Andrew Wireless System U7885L1719P ION-U Remote Unit for cellular systems User Manual User s Manual for ION U LP RU

Andrew Wireless System ION-U Remote Unit for cellular systems User s Manual for ION U LP RU

Contents

user manual

Download: Andrew Wireless System U7885L1719P ION-U Remote Unit for cellular systems User Manual User s Manual for ION U LP RU
Mirror Download [FCC.gov]Andrew Wireless System U7885L1719P ION-U Remote Unit for cellular systems User Manual User s Manual for ION U LP RU
Document ID1935238
Application IDamnwqwj0kIeO2YNR33pv8w==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize226.18kB (2827285 bits)
Date Submitted2013-04-09 00:00:00
Date Available2013-12-26 00:00:00
Creation Date2013-02-28 13:14:44
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2013-02-28 13:14:44
Document TitleUser's Manual for ION-U LP RU
Document CreatorMicrosoft® Word 2010
Document Author: Don Jennings

ION™-U
Optical Remote Unit
ION-U L 7/8/85/17/19
User's Manual
MF0147A0A
DISCLAIMER:
This document has been developed by CommScope, and is intended for the use of its
customers and customer support personnel. The information in this document is subject to
change without notice. While every effort has been made to eliminate errors, CommScope
disclaims liability for any difficulties arising from the interpretation of the information
contained herein. The information contained herein does not claim to cover all details or
variations in equipment, nor to provide for every possible incident to be met in connection
with installation, operation, or maintenance. This document describes the performance of the
product under the defined operational conditions and does not cover the performance under
adverse or disturbed conditions. Should further information be desired, or should particular
problems arise which are not covered sufficiently for the purchaser’s purposes, contact
CommScope.
CommScope reserves the right to change all hardware and software characteristics without
notice.
COPYRIGHT:
© Copyright 2013 CommScope Inc. All Rights Reserved.
This document is protected by copyright. No part of this document may be reproduced,
stored in a retrieval system, or transmitted, in any form or by any means, electronic,
mechanical photocopying, recording, or otherwise without the prior written permission of
CommScope.
TRADEMARKS
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of
CommScope. Names of products mentioned herein are used for identification purposes only
and may be trademarks and / or registered trademarks of their respective companies.
Andrew Wireless Systems GmbH, 04-February-2013
Page 2
User’s Manual for ION-U 7/8/85/17/19
Table of contents
TABLE OF CONTENTS
1. GENERAL
1.1.
USED ABBREVIATIONS
1.2.
HEALTH AND SAFETY WARNINGS
ABOUT COMMSCOPE
11
1.3.
12
INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT
INTRODUCTION
15
1.4.
PURPOSE
15
1.5.
THE ION-U L 7/8/85/17/19 REMOTE UNIT
15
2. FUNCTIONAL DESCRIPTION
17
2.1.
SISO AND MIMO OPERATION
17
2.2.
ION-U 7/8/85/17/19 PORTS
18
3. COMMISSIONING
20
3.1.
3.1.1.
3.1.2.
MECHANICAL INSTALLATION
General
Wall-Mounting Procedure
20
20
21
3.2.
3.2.1.
3.2.2.
3.2.3.
3.2.4.
3.2.5.
3.2.6.
3.2.7.
3.2.8.
3.2.9.
ELECTRICAL INSTALLATION
General
Connections
Grounding (Earthing)
Mains Power Connection
Antenna Connection
Expansion Ports Connections
Alarm Port
Pwr/Ctrl Port
Control Connector RS-232 - Local Interface
24
24
26
28
29
31
32
33
33
34
3.3.
3.3.1.
3.3.2.
OPTICAL-FIBER-CABLE CONNECTION - RULES
Optical cable installation
Commissioning
35
37
39
4. ALARMS
40
4.1.
BITE AND ALARMS
40
4.2.
HANDLING OF ALARMS
40
MF0147A0A
Page 3
Table of contents
4.3.
STATUS LED ALARMS
41
4.4.
EXTERNAL ALARM INPUTS
42
4.5.
TROUBLESHOOTING
43
5. MAINTENANCE
44
5.1.
GENERAL
44
5.2.
RU POWER SUPPLY REPLACEMENT
45
6. APPENDIX
49
6.1.
ILLUSTRATIONS
49
6.2.
ELECTRICAL SPECIFICATIONS
50
6.3.
ENVIRONMENTAL AND SAFETY SPECIFICATIONS
50
6.4.
MECHANICAL SPECIFICATIONS
50
6.5.
SPARE PARTS
51
7. INDEX
Page 4
52
User’s Manual for ION-U 7/8/85/17/19
figures and tables
FIGURES AND TABLES
figure 3-2 Remote unit, SISO.................................................................................... 17
figure 3-3 Remote unit, MIMO Two units paired ....................................................... 17
figure 3-4 RU Connectors and Status LED ............................................................... 18
figure 4-1 Wall-mounting bracket .............................................................................. 21
figure 4-2 RU threaded pins...................................................................................... 21
figure 4-3 RU placed on wall mounting bracket ........................................................ 22
figure 4-4 Install M6x12 screws and washers ........................................................... 22
figure 4-5 Attach M6 nut to threaded pins ................................................................. 23
figure 4-6 Completed SISO RU Mount ..................................................................... 23
figure 4-9 ION-U L 7/8/85/17/19 Connectors ............................................................ 26
figure 4-10 Grounding bolt ........................................................................................ 28
figure 4-11 Grounding bolt, schematic view .............................................................. 28
figure 4-12 AC power cable ...................................................................................... 29
figure 4-13 DC power cable ...................................................................................... 29
figure 4-14 Vdc/100 power cable .............................................................................. 30
figure 4-15 Connect Mains plug ................................................................................ 31
figure 4-16 N-type antenna connection ..................................................................... 32
figure 4-17 Expansion ports ...................................................................................... 33
figure 4-18 Alarm Connector..................................................................................... 33
figure 4-19 Pwr/Ctrl Connector ................................................................................. 34
figure 4-20 RS-232 connector................................................................................... 34
figure 4-21 Remove optics cover .............................................................................. 37
figure 4-22 Remove sealing nut ................................................................................ 37
figure 4-23 Remove split-seal ................................................................................... 37
figure 4-24 Insert fiber optic cables through sealing nut ........................................... 38
figure 4-25 Insert cables through clamp ring............................................................. 38
figure 4-26 Place cables into split-seal ..................................................................... 38
figure 4-27 Press split-seal into opening ................................................................... 39
figure 4-28 Tighten sealing nut ................................................................................. 39
figure 5-1 Alarm triggering ........................................................................................ 40
figure 6-1 Disconnect Mains power .......................................................................... 45
figure 6-2 RU power supply location ......................................................................... 45
figure 6-3 8 RU power supply screws ....................................................................... 46
figure 6-4 RU power supply with cables ................................................................... 46
figure 6-5 RU power supply input cable .................................................................... 46
figure 6-6 RU power supply output cable .................................................................. 47
figure 6-7 Ru with power supply removed ................................................................ 47
figure 6-8 Ru with replacement power supply ........................................................... 47
figure 6-9 Ru insert power supply ............................................................................. 48
figure 6-10 Reconnect Mains power ......................................................................... 48
figure 7-1 Installation drawing ................................................................................... 49
MF0147A0A
Page 5
figures and tables
table 1-1 List of international contact addresses....................................................... 14
table 4-1 Specified torques ....................................................................................... 20
table 4-2: ION-U L 7/8/85/17/19 Connectors ............................................................ 27
table 4-3 AC power cable ......................................................................................... 29
table 4-4 DC power cable ......................................................................................... 29
table 4-5 Vdc/100 power cable ................................................................................. 30
table 4-6 Alarm Connector ........................................................................................ 33
table 4-7 Pwr/Ctrl Connector .................................................................................... 34
table 4-8 RS-232 connector, pin assignment ............................................................ 34
table 5-1 Status LED alarms ..................................................................................... 42
Page 6
User’s Manual for ION-U 7/8/85/17/19
1 General
1. General
1.1. Used Abbreviations
3GPP
AC/DC
AIMOS
ALC
BITE
BTS
CE
CD
CPD
DL
DoC
EDGE
EN
EP
ESD
ETS
EU
GSM
GND
GUI
ICP3
ID No
ION
IP
ISO
LED
LMT
LTE
MIMO
MS
MU
NF
OTRx
PDU
PG
PIM
Pin
Pout
R&TTE
Rev
RF
RU
RX
SNMP
TS
TX
UL
UMTS
UPS
VSWR
WCDMA
WDM
MF0147A0A
rd
3 Generation Partnership Project
Alternating current / Direct Current
Andrew Integrated Management and Operating System
Automatic Level Control
Built-In Test Equipment
Base Transceiver Station
"Conformité Européenne" ("European Conformity")
Compact Disk
Channel Power Detection
Downlink
Declaration of Conformity
Enhanced Data Rates for GSM Evolution
European Norm
Extension Port
Electrostatic Discharge
European Telecommunication Standard
Extension Unit
Global System for Mobile Communication
Ground (Earth)
Graphical User Interface
rd
Intercept Point 3 order
Identification Number
Intelligent Optical Network
Ingress Protection
International Organization for Standardization
Light Emitting Diode
Local Maintenance Terminal
Long Term Evolution
Multiple Input Multiple Output
Mobile Station
Main Unit
Noise Figure
Optical Transceiver = SRMU (Subrack Master Unit)
Power Distribution Unit
Packing Gland
Passive Intermodulation
Input power
Output power
Radio & Telecommunications Terminal Equipment
Revision
Radio Frequency
Remote Unit
Receiver
Simple Network Management Protocol
Technical Specification
Transmitter
Uplink
Universal Mobile Telecommunication System
Uninterruptible Power Supply
Voltage Standing Wave Ratio
Wideband Code Division Multiple Access
Wavelength Division Multiplex
Page 7
1 General
1.2. Health and Safety Warnings
1. Danger: Obey all general and regional installation and safety regulations relating
to work on high voltage installations, as well as regulations covering correct use
of tools and personal protective equipment.
2. Danger: Laser radiation! Do not stare into the beam; do not view it directly or with
optical instruments.
3. Danger: Before opening the unit, disconnect mains power.
4. Danger: Due to power dissipation, the remote unit may reach a very high
temperature. Do not operate this equipment on or close to flammable materials.
Use caution when servicing the unit.
5. Warning: Read and obey all the warning labels attached to the unit. Make sure
that all warning labels are kept in a legible condition. Replace any missing or
damaged labels.
6. Warning: It is the responsibility of the network provider to implement prevention
measures to avoid health hazards associated with radiation from the antenna(s)
connected to the unit.
7. Warning: Make sure, access is restricted to qualified personnel.
8. Warning: Only licence holders for the respective frequency range are allowed to
operate this unit.
9. Warning: Make sure the repeater settings are correct for the intended use (refer
to the manufacturer product information) and regulatory requirements are met.
10. Warning: Use this equipment only for the purpose specified by the manufacturer.
Do not carry out any modifications or fit any spare parts, which are not sold or
recommended by the manufacturer. This could cause fires, electric shock, or
other injuries.
11. Warning: For installations, which have to comply with FCC RF exposure
requirements, the antenna selection and installation must be completed in a way
to ensure compliance with those FCC requirements. Depending on the RF
frequency, rated output power, antenna gain, and the loss between the repeater
and antenna, the minimum distance D to be maintained between the antenna
location and human beings is calculated according to this formula:
D[ cm ] 
P[ mW ]
4    PD[ mW / cm 2 ]
where

