Andrew Wireless Innovations Group RPT-MR703 Bi-Directional Amplifier for Small Area Indoor Coverage User Manual Appendix to

Andrew Wireless Innovations Group Bi-Directional Amplifier for Small Area Indoor Coverage Appendix to

Contents

Appendix to user manual

Download: Andrew Wireless Innovations Group RPT-MR703 Bi-Directional Amplifier for Small Area Indoor Coverage User Manual Appendix to
Mirror Download [FCC.gov]Andrew Wireless Innovations Group RPT-MR703 Bi-Directional Amplifier for Small Area Indoor Coverage User Manual Appendix to
Document ID101847
Application IDoC5T5Nu/bJxlU1KHbgHYhg==
Document DescriptionAppendix to user manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize2.17kB (27137 bits)
Date Submitted2000-05-24 00:00:00
Date Available2000-07-10 00:00:00
Creation Date2000-05-24 13:04:35
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2000-05-24 13:04:36
Document TitleAppendix to user manual

WARNING! While this device is in operation, a separation distance of
at least 20 centimeters must be maintained between radiating antennas
and the body of the user or nearby persons in order to meet the FCC RF
exposure guidelines.
Appendix A : Installation Checklist
The following checklist provides a summary of the procedures for installing a MR703D system:
Step
Item/ Action
MR703D Site Drawing
Equipme nt List:
MR703D
AC Power Outlet
Coverage Antenna*
Donor Antenna
50-ohm Donor Antenna Cable
50-ohm Donor Jumper*
50-ohm Coverage Antenna Cable
Installation tools:
Cable connector Tools*
Multimeter
Handset with Power Indicator
Run Cable
Attach Connectors*
Verify “Donor and
CoverageAntennas ” locations are
consistant with RF exposure warning
(see above and below).
Record Serial Numbers and Locations
on site Drawing.
Mount the Equipment
Connect the 50-ohm Cables as shown
on the Site Plan
10
11
Supply AC Power, and commission
the System.
Check Power Levels
Description
Master copy of the site plan noting the MR703D location and
serial number, and the location of the indoor coverage
antenna(s)). This should characterize the design parameters
for the system including cable paths and lengths.
Quantity:
Crimper, knife, etc.
To ensure no cable shorts.
To verify coverage after commissioning.
Install Cable in the site.
Measure across center pin and outer shell (ground) to ensure
no short.
Be sure to record the antennas location status for future
reference.
Note: this is to aid the Mikom Technical Support Specialists,
should you need their assistance.
Including indoor coverage antennas for metal case models.
Use caution when connecting semi-flexible cables to the
mounted MR703D and antennas. Excessive force on antenna
or MR703D connectors will result in serious equipment
damage.
Check the MR703D status as described in previous section .
Check power indication of handheld mobile at various
locations within the coverage area.
* As Required
WARNING! While this device is in operation, a separation distance of
at least 20 centimeters must be maintained between radiating antennas
and the body of the user or nearby persons in order to meet the FCC RF
exposure guidelines.
Appendix A : Installation Checklist:MR703D Users Guide Manual 149678 (m0041a3a, 5\00)
Page A-1
♦

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes