BRYANT Furnace/Heater, Gas Manual L1002531
User Manual: BRYANT BRYANT Furnace/Heater, Gas Manual BRYANT Furnace/Heater, Gas Owner's Manual, BRYANT Furnace/Heater, Gas installation guides
Open the PDF directly: View PDF .
Page Count: 6
Download | ![]() |
Open PDF In Browser | View PDF |
Installation Instructions NOTE: Read installation. the entire SAFETY instruction manual before starting the CONSIDERATIONS CUT Improper maintenance, installation, adjustment, or use can cause explosion, other conditions property damage. which may cause Consult a qualified alteration, fire, electrical death, personal installer, service service, shock, or injury, agency, or or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions Follow packaged all safety with the kits or accessories codes. Wear safety glasses, codes, the current editions Code (NFGC) NFPA 54/ANSI Electrical Code (NEC) NFPA 70. of the National Z223.1 and Fuel the National of Canada Installation CAN/CSA-BI49.1 and .2 Natural Gas and Propane Codes, and Canadian Electrical Code CSA C22.1 Recognize safety information. you this symbol This is the safety-alert on be alert to the potential Understand CAUTION. DANGER severe see the signal of the National Gas refer to the current manuals, words the unit Standards symbol Z_ and in instructions or for personal injury. DANGER, WARNING, and These words are used with the safety-alert symbol. identifies the most serious hazards which will result in personal injury or death. this caution may result in personal WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. to highlight suggestions which will result installation, reliability, or operation. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing furnaces. NOTE is used in enhanced UNIT DAMAGE HAZARD Failure to follow this caution dangerous operation. Label all wires controls. prior to may result Failure to follow this warning could injury, death and/or property damage. -760 and -761 in 40-in. (1016 furnaces. See Table 1 for kit usage. mm) NOTE: as PAM A releasing equivalent (must hydrocarbons and RTV are needed other before corn this Primary or contents 162, G.E. starting G.E. tall, canola condensing gas cooking spray oil, halogenated to prevent 6702, installation. sealant. RCD in 3-oz such contain (G.E. type of RTV through agent not nor aromatic sealant inadequate seal) or Dow-Corning DO NOT or 738) substitute 162 (P771-9003) any is available tubes. Cell Inlet primary AND USAGE Panel Kit when replacement of a cell inlet panel is required. SHOCK This Primary result servicing This instruction covers installation of the Primary Cell Inlet Panel Kit Part No. 320720-751, -753, -754, -755, -756, -757, -758, factory-installed ELECTRICAL when and INTRODUCTION Use AND in improper disconnection DESCRIPTION FIRE, EXPLOSION HAZARD iniury. clothing, In Canada, When editions to follow when installing. protective and work gloves. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions include in literature and attached to the unit. Consult local building HAZARD Failure Cell Inlet Panel Kit contains the following items: in personal Before installing or servicing system, always turn off main electrical and gas supplies to unit and tag with appropriate lockout. There may be more than one disconnect switch. Primary Burner Cell Inlet Panel 1 Box Gasket Cell Mounting Installation Screw No. 8D X 3/8-in.(10 Instructions 1 mm) 25 max 1 Table I - Kit Usage UNIT 340AAV 340MAV KIT PART NO. 320720-751 320720- 753 320720-754 Prior to S/N 3002A14578 350AAV 350MAV 353AAV 490AAV 352AAV 345MAV 351DAS 352MAr 353BAV PGgMXA 355MAV 355AAV 355BAV 58MCA 58MCB 58MEB 355CAV 58MXA 58MSA 58MEC 58MTA 58MVB 58UVB 58MTB 58MVC 58MXB 24040 36040 24040 36040 24060 24060 36060 48060 36060 48060 - - 36060 42060 36080 48080 36080 48080 36080 48080 36080 48080 .... .............. 42060 040 - 08 040-12 040 - 08 040-12 24040 36040 060 - 08 060 - 08 060-12 060 - 16 060-12 060 - 16 060-12 080-12 080-16 080-12 080-16 080-12 080-16 24060 060-14 060-14 36080 48080 42080 080-14 (Series 100) (Series A) 48100 48100 60100 60100 -- 48100 60100 60100 60100 60120 g 320720-757 320720- 100-16 100-16 100-16 100-20 100-20 100-20 120-20 120-20 100-20 100-20 120-20 120-20 040-14 040-14 080 - 14 080-14 (Series 110 and -- 60120 ........ 