-1-Content1 Product Feature................................................................ 21.1 General Description................................................ 21.2 Camera Overview..................................................... 21.3 ShootingInformation Display.............................31.4 Product Feature........................................................ 52Cautions............................................................................. 63Quick Start........................................................................73.1 TF card and SIM card..............................................73.2Batteryandpower adapter...................................73.3Quick start................................................................... 84Advanced Operations................................................. 124.1 Mount the camera...................................................124.2Three camera statuses.......................................... 124.3Change camera settings via controlpanel.... 134.4UsetheRemotecontrol........................................ 164.5Load or remove a wireless sensor....................174.6Change the settings via SMS...............................184.6.1 User level................................................................ 184.6.2 Set administrator number.............................. 194.6.3 Set normal users................................................. 194.6.4 Set MMSparameters........................................ 204.6.5 Set emailparameters........................................204.6.6 Set receivephone number.............................. 214.6.7Get on spotphoto............................................... 224.6.8Arm.......................................................................... 224.6.9 Disarm.................................................................... 224.6.10 Check camera settings................................... 234.6.11Set cameraparameters................................... 234.6.12 Format TF card..................................................254.6.13 Get administrator’spasswords...................254.6.14 Get help................................................................ 254.6.15SMS commandlist............................................ 265 Declaration of Conformity.........................................28AppendixⅠ:TechnicalSpecifications...................... 29AppendixⅡ: Parts List.................................................... 30
BG500 series 1 Product Feature21Product Feature1.1General DescriptionThe BG500 series security camera is a miniMMS/GPRS alarm system, based on MMS (MultimediaMessaging Service), GSM SMS (Short Message Service)and GSM voice technologies. When it is activated, it willsend MMS (pictures) alerts to your mobile phone or e-mailaddress immediately once the monitored region isabnormal. Also, it has two way communication functions.You can let the MMS/GPRS alarm system send pictures toyou any time.The BG500 series can monitor your home, office, shop,store, warehouse or factory by your mobile phone fromeverywhere and any time.The MMS/GPRS alarm system BG500 series securitycamera can be programmed by PC programmer toolthrough TF card, USB cables or SMS command. This is aworldwide new solution.1.2 Camera OverviewThe camera has a LCD display for easy setup and has thefollowing I/O interfaces: Power/USB connector, Micro SDcard slot, and SIM card slot.Take a few moments to familiarize with the cameracontrols and displays. It is helpful to bookmark this sectionand refer to it when you read through the rest of themanual.
BG500 series 1 Product Feature31.3 Shooting Information DisplayWhen the camera is turned on (the power switch is slidto ON position), the camera setting information will bedisplayed in the monitor.
BG500 series 1 Product Feature4*The function in ( ) can work only in Setup status;*The function in [ ] can work only in Arm status.
BG500 series 1 Product Feature51.4 Product Feature1. This camera can take 5megapixel photos and VGAvideos.2. It uses TF card (Micro-SD card) to store images andvideos.3. It can send MMS images to the mobile phone or to ane-mail address. It also can give a call to you when thecamera is triggered.4. It uses integrated PIR detector to provide precise andtimely alarm.5. It is equipped with infrared LED. So even in darkenvironment, this camera can get clear B&W images.6. It supports SMS remote control. Users can control thecamera by SMS command or calling.7. Listen in the monitoring area: call the device number tolisten in the monitoring area. (Only pre-set number todial the camera)8. Schedule monitor: user can set the camera’s workingtime as the preset schedule.9. Built-in lithium battery: Rechargeable battery ensuresoperation in case of external power failure.10. Easy installation: wireless connection, suitable forhome use.
BG500 series 2 Cautions62CautionsPlease use this product according to the law. Respectone another’s privacy. Do not monitor other people’shome or privacy. We hold no responsibility for the illegaluse of this product.We don’t guarantee for the document veracity, reliabilityor any content except regulated in proper laws.We hold no responsibility for any loss of data or income;or any special, incidental, consequential or indirectdamages howsoever caused.The contents of this document are provided “as is”.Except as required by applicable law, no warranties ofany kind, either clear or implied, including, but notlimited to the accuracy, reliability or contents of thisdocument. We reserve the right to revise this documentor withdraw it at any time without prior notice.
