Barco N V ST150B01 Panel PC User Manual
Barco N.V. Panel PC
User manual
ST-150B User guide K5903075/01AD 16/01/2014 Barco nv President Kennedypark 35, 8500 Kortrijk, Belgium Phone: +32 56.23.32.11 Fax: +32 56.26.22.62 Support: www.barco.com/esupport Visit us at the web: www.barco.com Printed in Belgium Table of contents TABLE OF CONTENTS 1. Welcome! .......................................................................................... 3 1.1 1.2 About the product .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 3 What’s in the box. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 3 2. Parts, controls and connectors ............................................................... 5 2.1 System setup . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 5 3. System installation .............................................................................. 11 3.1 3.2 3.3 3.4 3.5 3.6 Mounting .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 11 Installation .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 11 Installation of HDD, SSD (optional) .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 12 Running the BIOS setup program .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 12 Installing system software. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 12 Installing the drivers . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 13 4. System operation ................................................................................ 15 4.1 Frequently used functions. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 15 5. Maintenance ....................................................................................... 17 5.1 Cleaning instructions .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 17 6. Important information ........................................................................... 19 6.1 6.2 6.3 6.4 6.5 6.6 6.7 Safety information.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 19 Environmental information .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 21 Regulatory compliance information .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 23 EMC notice . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 23 Explanation of symbols .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 27 Legal disclaimer .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 29 Technical specifications . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . 29 K5903075 ST-150B 16/01/2014 Table of contents K5903075 ST-150B 16/01/2014 1. Welcome! 1. WELCOME! 1.1 About the product Smart Terminal The ST-150B is a multimedia Intel® Atom processor-based computer that is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. It is a PC based system with 15" color TFT LCD display, Gigabit Ethernet, multi-COM port and USB 2.0 interfaces and High Definition Audio codec. The ST-150B Smart Terminal™ is as compact and user-friendly as a notebook computer. This simple, complete and highly integrated multimedia system lets system integrators easily build the ST-150B Smart Terminal™ into their applications. The device is not intended to be used in patient monitoring, diagnosis, treatment, alleviation or prevention of diseases, injuries and handicaps. CAUTION: Read all the important safety information before installing and operating your ST-150B. Please refer to the dedicated chapter in this user guide. 1.2 What’s in the box Overview Your ST-150B comes with: • • • PSU & Power cord — USA, European, UK types (where applicable) Handset & Coiled Cable (where applicable) Accessories for the ST-150B (where applicable) Keep your original packaging. It is designed for this terminal and is the ideal protection during transport and storage. WARNING: To prevent electric shock, DO NOT remove covers. No user serviceable parts inside, refer servicing to qualified personnel. K5903075 ST-150B 16/01/2014 1. Welcome! K5903075 ST-150B 16/01/2014 2. Parts, controls and connectors 2. PARTS, CONTROLS AND CONNECTORS 2.1 System setup Become familiar Before you set up the ST-150B, take a moment to become familiar with the locations and purposes of the controls, drives, connections and ports, which are illustrated in the figures below. Front When you place the ST-150B upright on the desktop, its front panel appears as shown in the figure below. Image 2-1 Front view of the ST-150B Membrane which contains functions: Power, Volume Up/Down, Backward/Forward, Stop, Play/Pause and Channel Up/Down Webcam K5903075 ST-150B 16/01/2014 2. Parts, controls and connectors Left, Right When you look at the left side of the ST-150B, you will see a handset, fitted to the left docking port. At the right side of the terminal, you will see an MSR reader, fitted to the right docking port. Image 2-2 Side views of the ST-150B Handset (optional) MSR Reader (Mag Stripe Reader) (optional) Bottom On the bottom side of the ST-150B you will find a Smart Card Reader and an I/O area, as shown in the figure below. Image 2-3 Bottom view of the ST-150B SCR (Smart Card Reader) I/O area bottom K5903075 ST-150B 16/01/2014 2. Parts, controls and connectors Rear On the rear of the ST-150B you will find the two removable access doors located left and right of the terminal. The right-hand cover provides access to the system DDR memory and a mini PCIe slot, and the left-hand cover provides access to the HDD, as shown in the figure below. Image 2-4 Rear view of the ST-150B Access door to HDD* I/O area rear Access door to System DDR memory and mini PCIe slot* CAUTION: * The access doors may only be opened by qualified service personal, no user serviceable parts inside. K5903075 ST-150B 16/01/2014 2. Parts, controls and connectors IO areas There are two I/O areas in the ST-150B; one is at the back and the other one is at the bottom. The figures below indicate the various ports of these two areas. 3 4 Image 2-5 I/O ports at the back of the ST-150B 8P8C handset connector +Fin Service Call Connector RJ 45 Shielded Gigabit Ethernet Connector USB Connector USB Connector Power Connector Image 2-6 I/O ports at the bottom of the ST-150B USB Connector (2x) Microphone Jack Headset Jack (2x) DVI-I Connector 26-Way MDR Connector (for optional remote control or a Service Call device) The RJ9 socket is for handset connection only. K5903075 ST-150B 16/01/2014 2. Parts, controls and connectors Label location Image 2-7 Label location Intel® label FCC label WiFi module FCC label Bluetooth Rating label K5903075 ST-150B 16/01/2014 2. Parts, controls and connectors 10 K5903075 ST-150B 16/01/2014 3. System installation 3. SYSTEM INSTALLATION 3.1 Mounting Fixing the terminal to a mounting solution The terminal is foreseen from a mounting anchor that can be used for different mounting solutions (arms, desk stands, ...). To install the terminal, please follow the detailed mounting instructions in the user guide, which is delivered with the mounting solution you have chosen for your terminal. 3.2 Installation Connecting the power cable Always handle the power cable by holding the plug end only. Follow these steps: 1. Connect the male end of the power supply DIN cable to the DC inlet of the ST-150B, see figure below. 2. Connect the male plug of the power supply to an electrical outlet. Image 3-1 Connecting the power cable Connecting USB keyboard and mouse 1. Connect the keyboard and mouse to the USB ports located on the bottom cover of the ST-150B, see figure below. Image 3-2 Connecting the keyboard and mouse Switching on the power 1. Switch on the ST-150B via the power switch on the front cover, see figure below. K5903075 ST-150B 16/01/2014 11 3. System installation Image 3-3 Switching on the power 3.3 Installation of HDD, SSD (optional) CAUTION: The installation of the optional HDD and/or SSD drive should be carried out by a professional technician. Only UL-certified hard disks may be installed! Please contact a service technician or your reseller if you need this service. 3.4 Running the BIOS setup program BIOS setup Your ST-150B is likely to have been properly set up and configured by your dealer prior to delivery. If you still find it necessary to use the BIOS (Basic Input-Output System) setup program to change system configuration information please contact Barco for support. The settings you specify with the setup program are recorded in a special area of memory called CMOS RAM. This memory is backed up by a battery so that it will not be erased when you turn off or reset the system. Whenever you turn on the power, the system reads the settings stored in CMOS RAM and compares them to the equipment check conducted during the power on self-test (POST). If an error occurs, an error message will be displayed on screen, and you will be prompted to run the setup program. 3.5 Installing system software Setup and installation instructions Recent releases of operating systems from major vendors include setup programs which load automatically and guide you through hard disk preparation and operating system installation. The guidelines below will help you determine the steps necessary to install your operating system on the ST-150B. If required, insert your operating system’s installation or setup disc into a portable optical drive and plug into one of the ST-150B USB ports. Some distributors and system integrators may have already pre-installed system software prior to shipment of your ST-150B. If you are presented with a setup/installation screen then carefully follow the instructions. The setup program will guide you through preparation of your hard drive, and installation of the operating system. 