Andrew Wireless System IONM171717P ION-M17P/17P/17P Repeater User Manual Additional information on SM2009
Andrew Wireless System ION-M17P/17P/17P Repeater Additional information on SM2009
Contents
- 1. user manual
- 2. Users Manual
Users Manual
Optical Remote Unit ION™-M17P/17P/17P (M-Cabinet) User's Manual MF0143AWA User’s Manual for Remote Unit ION™-M17P/17P/17P © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. No parts of this publication may be reproduced, stored in a retrieval system, transmitted in any form or by any means, electronical, mechanical photocopying, recording or otherwise, without prior written permission of the publisher. Andrew Wireless Systems GmbH, 20-October-2011 Page 2 MF0143AWA.doc TABLE OF CONTENTS 1. GENERAL 1.1. USED ABBREVIATIONS 1.2. HEALTH AND SAFETY WARNINGS 1.3. ABOUT ANDREW SOLUTIONS 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 2. FUNCTIONAL DESCRIPTION 11 2.1. PURPOSE 11 2.2. ION-M17P/17P/17P 11 2.3. 2.3.1. 2.3.2. COMPONENTS OF THE ION-M17P/17P/17P REMOTE UNIT Fan-Protection Kit Accessories 12 12 12 3. COMMISSIONING 14 3.1. 3.1.1. 3.1.2. 3.1.3. 3.1.4. MECHANICAL INSTALLATION General Wall-Mounting Procedure Pole-Mounting Procedure Mounting of Fan Protection 14 14 16 17 19 3.2. 3.2.1. 3.2.2. 3.2.3. 3.2.4. 3.2.5. ELECTRICAL INSTALLATION General Connections Grounding Connection of the Antenna Cables Power Connection 20 20 21 22 23 24 3.3. 3.3.1. 3.3.2. OPTICAL-FIBRE-CABLE CONNECTION - RULES Protective Plug Protective-Tube Kit 25 26 28 3.4. COMMISSIONING 30 4. ALARMS 34 4.1. BITE AND ALARMS 34 4.2. HANDLING OF ALARMS 34 4.3. ALARM STATUS 34 4.4. STATUS LED ALARMS 35 4.5. EXTERNAL ALARM INPUTS AND OUTPUTS 36 4.6. TROUBLESHOOTING 37 5. MAINTENANCE 38 5.1. GENERAL 38 5.2. REPLACING THE FAN UNIT 39 Page 3 User’s Manual for Remote Unit ION™-M9/18P/21P EP 5.3. CLEANING THE HEAT SINK 41 6. APPENDIX 42 6.1. ILLUSTRATIONS 42 6.2. 6.2.1. 6.2.2. 6.2.3. SPECIFICATIONS Electrical Specifications Environmental and Safety Specifications Mechanical Specifications 43 43 43 43 6.3. SPARE PARTS 44 7. INDEX 45 FIGURES AND TABLES figure 3-1 Wall mounting, (metric dimensions).......................................................... 16 figure 3-2 Pole-mounting kit...................................................................................... 17 figure 3-3 Pole mounting (metric dimensions) .......................................................... 18 figure 3-4 Mounting procedure for fan protection, (metric dimensions)..................... 19 figure 3-5 Connector flange of ION-M17P/17P/17P.................................................. 21 figure 3-6 RS232 connector...................................................................................... 22 figure 3-7 Grounding bolt with loosened hex nut ...................................................... 22 figure 3-8 Grounding bolt, schematic view................................................................ 22 figure 3-9 AC mains plug .......................................................................................... 24 figure 3-10 Protective-plug assembly ....................................................................... 26 figure 3-11 Tube-kit installation................................................................................. 29 figure 4-1 Flange connector, 5 poles ........................................................................ 36 figure 4-2 Flange connector, 7 poles ........................................................................ 36 figure 4-3 Alarm inputs and outputs, standard .......................................................... 37 figure 6-1 Installation drawing................................................................................... 42 table 1-1 List of international contact addresses....................................................... 10 table 3-1 Specified torques ....................................................................................... 15 table 3-2 RS232 connector, pin assignment ............................................................. 22 table 4-1 Status LED alarms..................................................................................... 35 Page 4 MF0143AWA.doc 1 General 1. GENERAL 1.1. USED ABBREVIATIONS 3GPP AC AIMOS ALC BITE BTS CE CD CPD DL DoC EDGE EN EP ESD ETS EU FRU GSM GND GUI ICP3 ID No ION IP ISO LED LMT LTE MIMO MS MU NF OTRx PG PIM R&TTE Rev RF RU RX SNMP TS TX UL UMTS UPS VSWR W CDMA WDM 3rd Generation Partnership Project Alternating current / Direct Current Andrew Integrated Management and Operating System Automatic Level Control Built-In Test Equipment Base Transceiver Station "Conformité Européenne" ("European Conformity") Compact Disk Channel Power Detection Downlink Declaration of Conformity Enhanced Data Rates for GSM Evolution European Norm Extension Port Electrostatic Discharge European Telecommunication Standard Extension Unit Field Replaceable Unit Global System for Mobile Communication Ground Graphical User Interface Intercept Point 3rd order Identification Number Intelligent Optical Network Ingress Protection International Organization for Standardization Light Emitting Diode Local Maintenance Terminal Long Term Evolution Multiple Input Multiple Output Mobile Station Main Unit Noise Figure Optical Transceiver = SRMU (Subrack Master Unit) Packing Gland Passive Intermodulation Radio & Telecommunications Terminal Equipment Revision Radio Frequency Remote Unit Receiver Simple Network Management Protocol Technical Specification Transmitter Uplink Universal Mobile Telecommunication System Uninterruptible Power Supply Voltage Standing Wave Ratio Wideband Code Division Multiple Access Wavelength Division Multiplex Page 5 User’s Manual for Remote Unit ION™-M17/17P/17P 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 4. Keep operating instructions within easy reach and make them available to all users. 5. It is the responsibility of the network provider to implement prevention measures to avoid health hazards which may be associated to radiation from the antenna(s) connected to the unit. 6. Note for a Class A digital device or peripheral: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 7. Make sure, access is restricted to qualified personnel. 