Banner Engineering RGAGE50 QT50R and SA1T family sensors User Manual

Banner Engineering Corporation QT50R and SA1T family sensors

User Manual

DatasheetRadar-Based Sensors for Detecon of Moving and Staonary Targets• FMCW (true-presence) radar detects moving and staonary objects• Higher sensivity and longer range• Adjustable sensing eld — ignores objects beyond setpoint• Easy setup and conguraon of range, sensivity, and output with simple DIP switches• Sensing funcons are unaected by wind, falling rain or snow, fog, humidity, airtemperatures, or light• Sensor operates in Industrial, Scienc, and Medical (ISM) telecommunicaon band• Rugged IP67 housing withstands harsh environmentsProtected by US patentsCAUTION: Make No Modicaons to this ProductAny modicaons to this product not expressly approved by Banner Engineering could void the user's authority tooperate the product. Contact Banner Engineering for more informaon.WARNING: Not To Be Used for Personnel ProteconNever use this device as a sensing device for personnel protecon. Doing so could lead to serious injury or death.This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safetyapplicaons. A sensor failure or malfuncon can cause either an energized or de-energized sensor outputcondion.ModelsModel Versions 1MaximumRange Connecon Supply Voltage Telecom Approval2OutputQT50R-US24 m (78 ) 5-wire 2 m(6.5 )Integral cable12 to 30 V dc Telecom approved for US, Canada and BrazilBipolar NPN/PNPDIP-switch-selectableN.O. or N.C.QT50R-EU Telecom approved for Europe, UK, Australia,New Zealand, China, and JapanQT50R-KR 12 to 24 V dc Telecom approved for South KoreaQT50R-TW 12 to 30 V dc Telecom approved for TaiwanQT50R-SG Telecom approved for Singapore1Cabled models only are listed. For integral 5-pin Euro-style (M12) quick-disconnect ng, add sux "Q" to the model number (e.g., QT50R-xx-AFHQ). QD models require a mang cordset; see Quick Disconnect (QD) Cordsets on page 6.2For addional countries, contact Banner Engineering.R-GAGE® QT50R SensorOriginal Document162359 Rev.  XXXXXXXXXXXXX162359
OverviewThe R-GAGE sensor emits a well-dened beam of high-frequency radio wavesfrom an internal antenna. Some of this emied energy reects back to thereceiving antenna. Signal processing electronics in the sensor determine thedistance from the sensor to the object based on the me delay of the returnsignal. The sensor can be congured (via DIP switches) to sense objects up toa specic distance, ignoring objects beyond this distance (also calledbackground suppression).DX YSetpointFigure 1. R-GAGE SetpointFigure 2. R-Gage Features1. Power LED: Green (power ON)2. Signal Strength LED: Red (ashes inproporon to the signal strength)3. Output LEDs: Yellow (output energized); Red(conguraon)Access the DIP switches behind the threaded cap onthe sensor back (not shown)R-GAGE setpoint distances, minimum and maximum (sensor will detect objects up to setpoint and ignore objects beyond the setpoint)EU, KR Models TW, US ModelsX Minimum setpoint distance 2 m (6.6 ) 3.5 m (11.5 )Y Maximum setpoint distance 24 m (78.7 ) 24 m (78.7 )D Dead Zone3Sensor ConguraonThe sensing zone distance, sensivity, and output conguraon can be selected via the DIP switches on the back of the sensor. Use theincluded spanner to open the screw-o cover on the back of the sensor and access the DIP switches.Important: Tighten the DIP switch cover a full quarter turn aer contact to maintain the waterght seal.DIP Switch FunconsSwitch Funcon1, 2, 3 Sensing distance (detects objects from sensor face to this point)4, 5 Sensivity (higher sensivity sees weaker objects and has a larger beam paern)6 Normally open/normally closed output funconality7, 8 Response SpeedDIP switch 1 is on the le and DIP switch 8 is on the right.Distance Sengs* Default sengs3Typical dead zone: 0.4 m (1.3 ) for moving and 1.0 m (3.3 ) for staonary targets, but varies with target reecvityR-GAGE® QT50R Sensor2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 162359 Rev.
