Andrew Wireless Innovations Group RPT-MR801BI MR801BI Power and MR801BI SMR Band Repeater User Manual M0079A1A
Andrew Wireless Innovations Group MR801BI Power and MR801BI SMR Band Repeater M0079A1A
Contents
- 1. Users manual
- 2. Users manual update
Users manual
User’s manual for Repeater MRx01B Power User’s manual for band or channel selective Repeater MRx01B Power M0079A1A.doc Id.-No. 151775 Page 1 10-March-00 User’s manual for Repeater MRx01B Power Copyright MIKOM, Buchdorf 2000 All rights reserved. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. M0079A1A.doc Id.-No. 151775 Page 2 10-March-00 User’s manual for Repeater MRx01B Power Table of Contents LIST OF FIGURES AND TABLES LIST OF UNIT SPECIFIC ABBREVIATIONS CONTENTS OF DELIVERY HEALTH AND SAFETY WARNING PREAMBLE INTRODUCTION 11 1.1 Intended purpose 11 1.2 About the MRx01B Power 11 1.3 Modular design 11 1.4 Applications 12 FUNCTIONAL DESCRIPTION 13 2.1 General 13 2.2 Conversion modules 14 2.3 Mother board 14 2.4 Control module SM 2009 ( Rev. 07 and higher ) 16 2.5 Duplexer 20 2.6 Active combiner 21 2.7 Measuring aids 21 2.8 Feedforward amplifier 22 2.9 Power supply 22 3.1 FUNCTIONS AND FEATURES 24 Band and channel selectivity 24 M0079A1A.doc Id.-No. 151775 Page 3 10-March-00 User’s manual for Repeater MRx01B Power 3.2 Gain setting 24 3.3 ALC 25 3.4 CFO 25 3.5 BITE and alarms 3.5.1 Handling of alarms 3.5.2 Status report 3.5.3 Severity levels 25 27 28 28 29 OPTIONAL EQUIPMENT 4.1 VSWR module 29 4.2 External alarms 29 4.3 Modem 30 4.4 External RF output 31 4.5 Battery backup module 32 5.1 INSTALLATION 33 Mechanical installation 34 5.2 Electrical installation 5.2.1 Grounding 5.2.2 Power connection 5.2.3 Connection of the antenna cables 36 36 37 37 39 6.1 SETTING TO WORK Preparation 39 6.2 Setting of operational parameters 6.2.1 Manual settings by means of rotary switches 6.2.2 Setting of the attenuation 6.2.3 Settings via personal computer as terminal 6.2.4 Settings via modem 39 40 40 42 44 TROUBLE SHOOTING 45 7.1 Error indication 45 7.2 Alarm monitoring with the STATUS HIST command 45 M0079A1A.doc Id.-No. 151775 Page 4 10-March-00 User’s manual for Repeater MRx01B Power 7.3 Power supply 46 7.4 General remarks 46 MAINTENANCE 47 8.1 General 47 8.2 Replacement of the fuses (mains) 47 8.3 Replacement of the power supply fuse 48 8.4 Replacement of the mains cable 48 8.5 Replacement of the RAM / RTC battery 49 8.6 Replacement of the duplexers 50 8.7 Replacement of conversion modules 50 8.8 Replacement of the control module SM 2009 53 8.9 Replacement of power supplies 54 8.10 Replacement of active combiner modules 55 8.11 Replacement of feedforward amplifier 55 9.1 APPENDICES 58 Repeater specifications 58 9.2 Spare parts lists for MRx01B Power 9.2.1 Spare parts list for MR301B Power 9.2.2 Spare parts list for MR401B Power 9.2.3 Spare parts list for MR701B Power 9.2.4 Spare parts list for MR801B Power and MR801Bi Power 68 68 70 71 73 9.3 Installation drawing of the Repeater 75 9.4 Top view of the Repeater (left side , exemplary configuration) 76 9.5 Top view of the Repeater (right side, exemplary configuration) 77 9.6 One channel configuration – cabling and block diagram 78 10 INDEX M0079A1A.doc 80 Id.-No. 151775 Page 5 10-March-00 User’s manual for Repeater MRx01B Power LIST OF FIGURES AND TABLES table 1-1 List of international sales offices .............................................................................. 10 figure 2-1 Block diagram of MRx01B Power.......................................................................... 13 figure 2-2 Top view of a conversion module ........................................................................... 14 figure 2-3 Top view of a mother board .................................................................................... 15 figure 2-4 Configuration of the control module ( Rev.07 and higher ) .................................... 18 figure 2-5 Configuration of the DIP-Switches ......................................................................... 19 figure 2-6 Top view of the duplexers ....................................................................................... 20 figure 2-7 Top view of the active combiner module ................................................................ 21 figure 2-8 Top view of the feedforward amplifier ................................................................... 22 figure 2-9 Mounting position of power supplies...................................................................... 23 figure 2-10 ON / OFF position of external switch ................................................................... 23 figure 3-1 Position of rotary switches ...................................................................................... 24 table 3-2 List of all available alarms ........................................................................................ 26 figure 4-1 Clamps for external alarms...................................................................................... 29 figure 4-2 Modem kit ............................................................................................................... 31 figure 4-3 Position of external RF output................................................................................. 31 figure 4-4 Mounting position of batteries ................................................................................ 32 figure 5-1 System description .................................................................................................. 33 figure 5-2 Top view and clearance distance............................................................................. 34 figure 5-3 Wall mounting brackets........................................................................................... 35 figure 5-4 Grounding kit .......................................................................................................... 36 figure 5-5 Screw terminal......................................................................................................... 37 figure 5-6 Connector panel layout............................................................................................ 38 table 6-1 LED indication .......................................................................................................... 39 figure 6-2 Position of the DIP-Switch 1 and 2 and RAM/RTC battery ................................... 40 figure 6-3 Position of the rotary switches ................................................................................ 41 figure 6-4 Rotary switches and label........................................................................................ 41 table 6-5 DIP-switch configuration .......................................................................................... 42 table 6-6 List of AT commands................................................................................................ 44 figure 8-1 Position of power supply fuse ................................................................................. 48 figure 8-2 External filter at iDEN module................................................................................ 51 figure 8-3 Top view of a conversion module ........................................................................... 51 figure 8-4 Position of hex-coded rotary switches..................................................................... 52 table 8-5 Address of synthesizer .............................................................................................. 52 table 8-6 Adress of synthesizer, conversion modules .............................................................. 52 figure 8-7 Position of hex-coded rotary switches..................................................................... 52 figure 8-8 Position of control module ...................................................................................... 53 figure 8-9 Power supply ........................................................................................................... 54 figure 8-10 Position of special-nut M4 .................................................................................... 54 figure 8-11 Position of counter sunk screws on active combiner............................................. 55 figure 8-12 Position of feedforward amplifier reset board....................................................... 56 figure 8-13 Position of feedforward amplifiers........................................................................ 57 figure 9-1 Installation drawing of the Repeater........................................................................ 75 figure 9-2 Top view of the Repeater (left side, exemplary configuration)............................... 76 figure 9-3 Top view of the Repeater (right side, exemplary configuration) ............................ 77 figure 9-4 Cabling of one channel Repeater............................................................................. 78 figure 9-5 Block diagram of one channel Repeater.................................................................. 79 M0079A1A.doc Id.-No. 151775 Page 6 10-March-00 User’s manual for Repeater MRx01B Power LIST OF UNIT SPECIFIC ABBREVIATIONS ALC BCCH BITE BTS DL ETS Id.-No. I²C-Bus LMT MR OMC PABX PCMCIA PSTN Rev RF RLP RSSI RTC SDA SCL UL UPS VSWR Automatic Level Control Broadcast Control Channel Built In Test Equipment Base Transceiver Station Downlink European Telecommunication Standard Ident Number Inter Integrated Circuit Bus (Philips) Local Maintenance Timeout MIKOM Repeater Operation and Maintenance Centre Private Automatic Branch Exchange Personal Computer Modem Communication International Association Public Switched Telephone Network Revision Radio Frequency Radio Link Protocol Receive Signal Strength Indication Real Time Clock Serial Data Line of I²C-Bus Serial Clock Line of I²C-Bus Uplink Uninterruptable Power Supply Voltage Standing Wave Ratio CONTENTS OF DELIVERY Qty Repeater MRx01B Power Qty User’s manual for Repeater MRx01B Power Qty Software manual Qty Set of test protocols consisting of an electrical acceptance test protocol and a safety test protocol applying to the power supply Qty Spare parts kit Qty Wall mounting kit M0079A1A.doc Id.