8. Only licence holders for the respective frequency range are allowed to operate this unit. 9. Corresponding local particularities and regulations must be observed. For national deviations please refer to the respective documents included in the manual CD delivered. 10. Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. 11. Due to power dissipation, the repeater may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Page 6 MF0143AWA.doc 1 General 12. Before opening the unit, disconnect mains. 13. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 14. This unit complies with European standard EN60950. 15. Make sure the repeater settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met. 16. Although the repeater is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the repeater’s antenna connectors for protection against atmospheric discharge. 17. Laser radiation! Do not stare into the beam; do not view it directly or with optical instruments. Page 7 User’s Manual for Remote Unit ION™-M17/17P/17P 1.3. ABOUT ANDREW SOLUTIONS Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage for every application: outdoor use, indoor installations, tunnels, subways and many more. Andrew Wireless Systems GmbH has unparalleled experience in providing RF coverage and capacity solution for wireless networks in both indoor and outdoor environment and belongs to Andrew Solutions, a CommScope Company. Andrew Solutions is the foremost supplier of one-stop, end-to-end radio frequency (RF) solutions. Our products are complete solutions for wireless infrastructure from top-of-the-tower base station antennas to cable systems and cabinets, RF site solutions, signal distribution, and network optimization. Andrew Solutions has global engineering and manufacturing facilities. In addition, it maintains field engineering offices throughout the world. We operate a quality management system in compliance with the requirements of ISO 9001. All equipment is manufactured using highly reliable material. In order to ensure constant first-rate quality of the products, comprehensive quality monitoring is conducted at all fabrication stages. Finished products leave the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal operation. Note: Exceptions of and national deviations from this intended use may be possible. To observe corresponding local particularities and regulations, please refer to the respective documents (also in national language) which are included in the manual CD delivered. To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions. For technical assistance and support, please also contact the local office or Andrew Solutions directly at one of the addresses listed in the following chapter. Page 8 MF0143AWA.doc 1 General 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT Americas: Canada United States Andrew Solutions Canada Andrew Solutions, Andrew LLC, A CommScope Company Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Phone +1-905-878-3457 (Office) +1-416-721-5058 (Mobile) Phone +1-888-297-6433 Fax +1-905-878-3297 Fax +1-919-329-8950 E-mail Peter.Masih@commscope.com, WIsupport.us@commscope.com E-mail WIsupport.us@commscope.com Brazil & South America Mexico, Central America & Caribbean region CommScope Cabos do Brasil Ltda. Andrew Corporation Mexico, SA DE CV Mail Av. Com. Camilo Julio 1256 Zonal Industrial CP 597 Sorocaba SP 18086-000 Brazil Mail Av. Insurgentes Sur 688, Piso 6 Col. Del Valle, CP: 03100 Mexico City Mexico Phone + 55-15-9104-7722 Phone +52-55-1346-1900 (Office) +52-1-55-5419-5260 (Mobile) Fax + 55-15-2102-4001 Fax +52-55-1346-1901 E-mail WIsupport@commscope.com E-mail WIsupport@commscope.com APAC Countries: China, India and Rest of Asia Andrew International Corporation Australia & New Zealand Andrew Corporation (Australia) Pty Ltd. Mail Room 915, 9/F Chevalier Commercial Centre 8 Wang Hoi Rd Kowloon Bay Hong Kong Mail Unit 1 153 Barry Road Campbellfield VIC 3061 Australia Phone +852-3106-6100 Phone +613-9300-7969 Fax +852-2751-7800 Fax +613-9357-9110 E-mail WIsupport.China@commscope.com E-mail WIsupport.Australia@commscope.com Page 9 User’s Manual for Remote Unit ION™-M17/17P/17P Europe: United Kingdom France Andrew Solutions UK Ltd CommScope France Mail Unit 15, Ilex Building Mulberry Business Park Fishponds Road Wokingham Berkshire RG41 2GY England Mail Immeuble Le Lavoisier 4, Place des Vosges 92052 Courbevoie France Phone +44-1189-366-792 Phone +33-1 82 97 04 00 Fax +44-1189-366-773 Fax +33-1 47 89 45 25 E-mail WIsupport.uk@commscope.com E-mail WIsupport@commscope.com Germany Czech Republic Andrew Wireless Systems GmbH Andrew Solutions Czech Republic C-Com, spol. s r.o Mail Industriering 10 86675 Buchdorf Germany Mail U Moruší 888 53006 Pardubice Czech Republic Phone +49-9099-69-0 Phone +420-464-6280-80 Fax +49-9099-69-930 Fax +420-464-6280-94 E-mail WIsupport@commscope.com E-mail WIsupport@commscope.com Austria Switzerland Andrew Wireless Systems (Austria) GmbH Andrew Wireless Systems AG Mail Weglgasse 10 2320 Wien-Schwechat Austria Mail Tiergartenweg 1 CH-4710 Balsthal Switzerland Phone +43-1706-39-99-10 Phone +41-62-386-1260 Fax +43-1706-39-99-9 Fax +41-62-386-1261 E-mail WIsupport.austria@commscope.com E-mail WIsupport.ch@commscope.com Italy Spain and Portugal Commscope Italy S.r.l., Faenza, Italy Andrew Solutions España S.A. A Commscope Company Mail Via Mengolina, 20 48018 Faenza (RA) Italy Mail Avda. de Europa, 4 - 2ª pta. Parque Empresarial La Moraleja 28108 Alcobendas (Madrid) Spain Phone +39-0546-697111 Phone +34-91-745-20 40 Fax +39-0546-682768 Fax +34-91-661-87 02 E-mail WIsupport.italia@commscope.com E-mail WIsupport.iberia@commscope.com table 1-1 List of international contact addresses Page 10 MF0143AWA.doc 2 Functional Description 2. FUNCTIONAL DESCRIPTION 2.1. PURPOSE Cellular telephone systems transmit signals in two directions between base transceiver station (BTS) and mobile stations (MS) within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distribution system. Such a system contains an optical Master Unit and several Remote Units. The number of the Remote Units depends on the hardware and software configuration. The Remote Units are connected to the Master Unit with optical links. The optical loss must