compatible modem is used:MODEM INITSTRING: AT&F &K4 E0 S0=2
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 30 11.12.985.4.11 GET LMT, timeout for local interfaceSyntax: GET LMT ↵Response: TIMEOUT FOR LMT : 25 min5.4.12 GET LOGIC, displays the logic of the I/O portsSyntax: GET LOGIC ↵Response: EXT. ALARM LEVEL: L L H H5.4.13 GET NUM, displays stored  phone numbersSyntax : GET NUM [ x ] ↵where: [ x ] is priority in the list, may be 1 or 2orSyntax: GET NUM ↵Response:  PHONE NUMBER 1: 0000PHONE NUMBER 2: 00005.4.14 GET PAR, modem paritySyntax: GET PAR ↵Response: LOCAL-INTERFACE : 9600 bps, 8 bits, NO PARITY5.4.15 GET PWRDOWN, displays power down status of the modulesSyntax:  GET PWRDOWN ↵Response: BAND-MODULE  1  2   3   4   5   6   7   8PWR DOWN MODE: ENA  DISThis command displays the status of the band modules.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 31 11.12.98If a module is switched off the response is ‘POWER DOWN MODE ENA’.If a module is switched on the response is ‘POWER DOWN MODE DIS’.5.4.16 GET REP, defines waiting time between trials for automatic alarm callSyntax: GET REP ↵Response: REP CYCLE : 10 min( Possible range is 5....99 min )5.4.17 GET TIME, to get the actual time and dateSyntax: GET TIME ↵Response: TIME : 13:30:20DATE : 02-12-98
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 32 11.12.985.5 Status commandsStatus commands are used to receive information about fixed parameters.Table 5.5-1 presents a summary of STATUS commands.Command DescriptionSTATUS ACCU* see chapter 5.6.1STATUS ALC ALC in DL and UL for each band moduleSTATUS AMPBIAS current consumption of the RF modulesSTATUS DOOR door open/ closedSTATUS EXTALARM * see chapter 5.6.2STATUS HIST history of alarmsSTATUS I2C status of the I²C busSTATUS LBATT Lithium batterySTATUS PWR power supplySTATUS SYNTH modules in operation / not in operationSTATUS TEMP actual temperature inside Repeater cabinetSTATUS VSWR * see chapter 5.6.3* Option Table 5.5-1 Summary of STATUS commandsBy typing STATUS commands all status information are given.figure 5-3 Example of a STATUS report
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 33 11.12.985.5.1 STATUS ALC, displays the actual statusSyntax: STATUS ALC ↵Response: BAND-MODULE 1 2   3   4   5   6   7   8ALC-UL   : OK   OKALC-DL   : OK   ALARM < CRI >If the Repeater exceeds the set ALC threshold an alarm will be released. The value for theALC threshold is written on a label on the conversion module. The alarm may have one of theseverity levels.5.5.2 STATUS AMPBIAS, current consumption of the RF modulesSyntax: STATUS AMPBIAS ↵Response: BAND-MODULE   1   2   3   4   5   6   7   8CURRENT-AT-8V :OK  OKCURRENT-AT-12V:OK  ALARM < CRI >Displays the status of the current consumption in the conversion modules. In case of a defectconversion module, the values might be too low or too high, which results in an alarmmessage. The alarm can have on of the severity levels5.5.3 STATUS DOOR, door open / closedSyntax: STATUS DOOR ↵Response : BAND MODULE  1/2    3/4    5/6     7/8DOOR :    OPEN < WAR >A DOOR OPEN condition results in an alarm message. The alarm may have one of the fiveseverity levels.5.5.4 STATUS HIST, list of all occurred alarmsSyntax: STATUS HIST ↵Response: HISTORY OF ALARMS:NO ALARMS STOREDIn the following example there is also a status hist listing depicted, after the alarms have beenacknowledged.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 34 11.12.98figure 5-4 Example of a STATUS HIST reportThe following table contains a list of all available alarm:NO. ALARM NAME ALARM ACTIVE STATUS1AMPLIFIER BIAS FAILURE2POWER SUPPLY 8 V FAILURE3POWER SUPPLY 12 V FAILURE4POWER SUPPLY MAINS FAILURE5SYNTH FAILURE6DOOR OPEN7VSWR** ALARM8ALC FAILURE9ACCU VOLTAGE** LOW10 LITHIUM BATTERY VOLTAGE LOW11 OVERTEMP FAILURE12 INVALID LOGIN ATTEMPT13 I2C BUS FAILURE14* EXT. ALARM 1** FAILURE15* EXT. ALARM 2** FAILURE16* EXT. ALARM 3** FAILURE17* EXT. ALARM 4** FAILURE*Alarms default settings, changeable by software instruction SET ALIAS** Only available if the option is active