-No. 151775 Page 7 10-March-00 User’s manual for Repeater MRx01B Power HEALTH AND SAFETY WARNINGS F Note: F Note: F Note: F Note: F Note: M0079A1A.doc The electrical installation has to be performed in accordance with the safety regulations of the local authorities. Due to safety reasons the electrical installation must be performed by qualified personnel. The cover of this unit should not be opened while power is applied. Subsequent installation, commissioning and maintenance activities that require the unit to be powered with the cover open shall only be carried out by suitably qualified personnel. The grounding of the Unit has to be performed by all means. A grounding bolt is provided at the cabinet in order to connect the earth bonding cable. The Unit is heavy-weight. Make sure that a suitable mounting surface is used. Only adequate manpower is allowed to handle the system. ESD precautions have to be observed! Before maintenance work use the available grounding system to connect ESD protection measures. Due to power dissipation the Repeater may heat up the air volume inside the cabinet and reach a very high temperature. Therefore the Repeater must be mounted in the vertical plane to a wall or a mast without additional enclosure to provide sufficient ventilation. Between the housing and the wall a minimum distance must be kept in order to provide air circulation. Id.-No. 151775 Page 8 10-March-00 User’s manual for Repeater MRx01B Power PREAMBLE The MRx01B Power manual ( Ordering number Id.-No. 151775 ) includes the following parts: Chapter 1: Introduction Chapter 2: Functional description Chapter 3: Functions and features Chapter 4: Optional equipment Chapter 5: Installation Chapter 6: Setting to work Chapter 7: Trouble shooting Chapter 8: Maintenance Chapter 9: Appendices Chapter 10: Index Any intervention has to be performed by authorized persons only. If you need technical assistance with the Repeater MRx01B Power approach your local sales office or Mikom directly. MIKOM GmbH Industriering 10 86675 Buchdorf Germany Tel: +49 (0) 9099 6 90 Fax: +49 (0) 9099 69 31 email: sales@mikom.com http://www.mikom.com Under consideration of all references given in this manual, the Repeater should be taken into service without any complications and should operate trouble-free for a long time. M0079A1A.doc Id.-No. 151775 Page 9 10-March-00 User’s manual for Repeater MRx01B Power LIST OF INTERNATIONAL SALES OFFICES Allen Telecom Inc. Allen Telecom Pty Ltd Forem France 30500 Bruce Industrial Parkway 6 Stuart Street Cleveland, Ohio 44 139-3996 Padstow NSW 2211 USA Australia Z.I. des Ebisoires 78370 Plaisir France Phone: +1 ( 440 ) 349-8400 FAX: +1 ( 440 ) 349-8407 Phone: +61 ( 2 ) 9774-4200 FAX: +61 ( 2 ) 9774-4500 Phone: +33 ( 1 )30-79-15-30 FAX: +33 ( 1 ) 30-55-55-37 FOREM S.p.A. AT Singapore AT China Via Archimede N. 22/24 20041, Agrate Brianza Milan Italy 80 Marine Parade Road #19-1 Parkway Parade Singapore 449269 CITIC Building, # 11-04 19 Jianguomenwai Avenue Beijing China 100004 Phone: +39 ( 039 )605-41 FAX: +39 ( 039 ) 605-4477 Phone: +65 ( 345 ) 8022 FAX: +65 ( 345 ) 8033 Phone: +86 ( 10 ) 6508-3088 FAX: +86 ( 10 )6508-3066 AT Canada FOREM UK AT Hong Kong 1815 Ironstone Manor, # 12 Pickering, Ontario L1W 3W9 Canada Unit D Castle Industrial Park Pear Tree Lane Newbury, Berkshire U.K. RG 14 2EZ 1603 Remington Center, 23 Hung To road, Kwun Tong, Kowloon Hong Kong Phone: +1 ( 905 ) 839-3474 FAX: +1 ( 905 ) 839-4663 Phone: +44 ( 1635 ) 569-695 Phone: +852 ( 2389 ) 1844 FAX: +44 ( 1635 ) 569-463 FAX: +852 ( 2389 ) 4864 AT India MIKOM Switzerland MIKOM Austria B-256 Ground Floor. Chittaranjan Park New Delhi 110019 Tiergartenweg 1 4710 Balzthal Switzerland Himbergerstr. 7/3/1 2320Schwechat Austria Phone: +91 ( 11 ) 696-3918 FAX: +91 ( 11 ) 652-1648 Phone: +41 ( 6238 ) 61260 FAX: +41 ( 6238 ) 61261 Phone: +43 ( 1 ) 706 - 3999 FAX: +43 ( 1 ) 706 - 39999 table 1-1 List of international sales offices M0079A1A.doc Id.-No. 151775 Page 10 10-March-00 User’s manual for Repeater MRx01B Power 1 Introduction 1.1 Intended purpose Cellular telephone systems transmit signals in two directions between base stations and mobile telephones within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, a Repeater is used to extend transmission range. In the downlink path the Repeater picks up the signal from a donor antenna of an existing cell, amplifies and re-transmits it into the desired dark spot. In the uplink direction the Repeater receives signals from mobile stations present in its coverage area and re-transmits them to the corresponding base station. 1.2 About the MRx01B Power This repeater bi-directionally amplifies signals between multiple mobiles and a single base station in the frequency band. It is employed where poor topological conditions cause weak field strengths. It can provide highly selective amplification of band segments or channels in the frequency band. MRx01B Power modules can be combined with other repeater modules in order to create a multi-band repeater system. Modules operating in PCS1900, GSM1800, GSM900, or AMPS800 bands are available. When different modules are combined a common antenna and control interface are available. The MRx01B Power can be set-up locally or remotely. A PCMCIA slot for modem operation is an available option. The repeater has a large number of functions that can be monitored and changed by the operators via a terminal emulation program or the MIKOM OMC software platform. An easy to understand and simple to learn communication language is available to help the operator query status reports from the repeater or to change settings. 1.3 Modular design The MRx01B repeater’s modular design provides the flexibility in addressing present and future system needs. Each repeater is custom configured. The main unit includes equipment common to all systems ( cabinet, control module, power supply, mother board ). To this main unit hardware modules are added as needed. In addition to different duplexers, a wide range of conversion modules can be selected depending on the used network system. M0079A1A.doc Id.-No. 151775 Page 11 10-March-00 User’s manual for Repeater MRx01B Power 1.4 Applications The ability to customise the equipment in this way makes it possible to target the MRx01B to specific needs. For example, the following are some of the application options available with the MRx01B. • Channel selective or band selective • CDMA or TDMA • iDEN and analog networks • GSM900 or GSM1800 • PCS1900 M0079A1A.doc Id.-No. 151775 Page 12 10-March-00 User’s manual for Repeater MRx01B Power 2 Functional description The Repeater MRx01B Power can be equipped from one to four bands or channels depending on the used technology. The following block diagram shall illustrate the configuration of the system. *: one physical module contains UL and DL **: with more than two modules, the amplifiers are included; both are in one housing figure 2-1 Block diagram of MRx01B Power 2.1 General The Repeater consists of two amplifier chains, which are connected antiparallel. The receive path of one direction is connected to the transmit path of the other direction by a frequency separation unit, in the following denominated as a duplexer, which combines both signals to an antenna (see chapter 2.5). After the duplexer the signals get to a pre-amplifier and afterwards to a conversion module (see chapter 2.2). Then the signals are combined by the active combiner (see chapter 2.6) and afterwards amplified by the feedforward amplifier (see chapter 2.8), which provides the required output power. M0079A1A.doc Id.-No. 151775 Page 13 10-March-00 User’s manual for Repeater MRx01B Power In the feedforward amplifier a power detection measures the output power and controls the gain. This is called Automatic Level Control (ALC) and keeps intermodulations below an adjustable value. Finally, the signals are fed to the antenna. 2.2 Conversion modules The task of the conversion modules is to amplify the receive signals and to convert them into an intermediate frequency. The signals, then, proceed a filter stage comprising of highly selective filters, and run through a digital controllable attenuator. The attenuation can be set in steps of 2 dB, locally or remotely. By using the same synthesizer frequency, that was used to convert the signals down to intermediate frequency, the intermediate frequency is mixed up to the original frequency. The synthesizer is controlled via an I²C-Bus. In case of a breakdown in mains, gain or frequency data are nonvolatile stored in an EEPROM on board. The yellow label on the top shows the current ALC and CFO values related to the module. See figure 2-2 Top view of a conversion module for an exemplary channel or band module. figure 2-2 Top view of a conversion module 2.3 Mother board The function of the mother board is the communication between the conversion modules and the control module via the I²C-Bus. In the three and four channel configuration there is a mother board implemented on the lefthand side and on the right-hand side of the Repeater. In the one and two channel configuration of the Repeater there is only one mother board mounted on the right-hand side (see figure 9-2 and figure 9-3). Mother boards are located underneath the conversion modules. M0079A1A.doc Id.-No. 151775 Page 14 10-March-00 User’s manual for Repeater MRx01B Power figure 2-3 Top view of a mother board M0079A1A.doc Id.-No. 151775 Page 15 10-March-00 User’s manual for Repeater MRx01B Power 2.4 Control module SM 2009 ( Rev. 07 and higher ) The control module SM 2009 is a DOS compatible micro computer. The whole communication between the operator and the Repeater can be done via the control module. By using either the RS232 interface in connection with a modem card and a mobile the Repeater can be controlled remotely or locally by using a VT100 terminal, i.e. a PC emulating the VT100 terminal. Frequency and gain, power down of RF stages and ALC can be controlled and status messages can be received remotely. In case a modem or a mobile is connected, automatic alarm messages can be received by the operator. The data transfer between the control module SM 2009 and the mother board is realized by the I²C-Bus system. The I²C-Bus concept was developed by Philips for the serial connection of integrated circuits within one device. Two wires, SDA - serial data and SCL - serial clock, carry information between the devices connected to the bus. Each device is recognized by a unique address and can operate either as transmitter or receiver. The MRx01B Power I²C-Bus concept is working with a bit rate of 1.5 kbit/s. All MRx01B Power configuration parameters are stored in an EEPROM on the control module if a power supply failure occurs. M0079A1A.doc Id.