be less than 10 dB inclusive optical couplers or splitters. The Master Unit is the connection to the base transceiver stations. The configuration of a Master Unit depends on the number of the Remote Units and the frequency range. WDM (Wave Division Multiplex) filters are integrated in the optical modules. For the UL, a wavelength within 1540 nm – 1562 nm is used. For the DL, a wavelength of 1310 ±20 nm is used. The maximum output power for the UL and DL is 5.7 mW. 2.2. ION-M17P/17P/17P Andrew Solutions ION-M17P/17P/17P is a 3 sector single-box remote unit. It is used in conjunction with a master unit in the ION optical distribution system. This system transports 3 sectors (3 x 1700/2100 MHz) simultaneously, providing a cost-effective solution for distributing capacity from one or more base stations. The ION-M17P/17P/17P transports signals on the RF layer in a very inexpensive manner. This means that multiple operators and multiple technologies are moved simultaneously from a cluster of base stations to a remote location over the same fibre. The ION optical distribution system is a cost-effective coverage solution for dense urban areas, airports, high-rise buildings and other locations where physical structures increase path loss or provide limited space for installation. It has been specifically designed to reduce zoning problems and to provide homogeneous coverage. The compact, mechanical design is specifically architected to mount inside of or on poles and along side structures in such a way that it has a minimal visual impact. The ION-M platform has been specifically tested and optimized for CDMA2000. Furthermore, it is provisioned for future improvements to the modulation and frequency bands. Page 11 User’s Manual for Remote Unit ION™-M17/17P/17P The ION is easily set-up and supervised via a graphical user interface (GUI). Remote units can be commissioned through the use of built-in test equipment. An autolevelling function compensates for the optical link loss making installation easy and quick. The entire system may be monitored remotely via an Andrew OMC. This is a comprehensive management platform with SNMP protocol and X.733 standard implemented. Should a sophisticated interface not be required, the master unit can be directly connected to the alarm interface of a base station via relay alarming. 3 sector multi-operator support Reduced visual impact form factor Efficient, high power amplifier Single fibre for multiple sectors Comprehensive operations and management system for configuration and alarming OMC with SNMP according to X.733 standard Easy installation and commissioning 2.3. COMPONENTS OF THE ION-M17P/17P/17P REMOTE UNIT 2.3.1. Fan-Protection Kit In order to protect the fan unit (e.g. against rain), a protective cover to be mounted over the air inlet is delivered with the unit. For indoor applications, mounting of the fan-protection kit is not mandatory. For more details see chapter 3.1.4 Mounting of Fan Protection. 2.3.2. Accessories For the accessories available for the remote unit, e.g. overcoat housing, connecting box or iso-trafo kit, a separate manual is available. Page 12 MF0143AWA.doc 2 Functional Description For your notes: Page 13 User’s Manual for Remote Unit ION™-M17/17P/17P 3. COMMISSIONING 3.1. MECHANICAL INSTALLATION 3.1.1. General Read the health and safety warnings in chapter 1.2. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. It is recommended only to use the mounting hardware delivered by the supplier. If different mounting hardware is used, the specifications for stationary use of the Remote Unit must not be exceeded. Note: Exceeding the specified load limits may cause the loss of warranty! 3. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation as specified in the individual mounting procedures. 5. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables. 6. Also observe all additional rules or restrictions regarding mounting that depend on the type of Remote Unit. For details refer to chapter 7.2.2 Mechanical Specification. Install the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical position must be kept, as in the following illustrations: Page 14 MF0143AWA.doc 3 Commissioning 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 17 x 17 cm (290 cm2). Make sure, too, there is no thermal short circuit between the air inlet and air outlet. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques have to be observed for certain mounting procedures according to the following table: Type Thread Specified torques Lens head screws M4 3.3 Nm Hex Spacing PG PG nuts bolts (plastic) (aluminium) M8 M4 M8 PG 13.5 PG 29 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm table 3-1 Specified torques Note: To avoid damage when mounting the unit, always make sure that the M8 washers (DIN9021 or DIN125 depending on the mounting kit) are placed behind and in front of the mounting drillings of the unit. The mounting procedures for a stand-alone Remote Unit without optional accessories are described and illustrated in the following sections. For further information regarding special mounting procedures including mounting of accessory equipment, please see separate manual. Page 15 User’s Manual for Remote Unit ION™-M17/17P/17P 3.1.2. Wall-Mounting Procedure Check the suitability of the wall-mounting kit and the wall. Mark the position of the drilling holes (for measurements refer to figure 3-1 Wall mounting). Drill four holes at the marked positions and insert dowels *. Use a cap nut or lock nut to screw the four dowel screws into the dowels and put the distance tubes over the screws. Hang the mounting brackets of the Remote Unit into the screws, and fasten them immediately using the washers and nuts. Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded. 4.0 0.50 122 ± 0.50 80 ± 0.50 18 796 ± 1.00 Wall mounting with active cooling kit Mains supply G0946Z0 figure 3-1 Wall mounting, (metric dimensions) * The dowels are not part of the delivery since the suitable type depends on the on-site conditions (material of wall). Therefore, use dowels that are appropriate for the mounting surface. Page 16 MF0143AWA.doc 3 Commissioning 3.1.3. Pole-Mounting Procedure Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a column or other similar structures. Additional hardware must be used for this type of installation. Such a pole-mounting kit could include two threaded rods M8, two U-beams and mounting material like bolts and nuts. figure 3-2 Pole-mounting kit Use the screw bands to fasten the two U-beams to the pole as illustrated in figure 3-3 Pole mounting. Note: When fastening the U-beams make sure that they are installed congruently and not at an angle to each other. To determine the distance between the beams refer to 3.1.2 Wall-Mounting Procedure for measurements. Hang the mounting brackets of the Remote Unit into the threaded bolts of the U-beam, and fasten them immediately using the washers and nuts. Ensure that there is free access to the electrical connections as well as to the cabinet. The approved bending radius of the connected cables must not be exceeded. Page 17 User’s Manual for Remote Unit ION™-M17/17P/17P Lock for folding screw band ES 119 TESPA screw band, stainless, 11 mm Optical Remote Unit Washer DIN 125 Form B Ø 8.0 Lock washer for M8.0 DIN 127 A2 Form B Hexagon nut M8 DIN 934 Ø40 Ø140 Pole Pole Pole-mounting bracket G0764M6 figure 3-3 Pole mounting (metric dimensions) Page 18 MF0143AWA.doc 3 Commissioning 3.1.4. Mounting of Fan Protection Since the fan protection is required for the outdoor usage of a stand-alone Remote Unit, the mounting of this optional equipment is also described in this manual. To install the protective cover of the fan protection kit, first unscrew the four screws with the respective lock washers from the cover of the air inlet of the Remote Unit, and instead, screw in the four spacing bolts M4.0x30 with the four lock washers M4.0 DIN125 that are part of the fan protection kit. Place the protective cover into the right position by fitting its four bore holes over the spacing bolts and fasten it using the original lock washers and screws of the Remote Unit. (These lock washers and screws are also part of the fan protection kit and can be used as spare parts in case of loss.) remove the screw and the lock washer! 2x M4.0x8 fillister-head screws remove the screw and the lock washer! 2x M4.0x8 fillister-head screws 2x lock washers 2x lock washers 2x washers 2x M4.0x8 fillister-head screws AIR STREAM 2x M4.0x30 spacing bolts 1x rain protective cover 2x lock washers 2x washers 2x M4.0x8 fillister-head screws 2x M4.0x8 fillister-head screws 156 152 171 2x lock washers 20 remove the screw and the lock washer! G0496MF figure 3-4 Mounting procedure for fan protection, (metric dimensions) Page 19 User’s Manual for Remote Unit ION™-M17/17P/17P 3.2. ELECTRICAL INSTALLATION 3.2.1. General Read the health and safety warnings in chapter 1.2. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed. 2. It is compulsory to ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Although the Remote Unit is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is strongly recommended to insert additional lightning protection. 4. If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains circuit must be provided within easy reach. 5. Before connecting or disconnecting the mains connector at the Remote Unit, ensure that mains supply is disconnected. 6. Make sure that an appropriate circuit breaker and an overcurrent limiting device are connected between mains and Remote Unit. 7. A connection of mains supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew ecatalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. 11. For unstabilized electric networks which frequently generate spikes, it is advised to use a voltage limiting device. 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection) depending on the individual application in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. Page 20 MF0143AWA.doc 3 Commissioning 3.2.2. Connections Mains connector Status LED N-connector mobile Sector 3 External alarm input Alarm output N-connector mobile Sector 2 Control connector Grounding bolt Optical-fibre connector N-connector mobile Sector 1 figure 3-5 Connector flange of ION-M17P/17P/17P Page 21 User’s Manual for Remote Unit ION™-M17/17P/17P Control Connector RS232 - Local Interface This 8-pin male connector (type: Binder Series 712) is primarily to support local control of the remote unit via RS232 ASCII interface. PIN figure 3-6 RS232 connector Assignment Not connected (n.c.) RS232 Rx RS232 Tx n.c. GND* (RS232) n.c. n.c. n.c. table 3-2 RS232 connector, pin assignment * GND is the abbreviation of Ground 3.2.3. Grounding Grounding must be carried out. Connect an earth-bonding cable to the grounding connection provided at the outside of the remote unit (see chapter 3.2.2 Connections). Do not use the grounding connection to connect external devices. figure 3-7 Grounding bolt with loosened hex nut figure 3-8 Grounding bolt, schematic view After loosening the hex nut, connect the earth-bonding cable between the two washers as illustrated in the figures above. Then, fasten all parts again with the hex nut. Page 22 MF0143AWA.doc 3 Commissioning 3.2.4. Connection of the Antenna Cables The Remote Unit has N-type antenna connectors. For its location please refer to chapter 3.2.2 Connections. For mounting the cable connectors, it is recommended to refer to the corresponding documentation of the connector manufacturer. The bending radius of the antenna cables must remain within the given specifications. For the selection of cable and antenna it should be considered that, on the one hand, a cable with higher loss is less expensive but, on the other hand, it impairs performance. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the Andrew e-catalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. To minimize passive inter-modulation (PIM) distortion, attention has to be paid to the physical condition of the connector junctions. Do not use connectors that show signs of corrosion on the metal surface. Prevent the ingress of water into the connector. Attach and torque the connectors properly. Page 23 User’s Manual for Remote Unit ION™-M17/17P/17P 3.2.5. Power Connection Before connecting electrical power to the units, the system must be grounded as described in the previous chapter. Mains power must be connected at the mains connector of the unit (see chapter 3.2.2 Connections). The power supply plug is part of the delivery. The correct wiring of the power supply plug is as follows: figure 3-9 AC mains plug For the AC power supply connection, a minimum cross section of 1.5 mm2 is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. Note: Do not connect or disconnect the power cord at the mains connector while power is on. Turn off mains * power before connecting the power cord at the remote unit, then, engage mains again. * Mains power must be interruptible with an external mains breaker. For the mains breaker, observe the following recommendation: 120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240-Volt service. Page 24 MF0143AWA.doc 3 Commissioning 3.3. OPTICAL-FIBRE-CABLE CONNECTION - RULES Optical signals are transmitted by use of optical fibres. When connecting these fibres observe the following instructions. Note: Care should be taken when connecting and disconnecting fibreoptic cables. Scratches and dust significantly affect system performance and may permanently damage the connector. Always use protective caps on fibre-optic connectors not in use. In general, optical fibres do not need special protective measures. However, protection against environmental influences e.g. rodents and humidity must be considered. The optical fibre is a single mode fibre. Type is E9/125 µm with the following minimum requirements: Attenuation: <0.36 dB / km @ 1310 nm Dispersion: <3.5 ps / nm km @ 1310 nm <0.26 dB / km @ 1550 nm <18.0 ps / nm km @ 1550 nm The specified bending radius of the optical fibres must not be exceeded. The pigtails for the connection between master unit and remote unit must have a sufficient length. A protection for the feeding into units must be given. The system attenuation of the optical fibres, including the connectors, must not exceed 10 dB. System attenuation and attenuation of optical components must be determined. This can be achieved by measuring attenuation and reflection with an appropriate measuring instrument. For pigtails, a total value of < 0.4 dB (measured to a reference plug) can be assumed due to the dead zone of the reflectometer. These measurements must be made with a sufficient length of optical fibre, at the input and output of the device which has to be measured. Fibre-cable connectors have to be of the same type (E2000APC8°) as the connectors used for the unit. The fibre-optic cables are connected to the optical transceiver. Angled connectors are not compatible with straight optical connectors; non-compatibility of connectors will result in permanent damage to both connectors. Before connecting the fibre cables, follow the procedure below to ensure optimized performance. It is important for these procedures to be carried out with care: Page 25 User’s Manual for Remote Unit ION™-M17/17P/17P Remove fibre-optic protective caps. Do not bend the fibre-optic cable in a tight radius (< 4 cm) as this may cause cable damage and interrupt transmission. Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of the fibre-optic cable that will be inserted in the optical connectors on the donor interface box. Blow out the laser receptacle with clean and dry compressed air to remove any particulate matter. Connect the fibre-optic cables by inserting the cable end into the laser receptacle and aligning the key (on the cable end) with the keyed slot. Do not use any index-matching gels or fluids of any kind in these connectors. Gels are intended for laboratory use and attract dirt in the field. 3.3.1. Protective Plug Connection: A protective plug is provided for the connection of the fibre-optic cables. figure 3-10 Protective-plug assembly Note: Page 26 Only high-quality connectors must be used for this type of plug. Qualified brands are Diamond or Huber & Suhner. MF0143AWA.doc 3 Commissioning For plug assembly, observe the following instruction: 1. Pass one or two contacts through the backshell and the clamp ring. 2. Place the contact(s) on the lower insulation body by pushing the groove of the contact into the cavity. If there is only one contact, cavity A must be used. * 3. Then, mount the upper insulation body on the lower insulation body. ** Upper insulation body Cavity B Cavity A 4. Bring the insulator into the plug. The narrow groove of the insulator must be fitted into the stamp of the plug. ** To release the contact for disassembling, push the inner snap to the side and pull the contact out. To release upper and lower insulation bodies for disassembling, use a small screwdriver and carefully open the snap-connections at the left and the right side of the insulator without damaging them. 5. Fasten the insulator by screwing the 6. Place the appropriate seal parts (with backshell tight onto it. Use a spanner one groove for one contact or two with opening 32 to screw the grooves for two contacts) over the backshell tight (no gap). cable(s) and push them into the backshell. No gap Seals with one groove Page 27 User’s Manual for Remote Unit ION™-M17/17P/17P 7. Bring the plastic ring over the cable(s), push it into the backshell and compress the seals and plastic ring by screwing the clamp ring tight (no gap) using a spanner with opening 20. *** Screw tight until gap is closed 8. Connect the plug to the optical-fibre 9. To lock the connector, push the black connector of the remote unit, again by locking ring forward.**** fitting a stamp on the plug into the groove of the connector. Groove Push forward to lock, pull back to free connection *** For disassembling, release the clamping ring and remove the seals and the plastic ring first. **** Locking mechanism: The system of locking the plug is based on a “push-pull” mechanism. The locking ring has to be pushed forward to lock the connector and pulled back to free the connection. 