Page 8
P (mW) is the radiated power at the antenna, i.e. the max. rated repeater
output power in addition to the antenna gain minus the loss between the
repeater and the antenna.
User’s Manual for ION-U 7/8/85/17/19
1 General

PD (mW/cm²) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B)
for general population / uncontrolled exposures which is
o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz
o 1 for frequencies from 1500MHz to 100.000MHz
RF exposure compliance may need to be addressed at the time of licensing, as
required by the responsible FCC Bureau(s), including antenna co-location
requirements of 1.1307(b)(3).
12. Warning: For installations which have to comply with Europe an EN50385
exposure compliance requirements, the following Power Density limits/guidelines
(mW/cm²) according to ICNIRP are valid:
0.2 for frequencies from 10 MHz to 400 MHz
F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz
1 for frequencies from 2 GHz to 300 GHz
13. Caution: Keep operating instructions within easy reach and make them available
to all users.
14. Caution: Corresponding local particularities and regulations must be observed.
For national deviations, please refer to the respective documents included in the
manual CD that is delivered with the unit.
15. Caution: Although the remote unit is internally protected against overvoltage, it is
strongly recommended to ground (earth) the antenna cables close to the
repeater’s antenna connectors for protection against atmospheric discharge.
16. Caution: ESD precautions must be observed! Before commencing maintenance
work, use the available grounding (earthing) system to connect ESD protection
measures.
17. Note: For a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
18. Note: This unit complies with European standard EN60950.
MF0147A0A
Page 9
1 General
Equipment Symbols Used
Please observe the meanings of the following symbols used in our equipment:
Symbol
Page 10
Compliance
Meaning
---
Alert sign to R&TTE
Symbol
Indicates conformity with the R&TTE
directive 1999/5/EC certified by the notified
body no. 0700.
User’s Manual for ION-U 7/8/85/17/19
1 General
About CommScope
CommScope is the foremost supplier of one-stop, end-to-end radio frequency (RF)
solutions. Part of the CommScope portfolio are complete solutions for wireless
infrastructure from top-of-the-tower base station antennas to cable systems and
cabinets, RF site solutions, signal distribution, and network optimization.
CommScope has global engineering and manufacturing facilities. In addition, it
maintains field engineering offices throughout the world.
Andrew Wireless Systems GmbH based in Buchdorf/ Germany, which is part of
CommScope, is a leading manufacturer of coverage equipment for mobile radio
networks, specializing in high performance, RF and optical repeaters. Our optical
distributed networks and RF repeater systems provide coverage and capacity
solution for wireless networks in both indoor installations and outdoor environments,
e.g. tunnels, subways, in-trains, airport buildings, stadiums, skyscrapers, shopping
malls, hotels and conference rooms.
Andrew Wireless Systems GmbH operates a quality management system in
compliance with the requirements of ISO 9001 and TL 9000. All equipment is
manufactured using highly reliable material. To maintain highest quality of the
products, comprehensive quality monitoring is conducted at all fabrication stages.
Finished products leave the factory only after a thorough final acceptance test,
accompanied by a test certificate guaranteeing optimal operation.
This product meets the requirements of the R&TTE directive and the Declaration of
Conformity (DoC) itself. A current version of the CE DoC is included in this manual
CD delivered *. Any updated version of the DoC is available upon request from the
local sales offices or directly from CommScope via the local Customer Support at
one of the addresses listed in the following chapter.
According to the DoC, our "CE"-marked equipment can be used in all member
states of the European Union.
 Note:
Exceptions of and national deviations from this intended use may be
possible. To observe corresponding local particularities and
regulations, please refer to the respective documents (also in
national language) which are included in the manual CD delivered.
* In case the Declaration of Conformity (DoC) for the product was not included in the manual CD
delivered, it is available upon request from the local sales offices or directly from CommScope at
one of the addresses listed in the following chapter.
To make the most of this product, we recommend you carefully read the instructions
in this manual and commission the system only according to these instructions.
For technical assistance and support, please also contact the local office or
CommScope directly at one of the addresses listed in the following chapter.
MF0147A0A
Page 11
1 General
1.3. International Contact Addresses for Customer Support
Americas:
Canada
United States
CommScope Canada
Andrew LLC, A CommScope Company
Mail
505 Consumers Road, Suite 803
Toronto M2J 4V8
Canada
Mail
620 North Greenfield Parkway
Garner, NC 27529
U.S.A.
Phone
+1-905-878-3457 (Office)
+1-416-721-5058 (Cell)
Phone
+1-888-297-6433
Fax
+1-905-878-3297
Fax
+1-919-329-8950
E-mail
Peter.Masih@commscope.com,
wisupport.us@commscope.com
E-mail
wisupport.us@commscope.com
Caribbean & South American Region
(CALA)
Caribbean (CALA) & Central American Region
CommScope Cabos do Brasil Ltda.
CommScope Mexico S.A. de C.V.
CALA Tech Support for Distributed
Coverage & Capacity Solutions
(DCCS) products:
Mail
Rua Guaporanga, 49
Praça Seca – Rio de Janeiro – RJ
ZIP: 21320-180
Brazil
CALA Tech Support for Distributed
Coverage & Capacity Solutions
(DCCS) products:
Mail
Av. Insurgentes Sur 688, Piso 6
Col. Del Valle, CP: 03100
Mexico City
Mexico
Phone
+1-815-546-7154 (Cell)
+55-15-9104-7722 (Office)
Phone
+52-1-55-5419-5260 (Cell)
+52-55-1346-1900 (Office)
Fax
+ 55-15-2102-4001
Fax
+52-55-1346-1901
E-mail
wisupport@commscope.com
E-mail
wisupport@commscope.com
APAC Countries:
China, India and Rest of Asia
Andrew International Corporation
Australia & New Zealand
Andrew Corporation (Australia) Pty Ltd.
Mail
Room 915, 9/F
Chevalier Commercial Centre
8 Wang Hoi Rd
Kowloon Bay
Hong Kong
Mail
Unit 1
153 Barry Road
Campbellfield
VIC 3061
Australia
Phone
+852-3106-6100
Phone
+613-9300-7969
Fax
+852-2751-7800
Fax
+613-9357-9110
E-mail
wisupport.China@commscope.com
E-mail
wisupport.Australia@commscope.com
Page 12
User’s Manual for ION-U 7/8/85/17/19
1 General
Europe:
United Kingdom
Scandinavia
Andrew Wireless Systems UK Ltd
Andrew Norway (AMNW)
Mail
Unit 15, Ilex Building
Mulberry Business Park
Fishponds Road
Wokingham Berkshire
RG41 2GY
England
Mail
P.O. Box 3066
Osloveien 10
Hoenefoss 3501
Norway
Phone
+44-1189-366-792
Phone
+ 47 32-12-3530
Fax
+44-1189-366-773
Fax
+ 47 32-12-3531
E-mail
wisupport.uk@commscope.com
E-mail
wisupport@commscope.com
Germany
France
Andrew Wireless Systems GmbH
CommScope France
Mail
Industriering 10
86675 Buchdorf
Germany
Mail
Immeuble Le Lavoisier
4, Place des Vosges
92052 Courbevoie
France
Phone
+49-9099-69-0
Phone
+33-1 82 97 04 00
Fax
+49-9099-69-930
Fax
+33-1 47 89 45 25
E-mail
wisupport@commscope.com
E-mail
wisupport@commscope.com
Austria
Switzerland
Andrew Wireless Systems (Austria) GmbH
CommScope Wireless Systems AG
Mail
Weglgasse 10
2320 Wien-Schwechat
Austria
Mail
Tiergartenweg 1
CH-4710 Balsthal
Switzerland
Phone
+43-1706-39-99-10
Phone
+41-62-386-1260
Fax
+43-1706-39-99-9
Fax
+41-62-386-1261
E-mail
wisupport.austria@commscope.com
E-mail
wisupport.ch@commscope.com
Italy
Iberia Region - Spain & Portugal
CommScope Italy S.r.l., Faenza, Italy
Andrew España S.A.
A CommScope Company
Mail
Via Mengolina, 20
48018 Faenza (RA)
Italy
Mail
Avda. de Europa, 4 - 2ª pta.
Parque Empresarial de la Moraleja
Alcobendas, Madrid 28108
Spain
Phone
+39-0546-697111
Phone
+34-91-745-20 40
Fax
+39-0546-682768
Fax
+34-91-661-87 02
E-mail
wisupport.italia@commscope.com
E-mail
wisupport.iberia@commscope.com
MF0147A0A
Page 13
1 General
Czech Republic
CommScope Solutions Czech Republic
C-Com, spol. s r.o
Mail
U Moruší 888
53006 Pardubice
Czech Republic
Phone
+49 871 9659171 (Office)
+49 171 4001166 (Mobile)
Fax
+49 871 9659172
E-mail
wisupport@commscope.com
Africa & Middle East:
Middle East & North Africa
CommScope Solutions International Inc.
(Branch)
South Africa
Andrew Wireless Solutions Africa (PTY)
LTD
11 Commerce Crescent West
Eastgate, Sandton
PO Box 786117
Sandton 2146
South Africa
Mail
PO Box 48 78 22
Unit 3206, Floor 32,
Jumeirah Business Center 5,
Jumeirah Lakes Towers,
Dubai
United Arab Emirates
Mail
Phone
+971 4 390 09 80
Phone
+ 27 11-719-6000
Fax
+971 4 390 86 23
Fax
+ 27 11-444-5393
E-mail
wisupport@commscope.com
E-mail
wisupport@commscope.com
table 1-1 List of international contact addresses
Page 14
User’s Manual for ION-U 7/8/85/17/19
0 Introduction
Introduction
1.4. Purpose
Cellular telephone systems transmit signals in two directions between base
transceiver station (BTS) and mobile stations (MS) within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor
applications, topological conditions or distance from the transmitter, extension of the
transmission range can be achieved by means of an optical distribution system.
Such a system contains an optical Master Unit and several Remote Units. The
number of the Remote Units depends on the hardware and software configuration.
The Remote Units are connected to the Master Unit with optical links.
The Master Unit is the connection to the base transceiver stations. The configuration
of a Master Unit depends on the number of the Remote Units and the frequency
range.
RF signals are transported to the remote units via optical fibers.
1.5. The ION-U L 7/8/85/17/19 Remote Unit
The ION-U 7/8/85/17/19 is a low power remote unit for Cell700, LMR800, Cell850,
AWS, and Extended PCS1900 Band Applications. The unit is compatible with analog,
GSM, EDGE, IS-95, CDMA2000, EVDO, W-CDMA, HSDPA, and LTE modulation
standards. It is used in conjunction with a Master Unit in the ION optical distribution
system. This system transports multiple signals simultaneously, providing a costeffective solution for distributing capacity from one or more base stations.
The ION-U 7/8/85/17/19 transports signals on the RF layer in a very inexpensive
manner. This means that multiple operators and multiple technologies are moved
simultaneously from a cluster of base stations to a remote location over the same
fiber.
The ION optical distribution system is a cost-effective coverage solution for dense
urban areas, tunnels, subway, airports, convention centers, high-rise buildings, and
other locations where physical structures increase path loss. It has been specifically
designed to reduce zoning problems and to provide homogeneous coverage and
capacity.
MF0147A0A
Page 15
0 Introduction
The ION-U L 7/8/85/17/19 is capable of supporting both SISO and MIMO. RF signals
are transported to the remote units via single mode fiber at 1310 nm. MIMO is
achieved with the use of 4 fibers and the pairing of two interlinking RUs.
The system includes an Automatic Gain Control (AGC) that avoids field adjustments
and reduces design, installation, and optimization time.
The ION is easily set-up and supervised via a graphical user interface (GUI). Remote
Units can be commissioned using built-in test equipment. Optical Loss is
compensated through the AGC. Autolevelling allows the output power to be levelled
as specified in the system configuration. The entire system may be monitored
remotely via an Andrew OMC. This platform uses SNMP protocol and is compliant to
X.733 standard.
Should a sophisticated interface not be required, the Master Unit can be directly
connected to the alarm interface of a base station via a LAN (local area network) or
its contact relay.
Features at a glance:

Full band, fully transparent operations

Compatible with Analog, GSM, EDGE, IS-95, CDMA2000, EVDO, W-CDMA,
HSDPA, and LTE modulation standards

5 dB optical budget compensated through AGC

Enhanced communication channel for remote control/setting and SW download

Independent uplink automatic level control (ALC) on each band

1 antenna port

External alarm inputs

Wideband auxiliary channel

Internal swappable power supply adapter

Centralized power supply optionally available
Page 16
User’s Manual for ION-U 7/8/85/17/19
2 Functional Description
2. Functional Description
In the Downlink (DL) path, the remote unit provides:
 Optical to RF conversion of the input optical signal
 Automatic Gain Control (AGC) of each converted signal to compensate for
optical losses
 RF amplification of the converted RF signal for transmission while maintaining
a good signal-to-noise ratio
 RF filtering to reject spurious emissions
In the Uplink (UL) path, the remote unit provides:
 RF amplification to boost the signals received by the antennas to maintain a
good signal-to-noise ratio
 RF filtering to reject spurious emissions
 Automatic Level Control (ALC) to adjust the RF signal level to meet blocking
requirements
 RF-to-optical conversion of the signal, which is convey to the output optical
port
2.1. SISO and MIMO Operation
The modular architecture of the ION-U 7/8/85/17/19 supports both SISO and MIMO
operation. MIMO operation is achieved by pairing two RUs.
The following figures show views of a single ION-U 7/8/85/17/19 remote unit for SISO
applications and two ION-U 7/8/85/17/19 remote units paired for MIMO applications.
figure 2-1 Remote unit, SISO
MF0147A0A
figure 2-2 Remote unit, MIMO Two
units paired
Page 17
2 Functional Description
2.2. ION-U 7/8/85/17/19 Ports
The RF, optical, mains power, alarm, power control, and expansion ports are located
on the bottom of the RU as shown in figure 2-3.
Local Port RS-232
DL optical port
Status LED
UL optical port
Pwr/Ctrl connector
Mains power connector
Alarm connector
RF antenna port
Expansion UL port
Grounding (earthing) bolt
Expansion DL port
figure 2-3 RU Connectors and Status LED
Antenna Port
The RU has one duplex N-female antenna port J for transmitting and receiving
signals to and from distributed antennas. This RF port can be connected directly to
an antenna (i.e. using RF jumper cables) or through splitters, allowing additional
antennas to be fed by the RU.
Status LED
The status LED provides a visual warning of an alarm condition. The color of the LED
indicates the severity of the alarm.
Expansion Ports
The Expansion UL and Expansion DL ports E F are QMA female connectors that
are used to connect to a CommScope expansion unit to provide additional bands.
Page 18
User’s Manual for ION-U 7/8/85/17/19
2 Functional Description
Optical Ports
The LC-APC optical connectors are used to send and receive the signals between
the RU and the Master Unit’s OTRx modules.
 The DL optical port G receives downlink signals from the MU OTRx.
 The UL optical port H transmits uplink signals to the MU OTRx.
Mains Connector
The RU receives its power through the Mains connector I . The type of connector is
dependent on the RU model. A 4-pin Amphenol connector is used for AC models and
standard DC models. A 7-pin Amphenol connector is used for DC models powered
by a duel cable supply.
Pwr/Ctrl Connector
The Pwr/Ctrl connector C supports an optional fan unit. The RU provides power and
fan speed control to the fan unit and receives alarms from it through this 7-pin Binder
connector.
Alarm connector
The RU has two alarm relay inputs that can be used to monitor and report alarms
from external devices. The Alarm connector D is a 5-pin Binder connector.
Local Port RS-232
The RS-232 port A is standard DB-9 female connector used for external modem
communication with an optional extension unit and for local connection to a laptop
PC.
MF0147A0A
Page 19
3 Commissioning
3. Commissioning
3.1. Mechanical Installation
3.1.1. General
Read the health and safety warnings in chapter 1.2.
1. Warning: Do not install the unit in a way or at a place where the
specifications outlined in the Environmental and Safety Specifications
leaflet of the supplier are not met.
2. Warning: It is recommended to use the mounting hardware delivered by the
manufacturer only. If different mounting hardware is used, the
specifications for stationary use of the Remote Unit must not be exceeded.
 Note: Exceeding the specified load limits may cause the loss of warranty!
3. Warning: The unit is considerably heavy. Make sure that a suitable
mounting surface is used. Ensure there is adequate manpower to handle
the weight of the system.
4. Caution: Due to power dissipation, the Remote Unit may reach a very high
temperature. Ensure sufficient airflow for ventilation.
5. Note: When connecting and mounting the cables (RF, optical, mains, ...)
ensure that no water can penetrate into the unit through these cables.
6. Note: Observe all additional rules or restrictions regarding mounting that
apply to specific Remote Unit types.
If any different or additional mounting material is used, ensure that the mounting
remains as safe as the mounting designed by the manufacturer. Ensure that the
static and dynamic strengths are adequate for the environmental conditions of the
site. The mounting itself must not vibrate, swing or move in any way that might cause
damage to the Remote Unit.
Specified torques must be observed for certain mounting procedures according to the
following table:
Type
Thread
Specified torques
Tallow-drop Hex
Spacing
PG
PG
screws
nuts
bolts
(plastic) (aluminium)
M4
M8
M4
M8
PG 13.5 PG 29
3.3 Nm
27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm
table 3-1 Specified torques
Page 20
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
3.1.2. Wall-Mounting Procedure
1. Check the suitability of the
wall-mounting kit and the wall.
2. Install
the
wall-mounting
bracket using 4 M6 screw
anchors
(not
included*)
according to the drilling layout.
Confirm that the bracket is
securely fastened to the wall.
* The M6 screw anchors are
not included as part of the RU
delivery because the suitable
type depends on the on-site
conditions (wall structure and
materials). Therefore, use
screw anchors that are
appropriate for the mounting
surface.
figure 3-1 Wall-mounting bracket
3. Attach the M6 threaded pins to
the Remote Unit (on the both
sides).
figure 3-2 RU threaded pins
MF0147A0A
Page 21
3 Commissioning
4. Install the Remote Unit on the
wall-mounting
bracket
by
lifting the RU into place and
lowering it down onto the
bracket. The M6 pins must
align with the slots in the
bracket to support the RU.
B0303A8A
figure 3-3 RU placed on wall mounting bracket
5. Fasten the lower section of the
Remote Unit to the bracket
using a washer and a M6x12
screw (on both sides). Slide a
washer over each screw and
then insert the screw and
tighten it securely.
Washer
M6x12 screw
B0303A9A
figure 3-4 Install M6x12 screws and washers
Page 22
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
6. Fasten the Remote Unit to the
bracket using a washer and
M6 nut. Slide the washer over
the threaded pins that were
installed in step 3 and then
screw the nut onto the pins
(on both sides) and tighten
securely.
M6 nut
Washer
B0303AAA
figure 3-5 Attach M6 nut to threaded pins
7. Confirm that all screws and
nuts have been fastened and
the unit is securely mounted to
the wall.
figure 3-6 Completed SISO RU Mount
MIMO mounting instructions
MF0147A0A
Page 23
3 Commissioning
3.2. Electrical Installation
3.2.1. General
Read the health and safety warnings in chapter 1.2.
1. Warning: This unit contains dangerous voltages. Loss of life, severe personal
