Banner Engineering RGAGE50 QT50R and SA1T family sensors User Manual

Banner Engineering Corporation QT50R and SA1T family sensors

User Manual

Download: Banner Engineering RGAGE50 QT50R and SA1T family sensors User Manual
Mirror Download [FCC.gov]Banner Engineering RGAGE50 QT50R and SA1T family sensors User Manual
Document ID4102455
Application IDDCSOpveJ9DG0U6vE2By2WQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize175.71kB (2196350 bits)
Date Submitted2018-12-11 00:00:00
Date Available2018-12-11 00:00:00
Creation Date2017-10-23 16:13:10
Producing SoftwareAntenna House PDF Output Library 6.2.726 (Windows (x64))
Document Lastmod2018-10-23 08:54:23
Document TitleUser Manual
Document CreatorAH XSL Formatter V6.2 MR12 for Windows (x64) : 6.2.14.22278 (2015/10/30 10:00JST)

R-GAGE® QT50R Sensor
Datasheet
Radar-Based Sensors for Detection of Moving and Stationary Targets
•
•
•
•
•
•
•
FMCW (true-presence) radar detects moving and stationary objects
Higher sensitivity and longer range
Adjustable sensing field — ignores objects beyond setpoint
Easy setup and configuration of range, sensitivity, and output with simple DIP switches
Sensing functions are unaffected by wind, falling rain or snow, fog, humidity, air
temperatures, or light
Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunication band
Rugged IP67 housing withstands harsh environments
Protected by US patents
CAUTION: Make No Modifications to this Product
Any modifications to this product not expressly approved by Banner Engineering could void the user's authority to
operate the product. Contact Banner Engineering for more information.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output
condition.
Models
Model Versions 1
Maximum
Range
Connection
Supply Voltage Telecom Approval2
QT50R-US
Telecom approved for US, Canada and Brazil
QT50R-EU
QT50R-KR
QT50R-TW
QT50R-SG
Output
24 m (78 ft)
5-wire 2 m
(6.5 ft)
Integral cable
12 to 30 V dc
Telecom approved for Europe, UK, Australia,
New Zealand, China, and Japan
12 to 24 V dc
Telecom approved for South Korea
12 to 30 V dc
Telecom approved for Taiwan
Bipolar NPN/PNP
DIP-switch-selectable
N.O. or N.C.
Telecom approved for Singapore
1 Cabled models only are listed. For integral 5-pin Euro-style (M12) quick-disconnect fitting, add suffix "Q" to the model number (e.g., QT50R-xxAFHQ). QD models require a mating cordset; see Quick Disconnect (QD) Cordsets on page 6.
2 For additional countries, contact Banner Engineering.
Original Document
162359 Rev.
XXXXXXXXXXXXX
162359
R-GAGE® QT50R Sensor
Overview
The R-GAGE sensor emits a well-defined beam of high-frequency radio waves
from an internal antenna. Some of this emitted energy reflects back to the
receiving antenna. Signal processing electronics in the sensor determine the
distance from the sensor to the object based on the time delay of the return
signal. The sensor can be configured (via DIP switches) to sense objects up to
a specific distance, ignoring objects beyond this distance (also called
background suppression).
Setpoint
Figure 2. R-Gage Features
Figure 1. R-GAGE Setpoint
1. Power LED: Green (power ON)
2. Signal Strength LED: Red (flashes in
proportion to the signal strength)
3. Output LEDs: Yellow (output energized); Red
(configuration)
Access the DIP switches behind the threaded cap on
the sensor back (not shown)
R-GAGE setpoint distances, minimum and maximum (sensor will detect objects up to setpoint and ignore objects beyond the setpoint)
EU, KR Models
TW, US Models
Minimum setpoint distance
2 m (6.6 ft)
3.5 m (11.5 ft)
Maximum setpoint distance
24 m (78.7 ft)
24 m (78.7 ft)
Dead
Zone3
Sensor Configuration
The sensing zone distance, sensitivity, and output configuration can be selected via the DIP switches on the back of the sensor. Use the
included spanner to open the screw-off cover on the back of the sensor and access the DIP switches.
Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight seal.
DIP Switch Functions
Switch
Function
1, 2, 3
Sensing distance (detects objects from sensor face to this point)
4, 5
7, 8
Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern)
Normally open/normally closed output functionality
Response Speed
DIP switch 1 is on the left and DIP switch 8 is on the right.
Distance Settings
* Default settings
Typical dead zone: 0.4 m (1.3 ft) for moving and 1.0 m (3.3 ft) for stationary targets, but varies with target reflectivity
