Barco N V ST150B01 Panel PC User Manual

Barco N.V. Panel PC

User manual

ST-150B
User guide
K5903075/01AD
16/01/2014
Barco nv
President Kennedypark 35, 8500 Kortrijk, Belgium
Phone: +32 56.23.32.11
Fax: +32 56.26.22.62
Support: www.barco.com/esupport
Visit us at the web: www.barco.com
PrintedinBelgium
Table of contents
TABLE OF CONTENTS
1. Welcome! .......................................................................................... 3
1.1 About the product ............................................................................................. 3
1.2 Whats in the box.............................................................................................. 3
2. Parts, controls and connectors ............................................................... 5
2.1 System setup.................................................................................................. 5
3. System installation .............................................................................. 11
3.1 Mounting .......................................................................................................11
3.2 Installation .....................................................................................................11
3.3 Installation of HDD, SSD (optional) .........................................................................12
3.4 Running the BIOS setup program...........................................................................12
3.5 Installing system software....................................................................................12
3.6 Installing the drivers ..........................................................................................13
4. System operation ................................................................................ 15
4.1 Frequently used functions....................................................................................15
5. Maintenance ....................................................................................... 17
5.1 Cleaning instructions .........................................................................................17
6. Important information ........................................................................... 19
6.1 Safety information.............................................................................................19
6.2 Environmental information ...................................................................................21
6.3 Regulatory compliance information .........................................................................23
6.4 EMC notice ....................................................................................................23
6.5 Explanation of symbols.......................................................................................27
6.6 Legal disclaimer...............................................................................................29
6.7 Technical specications ......................................................................................29
K5903075 ST-150B 16/01/2014 1
Table of contents
2K5903075 ST-150B 16/01/2014
1. Welcome!
1. WELCOME!
1.1 About the product
Smart Terminal
The ST-150B is a multimedia Intel® Atom processor-based computer that is designed to serve as a Point
of Care (POC) and Point of Information terminal (POI) within healthcare applications. It is a PC based
system with 15" color TFT LCD display, Gigabit Ethernet, multi-COM port and USB 2.0 interfaces and
High Denition Audio codec.
The ST-150B Smart Terminal™ is as compact and user-friendly as a notebook computer. This simple,
complete and highly integrated multimedia system lets system integrators easily build the ST-150B Smart
Terminal™ into their applications.
The device is not intended to be used in patient monitoring, diagnosis,treatment,alle-
viation or prevention of diseases, injuries and handicaps.
CAUTION:Read all the important safety information before installing and operating your
ST-150B. Please refer to the dedicated chapter in this user guide.
1.2 What’s in the box
Overview
Your ST-150B comes with:
PSU & Power cord — USA, European, UK types (where applicable)
Handset & Coiled Cable (where applicable)
Accessories for the ST-150B (where applicable)
Keep your original packaging. It is designed for this terminal and is the ideal protection during transport
and storage.
WARNING:To prevent electric shock, DO NOT remove covers. No user serviceable
parts inside, refer servicing to qualied personnel.
K5903075 ST-150B 16/01/2014 3
1. Welcome!
4K5903075 ST-150B 16/01/2014
2. Parts, controls and connectors
2. PARTS, CONTROLS AND
CONNECTORS
2.1 System setup
Become familiar
Before you set up the ST-150B, take a moment to become familiar with the locations and purposes of the
controls, drives, connections and ports, which are illustrated in the gures below.
Front
When you place the ST-150B upright on the desktop, its front panel appears as shown in the gure below.
1
2
Image 2-1
Front view of the ST-150B
1Membrane which contains functions: Power, Volume Up/Down, Backward/Forward, Stop,
Play/Pause and Channel Up/Down
2Webcam
K5903075 ST-150B 16/01/2014 5
2. Parts, controls and connectors
Left, Right
When you look at the left side of the ST-150B, you will see a handset, tted to the left docking port. At the
right side of the terminal, you will see an MSR reader, tted to the right docking port.
1 2
Image 2-2
Side views of the ST-150B
1Handset (optional)
2MSR Reader (Mag Stripe Reader) (optional)
Bottom
On the bottom side of the ST-150B you will ndaSmartCardReaderandanI/Oarea,asshowninthe
gure below.
1 2
Image 2-3
Bottom view of the ST-150B
1SCR (Smart Card Reader)
2I/O area bottom
6K5903075 ST-150B 16/01/2014
2. Parts, controls and connectors
Rear
On the rear of the ST-150B you will nd the two removable access doors located left and right of the
terminal. The right-hand cover provides access to the system DDR memory and a mini PCIe slot, and the
left-hand cover provides access to the HDD, as shown in the gure below.
123
Image 2-4
Rear view of the ST-150B
1Access door to HDD*
2I/O area rear
3Access door to System DDR memory and mini PCIe slot*
CAUTION:* The access doors may only be opened by qualied service personal, no
user serviceable parts inside.
K5903075 ST-150B 16/01/2014 7
2. Parts, controls and connectors
IO areas
There are two I/O areas in the ST-150B; one is at the back and the other one is at the bottom. The gures
below indicate the various ports of these two areas.
1 2 3 4 5
Image 2-5
I/O ports at the back of the ST-150B
18P8C handset connector +Fin Service Call Connector
2RJ 45 Shielded Gigabit Ethernet Connector
3USB Connector
4USB Connector
5Power Connector
1 2 3 4 5
Image 2-6
I/O ports at the bottom of the ST-150B
1USB Connector (2x)
2Microphone Jack
3Headset Jack (2x)
4DVI-I Connector
526-Way MDR Connector (for optional remote control or a Service Call device)
The RJ9 socket is for handset connection only.
8K5903075 ST-150B 16/01/2014
2. Parts, controls and connectors
Label location
2
1
3
4
Image 2-7
Label location
1Intel® label
2FCC label WiFi module
3FCC label Bluetooth
4Rating label
K5903075 ST-150B 16/01/2014 9
2. Parts, controls and connectors
10 K5903075 ST-150B 16/01/2014
3. System installation
3. SYSTEM INSTALLATION
3.1 Mounting
Fixing the terminal to a mounting solution
The terminal is foreseen from a mounting anchor that can be used for different mounting solutions (arms,
desk stands, ...).
To install the terminal, please follow the detailed mounting instructions in the user guide, which is delivered
with the mounting solution you have chosen for your terminal.
3.2 Installation
Connecting the power cable
Always handle the power cable by holding the plug end only. Follow these steps:
1. Connect the male end of the power supply DIN cable to the DC inlet of the ST-150B, see gure below.
2. Connect the male plug of the power supply to an electrical outlet.
Image 3-1
Connecting the power cable
Connecting USB keyboard and mouse
1. Connect the keyboard and mouse to the USB ports located on the bottom cover of the ST-150B, see
gure below.
Image 3-2
Connecting the keyboard and mouse
Switching on the power
1. Switch on the ST-150B via the power switch on the front cover, see gure below.
K5903075 ST-150B 16/01/2014 11
3. System installation
Image 3-3
Switching on the power
3.3 Installation of HDD, SSD (optional)
CAUTION:The installation of the optional HDD and/or SSD drive should be carried out
by a professional technician. Only UL-certied hard disks may be installed!
Please contact a service technician or your reseller if you need this service.
3.4 Running the BIOS setup program
BIOS setup
Your ST-150B is likely to have been properly set up and congured by your dealer prior to delivery. If
you still nd it necessary to use the BIOS (Basic Input-Output System) setup program to change system
conguration information please contact Barco for support.
The settings you specify with the setup program are recorded in a special area of memory called CMOS
RAM. This memory is backed up by a battery so that it will not be erased when you turn off or reset
the system. Whenever you turn on the power, the system reads the settings stored in CMOS RAM and
compares them to the equipment check conducted during the power on self-test (POST). If an error occurs,
an error message will be displayed on screen, and you will be prompted to run the setup program.
3.5 Installing system software
Setup and installation instructions
Recent releases of operating systems from major vendors include setup programs which load automati-
cally and guide you through hard disk preparation and operating system installation. The guidelines below
will help you determine the steps necessary to install your operating system on the ST-150B. If required,
insert your operating system’s installation or setup disc into a portable optical drive and plug into one of
the ST-150B USB ports.
Some distributors and system integrators may have already pre-installed system soft-
ware prior to shipment of your ST-150B.
If you are presented with a setup/installation screen then carefully follow the instructions. The setup pro-
gram will guide you through preparation of your hard drive, and installation of the operating system.
12 K5903075 ST-150B 16/01/2014
3. System installation
3.6 Installing the drivers
Drivers
After installing the system software, you will be able to install the necessary drivers. All the ST-150B
drivers and updates can be obtained from Barco.
The drivers and utilities used for the ST-150B are subject to change without notice. If
in doubt, check with your local Barco ofce or contact our application engineers for the
latest information regarding drivers and utilities.
K5903075 ST-150B 16/01/2014 13
3. System installation
14 K5903075 ST-150B 16/01/2014
4. System operation
4. SYSTEM OPERATION
4.1 Frequently used functions
Using the Smart Card Reader (SCR)
1. Insert the card rmly into the allocated slot with the chip facing towards the front of the terminal. (See
gure below). The Smart Card will be recognized by the terminal.
Image 4-1
Using the Smart Card Reader (SCR)
Using the RFID Reader
1. Present the card to the reader by tapping and holding it brieyont
o the clearly reader-marked area until
the card is read.
Image 4-2
Using the RFID reader
Using the MagStripe Reader (MSR)
1. Insert the card rmly into the allocated slot with the chip facing towards the side of the terminal. (See
gure below). The Magnetic Stripe Card will be recognized by the terminal.
K5903075 ST-150B 16/01/2014 15
4. System operation
Image 4-3
Using the Magnetic Stripe Reader (MSR)
16 K5903075 ST-150B 16/01/2014
5. Maintenance
5. MAINTENANCE
This device does not require any scheduled maintenance activities. In case of a defect,
return the device to a Barco approved maintenance organization. In any case of doubts,
contact the Barco Healthcare Division
5.1 Cleaning instructions
Cleaning is no mandatory maintenance activity for the ST-150B.
During normal use, the ST-150B surfaces may become soiled. If you should like to clean
them, follow the detailed cleaning instructions in the below paragraph.
To clean the terminal
Examples of approved cleaning agents:
Green tinctured soap and Enzymatic detergents
• Mediwipes
Vernacare wipes
1. Prepare agent per manufacturer’s instructions or hospital protocol.
2. Wipe the ST-150B with a clean cloth that has been moistened in the cleaning solution.
3. Wipe thoroughly with a clean cloth.
The ST-150B’s surfaces are resistant to the following cleaning materials:
Isopropyl alcohol
Ammonia-based glass cleaners
• Turpentine
Mineral spirits
CAUTION:Do not immerse or rinse the ST-150B and its peripherals. If you acciden-
tally spill liquid on the device, disconnect the unit from the power source. Contact your
Biomed regarding the continued safety of the unit before placing it back in operation.
Do not spray cleaning agent on the chassis.
Do not use disinfectants that contain phenol. Do not autoclave or clean the ST-150B or
its peripherals with strong aromatic, chlorinated, ketone, ether, or ester solvents, sharp
tools or abrasives. Never immerse electrical connectors in water or other liquids.
In environments where specic chemicals or cleaning agents are required to be used,
please contact Barco.
K5903075 ST-150B 16/01/2014 17
5. Maintenance
18 K5903075 ST-150B 16/01/2014
6. Important information
6. IMPORTANT INFORMATION
6.1 Safety information
General recommendations
Read the safety and operating instructions before operating the device.
Retain safety and operating instructions for future reference.
Adhere to all warnings on the device and in the operating instructions manual.
Follow all instructions for operation and use.
Electrical Shock or Fire Hazard
To prevent electric shock or re hazard, do not remove cover.
No serviceable parts inside. Refer servicing to qualied personnel.
Do not expose this apparatus to rain or moisture.
Safety instructions
Do not modify this equipment without authorization of the manufacturer.
The equipment must be powered using the delivered medical approved DC power supply only.
The medical approved DC power supply must be powered by the AC mains voltage (protective earth
terminal).
To avoid the risk of electric shock, this equipment must only be connected to a supply
mains with protective earth.
Make sure the voltage of the power source is correct before connecting the equipment to the power
outlet.
Position the power cord so that it is not a hazard. Do not place anything over the power cord.
If the equipment is out of use for an extended period, make sure to disconnect it from the power source
to avoid damage in the event of a power surge.
Earth the ST-150B by connecting the protective earth pin to a grounded outlet by means of the supplied
wire.
If one of the following situations arises, ensure you get the equipment checked by service personnel:
a) The power cord or plug is damaged.
b) The equipment has been exposed to moisture.
c) The equipment is not functioning properly, or you cannot get it to work according to the user manual.
d) The equipment has been dropped and damaged.
e) The equipment has obvious signs of breakage.
To disconnect the device: Remove the rear power supply power connection.
If your computer is losing time or the BIOS conguration resets to default settings, the battery most
likely has no power.
Do not replace the battery yourself. Please contact a qualied technician or your supplier of the
ST-150B. The ST-150B is provided with a battery-powered real-time clock circuit. There is a danger
of leakage or explosion if the battery is incorrectly replaced. Replace only with same or equivalent
type recommended by the manufacturer. Discard used batteries according to the manufacturers in-
structions.
K5903075 ST-150B 16/01/2014 19
6. Important information
Warning: if the equipment is not used for a long time, please make sure that the battery is removed
from the equipment.
Place the terminal on a stable surface that can support the weight of at least 4 terminals or hang from
a reliable structure during installation. Dropping the equipment is likely to cause serious injury to a
child or adult, and serious damage to the equipment.
Improper installation of VESA mounting can result in serious personal injury! Use a VESA mounting
solution that can support a weight of at least 10kg. VESA mount installation should be carried out by a
professional technician. Please contact the service technician or your reseller if you need this service.
Keep this equipment away from excessive humidity.
Do not pour any liquid into the vents on the terminal. This may cause re or electrical shock.
The vents on the enclosure are for air convection and protect the equipment from overheating. Do not
cover the vents.
When installing the terminal in a cupboard or another closed location, heed the necessary space be-
tween the set and the sides of the cupboard.
Do not leave this equipment in an uncontrolled environment where the storage temperature is below
-20 °C or above 60°C. This may damage the equipment.
Equipment not suitable for use in the presence of a ammable anesthetic mixture with air or with
oxygen or nitrous oxide.
For more information about recycling of this product, please contact your local city ofce, your munic-
ipal waste disposal service or the shop where you purchased the product.
This equipment is not intended to be used in life support systems, operating rooms or for diagnostic
purposes.
External connections to model ST-150B (I/O, LAN, etc) shall be in compliance with the requirements
for medical electrical systems as stated in chapter 16 of the standard for medical electrical equipment
IEC 60601-1: 2005.
Accessory equipment connected to the analog and digital interfaces must be in compliance with the
respective nationally harmonized IEC standards (i.e. IEC 60601 for data processing equipment). If in
doubt, consult the technical services department or your local representative.
Type of protection (electrical):
Display with external power supply: Class I equipment.
Degree of safety (ammable anesthetic mixture):
Equipment not suitable for use in the presence of a ammable anesthetic mixture with air or with oxygen
or nitrous oxide.
Non-patient care equipment
Equipment primarily for use in a health care facility that is intended for use where contact with a patient
is unlikely (no applied part).
The equipment may not be used with life support equipment.
The user is not supposed to touch SIP/SOPs and the patient at the same time.
Power connection – Equipment with external 19 VDC power supply
Power requirements: The equipment must be powered using the delivered medical approved 19 VDC
() power supply.
The medical approved DC ( ) power supply must be powered by the AC mains voltage.
The power supply is specied as a part of the ME equipment or combination is specied as a ME
system.
To avoid the risk of electric shock, this equipment must only be connected to a supply mains with
protective earth.
The equipment should be installed near an easily accessible outlet.
The equipment is intended for continuous operation.
20 K5903075 ST-150B 16/01/2014
6. Important information
Transient over-voltage
If the device is not used for a long time, disconnect it from the AC inlet to avoid damage by transient
over-voltage.
To fully disengage the power to the device, please disconnect the power cord from the AC inlet.
Power cords:
Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 250 V
min., provided with a hospital-grade type plug 5-15P conguration for 120V application, or 6-15P for
240V application.
Do not overload wall outlets and extension cords as this may result in re or electric shock.
Mains lead protection (U.S.: Power cord): Power cords should be routed so that they are not likely to
be walked upon or pinched by items placed upon or against them, paying particular attention to cords
at plugs and receptacles.
The power supply cord should be replaced by the designated operator only at all time.
Use a power cord that matches the voltage of the power outlet, which has been approved and complies
with the safety standard of your particular country.
Ventilation
Do not cover or block any ventilation openings in the cover of the set. When installing the device in a
cupboard or another closed location, heed the necessary space between the set and the sides of the
cupboard.
This apparatus conforms to:
ANSI/AAMI ES 60601-1:2005; CAN/CSA-C22.2 No.60601-1:08; FCC-Class A; CE
6.2 Environmental information
Disposal Information
Waste Electrical and Electronic Equipment
This symbol on the product indicates that, under the European Directive 2012/19/EU governing
waste from electrical and electronic equipment, this product must not be disposed of with other municipal
waste. Please dispose of your waste equipment by handing it over to a designated collection point for the
recycling of waste electrical and electronic equipment. To prevent possible harm to the environment or
human health from uncontrolled waste disposal, please separate these items from other types of waste
and recycle them responsibly to promote the sustainable reuse of material resources.
For more information about recycling of this product, please contact your local city ofce or your municipal
waste disposal service.
For details, please visit the Barco website at: http://www.barco.com/en/AboutBarco/weee
Disposal of batteries in the product
This product contains batteries covered by the Directive 2006/66/EC which must be collected and
disposed of separately from municipal waste.
If the battery contains more than the specied values of lead (Pb), mercury (Hg) or cadmium (Cd), these
chemical symbols will appear below the crossed-out wheeled bin symbol.
K5903075 ST-150B 16/01/2014 21
6. Important information
By participating in separate collection of batteries, you will help to ensure proper disposal and to prevent
potential negative effects on the environment and human health.
Turkey RoHS compliance
Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur.
[Republic of Turkey: In conformity with the WEEE Regulation]
中国大RoHS
Chinese Mainland RoHS
根据中国大子信息染控制管理法》(也称中国大RoHS, 以下部分列出了Barco
中可能包含的有毒和/或有害物的名称和含量。中国RoHS指令包含在中国信息产业MCV准:
子信息品中有毒物的限量要求中。
According to the “China Administration on Control of Pollution Caused by Electronic Information Products”
(Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or
hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in
the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of
toxic substances in Electronic Information Products”.
零件(名称)
Component name
有毒有害物或元素
Hazardous substances and elements
Pb
Hg
Cd
Cr6+
溴联
PBB
二苯
PBDE
印制路配件
Printed Circuit Assemblies
xooo oo
外接(线)
External Cables
xooo oo
线
Internal wiring
oo oo oo
塑胶外壳
Plastic enclosure
oo oo oo
源供
Power Supply Unit
xooo oo
Fan
oo oo oo
文件
Paper Manuals
oo oo oo
盘说
CD manual
oo oo oo
O: 表示有毒有害物件所有均材料中的含量均在 SJ/T 11363-2006 定的限量要求以下.
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for
this part is below the limit requirement in SJ/T11363-2006.