BG500 series 3 Quick Introductions73QuickStart3.1 TF card and SIM cardOpen the battery cover.Insert TF card and SIM cardinto the card slot inaccordance with the directionshown. Follow the rightdirection.Please make sure thatyour SIM card has openedthe GPRS data businessbefore use.3.2 Battery and power adapterOpen the batterycover. Find the sparelithium battery connectorand insert the lithiumbattery.Connect the poweradapter into thePower/USB interface forpower supply and slide thepower switch to ONposition.Please note that it’srecommended to use the adapter to supply powerand use the lithium battery to be a power backup.If your camera’s Work Mode is Indoor Mode,please supply with power adapter.
BG500 series 3 Quick Introductions83.3 Quick startSTEPS:Step1: confirm cards statusConfirm the TF card and SIM card are insertedcorrectly. You can see the card status on the display.means the SIM card is inserted and works well.means no SIM card or the SIM card is not properlyinserted.TF Capacity means how many pictures can bestored. It should be a nonzero number.Settingsmustbedone1) Must set a administrator number to the securitycamera.2) Must correctlyset the network parameters forMMS and e-mail.3) Must have at least one receiving phone numberand one receiving e-mail address.4) Must correctlysetyourWork Mode: Indoor(Power adapter) or Outdoor (Lithiumbattery).5) Must choose a proper Send to Mode:Phone[MMS], Email[GPRS], Call,Local.*[1-4 canbe set on computer via profile.txt fileor mobilephone via SMS]
BG500 series 3 Quick Introductions9Step2: edit MMS parameters via computer1) Use the USB cable to connect the camera withyour computer.2) Wait for the 10-20 seconds for the camera toacquire a signal. After the SIM card icon appears,press “MENU” to enter into set up interface.3) Select submenu “Send to” to choose Phone[MMS] ,and press “OK’’ to check the settings. Thenpress “OK” again to exit.You will receive the MMS with your mobile phonenotemail.Pleasemakesurethatyourmobilephonealsoopened the data business.4) Select submenu “USB Storage” and enter into“Mass Storage”.5) Find the file “BG500.txt” in a folder named“GSM” in the new removable disk of your computer.Reedit the file “BG500.txt” to set the MMS and GPRSparameters. Below is for reference.
BG500 series 3 Quick Introductions10Different telecom providers have differentparameters. Please contact your network serviceprovider for the detail telecom parameters.Step 3: send MMS manuallyAfter you finish the MMS settings in the computer,please restart your camera.After the camera acquiring the signal and the SIMcard icon appears, target an object and press “►”totake a photo manually.After the number of image changed, press “OK”toplayback the photos, press “▲”and“▼”toswitchto
BG500 series 3 Quick Introductions11previous or next photo. Then press “MENU”andyoucan see a send Phone [MMS] interface, press “OK”tosend out the MMS.After a few seconds, you will receive a MMS in yourphone.Step4: go to Arm StatusArm status is the normal work status. If the camerais in Setup status, you can press “◄” key to switch toarm status. To find the detail of the three statuses,please refer to 4.2.Setup status Arm Status Disarm StatusStep5: get on spot images via SMSWhen the camera is armed and the Send to Modeis Phone [MMS], you can send text message “#T#”toyour camera’s SIM card number to get an on spot image.
BG500 series 4 Advanced Operations124 Advanced Operations4.1 Mount the cameraCamera can be mounted on a wall or put down on anysuitable horizontal surface.1) In accordance with a base board installing hole, makeholes on the wall with a power drill.2) Fix base board with the host by connecting screwhole.3) Press “▲”button to open or close the laser pointer forhelping adjust the shot area.4.2 Three camera statusesFrom the basic operations of the camera in the previouschapter, we know that the camera has three basic operationstatuses:Setup status Arm Status Disarm StatusSetup Status: You can change or check the camerasettings in this status. You also can change camera settingsvia SMS when it’s in Arm status and Indoor Mode.Arm Status: It’s the work status. When there is anintruder, the camera will take photos and send the on shotphotos to your phone or e-mail.Disarm Status: The camera will not be triggered andcan’t take photos in disarm status.