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 162359 Rev.
R-GAGE® QT50R Sensor
Switch 1
Switch 2
Switch 3
Distance
EU, KR Models
TW, US Models
2 m (6.6 ft)
3.5 m (11.5 ft)
3 m (9.8 ft)
4 m (13.1 ft)
4 m (13.1 ft)
5 m (16.4 ft)
6 m (19.7 ft)
6 m (19.7 ft)
1*
0*
0*
8 m (26.2 ft)
8 m (26.2 ft)
12 m (39.4 ft)
12 m (39.4 ft)
16 m (52.5 ft)
16 m (52.5 ft)
24 m (78.7 ft)
24 m (78.7 ft)
Note: Highest sensitivity is achieved only if sensing distance is 8 m (26.2 ft) or less.
Note: Near-field sensitivity boost is enabled when set to 4 m (13.1 ft) or less.
Sensitivity Selection
Switch 4
Switch 5
Sensitivity
0*
0*
4 (Highest)
3 (High)
2 (Medium)
1 (Low)
* Default settings
Note: Use the sensitivity selection to ignore unwanted weak reflections within the field of view, and not to narrow
the beam width. Narrow-beam R-GAGE sensor models are available.
Output Configuration
* Default settings
Switch 6
NO/NC
0*
NO
NC
Response Speed
Switch 7
Switch 8
On Total (ms)
Off Total (ms)
Total (ms)
30
70
100
0*
1*
50
300
350
30
1000
1030
120
6000
6120
* Default settings
P/N 162359 Rev.
www.bannerengineering.com - Tel: +1-763-544-3164
R-GAGE® QT50R Sensor
Specifications
Range
The sensor is able to detect a proper object (see Detectable Objects) from 1 to
24 m (3.3 to 78.7 ft), depending on target
Detectable Objects
Objects containing metal, water, or similar high-dielectric materials
Operating Principle
Frequency modulated continuous-wave (FMCW) radar
Indicators
Power LED: Green (power ON)
Signal Strength LED: Red, flashes in proportion to signal strength. Steady on at
4x excess gain. Only indicates signal amplitude, not target distance.
Output LEDs: Yellow (output energized) / Red (configuration)
See Figure 2 on page 2
Adjustments
DIP-switch-configurable sensing distance, sensitivity, response time, and
output configuration
Operating Frequency
TW Models: 24.075–24.175 GHz, ISM Band US,
EU, KR, SG Models: 24.050-24.250 GHz, ISM Band
Construction
Housing: ABS/polycarbonate
Lightpipes: Acrylic
Access Cap: Polyester
Maximum Output Power
ERP: 3.3 mW, 5 dBm
EIRP: 100 mW, 20 dBm
Supply Voltage
12 to 30 V dc, less than 100 mA, exclusive of load
For KR models: 12 to 24 V dc, less than 100 mA exclusive of load
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Delay at Power-up
Less than 2 seconds
Operating Temperature
−40 °C to +65 °C (−40 °F to +149 °F)
Environmental Rating
IEC IP67
Connections
Integral 5-wire 2 m (6.5 ft) cable or M12 Euro-style QD fitting. QD models
require a mating cordset
Certifications
Output Configuration
Bipolar NPN/PNP output, 150mA; DIP switch 6 selects N.O. (default) or N.C.
operation
Output Protection
Protected against short circuit conditions
Response Time
DIP switches 7 & 8 select ON/OFF response time
ETSI/EN 300 440
FCC part 15
RSS-210
ANATEL Category II
CMIIT Category G
ARIB STD T-73
KC mark - MSIP/RRA
NCC
IDA Singapore
for others, contact Banner Engineering
Country of Origin: USA
FCC ID: UE3QT50RUS—This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
FCC ID: UE3RGAGE50—This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
IC: 7044A-QT50RCA—This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
Cet appareil est conforme aux CNR exempts de licence d'Industrie Canada. Son fonctionnement est soumis aux deux conditions
suivantes:(1) Ce dispositif ne peut causer des interférences; et(2) Ce dispositif doit accepter toute interférence, y compris les
interférences qui peuvent entraîner un mauvais fonctionnement de l'appareil.
Este equipamento opera em caráter secundário, isto é, não tem direito à proteção
contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode
causar interferência a sistemas operando em caráter primário.
SRD24-IO3B24100.2TR0.1 South Korea Class A Certification
A 급 기기 ( 업무용 방송통신기자재 )
이 기기는 업무용 (A 급 ) 으로 전자파적합기기로
서 판매자 또는 사용자는 이 점을 주의하시기
바라며 , 가정외의 지역에서 사용하는 것을 목
적으로 합니다 .
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 162359 Rev.
R-GAGE® QT50R Sensor
Beam Pattern
Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50
m2)
Typical Beam Pattern (with 4 different targets) at highest sensitivity level
Left-Right Beam Pattern
Left-Right Beam Pattern
20 m
20 m
Sensitivity 4
Sensitivity 1
10 m
Target 4
Target 1
10 m
0m
0m
10 m
10 m
20 m
20 m
10 m
20 m
30 m
40 m
Distance
10 m
20 m
30 m
40 m
Distance
1: Weak Object (Radar cross section = 0.25 m2)
2: Car (Radar cross section = 3 m2)
