Autec s r l LKNDA1DM Transceiver unit User Manual 2
Autec s.r.l. Transceiver unit 2
Contents
User Manual 2
Original instructions Air series Part B: Conformity and frequencies (434 and 915MHz) Index Conformity .............................................................................................................. 1.1 Conformity of frequency band 433.050-434.790MHz ......................................... 1.2 Conformity of frequency band 915-928MHz: FCC and IC .................................. Frequencies ............................................................................................................ 2.1 Frequency band 433.050-434.790MHz ............................................................. 2.2 Frequency band 915-928MHz ........................................................................... AUTEC LIAIRE12-01 2 Conformity Conformity 1.1 Conformity of frequency band 433.050-434.790MHz Each AIR series' radio remote control working in the frequency band 433.050-434.790MHz complies with the (R&TTE) Directive 1999/5/EC and its essential requirements. Each radio remote control is also in conformity with the harmonised standards provided in the EC Declaration of Conformity. You can find the EC Declaration of Conformity on the website www.autecsafety.com, in the product page of the relevant transmitting unit. 1.2 Conformity of frequency band 915-928MHz: FCC and IC An AIR series' radio remote control working in the frequency band 915-928MHz complies with the essential requirements of the following regulations: -- FCC (Federal Communication Commission) Part 15 -- IC (Industry Canada) RSS-102 Unit FCC ID IC Number A8 transmitting unit OQA-A08LA0AM 9061A-A08LA0AM AJM transmitting unit OQA-AJMDA0BM 9061A-AJMDA0BM AJR transmitting unit OQA-AJRDA0BM 9061A-AJRDA0BM AJS transmitting unit OQA-AJSDA0BM 9061A-AJSDA0BM Transmitting unit LK6/LK8 OQA-LKNLA1CM 9061A-LKNLA1CM Transmitting unit LK6 DF OQA-LKNDA1DM 9061A-LKNDA1DM Receiving unit G ACRS13-G OQA-RGAGA00M 9061A-RGAGA00M a b c Receiving unit G DCRS13 OQA-RGEBA00M 9061A-RGEBA00M a b c Receiving unit L ACRS13-L OQA-RLBHA00M 9061A-RLBCA00M a b c Receiving unit M ACRM15 OQA-RMCEA00M 9061A-RMCEA00M a b c Receiving unit HACRP8 OQA-RPDFA00M 9061A-RPDFA00M a b c Receiving unit MVRCAN OQA-RNFLA00M 9061A-RNFLA00M a b c Receiving unit MVRL9E OQA-RRLPA00M 9061A-RRLPA00M a b c LIAIRE12-01 AUTEC - Air series Frequencies a. b. c. d. Receiving unit DCRM24 OQA-RMGMA00M Receiving unit ACRM5E OQA-RMHN00M 9061A-RMGMA00M a b c 9061A-RMHNA00M a b c Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna type Antenna gain Antenna impedance Autec stylus λ/4 <0dBi 50 Ohm Autec allows you to use only the dedicated antenna supplied either with the remote control or as original spare part. The use of any other type of antenna is prohibited and will invalidate the guarantee. Place the antenna of the receiving unit in a position that ensures a minimum separation distance of 20cm with all the people that can be in the working area. 1.2.1 Federal Communications Commission (FCC) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 1.2.2 Industry Canada (IC) This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Frequencies AIR series radio remote controls can work at two different frequency bands: 433.050434.790MHz or 915.000-928.000MHz. AUTEC - Air series LIAIRE12-01 4 Frequencies The radio remote controls' working frequency is defined by market-specific laws and standards. In order for the system “machine+radio remote control” to be compliant and therefore to be used, it shall comply with such laws and standards: if it does not, the system may be impounded by competent bodies. Autec cannot be held responsible if the radio remote control is set with forbidden frequencies. They automatically search for a free working frequency. 2.1 Frequency band 433.050-434.790MHz 2.1.1 Frequencies The radio link between the units of Autec AIR series radio remote controls is established at one of the frequencies permitted by the European standards in force when the system is put on the market. Frequencies used in the band 433.050-434.790MHz ...................................................... 64 RF power ................................................................................................................. <1mW Channel spacing ...................................................................................................... 25kHz 2.1.2 Market Air series' radio remote controls working in the frequency band 433.050-434.790 MHz can be used within the EU (European Union), the EFTA (European Free Trade Association), in Australia and in Singapore. 2.2 Frequency band 915-928MHz 2.2.1 Frequencies The radio link between the units of Autec Air series radio remote controls is established at one of the frequencies permitted by the US, Canadian and Australian standards in force when the system is put on the market. Frequencies used in the band 915-928MHz ................................................................. 255 RF power (FCC and IC) .................................................... meets FCC and IC requirements Channel spacing ...................................................................................................... 50kHz 2.2.2 Market Air series' radio remote controls working in the frequency band 915-928MHz can be used in the US, Canadian and Australian markets. Check on the technical data plate of the units in which markets the radio remote control can be used. LIAIRE12-01 AUTEC - Air series
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2015:07:03 17:29:28+02:00 Metadata Date : 2015:07:03 17:29:29+02:00 Modify Date : 2015:07:03 17:29:29+02:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:f1d11d57-dab8-4121-a2f6-8a31090ba6fb Original Document ID : xmp.did:3E97F9BFF011E111AF74C00038EEA0BF Document ID : xmp.id:990E714B9821E511B219F68D98665485 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:0BA6AF359821E511B219F68D98665485 Derived From Document ID : xmp.did:0BA6AF359821E511B219F68D98665485 Derived From Original Document ID: xmp.did:3E97F9BFF011E111AF74C00038EEA0BF Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2015:07:03 17:29:28+02:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Layout : SinglePage Page Count : 4 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools