Andrew Wireless Innovations Group RPT-MR703 Bi-Directional Amplifier for Small Area Indoor Coverage User Manual Update to manual
Andrew Wireless Innovations Group Bi-Directional Amplifier for Small Area Indoor Coverage Update to manual
Contents
- 1. User Manual
- 2. Appendix to user manual
- 3. Update to manual
Update to manual
WARNING INSTALLERS! This device must be installed so that while this device is in operation, a separation distance of at least 20 centimeters must be maintained between radiating antennas and the body of the user or nearby persons in order to meet the FCC RF exposure guidelines. Appendix A : Installation Checklist The following checklist provides a summary of the procedures for installing a MR703D system: Step Item/ Action MR703D Site Drawing Equipme nt List: MR703D AC Power Outlet Coverage Antenna* Donor Antenna 50-ohm Donor Antenna Cable 50-ohm Donor Jumper* 50-ohm Coverage Antenna Cable Installation tools: Cable connector Tools* Multimeter Handset with Power Indicator Calculate RF Output Power (ERP) at antennas for FCC RF exposure compliance.. Run Cable Attach Connectors* Verify “Donor and CoverageAntennas ” locations are consistant with RF exposure warning (see above and below). Record Serial Numbers and Locations on site Drawing. Mount the Equipment Connect the 50-ohm Cables as shown on the Site Plan 10 11 12 Supply AC Power, and commission the System. Check Power Levels Description Master copy of the site plan noting the MR703D location and serial number, and the location of the indoor coverage antenna(s)). This should characterize the design parameters for the system including cable paths and lengths. Quantity: Crimper, knife, etc. To ensure no cable shorts. To verify coverage after commissioning. Installer must verify that the Output Power at the antennas is less than 3W ERP, this must include cable loss and antenna gain. For additional information, contact Mikom technical support at (800)-800-7465 Install Cable in the site. Measure across center pin and outer shell (ground) to ensure no short. Be sure to record the antennas location status for future reference. Note: this is to aid the Mikom Technical Support Specialists, should you need their assistance. Including indoor coverage antennas for metal case models. Use caution when connecting semi-flexible cables to the mounted MR703D and antennas. Excessive force on antenna or MR703D connectors will result in serious equipment damage. Check the MR703D status as described in previous section . Check power indication of handheld mobile at various locations within the coverage area. * As Required WARNING INSTALLERS! This device must be installed so that while this device is in operation, a separation distance of at least 20 centimeters must be maintained between radiating antennas and the body of the user or nearby persons in order to meet the FCC RF exposure guidelines. Appendix A : Installation Checklist:MR703D Users Guide Manual 149678 (m0041a3a, 6\00) Page A-1 ♦
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2000:06:27 10:16:10 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2000:06:27 10:16:12-04:00 Page Count : 1EXIF Metadata provided by EXIF.tools