BEWELL CONNECT BW-SCB1 MyBabyScale User Manual

BEWELL CONNECT CORP MyBabyScale

User Manual

Download: BEWELL CONNECT BW-SCB1 MyBabyScale User Manual
Mirror Download [FCC.gov]BEWELL CONNECT BW-SCB1 MyBabyScale User Manual
Document ID3111538
Application IDspvmwFkk1EXnHua22JVaRQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize68.59kB (857426 bits)
Date Submitted2016-08-25 00:00:00
Date Available2016-08-31 00:00:00
Creation Date2016-07-12 15:59:51
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-07-21 14:13:24
Document TitleUser Manual
Document CreatorAdobe InDesign CC 2015 (Macintosh)

Accessoires fournis
EN
Un pèse-personne connecté, une
notice, un guide d’installation
rapide, 2 piles LR6-AA
8. GUIDE DE DÉPANNAGE
Si l’un des problèmes suivants survient lors de l’utilisation de votre
MyBabyScale®, reportez-vous à ce guide de dépannage. Si le problème persiste, veuillez contacter notre support Clients.
“LO”
s’affiche
“O-LD”
s’affiche
18
CAUSE(S)
POSSIBLE(S)
SOLUTION
Piles usagées
Insérer des piles
neuves.
Avertissement de
surcharge
Le poids maximal
supporté par la
balance est de 50kg.
Retirez immédiatement le poids
de la balance, des
dommages irréversibles pourraient être
causés à l’appareil.
BewellConnect - BW-SCB1 - User Manual - 072016
MyBabyScale
ERREUR À
L’ÉCRAN
BW-SCB1
BewellConnect - BW-SCB1 - User Manual - 072016
19
THIS PRODUCT CONFORMS TO REACH STANDARD (ROHS)
CONTENTS
1. WARNINGS
2. INFORMATIONS
2-2. CHILD’S GROWTH CURVE
2-3. ABOUT BMI - BODY MASS INDEX
2-4. CALCULATING BMI IN CHILDREN
3. USING THE DEVICE
3-1. PRECAUTIONS BEFORE USE
3-2. USING THE BABY SCALE
3-3. CHANGING THE BATTERIES
4. USING THE APP
4-1. DATA TRANSFER
4-2. APP FEATURES
5. CLEANING AND MAINTENANCE
6. AVOIDING MALFUNCTIONS
7. TECHNICAL SPECIFICATIONS
8. TROUBLESHOOTING GUIDE
Find out how to install and use the BewellConnect® app by logging on to our website www.bewell-connect.com/install
The manufacturer reserves the right to change the technical
specifications of the product without prior notice.
20
BewellConnect - BW-SCB1 - User Manual - 072016
21
22
23
24
24
25
25
25
27
28
28
29
29
30
30
31
Dear customer,
You have just bought MyBabyScale®, the connected baby scale by
BewellConnect®, and we thank you for your custom. We hope that
you enjoy using it and recommend reading this user guide carefully.
1. WARNINGS
- Use this device only for its intended purpose, as described in this
guide.
- This device can be used for personal use at home.
- Use this device in an ambient temperature range between 10 and
40°C.
- Do not expose this device to extreme temperature conditions
> 60°C or < -20°C.
- Do not use this device in relative humidity higher than 85%.
- This device must be placed on a stable surface when using the
tray.
- Never leave your baby unsupervised, even for a moment, in particular when the baby is placed on the tray.
- This device should always be placed in a clean, dry place.
- Do not expose this device to sunlight or water.
- Do not expose this device to electrical shocks.
- Never drop the device.
- Follow the maintenance instructions stipulated in this guide.
- Do not attempt to open the device. In the event of a problem,
contact your retailer.
- Do not leave this device within children’s reach.
- The measurement results are given for information only. If there
is any doubt regarding your results, please contact your paediatrician.
- Discontinue using the device in the event of anomalies or malBewellConnect - BW-SCB1 - User Manual - 072016
21
functions.
- In general, portable and mobile RF communication equipment
does not affect the functioning of medical electronic equipment.
However, it cannot be used in environments with high electromagnetic interference: near a television, microwave oven, etc.
- Do not use any batteries other than those listed, do not recharge
non rechargeable batteries, do not throw them into fire.