Switch 1 Switch 2 Switch 3 DistanceEU, KR Models TW, US Models0 0 0 2 m (6.6 ) 3.5 m (11.5 )0 0 1 3 m (9.8 ) 4 m (13.1 )0 1 0 4 m (13.1 ) 5 m (16.4 )0 1 1 6 m (19.7 ) 6 m (19.7 )1* 0* 0* 8 m (26.2 ) 8 m (26.2 )1 0 1 12 m (39.4 ) 12 m (39.4 )1 1 0 16 m (52.5 ) 16 m (52.5 )1 1 1 24 m (78.7 ) 24 m (78.7 )Note: Highest sensivity is achieved only if sensing distance is 8 m (26.2 ) or less.Note: Near-eld sensivity boost is enabled when set to 4 m (13.1 ) or less.Sensivity SeleconSwitch 4 Switch 5 Sensivity0* 0* 4 (Highest)0 1 3 (High)1 0 2 (Medium)1 1 1 (Low)* Default sengsNote: Use the sensivity selecon to ignore unwanted weak reecons within the eld of view, and not to narrowthe beam width. Narrow-beam R-GAGE sensor models are available.Output Conguraon* Default sengsSwitch 6 NO/NC0* NO1 NCResponse SpeedSwitch 7 Switch 8 On Total (ms) O Total (ms) Total (ms)0 0 30 70 1000* 1* 50 300 3501 0 30 1000 10301 1 120 6000 6120* Default sengsR-GAGE® QT50R SensorP/N 162359 Rev. www.bannerengineering.com - Tel: +1-763-544-3164 3
SpecicaonsRangeThe sensor is able to detect a proper object (see Detectable Objects) from 1 to24 m (3.3 to 78.7 ), depending on targetDetectable ObjectsObjects containing metal, water, or similar high-dielectric materialsOperang PrincipleFrequency modulated connuous-wave (FMCW) radarOperang FrequencyTW Models: 24.075–24.175 GHz, ISM Band US, EU, KR, SG Models: 24.050-24.250 GHz, ISM BandMaximum Output PowerERP: 3.3 mW, 5 dBmEIRP: 100 mW, 20 dBmSupply Voltage12 to 30 V dc, less than 100 mA, exclusive of loadFor KR models: 12 to 24 V dc, less than 100 mA exclusive of loadSupply Protecon CircuitryProtected against reverse polarity and transient overvoltagesDelay at Power-upLess than 2 secondsOutput ConguraonBipolar NPN/PNP output, 150mA; DIP switch 6 selects N.O. (default) or N.C.operaonOutput ProteconProtected against short circuit condionsResponse TimeDIP switches 7 & 8 select ON/OFF response meIndicatorsPower LED: Green (power ON)Signal Strength LED: Red, ashes in proporon to signal strength. Steady on at4x excess gain. Only indicates signal amplitude, not target distance.Output LEDs: Yellow (output energized) / Red (conguraon)See Figure 2 on page 2AdjustmentsDIP-switch-congurable sensing distance, sensivity, response me, andoutput conguraonConstruconHousing: ABS/polycarbonateLightpipes: AcrylicAccess Cap: PolyesterOperang Temperature−40 °C to +65 °C (−40 °F to +149 °F)Environmental RangIEC IP67ConneconsIntegral 5-wire 2 m (6.5 ) cable or M12 Euro-style QD ng. QD modelsrequire a mang cordsetCercaonsETSI/EN 300 440FCC part 15RSS-210ANATEL Category IICMIIT Category GARIB STD T-73KC mark - MSIP/RRANCCIDA Singaporefor others, contact Banner EngineeringCountry of Origin: USAFCC ID: UE3QT50RUS—This device complies with Part 15 of the FCC Rules. Operaon is subject to the following two condions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.FCC ID: UE3RGAGE50—This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.IC: 7044A-QT50RCA—This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Cet appareil est conforme aux CNR exempts de licence d'Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes:(1) Ce dispositif ne peut causer des interférences; et(2) Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent entraîner un mauvais fonctionnement de l'appareil.Este equipamento opera em caráter secundário, isto é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo po e não pode causar interferência a sistemas operando em caráter primário.SRD24-IO3B24100.2TR0.1 South Korea Class A CercaonA 급 기기 ( 업무용 방송통신기자재 )이기기는 업무용 (A 급 ) 으로 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기바라며 , 가정외의 지역에서 사용하는 것을 목적으로 합니다 .R-GAGE® QT50R Sensor4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 162359 Rev.