X: 表示有毒有害物至少在部件的某一均材料中的含量超出 SJ/T 11363-2006 定的
限量要求.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous
materials used for this part is above the limit requirement in SJ/T11363-2006
22 K5903075 ST-150B 16/01/2014
6. Important information
在中国大陆销售的相应电子信息品(EIP)都遵照中国大子信息染控制标识要求》
保使用期限(EFUP标签Barco品所采用的EFUP标签阅实例,徽内部的号使用于制
品)基于中国大的《子信息保使用期限通准。
All Electronic Information Products (EIP) that are sold within Chinese Mainland must comply with the
“Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked with
the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses
(please refer to the photo) is based on the “Standard of Electronic Information Products Environmental
Friendly Use Period” of Chinese Mainland.
10
6.3 Regulatory compliance information
Indications for use
The ST-150B is not intended to be used in patient monitoring, diagnosis, treatment, alleviation or preven-
tion of diseases, injuries and handicaps.
RF exposure warning
This equipment must be installed and operated in accordance with provided instructions and the an-
tenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm
from all persons and must not be co-located or operating in conjunction with any other antenna or trans-
mitter. End-users and installers must be provided with antenna installation instructions and transmitter
operating conditions for satisfying RF exposure compliance.
FCC class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-
tion manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Changes or modications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
6.4 EMC notice
General information
No specic requirement on the use of external cables or other accessories except power supply.
K5903075 ST-150B 16/01/2014 23
6. Important information
With the installation of the device, use only the delivered power supply or a spare part provided by the
legal manufacturer. Using another can result in a decrease of the immunity level of the device.
Electromagnetic emissions
The ST-150B is intended for use in the electromagnetic environment specied below. The customer or
the user of the ST-150B should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment –
Guidance
RF emissions
CISPR 11
Group 1 The ST-150B uses RF energy
only for its internal function.
Therefore, its RF emissions are
very low and are not likely to
cause any interference in nearby
electronic equipment.
RF emissions
CISPR 11
Class A
Harmonic emissions
IEC 61000-3-2
Class D
Voltage uctuations/ icker
emissions
IEC 61000-3-3
Complies
The ST-150B is suitable for use
in all establishments, including
domestic establishments and
those directly connected to the
public low-voltage power supply
network that supplies buildings
used for domestic purposes.
This ST-150B complies with appropriate medical EMC standards on emissions to, and interference from
surrounding equipment. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
Interference can be determined by turning the equipment off and on.
If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding
equipment, the user is encouraged to try to correct the interference by one or more of the following mea-
sures:
Reorient or relocate the receiving antenna or equipment.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced technician for help.
Electromagnetic immunity
The ST-150B is intended for use in the electromagnetic environment specied below. The customer or
the user of the ST-150B should assure that it is used in such an environment.
Immunity test IEC 60601
Test levels
Compliance level Electromagnetic
environment –
guidance
Electrostatic discharge
(ESD)
IEC 61000-4-2
± 6kV contact
±8kVair
± 6kV contact
±8kVair
Floors should be wood,
concrete or ceramic tile.
If oors are covered with
synthetic material, the
relative humidity should
be at least 30%
Electrical fast
transient/burst
IEC 61000-4-4
± 2kV for power supply
lines
± 1kV for input/ output
lines
± 2kV for power supply
lines
± 1kV for input/ output
lines
Mains power quality
should be that of a typical
commercial or hospital
environment
24 K5903075 ST-150B 16/01/2014
6. Important information
Immunity test IEC 60601
Test levels
Compliance level Electromagnetic
environment –
guidance
Surge
IEC61000-4-5
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
± 1 kV line(s) to line(s)
±2kVline(s)toearth
Mains power quality
should be that of a typical
commercial or hospital
environment
Voltage dips, short
interruptions and voltage
variations on power
supply input lines
IEC 61000-4-11
<5%U
T1(> 95% dip in
UT) for 0.5 cycle
40% UT(60%dipinU
T)
for 5 cycles
70% UT(30%dipinU
T)
for 25 cycles
<5%U
T(>95% dip in
UT) for 5s
<5%U
T(> 95% dip in
UT) for 0.5 cycle
40% UT(60% dip in UT)
for 5 cycles
70% UT(30% dip in UT)
for 25 cycles
<5%U
T(>95% dip in
UT)for5s
Mains power quality
should by that of a typical
commercial or hospital
environment. If the
user of the ST-150B
requires continued
operation during power
mains interruptions, it is
recommended that the
ST-150B be powered
from an uninterruptible
power supply or a battery.
