Automatic Bar Controls CF001 Beverage Dispensing Data Collection User Manual CFU INSTRUCTS 09 04 13 pub
Automatic Bar Controls, Inc. Beverage Dispensing Data Collection CFU INSTRUCTS 09 04 13 pub
Users Manual
For Systems with the model number: CF-001 External, 5 VDC, 1 Amp CONTENTS PAGE NUMBER Safety and Warnings / Sécurité et Avertissements……. CFU Front and Left Side Features……..………………….. 3–4 CFU Rear Panel Features…...………………………………. 4—5 Mounting Points……...…..…………………………………... Set-Up Instructions…………………..………………...……. SERVICE AND FACTORY ASSISTANCE: Please record your Installer/Service Agent's name and phone number here for future reference: SERIAL NUMBER: ____________________ DATE OF INSTALLATION: ____________________ SERVICE AGENT NAME: ___________________ PHONE: _______________ PAGER: ______________ Service Assistance: call Wunder-Bar "Toll Free Service Hotline" @ 866-986-3372 anytime, or (707) 448-5151 Monday through Friday, 7:00 AM to 5:00 PM Pacific Time. REV090413 Setting the standards for over 40 years. CFU INSTRUCTS.pub www.wunderbar.com This Instruction Manual describes the different hardware functionalities of the Cloudflo® Unit (CFU). The CFU is the main component of the Cloudflo® System. It receives wireless messages from external RF wireless devices like Skyflo® Spouts and Beerflo® meters. It stores pour data, and enables a remote system to retrieve and generate informative reports. This Instruction Manual is intended to provide a technician/installer/manager the ability to learn about the CFU’s physical attributes and functions to assist with installation, operation, and maintenance. ATTENTION! • • • • • • • • • • • • • Read all Instructions before setting up or operating the CloudFlo® Unit. Install and use the CloudFlo® Unit only as described in this instruction manual. Use only the manufacturer’s recommended power supply, cables, and accessories. Always disconnect the power supply from the electrical source before removing the CloudFlo® Unit cover or attempting any servicing of internal parts or components. Do not operate the CloudFlo® Unit if the power supply has been damaged, if the power supply has a damaged cord, or if the CloudFlo® Unit has been damaged – until any damage has been examined by a qualified CloudFlo® service technician. The CloudFlo® Unit should never be exposed to or sprayed with excess water or moisture. Clean with a damp cloth, only. There are no End-User serviceable parts or components inside the CloudFlo® Unit enclosure. The CloudFlo® Unit’s cover should only be removed by, and internal parts and components serviced by a qualified service person with the knowledge, experience, and training for servicing of the CloudFlo® Unit. The CloudFlo Unit should be operated in these ambient temperatures: MIN: 36° F, 2° C MAX: 104° F, 40° C IMPORTANT! Changes or modifications not expressly approved by Automatic Bar Controls, Inc could void the user’s authority to operate the equipment. Lisez toutes les instructions avant d'installer ou de faire fonctionner l'unité CloudFlo®. Installez et utilisez l'unité CloudFlo® uniquement comme décrit dans ce manuel d'instruction. Utilisez seulement recommandé alimentation, les câbles et les accessoires du fabriquant. Toujours débrancher l'alimentation de la source électrique avant de retirer le capot de l'unité CloudFlo® ou de tenter toute réparation de pièces ou de composants internes. Ne pas faire fonctionner l'unité CloudFlo® si l'alimentation a été endommagé, ou si l'alimentation a un cordon endommagé, ou si le CloudFlo® appareil a été endommagé - jusqu'à ce que tout dommage a été examiné par un technicien qualifié. L'Unité CloudFlo® ne doit jamais être exposé ou pulvérisé avec de l'eau en excès ou à l'humidité. Nettoyer avec un chiffon humide seulement. Il n'y a aucune pièce réparable par l'utilisateur final ou de composants à l'intérieur de l'enceinte de l'unité CloudFlo®. La couverture du CloudFlo® Unité ne doit être retiré par, et ses composants internes que par un personnel de service qualifié les connaissances, l'expérience et la formation pour l'entretien de l'unité CloudFlo®. IMPORTANT! Les changements ou modifications non expressément approuvés par les contrôles automatiques de barres, Inc pourraient annuler l'autorité de l'utilisateur à utiliser l'équipement. FCC Statement: The CloudFlo Unit complies with Part 15.19 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Canadian IC Statement: The CloudFlo Unit complies with the Industry Canada license– exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. CloudFlo Unit M/N: CF-001 FCC ID: 2AAVJ-CF001 IC ID: 11358A-CF001 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus meets all requirements of- the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada. Setting the standards for over 40 years. www.wunderbar.com Ethernet Status Data Flow Status POS Data Flow Status Power USB Backup Port Data Export Button Data Alarm Button FRONT AND LEFT SIDE PANELS LED1: PWR OFF GREEN RED CFU power is OFF Steady green when the CFU is powered on and is connected to external 5V power supply Steady red when the CFU is powered on and running on internal battery LED2: POS OFF GREEN RED No serial line activity Blinks green every time a data packet is sent to the POS system Blinks red when a NACK is received from the POS or a communication error occurs LED3: Flo/Err OFF GREEN RED No RF radio activity Blinks green every time a radio packet is sent or received to/from the field devices Blinks red when the internal buffer is almost* full, indicating data needs to be exported LED4: LAN OFF GREEN YELLOW No Ethernet connection Steady green when an Ethernet connection is detected (active network cable is attached) Blinking