BG500 series 4 Advanced Operations134.3 Change camera settings via control panelTo view the camera settings menu, press MENU in theSetup status. The setup menu will be shown on the LCD.Submenu DescriptionCameraMode There are two camera modes: Camera orVideo.USBStorageAfter you set USB storage, your camera canbe used as a U-disk. You can edit your MMSsettings under USB mode.WorkModeIndoor Mode:You need to use the power adapter topower supply. The lithium battery can be justa backup for urgency. Otherwise, the lithiumbattery will be quickly consumed.Outdoor Mode:You can use the lithium battery as powersupply for several days. But you need to set thecamera work mode as outdoor mode. It’s apower-saving mode, so all 433 wireless sensorsincluding the remote control will not function inoutdoor mode.Note: please fully charge the lithium batterywhen you first use.Set Clock Set date and time.Photo Size You can choose 5 megapixel or 3 megapixelfor picture size.PhotoBurstIt means Continuous Capturing Number.This parameter affects the number of picturestaken for each triggering in Camera mode. It has3 values: “1 Photo” to “3 Photos”.VideoLength It extends from 5 to 60 seconds with a stepof one second.Time Lapse Time lapse means the camera can capture
BG500 series 4 Advanced Operations14images or videos at a preset time intervalsregardless of whether motions are detected. Thedefault parameter is Off which means the timerfunction is disabled. Changing this parameter toa non-zero value turns on the Time Lapse mode,and camera will take photos at given timeinterval.Please note that if the PIR trigger isset to Off, then time lapse can’t be set toOff.Format Format the SD card. All the data includingimages and videos in the SD card will bedeleted.PIR TriggerThis parameter defines the sensitivity of thePIR. There are four parameters: High,Normal, Low and Off. The default value is“Normal”. The higher degree indicates that theCamera is more easily to be triggered by motion,taking more pictures or recording more videos.It is recommended to use high sensitivity degreein room or environment with little interferenceand to use lower sensitivity for outdoor orenvironment with lots of interference like hotwind, smoke, near window etc. Furthermore,the sensitivity of the PIR is strongly related tothe temperature. Higher temperature leads tolower sensitivity. Therefore it is suggested to seta higher sensitivity for high temperatureenvironment.Please note that if time lapse is set toOff, then PIR trigger can’t be set to Off.PIRInterval This parameter means how long the PIR(Passive Infrared motion sensor) will be
BG500 series 4 Advanced Operations15disabled after each triggering in ON mode.During this time the PIR of the device will notreact to the motion of human (or animal). Theminimum interval is 0 second. It means the PIRworks all the time. The maximum interval is 1hour. It means the PIR will be disabled for 1hour after each triggering. The default value is 1minute. Press “◄”and“►” to decreases orincreases the value.Send toThere are 4 Send to modes:1 Phone [MMS]: send images to mobilephone.2 Email [GPRS]: send images to e-mailaddress.3 Call: calling your preset phone number istriggered.4 Local: just store images in the TF card, donot send out.You should set your receiving phonenumber or your receiving e-mail address in theBG500.TXT file to function it.Work Day Choose the days of the week to let thecamera work.Work HourChoose a time period of a day to let thecamera work. The camera will be awaken at thesetting time duration in a day. In the rest of thetime the camera is sleeping. Set Work Hour asOff means the camera works all day.Study CodeThis camera supports to connect with433MHz wireless device, such as infrared bodysensor, wireless door magnet, wireless smokedetector etc. The devices can be set as alarmsensors of the camera. All the device should be
BG500 series 4 Advanced Operations16studied with this camera first. Please see 4.5 tofind the method to connect or remove a wirelesssensor.Format SDIfyouchoose“FormatSD”,thesystemwilldelete all images or videos stored in the SD card.So make sure that you have made a backup ofimportant data.Default Set Restore customer settings to default values.4.4 Use the Remote controlWhen it’s in Indoor Mode, you can use the remotecontrol to easily arm (button A) or disarm (button D). Alsoyou can dial the emergency numbers via button C in case ofemergency. Press button B can open or close the laser (youcan easily mount the camera with the help of the laserpointer.).Button A: Arm the camera;Button D: Disarm the cameraButton C: Emergency call buttonButton B: Laser pointer;
BG500 series 4 Advanced Operations17Setup status Study Code Menu Study Code MenuMethod to add remote control(s) to the camera:Enter the Setup status, press Menu and enter theStudy Code submenu. Choose “RCH”, press OK button,then press button Aof the remote control. When it'ssuccessful, there will be a "*”before RCH.Please note that the remote control just can be used inIndoor Mode.InOutdoor Mode, the remote controlwill not function.4.5 Load or remove a wireless sensorAny 433MHz wireless sensor, such as infrared bodysensor, wireless door magnet, wireless smoke detector etc.can be set as an alarm sensor of the camera.Method to load or remove a wireless sensor:1. Power on the wireless sensor.2. Enter the Setup status, press Menu and enter intothe Study Code submenu. Choose a zone, for exampleZone1, press OK button, then trigger the wireless sensor tocheck if the sensor is loaded successfully. When it'ssuccessful, there will be a "*” before the zone number.