3: Large Truck (Radar cross section = 50 m2)
4: Passenger Train (Radar cross section = 300 m2)
1–4: Indicates sensitivity level
Note: The effective beam pattern depends on the sensitivity level and target properties.
Dimensions
74.1 mm
(2.92")
46.1 mm
(1.82")
37.0 mm
(1.46")
38.1 mm
(1.50")
4X Ø4.4 mm
(Ø 0.17")
33.0 mm
(1.30")
50.8 mm
(2.00")
66.0 mm
(2.60")
R45.0 mm
(R1.77")
34.2 mm
(1.35")
19.7 mm
(0.78")
37.0 mm
(1.46")
M30 X 1.5
ISO-6g
50.8 mm
(2.00")
Windows
The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the
sensor to the window must be determined and controlled prior to installation. There is typically a 20% signal reduction when the sensor
is placed behind a window.
Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials. Thinner (1 to 3 mm)
windows have high reflection. The amount of reflection depends on the material, thickness, and distance from the sensor to the
window.
P/N 162359 Rev.
www.bannerengineering.com - Tel: +1-763-544-3164
R-GAGE® QT50R Sensor
Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance between the sensor
and the window. The positions of maximum reflection from the window repeat between the minimums, and decrease in effect until the
window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distance
without issue.
Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the
window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typically
not an issue. However, a thick, continuous surface of water or ice directly on the face of the window can be detected as a dielectric
boundary.
Wiring
Wiring Key:
12-30V dc
–
Load 1
1 = Brown
2 = White
3 = Blue
Load 2
4 = Black
5 = Gray (Do not connect)
shield (QD cordset)
Note: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc common.
Shielded cordsets are recommended for all QD models.
Accessories
Quick Disconnect (QD) Cordsets
5-Pin Threaded M12/Euro-Style Cordsets—with Shield
Model
Length
MQDEC2-506
1.83 m (6 ft)
MQDEC2-515
4.57 m (15 ft)
MQDEC2-530
9.14 m (30 ft)
MQDEC2-550
15.2 m (50 ft)
MQDEC2-506RA
1.83 m (6 ft)
MQDEC2-515RA
4.57 m (15 ft)
MQDEC2-530RA
9.14 m (30 ft)
Style
Dimensions
44 Typ.
Straight
M12 x 1
ø 14.5
15.2 m (50 ft)
32 Typ.
[1.26"]
30 Typ.
[1.18"]
Right-Angle
MQDEC2-550RA
Pinout (Female)
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
M12 x 1
ø 14.5 [0.57"]
Note: Pin 5 is not used.
Mounting Brackets
All measurements are in mm
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 162359 Rev.
R-GAGE® QT50R Sensor
SMB30SC
• Swivel bracket with 30 mm
mounting hole for sensor
• Black reinforced thermoplastic
polyester
• Stainless steel mounting and
swivel locking hardware
included
67
58
29
SMB30MM
• 12-ga. stainless steel bracket
with curved mounting slots for
versatile orientation
• Clearance for M6 (¼ in)
hardware
• Mounting hole for 30 mm
sensor
Hole center spacing: A=ø 50.8
Hole size: A=ø 7.0, B=ø 30.0
57
70
57
Hole center spacing: A = 51, A to B = 25.4
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
Weather Deflector
QT50RCK
• Required if the R-GAGE is exposed to rain or snow
• Prevents buildup of water or ice from interfering with sensor
performance
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover
damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY
OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT
DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the
product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time.
Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
© Banner Engineering Corp. All rights reserved

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Create Date                     : 2017:10:23 16:13:10-06:00
Creator Tool                    : AH XSL Formatter V6.2 MR12 for Windows (x64) : 6.2.14.22278 (2015/10/30 10:00JST)
Modify Date                     : 2018:10:23 08:54:23-05:00
Metadata Date                   : 2018:10:23 08:54:23-05:00
Producer                        : Antenna House PDF Output Library 6.2.726 (Windows (x64))
Trapped                         : False
Format                          : application/pdf
Document ID                     : uuid:ce099e51-d1f0-40d8-a503-b425d518fdcf
Instance ID                     : uuid:d7e84515-318e-4869-9378-c8901872f943
Page Count                      : 7
Creator                         : AH XSL Formatter V6.2 MR12 for Windows (x64) : 6.2.14.22278 (2015/10/30 10:00JST)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UE3RGAGE50

Navigation menu