yellow every time a data packet is sent or received on the Ethernet interface * The threshold of empty space available that triggers this condition can be configured in the software. CFU LEFT SIDE: USB BACKUP PORT AND BUTTONS USB PORT Insert USB memory device before pressing Data Export Button BACKUP BUTTON Push button to trigger data export procedure to a USB memory device attached to USB port ALARM MUTE BTN Press to silence “data full” alarm buzzer for a period of time. The alarm buzzer will sound again if data has not been exported after a period of time. (see alarm functions on page 4) Setting the standards for over 40 years. www.wunderbar.com FRONT AND LEFT SIDE PANELS (Continued) ALARM FUNCTIONS Shutdown in progress When the power supply is disconnected from the CFU, one short beep will be emitted and the CFU will begin an automatic shut-down procedure. Available buffer space When the internal data storage is almost full, the alarm starts beeping every two seconds to signal the need to export data (to an attached PC or memory device). The alarm stops below Threshold beeping when data is successfully exported or after the alarm is silenced by pressing the Alarm Mute Button (see page 3, ALARM MUTE BTN). Data export in progress One short beep is emitted when an export procedure, to a USB memory device, is started. When the data export is completed, two short beeps are emitted. If an error occurs during the export, one long beep is emitted. REAR PANEL Antenna Antenna Ethernet Ports Power Input RS-232 Port Reset/Update Button USB Service Port REAR PANEL FEATURES Twin RF Antennas Two RF antenna masts are included with the CFU. Install an antenna onto both of the Antenna mounts and hand-tighten by nut to the right (clockwise). Do not attempt to operate with only one antenna as CFU performance will be dramatically reduced. Power Input Attach the 100—240 VAC to 5 VDC Power Supply that was provided with the CFU by fully inserting the Power Supply’s connector into the CFU’s PWR socket. RS-232 Port For “Front of the House” POS interfacing. RS-232 port is a standard D-sub 9pin male connector (DB-9 / DE-9M). Dual LAN Ports Two 10/100Mbit Ethernet ports on RJ-45 standard connectors. Either of these two ports can be used for the purposes of interfacing with the CFU. Additionally, the port not in use can be used as a “switch” port for another CFU and to “Daisy Chain” CFU’s. An example of the use of this capability would be a possibility that a bar location could have 2-3 POS systems, but only one network cable available to the Bar. The main cable that makes the network available could be plugged into a CFU. The other CFU’s could link back across the same “main cable” through the use of the “Daisy Chain” between CFU’s. Setting the standards for over 40 years. www.wunderbar.com REAR PANEL (Continued) RESET / UPDATE BUTTON Hardware Reset In the unlikely event of an CFU embedded firmware crash: FIRST: Press and hold the Reset/Update Button for more than 7.5 seconds while the CFU is running and the CFU software will reset, regardless of its logic state. SECOND: If a Reset/Update attempt does not correct the problem, unplug the CFU and wait for the internal battery to deplete completely (the PWR indicator light will be steady red until all battery power is depleted). When the red PWR light goes out, attach the power supply to restart the CFU. Factory Restore To restore the CFU's embedded firmware, power up the CFU. After 5 seconds the LED2, LED3 and LED4 will go through this sequence, where 1 is green light, cycling every second: 1. 2. 3. 4. 5. 100 110 111 011 011 During this sequence press and hold the Reset/Update button, the same sequence will occur with red light. A couple of seconds after the sequence, the three leds will start flashing independently, indicating the factory restore procedure is in progress. Once initiated, the restore procedure must not be interrupted or the CFU may require servicing. WARNING: All stored data and configuration information are irreversibly deleted during the Factory Restore process. MOUNTING POINTS Two mounting points are located on the underside of the CFU (see red squares). The CFU my be secured to a horizontal or vertical surface using two (2) #8 pan head screws that are specific to the material the CFU is to be mounted to. Setting the standards for over 40 years. www.wunderbar.com SET-UP INSTRUCTIONS SET-UP FIRST Attach both antennas to the CloudFlo® Unit and tighten the Antenna Mounting Nuts until they are finger tight. Do not over-tighten the Antenna Mounting Nuts using a pliers or damage may result. SECOND Connect the Power Supply to the CloudFlo® Unit by inserting the Power Supply’s plug into the rear panel socket labeled PWR. (see page 4 of this manual) THIRD Wait about two minutes for the CloudFlo® Unit to “boot up” and load all operation files. FOURTH Make sure that your PC or MAC is set-up to receive an IP address over DHCP. FIFTH Use a network cable to connect your PC or MAC to either one of the LAN ports located on the rear panel of the CloudFlo® Unit. (see page 4 of this manual) SIXTH On your PC or MAC: Open a browser and go to http://192.168.0.14 to configure your CloudFlo® System. NOTE: Your PC or MAC must also have a unique IP address and exist on the same subnet as: 192.168.0.14. For example: 192.168.0.15.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:09:04 16:42:49-07:00 Create Date : 2013:09:04 16:42:49-07:00 Format : application/pdf Title : CFU INSTRUCTS 09-04-13.pub Creator : jim Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:a978e759-f6f1-432b-9da5-d2daa06cb079 Instance ID : uuid:b1980059-1e38-4f3d-a8df-054319e104b0 Page Count : 6 Author : jimEXIF Metadata provided by EXIF.tools