-No. 151775 Page 16 10-March-00 User’s manual for Repeater MRx01B Power Functional description: • Second RS-232 port ( Not working yet, do not use it ) ( 01) • Configurable for MR or MOR (Master Unit) by DIP-Switches (02 ) • External alarms or PSTN modem selection by DIP-Switches ( = replacement of the external alarm cable) ( 03 ) • 8 additional TTL inputs ( opto-coupled ) ) ( 04 ) ( Not supported by software ) • 8 additional TTL outputs (O.C. or VCC by 1K-pull-up resistor) ( 05 ) ( Not supported by software ) • Connector for external temperature sensor ( 06 ) ( Not supported by software ) • Integrated Battery Backup Dummy Board incl. M1 Reset ( Id.-No. 143750 ). The switch is required to activate the battery backup. If a battery backup module is used, the switch must be set to ‘BBU’ position, otherwise there is no backup possible ( 07 ). • Soldering point for the PC/MODEM-switch in a Master Unit ( 08 ) • Reset jumper ( 09 ) • Fixed location for labels for control module ID (Mikom), repeater software (Mikom), board serial number, modem-driver licence ( 10 ) • RS232 interface for the connection of a PC or terminal ( local mode ) ( 11 ). M0079A1A.doc Id.-No. 151775 Page 17 10-March-00 User’s manual for Repeater MRx01B Power 09 06 LED L3 LEDs L1, L2 10 03 07 ON = No BBU OFF = BBU in use 01 11 02 05 05 Mode switch 08 +12 Vdc for the modem 04 I2Cbus Debug interf. figure 2-4 Configuration of the control module ( Rev.07 and higher ) M0079A1A.doc Id.-No. 151775 Page 18 10-March-00 User’s manual for Repeater MRx01B Power SW802 ON Ext. Alarm 1 Ext. Alarm 2 Ext. Alarm 3 Ext. Alarm 4 SW503 ON 8 MOR 7 MOR 6 MOR 5 MOR 4 MR 3 MR 2 MR 1 MR SW501 ON SW Download --Modem mode Manual mode OFF ----Local mode SW mode OFF PSTN (a) PSTN (b) PSTN (c) PSTN (d) OFF MR MR MR MR MOR MOR MOR MOR SW504 ON 8 VCC 7 VCC 6 VCC 5 VCC 4 VCC 3 VCC 2 VCC 1 VCC OFF O.C. O.C. O.C. O.C. O.C. O.C. O.C. O.C. DIP-Switches are at position OFF figure 2-5 Configuration of the DIP-Switches M0079A1A.doc Id.-No. 151775 Page 19 10-March-00 User’s manual for Repeater MRx01B Power 2.5 Duplexer The task of the duplexer is to isolate uplink from downlink, i.e. isolate transmit path from receive path. The pass bandwidth of the duplexer is the entire width of the uplink band and the downlink band. Duplexer with connector to mobile side 30 dB coupler 20 dB coupler 30 dB coupler Duplexer with connector to BTS side figure 2-6 Top view of the duplexers M0079A1A.doc Id.-No. 151775 Page 20 10-March-00 User’s manual for Repeater MRx01B Power 2.6 Active combiner After passing through the conversion modules, the signals will be combined by the active combiner module in the UL and in the DL path. The active combiner will be followed by the feedforward amplifier. figure 2-7 Top view of the active combiner module 2.7 Measuring aids With built-in RF probes test signals can be applied or detected. The probes provide a coupling factor of 30 dB respectivly 20 dB. Each duplexer (uplink and downlink) is equipped with one 30 dB coupler, the UL Input duplexer additionally with a 20 dB coupler for a modem or mobile (see chapter 4 Optional equipment). This facilitates measurements under all operational conditions, while an antenna or a dummy load may be connected. The position of the couplers on the duplexers is shown in figure 2-6 Top view of the duplexers. M0079A1A.doc Id.-No. 151775 Page 21 10-March-00 User’s manual for Repeater MRx01B Power 2.8 Feedforward amplifier The feedforward amplifier is the final stage which enables high output power as well as a high ICP3. One amplifier has to be installed for the uplink and one for the downlink. figure 2-8 Top view of the feedforward amplifier 2.9 Power supply For the MRx01B Power power four power supplies are necessary. Power supplies are available with different mains power. See list below for available power supplies. • 115 VAC ± 15% / 40 - 65 Hz • 230 VAC ± 15% / 40 - 65 Hz • 185 - 320 VAC / 40 - 65 Hz • 24 VDC • 42 to 60 VDC • 80 to 130 VDC M0079A1A.doc Id.-No. 151775 Page 22 10-March-00 User’s manual for Repeater MRx01B Power The following figure shows the mounting position of the power supplies in the MRx01B Power cabinet. figure 2-9 Mounting position of power supplies Power supplies can be equipped with a power socket, protected with two fuses. Each power supply can be switched on or off by means of an external switch. The modules of the Repeater are voltage free if all power supplies are switched off. The power socket, however, is still provided with mains power. F Note: The service connecter must not be used for anything else but service devices with low power consumption, e.g. a Laptop. See figure 2-10 ON / OFF position of external switch. figure 2-10 ON / OFF position of external switch F Note: To switch the whole Repeater voltage free, you have to remove the fuses F1 and F2 on the screw terminal. The power supply is factory-set and should not be changed. M0079A1A.doc Id.-No. 151775 Page 23 10-March-00 User’s manual for Repeater MRx01B Power STYLEREFSEQARABICFunctions and features 3.1 Band and channel selectivity The selectivity is achieved by highly selective filters in the IF part of the band / channel modules. 3.2 Gain setting The gain can be changed by introducing attenuation into the amplifier chain. By using a rotary switch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum in steps of 2 dB. The attenuation can be set for the UL and DL path separately. The rotary switches are mounted on the mother board. These switches are accessible through the long hole between the two conversion modules (see figure 3-1 Position of rotary switches). They can be adjusted easily by means of a small screwdriver. long hole figure 3-1 Position of rotary switches For remote control an RS232 interface can be used to set the gain. The functions of the control module may be used locally by means of a VT100 terminal or a personal computer emulating the VT100 terminal. See also chapter 6.2, which deals with settings of operational parameters. M0079A1A.doc Id.-No. 151775 Page 24 10-March-00 User’s manual for Repeater MRx01B Power 3.3 ALC In order to protect the amplifiers from overload and to prevent the system to generate spurious emission, the amplifiers have an Automatic Level Control, designed to limit the output power to a defined level. A part of the output power is rectified, amplified and used to control an attenuator network. FNote: 3.4 The ALC protects the feedforward amplifier. To keep spurious emissions below certain limits, the input power into the Repeater and the attenuation settings of the repeater have to be considered properly. CFO Each conversion module has got a different offset of the set center frequency. This offset is compensated by software settings (see software manuals).These settings are already factory set and should only be changed when neccessary. The CFO (center frequency offset) is noted on the label on top of the conversion module. 3.5 BITE and alarms The Built-In TEst concept comprises the monitoring of the power supplies, the operational currents in the conversion modules, the mother board and the remote control interface. Furthermore, the synthesizer lock and the temperature of the Repeater are monitored. There are three multicoloured LEDs mounted on the control module. The LED L3 indicates the presence of electrical power of +12VDC in the Repeater. Every alarm is indicated by the failure LEDs, L1 and L2. For the position of the LEDs on the control module see figure 2-4 Configuration of the control module ( Rev.07 and higher ). All alarms can be checked by typing the ‘STATUS HIST’ command. Minor alarms with no influence on the system can be cancelled by typing the ‘ALARMACKN’ command, e.g. ALC active, VSWR or door open. The following print screen illustrates a possible ‘STATUS HIST’ report In case a hardware failure is detected the concerning hardware module has to be replaced. An alarm can be acknowledged manually by software command. If all alarms have been acknowledged the summary error LEDs are set back to green indication. In case of mains power failure all data of the STATUS HIST list are lost. The alarm can also be sent to the OMC. M0079A1A.doc Id.-No. 151775 Page 25 10-March-00 User’s manual for Repeater MRx01B Power If monitored via a modem automatic dialling will generate a summary alarm message. The operator can acknowledge the alarm message by a simple ring back and after that he is able to request a detailed status report. The following list comprises all available alarms in the Repeater. These alarms may occur in the STATUS HIST list. NO. (7) 10 11 12 (13*) (14*) (15*) (16*) (17**) ** (...) ALARM NAME AMPLIFIER BIAS POWER SUPPLY 8 V POWER SUPPLY 12 V MAINS SYNTH DOOR VSWR ALC LITHIUM BATTERY VOLTAGE OVERTEMP INVALID LOGIN ATTEMPT I2C BUS EXT. ALARM 1 EXT. ALARM 2 EXT. ALARM 3 EXT. ALARM 4 EXT. BATTERY ALARM ACTIVE STATUS FAILURE FAILURE FAILURE FAILURE FAILURE OPEN ALARM FAILURE LOW FAILURE FAILURE FAILURE FAILURE FAILURE OVERTEMP. Alarm default settings changeable by software instruction SET ALIAS. This alarm may be activated together with the external alarms, for instance UPS or temperature Optional alarms table 3-2 List of all available alarms M0079A1A.doc Id.-No. 151775 Page 26 10-March-00 User’s manual for Repeater MRx01B Power 3.5.1 Handling of alarms As soon as the software recognises a valid alarm, a message is transmitted to the OMC. If the repeater is operating in modem mode the alarm message ‘MIKOM> REPEATER REQUIRES OPERATOR ATTENTION’ will be sent via modem to the terminal or the OMC. The first of two stored telephone numbers will be dialled. In case a connection cannot be established the second telephone number will be dialled. If this should be unsuccessful as well, the call will be repeated after a pre-set delay. Default setting is 10 minutes. The repetition cycle can be set by software. The alarm check routine is searching every 10 seconds for alarms ( polling principal ). To decide whether an alarm is a valid alarm it must remain for 5 polling cycles, only then it will be recognized and entered in the alarm history. As soon as the alarm is valid the contacts of the alarm relay at the mother board are set. Additionally two summary error LEDs are set to red light to indicate an alarm. These LEDs are mounted on the control module (see figure2-4). The entry in the alarm history describes the alarm type, the time and the date when it occurred. It is not possible to locate the defect module, only the reason. Entered alarms in the alarm list can be acknowledged by simply ringing back and typing a software command. It is also possible to acknowledge alarms in local mode. Acknowledged alarms will be indicated with ‘-ACK’. As soon as the alarms have been acknowledged the alarm relay will be reset and the summary LEDs switch back to green light again. To switch off external alarm indication devices can only be done by acknowledging the alarms. If the same alarm cause occurs again, it will be entered in the alarm list ( not acknowledged ) after 5 polling cycles. An already acknowledged alarm must have an interruption of at least 5 polling cycles to be detected by the software as a new alarm. Only then the alarm will be entered again in the alarm history ( not acknowledged ). All data of the alarm history are lost, if the repeater will be booted by software or if the repeater was disconnected from mains. There exists no command to delete the alarm history, to boot the repeater is the only way to clear the alarm history. The alarm list has a capacity of about 50 alarm entries. If more alarms occur the oldest message will be deleted first ( FIFO principal ). In the software exists no alarm clear message, i.e., the repeater sends no message to the terminal or the OMC if an alarm has disappeared by itself. M0079A1A.doc Id.