60120 60120 320720-761 After S/N 3002A14577 60080 36080 48080 48100 60100 42040 42040 60120 140-20 ...... 42080 320720 - 760 - - 120-20 60120 60140 758 36060 48060 .... .................. 320720 - 755 320720-756 PGgMAA PGgMAB 58MVP 60080 36080 48080 60080 36080 48080 _ _ 36080 48080 (Series B 42080 and later) 60080 60080 .... - - 080-20 080-12 080-16 080-12 080-16 - - 60080 later) 080-20 .... 36080 48080 16. If control center was removed from furnace casing, secure control center (and J-box) to manifold for removal purposes only. Remove Whole Cell Panel Assembly See Fig. I and Fig. 2 for furnace component locations. See Fig. 3 for expanded view of heating system components. may vary depending 080 - 20 080-12 080-16 INSTALLATION NOTE: Actual component locations model and series. 080 - 20 60140 on 1. Turn off gas and electrical supplies to furnace. 2. Remove main furnace door. 3. Remove blower access panel. 4. Disconnect field power supply wires from J-box. 5. Remove two screws securing J-box. 6. Remove two screws securing top filler panel and rotate panel upwards to remove or allow the heat exchanger to be removed from front of furnace. 7. Disconnect combustion-air intake pipe from intake housing and move pipe out of furnace casing. 8. Disconnect gas supply pipe from gas valve using backup wrench. 9. Disconnect vent pipe from inducer housing by loosening coupling clamp on inducer outlet. If coupling has 2 clamps, loosen clamp on vent pipe side. Move pipe out of furnace casing. 10. If control center is located in burner compartment of furnace, remove blower motor leads, transformer wires, door switch wires, and auxiliary limit switch wires (if present) from control center and pull wires through blower shelf. 11. If control center is located in blower compartment of furnace, disconnect wires from flame sensor, hot surface igniter, overtemperature switch, gas valve, pressure switch(es), inducer motor, limit switch, and J-box, then pull wires through blower shelf. 12. Remove two screws securing blower to blower shelf (four screws on 120 and 140 sizes). 13. Remove two screws next to blower mounting screws that secure blower shelf to cell panel. 14. Remove three screws from each side of cell panel. 15. If control center is located in burner compartment of furnace, remove control center by removing screw and pressing tabs inward. 17. Disconnect field drain connection from condensate trap. 18. Disconnect drain and relief port tube from condensate trap. 19. Remove condensate trap from furnace casing or blower shelf. 20. Remove whole cell panel assembly with heat exchanger, burner box, inducer assembly, J-box (if applicable), and control center (if applicable) attached through front of furnace. PERSONAL Failure INJURY to follow HAZARD this caution Whole cell panel assembly lift assembly. Remove Burner may result in personal iniury. is heavy. Get help to remove and Box Assembly 1. If not previously disconnected, disconnect wires or connectors to overtemperature switch, gas valve, igniter, and flame sensor. 2. Remove pressure switch tube from intake housing. 3. Remove two screws attaching box, and rotate intake housing removal. 4. Disconnect 5. Remove NOTE: Burner assembly should pressure screws box tubing attaching cover, be removed intake housing to burner away from burner box for from gas valve. burner manifold, box to cell panel. gas as one assembly. valve, and burner COMBUSTION-AIR INTAKE CONNECTION GAS VALVE AUXILIARY JUNCTION BOX VENT OUTLET CONDENSING HEAT EXCHANGER (BEHIND CELL INLET PANEL) PRESSURE SWITCHES INDUCER MOTOR CONDENSATE ' TRAP MOTOR AND -BLOWER ASSEMBLY BURNER ENCLOSURE PRIMARY HEAT EXCHANGER (BEHIND CELL INLET PANEL) -- -_ COMBUSTION- AIRINTAKE PRIMARY HEAT EXCHANGER (BEHIND CELL INLET PANEL) ' CAP AND CLAMP (UNUSED DRAIN CONNECTION) VENT OUTLET CONTROL CENTER "BLOWER ACCESS PANEL SAFETY INTERLOCK SWITCH AIR FILTER AND -RETAINER -_ -_ .:_ .... (-.) _ J _: :x_ F" .