Beam PaernTypical Beam Paern (with BRTR-CC20E Radar Target, Radar Cross Secon = 50m2)Typical Beam Paern (with 4 dierent targets) at highest sensivity levelLe-Right Beam Paern20 m10 m0 m10 m20 m0 10 m 20 m 30 m 40 mSensitivity 11234Sensitivity 4DistanceLe-Right Beam Paern20 m10 m0 m10 m20 m0 10 m 20 m 30 m 40 mTarget 4Target 11234Distance1–4: Indicates sensivity level 1: Weak Object (Radar cross secon = 0.25 m2)2: Car (Radar cross secon = 3 m2)3: Large Truck (Radar cross secon = 50 m2)4: Passenger Train (Radar cross secon = 300 m2)Note: The eecve beam paern depends on the sensivity level and target properes.Dimensions38.1 mm (1.50")46.1 mm (1.82")R45.0 mm (R1.77")66.0 mm (2.60")33.0 mm (1.30")37.0 mm (1.46")74.1 mm (2.92")50.8 mm (2.00")50.8 mm (2.00") 19.7 mm (0.78")37.0 mm (1.46")M30 X 1.5 ISO-6g4X Ø4.4 mm (Ø 0.17")34.2 mm(1.35")WindowsThe R-GAGE sensor can be placed behind a glass or a plasc window, but the conguraon must be tested and the distance from thesensor to the window must be determined and controlled prior to installaon. There is typically a 20% signal reducon when the sensoris placed behind a window.Polycarbonate at 4 mm thickness performs well in most situaons, but the performance depends on ller materials. Thinner (1 to 3 mm)windows have high reecon. The amount of reecon depends on the material, thickness, and distance from the sensor to thewindow.R-GAGE® QT50R SensorP/N 162359 Rev.  www.bannerengineering.com - Tel: +1-763-544-3164 5
Locate the sensor in a posion of minimum reecon from the window, which will repeat every 6.1 mm of distance between the sensorand the window. The posions of maximum reecon from the window repeat between the minimums, and decrease in eect unl thewindow is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distancewithout issue.Addionally, the face of the window should be protected from owing water and ice by use of a ow diverter or hood directly above thewindow. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typicallynot an issue. However, a thick, connuous surface of water or ice directly on the face of the window can be detected as a dielectricboundary.Wiringshield (QD cordset)3124512-30V dcLoad 1Load 2+–Wiring Key:1 = Brown2 = White3 = Blue4 = Black5 = Gray (Do not connect)Note: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc common.Shielded cordsets are recommended for all QD models.AccessoriesQuick Disconnect (QD) Cordsets5-Pin Threaded M12/Euro-Style Cordsets—with ShieldModel Length Style Dimensions Pinout (Female)MQDEC2-506 1.83 m (6 )Straight44 Typ.ø 14.5M12 x 1234151 = Brown2 = White3 = Blue4 = Black5 = GrayMQDEC2-515 4.57 m (15 )MQDEC2-530 9.14 m (30 )MQDEC2-550 15.2 m (50 )MQDEC2-506RA 1.83 m (6 )Right-Angle32 Typ.[1.26"]30 Typ.[1.18"]ø 14.5 [0.57"]M12 x 1MQDEC2-515RA 4.57 m (15 )MQDEC2-530RA 9.14 m (30 )MQDEC2-550RA 15.2 m (50 )Note: Pin 5 is not used.Mounng BracketsAll measurements are in mmR-GAGE® QT50R Sensor6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 162359 Rev.
SMB30SC•Swivel bracket with 30 mmmounng hole for sensor•Black reinforced thermoplascpolyester•Stainless steel mounng andswivel locking hardwareincluded675829BAHole center spacing: A=ø 50.8Hole size: A=ø 7.0, B=ø 30.0SMB30MM•12-ga. stainless steel bracketwith curved mounng slots forversale orientaon• Clearance for M6 (¼ in)hardware•Mounng hole for 30 mmsensor7057ABC57Hole center spacing: A = 51, A to B = 25.4Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1Weather DeectorQT50RCK•Required if the R-GAGE is exposed to rain or snow• Prevents buildup of water or ice from interfering with sensorperformanceBanner Engineering Corp. Limited WarrantyBanner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair orreplace, free of charge, any product of its manufacture which, at the me it is returned to the factory, is found to have been defecve during the warranty period. This warranty does not coverdamage or liability for misuse, abuse, or the improper applicaon or installaon of the Banner product.THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.This Warranty is exclusive and limited to repair or, at the discreon of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANYOTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCTDEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligaons or liabilies relang to any product previouslymanufactured by Banner Engineering Corp. Any misuse, abuse, or improper applicaon or installaon of this product or use of the product for personal protecon applicaons when theproduct is idened as not intended for such purposes will void the product warranty. Any modicaons to this product without prior express approval by Banner Engineering Corp will void theproduct warranes. All specicaons published in this document are subject to change; Banner reserves the right to modify product specicaons or update documentaon at any me.Specicaons and product informaon in English supersede that which is provided in any other language. For the most recent version of any documentaon, refer to: www.bannerengineering.com.R-GAGE® QT50R Sensor© Banner Engineering Corp. All rights reserved