-No. 151775 Page 27 10-March-00 User’s manual for Repeater MRx01B Power 3.5.2 Status report Two instructions enable the operator to gain knowledge of the system status. Typing the GET command will be responded by a listing of all settings of the Repeater. STATUS will be responded by a listing of all individual status information. The complete listing of the dialogue language with the processor of the control module including the instructions to and the messages from the system is available as a separate manual. 3.5.3 Severity levels This parameter defines five severity levels for an alarm and can be set in the alarm mask (detailed description in the software manual). The severity levels indicate how the capability of the managed object has been affected. The levels are described below and are ordered from most severe to least severe: - Critical: The critical severity level indicates that a service affecting condition has occurred and an immediate corrective action is required to restore the capability of the managed object. - Major: The major severity level indicates that a service affecting condition has developed and an urgent corrective action is required. Such a severity can be reported, for example, when there is a severe degradation in the capability of the managed object and its full capability must be restored. - Minor: The minor severity level indicates the existence of a non-service affecting fault condition and that corrective actions should be taken in order to prevent a more serious failure. Such a severity can be reported, for example, when the detected alarm condition is not currently degrading the capability of the managed object. - Warning: The warning severity level indicates the detection of a potential or impending service affecting failure before any significant effect has been caused. Action should be taken to further diagnose and correction of the problem shall prevent a more serious service affecting failure. - Disable: The disable severity level indicates that the detected failure has no influence on the system and shall not be sent to the terminal. M0079A1A.doc Id.-No. 151775 Page 28 10-March-00 User’s manual for Repeater MRx01B Power 4 Optional equipment The following modules can be integrated as an option. 4.1 VSWR module VSWR signal is continually measured by a special VSWR module. An alarm can be given for VSWR < 10 dB. 4.2 External alarms With the following option it is possible to monitor 4 external alarms via the Repeater software. Hence the status of the connected device, e.g. UPS, can be monitored. The contacts of the alarms can be accessed at clamps on the main board (right-hand side of the Repeater). The electrical connection has to be as follows: External alarm 4 (high active) External alarm 3 (high active) External alarm 2 (low acitve) External alarm 1 (low acitve) Ground figure 4-1 Clamps for external alarms Configuration: 5 V / 0.5 mA max. for open collector applications. All external alarms are normally high without connection. Due to the fact that the external alarms 3 and 4 are high active, they have to be connected to ground to prevent an alarm message. M0079A1A.doc Id.-No. 151775 Page 29 10-March-00 User’s manual for Repeater MRx01B Power The factory-set response after typing the software command STATUS EXTALARM is for instance „EXT. ALARM 1 OK“, if the alarm is not active and „EXT. ALARM 1 FAILURE“, if the alarm is active. The name for each external alarm and the name for the alarm message can be defined by the customer with the corresponding software command. The following example describes the response for the external alarms to control an UPS. Example: External alarms if the UPS is active EXTERNAL ALARM STATUS UPS alarm active Battery low ! UPS door open Battery door open or External alarms if the UPS is not active EXTERNAL ALARM STATUS UPS not active Battery OK UPS door closed Battery door closed If the optional external alarms are part of the delivery, they will be switched on by a software release, i.e. they are distributed via the software. 4.3 Modem The Repeater can be equipped with a modem for the remote control of the repeater. This allows the operator to change settings and querry information of the Repeater remotely. See figure 4-2 for the optional modem kit. This kit is available with and without modem. For information referring to the optional modem see chapter 4.4 and chapter 6.2.4. M0079A1A.doc Id.-No. 151775 Page 30 10-March-00 User’s manual for Repeater MRx01B Power PCMCIA card Modem figure 4-2 Modem kit 4.4 External RF output An external output is available at the outside of the housing as an option. This enables e.g. the connection of an integrated modem or mobile to an additional external antenna or it might be used for UL diversity. The connector type is N female. External RF figure 4-3 Position of external RF output M0079A1A.doc Id.-No. 151775 Page 31 10-March-00 User’s manual for Repeater MRx01B Power 4.5 Battery backup module If backup is required only for the control module and the modem, low capacity batteries are available to operate controller and modem for at least ten minutes under normal environmental conditions. Battery backup is provided for the control module to transmit alarm information in case of power failure. The battery type is a NiCd 8.4V/300 mAh. The battery backup is sufficient enough to support multiple dial out attempts via modem in case of ‘system engaged’ or other communication problems for at least ten minutes under normal environmental conditions. F Note: This battery backup module is provided for the control module only. The batteries are protected from deep discharge by use of a low voltage disconnect circuit. A local switch is provided to disconnect the battery backup system during maintenance to ensure that all circuits are voltage-free. The switch is located on the battery backup module. Switch ON (default) OFF Battery backup active Battery backup not active The module is directly plugged into the control module. During the charging process a green LED V7 on the module indicates, that the battery is charged at the moment. After finishing the process the LED V7 will be switched off. The batteries are mounted underneath the modem mounting plate (see following figure). Batteries figure 4-4 Mounting position of batteries M0079A1A.doc Id.-No. 151775 Page 32 10-March-00 User’s manual for Repeater MRx01B Power Installation TX Downlink RX Uplink TX Uplink RX Downlink to/from Mobile Stations to/from BTS Repeater System TX Downlink RX Uplink TX Uplink RX Downlink Mobile BTS figure 5-1 System description M0079A1A.doc Id.-No. 151775 Page 33 10-March-00 User’s manual for Repeater MRx01B Power 5.1 Mechanical installation Note: Due to power dissipation the Repeater may heat up the air volume inside the cabinet and reach a very high temperature. Therefore it is necessary to mount the Repeater in the vertical plane to a wall or a mast without additional enclosure to provide sufficient ventilation. Between the housing and the wall a minimum distance must be kept in order to provide air circulation. The Repeater must be mounted in the vertical plane to a wall or a mast, which means the connectors have to be located at the bottom. Use the mounting brackets, which are part of the delivery. This will guarantee a minimum distance between the wall and the Repeater housing. The cabinet must be fixed to the wall (brackets) with four screws. Check the correspondence of the wall mounting kit and the wall. figure 5-2 Top view and clearance distance F Note: M0079A1A.doc The weight of the MRx01B Power is approximately 47 kg in standard configuration. Id.-No. 151775 Page 34 10-March-00 User’s manual for Repeater MRx01B Power Mounting procedure: Dismount the mounting brackets first. They are screwed tight to the housing with four socket head cap screws M8.0x16 (see figure below) and two tire bolts. mounting brackets figure 5-3 Wall mounting brackets Use the wall mounting sheet to mark the position of the drilling holes. Drill 4 holes and screw the mounting brackets to the wall. Attach the upper two socket head cap screws M8.0x16 to the Repeater housing. Now it is possible to hang the Repeater into the mounting brackets. Fix then the lower two socket head cap screws M8.0x16 and the 2 tire bolts. F Note: The unit is heavy-weight. Make sure that a suitable mounting surface is used. Only adequate manpower is allowed to handle the system. The installation position of the Repeater follows from the installation drawing (see figure 9-1 Installation drawing of the Repeater). Make sure that there is free access to the electrical connections. The allowed bending radius of the connected cables must not be exceeded. Furthermore the Repeater shall be mounted in a way that there is free access to the individual units inside the cabinet, while the door of the Repeater is open. Therefore keep a clearance distance of 1 m on each side, on top and below the unit. See figure 5-2 Top view and clearance distance. M0079A1A.doc Id.-No. 151775 Page 35 10-March-00 User’s manual for Repeater MRx01B Power 5.2 Electrical installation FNote: 5.2.1 ESD precautions have to be observed! Before working inside the cabinet use the available grounding system to connect ESD protection measures. The electrical installation has to be performed in accordance with the safety regulations of the local authorities. Due to safety reasons the electrical installation must be performed by qualified personnel. The cover of this unit should not be opened while power is applied. Subsequent installation, commissioning and maintenance activities that require the unit to be powered with the cover open shall only be carried out by suitably qualified personnel Grounding Grounding has to be performed by all means. Therefore a grounding bolt is provided at the cabinet. An earth bonding cable will be mounted in the factory and will be delivered with the unit. Don’t use the grounding screw for connecting external devices. The complete grounding kit is part of the delivery schedule, see figure 5-4 Grounding kit. figure 5-4 Grounding kit M0079A1A.doc Id.