BG500 series 4 Advanced Operations18Setup status Study Code Menu Study Code Menu3. When you want to remove the wireless sensor.Please enter the study code menu, press LEFT button tocancel the “*”. If there is not a “*” before the zone, it meansthe sensor has been removed from the camera.4.6 Change the settings via SMSWhen you are far away from your house, you can getspot photos or change camera settings via SMS.4.6.1 User levelThere are two user levels: administrator and normalusers. Each user has a different authorization level:Functions User LevelSet administrator number Only administrator’spasswordSet administrator ‘s password administratorSet camera parameters administratorSet normal user administratorReceive emergency calling administrator, normaluserSend SMS for on spot picture administrator, normaluserCallthecameratolisteninlivevoice administrator, normaluserReceive MMS when triggered administrator, normal
BG500 series 4 Advanced Operations19userCheck camera status administrator, normaluserGet help information administrator, normaluser4.6.2 Set administrator numberYou should set a administrator number to receiveMMS or control your camera when you first use thiscamera.Method 1: send SMS command:Send #BG500#5555#your phone number# toyour camera’s SIM card.Here 5555 is the original administrator’s password.Please note all the SMS commands should begin and endwith “#”.For example, if your phone number is 13800138000,you can edit #BG500#5555#13800138000# to setyour phone number as the administrator number.If successful, reply SMS: Dear administrator, yournumber is 13800138000.If failed, reply SMS: Please check the password.Method 2: editing the profile file BG500.TXT:Edit administrator Num=138001380004.6.3 Set normal usersYoucansetatmost3normalusers.Andthenormalusers should be set by the administrator.Method 1: send SMS command:#N#13800138001#13800138002#13800138003# Reply SMS: http://mmsc.monternet.com,
BG500 series 4 Advanced Operations2010.0.0.172, 80, cmwap,,, administrator number,PhoneNum2, PhoneNum3, PhoneNum4Method 2: editing the BG500.TXT:PhoneNum2=xxx,PhoneNum3=xxx,PhoneNum4=xxx4.6.4 Set MMS parametersIf you want to get instant MMS images when thecamera is triggered, you should set the MMS parameterscorrectly.Method1: send SMS command:#M#URL#IP#Port#APN#Account#Password#The following chart shows the meaning of each field.Please note there is a “#” between each field. Please don’tforget the character “#” at the end of the command.Please note each field has a max. character numberlimit.If successful, reply SMS:http://mmsc.monternet.com, 10.0.0.172, 80,cmwap, name, password, 13800138000, , , ,If failed, reply SMS: Command error. Pleasecheck again!Method2: Reedit the BG500.TXT in the computer to setthe MMS parameters, below is for reference:For more details of URL, APN, IP, Port, Account andPassword, please contact your network service provider.
BG500 series 4 Advanced Operations214.6.5 Set email parametersYou also can choose Send Email mode to get thepictures via a cheaper channel. This Send Email mode cansend out the pictures via GPRS internet ,not WAP, so thecommunication cost is much lower than MMS.Method1: send SMS command:#S#Sending E-mail address#Sending emailpassword #Sending email server port#GPRS APN#SMTPServer#Account #Password #If successful, reply SMS: bmctest123@sina.com,bmc123,25,cmnet,smtp.sina.com,,,,If failed, reply SMS: Command error! Pleasecheck again.Method 2: re-edit the BG500.TXT in the computer to setthe e-mail parameters.For more details of GPRS APN, GPRS account andGPRS password, please contact your network serviceprovider.4.6.6 Set receive phone numberMethod1: send SMS command:#N# Receive phone number 2# Receive phonenumber 3# Receive phone number 4#
BG500 series 4 Advanced Operations22The first receive phone number is the administratornumber.Reply SMS: http://mmsc.monternet.com,10.0.0.172, 80, cmwap,,,administrator number,receive phone number 1, receive phone number 2,receive phone number 3,Method2: editing the BG500.TXT: fill the receive phonenumber field.4.6.7 Get on spot photoMethod: send SMS command:Edit SMS #T# send to your camera’s SIM card.If successful, the camera will take an on-spot pictureand send to your mobile phone.If failed, reply SMS: Photo error: xx,Settingserror: xx,MMS error: xx or Time out!4.6.8 ArmMethod1: send SMS command:Edit SMS #A# and send to your camera’s SIM card.