- Remove the batteries if the device is not in use for a long period.
- This device is not designed to be used by people (including children) with reduced physical, sensory or mental abilities, or people
without experience or knowledge, unless they are able to benefit
from it through the intermediary of a person responsible for their
safety, under supervision or following prior instructions on how
to use this device.
IMPORTANT: PLEASE OBSERVE THE POLARITY OF THE BATTERIES.
A POLARITY ERROR MAY CAUSE DAMAGE TO THE DEVICE
AND COMPROMISE THE WARRANTY.
2. INFORMATIONS
During their stay in the maternity ward, baby is weighed every day
to monitor weight loss and gradual return to birth weight. When
they arrive home, it is advisable to weigh them 1 to 3 times a week,
always under the same conditions. Monitoring weight is one of the
main indicators of good health. Delayed or excessively fast growth is
sometimes a sign of a disease or disorder. Regular monitoring makes
it possible to see changes in weight, particularly when your baby is
struggling to feed. Most infant scales only cover a limited period of
time. That is why BewellConnect® had developed MyBabyScale®, the
smart, scalable, connected wireless baby scale that lets you keep
track of your child’s weight from birth all the way to adolescence.
22
BewellConnect - BW-SCB1 - User Manual - 072016
2-1. BABY’S WEIGHT
A baby grows the most in its first year, gaining around 6 kg in the
first 12 months then just 3 kg the following year. It is important
to avoid excess weight gain by only feeding your baby what he
or she needs. However, bear in mind that a baby grows in stages,
with pauses, and that there are great height and weight variations
between individual children.
2-2. CHILD’S GROWTH CURVE
Regularly monitoring your child’s growth makes it possible to
create curves (Height and weight, CF 4. APP). It is very important
to attentively monitor baby’s weight gain. A baby loses weight in
the three or four days following birth. This is a normal phenomenon. As soon as baby has returned to its birth weight, growth will
continue evenly
Using the MyBabyScale® app, you can create
curves tracking your child’s weight and
height (according to WHO standards) and
show them to your doctor regularly.
BewellConnect - BW-SCB1 - User Manual - 072016
23
The table opposite shows the recommended weights for a healthy
baby.
AGE
WEIGHT GAIN
0 to 3 months
25 to 30g/day
3 to 6 months
20 to 25g/day
6 to 9 months
15 to 25g/day
9 to 12 months
10 to 15g/day
Warning
Do not put your child on a diet without consulting a doctor first.
Analysis and interpretation of BMI data must be performed by a
healthcare professional (general practitioner, paediatrician, school
doctor).
2-3. ABOUT BMI - BODY MASS INDEX
A study by American researchers from Harvard University found
that if BMI increases during the first 6 months, the child is more
likely to suffer from premature obesity at 3 years. BMI is an indicator of corpulence and potential medical risks, based on the ratio of
weight to height. The corpulence curve helps to identify children
who are obese or at risk of becoming so: the child is obese if their
BMI is above the 97th percentile. BMI increases in the first year and
then decreases until the age of 6 before increasing again. This rise,
which occurs on average at 6 years, is called adiposity rebound.
The earlier the adiposity rebound takes place, the greater the risk
of obesity. An upward percentile crossing is a warning sign.
2-4. CALCULATING BMI IN CHILDREN
The child’s BMI is calculated using the following formula: BMI =
24
BewellConnect - BW-SCB1 - User Manual - 072016
weight (in kilograms) / (height (in metres) x height (in metres)). For
example, for a 9-year-old girl weighing 19 kg and measuring 1.10
metres, the BMI will be: BMI = 19 / (1.1 x 1.1) or 19 / 1.21 = 15.70.
As you can see, the resulting BMI for the child in question (15.70) is
entirely in line with the average growth chart for girls.
3. USING THE DEVICE
3-1. PRECAUTIONS BEFORE USE
- T he child should not be left unsupervised when using the device.
- P lace the baby scale on a solid, flat, skid-proof surface (avoid placing it on a carpet, for example).
-W
 eight varies throughout the day, so we recommend weighing
before meals to obtain comparable results. It is advisable to take
the weight measurement at the same time every day, preferably
on an empty stomach.