-No. 151775 Page 36 10-March-00 User’s manual for Repeater MRx01B Power 5.2.2 Power connection A firmly installed mains cable 3 x 1.5 mm² is used, which is fed into the housing through a watertight cable gland. Due to safety reasons the power supply lead has to be protected by two 8 A fuses. Inside the Repeater, mains are connected to a screw terminal. See figure 5-5 Screw terminal for the position of the two 8 A fuses. Before connecting electrical power to the Repeater grounding has to be performed. The Repeater is equipped with a firmly connected power cord 3 x 1.5 mm². Due to safety reasons the power supply lead of the Repeater has to be protected with two 8 A fuses, type MT. In the event the length of the power cord should not be sufficient it can be replaced by a longer cable. Fuses F1 and F2 figure 5-5 Screw terminal F Note: 5.2.3 If the power supply lead has to be replaced use a cable of the same quality. Connection of the antenna cables The Repeater has two female antenna connectors 7/16 (optionally N). For mounting the corresponding cable connectors we recommend to refer to the applicable documentation of the respective connector manufacturer. The bending radius of the antenna cables must remain within its specification. This will warrant proper operation of the system; otherwise changes in the electrical behaviour of the cable might occur which could cause malfunction of the Repeater system. M0079A1A.doc Id.-No. 151775 Page 37 10-March-00 User’s manual for Repeater MRx01B Power F Note: It is sufficient to fix the 7/16 antenna connectors hand-screwed. Any use of a tool (like tongs) might cause damage to the connectors and thus lead to malfunctioning of the Repeater. There are two 7/16 female antenna connectors at the outside of the housing accessible on the connector panel (see following figure). figure 5-6 Connector panel layout The 7/16 TX-downlink connector should be connected to the antenna system for the communication with the mobile units. Mobile The 7/16 TX-uplink connector should be connected to the antenna system for the communication with the Base Transceiver Station. BTS As an option a 7/16 - N adapter is available. M0079A1A.doc Id.-No. 151775 Page 38 10-March-00 User’s manual for Repeater MRx01B Power 6 Setting to work 6.1 Preparation F Note: It is not allowed to operate the Repeater without termination of the antenna connections! The termination can be performed by the antenna connection as well as a dummy load or the 50-Ohm-terminated connection of a measuring instrument. Before bringing the Repeater system into service it is necessary to measure the antenna isolation. The Repeater system has its maximum available gain when the attenuation is set to zero. On site the maximum allowed gain is 15 dB less than the value of the antenna isolation. In order to check the function of the Repeater system on site it is advisable to operate the Repeater system with 50 Ohm termination. This makes it possible to set the necessary gain and to test the set value without the necessity of transmitting on air. In order to perform settings the Repeater has to be opened. Please, ensure not to damage the seals, which are on the modules situated on the conversion modules inside of the Repeater, because this would lead to risk the success of warranty claims. After taking the Repeater into service following signals occur during the boot process. Internal LED L1 green red Flashes red short time Internal LED L2 green red Internal LED L3 green Flashes red short time Cause Power on state, Software boot starts Software boot starts Software is running table 6-1 LED indication 6.2 Setting of operational parameters Attenuation of the Repeater can be set manually by means of rotary switches, frequency can be set locally or remotely. There are three different possibilities to set the operational parameters: -manual settings by means of rotary switches -local control via RS232 interface and PC -remote control via modem M0079A1A.doc Id.-No. 151775 Page 39 10-March-00 User’s manual for Repeater MRx01B Power 6.2.1 Manual settings by means of rotary switches The manual mode allows the user to set the required channels and attenuation by means of rotary switches. With a small screwdriver, which fits through the long holes of the conversion modules, the values can be adjusted by turning the switch carefully to the desired position. F Note: To enable manual settings of parameters the mode switch (DIP-Switch 1) has to be changed from OFF to ON. The DIP-Switch is mounted on the control module, located on the left side of the Repeater. RAM/RTC Battery DIP-Switch 1 and 2 RS 232 port connector figure 6-2 Position of the DIP-Switch 1 and 2 and RAM/RTC battery 6.2.2 Setting of the attenuation The gain can be set by introducing attenuation into the amplifier chain. By using a rotary switch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum in steps of 2 dB. The attenuation can be set for the UL and DL path separately. The rotary switches are mounted on the mother board. These switches are accessible through the long hole between the two conversion modules (see figure 6-3 Position of the rotary switches). They can be adjusted easily by means of a small screwdriver. M0079A1A.doc Id.-No. 151775 Page 40 10-March-00 User’s manual for Repeater MRx01B Power long hole figure 6-3 Position of the rotary switches A label on the conversion module, located next to the rotary switch, illustrates the usage of the rotary switch. figure 6-4 Rotary switches and label F Note: M0079A1A.doc Gain can be changed independently for the uplink and downlink path. Id.-No. 151775 Page 41 10-March-00 User’s manual for Repeater MRx01B Power DIP-Switch configuration: DIP-Switch ON manual remote mode n.c. software download manually controlled OFF (default values) auto local mode n.c. software download controlled by software table 6-5 DIP-switch configuration 6.2.3 Settings via personal computer as terminal Instead of manually setting operational parameters via rotary switches it is also possible to use the functions of the control module. The local mode for settings via PC has to be set. Therefore the DIP-Switch 2 has to be at position OFF. DIP-Switch 2 See figure 6-2 for postition of DIP switch 2 A VT100 terminal or a PC with VT100 emulation can be connected to the control module SM2009 by a standard RS232 cable, if necessary in connection with an adapter 9 to 25. See figure 6-2 for position of the RS 232 connector. Cable Connections PC 9 contact SUB - D- Connector male PC PIN M0079A1A.doc Control Module SM2009 9 contact SUB - D- Connector male RS 232 MRx01B Power PIN Id.-No. 151775 Page 42 10-March-00 User’s manual for Repeater MRx01B Power The following communication mode between control module and VT100 is set initially. 9600 baud - 8 bit - no parity -1 stopbit These settings can only be changed after connection of the terminal. If all wanted settings have been initialized and a modem has to be used it will be recommended to check whether the settings comply with the capabilities of the modem and the line. Modifications are possible by software commands. F Note: Settings on the Repeater can be performed after the following procedure only. After connecting the PC to the Repeater, following procedure is necessary to get access to the program. MIKOM REPEATER MRx01B Power - SM2009 - SW: REP1007V1.11 ENTER <.>TO LOGIN 1. Step: Type the two keys ( . ) FULLSTOP and (↵) ENTER You have to type the keys: 2. Step: ENTER PASSWORD You have to enter: M0079A1A.doc UserID1 ↵ The input is case sensitive, no blanks. After three mistrial follows disconnection. 3. Step: F Note: ↵ ENTER USER ID You have to enter: F Note: P-word1 ↵ The input is case sensitive, no blanks. After three mistrials follows disconnection. Id.-No. 151775 Page 43 10-March-00 User’s manual for Repeater MRx01B Power 6.2.4 Settings via modem The Repeater can be equipped with a modem. If so, the repeater will be delivered with a preset init string. This init string was used for internal tests. In case no connection can be established check the local conditions and change the init string if necessary. The following list contains the description of the AT commands: &F Sets modem to factory configuration E0 Echo OFF S0=1 Auto answer ON; the GSM module / M1 modem goes offhook after the first ringing signal. S7=60 Waiting time for connection after dialing; permissible values are from 0 ... 60. B13 Setting to 9600 bps asynchronous mode \ N6 Auto reliable operation \ N0 Standard operation, no error correction +CBST=7,0,1 Set bearer service type to 9600 bps. Non-transparent connection (uses RLP) X3 Not waiting for dial tone; usually used at PABX. *P1 Switch ON phone &K4 Enables XON / XOFF flow control table 6-6 List of AT commands M0079A1A.doc Id.-No. 151775 Page 44 10-March-00 User’s manual for Repeater MRx01B Power 7 Trouble shooting All Repeaters are factory-set to „Power down disabled“ status, this means the channel group is active. To switch off the channel group use the software command „PWRDOWN enabled“. (You’ll find a detailed description in the software manual.) 7.1 Error indication l = LED on - = LED off Internal LED L1 green red Internal LED L2 green red 7.2 Internal LED L3 green Cause No power. Check presence of power at the input; replace fuse according to chapter 8.3, check battery backup module Indicates a summary failure Alarm monitoring with the STATUS HIST command Check alarms with ‘status hist‘ command. 1. If a hardware module is damaged, replace corresponding hardware module. 2. Minor alarms with no influence on the system can be cancelled by confirming the alarm with the ‘alarmackn’ command, e.g., ALC active, VSWR, RSSI or DOOR OPEN. 3. If all alarms have been acknowledged the summary error LEDs will be set back to green indication. 4. In case of mains power failure the contents of the actual STATUS HIST list is lost. For a complete list of available alarms, see table 3-2 List of all available alarms M0079A1A.doc Id.-No. 151775 Page 45 10-March-00 User’s manual for Repeater MRx01B Power 7.3 Power supply The output voltage is factory set and should not be changed. 