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 35 11.12.985.5.5 STATUS I2C , displays the status of the I²C busSyntax: STATUS I2C ↵Response: I2C BUS OKor I2C BUS FAILURE < WAR >This alarm may have one of the possible severity levels. A defect ribbon cable between thecontrol module and the modules might be the cause for an I²C bus failure or if a Repeater wasdisconnected from mains.5.5.6 STATUS LBATT, response information about Lithium batterySyntax: STATUS LBATT ↵Response: LITHIUM BATTERY OKor LITHIUM BATTERY VOLTAGE TOO LOWIf the voltage of the Lithium battery is < 1 V, an alarm will be released.5.5.7 STATUS PWR, status of the power suppliesSyntax : STATUS PWR ↵Response: PWR-SUPPLY-8V     : OKPWR-SUPPLY-12V    : OKPWR-SUPPLY-MAINS  : OKIn case of power supply 12 Volts failure.Response: PWR-SUPPLY-12V   : FAILURE < WAR >If power is available the message is OK, if no power can be detected a failure will be displayed.5.5.8 STATUS SYNTH, modules in operationSyntax : STATUS SYNTH ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 36 11.12.98Response:  BAND-MODULE  1  2   3   4   5   6   7   8SYNTH-LOCK-UL: OK OKSYNTH-LOCK-DL: OK FAIL  < CRI >A defect synthesizer indicates that the conversion module has to be exchanged.5.5.9 STATUS TEMP, temperatureSyntax: STATUS TEMP ↵Response: BAND-MODULE    1/2   3/4   5/6   7/8TEMP [deg C] :  56In case 4 Repeaters are installed, the temperature will be displayed for each unit with aresolution of 1° C. The accuracy is ± 2° C.An alarm will be released at a temperature ≥ +75° CThe response then is: TEMPERATURE = 76 °C, Temperature Alarm - Stage 1Another alarm will be released at a temperature ≥ +90° C.The response then is: TEMPERATURE = 91 °C, Temperature Alarm - Stage 2RF stages are in POWER DOWN mode as long as the temperature alarm stage 2 exists andwill be switched on again if the temperature is below +85° C.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 37 11.12.985.6 Optional status commandsIn case of implementing optional modules like external alarms, battery backup module orVSWR following commands are available.5.6.1 STATUS ACCU, response voltage value of backup batterySyntax: STATUS ACCU ↵Response: ACCU-VOLTAGE-L1 :  OKACCU-VOLTAGE-L2 :  OKIf the voltage of the backup battery is < 7.7 V, a warning will be released ( L1 ).If the voltage of the backup battery is < 7.0 V, an alarm will be released ( L2 ).5.6.2 STATUS EXTALARM, status of external alarmsSyntax: STATUS EXTALARM ↵Response: EXT. ALARM 1 OKEXT. ALARM 2 OKEXT. ALARM 3 FAILURE < WAR >EXT. ALARM 4 FAILURE < WAR >5.6.3 STATUS VSWR, displays the DL antenna VSWRSyntax: STATUS VSWR ↵Response: VSWR : OKThe VSWR module measures the voltage standing wave ratio of the DL output antenna port.If the VSWR falls below approximately 10 dB an alarm is released.This enables the provider to know the status of the cable to the antenna. If a cable is defectivethe VSWR will decrease and the alarm will be released. The alarm can be forwarded to anOMC, so that faults and irregularities can be recognised and eliminated rather quick.The alarm has one of the severity levels ( DISable, WARning, MINor, MAJor, CRItical ).