-_A_ _ CONNECT,ON BOX '1 VENT OUTLET -INDUCERMOTOR-- __ / 11 __, Itl ft_/3 _l _--_ .__..- I:,P-'r',_=_-_ ! _ -__ ._"_ _---__l ! I _ l) \::,_ \-'_ I I II (U USED DRAIN I II I .h_-_ ' ..._. ,_ CONN.) INDUCER 4,tl OUTLET _ DRAIN TUBE /A __ __U_\ _, q_ _'\--,_\ x3_ AIR FILTE_ AND RETAINER N A(0 PRESSURE tl CENTER ........ HOUS,NG Z CONDENSATE TRAP I SWITCHES ,._ --" CONTROL EEEEEE_ ,NDUCER-- AND id#--O A OA CONDENSING-HEAT EXCHANnER (BEHIND C_LL INLET PANEL) GAS VALVE _X_'II_ II AOX,L,A -- JUNCTION BURNER ENCLOSURE _ II /_C_EVV_ 11 SAFETY INTERLOCK II PANEL A01026 Fig. 1 - Two-Stage, Two-Speed and Fixed-Capacity Model(s) in Upflow Orientation Remove Inducer Assembly 1. If not previously disconnected, disconnect inducer motor wire connector at quick-connect. 2. If not previously disconnected, disconnect pressure switch wires. 3. Remove collector box pressure switch tube from pressure switch. 4. Remove four screws attaching inducer housing to cell panel. NOTE: Inducer housing, inducer motor, and pressure switch(es) should be removed as 1 assembly. Install Primary Cell Inlet Panel 1. Remove four screws attaching condensing heat exchanger assembly to primary cell inlet panel. 2. Remove screws attaching primary cells to primary cell inlet panel. 3. Remove main limit and shield from primary cell inlet panel. Note orientation of shield and direction of main limit for reassembly. 4. Remove primary cell inlet panel by lifting panel off condensing heat exchanger collector box. 5. Slide new inlet cell panel over condensing heat exchanger collector box. 6. Attach primary cell inlet panel to primary cells by doing the following: a. Center primary cell inlet panel over primary cell openings. b. Use an awl to align holes and start ALL screws (provided in kit) in primary cells. c. After all screws are started, check position of fiberglass gasket and tighten screws in cells. 7. Install main limit and shield in primary cell inlet panel. A93407 Fig. 2 - Variable-Speed !! sw, o "_--- MOTOR AND SLOWER ASSEMBLY Model in Upflow Orientation NOTE: Visually check location of main limit and shield to ensure shield is not touching primary cells. If shield is touching, short cycling of limit will occur. 8. Reinstall condensing heat exchanger assembly to primary cell inlet panel. Reinstall Inducer Assembly 1. Inspect connector box gasket where inducer housing will mate. NOTE: If gasket is damaged in any way, it nmst be repaired. To repair, apply a small bead of G.E. RTV 162, G.E. 6702, or Dow-Corning RTV 738 to damaged gasket area. Apply sealant releasing agent such as PAM cooking spray or equivalent (nmst not contain corn nor canola oil, halogenated hydrocarbons or aromatic content to prevent inadequate sealing) to inducer housing mating surface. 2. Attach inducer assembly to cell panel by aligning four screws through inducer housing spacers. Tighten screws to secure. 3. Attach collector box pressure switch tube to pressure switch. See tubing diagram of furnace for proper location attachment. 4. If control was removed from furnace with whole cell panel assembly, reconnect inducer motor wire connector at quick-connect. 5. If control was removed from furnace with whole cell panel assembly, reconnect pressure switch wires. Refer to wiring diagram on furnace for proper attachment. Reinstall Burner Enclosure Assembly 1. Position burner enclosure gasket between the burner box and inlet cell panel and secure burner box on inlet cell panel using screws removed earlier. 2. Connect pressure tube to gas valve. 3. Inspect gasket, then install intake housing on burner enclosure. COLD SPOT BAFFLE COUPLING BOX PRIMARY CELL F RIMARY CELL INLET PANEL MAIN LIMIT SHIELD BURNER ENCLOSURE GASKET MAIN LIMI BLOWER SHELF CONDENSING HEAT EXCHANGER CELL REAR PANEL g CONDENSING HEAT EXCHANGER ASSEMBLY PRIMARY CELL OUTLET PANEL SWITCH NOTE: ACTUAL COMPONENT LOCATION DEPENDING ON MODEL & SERIES. BURNER ENCLOSURE AND GASVAVLE MAY VARY INDUCER MOTOR A05128 Fig. 3 - Expanded NOTE: If gasket repair, apply Dow-Corning releasing not is damaged a small RTV corn nor content to enclosure mating surface. 