7.4 General remarks • After a software download previous user settings (data default values) might be overwritten. Before you start a software download save the set values for: centre frequency attenuation ALC threshold CFO • If an ALC or AMPBIAS alarm occurs during installation or commissioning an user error might be the cause, due to wrong measurements. M0079A1A.doc Id.-No. 151775 Page 46 10-March-00 User’s manual for Repeater MRx01B Power 8 Maintenance 8.1 General F Note: The Repeater does not require preventative maintenance measures. It is only recommended to replace the RAM/RTC battery after three years usage as a prophylactic measure. The nominal lifetime of these batteries is five years under normal environmental conditions. In the event of a malfunction it is advantageous to check the status of the antenna systems as well as the continuity of the entire cabling including connectors, before replacing the modules. Maintenance on the Repeater shall be performed only by replacing modules. Soldering on printed circuit boards shall be avoided. In order to sustain warranty take care not to damage unintentionally the seals on the modules. The spare part list, consequently, contains only units, which can be replaced without tuning or complex soldering work. F Note: Defect parts should be replaced by original parts from MIKOM only. All interventions inside the housing are at one’s own risk. During maintenance ensure that the Repeater has been disconnected from mains. Open the lock at the connector panel and remove the cover plate. To open the housing use a Torx key and unscrew the four Torx screws. 8.2 Replacement of the fuses (mains) The mains cable is protected with two fuses F1 and F2 8A type MT. They are accessible inside of the Repeater at the fuse terminal on the right side. Open the screw plug for the fuse and take out the fuse. F Note: Use only fuses of the same type and the same rating when replacing! See figure 5-5 Screw terminal for position of the 8A fuses. M0079A1A.doc Id.-No. 151775 Page 47 10-March-00 User’s manual for Repeater MRx01B Power 8.3 Replacement of the power supply fuse Each power supply is protected with a fuse 10 A / 35 V. The fuse is mounted outside of the power supply housing. (see following figure) F Note: Use only fuses of the same type and the same rating when replacing! figure 8-1 Position of power supply fuse 8.4 Replacement of the mains cable The Repeater will be delivered with a firmly connected mains cable. In case the length of the delivered mains cable should not be sufficient or in case of a defect, the mains cable can be replaced. F Note: Disconnect Repeater from mains first. Remove the clamping profile at the outside of the housing by pulling at the mains cable. Open the PG9 threaded joint with a spanner size 17. Inside the housing remove the plastic cable clip by unscrewing the tallow-drop screw. Then use a small screwdriver and open the screws of the fuse terminal. M0079A1A.doc Id.-No. 151775 Page 48 10-March-00 User’s manual for Repeater MRx01B Power Now the mains cable can be removed by pulling at the cable. For the installation of a new cable strip the isolation of a new cable to the length of 18 cm. Put the screw of the cable gland over the cable then use the joint rubber and pull it over the cable. This will guarantee a tight connection. Now insert the cable. Inside the housing pull an insulated tube with the length of 8 cm over the wires. Now close the PG9 threaded joint. Screw the wires to the fuse terminal. Fix the cable with the plastic cable clip. Put the cable in the guide shaft and close it with the clamping profile. 8.5 Replacement of the RAM / RTC battery The RAM / RTC battery of the control module has to be replaced in case of memory loss or as a preventive measure after approximately three years usage. The RAM / RTC battery is mounted on the left-hand side of the Repeater on the control module. REFIf the optional battery backup module and the optional mobile kit are installed, the battery backup board and the modem-reset board, which are plugged into the control module have to be removed first. Take off the Lithium battery by means of a small screwdriver, placed between the battery and the battery socket. The type of the battery is CR 2450 Lithium 3 V / 500mAh, manufacturer is RENATA. After replacement of the RAM battery, the control module has its basic settings, date and time have to be set to the actual value. For position of the RAM/RTC battery see figure 6-2 EMBED F Note: Before replacing the battery, disconnect the Repeater from mains. Observe the rules for changing Lithium batteries. Wrong connection or treatment may result in bursting of the battery and dissemination of hazardous substances. Don’t try to charge this battery M0079A1A.doc Id.-No. 151775 Page 49 10-March-00 User’s manual for Repeater MRx01B Power 8.6 Replacement of the duplexers This description is valid for the one channel configuration of the Repeater only. For different configurations refer to the assembly guide for the Repeater. Remove the semi-rigid cables which connect the UL output and the DL output with the feedforward amplifier by loosing the SMA connectors. Use a torque wrench. Then remove the semi-rigid cables from the conversion modules. (BTS side marked with a red spot). It is recommended not to remove the amplifier which is mounted on the backside of the duplexer. A new duplexer will be delivered with a premounted amplifier. Unscrew the four counter sunk screws M3 at the connector panel of the Repeater. See figure 5-6 Connector panel layout. For mounting the duplexers proceed in reverse order. The cables have to be connected like shown in figure 9-4 Cabling of one channel Repeater. 8.7 Replacement of conversion modules To remove the conversion modules, disconnect the SMA connectors by means of a torque wrench. If the Repeater is equipped with iDEN channel modules, the external filter on top of the modules must be dismounted beforehands. The external filter box covers two of the socket head cap screws the iDEN module is fixed with. M0079A1A.doc Id.-No. 151775 Page 50 10-March-00 User’s manual for Repeater MRx01B Power Unscrew the socket head cap screw on top of the external filter box, remove the box carefully and continue the dismounting procedure like described below. Socket head cap screw figure 8-2 External filter at iDEN module Unscrew six socket head cap screws by means of a hex socket key. Pull carefully by means of the mounting strap, fixed on the module and take off the modules. Socket head cap screws Mounting strap * Connecting the conversion modules depends on the number of channels your Repeater is equipped with, i.e. with one up to four (iDEN: six) channels. Each configuration has got a different cabling. See assembly guide of the channel modification kits for the cabling and functional description of the conversion modules dependent on the configuration of the Repeater figure 8-3 Top view of a conversion module *: iDEN modules are equipped with mounting straps on the left and on the right side. M0079A1A.doc Id.-No. 151775 Page 51 10-March-00 User’s manual for Repeater MRx01B Power For the exchange of a conversion module or the installation of a new conversion module, the slave address of the synthesizer has to be set. This can be done by means of hex-coded rotary switches mounted on the lower side of the modules Hex-coded rotary switch for UL Hex-coded rotary switch for DL The synthesizer address must be set like shown in the following table: Address UL DL Conversion module Channel one Channel two Channel three Channel four figure 8-4 Position of hex-coded rotary switches table 8-5 Address of synthesizer Conversion modules with variable bandwidth have four rotary switches. The synthesizer address must be set like shown in the following table: Filter 1 UL DL Channl one Channel two Channel three Channel four Filter 2 UL DL table 8-6 Adress of synthesizer, conversion modules with variable bandwidth figure 8-7 Position of hex-coded rotary switches at variable bandwidth module Further instructions for band selective modules with variable bandwith can be found in a separate document. M0079A1A.doc Id.-No. 151775 Page 52 10-March-00 User’s manual for Repeater MRx01B Power 8.8 Replacement of the control module SM 2009 The control module is a Printed Circuit Board situated on the left-hand side of the Repeater. Disconnect the DC cable from power supply. Disconnect the flat cable. Remove the Tyrap which is fixed to the control module. Disconnect the RS232 cable from the modem if the Repeater is equipped with a modem. Dismount the battery backup board, if the battery backup module is installed. Take off the whole control module completely with mounting plate by unscrewing four tallow drop screws M4. For mounting proceed in reverse order. Position of the control module in the Repeater is illustrated in REFthe following figure. Control module figure 8-8 Position of control module M0079A1A.doc Id.-No. 151775 Page 53 10-March-00 User’s manual for Repeater MRx01B Power 8.9 Replacement of power supplies FNote: Ensure that mains are disconnected. Open the Repeater to get access to the devices. Remove all connected cables from the clamps of the power supply. Try to loose the plug by means of a small screwdriver placed between the plug and socket. ON Fuse 10A / 35V figure 8-9 Power supply The power supply is fixed to the Repeater housing by means of two special nuts M4. After loosen the screws the power supply can be removed. To open these screws a special key with a spherical head is required. Place a small screwdriver between the Repeater housing and the power supply to loose the device. figure 8-10 Position of special-nut M4 F Note: M0079A1A.doc Don’t forget to put heat conducting paste on the mounting side for installation of a new power supply. Use the conducting paste, which is included in the spare parts kit. Id.-No. 151775 Page 54 10-March-00 User’s manual for Repeater MRx01B Power 8.10 Replacement of active combiner modules The active combiner modules are mounted on both sides of the Repeater. Disconnect all SMA connectors by means of a torque wrench. Unscrew two counter sunk screws M3x20mm. counter sunk screws figure 8-11 Position of counter sunk screws on active combiner The cabling of the active combiners depends on the configuration of the Repeater. For correct connections see assembly guide for the channel modification kits. 8.11 Replacement of feedforward amplifier There is one feedforward amplifier mounted on each side of the Repeater. A special reset board is connected to the 15 pole SUB-D connector. (See figure 8-12 Position of feedforward amplifier reset board) This reset board is part of the feedforward amplifier. A new feedforward amplifier will be delivered with a premounted reset board. M0079A1A.doc Id.