BIG KING HORN SPEAKER ENT 111BP TRANSMITTER User Manual 500 550 Manual RFID New TX ICONS p65

BIG KING HORN SPEAKER ENT. CO., LTD. TRANSMITTER 500 550 Manual RFID New TX ICONS p65

User manual

Download: BIG KING HORN SPEAKER ENT 111BP TRANSMITTER User Manual 500 550 Manual  RFID   New TX ICONS  p65
Mirror Download [FCC.gov]BIG KING HORN SPEAKER ENT 111BP TRANSMITTER User Manual 500 550 Manual  RFID   New TX ICONS  p65
Document ID1623676
Application ID7riCsSvr1sPTSRLlN/jkPg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.19kB (314903 bits)
Date Submitted2012-01-18 00:00:00
Date Available2012-01-18 00:00:00
Creation Date2012-01-04 11:53:33
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2012-01-04 11:56:18
Document Title500-550 Manual (RFID & New TX ICONS).p65
Document CreatorPageMaker 6.5
Document Author: Hircio

11.
1 Dome-Light or Window Roll-Up: (•Dome-Light = 1 siren chirp / Window
Roll-UP = 2 chirps)
- Configures the alarm’s “Black/White” wire to operate the:
a. Dome-Light: Supply a (-) output when the alarm is Disarmed to illuminate the
vehicle’s Dome-Light for 30 seconds through the use of a relay, or
b. Window Roll-Up or accessory: Supply a (-) output for 30 seconds when the
alarm is Armed to operate a Window Roll-Up module or other accessory.
2 3rd Channel Output: (•Momentary = 1 siren chirp / Window Roll-UP =
12.
2 chirps)
- Configures the alarm’s “Pink” wire to operate an:
a. Accessory : Supply a (-) output as long as the small “4th” button on the remote
control, is pressed & held while the vehicle’s ignition is “Off”, (max 30 seconds).
b. Window Roll-Up or accessory: Supply a (-) output for 30 seconds when the
alarm is Armed to operate a Window Roll-Up module or other accessory.
13. Ignition Door Lock/Unlock: (•On = 1 siren chirp / Off = 2 chirps)
- Configures the alarm to Lock the vehicle's doors when the ignition is turned
“On” and Unlock the vehicle’s doors when the ignition is turned “Off”.
14. “RFID” Add-On to Anti-Hijacking: (On = 1 siren chirp / •Off = 2 chirps)
- Adds an “RFID” layer to both the Ignition & Open Door activated Anti-Hijacking
features. (Note: Special RFID remote control required)
-Press hold TX' button 5 seconds,LED will flash,TX'RFID is turned "On".
-Press hold TX' button 5 seconds,LED will solid,TX'RFID is turned "Off".
0.80
Sec
4.0
Sec
JUMPER ON SIDE OF ALARM BRAIN:
Lock Pulse Time: ( • .80 seconds = Jumper “In” / 4 seconds = Jumper “Out”)
- Determines the length of the alarm’s door lock/unlock pulse output.
Page 12
Page 13
Siren
Pin-Switch (-)
Pin-Switch (+)
Pin-Switch (-)
Trunk
Release
15 Amp
(-)
Auxiliary
Output
Relay
Relay
Car Horn /
Claxon
Green - Verde = (-Lock, -Cierre)
Red - Rojo = (+12 Volts)
Blue - Azul = (- Unlock, - Apertura)
Café/con lista Blanca:
Este cable se puede programar (función #6), a sonar el claxon en conjunto
al cable Café operar la Sirena, O TOMAR TODAS LA FUNCIONES DE LA
SIRENA PARAQUE NO HAGA FALTA INSTALAR SIRENA.
Brown/White :
This wire can be configured (Programmable feature # 6), to honk the horn
in addition to the Brown wire operating the siren, or take over all of the
Siren’s functions SO THAT NO SIREN IS NECESSARY
Parking Lights / Luces
Brown - Café = (+Siren/Horn, +Sirena/Claxon)
Red - Rojo = (+12 Volts, +12 Voltios)
White - Blanco = (+Flashing Lights, +Luces)
Black - Negro = (-Ground, -Tierra)
Brown/White - Café/Blanco = (-Horn Output, Salida claxon -)
Black/White - Negro/Blanco = (-Dome-Light , Salida luz de cabina-)
Grey - Gris = (-Auxiliary output, Segundo canal auxiliar-)
Pink - Rosado = (-3rd channel output, Tercer canal-)
Orange - Naranja = (-Starter Kill, Corte -)
Blue - Azul = (-Trigger Input, Disparo -)
Violet - Violeta = (+Door Input, Puerta +)
Green - Verde = (-Door Input, Puerta -)
Yellow - Amarillo = (+Accessory, Ignición +)
Relay
DomeLight
0.80 4.0
Sec Sec
Door Lock Pulse Time Jumper
Valet/Override Button
K9 SS
LED Status Indicator
Optional
Sensor
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
Battery
Door Locking Systems / Sistemas De Cierre
Negative Trigger System / Sistema Negativo:
Doorlock
Actuators
Blue
Green
Unlock wire/ Cable de Apertura
Lock wire /
Cable de cierre
Unlock
Ground
Lock
Vehicle's Doorlock
Relay Control Unit
Doorlock Switch
Positive Trigger System / Sistema Positivo:
Doorlock
Actuators
Blue
Fuse
Green
87
87
(+)12 Volts
87a
87a
30
30
Unlock Relay
Lock Relay
Unlock wire/ Cable de Apertura
Lock wire /
Cable de cierre
Unlock
(+) 12 Volts
Lock
Vehicle's Doorlock
Relay Control Unit
Doorlock Switch
5 Wire Reversal (Rest at ground): Cambio de Polaridad:
Blue
Fuse
Green
87
87
Driver
Doorlock
Switch
30
30
Lock Relay
Unlock
(+)12 Volts
87a
87a
Cut both Lock and
Unlock wires in car
Unlock Relay
Passenger
Doorlock Switch
-Lock wire "Motor" side.
-cable de Cierre, lado Motor
Unlock
- Ground
- Lock wire "Switch" side.
-cable de Cierre, lado del switch
Lock
- Unlock wire "Switch" side.
-cable de Apertura, lado del switch
- Unlock wire "Motor" side.
-cable de Apertura, lado Motor
Page 14
Lock
Notice : The changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
IMPORTANT NOTE: To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the device is
permitted. Any change to the antenna or the device could
result in the device exceeding the RF exposure requirements
and void user’s authority to operate the device.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Modify Date                     : 2012:01:04 11:56:18+08:00
Create Date                     : 2012:01:04 11:53:33+08:00
Title                           : 500-550 Manual (RFID & New TX ICONS).p65
Author                          : Hircio
Creator                         : PageMaker 6.5
Producer                        : GPL Ghostscript 8.15
Page Count                      : 4
Mod Date                        : 2012:01:04 11:56:18+08:00
Creation Date                   : 2012:01:04 11:53:33+08:00
Metadata Date                   : 2012:01:04 11:56:18+08:00
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VGA111BP

Navigation menu