BG500 series 4 Advanced Operations23If successful, reply SMS: Arm mode is active!If failed, reply SMS: Command error! Pleasecheck again.Method2: use the remote controlUse the remote control, press the button “A” to armthe camera;4.6.9 DisarmMethod1: send SMS command:Edit SMS #D# and send to your camera’s SIM card.If successful, reply SMS: Disarm mode is active!If failed, reply SMS: Command error! Pleasecheck again.Method2: use the remote controlUse the remote control, press the button “D” todisarm the camera.4.6.10 Check camera settingsMethod1: send SMS command:Edit SMS #L# and send to your camera’s SIM card.If successful, reply SMS: Email address, password,port, SMTP Server, protocol, email1,email2,email3,email4, mms serve net address,server IP,
BG500 series 4 Advanced Operations24port,protocol,Number1,Number2,Number3,Number4,Alarm: on /off, Interval 0m:0s,photoBurst 1, Send Mode: Local/Number/Email, WorkDay 1111111, Timer: off/on 09h00m:17h00m, DateTime:2011/7/12 18:12:12,Active Zone:01111114.6.11 Set camera parametersYou can send SMS commands as the table shows.1 #e#b1# B: Photo burst1: the numbers of continuously takenphoto after trigger (1 picture~3 pictures)2 #e#cv# c: Camera modeV:video;P:photo3#e#t# T:Setclock.4 #e#i5s # I: Trigger interval5s: the range is from 0s to 60m.5 #e#l1h# L: Time lapse1h:off, 5m~59m, 1h~8h6 #e#mp# M: Send modep:phone[MMS]; l :local; e :e-mail;c:call.7 #e#pn# P: PIR Trigger sensitivityn:normal;h:high;l:low;o:off8 #e#s3# S: Photo size3: 3MP or 5MP.9#e#hon10:10-22:22# H: Work houron: on10:10-22:22: it means the PIRsensor will work from 10:10 to 22:22;off: it means the PIR sensor will work allthe time10 #e#v10# V: Video length
BG500 series 4 Advanced Operations2510: the range is from 5s to 60s.11 #e#d1110011# D: Work day:1 means ON,0 means OFF.From Sunday to Saturday.If successful,reply SMS: Arm: On, Photo, 5M,Pir-Trig: Normal, Interval:0s, AV-Len:10s, Lapse:Off, Burst:1, Mode: Phone, W-Day:1110001,W-hour: Off, 2013/01/22 16:41.If failed, reply SMS: Command error! Pleasecheck again.Note: #E# can’t be omitted when use this command tochange any camera settings.4.6.12 Format TF cardMethod1: send SMS command:Edit SMS #F# and send to your camera’s SIM card.If successful, reply SMS: Format SD cardsuccessfully!If failed, reply SMS: Format SD card failed!4.6.13 Get administrator’s passwordsMethod1: send SMS command:Edit SMS #P#your password# and send to your
BG500 series 4 Advanced Operations26camera’s SIM card.If successful ,it will reply SMS: The password issuccessfully changed to 4321.4.6.14 Get helpMethod: send SMS command:Edit SMS #H# and send to your camera’s SIM card.If successful,it will reply SMS:A:Arm,D:Disarm,E:Edit(B:Burst,C:CameraMode,D:WorkDay,H:WorkHour,I:Interval,L:Lapse,M:SendMode,P:PIRTrigger,S:PhotoSize,V:VideoLength,T:TimeSet),F:Format,H:Help,L:Lookover settings,M:MMS,N:Number,P:Password,Receive e-mail,S:Servere-mail,T:Takephoto.4.6.15 SMS command listBelow is a SMS command list for example.No. Function SMS Command1SetadministratorNumber#BG500#5555#13800138000#2Set NormalUsers #N#13800138001#13800138002#13800138003#3 Set MMSParameters #M#http://mmsc.monternet.com#10.0.0.172#80#cmwap#**#**#4 Set EmailParameters #S#bmctest123@sina.com#bmc123#25#cmnet#smtp.sina.com#**#**#5 Set Receiving #N#12345678901#12345678902#12345