-No. 151775 Page 55 10-March-00 User’s manual for Repeater MRx01B Power Reset board figure 8-12 Position of feedforward amplifier reset board Remove the ready made cable which is plugged to the 15 pole SUB-D connector of the reset board. Unscrew the screw clip first. Unscrew the 6 socket head cap screws. The SMA connectors can be removed only after dismounting the amplifier. The position of the feedforward amplifiers is illustrated in figure 8-13 Position of feedforward amplifiers. M0079A1A.doc Id.-No. 151775 Page 56 10-March-00 User’s manual for Repeater MRx01B Power figure 8-13 Position of feedforward amplifiers M0079A1A.doc Id.-No. 151775 Page 57 10-March-00 User’s manual for Repeater MRx01B Power 9 Appendices 9.1 Repeater specifications ELECTRICAL SPECIFICATIONS Id-No: Frequency range & bandwidth Frequency selectivity; Gain outside operating band Gain (nominal) Gain adjust Gain variation over frequ. and temp. Tolerance per step Delay Delayripple Output power ALC limit (test case) at 2 equal carriers ICP3 ALC limit tolerance of frequency and temperature ALC overload reaction time delay Noise figure Test coupler Return loss (@ 25° C amb. temp.) Power Supply Power consumption (1 module) Remote control interface Connectors Environmental and Safety Built in test equipment Alarm forwarding Control functions MR301B Power 150047 Up to 25 MHz in GSM900 ± 400 kHz: 50 dB max.; ± 600 kHz: 40 dB max. ± 1000 kHz: 35 dB max.; ± 5000 kHz: 25 dB max. 85 dB 0 to 30 dB in steps of 2 dB ± 2.5 dB (± 3.5 dB at extreme temperature range)* ± 0.5 dB from 0 to 6 dB attenuation ± 2.0 dB from 8 to 30 dB attenuation 6 µsec.max. 150 ns 30 dBm (@ 25° C) +27 dBm / +27 dBm* 58 dBm @ max. gain ±3 dB 3 msec. (others available on request) 6 dB @ max. gain; 8 dB @ 75 dB gain; 30 dB 15 dB 230 Vac ± 15% / 40.-.65 Hz; Option:24 Vdc or 42 - 60 Vdc or 80 – 130 Vdc, 115 Vac ± 15% / 40.-.65 Hz or 185 – 320 Vac / 40 - 65 Hz 160 Watts SM 2009 7/16 female; N as an option see Environmental and Safety leaflet for MIKOM outdoor cell enhancers Current monitor • synthesizer lock monitor • temperature • ALC active Potential free relay contact and automatic alarm call via RS232 or PCMCIA interface Gain • Center frequency • ALC threshold * Normal temp.range + 5° C to + 40°C Extreme temp.range- 33° C to + 50° C M0079A1A.doc Id.-No. 151775 Page 58 10-March-00 User’s manual for Repeater MRx01B Power ELECTRICAL SPECIFICATIONS Frequency range Id-No:150043 150044 150045 150046 Bandwith Frequency selectivity; Gain outside operating band Gain (nominal) Gain adjust Gain variation over frequ. and temp. Tolerance per step Delay Delayripple Output power ALC limit (test case) at 2 equal carriers ICP3 ALC limit tolerance of frequency and temperature ALC overload reaction time delay Noise figure Test coupler Return loss (@ 25° C amb. temp.) Power Supply Power consumption (1 module) Remote control interface Connectors Environmental and Safety Built in test equipment Alarm forwarding Control functions MR401B Power UL:1710-1740 MHz; DL:1805-1835 MHz UL:1721,7-1751,7MHz; DL:1816,7-1846,7 MHz UL:1730-1760 MHz; DL:1825-1855 MHz UL:1751,5-1784,9 MHz; DL:1846,5-1879,9 MHz Up to 35 MHz ± 400 kHz: 50 dB max.; ± 600 kHz: 40 dB max. ± 1000 kHz: 35 dB max.; ± 5000 kHz: 25 dB max. 85 dB 0 to 30 dB in steps of 2 dB ± 2.5 dB (± 3.5 dB at extreme temperature range)* ± 0.5 dB from 0 to 6 dB attenuation ± 2.0 dB from 8 to 30 dB attenuation 6 µsec.max. 150 ns 30 dBm (@ 25° C) +27,5 dBm / +27,5 dBm* 57 dBm @ max. gain ±3 dB 3 msec. (others available on request) 6 dB @ max. gain; 8 dB @ 75 dB gain; 30 dB 15 dB 230 Vac ± 15% / 40.-.65 Hz; Option:24 Vdc or 42 - 60 Vdc or 80 – 130 Vdc, 115 Vac ± 15% / 40.-.65 Hz or 185 – 320 Vac / 40 - 65 Hz 160 Watts SM 2009 7/16 female; N as an option see Environmental and Safety leaflet for MIKOM outdoor cell enhancers Current monitor • synthesizer lock monitor • temperature • ALC active Potential free relay contact and automatic alarm call via RS232 or PCMCIA interface Gain • Center frequency • ALC threshold * Normal temp.range + 5° C to + 40°C Extreme temp.range- 33° C to + 50° C M0079A1A.doc Id.-No. 151775 Page 59 10-March-00 User’s manual for Repeater MRx01B Power ELECTRICAL SPECIFICATIONS MR701B Power Frequency range Id.No. UL frequency [MHz] 1850 – 1885 1865 – 1890 1875 – 1910 148604 151075 148605 DL frequency [MHz] 1930 – 1965 1945 - 1970 1955 - 1990 Useable bandwidth 35 MHz (25 MHz in 151075) in the upper or lower PCS band Gain 90 dB Gain variation over frequency and temperature* ±2.5 dB (±3.5 dB at extreme temperatures) Gain adjust range 30 dB in 2 dB steps Gain adjust range tolerance ±0.5 dB Return loss 15 dB @ 25°C ambient temperature Spurious/intermodulation -13 dBm max Spectral re-growth (CDMA only) -45 dBc (J-STD-008) Power supply 100-130 VAC / 40-60 Hz Option: 15-24 VDC or 36-72 VDC Option: 220-250 VAC / 40-60 Hz RF connector 7/16 female Option: N female Environmental and safety See separate leaflet *: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°C M0079A1A.doc Id.-No. 151775 Page 60 10-March-00 User’s manual for Repeater MRx01B Power AVAILABLE POWER PER TECHNOLOGY Pout at 1 channel Pout/channel at 2 channels Pout/channel at 4 channels Pout/channel at 8 channels ALC threshold M0079A1A.doc CDMA 37.0 dBm 31.0 dBm 28.0 dBm 25.0 dBm Id.-No. 151775 TDMA 40.0 dBm 34.0 dBm 29.0 dBm 26.0 dBm Adjustable Page 61 GSM 40.0 dBm 37.0 dBm 33.0 dBm 29.0 dBm 10-March-00 User’s manual for Repeater MRx01B Power BAND AND CHANNEL SPECIFICATIONS 3 dB bandwidth Option I (fixed bw) 5 MHz Option II (fixed bw) 15 MHz Slope 3 dB to 30 dB 1 MHz 2 MHz 30 dB bandwith 50 dB bandwith Option III (variable bw) Channel CDMA 1.23 MHz TDMA 30 kHz 2 MHz fc ± 900kHz fc ±60 kHz fc ± 1.5 MHz fc ± 120 kHz Delay 6 µs 3 µs 6 µs < 6 µs 20 µs Delay variation (typical) ±150 ns ±150 ns ±150 ns ±500 ns ±500 ns Far off selectivity 40 dB 40 dB 40 dB 60 dB 55 dB NF at Gmax 6 dB 6 dB 8 dB 6 dB 6 dB NF at Gmax-30 dB 12 dB 12 dB 13 dB 12 dB 12 dB OICP-3 at Gmax 59.0 dBm 59.0d Bm 59.0 dBm 59.0 dBm 59.0 dBm OICP-3 at Gmax 10 dB 58.6 58.5 58.5 58.5 59.0 dBm dBm dBm dBm dBm 58.0 58.0 57.5 58.0 58.5 dBm dBm dBm dBm dBm 56.0 56.0 53.0 55.0 57.0 dBm dBm dBm dBm dBm -78 dBm/Hz -78 dBm/Hz -76 dBm/Hz Output noise out of -98 dBm/Hz -98 dBm/Hz -96 dBm/Hz band at Gmax OICP-3 at Gmax 20 dB OICP-3 at Gmax 30 dB 0.1 to 15 MHz Output noise in band at Gmax Power consumtion standby/max power 1 module (typ.cons) 130/220W 130/220W 145/220W 130/210W 130/210W 4 modules (typ.cons) 160/250W 160/250W 180/270W 160/240W 160/240W M0079A1A.doc Id.-No. 151775 Page 62 10-March-00 User’s manual for Repeater MRx01B Power ELECTRICAL SPECIFICATIONS MR801B Power Frequency range Uplink 824-849 MHz; Downlink 869-894 MHz Useable bandwidth 25 MHz in the upper or lower AMPS 800 band Gain 90 dB Gain variation over frequency and temperature* ±2.5 dB (±3.5 dB at extreme temperatures) Gain adjust range 30 dB in 2 dB steps Gain adjust range tolerance ±0.5 dB Return loss 15 dB @ 25°C ambient temperature Spurious/intermodulation -13 dBm max Spectral re-growth (CDMA only) -45 dBc (J-STD-008) Power supply 115 VAC ± 15% / 40 - 65 Hz Option: 230 VAC ± 15% / 40 - 65 Hz Option: 185 - 320 VAC / 40 - 65 Hz Option: 24 VDC Option: 42 to 60 VDC RF connector 7/16 female Option: N female Environmental and safety See separate leaflet *: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°C AVAILABLE POWER PER TECHNOLOGY Pout at 1 channel Pout/channel at 2 channels Pout/channel at 4 channels Pout/channel at 8 channels ALC threshold M0079A1A.doc CDMA 37.0 dBm 31.0 dBm 28.0 dBm 25.0 dBm Id.-No. 151775 TDMA 40.0 dBm 34.0 dBm 29.0 dBm 26.0 dBm Adjustable Page 63 Analog 40.0 dBm 37.0 dBm 33.0 dBm 29.0 dBm 10-March-00 User’s manual for Repeater MRx01B Power BAND AND CHANNEL SPECIFICATIONS Variable Bandwidth Channel CDMA TDMA 3 dB bandwidth 0.1 to 15.0 MHz 1.23 MHz 30 kHz Slope 3 dB to 30 dB 2 MHz 30 dB bandwith fc ± 900 kHz fc ± 60 kHz 50 dB bandwith fc ± 1.5 MHz fc ± 120 kHz Delay 6 µs < 6 µs 20 µs Delay variation (typical) ±150 ns ±500 ns ±500 ns Far off selectivity 40 dB 60 dB 55 dB NF at Gmax 8 dB 6 dB 6 dB NF at Gmax-30 dB 13 dB 12 dB 12 dB OICP-3 at Gmax 59.0 dBm 59.0 dBm 59.0 dBm OICP-3 at Gmax -10 dB 58.5 dBm 58.5 dBm 59.0 dBm OICP-3 at Gmax -20 dB 57.5 dBm 58.0 dBm 58.5 dBm OICP-3 at Gmax -30 dB 53.0 dBm 55.0 dBm 57.0 dBm -76 dBm/Hz -96 dBm/Hz Power consumtion (standby/max power) 1 module (typ.cons) 145/220 W 130/210 W 130/210 W 4 modules (typ.cons) 180/270 W 160/240 W 160/240 W Output noise in band at Gmax Output noise out of band at Gmax M0079A1A.doc Id.-No. 151775 Page 64 10-March-00 User’s manual for Repeater MRx01B Power ELECTRICAL SPECIFICATIONS MR801Bi Power Frequency range Uplink 806-824 MHz; Downlink 851-869 MHz Useable bandwidth 18 MHz in the upper or lower iDEN band Gain 90 dB Gain variation over frequency and temperature* ± 2.5 dB (± 3.5 dB at extreme temperatures) Gain adjust range 30 dB in 2 dB steps Gain adjust range tolerance ± 0.5 dB Return loss 15 dB @ 25°C ambient temperature Spurious/intermodulation -13 dBm max. Power supply 100 to 130 VAC / 40 - 60 Hz Option: 220 to 250 VAC / 40 - 60 Hz Option: 185 to 320Vac, 40 - 65Hz Option: 24 VDC Option: ± 42 to ± 60VDC Option: ± 80 to ± 130VDC RF connector 7/16 female Option: N female Environmental and safety See separate leaflet *: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°C AVAILABLE POWER PER TECHNOLOGY Pout at 1 channel Pout/channel at 2 channels Pout/channel at 4 channels Pout/channel at 8 channels ALC threshold M0079A1A.doc iDEN 37.0 dBm 31.0 dBm 28.0 dBm 25.0 dBm Id.-No. 151775 Analog 40.0 dBm 37.0 dBm 33.0 dBm 29.0 dBm Adjustable Page 65 10-March-00 User’s manual for Repeater MRx01B Power BAND AND CHANNEL SPECIFICATIONS Variable Bandwidth Channel Selective 0.1* to 15.0 MHz 25 kHz 2 MHz 30 dB bandwith fc ± 60 kHz 50 dB bandwith fc ± 120 kHz 6 µs 20 µs ± 150 ns ± 500 ns Far off selectivity 40 dB 50 dB NF at Gmax 8 dB 6 dB NF at Gmax-30 dB 13 dB 12 dB OICP-3 at Gmax 48 dBm 48 dBm OICP-3 at Gmax -10 dB 48 dBm 48 dBm OICP-3 at Gmax -20 dB 47 dBm 47 dBm OICP-3 at Gmax -30 dB 45 dBm 45 dBm -81 dBm/Hz -101 dBm/Hz Power consumtion (standby/max power) 1 module (typ.cons) 155/220 W 150/210 W 4 modules (typ.cons) 200/265 W 175/240 W 3 dB bandwidth Slope 3 dB to 30 dB Delay Delay variation (typical) Output noise in band at Gmax Output noise out of band at Gmax 1.5 dB gain degradation at 100 kHz M0079A1A.doc Id.