Power frequency (50/60
Hz) magnetic eld
IEC 61000-4-8
3A/m Not applicable Power frequency
magnetic elds should
be at levels characteristic
of a typical location in
a typical commercial or
hospital environment.
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3Vrms
150 kHz to 80 MHz
3V/m
80 MHz to 2.5 GHz
3V
3V/m
Portable and mobile
RF communications
equipment should be
used no closer to any
part of the ST-150B,
including cables, than
the recommended
separation distance
calculated from the
equation applicable
to the frequency
of the transmitter.
Recommended
separation distance
d=1.2P
d=1.2P80 MHz to 800
MHz
d=2.3P800 MHz to 2.5
Ghz
Where P is the maximum
output power rating
of the transmitter in
watts (W) according
to the transmitter
manufacturer and d
is the recommended
separation distance in
meters (m).
Field strengths from
xed RF transmitters,
as determined by an
1. is the a.c. mains voltage prior to application of the test level.
K5903075 ST-150B 16/01/2014 25
6. Important information
Immunity test IEC 60601
Test levels
Compliance level Electromagnetic
environment –
guidance
electromagnetic site
survey,2should be less
than the compliance
level in each frequency
range.3
Interference may occur in
the vicinity of equipment
marked with symbol:
At 80 MHz and 800 MHz, the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation is af-
fected by absorption and reection from structures, objects and people.
Recommended separation distance
The ST-150B is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer of the user of the ST-150B can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications equipment (trans-
mitters) and the ST-150B as recommended below, according to the maximum output power of the com-
munications equipment.
Separation distance according to frequency of transmitter
Rated maximum output
power of transmitter 4
W
150kHz to 80MHz
d=1.2P
80MHz to 800MHz
d=1.2P
800MHz to 2.5GHz
d=2.3P
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100121223
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
2. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur
radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the
location in which the ST-150B is used exceeds the applicable RF compliance level above, the ST-150B should be observed to verify
normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating
the ST-150B.
3. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than3V/m.
4. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be
estimated using the equation applicable to the frequency of the transmitter. Where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
26 K5903075 ST-150B 16/01/2014
6. Important information
These guidelines may not apply in all situations. Electromagnetic propagation is af-
fected by absorption and reection form structures, object and people.
6.5 Explanation of symbols
Symbols on the device
On the device or power supply, you may nd the following symbols (nonrestrictive list):
Indicates the device meets the requirements of the applicable EC directives.
Indicates compliance with Part 15 of the FCC rules (Class A or Class B)
Indicates the device is approved according to the UL Recognition regulations
Indicates the device is approved according to the UL Demko regulations
Indicates the device is approved according to the CCC regulations
Indicates the device is approved according to the VCCI regulations
Indicates the device is approved according to the KC regulations
Indicates the device is approved according to the BSMI regulations
Indicates the USB connectors on the device
Indicates the DisplayPort connectors on the device
Indicates the manufacturing date
Indicates the temperature limitations5for the device to safely operate within specs.
5. Values for xx and yy can be found in the technical specifications paragraph.
K5903075 ST-150B 16/01/2014 27
6. Important information
Indicates the device serial no
Warning: dangerous voltage
Caution
Consult the operating instructions
Indicates this device must not be thrown in the trash but must be recycled,
according to the European WEEE (Waste Electrical and Electronic Equipment)
directive
Indicates Direct Current (DC)
Indicates Alternating Current (AC)
Stand-by
Symbols on the box
On the box of the device, you may nd the following symbols (nonrestrictive list):
Indicates a device that can be broken or damaged if not handled carefully when
being stored.