3.3.2. Protective-Tube Kit As additional protection for the optical fibers, this connector type can be supplemented by a special tube kit. To fasten the tube correctly, first unscrew the clamp ring (if already installed) of the original plug kit. Then, proceed according to the following instruction: Page 28 MF0143AWA.doc 3 Commissioning Protective plug Fiber cable Ring 3/4 Reducer Screw the reducer to the protective plug backshell without any gap! Coupling Place the appropriate seal parts (with) one groove for one contact or two grooves for two contacts) over the cable(s) and push them into the backshell! Protective tube Push the fiber-optic cable carefully through the tube until it comes out at the other end. G1055M0 figure 3-11 Tube-kit installation Page 29 User’s Manual for Remote Unit ION™-M17/17P/17P 3.4. COMMISSIONING Read the health and safety warnings in chapter 1.2 as well as the description carefully to avoid mistakes and proceed step by step as described! Do not operate the remote unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load. Only qualified personnel should carry out the electrical, mechanical, commissioning and maintenance activities that require the unit to be powered on when open. When opening the remote unit do not damage the warranty labels on the internal devices. The warranty is void if the seals are broken. Ensure that all connections have been performed according to chapter 3.2.2 Connections. Page 30 MF0143AWA.doc 3 Commissioning Commissioning an ION-M Remote Unit Manual for Remote Unit Philips screwdriver Mounting kit Spanner, size 13 mm Drilling machine Dowels Screw driver Screw driver Spanner, size 13 mm Start Preperation Unpack RU, RU accessories and mounting kit. Mechanical installation Fasten wall or pole mounting kit to wall or pole. Mechanical installation Mount RU to mounting kit, ensure suffient air flow and avoid thermal short circuits. Grounding cable Spanner 13 mm Electrical connections Connect grounding cable and ground the RU. Alarm kit (M-cabinet) External devices Connect external devices to the external in or alarm out connectors, or to the connecting board inside the RU. RF connection Connect antenna cable to antenna port. Optical connections Mount the optical fibre with E2000 APC8° connector into the connector. Plug the connector into the RU. E2000 APC8° connector Spanner with opening 32 Mains cable Connecting kit Electrical connections Connect AC (DC) power to the power cable. Ensure there is a circuit breaker between mains and RU. G1055Z0 G1055Z0 Mains Switch mains power on. Page 31 User’s Manual for Remote Unit ION™-M17/17P/17P LED on? No Check power switch inside RU (RUs with door). Check mains cabling. Check mains power. Yes LED status Red Internal Error Change power supply (RUs with a door). Reduce environmental temperature. Eliminate thermal short circuit. Disconnect and connect mains. Fans should run. If not, replace the fans at RU. MU: Change amplifier setting at MU controller Orange Yellow Yes LED status Red Green Spare RU available? External error Close the door (RUs with a door). Check externally connected devices. Check fibre loss of optical link. Check optical connectors. Clean optical connectors. Check optical output power of corresponding OTRx at master unit. ALC alarm: Decrease DL input power of affected band. VSWR alarm: Check antenna and cable. Green No Contact customer service Finished setting up all RUs? No Yes Proceed to MU to set up the SW Go to MU Page 32 Output: All RUs okay. MF0143AWA.doc 3 Commissioning For your notes: Page 33 User’s Manual for Remote Unit ION™-M17/17P/17P 4. ALARMS 4.1. BITE AND ALARMS The Built-In Test concept comprises the monitoring of the power supplies, the power amplifiers and the optical interface. All occurring alarms can be checked via software at the master unit. 4.2. HANDLING OF ALARMS As soon as the software acknowledges a valid alarm, a message is transmitted to the master unit. If the reason for the alarm has been cleared or if the alarm should continue, a new alarm message will not be repeated. If there was an interruption of at least five seconds after acknowledgement, a new alarm message will be generated. 4.3. ALARM STATUS For details refer to the corresponding software documentation of the master unit. Page 34 MF0143AWA.doc 4 Alarms 4.4. STATUS LED ALARMS For local supervision, a status LED on the connector flange of the remote unit gives an indication of possible reasons for alarms. This table shows possible on-site measures that could be checked before referring to the master unit alarm list. Status LED Indication Green Orange Red Status LED off Alarms Possible on-site measures No alarm Status ok Door alarm Close the door (RUs with door). Alarms not directly related to RU: External alarms Check externally connected devices. Check fibre loss of optical link. Check optical connectors. Optical alarm Rx Clean optical connectors. (MU: Check optical output power of corresponding OTRx at master unit). (MU: Decrease DL input power of ALC alarm affected band). Alarms directly related to RU: Change power supply (RUs with door). Power 28 V Replace the affected remote unit. Reduce environmental temperature. Temperature Eliminate thermal short circuit. Disconnect and connect mains. Fans Fan should run. If not, replace the fans at RU. I²C Disconnect and connect mains. Optical alarm Tx Amplifier “Power (MU: Change amplifier setting at MU Down” controller). Check power switch inside of RU (RUs with door). Mains Check mains cabling. Check mains power. table 4-1 Status LED alarms For the position of the status LED see chapter 3.2.2 Connections. Explicit troubleshooting is available in the MU software (software manual or WEB Interface). Page 35 User’s Manual for Remote Unit ION™-M17/17P/17P 4.5. EXTERNAL ALARM INPUTS AND OUTPUTS G1038Z0 figure 4-1 Flange connector, 5 poles G1038Z0 figure 4-2 Flange connector, 7 poles The alarm outputs (open collector output 5 V / 1 mA) are normally low. In case of an alarm they are high active (5 V). They can be used to monitor alarms with an external alarm indicator. The +28 V pin (for its location see figure 4-2 Flange connector, 7 poles) is protected by a 500mA thermoswitch. In case of exceeding this current between pin 7 and GND and/or in case of a failure of the VSWR module, the thermoswitch turns into a highresistive status. In this case no fuse needs to be replaced. Just wait a few minutes until the thermoswitch reaches the normal operating temperature again. Note: The manufacturer / supplier of this system accepts no liability for damage caused by equipment connected to external outputs or by effects from such equipment. As accessory equipment