-No. 151775 Page 66 10-March-00 User’s manual for Repeater MRx01B Power MECHANICAL SPECIFICATIONS MRx01B Power The MRx01B Power is available in the G-cabinet Max. Height x Width x Depth: 21.1 x 18.2 x 7.9 inches 535 x 462.5 x 200 mm Volume: approximately 45 litres Weight: approximately 103 lbs (47 kg per unit in standard configuration) The illustration of chapter provides the dimensions and the view of the layout. ENVIRONMENTAL AND SAFETY MRx01B Power For detailed information refer to the environmental and safety specification leaflet for MIKOM indoor / outdoor cell enhancers, related to ETS 300019 (European Telecommunication Standard). Operating temperature (normal temperature range): (extreme temperature range): + 5° C ... + 40° C - 33° C ... + 50° C Humidity: + 30° C/ 93 % All data is subject to change without notice ! M0079A1A.doc Id.-No. 151775 Page 67 10-March-00 User’s manual for Repeater MRx01B Power 9.2 Spare parts lists for MRx01B Power The following list contains all parts available for the MRx01B Power. The configuration of the delivered unit meets the requirements of the customer and can differ depending on the state of delivery. 9.2.1 Spare parts list for MR301B Power Designation Id.-No.: 150047 149952 150563 150521 150302 150303 150125 151347 149642 149187 149178 150135 148281 150136 151647 138305 142832 148812 144306 141230 145524 144946 145504 146999 143437 145067 143052 150615 112425 143055 147127 149917 149918 150529 149920 MR301B Power Assembly drawing Assembly drawing (RF-cable plan) Mounting material Duplexer UL Input Duplexer DL Input Bas.Mod.Fix.BW 25,0 MHz Bas.Mod.Fix.BW 15,0 MHz Bas.Mod.Fix.BW 12,5 MHz Bas.Mod.Fix.BW 8,2 MHz Bas.Mod.Fix.BW 6,0 MHz Bas.Mod.Var.BW 25,0 MHz Bas.Mod.Var.BW 10,0 MHz Ext.Mod.Var.BW 10,0 MHz Power Amplifierkit 4W Power Supply, GER plug Power Supply, UK plug Power Supply, no plug Power Supply, no plug Power Supply, USA plug Power Supply, no plug Power Supply, no plug Power Supply, no plug M1 Kit 900 MHz VSWR Kit GSM + EGSM Ext. Alarms SW-Option Battery Backup Module RF Gland / SMA to N Adapter 7 / 16 male - N female SW MOB100 V1.10 SW REP1009 V1.11 Modification Kit 1 channel band selective Modification Kit 2 channels band selective Modification Kit 3 channels band selective Modification Kit 4 channels band selective M0079A1A.doc Id.-No. 151775 Page 68 10-March-00 User’s manual for Repeater MRx01B Power Main Board 12V version Main Board 12V version Control Unit SM2009 Wall mounting kit Sparepart kit Termination Resistor Ready-made cable AC Manual MRx01B Power Manual REP1009V1.xx Additional information Assembly guide MRx01B Power M0079A1A.doc Id.-No. 151775 149780 149779 143051 146179 146200 33167 143032 151775 148964 148222 151045 Page 69 10-March-00 User’s manual for Repeater MRx01B Power 9.2.2 Spare parts list for MR401B Power Designation Id.-No.: MR401B Power Assembly drawing Assembly drawing (RF-cable plan) Mounting material Duplexer UL Input Duplexer DL Input Bas.Mod.Fix.BW 25,0 MHz Power Amplifierkit 4W Power Supply, GER plug Power Supply, UK plug Power Supply, no plug Power Supply, no plug Power Supply, USA plug Power Supply, no plug Power Supply, no plug Power Supply, no plug Ext. Alarms SW-Option Battery Backup Module RF Gland / SMA to N Adapter 7 / 16 male - N female SW MOB100 V1.10 SW REP1009 V1.11 Modification Kit 1 channel band selective Modification Kit 2 channels band selective Modification Kit 3 channels band selective Modification Kit 4 channels band selective Main Board 12V version Main Board 12V version Control Unit SM2009 Wall mounting kit Sparepart kit Termination Resistor Ready-made cable AC Manual MRx01B Power Manual REP1009V1.xx Assembly guide MRx01B Power M0079A1A.doc Id.-No. 151775 150043 150044 150045 150046 149952 150563 150521 150304 150306 150308 150300 150305 150307 150309 150301 150141 151648 138305 142832 148812 144306 141230 145524 144946 145504 145067 143052 150615 112425 143055 147127 149917 149918 149919 149920 149780 149779 143051 146179 146200 33167 143032 151775 148964 151045 Page 70 10-March-00 User’s manual for Repeater MRx01B Power 9.2.3 Spare parts list for MR701B Power Designation Id.-No.: MR701B Power Assembly drawing Assembly drawing RF Assembly drawing (RF-cable plan) Mounting material PCS-Duplexer UL Input PCS-Duplexer DL Input Active Combiner UL Active Combiner DL Bas.Mod.Fix.BW 15,0 MHz Bas.Mod.Fix.BW 5,0 MHz Bas.Mod.Var.BW 15,0 MHz Ext.Mod.Fix.BW 15,0 MHz Basic Module Extension Module Basic Module TDMA Extension Module TDMA Basic Module CDMA Extension Module CDMA Feedforward Amplifier UL Feedforward Amplifier DL Power Supply, GER plug Power Supply, UK plug Power Supply, no plug Power Supply, no plug Power Supply, USA plug Power Supply, no plug Power Supply, no plug Power Supply, no plug Mobile kit PCS Ext. Alarms SW-Option Battery Backup Module Battery Backup Module, Dummy without Accu RF Gland / SMA to N Adapter 7 / 16 male - N female SW MOB100 V1.10 SW REP1007 V1.12 SW REP1009 V1.11 Modification Kit 1 channel band selective Modification Kit 2 channels band selective Modification Kit 3 channels band selective M0079A1A.doc Id.-No. 151775 148604 144382 144381 Page 71 148605 149952 151102 150563 150521 144384 144383 148686 148685 148717 148716 151463 151464 148702 148705 148703 148706 148704 148707 148627 148628 138305 142832 148812 144306 141230 145524 144946 145504 150405 147710 143052 143750 150615 112425 143055 145488 147127 149917 149918 149919 151075 151072 151073 10-March-00 User’s manual for Repeater MRx01B Power Modification Kit 4 channels band selective Modification kit TDMA for 1+2 channel Modification kit TDMA for 3+4 channel Main Board 26V version Main Board 26V version Control Unit SM2009 Wall mounting kit Sparepart kit Termination Resistor Ready-made cable DC Ready-made cable DC act. Com. Ready-made cable AC Manual MRx01B Power Manual REP1007V1.11 Manual REP1009V1.xx Assembly guide MRx01B Power M0079A1A.doc Id.-No. 151775 149920 151135 151136 149778 149777 143051 146179 146200 33167 149648 150753 152024 151775 145956 148964 151045 Page 72 10-March-00 User’s manual for Repeater MRx01B Power 9.2.4 Spare parts list for MR801B Power and MR801Bi Power Designation Id.-No.: MR801B Power / MR801Bi Power Assembly drawing Assembly drawing RF Assembly drawing (RF-cable plan) Mounting material Duplexer UL Input Duplexer DL Input Active Combiner UL Active Combiner DL Bas.Mod.Var.BW 15,0 MHz Ext.Mod.Var.BW 15,0 MHz Basic Module TDMA Extension Module TDMA Basic Module CDMA Extension Module CDMA Basic Module CDMA f1/f2 Basic Module Extension Module Feedforward Amplifier UL Feedforward Amplifier DL Power Supply, GER plug Power Supply, UK plug Power Supply, no plug Power Supply, no plug Power Supply, USA plug Power Supply, no plug Power Supply, no plug Power Supply, no plug Mobile kit PCS, without mobile Mobile kit PCS, with mobile Ext. Alarms SW-Option Battery Backup Module Battery Backup Module, Dummy without Accu RF Gland / SMA to N Adapter 7 / 16 male - N female SW MOB100 V1.10 SW REP1007 V1.12 SW REP1009 V1.11 Modification Kit 1 channel band selective Modification Kit 2 channels band selective Modification Kit 3 channels band selective M0079A1A.doc Id.-No. 151775 148613 151270 149952 151102 150563 150521 148334 148333 148688 148687 148715 148944 148712 148710 148713 148709 152228 148335 148336 148960 148959 150150 150151 150152 150153 151232 151233 148629 148630 138305 142832 148812 144306 141230 145524 144946 145504 150404 150407 147710 143052 143750 150615 112425 143055 145488 147127 149917 149918 150529 Page 73 10-March-00 User’s manual for Repeater MRx01B Power Modification Kit 4 channels band selective Modification kit TDMA for 1+2 channel Modification kit TDMA for 3+4 channel Main Board 26V version Main Board 26V version Control Unit SM2009 Wall mounting kit Sparepart kit Termination Resistor Ready-made cable DC Ready-made cable DC act. Com. Ready-made cable AC Manual MRx01B Power Manual REP1007V1.11 Manual REP1009V1.xx Assembly guide MRx01B Power M0079A1A.doc Id.-No. 151775 149920 151135 151671 149778 149777 143051 146179 146200 33167 149648 150753 152024 151775 145956 148964 151045 Page 74 10-March-00 User’s manual for Repeater MRx01B Power 9.3 Installation drawing of the Repeater figure 9-1 Installation drawing of the Repeater M0079A1A.doc Id.-No. 151775 Page 75 10-March-00 User’s manual for Repeater MRx01B Power 9.4 Top view of the Repeater (left side , exemplary configuration) figure 9-2 Top view of the Repeater (left side, exemplary configuration) M0079A1A.doc Id.-No. 151775 Page 76 10-March-00 User’s manual for Repeater MRx01B Power 9.5 Top view of the Repeater (right side, exemplary configuration) figure 9-3 Top view of the Repeater (right side, exemplary configuration) M0079A1A.doc Id.-No. 151775 Page 77 10-March-00 User’s manual for Repeater MRx01B Power 9.6 One channel configuration – cabling and block diagram figure 9-4 Cabling of one channel Repeater M0079A1A.doc Id.-No. 151775 Page 78 10-March-00 User’s manual for Repeater MRx01B Power figure 9-5 Block diagram of one channel Repeater M0079A1A.doc Id.-No. 151775 Page 79 10-March-00 User’s manual for Repeater MRx01B Power 10 Index Abbreviations 8 Active combiner 22, 56 Alarm monitoring 46 Alarms Acknowledgement of 28 External alarms 30 Handling of 28 Indication of 26 List of all alarms 27 ALC 26 Antenna connectors 38, 39 Antenna isolation 40 AT commands 45 Feedforward amplifier 23 25 Gain Local settings 25, 41 Setting via PC 43 Grounding 37 Health and safety warnings 9 Battery backup 33 BITE 26 46 I²C-Bus 17 Ident numbers 69, 71, 72, 74 Installation Electrical 38 Mechanical 35 Interfaces 17 RS232 17 International sales offices 11 Channel Setting via PC 43 Clamping profile 49 Connector types 7/16 female 39 N female 32 Contents of delivery 8 Control module 17 Configuration 19 conversion module 51 LEDs 26 Local settings 41 Maintenance 48 Measurements of VSWR signals 30 Modem 44 Mother board 15 Mounting brackets 36 DIP-Switch 43 DIP-Switch settings 20 51 Duplexer 14, 21, 51 Optional modules 30 Output DL external 32 EEPROM 17 Environmental and safety 68 M0079A1A.doc Id.-No. 151775 Page 80 10-March-00 User’s manual for Repeater MRx01B Power Setting of operational parameters 40 Setting to work 40 Severity levels 29 Power supply 23 Replacement of 55 Test probes 22 Trouble shooting 46 RAM / RTC battery 50 Remote control 25 Rotary switch To set the gain 42 M0079A1A.doc Id.-No. 151775 Page 81 10-March-00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 81 Creator : Microsoft Word Create Date : Monday, November 06, 2000 11:51:10 AM Title : M0079A1A.PDF Author : Unknown Producer : Acrobat PDFWriter 3.02 for Windows Subject :EXIF Metadata provided by EXIF.tools