12 K5903075 ST-150B 16/01/2014 3. System installation 3.6 Installing the drivers Drivers After installing the system software, you will be able to install the necessary drivers. All the ST-150B drivers and updates can be obtained from Barco. The drivers and utilities used for the ST-150B are subject to change without notice. If in doubt, check with your local Barco office or contact our application engineers for the latest information regarding drivers and utilities. K5903075 ST-150B 16/01/2014 13 3. System installation 14 K5903075 ST-150B 16/01/2014 4. System operation 4. SYSTEM OPERATION 4.1 Frequently used functions Using the Smart Card Reader (SCR) 1. Insert the card firmly into the allocated slot with the chip facing towards the front of the terminal. (See figure below). The Smart Card will be recognized by the terminal. Image 4-1 Using the Smart Card Reader (SCR) Using the RFID Reader 1. Present the card to the reader by tapping and holding it briefly onto the clearly reader-marked area until the card is read. Image 4-2 Using the RFID reader Using the MagStripe Reader (MSR) 1. Insert the card firmly into the allocated slot with the chip facing towards the side of the terminal. (See figure below). The Magnetic Stripe Card will be recognized by the terminal. K5903075 ST-150B 16/01/2014 15 4. System operation Image 4-3 Using the Magnetic Stripe Reader (MSR) 16 K5903075 ST-150B 16/01/2014 5. Maintenance 5. MAINTENANCE This device does not require any scheduled maintenance activities. In case of a defect, return the device to a Barco approved maintenance organization. In any case of doubts, contact the Barco Healthcare Division 5.1 Cleaning instructions Cleaning is no mandatory maintenance activity for the ST-150B. During normal use, the ST-150B surfaces may become soiled. If you should like to clean them, follow the detailed cleaning instructions in the below paragraph. To clean the terminal Examples of approved cleaning agents: • • • 1. 2. 3. Green tinctured soap and Enzymatic detergents Mediwipes Vernacare wipes Prepare agent per manufacturer’s instructions or hospital protocol. Wipe the ST-150B with a clean cloth that has been moistened in the cleaning solution. Wipe thoroughly with a clean cloth. The ST-150B’s surfaces are resistant to the following cleaning materials: • Isopropyl alcohol • Ammonia-based glass cleaners • Turpentine • Mineral spirits CAUTION: Do not immerse or rinse the ST-150B and its peripherals. If you accidentally spill liquid on the device, disconnect the unit from the power source. Contact your Biomed regarding the continued safety of the unit before placing it back in operation. Do not spray cleaning agent on the chassis. Do not use disinfectants that contain phenol. Do not autoclave or clean the ST-150B or its peripherals with strong aromatic, chlorinated, ketone, ether, or ester solvents, sharp tools or abrasives. Never immerse electrical connectors in water or other liquids. In environments where specific chemicals or cleaning agents are required to be used, please contact Barco. K5903075 ST-150B 16/01/2014 17 5. Maintenance 18 K5903075 ST-150B 16/01/2014 6. Important information 6. IMPORTANT INFORMATION 6.1 Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use. Electrical Shock or Fire Hazard To prevent electric shock or fire hazard, do not remove cover. No serviceable parts inside. Refer servicing to qualified personnel. Do not expose this apparatus to rain or moisture. Safety instructions • • • Do not modify this equipment without authorization of the manufacturer. The equipment must be powered using the delivered medical approved DC power supply only. The medical approved DC power supply must be powered by the AC mains voltage (protective earth terminal). To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. • • • • • • • • Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. Position the power cord so that it is not a hazard. Do not place anything over the power cord. If the equipment is out of use for an extended period, make sure to disconnect it from the power source to avoid damage in the event of a power surge. Earth the ST-150B by connecting the protective earth pin to a grounded outlet by means of the supplied wire. If one of the following situations arises, ensure you get the equipment checked by service personnel: a) The power cord or plug is damaged. b) The equipment has been exposed to moisture. c) The equipment is not functioning properly, or you cannot get it to work according to