Indicates a device that needs to be protected from moisture when being stored.
Indicates the storage direction of the box. The box must be transported, handled
and stored in such a way that the arrows always point upwards.
15
or
n
Indicates the maximum number of identical boxes which may be stacked on each
other, where “n” is the limiting number.
20 - 30 Kg
Indicates that the box should be carried with two persons.
Indicates that the box should not be cut with a knife, a cutter or any other sharp
object.
-20 °C
+60 °C
xx
yy
Indicates the temperature limits6to which the device can be safely exposed when
being stored.
28 K5903075 ST-150B 16/01/2014
6. Important information
85 %
5 %
x
yy Indicates the range6of humidity to which the device can be safely exposed when
being stored.
106 kPa
50 kPa
xx
yyy Indicates the range6of atmospheric pressure to which the device can be safely
exposed when being stored.
6.6 Legal disclaimer
Disclaimer notice
Although every attempt has been made to achieve technical accuracy in this document, we assume no
responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable
documentation possible; if you discover errors, please let us know.
Barco software products are the property of Barco. They are distributed under copyright by Barco N.V. or
Barco, Inc., for use only under the specic terms of a software license agreement between Barco N.V. or
Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any
form, is authorized.
The specications of Barco products are subject to change without notice.
Trademarks
All trademarks and registered trademarks are property of their respective owners.
Copyright notice
This document is copyrighted. All rights are reserved. Neither this document, nor any part of it, may
be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including
photocopying, taping or information storage and retrieval systems - without written permission of Barco.
© 2014 Barco N.V. All rights reserved.
6.7 Technical specications
Technical specications for the ST-150B
Display LED, 15" SXGA (1024 x 768)
Processor Intel Atom Cedar Trail D2550 – 1.86 Ghz
System chip set Intel NM10
BIOS AMI 16M-bit SPI UFEI BIOS
RTC battery CR2032
Storage Optional 2.5” HDD or SSD (Standard - no storage installed)
Required rating: 5Vdc, max 2A
HDD drive 320 GB (optional)
SSD drive 8, 16, or 32 GB (optional)
6. Values for xx and yy can be found in the technical specifications paragraph.
K5903075 ST-150B 16/01/2014 29
6. Important information
System memory DDR3 1066
2or4GB
Operating system Linux
Windows® XP Embedded
Windows® XP Professional for Embedded Systems
Windows® 7 Embedded
Connectivity LAN (x1)
USB 2.0 (x4)
Headphone jack (x2)
Microphone jack (x1)
Handset connector
DVI out
Programmable GPIO
Service Call (optional)
User interface 5-wire resistive touch-screen
On screen keyboard
Membrane keypad
On/Off switch
LED call warning lights
Webcam Integrated, with privacy shutter
HD720P
Audio 2 off 2 Watt integral speakers
Internal microphone
Warning / ring tones
Medical Environment
Considerations
Antibacterial coating
Fanless cooling
Certications EN/UL60601, FCC-Class A, CE??????????????????
Power requirements 19V DC, 4.74A
Device is intended to be supplied with a PSU with rated output of 19V,
4.74A,
Dimensions (mm) 384 x 354 x 70 (without handset, MSR)
Weight 4.0 kg
Internal options
Smart Card Reader (SCR)
Combined SCR and RFID
reader
WiFi Mini PCe 802.11b/g/n Wireless LAN Module
Bluetooth USB Bluetooth Module
External options
Analogue handset
30 K5903075 ST-150B 16/01/2014
6. Important information
MagStripe Reader (MSR) (right side only)
Wired remote (RIMO)
Headphone hanger
Operating temperature 0°C to 40°C
Storage & transport
temperature
-20°C to 60°C
Operating humidity 20% - 90% (non-condensing)
Storage & transport humidity 10% - 80% (non-condensing)
Operating atmospheric
pressure
50 - 106 kPa
Storage and transport
atmospheric pressure
50 - 106 kPa