the alarm kit (see chapter 6.3 Spare Parts) is available to connect external devices to the external alarm inputs and outputs.. Page 36 MF0143AWA.doc 4 Alarms With the external alarm inputs it is possible to monitor the status of connected devices, e.g. a UPS, via software. All alarm inputs are normally high (5 V) without connection. The polarity (high/ low) can be set via the software at the Master Unit (for details please see according software manual). The device to be monitored must be connected so that the alarm contacts will be closed in case of an alarm (I max = 8 mA). The alarm inputs are potential-free with common ground. Subminiature circular connectors series 712 with five and seven contacts, which are contained in the alarm kit, can be ordered directly from the Binder Connector Group, the manufacturer, or indirectly from Andrew Solutions (see chapter 6.3 Spare Parts). ION-M alarm inputs ION-M alarm outputs +5 V +5 V 560R 4700R Alarm output Alarm input Alarm GND Alarm GND Alarm GND Alarm GND V1651A1 figure 4-3 Alarm inputs and outputs, standard 4.6. TROUBLESHOOTING The status of the remote unit can be checked via the master unit (for details please refer to the software manual of the Master Controller). Locally, the status can be checked at the LED, see chapter 4.4 Status LED Alarms. Page 37 User’s Manual for Remote Unit ION™-M17/17P/17P 5. MAINTENANCE 5.1. GENERAL Read the health and safety warnings in chapter 1.2. Note: The remote unit does not require preventative maintenance measures. Note: To prevent malfunctions of the cooling system due to dirt or pollution, it is recommended to clean the heat sink at regular intervals. These cleaning intervals depend mainly on the location of the remote unit and the corresponding degree of pollution. Maintenance of the ION-M17P/17P/17P should be performed by replacing only components that are contained in this chapter. In order to maintain warranty, take care not to damage unintentionally the seals on the modules. The spare parts list, consequently, contains only units which can be replaced without tuning or soldering work. Note: When sending back the unit, use an appropriate packaging, see chapter 6.2.2 Environmental and Safety Specifications. We strongly recommend using the original packaging! Note: Defect parts should only be replaced by original parts from the supplier. All interventions inside the housing are at one’s own risk. Note: During maintenance ensure disconnected from mains. Note: Before disconnecting any cables, label any unlabelled cables to ensure correct connection. the remote unit has been For most maintenance procedures appropriate tools are required to ensure correct handling. All these tools can be ordered from the supplier. For screwing procedures observe that all our screws have a right-hand thread, i.e. for fastening the screws turn the tool clockwise and for unscrewing them turn it counter-clockwise. Due to the design of the remote unit the only component recommended to be replaced is the fan unit. For replacing any other component, please contact the supplier. Page 38 MF0143AWA.doc 5 Maintenance 5.2. REPLACING THE FAN UNIT Replacement of the fan unit is not required as a preventative measure. Only when an alarm indicates a malfunctioning of a fan, must the unit be exchanged. Note: Please observe that the fan unit can only be replaced as a whole. Do not remove the fans separately. Read the health and safety warnings in chapter 1.2 as well as the instructions in chapter 5.1 General before starting with the replacement. 1. Switch off the remote unit. Make sure mains is disconnected for the following replacement procedure. Then, proceed as follows: 2. Loosen the four tallow-drop screws M4x8 by which the fan plate is screwed to the cabinet. Remove the four screws and the corresponding washers. 3. Remove the fan unit – by putting slight pressure on the fan plate cover – to a position that allows access to the fan connector and the earth-bonding cable. 4. Unscrew the fan connector and then disconnect the earth-bonding cable. Fan-unit connector Earth-bonding cable Note: To observe the specified torque of 650 Ncm for an M5 thread, use an appropriate tool for the following screwing procedures. Page 39 User’s Manual for Remote Unit ION™-M17/17P/17P 5. To mount the new fan unit, re-connect the earth-bonding cable and the fan connector (see step 4). Then, place the fan unit back into its original position and fix it tight as shown below: 6. Screw the whole fan unit to the cabinet with the four tallow-drop screws M4x8 (see step 2). In order not to exceed the specified torque of 330 Ncm, use an appropriate tool. Page 40 MF0143AWA.doc 5 Maintenance 5.3. CLEANING THE HEAT SINK Note: Read the health and safety warnings in chapter 1.2 as well as the instructions in chapter 5.1 General before starting with the replacement procedure. Then, proceed as follows: 1. Switch off the remote unit. Make sure that mains is disconnected for the following procedure. 2. Remove the fan plate with the fan unit 3. Use compressed air (max. 5 bar) to from the remote unit as described in blow out the heat sink from back to chapter 5.2 Replacing the Fan Unit, front: steps 1 and 2: Compressed air (5 bar max.) Brush (not metallic) 4. In case the dirt cannot be blown out completely and parts of it stick to the ribs of the heat sink, clean the parts concerned carefully from the front using e.g. a brush. Take care that the material is not scratched or damaged. 5. After cleaning the heat sink, mount the fan unit again according to chapter 5.2 Replacing the Fan Unit, step 6. Then, switch the remote unit back on. Page 41 User’s Manual for Remote Unit ION™-M17/17P/17P 6. APPENDIX 6.1. ILLUSTRATIONS figure 6-1 Installation drawing Page 42 MF0143AWA.doc 6 Appendix 6.2. SPECIFICATIONS 6.2.1. Electrical Specifications ION-M17P/17P/17P Electrical Mains power 85 to 264 Vac Power supply Idle approx. 330 watts Power consumption Full load 800 watts Optical Connectors E2000/APC 8° Optical return loss 45 dB minimum Fiber type Single mode E9/125 µm Optical link budget 0 to 10 dB Composite input power 2100 MHz +3 dBm nominal @ Conversion module master side +10 dBm max 1) -19 dBm min 2) 1) 2) can be compensated by additional attenuation (0 - 7 dB) can be compensated by additional gain (0 - 22 dB) All data is subject to change without notice. 