the user manual. d) The equipment has been dropped and damaged. e) The equipment has obvious signs of breakage. To disconnect the device: Remove the rear power supply power connection. If your computer is losing time or the BIOS configuration resets to default settings, the battery most likely has no power. Do not replace the battery yourself. Please contact a qualified technician or your supplier of the ST-150B. The ST-150B is provided with a battery-powered real-time clock circuit. There is a danger of leakage or explosion if the battery is incorrectly replaced. Replace only with same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions. K5903075 ST-150B 16/01/2014 19 6. Important information • • • • • • • • • • • • Warning: if the equipment is not used for a long time, please make sure that the battery is removed from the equipment. Place the terminal on a stable surface that can support the weight of at least 4 terminals or hang from a reliable structure during installation. Dropping the equipment is likely to cause serious injury to a child or adult, and serious damage to the equipment. Improper installation of VESA mounting can result in serious personal injury! Use a VESA mounting solution that can support a weight of at least 10kg. VESA mount installation should be carried out by a professional technician. Please contact the service technician or your reseller if you need this service. Keep this equipment away from excessive humidity. Do not pour any liquid into the vents on the terminal. This may cause fire or electrical shock. The vents on the enclosure are for air convection and protect the equipment from overheating. Do not cover the vents. When installing the terminal in a cupboard or another closed location, heed the necessary space between the set and the sides of the cupboard. Do not leave this equipment in an uncontrolled environment where the storage temperature is below -20 °C or above 60°C. This may damage the equipment. Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. For more information about recycling of this product, please contact your local city office, your municipal waste disposal service or the shop where you purchased the product. This equipment is not intended to be used in life support systems, operating rooms or for diagnostic purposes. External connections to model ST-150B (I/O, LAN, etc) shall be in compliance with the requirements for medical electrical systems as stated in chapter 16 of the standard for medical electrical equipment IEC 60601-1: 2005. Accessory equipment connected to the analog and digital interfaces must be in compliance with the respective nationally harmonized IEC standards (i.e. IEC 60601 for data processing equipment). If in doubt, consult the technical services department or your local representative. Type of protection (electrical): Display with external power supply: Class I equipment. Degree of safety (flammable anesthetic mixture): Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. Non-patient care equipment • • • Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely (no applied part). The equipment may not be used with life support equipment. The user is not supposed to touch SIP/SOPs and the patient at the same time. Power connection – Equipment with external 19 VDC power supply • • • • • • 20 Power requirements: The equipment must be powered using the delivered medical approved 19 VDC ) power supply. ) power supply must be powered by the AC mains voltage. The medical approved DC ( The power supply is specified as a part of the ME equipment or combination is specified as a ME system. To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. The equipment should be installed near an easily accessible outlet. The equipment is intended for continuous operation. K5903075 ST-150B 16/01/2014 6. Important information Transient over-voltage If the device is not used for a long time, disconnect it from the AC inlet to avoid damage by transient over-voltage. To fully disengage the power to the device, please disconnect the power cord from the AC inlet. Power cords: • • • • • Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 250 V min., provided with a hospital-grade type plug 5-15P configuration for 120V application, or 6-15P for 240V application. Do not overload wall outlets and extension cords as this may result in fire or electric shock. Mains lead protection (U.S.: Power cord): Power cords should be routed so that they are not likely to be walked upon or pinched by items placed upon or against them, paying particular attention to cords at plugs and receptacles. The power supply cord should be replaced by the designated operator only at all time. Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country. Ventilation Do not cover or block any ventilation openings in the cover of the set. When installing the device in a cupboard or another closed location, heed the necessary space between the set and the sides of the cupboard. This apparatus conforms to: ANSI/AAMI ES 60601-1:2005; CAN/CSA-C22.2 No.60601-1:08; FCC-Class A; CE 6.2 Environmental information Disposal Information Waste Electrical and Electronic Equipment This symbol on the product indicates that, under the European Directive 2012/19/EU governing waste from electrical and electronic equipment, this product must not be disposed of with other municipal waste. Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. For more information about recycling of this product, please contact your local city office or your municipal waste disposal service. For details, please visit the Barco website at: http://www.barco.com/en/AboutBarco/weee Disposal of batteries in the product This product contains batteries covered by the Directive 2006/66/EC which must be collected and disposed of separately from municipal waste. If the battery contains more than the specified values of lead (Pb), mercury (Hg) or cadmium (Cd), these chemical symbols will appear below the crossed-out wheeled bin symbol. K5903075 ST-150B 16/01/2014 21 6. Important information By participating in separate collection of batteries, you will help to ensure proper disposal and to prevent potential negative effects on the environment and human health. Turkey RoHS compliance Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur. [Republic of Turkey: In conformity with the WEEE Regulation] 中国大陆 RoHS Chinese Mainland RoHS 根据中国大陆《电子信息产品污染控制管理办法》(也称为中国大陆RoHS), 以下部分列出了Barco产品 中可能包含的有毒和/或有害物质的名称和含量。中国大陆RoHS指令包含在中国信息产业部MCV标准: “电子信息产品中有毒物质的限量要求”中。 According to the “China Administration on Control of Pollution Caused by Electronic Information Products” (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”. 零件项目(名称) 有毒有害物质或元素 Component name Hazardous substances and elements 汞 六价铬 铅 镉 Pb Hg Cd Cr6+ 印制电路配件 多溴联苯 多溴二苯 醚 PBB PBDE Printed Circuit Assemblies 外接电(线)缆 External Cables 內部线路 Internal wiring 塑胶外壳 电源供应器 Power Supply Unit 风扇 Fan 文件说明书 Paper Manuals 光盘说明书 Plastic enclosure CD manual O: 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T 11363-2006 标准规定的限量要求以下. O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T 11363-2006 标准规定的 限量要求. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006 22 K5903075 ST-150B 16/01/2014 6. Important information 在中国大陆销售的相应电子信息产品(EIP)都必须遵照中国大陆《电子信息产品污染控制标识要求》标准 贴上环保使用期限(EFUP)标签。Barco产品所采用的EFUP标签(请参阅实例,徽标内部的编号使用于制 定产品)基于中国大陆的《电子信息产品环保使用期限通则》标准。 All Electronic Information Products (EIP) that are sold within Chinese Mainland must comply with the “Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “Standard of Electronic Information Products Environmental Friendly Use Period” of Chinese Mainland. 10 6.3 Regulatory compliance information Indications for use The ST-150B is not intended to be used in patient monitoring, diagnosis, treatment, alleviation or prevention of diseases, injuries and handicaps. RF exposure warning This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. FCC class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 6.4 EMC notice General information No specific requirement on the use of external cables or other accessories except power supply. K5903075 ST-150B 16/01/2014 23 6. Important information With the installation of the device, use only the delivered power supply or a spare part provided by the legal manufacturer. Using another can result in a decrease of the immunity level of the device. Electromagnetic emissions The ST-150B is intended for use in the electromagnetic environment specified below. The customer or the user of the ST-150B should assure that it is used in such an environment. Emissions test Compliance RF emissions Group 1 Electromagnetic environment – Guidance The ST-150B uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The ST-150B is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. CISPR 11 RF emissions Class A CISPR 11 Harmonic emissions Class D IEC 61000-3-2 Voltage fluctuations/ flicker emissions Complies IEC 61000-3-3 This ST-150B complies with appropriate medical EMC standards on emissions to, and interference from surrounding equipment. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Interference can be determined by turning the equipment off and on. If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding equipment, the user is encouraged to try to correct the interference by one or more of the following measures: • • • • Reorient or relocate the receiving antenna or equipment. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced technician for help. Electromagnetic immunity The ST-150B is intended for use in the electromagnetic environment specified below. The customer or the user of the ST-150B should assure that it is used in such an environment. Immunity test IEC 60601 Compliance level Test levels Electrostatic discharge (ESD) ± 6kV contact ± 6kV contact ± 8kV air ± 8kV air Electrical fast transient/burst ± 2kV for power supply lines ± 2kV for power supply lines IEC 61000-4-4 ± 1kV for input/ output lines ± 1kV for input/ output lines IEC 61000-4-2 24 Electromagnetic environment – guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30% Mains power quality should be that of a typical commercial or hospital environment K5903075 ST-150B 16/01/2014 6. Important information Immunity test Electromagnetic environment – Test levels guidance Mains power quality Surge ± 1 kV line(s) to line(s) ± 1 kV line(s) to line(s) should be that of a typical IEC61000-4-5 ± 2 kV line(s) to earth ± 2 kV line(s) to earth commercial or hospital environment Voltage dips, short < 5% U T 1(> 95% dip in < 5% U T (> 95% dip in Mains power quality interruptions and voltage U T) for 0.5 cycle should by that of a typical U T) for 0.5 cycle variations on power commercial or hospital 40% U T (60% dip in U T) 40% U T (60% dip in U T) supply input lines environment. If the for 5 cycles for 5 cycles user of the ST-150B IEC 61000-4-11 70% U T (30% dip in U T) 70% U T (30% dip in U T) requires continued for 25 cycles for 25 cycles operation during power mains interruptions, it is < 5% U T (>95% dip in < 5% U T (>95% dip in recommended that the U T) for 5s U T) for 5s ST-150B be powered from an uninterruptible power supply or a battery. Not applicable Power frequency (50/60 3 A/m Power frequency Hz) magnetic field magnetic fields should be at levels characteristic IEC 61000-4-8 of a typical location in a typical commercial or hospital environment. 3 Vrms 3V Portable and mobile Conducted RF RF communications 150 kHz to 80 MHz 3 V/ m IEC 61000-4-6 equipment should be 3 V/m used no closer to any Radiated RF part of the ST-150B, 80 MHz to 2.5 GHz IEC 61000-4-3 including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance IEC 60601 Compliance level d = 1.2√P d = 1.2√P 80 MHz to 800 MHz d = 2.3√P 800 MHz to 2.5 Ghz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an 1. is the a.c. mains voltage prior to application of the test level. K5903075 ST-150B 16/01/2014 25 6. Important information Immunity test IEC 60601 Compliance level Test levels Electromagnetic environment – guidance electromagnetic site survey,2 should be less than the compliance level in each frequency range.3 Interference may occur in the vicinity of equipment marked with symbol: At 80 MHz and 800 MHz, the higher frequency range applies. These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Recommended separation distance The ST-150B is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer of the user of the ST-150B can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the ST-150B as recommended below, according to the maximum output power of the communications equipment. Rated maximum output Separation distance according to frequency of transmitter power of transmitter 4 150kHz to 80MHz 80MHz to 800MHz 800MHz to 2.5GHz d=1.2√P d=1.2√P d=2.3√P 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. 2. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the ST-150B is used exceeds the applicable RF compliance level above, the ST-150B should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the ST-150B. 3. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 4. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter. Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. 26 K5903075 ST-150B 16/01/2014 6. Important information These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection form structures, object and people. 6.5 Explanation of symbols Symbols on the device On the device or power supply, you may find the following symbols (nonrestrictive list): Indicates the device meets the requirements of the applicable EC directives. Indicates compliance with Part 15 of the FCC rules (Class A or Class B) Indicates the device is approved according to the UL Recognition regulations Indicates the device is approved according to the UL Demko regulations Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations Indicates the device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the manufacturing date Indicates the temperature limitations5 for the device to safely operate within specs. 