injury, or property damage can be the result if the instructions contained in this
manual are not followed.
2. Caution: It is compulsory to ground (earth) the unit before connecting the power
supply. A grounding bolt is provided on the cabinet to connect the ground-bonding
cable.
3. Caution: Although the remote unit is internally protected against overvoltage, it is
strongly recommended to ground (earth) the antenna cables close to the antenna
connectors of the remote unit for protection against atmospheric discharge. In
areas with strong lightning, it is strongly recommended to install additional
lightning protection.
4. Caution: If the mains connector of the remote unit is not easily accessible, a
disconnect device in the mains power circuit must be provided within easy reach.
5. Caution: Before connecting or disconnecting the mains connector at the remote
unit, ensure that mains power supply is disconnected.
6. Caution: Make sure that an appropriate circuit breaker acting as a disconnect
device (as required by IEC/EN60950-1) and an overcurrent limiting device are
connected between mains power and the Remote Unit.
7. Caution: A connection of the mains supply to a power socket requires the power
socket to be nearby the remote unit.
8. Caution: Incorrectly wired connections can destroy electrical and electronic
components.
9. Caution: To avoid corrosion at the connectors caused by electrochemical
processes, the material of the cable connectors must not cause a higher potential
difference than 0.6 V (see electrochemical contact series).
10. Note: Use an appropriate torque wrench for the coupling torque of N-type
connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna
connectors. For example, use torque wrench of item no. 244379 available from
the CommScope e-catalog. Do NOT use your hands or any other tool (e.g. a pair
of pliers)! This might cause damage to the connector and lead to a malfunction of
the Remote Unit.
Page 24
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
11. Caution: For unstabilized electric networks, which frequently generate spikes, the
use of a voltage limiting device is advised.
12. Caution: The unit complies with the surge requirement according to EN 61000-45 (fine protection); however, installation of an additional medium (via local supply
connection) and/or coarse protection (external surge protection) is recommended
depending on the individual application in order to avoid damage caused by
overcurrent.
13. Caution: Observe the labels on the front panels before connecting or
disconnecting any cables.
MF0147A0A
Page 25
3 Commissioning
3.2.2. Connections
The ION-U RU ports and connectors shown below are located at the base of the RU.
figure 3-7 ION-U L 7/8/85/17/19 Connectors
Port/Conn
LOCAL
RS-232
STATUS
PWR/CTRL
ALARM
EXPANSION
UL
Page 26
ION-U L 7/8/85/17/19 Connectors/Indicators
Purpose
This connector is used for external modem
communication with an optional extension unit
and for local connection to a laptop PC.
This LED provides a visual warning of an alarm
condition. The color of the LED indicates the
severity of the alarm.
This connector supports an optional fan unit. The
RU provides power and fan speed control to the
fan unit and receives alarms from it.
This connector provides alarm contacts that are
used to monitor and report alarms generated by
other equipment.
This connector is used to connect to the UL port
of an expansion unit to provide additional bands
of coverage
Type
DB-9 Female
LED
Binder 712
series 7-pin
Binder 712
series 5-pin
QMA Female
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
Port/Conn
EXPANSION
DL
ION-U L 7/8/85/17/19 Connectors/Indicators
Purpose
This connector is used to connect to the DL port
of an expansion unit to provide additional bands
of coverage
OPTICS UL
This connector is used to connect an optical fiber
cable to send uplink signal back to the OTRx
module of the ION-U master unit
OPTICS DL
This connector is used to connect an optical fiber
cable to receive downlink signal from the OTRx
module of the ION-U master unit
MAINS
This connector provides the power to RU models
(Vac/Vdc)
that use standard AC (85 to 265 Vac) or RU
models that use standard DC (-60 to -38 Vdc)
power.
MAINS
This connector provides the power to RU models
(Vdc/100)
used in locations where the power drawn on
each cable must be limited to a maximum of 100
VA.
Grounding Bolt Ground (earth) bolt for connecting the mandatory
ground cable to the RU
ANT RF
This connector is used for transmitting and
receiving signals to and from an antenna or
antenna splitter.
Type
QMA Female
LC-APC
LC-APC
Amphenol C016
Series, 4-Pin
Amphenol C016
Series, 7-Pin
M8 bolt, hex
nut, & washers
N-type female
table 3-2: ION-U L 7/8/85/17/19 Connectors
MF0147A0A
Page 27
3 Commissioning
3.2.3. Grounding (Earthing)
The RU must be grounded (earthed).
1. Connect an earth-bonding cable to the grounding bolt connection provided on the
outside of the remote unit (near the Mains connector) as shown in figure 3-8. Do
not use the grounding connection to connect external devices.
figure 3-8 Grounding bolt
figure 3-9 Grounding bolt, schematic view
2. After loosening the hex nut, connect the earth-bonding cable between the two
washers as illustrated in the figures above.
3. Then, fasten all parts again by tightening the the hex nut.
4. Connect the other end of the ground wire to a suitable permanent ground
following local electrical code practices.
Page 28
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
3.2.4. Mains Power Connection
Before connecting electrical power to the units, the system must be grounded
(earthed) as described in the previous chapter.
The Mains power must be connected to the Mains connector of the unit for operation
of the RU. A power cable is delivered with each RU. The type of power cable
delivered is dependent on the type of power supply in the RU.
The AC power cable is a 3.2 m (10.5 ft) 16 AWG cable with a 4-pin Amphenol C016
series plug on one end to connect to the RU Mains connector. The other end of the
cable is un-terminated with 3 end splices to connect to the AC power source. A 10 m
(33.7 ft) AC power cable (part no. 7573605-00) is also available as an option. The AC
power cable is shown in figure 3-10.
Protective Cap
Amphenol 4-Pin
female connector
3x end splice
blue
brown
yellow / green
RU Mains
Connector
B0302ASA
figure 3-10 AC power cable
4-Pin Amphenol C016
Series
Pin Name
Color
Phase
Brown
Neutral
Blue
n.c.
n.c
Ground Yellow /
Green
table 3-3 AC power cable
The standard DC power cable is a 3.2 m (10.5 ft) 13 AWG cable with a 4-pin
Amphenol C016 series plug on one end to connect to the RU Mains connector. The
other end of the cable is un-terminated with 2 end splices to connect to the -48 Vdc
power source. The standard DC power cable is shown in figure 3-11.
Protective Cap
Amphenol 4-Pin
female connector
2x end splice
black
red
RU Mains
Connector
figure 3-11 DC power cable
MF0147A0A
4-Pin Amphenol C016
Series
Pin Name
Color
n.c
n.c
–48V
Black
0V
Red
n.c.
n.c
B0302ATA
table 3-4 DC power cable
Page 29
3 Commissioning
The Vdc/100 power cable is available for locations where the power drawn on each
cable must be limited to a maximum of 100 VA. This cable is a 3.2 m (10.5 ft) 16
AWG cable with a 7-pin Amphenol C016 series plug on one end to connect to the RU
Mains connector. The other end of the cable is un-terminated with 4 end splices to
connect to the -48 vdc power source.
Protective Cap
Amphenol 7-Pin
female connector
4x end splice
RU Mains