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 38 11.12.985.7 Action commandsAction commands are used to perform a certain kind of action without an additional parameter.Table 5.7-1 presents a summary of action commands.Command DescriptionACCUDIS * starts to discharge the accumulator, see chapter 5.8.1ALARMACKN acknowledgement of all occurred alarmsBYE disconnect Repeater from telephone line in remote modeBYE disconnect Repeater from local maintenance interfaceDNLOAD starts software downloadSTOPDIS * stops to discharge the accumulator, see chapter 5.8.2VER revision number of software* Options Table 5.7-1 Summary of action commands5.7.1 ALARMACKN, acknowledgement of all alarms.Syntax: ALARMACKN ↵Response: ALARM ACKNOWLEDGEDEntered alarms in the alarm list can be acknowledged by simply ringing back a dn typingALARMACKN.Acknowledged alarms will be indicated in the STATUS HIST with ‘-ack’. As soon as thealarms have been acknowledged the alarm relay will be reset and the summary LEDs switch togreen light again. Additionally connected devices for alarm indication will be switched off withthis command. All data of the STATUS HIST are lost if the Repeater will be booted or if theRepeater was disconnected from mains.A new failure will be written immediately in the STATUS HIST.5.7.2 BYE, disconnect Repeater from telephone line in remote modeSyntax: BYE ↵5.7.3 BYE, disconnect Repeater from local maintenance interfaceSyntax: BYE ↵
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 39 11.12.98Response: LOGOUT FROM LOCAL MAINTENANCE INTERFACE5.7.4 DNLOAD, starts software downloadSyntax: DNLOAD ↵It is not possible to interrupt this process after typing the command DNLOAD. If there is noinput for about 1 minute the Repeater boots automatically.A separate documentation is available for the remote download procedure.Exit terminal program immediately.To start upload procedure type:Syntax: upload1.bat  orupload2.batdepending on which serial interface is available ( COM 1 or COM 2 ).5.7.5 VER, displays the version of software and hardwareSyntax : VER ↵Response:  HW MRx01A – SM2009 SW REP1009 V1.xx*actual version numberDisplays the hardware configuration ( control module SM2009 ) and the integrated softwareversion.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 40 11.12.985.8 Optional action commands5.8.1 ACCUDIS, starts discharge of accumulatorSyntax: ACCUDIS ↵Response: START DISCHARGE OF BACKUP BATTERYStarts to discharge the backup battery and stops automatically if the minimum voltage isreached.5.8.2 STOPDIS, stops battery discharging immediatelySyntax: STOPDIS ↵Response: BATTERY DISCHARGE STOPPEDStops the discharge of the backup battery immediately.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 41 11.12.985.9 Error messagesThere are two error messages resulting from erroneous inputs and one error message thatresults from hardware failure.5.9.1 SYNTAX ERRORThis error message will be returned if a command is written not correctly or if the writtencommand does not exist. The computer is ready for new inputs immediately.5.9.2 VALUE ERRORThis error message will be returned if a non-plausible value has been entered. Possibly, thevalue was out of the defined range, as e.g. in case of a negative number, or it was not in thedefined range of the character set as e.g. 19H in INIT STR.5.9.3 I²C-BUS ERRORThis error occurs if a part of the hardware has been damaged, e.g. the control module cannotget access to a synthesizer, because of a bad ribbon cable or an I²C-Bus slave ties the one lineof the bus to ground.5.10 Features1. By pressing the arrow keys ↑ or ↓, the last ten commands, stored in the command bufferwill be repeated forward and backward.2. To correct a typing error use backspace function as usual.3. After typing a command of an option which is not active, the response is “OPTION NOTACTIVE”.
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 42 11.12.986 IndexAAction commandsALARMACKN  39BYE  39DNLOAD  40VER  40AT commands  12CCommandsGET  26SET  16STATUS  33Communicationlocally  5remotely  6EError message  42ErrorsI²C-Bus  42Syntax error  42Value error  42GGainSettings via modem  12GET commandsGET ALARMMASK  28GET ALCTHR  28GET ALIAS*  29GET ATT  29GET BAUD  29GET CF  30GET CFO  30GET ID  30GET ILA  30GET INITSTR  31GET LMT  31GET LOGIC  31GET NUM  31GET PAR  31GET PWRDOWN  32GET REP  32GET TIME  32IInit stringfor Motorola modem  14for PSTN modem  12for Siemens M1 modem  14used in factory  12Installation  6LLogin procedurein modem mode  13MModem  11Modem types  12Motorola (Flare)  14PSTN  12Siemens M1  14OOptional action commandsACCUDIS  41STOPDIS  41RRepeating commands  42Running the softwarevia Laptop/PC  10via modem  12SSET commandsSET ALARMMASK  17SET ALCTHR  19SET ALIAS  19SET ATT  19SET BAUD  20SET CF  20SET CFO  20SET DIALMETH  20SET ID  21SET ILA  21SET INITSTR  21SET LMT  22SET LOGIC  22SET NUM  22SET PAR  22SET PWD  23SET PWRDOWN  23SET REP  24
REP1009V1.xxM0062A0B.doc Id.-No. 148964 Page 43 11.12.98SET TIME  24SET UID  24Severity levels  18Software download  7local mode  7STATUS commandsSTATUS ALC  34STATUS AMPBIAS  34STATUS DOOR  34STATUS HIST  34STATUS I2C  36STATUS LBATT  36STATUS PWR  36STATUS SYNTH  37STATUS TEMP  37STATUS commands, optionalSTATUS ACCU  38STATUS EXTALARM  38STATUS VSWR  38