6.2.2. Environmental and Safety Specifications Note: For detailed information, please refer to the Environmental and Safety Specifications leaflet of the supplier, related to ETS 300 019 (European Telecommunication Standard). Operating temperature range RF part Ingress protection Fan part -33° C to +50° C IP67 IP55 All figures are typical values unless otherwise stated. All data is subject to change without notice. 6.2.3. Mechanical Specifications Height, width, depth ** Weight ** 831 x 156 x 147 mm (32.7 x 6.1 x 5.8 in) 18 kg (39.7 Ib) Spacing required 40 mm (1.58 in) around unit All data is subject to change without notice. Page 43 User’s Manual for Remote Unit ION™-M17/17P/17P 6.3. SPARE PARTS The following list contains all parts available for the Remote Unit. The configuration of the delivered unit meets the requirements of the customer and can differ depending on the state of the delivery. Maintenance of the ION-M17P/17P/17P should be performed on an FRU (Field Replaceable Unit) basis only. Do not damage the warranty labels on the components, as this voids the warranty. If any FRU not contained in the following list needs to be replaced, please contact customer service for additional instructions. Spare Parts List of the Remote Unit ION-M17P/17P/17P Designation: ID No: ION-M17P/17P/17P Protective Plug E 2000 Protective Cap E 2000 Fan Protection Kit Fan Unit Protective Tube Kit Manuals for Optical Remote Unit ION-M17P/17P/17P 7634986 7160013 7158914 7159097 7158254 7162182 7619958-00 Accessories Alarm Kit 7157396 Wall Mounting Wall-Mounting Kit ISO Trafo Kit 115 V Wall Mounting ISO Trafo Kit 230 V Wall Mounting Connecting Box Kit Wall Mounting Overcoat Housing Kit Wall Mounting Pole Mounting Pole-Mounting Kit ISO Trafo Kit 115 V Pole Mounting ISO Trafo Kit 230 V Pole Mounting Connecting Box Kit Pole Mounting Overcoat Housing Kit Pole Mounting 7158078 7159340 7158322 7159613 7159625 7157782 7159623 7159621 7159612 7159624 The manufacturer reserves the right to replace the spare parts listed above by equivalent substitutes. Note: Only the spare parts listed above are FRUs (= Field Replaceable Units) and can be replaced by the user. For replacement of any other parts, please send the entire Remote Unit back to the manufacturer. Page 44 MF0143AWA.doc 7 Index 7. INDEX Address of Andrew Wireless Systems GmbH....... 10 Alarms Alarm Status .................................................... 35 Bite and Alarms ............................................... 35 External Inputs........................................... 37, 38 Handling of Alarms .......................................... 35 List ................................................................... 38 Outputs ...................................................... 37, 38 RU ................................................................... 38 Status LED....................................................... 35 Andrew Solutions.................................................... 8 Health and Safety Warnings................................... 6 Cleaning the Heat Sink ......................................... 42 Commissioning General ............................................................ 31 Components Accessories ..................................................... 12 Fan-Protection Kit ............................................ 12 Connection Rules Optical-Fibre Cables ........................................ 26 Connections Antenna ........................................................... 24 Connector Flange ............................................ 22 Optical-Fibre Cable.......................................... 26 Power .............................................................. 25 Contact Addresses ................................................. 9 Customer Support Addresses................................. 9 External Inputs Location ........................................................... 22 Flange Connector 5 poles ............................................................. 37 7 poles ............................................................. 37 Grounding............................................................. 23 Illustrations ........................................................... 43 Installation Electrical .......................................................... 20 Mechanical ...................................................... 14 Maintenance......................................................... 39 Mounting Fan Protection ................................................. 19 Pole (Outside).................................................. 17 Wall.................................................................. 16 Optical-Fibre Connection Protective Plug ................................................ 27 Protective-Tube Kit .......................................... 29 Outputs Location ........................................................... 22 Pin Assignment External Alarms ............................................... 37 Replacement of Fan Unit...................................... 40 Spare Parts .......................................................... 45 Specifications Electrical .......................................................... 44 Environmental and Safety................................ 44 Mechanical ...................................................... 44 Troubleshooting.................................................... 38 Page 45
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Raissa Panlilio Comments : Company : Mikom GmbH Create Date : 2011:10:20 10:37:03+02:00 Modify Date : 2011:10:20 10:37:42+02:00 Source Modified : D:20111020081518 Subject : Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 9.4.6 (Windows) Keywords : Creator Tool : Acrobat PDFMaker 9.1 für Word Metadata Date : 2011:10:20 10:37:42+02:00 Format : application/pdf Creator : Raissa Panlilio Title : Additional information on SM2009 Description : Document ID : uuid:66ca4b9d-1b99-4eb4-b6b8-f13776deb960 Instance ID : uuid:e583380f-993f-45ed-a3e3-53fe1ef6670a Page Layout : OneColumn Page Count : 45EXIF Metadata provided by EXIF.tools