Connector
B0302AUA
figure 3-12 Vdc/100 power cable
7-Pin Amphenol C016
Series
Pin Name
Color
0V
–48V
n.c.
0V
–48V
n.c
Ground
table 3-5 Vdc/100 power
cable
For the AC power supply connection, a minimum cross section of 1.5
mm2 is required and for the DC power supply connection, a minimum
cross section of 2.5 mm2 is required. Each wire must observe the
applicable national regulations regarding loop impedance, voltage drop,
and methods of installation. Make sure to connect the correct voltage to
the unit.
 Note:
Do not connect or disconnect the power cable at the mains
connector while power is on. Turn off mains* power before
connecting the power cable at the remote unit, then, engage mains
power again.
* Mains power must be interruptible with an external mains breaker. For the
mains breaker, observe the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC
service is needed, i.e. the external AC breaker should be 20 Amps max. for
120-Volt service or 16 Amps for 240-Volt service.
For the DC power supply, observe the local regulations of the DC service
provider.
Use the following method to install and connect the Mains power to the RU:
1. Locate the Mains power cable that was delivered with the RU.
2. Locate or install a suitable power junction box or receptacle near the RU and
route the power cable from the power source to the RU. Do not connect the
cable to the RU’s Mains connector at this time. The power source must be
interruptible.
Page 30
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
3. The Mains cable must be properly secured observing local regulations and
electrical codes. Be sure to allow enough slack in the cable at the RU to plug
or unplug the cable into the Mains connector of the RU.
4. Wire the power cable to the junction box or receptacle. Refer to the color code
and pin numbers shown in figure 3-10 (AC cable), figure 3-11 (DC cable), or
figure 3-12 (Vdc/100 cable) depending on the type of power supply used by
the RU.
5. With the cable’s Mains plug disconnected from the RU, turn the circuit breaker
on, unscrew the plug’s protective cover, and carefully test the plug with a
voltmeter to ensure that the voltage and polarity are correct.
6. Once the testing has been completed, turn off the circuit breaker.
7. Unscrew the protective cover from the Mains connector of the RU.
8. Insert the plug into the Mains connector (figure 3-13) and tighten the clamping
ring until it is hand tight. Do not over-tighten the clamping ring.
Mains
connector
Clamping ring
Mains plug
figure 3-13 Connect Mains plug
3.2.5. Antenna Connection
The Remote Unit has one N-type antenna connector (figure 3-14). For mounting the
cable connector, it is recommended to refer to the corresponding documentation of
the connector manufacturer. The bending radius of the antenna cables must remain
within the given specifications.
MF0147A0A
Page 31
3 Commissioning
The selection of cable and antenna is an important consideration. On the one hand, a
cable with higher loss is less expensive but, on the other hand, it impairs
performance.
Use an appropriate torque wrench for the coupling torque of N-type
connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type
antenna connectors. For example, use torque wrench of item no. 244379
available from the CommScope e-catalog. Do NOT use your hands or any
other tool (e.g. a pair of pliers)! This might cause damage to the
connector and lead to a malfunction of the Remote Unit.
To minimize passive inter-modulation (PIM) distortion, attention must be
paid to the physical condition of the connector junctions. Do not use
connectors that show signs of corrosion on the metal surface. Prevent
the ingress of water into the connector. Attach and torque the
connectors properly.
1. Route the antenna cable from the antenna or splitter to the base of the RU.
2. Cut the cable to length and terminate the cable with an N-type male connector.
3. Remove the red plastic protective cover from the N-type female connector.
4. Using an appropriate torque wrench, connect the cable to the antenna port of
the RU.
N-type antenna connector
Antenna cable
figure 3-14 N-type antenna connection
3.2.6. Expansion Ports Connections
The Expansion ports are QMA-F connectors that are used to connect to an
expansion unit to provide additional bands of coverage.
Page 32
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
1. Connect an RF cable with QMA male connectors between the UL Expansion
port connector of the RU to the UL port of the expansion unit. Press the QMA
connector of the cable onto the UL port of the RU until it clicks into place to
connect the cable.
2. Connect an RF cable with QMA male connectors between the DL Expansion
port connector of the RU to the DL port of the expansion unit. Press the QMA
connector of the cable onto the DL port of the RU until it clicks into place to
connect the cable.
UL
To Expansion unit
DL
figure 3-15 Expansion ports
3.2.7. Alarm Port
The Alarm port provides alarm contacts that are used to monitor and report alarms
generated by other equipment. The connector is a 5-pin Binder 712 series connector.
B303ALA
figure 3-16 Alarm Connector
5-Pin Binder 712
Series
Pin
Assignment
EXT1_Alarm
EXT1_GND
n.c.
EXT2_Alarm
EXT_GND
table 3-6 Alarm
Connector
3.2.8. Pwr/Ctrl Port
The Pwr/Ctrl port is used to handle an optional fan unit. The connector will provide
power to the fan unit and will allow the RU to control the fan speed. The connector is
a 7-pin Binder 712 series connector.
MF0147A0A
Page 33
3 Commissioning
7-Pin Binder 712
Series
Pin
Assignment
+V_FAN
Fan1 Alarm In
Fan1 (PWM) Out
GND_FAN
Fan2 Alarm In
Fan2 (PWM) Out
n.c
B303AMA
table 3-7 Pwr/Ctrl
Connector
figure 3-17 Pwr/Ctrl Connector
3.2.9. Control Connector RS-232 - Local Interface
This DB-9 female connector is used for external modem communication with a
possible extension unit and for local connection with a laptop.
B303APA
figure 3-18 RS-232 connector
Page 34
PIN
DB-9 Female
Assignment
Not connected (n.c.)
RS232 Rx
RS232 Tx
n.c.
GND (RS232)
n.c.
n.c.
n.c.
table 3-8 RS-232 connector, pin assignment
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
3.3. Optical-Fiber-Cable Connection - Rules
Main optical system parameters:
Fiber:
 Single mode fiber, type is 9.5/125 µm
 Fiber-cable connectors LC/APC
ION-U system:
 The pigtails for the connection between Master Unit and Remote Unit must
have a sufficient length. Protection for the optical fibers must be provided
where the fibers feed into the units.
 The system attenuation of the optical fibers, including the connectors, must
not exceed 5 dB.
System attenuation and attenuation of optical components must be determined. This
can be achieved by measuring attenuation and reflection with an appropriate
measuring instrument. For pigtails, a total value of < 0.4 dB (measured to a reference
plug) can be assumed due to the dead zone of the reflectometer. These
measurements must be made with a sufficient length of optical fiber, at the input and
output of the device which has to be measured.
Fiber-System Installation:
Fiber-cable connectors have to be of the same type (LC/APC) as the connectors
used for the unit. The fiber-optic cables are connected to the optical transceiver.
Angled connectors are not compatible with straight optical connectors;
non-compatibility of connectors will result in permanent damage to
both connectors.
Before connecting the fiber cables, follow the procedure below to ensure optimized
performance. It is important for these procedures to be carried out with care:

Remove fiber-optic protective caps just before making the fiber connections.
Do not leave any LC/APC connectors open as they may attract dirt. Unused
optical connectors must always be covered by their caps.

Do not bend the fiber-optic cable in a tight radius (< 5 cm) as this may cause
damage to the cable and interrupt transmission.

Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of
the fiber-optic cable that will be inserted in the optical connectors on the donor
interface box. Use a fiber end-face inspection tool to scan both, the class fiber
and its surrounding area.

Check for dirt on the cladding, chips/pits, dirt on the ferrule, and scratches.
MF0147A0A
Page 35
3 Commissioning

Connect the fiber-optic cables by inserting the cable end into the laser
receptacle.

Do not use any index-matching gels or fluids of any kind in these connectors.
Gels are intended for laboratory use and attract dirt in the field.
 Note:
Care should be taken when connecting and disconnecting fiberoptic cables - use the connector housing to plug or unplug a fiber.
Scratches and dust significantly affect system performance and
may permanently damage the connector. Always use protective
caps on fiber-optic connectors not in use.
Cleaning Procedure for Fiber-Optical Components:
Any contamination in the fiber connection results in additional optical transmission
loss which could cause whole system failure. It is thus recommended that every fiber
connector be inspected and cleaned prior to mating.
The goal is to eliminate any dust or contamination and to provide a clean
environment for the fiber-optic connection.
When you clean fiber components, always complete the following steps carefully:
1. Turn off the ION-U system (laser sources) before you inspect fiber connectors.
Never look into a fiber while the system lasers are on!
2. Check the connectors or adapters with a fiberscope before cleaning.
3. If the connector is dirty, clean it with a lint-free wipe (dry cleaning).
4. Inspect the connector.
5. If the connector is still dirty, repeat the dry cleaning technique.
6. Inspect the connector.
7. If the connector is still dirty, clean it with 99% isopropyl alcohol (wet cleaning)
followed immediately with a dry clean in order to ensure no residue is left on
the endface.
8. Repeat steps 5 through 7 until endface is clean.
Note: For a more detailed description, please refer to:
http://www.cisco.com/en/US/tech/tk482/tk876/technologies_white_paper09186
a0080254eba.shtml
Page 36
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
3.3.1. Optical cable installation
1. Locate the Optics connector cover on the lower right side of the RU. Loosen
the four cover screws, remove the cover, and set it aside. Removing this cover
allows access to the UP and DL optical connectors.
Optical
Connectors
Cover
Screws
figure 3-19 Remove optics cover
2. Remove the sealing nut from the optical cable gland at the bottom of the RU.
Sealing
nut
figure 3-20 Remove sealing nut
3. Remove the split-seal by pulling it downward and out of the clamp ring.
Cable gland
clamp ring
Cable gland clamp
ring with split seal
removed
Split-seal
figure 3-21 Remove split-seal
4. Insert the UL and DL optical cables through the sealing nut as shown in figure
3-22.
MF0147A0A
Page 37
3 Commissioning
Sealing
nut
figure 3-22 Insert fiber optic cables through sealing nut
5. Then insert the optical cables through the opening in the cable gland clamp
ring
6. Connect the optical cables to the proper UL and DL LC/APC connectors.
Connect
LC/APC Optical
Cables
Clamp
ring
figure 3-23 Insert cables through clamp ring
7. Separate the two halves of the split-seal. Place each cable into one of the
grooves in the lower half of the split-seal. Place the other half of the split-seal
over the fiber optic cables.
Split-seal
Split-seal
Split-seal
grooves
figure 3-24 Place cables into split-seal
Page 38
User’s Manual for ION-U 7/8/85/17/19
3 Commissioning
8. Press the split-seal up into the clamp ring opening.
Split-seal
Sealing
nut
figure 3-25 Press split-seal into opening
9. Tighten the sealing nut securely.
Sealing
nut
figure 3-26 Tighten sealing nut
10. Replace the optics metal cover and tighten the four screws that were
loosened in step 1.
3.3.2.
Commissioning
Read the health and safety warnings in chapter 3.3.2 Commissioning as well as the
description carefully to avoid mistakes and proceed step-by-step as described!