BG500 series 4 Advanced Operations27phone address 678903#6 Set ReceivingEmail Address #R#Email1@163.com#Email2@163.com#Email3@163.com#7Get a spotPhoto #T#8 Arm #A#9Disarm #D#10 Check camerasettings #L#11 Set CameraParameters #E #B1#Mp#d1110001#hOFF#t#(B:Burst,C:Camera Mode,D:WorkDay,H:WorkHour,I:Interval,L:Lapse,M:SendMode,P:Pir Trigger,S:Photo Size,V:Video Length,T:Time Set)12 Format TFCard #F#13 Set Password #P#5555#14 Help #H#A:Arm,D:Disarm,E:Edit(B:Burst,C:Camera Mode,D:Work Day,H:WorkHour,I:Interval,L:Lapse,M:SendMode,P:Pir Trigger,S:Photo Size,V:Video Length,T:TimeSet),F:Format,H:Help, L:Look oversettings,M:MMS,N:Number,P:Password,R:Receive email,S:Server email,T:Takephoto.
BG500 series 5 SMS command list285 Declaration of ConformityWe declare on our sole responsibility that thisequipment complies with the essential requirements of theRadio and Telecommunications Terminal EquipmentDirective, 1999/5/EC, and that any applicable EssentialTest Suite measurements have been performed.CE versions of the BG500 whichdisplay the CE symbol on the product label, comply withthe essential requirements of the European Radio andTelecommunication Terminal Directive 1999/5/CE. 1.CAUTION : RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.2.Adapter shall be installed near the equipment and shall be easily accessible. 3. In oder to meet RF exposure,the product should be used at least 20cm apart from user body.
BG500 series AppendixⅠ: Technical Specifications-29-AppendixⅠ: Technical SpecificationsImage Sensor 5MP Color CMOSLens F/NO=3.1mmFOV(Field of View)= 52°Detection Range BG500L: up to 22MBG500K: up to 12MIllumination BG500L: 850nm IR LEDsBG500K: 940nm IR LEDsDisplay Screen 1.4” LCDMemory Card Up to 32GB TF cardPicture Resolution 5MP/1.3MPVideo Resolution VGAPIR Sensor Multi-ZoneTrigger Time 0.3s(indoor mode)Weight * 0.15 kgOperation/Storage Tem. -20 - +25°C / -30 - +25°CInterval 1s – 60 min.Photo Burst 1–3Power Supply 5V2A DC;Lithium battery(backup)Stand-by Current <0.25mA(<6mAh/Day)Display Screen LCD displayDimensions 105x 65x 35 mmOperation Humidity 5% - 90%Security authentication FCC, CE, RoHS*without battery
BG500 series Appendix Ⅱ:PartsList-30-AppendixⅡ: Parts ListPart Name QuantitySecurity camera OneRemote control TwoPower adapter OneLithium battery OneUSB cable OneUniversal mounting kit OneAdhesive tape OneUser Manual OneWarranty Card One433M Wireless sensor (Option)
FCCStatmentThisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatetheequipment.Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,equipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,—Reorientorrelocatethereceivingantenna.—Increasetheseparationbetweentheequipmentandreceiver.—Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.—Consultthedealeroranexperiencedradio/TVtechnicianforhelp.FCCRFRadiationExposureStatemenThisequipmentcomplieswithFCCRFradiationexposurelimitssetforthforanuncontrolledenvironment.Thisequipmentshouldbeinstalledandoperatedwithaminimumdistanceof20centimetersbetweentheradiatorandyourbody.Note:ThemanufacturerisnotresponsibleforanyradioorTVinterferencecausedbyunauthorizedmodificationstothisequipment.Suchmodificationscouldvoidtheuser’sauthoritytooperatetheequipment.