Blue Tower Communications TRANSPONDITV9 AMR TRANSMITTER User Manual 72006002 IM 0A
Blue Tower Communications Ltd AMR TRANSMITTER 72006002 IM 0A
USER MANUAL
Installation Instructions DataSource915 Description DataSource915 attaches to the following water meter registers: • Single pulse, • Master Meter Dual-Pulse, • Electronic encoded AMCO Scancoder, • Electronic encoded (ECR), • Electronic encoded Neptune / Schlumberger ARB V, • Electronic encoded ProRead/AutoDetect/E-CoderTM registers.* 8. NOTE: Max reading (pulse) = 16,777,215 Max reading (encoder) = 9,999,999 - left most digits are dropped. If appropriate check that encoder status is reported as 0. Encoder error codes are shown in the Encoder Status table below. Error Codes Tamper *With E-Coder registers DataSource915 will read register ID and reading only. Single pulse mode allows tamper readings of 1 through 63 which indicates a count of the tamper wire disconnections. The value should be recorded at the time of connection and any subsequent increments should be investigated. DataSource915 sends meter data via radio frequency (RF) signal to a receiving unit; HandTrackIT®, FastTrackIT® or CellTrackIT®. Dual-Pulse mode does not allow tamper detection because all wires are used to count pulses. Required Tools & Equipment Encoder Status The following items are recommended for proper DataSource915 installation: • 3M® Type UY2 gel-filled splice connectors and crimping pliers. • Computer running Windows XP®, 2000®, 98® or NT®. • ConFigIT® device (Mod Strike 14 or higher) and ConFigIT software version 6.5.07 or higher. • ConFigIT cable, part number 330-190-10 (Lemo) or 320-300-10 (9-pin Dtype). • 4 AA batteries or power cable. • HandTrackIT, FastTrackIT, or CellTrackIT receiver with connecting cable. The encoders will display the following codes: Error Code Description 64 No communication from register 65 Open wheel in register 66 Shorted wheel in register 68 Undefined data error from register Leak Error Code 128 Description Leak Flag Mounting Instructions Mount DataSource915 upright facing the direction of the receiver. Avoid placing DataSource915 on any metal walls or large metal objects. Wire Connections Configuration & Installation Procedure 1. 2. 3. 4. 5. 6. 7. Connect DataSource915 to the meter register using 3M Type UY2 gel-filled splice connectors and gel cap crimping pliers. If the default settings (see ‘Factory Default Settings’ section) are suitable for the installation then: • DataSource915 can be activated without ConFigIT by using a small bar or horseshoe magnet. Ensure that the magnet is held vertically over the center of DataSource915 just below the stripe. If the default settings need to be changed, use the ConFigIT device and software: • After performing as READ, select the register required from the pull down list. • To use DataSource915 with ProRead, AutoDetect or E-Coder register, set meter interface mode to ‘AutoDetect’. • To use ID printed on the side of DataSource915 case, select ‘Use current ID’ button. • To enter new ID, select ‘Programmed by User’ button and enter ID in the cell below button. • Set leak detection threshold to required value. • Turn on DataSource915 by setting Transmit Interval (default setting is every 5 seconds) to 5 or 10 secs for FastTrackIt, 10 secs or greater for HandTrackIt. The transmit interval for CellTrackIt operation depends on the required sample rate. Ensure that the MIF wire terminations at the meter are waterproofed in accordance with the Meter manufactures installation procedures. Mount DataSource915 as described in “Mounting Instructions” section above. Verify that the signal is received with the appropriate receiving device from the desired location. Verify that the reading corresponds to the visual indication on the meter register. 123 123 Single Pulse Meters Manufacturer Model Wire 1 Pulse Wire 2 Ground Wire 3 Tamper AMCO/ ABB PSM-T Green Blue Blue AMCO/ ABB Pulsar Red Black Black Master Meter Single-Pulser Black Green Green Badger® RTR 3-wire Green Red Black Badger DSI-IL & RTR 2-wire Red Black Black MetronFarnier Spectrum Red Green Green Dual Pulse Meters Red Green Black DataSource915 monitors both meter switches and will increment the counter after both have been closed in sequence. Blue Tower Communications Inc www.bluetowercomms.com US Office - 201 Shannon Oaks Circle, Suite 200, Cary, NC 27511 Tel +1 919-654-7352 © 2009 Blue Tower Communications Inc. The information contained herein is the property of Blue Tower Communications Inc and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. All other company names, brand names, and product names are the property of their respective holder(s). P/N 72006002 IM Rev 0A Page 1 of 2 Installation Instructions DataSource915 Encoders Scancoder Green ECR Red Black Green Compatible with Hersey® Meters (Translator), MetronFarnier, Sensus/Invensys® and others. ARB V Black Green Red ProRead/ AutoDetect Black Green Red Black Red Factory Default Settings DataSource915 is provided with the following default settings: DataSource915 Interface ID Source Utility Code Pulse DataSource915 ID 09 Warnings & Precautions Warning: Changes or modifications to product not expressly approved by Blue Tower Communications Inc could void the user’s authority to operate the equipment. See FCC information below. This sheet provides instruction needed to successfully connect, configure and read DataSource915 for the water meters listed above in the description section. This sheet is merely a supplement to training in the operation of the Blue Tower DataStream AMR system. For training information, contact Blue Tower Communications Inc directly. FCC Information This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Blue Tower Communications Inc www.bluetowercomms.com US Office - 201 Shannon Oaks Circle, Suite 200, Cary, NC 27511 Tel +1 919-654-7352 © 2009 Blue Tower Communications Inc. The information contained herein is the property of Blue Tower Communications Inc and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. All other company names, brand names, and product names are the property of their respective holder(s). P/N 72006002 IM Rev 0A Page 2 of 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Producer : GPL Ghostscript 8.15 Create Date : 2009:03:03 10:36:31 Modify Date : 2009:03:03 10:36:31 Title : Microsoft Word - 72006002_IM_0A.doc Creator : PScript5.dll Version 5.2.2 Author : PETER WHITEEXIF Metadata provided by EXIF.tools