Do not operate the remote unit without terminating the antenna connectors.
The antenna connectors may be terminated by connecting them to their
respective antennas or to a dummy load.

Only qualified personnel should carry out the electrical, mechanical,
commissioning, and maintenance activities that require the unit to be powered
on when open.

When opening the remote unit do not damage the warranty labels on the
internal devices. The warranty is void if the seals are broken.

Ensure that all connections have been performed according to chapter 3.2.2
Connections.
MF0147A0A
Page 39
4 Alarms
4. Alarms
4.1. Bite and Alarms
The Built-In Test concept comprises the monitoring of the power supplies, the power
amplifiers, and the optical interface.
All alarms that occur can be checked via software at the master unit.
4.2. Handling of Alarms
As soon as the software acknowledges a valid alarm, a message is transmitted to the
master unit.
If the reason for the alarm has been cleared or if the alarm should continue, a new
alarm message will not be repeated. If there is an interruption of at least five seconds
after acknowledgement, a new alarm message will be generated.
<5s
>5s
>5s
Alarm cause
raise
clear
raise
clear
Alarm transmit
Alarm LED
V1651A2
figure 4-1 Alarm triggering
Page 40
User’s Manual for ION-U 7/8/85/17/19
4 Alarms
4.3. Status LED Alarms
For local supervision, a status LED on the connector panel of the remote unit
adjacent to the Expansion ports provides a visual warning of an alarm condition. The
color of the LED indicates the severity of the alarm. Detailed alarm information is
available through the ION-U software interface. This table lists the alarm conditions
and possible on-site measures that could be performed to resolve the issues
responsible for triggering the alarms.
Alarm Name
Description
Fan Failure
DL optical power fail
Temperature Alarm
VSWR Alarm
RF Low Output
CELL700
RF Low Output CELL
850
RF Low Output LMR
800
RF Low Output PCS
1900E
RF Low Output AWS
Received optical power
below minimum threshold
temperature too high
bad RF cabling /
mismatched antenna
RF signal too low
RF signal too low
RF signal too low
RF signal too low
RF signal too low
Remedy
check ventilation and environment
check fiber connections and
transmitted optical power
check ventilation and environment
check cable / antenna
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
Default
Severity
LED
critical
Red
major
Red
warning
Green
critical
Yellow
minor
Green
minor
Green
minor
Green
minor
Green
minor
Green
DL CELL 700 band
alarm
hw failure in RF section
change unit
critical
Red
DL LMR800+CELL850
alarm
hw failure in RF section
change unit
critical
Red
DL PCS 1900E band
alarm
hw failure in RF section
change unit
critical
Red
DL AWS band alarm
hw failure in RF section
change unit
critical
Red
hw failure in RF section
change unit
critical
Red
hw failure in RF section
change unit
critical
Red
hw failure in RF section
change unit
critical
Red
hw failure on RF section
too high RF signal feeding
device
change unit
critical
Red
check unit/attenuator configuration
minor
Green
check unit/attenuator configuration
minor
Green
check unit/attenuator configuration
minor
Green
check unit/attenuator configuration
minor
Green
change unit
critical
Red
change unit
major
Red
check external device/ check alarm
connection
major
Yellow
UL CELL 700 band
alarm
UL LMR800+CELL850
band alarm
UL PCS 1900E band
alarm
UL AWS band alarm
UL Overdrive/ALC
Limiting CELL 700
UL Overdrive/ALC
Limiting
LMR800+CELL850
UL Overdrive/ALC
Limiting PCS 1900E
UL Overdrive/ALC
Limiting AWS
Internal bus alarm
UL Laser Alarm
External 1 Alarm
MF0147A0A
too high RF signal feeding
device
RF signal feeding device
too high
RF signal feeding device
too high
internal I2CBUS
communication malfunction
Uplink laser fail (cooling or
current failure)
external input alarm
Page 41
4 Alarms
Alarm Name
External 2 Alarm
RF High Output
CELL700
RF High Output CELL
850
RF High Output LMR
800
RF High Output PCS
1900E
RF High Output AWS
Power Supply 1 Alarm
Power Supply 2 Alarm
Power Supply 1
exceeded load
threshold
Power Supply 2
exceeded load
threshold
Power Supply 1 partial
availability
Power Supply 2 partial
availability
High Power
Consumption
Low Power
Consumption
Default
Severity
LED
major
Yellow
major
Green
major
Green
major
Green
major
Green
major
Green
change/verify unit
major
Red
change/verify unit
major
Red
power supply load too high
change/verify unit
minor
Green
power supply load too high
change/verify unit
minor
Green
change/verify unit
major
Green
change/verify unit
major
Green
power supply load too high
change/verify unit
minor
Green
power supply load too low
change/verify unit
minor
Green
Description
external input alarm
RF signal too high
RF signal too high
RF signal too high
RF signal too high
RF signal too high
internal power supply
alarm
internal power supply
alarm
internal power supply
alarm / partial power
available
internal power supply
alarm / partial power
available
Remedy
check external device/ check alarm
connection
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
check BTS output level/attenuator
configuration/RF cabling
table 4-1 Status LED alarms
4.4. External Alarm Inputs
With the external alarm inputs, it is possible to monitor the status of connected
devices, e.g. a UPS, via software. All alarm inputs are normally high (5 V) without
connection. The polarity (high/ low) can be set via the software at the Master Unit (for
details please see the appropriate ION-U software manual).
The device to be monitored must be connected so that the alarm contacts will be
closed in case of an alarm (I max = 8 mA). The alarm inputs are potential-free with
common ground (earth).
Subminiature circular connectors series 712 with five contacts, which are contained
in the alarm kit, can be ordered directly from the Binder Connector Group, the
manufacturer, or indirectly from CommScope. For the designation of the alarm kit see
chapter 6.5 Spare Parts.
Page 42
User’s Manual for ION-U 7/8/85/17/19
4 Alarms
4.5. Troubleshooting
The status of the remote unit can be checked via the master unit (for details please
refer to the ION-U software manual). Locally, the status can be checked at the LED,
see chapter 4.3 Status LED Alarms.
MF0147A0A
Page 43
5 Maintenance
5. Maintenance
5.1. General
Read the health and safety warnings in chapter 1.2.
 Note:
The remote unit does not require preventative maintenance
measures.
Maintenance of the ION-U L 7/8/85/17/19 should be performed by replacing only
components that are described in this chapter. In order to maintain the warranty,
avoid unintentional damage to the seals on the modules.
The spare parts list, includes only units that can be replaced in the field without
tuning or soldering work.
 Note:
When sending back the unit, use appropriate packaging. Use of
the original packaging for shipping the unit is strongly
recommended!
 Note:
Defective parts should only be replaced by original parts from the
supplier. All service work performed inside the housing is
performed at the users own risk.
 Note:
Ensure the Remote Unit has been disconnected from mains power
during maintenance.
 Note:
Label any unlabelled cables before disconnecting them to ensure
correct reconnection.
For most maintenance procedures, appropriate tools are required to ensure correct
handling. All of these tools can be ordered from the supplier.
 Note:
All Remote Unit screws have a right-hand thread, and are
tightened by turning the screws clockwise and loosened by
turning them counter-clockwise with an appropriate tool.
Due to the design of the remote unit, the power supply is the only component that
should be replaced in the field. Please contact the supplier for replacement of any
other components.
Page 44
User’s Manual for ION-U 7/8/85/17/19
5 Maintenance
5.2. RU Power Supply Replacement
The power supply for the RU is a field replaceable module. The type of power supply
used by the RU (AC, DC, or Vdc/100) is dependent on the model number of the RU.
Before starting any maintenance on the RU, read the health and safety
warnings in chapter 1.2 and the electrical installation general information
in chapter 4.2.1.
1. Switch off the circuit breaker
supplying power to the RU.
2. Once you have confirmed that
the power has been shutdown,
remove
Mains
power
connector from the RU.
Mains plug
figure 5-1 Disconnect Mains power
3. Locate the power supply on
the right side of the Remote
Unit.
Power
supply
figure 5-2 RU power supply location