3-2. USING THE BABY SCALE
HOLD
lb
OZ
kg
Display
Unit of mass
5 Hold
Bluetooth
Battery charge status
Overload warning: Immediately remove the child placed on the
BewellConnect - BW-SCB1 - User Manual - 072016
25
scale if “O-Ld” appears on the screen. Irreversible damage could be
caused to the device.
DESCRIPTION
View diagram page 2
a Base
b Disc for weighing a child/teenager
c Baby tray
First use
Remove the cover from the battery compartment underneath the
device. Insert 2 1.5V LR06-AA type batteries. Turn on the baby scale
using the “on/off” button.
Choosing the unit of weight
After pressing the on/off button to turn on MyBabyScale®, press
the “on/off” button again to choose the unit of weight in “lb & oz” or
“kg” before the figure “0.00” appears on the screen.
EN
26
BewellConnect - BW-SCB1 - User Manual - 072016
CL
OS
OP
Attaching the tray (FIG. 1) or disc (FIG. 2) to the base
Turn the base upside down. Unlock the locking mechanism (FIG. 3)
by turning it to open. Insert the tray or the disc into the base using
the notches. Turn the locking mechanism (FIG. 3) to close while holding the scale or disc in place. Make sure that the tray is securely
locked before weighing the child.
Starting up
- P lace the baby scale on a flat, solid surface, making sure that it
is stable and that nothing touches it. Press the «on/off» button.
-O
 n first use, the figures flash during weighing. The baby‘s weight
is displayed on the screen at the same time as the word „hold“. The
scale will turn off automatically. On subsequent uses, the previous
weight recorded is displayed at startup.
- T o perform another weighing, remove the baby from the scale.
Press the „hold“ button until the „0.00 kg“ figure appears on the
screen.
- I f you wish to place a towel under the baby before weighing it, put
it on the scale before turning it on. Press the “on/off” button and
place the baby on the tray when “0.00” appears on the screen. The
scale automatically performs the calculation and only displays the
baby’s weight (at the same time as the word “hold”).
-A
 fter weighing, remove the baby at the same time as the towel. A
negative value will appear, press “tare” to reset the scale to zero for
future weight measurements.
-W
 hen the child is able to stand, replace the baby weighing tray
with the disc.
Do not use the disc to weigh a child that cannot yet stand.
Shutdown
- T he device shuts down automatically after displaying the weight
(approximately one minute).
- T he device can be shut down manually by pressing the “on/off” button.
3-3. CHANGING THE BATTERIES
- T he battery compartment is located at the back of the device.
-W
 hen using it for the first time, insert 2 new 1.5V LR6-AA batteries
BewellConnect - BW-SCB1 - User Manual - 072016
27
into the scale.
-W
 hen the LCD screen displays “LO”, the batteries are low or used
up. Replace used batteries, taking care to observe the polarity. A
polarity error may cause damage to the device and compromise
the warranty.
-N
 ever insert rechargeable batteries. Use single-use batteries only.
Do not mix new batteries with used batteries.
-D
 o not throw your used batteries out with household waste.
- Take your used batteries to a collection point.
Remove the batteries if the device is not in use for a long period, in
order to avoid any leaks that may damage the unit.
4. USING THE APP
4-1. DATA TRANSFER
Download the BewellConnect® app
Download the BewellConnect® app from your smartphone
or tablet store. (App Store for an iOS device, Play Store for
bw
an Android device)
BabyScale
First use – Programming personal data
- S tart by creating profiles for yourself and your children
- P rogramme the profiles by entering age, height and sex
Taking the measurement
- T o track your child’s growth, connect your device (telephone, tablet) using Bluetooth (Bluetooth 4.0 smart Low Energy connectivity, compatible with iPhone 4s and up).
- T urn on the scale by pressing the on/off button.
-O
 pen the BewellConnect® app and choose your child’s profile.
- S tart MyBabyScale® and go to the measurement screen before
weighing your child, to save the data.
28
BewellConnect - BW-SCB1 - User Manual - 072016
- P lace the child on the baby scale.
-D
 ata are measured and transferred to the smartphone or tablet
automatically with MyBabyScale®.
- Y ou can consult the growth curves in the app.
4-2. APP FEATURES
MyBabyScale® lets you track your baby’s growth (weight and
height). However, other features are also available:
-G
 rowth: Size, head circumference, arm circumference and waist
circumference.