4. Connect canola RTV 162, gasket (i.E. System NOTE: or the lower area. Apply sealant (must inadequate hydrocarbons sealing) to Components To 6702, spray or equivalent oil, halogenated prevent pressure Whole G.E. as PAM cooking aromatic Reinstall in any way, it must be repaired. of 738 to damaged agent such contain bead View of Heat or burner in Upflow When flange must engage Orientation reinstalling condensing of the condensing on the T-tabs heat exchanger heat exchanger in rear blower shelf. (See Fig. 3.) 3. Install three screws to each side of inlet cell panel and into cell panel supports. 4. If previously removed, reinstall control tube to intake housing. Cell Panel to follow Whole install. cell panel this caution may result in personal assembly is located in blower pull wires to flame sensor, HAZARD is heavy. ature switch, gas valve, limit switch, and J-box injury. Get help to lift and compartment hot surface pressure through wires (if present) of furnace, igniter, overtemper- switch(es), inducer blower shelf. whole burner control cell panel assembly with heat exchanger, box, inducer assembly, J-box (if applicable), center (if applicable) through front of furnace. and 9. Reinstall condensate trap where nace casing or blower shelf. NOTE: HAZARD previously 10. Reconnect condensate trap drain tubes. gram on furnace for proper tube location. 11. Connect AND []NIT OPERATION motor, 7. Install J-box. 8. Reattach wires to control center or components. ing diagram on furnace for proper attachment. 1. Install FIRE in casing 5. If control center is located in burner compartment or furnace, reinstall blower motor leads, transformer wires, door Assembly 6. If control INJURY Failure center flange. switch wires, and auxiliary limit switch through blower shelf and grommet. PERSONAL assembly, cell rear panel Ensure field drain to condensate tubes are not kinked See wir- installed fur- See tubing dia- trap. or pinched, as this will affect operation. Failure to follow this warning could iniury, death and / or property damage. DO NOT cut or tear foil occur, repair insulation 2. Secure whole face insulation. two screws on 120 housing. and 140 in personal If cuts or tears with foil tape. cell panel stalling result assembly through sizes) blower 12. Connect 13. Connect to blower housing and two screws shelf by in(four next screws to blower vent pipe by inserting meric (rubber) ing outlet. coupling, combustion-air install screw to secure. used. pipe into coupling, elasto- and then fully into inducer intake pipe to intake housing Do not use RTV unless housand previously 14. Install top filler panel. 15. Install gas supply pipe to gas valve using backup wrench. NOTE:Usepropane gas-resistant pipedope toprevent gasleaks DONOTuseTeflon tape. EXPLOSION ANDFIREHAZARD Failure tofollowthiswarning couldresult inpersonal injury, death and/or property damage. Forupflowordownflow applications, gasvalveknob orswitch must befacing forward ortipped totheUP position. 16.Connect fieldpower supply toJ-box. 17.Install blower access panel. 18.Turnongasandelectrical supplies tofurnace. 19.Check forgasleaks. EXPLOSION ANDFIREHAZARD Failure to followthiswarning couldresultin personal injury,death, and/or property damage. Nevertestforgasleakswithanopenflame.Usea commercially available soap solution made specifically for thedetection ofleaks tocheck allconnections. 20.Check furnace operation through twocycles. 21.Check forcondensate leaks. 22.Replace furnace door. !! Copyright 2009 CA( Manufacturer _BDP * 7310 W. Morris St. * Indianapolis, reserves the right to change, IN 46231 at any time, specifications and designs Edition Date: 09_09 Printed in U.S.A. without notice and without obligations. 6 Catalo_l Replaces: No: IIK320720-004 IIK320720 003
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 6 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Sat Mar 06 04:20:02 2010 Author : Title : Subject :EXIF Metadata provided by EXIF.tools