MF0147A0A
Page 45
5 Maintenance
4. Use a #2 Phillips head or
slotted screwdriver to loosen
the 8 universal slot/Phillips
captive power supply screws
and carefully remove the
supply. The weight of the
power
supply
must
be
supported as you loosen the
screws to prevent damage to
the supply.
Loosen 8 universal
slot/Phillips screws
Mains
connector
figure 5-3 8 RU power supply screws
5. Carefully remove the power
supply from the unit. Do not
attempt to support the weight
of the supply with the attached
input and output cables.
figure 5-4 RU power supply with cables
6. Locate
the
input
cable
connector for the power
supply on the right side of the
supply.
7. Loosen the 3 Phillips head
terminal screws and remove
the connector.
figure 5-5 RU power supply input cable
Page 46
User’s Manual for ION-U 7/8/85/17/19
5 Maintenance
8. Locate the output connector
for the power supply on the
left side of the supply.
9. Loosen the 2 Phillips head
screws and remove the output
connector.
figure 5-6 RU power supply output cable
10. Remove the defective supply.
figure 5-7 Ru with power supply removed
11. Replace the defective power
supply with the new power
supply.
It is very important to confirm
that the replacement supply is
the same type as the original
supply. The AC, DC, and
Vdc/100 supplies are not
interchangeable.
12. Reconnect the input and
output connectors, and tighten
the
associated
terminal
screws.
MF0147A0A
figure 5-8 Ru with replacement power supply
Page 47
5 Maintenance
13. Insert the power supply into
the RU carefully to avoid
damaging any cables. The
supply must be supported until
the 8 universal slot/Phillips
captive power supply screws
have been tightened.
14. Tighten the 8 universal
slot/Phillips captive power
supply screws.
figure 5-9 Ru insert power supply
15. Reconnect the Mains power
plug.
16. Switch on the breaker and
check the RU for proper
operation.
figure 5-10 Reconnect Mains power
Page 48
User’s Manual for ION-U 7/8/85/17/19
6 Appendix
6. Appendix
6.1. Illustrations
Need drawings with dimensions here
figure 6-1 Installation drawing
MF0147A0A
Page 49
6 Appendix
6.2. Electrical Specifications
Please refer to the “ION-U_LP_RU_US_PA-106156-EN.GB.pdf” data sheet for the
Remote Unit’s electrical specifications.
6.3. Environmental and Safety Specifications
Please refer to the “ION-U_LP_RU_US_PA-106156-EN.GB.pdf” data sheet for the
Remote Unit’s environmental and safety specifications.
6.4. Mechanical Specifications
Please refer to the “ION-U_LP_RU_US_PA-106156-EN.GB.pdf” data sheet for the
Remote Unit’s mechanical specifications.
Page 50
User’s Manual for ION-U 7/8/85/17/19
7 Index
6.5. Spare Parts
The following table lists the spare parts available for the Remote Unit. The
configuration of the delivered unit meets the requirements of the customer and can
differ depending on the state of the delivery.
Maintenance of the ION-U L 7/8/85/17/19 should be performed on an FRU (Field
Replaceable Unit) basis only. Do not damage the warranty labels on the
components, as this voids the warranty.
If a FRU which is not included in the following list needs to be replaced, please
contact customer service for additional instructions.
ION-U L 7/8/85/17/19 Spare Parts List
Designation:
Need Spare Parts
ID No:
Need ID Numbers
Accessories
Need Accessories and part numbers
The manufacturer reserves the right to replace the spare parts listed above by
equivalent substitutes!
 Note: Only the spare parts listed above are FRUs (= Field Replaceable
Units) and can be replaced by the user. For replacement of any other
parts, please send the entire Remote Unit back to the manufacturer.
MF0147A0A
Page 51
7 Index
7. Index
Abbreviations .......................................................... 7
ALARM ................................................................. 27
Alarm connector ................................................... 20
Alarm port ....................................................... 27, 34
Alarms
Bite and Alarms ............................................... 41
External Inputs ................................................. 43
Handling of Alarms .......................................... 41
Status LED....................................................... 42
Amphenol C016 series plug.................................. 30
ANT RF ................................................................ 28
Antenna Port ....................................................... 19
Health and Safety Warnings ................................... 8
MAINS (Vac/Vdc) ................................................. 28
MAINS (Vdc/100) ................................................. 28
Mains connector ............................................. 20, 30
Maintenance ......................................................... 45
MIMO applications ................................................ 18
Mounting
Wall.................................................................. 22
Block Diagram
ION-U L 7/8/85/9/17/19 RU.............................. 17
CE Declaration of Conformity (DoC)..................... 11
Commissioning
General ............................................................ 40
CommScope ......................................................... 11
Connection Rules
Optical-Fiber Cables ........................................ 36
Connections
Antenna ..................................................... 32, 33
Connector Panel .............................................. 27
Power .............................................................. 30
Contact Addresses
Customer Support................................ 12, 13, 14
Customer Support Addresses................... 12, 13, 14
Declaration of Conformity (DoC)........................... 11
EXPANSION DL ................................................... 28
Expansion ports .................................................... 33
Expansion Ports ................................................. 19
EXPANSION UL ................................................... 27
Illustrations ........................................................... 50
Installation
Electrical .......................................................... 25
Mechanical ...................................................... 21
ION-U 7/8/85/9/17/19 ........................................... 15
ION-U 7/8/85/9/17/19 RU Ports ............................ 19
Optical cable installation ....................................... 38
Optical Ports ....................................................... 20
OPTICS UL .......................................................... 28
PWR/CTRL ........................................................... 27
Pwr/Ctrl connector .......................................... 20, 27
RS-232 ................................................................. 27
RS-232 port .......................................................... 20
RU AC power cable .............................................. 30
RU DC power cable .............................................. 30
RU Power Supply Replacement ........................... 46
RU Vdc/100 power cable ...................................... 31
Fiber-Optical Components
Cleaning Procedure ......................................... 37
System Installation ........................................... 36
SISO applications ................................................. 18
Spare Parts .......................................................... 52
Specifications
Electrical .......................................................... 51
Environmental and Safety................................ 51
Mechanical ...................................................... 51
Status ................................................................... 27
Grounding (Earthing) ............................................ 29
Grounding Bolt...................................................... 28
Troubleshooting .................................................... 44
Page 52
User’s Manual for ION-U 7/8/85/17/19


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 53
Language                        : de-DE
Tagged PDF                      : Yes
Title                           : User's Manual for ION-U LP RU
Author                          : Don Jennings
Keywords                        : M0147A0A
Creator                         : Microsoft® Word 2010
Create Date                     : 2013:02:28 13:14:44+01:00
Modify Date                     : 2013:02:28 13:14:44+01:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XS5-U7885L1719P

Navigation menu