- B reastfeeding: breastfeeding duration on the right breast, breastfeeding duration on the left breast.
- B ottles: quantity of bottles, expressed milk or powdered milk.
- S leep: duration.
-N
 appy: consistency and amount of stools/urine.
-M
 ood: it is possible to add your baby’s mood whenever you enter
a new measurement. There is also the option to indicate whether
there has been any regurgitation.
The app helps you to achieve successful dietary diversification, providing advice on introducing foods into your baby’s diet from 0 to
3 years of age.
5. CLEANING AND MAINTENANCE
- Do not allow the weighing tray to become wet as this could make
it slippery and cause an accident.
- Store your baby scale horizontally.
- Store your baby scale in a dry place and away from moisture.
- Use a soft, dry cloth to clean the unit. If necessary, use a cloth
moistened slightly with tap water.
- Do not use alcohol, benzene, thinner or other chemicals to clean
the device.
- This product is not waterproof, avoid contact with liquid.
BewellConnect - BW-SCB1 - User Manual - 072016
29
- If the unit has been exposed to temperatures below 0°C, be
sure to leave it for 30 minutes at room temperature before use.
Without this waiting period, the results could be wrong.
- If the baby scale is not in use for a long period of time, be sure to
remove the batteries (they could damage the device).
- Do not use rechargeable batteries.
6. AVOIDING MALFUNCTIONS
- Do not drop the device, avoid jolts and shocks.
- Do not insert anything into the device, excluding batteries.
- Do not disassemble the baby scale.
- Do not put the device in water.
7. TECHNICAL SPECIFICATIONS
Product name
BewellConnect® MyBabyScale®
Reference
BW-SCB1
Units of weight
Ib:oz /kg
Item
Units
Minimum
Maximum
Weighing measure ment range
kg
0.04
50
Ib oz
1.5
99Ib 15.5oz
kg
0.01
oz
0,5
Division
Dimensions
420 x 340 x 100 mm
Weight
1.82kg
Normal conditions
of use
Temperature: 5 - 35°C
Humidity: 20 - 80%
Storage conditions
Temperature: -10 - 50°C
Humidity: 20-80%
Bluetooth
technology
4.0 smart Low Energy
Power supply
2 LR6-AA batteries (supplied)
Low battery
indicator
“LO”
Battery life
3-4 months (for 4 daily measurements) Low battery indicator
Automatic
shutdown
1 minute
Accessories
supplied
One connected scale, one user
guide, one quick setup guide,
2 LR6-AA batteries
8. TROUBLESHOOTING GUIDE
If any of the following problems occur when using your
MyBabyScale®, please refer to this troubleshooting guide. If the
problem persists, please contact our customer support service.
Overload indicator “O-Ld”
30
BewellConnect - BW-SCB1 - User Manual - 072016
BewellConnect - BW-SCB1 - User Manual - 072016
31
SCREEN
ERROR
POSSIBLE
CAUSE(S)
“LO” appears Batteries used up
Insert new batteries
“O-LD”
appears
The maximum
weight supported
by the scale is 50kg.
Immediately remove
the weight from the
scale, or irreversible
damage may be
caused to the device.
MyBabyScale
Overload warning
ES
SOLUTION
32
BewellConnect - BW-SCB1 - User Manual - 072016
BW-SCB1
BewellConnect - BW-SCB1 - User Manual - 072016
33

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2016:07:12 15:59:51+02:00
Creator                         : Adobe InDesign CC 2015 (Macintosh)
Modify Date                     : 2016:07:21 14:13:24+08:00
Has XFA                         : No
Language                        : fr-FR
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2016:07:21 14:13:24+08:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Instance ID                     : uuid:de9ca6c7-d36d-437e-b28c-7e67f50f2004
Original Document ID            : xmp.did:db286c07-c48a-48f5-8c9d-43698e23fb34
Document ID                     : xmp.id:c8a44bf4-0579-448d-971b-4a47be3a11fd
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:74815a3f-0462-4502-9be2-ab385e50c4a3
Derived From Document ID        : xmp.did:2cb92a04-ea44-4ae4-aa26-1cb95c63d9bc
Derived From Original Document ID: xmp.did:db286c07-c48a-48f5-8c9d-43698e23fb34
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2016:07:12 15:59:51+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AF8T-BW-SCB1

Navigation menu