5. Values for xx and yy can be found in the technical specifications paragraph. K5903075 ST-150B 16/01/2014 27 6. Important information Indicates the device serial no Warning: dangerous voltage Caution Consult the operating instructions Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive Indicates Direct Current (DC) Indicates Alternating Current (AC) Stand-by Symbols on the box On the box of the device, you may find the following symbols (nonrestrictive list): Indicates a device that can be broken or damaged if not handled carefully when being stored. Indicates a device that needs to be protected from moisture when being stored. Indicates the storage direction of the box. The box must be transported, handled and stored in such a way that the arrows always point upwards. 15 Indicates the maximum number of identical boxes which may be stacked on each other, where “n” is the limiting number. or Indicates that the box should be carried with two persons. 20 - 30 Kg Indicates that the box should not be cut with a knife, a cutter or any other sharp object. yy °C +60 Indicates the temperature limits6 to which the device can be safely exposed when being stored. xx °C -20 28 K5903075 ST-150B 16/01/2014 6. Important information yy % 85 Indicates the range6 of humidity to which the device can be safely exposed when being stored. yyy kPa 106 Indicates the range6of atmospheric pressure to which the device can be safely exposed when being stored. 5x % xx kPa 50 6.6 Legal disclaimer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know. Barco software products are the property of Barco. They are distributed under copyright by Barco N.V. or Barco, Inc., for use only under the specific terms of a software license agreement between Barco N.V. or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized. The specifications of Barco products are subject to change without notice. Trademarks All trademarks and registered trademarks are property of their respective owners. Copyright notice This document is copyrighted. All rights are reserved. Neither this document, nor any part of it, may be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including photocopying, taping or information storage and retrieval systems - without written permission of Barco. © 2014 Barco N.V. All rights reserved. 6.7 Technical specifications Technical specifications for the ST-150B Display LED, 15" SXGA (1024 x 768) Processor Intel Atom Cedar Trail D2550 – 1.86 Ghz System chip set Intel NM10 BIOS AMI 16M-bit SPI UFEI BIOS RTC battery CR2032 Storage Optional 2.5” HDD or SSD (Standard - no storage installed) Required rating: 5Vdc, max 2A HDD drive 320 GB (optional) SSD drive 8, 16, or 32 GB (optional) 6. Values for xx and yy can be found in the technical specifications paragraph. K5903075 ST-150B 16/01/2014 29 6. Important information System memory DDR3 1066 2 or 4 GB Operating system Linux Windows® XP Embedded Windows® XP Professional for Embedded Systems Windows® 7 Embedded Connectivity LAN (x1) USB 2.0 (x4) Headphone jack (x2) Microphone jack (x1) Handset connector DVI out Programmable GPIO Service Call (optional) User interface 5-wire resistive touch-screen On screen keyboard Membrane keypad On/Off switch LED call warning lights Webcam Integrated, with privacy shutter HD720P Audio 2 off 2 Watt integral speakers Internal microphone Warning / ring tones Medical Environment Considerations Antibacterial coating Certifications EN/UL60601, FCC-Class A, CE?????????????????? Power requirements 19V DC, 4.74A Fanless cooling Device is intended to be supplied with a PSU with rated output of 19V, 4.74A, Dimensions (mm) 384 x 354 x 70 (without handset, MSR) Weight 4.0 kg Internal options Smart Card Reader (SCR) √ Combined SCR and RFID reader √ WiFi Mini PCe 802.11b/g/n Wireless LAN Module Bluetooth USB Bluetooth Module External options Analogue handset 30 √ K5903075 ST-150B 16/01/2014 6. Important information MagStripe Reader (MSR) √ (right side only) Wired remote (RIMO) √ Headphone hanger √ Operating temperature 0°C to 40°C Storage & transport temperature -20°C to 60°C Operating humidity 20% - 90% (non-condensing) Storage & transport humidity 10% - 80% (non-condensing) Operating atmospheric pressure 50 - 106 kPa Storage and transport atmospheric pressure 50 - 106 kPa K5903075 ST-150B 16/01/2014 31
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2014:01:17 09:59:38+01:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2014:01:17 09:59:38+01:00 Format : application/pdf Creator : G_KUU_TELIMA Title : Print Preview - C:\Temp\.aptcache\ae26o3hk/tf26o8m1 Document ID : uuid:85ad83d4-448b-4918-a16b-6a0c98a62a55 Instance ID : uuid:b83013d3-77a8-42b2-8a39-c8c165a8f8c5 Page Count : 33 Author : G_KUU_TELIMAEXIF Metadata provided by EXIF.tools