Boly Media Communications 00004 MMS/GPRS Security Camera User Manual
Boly Media Communications (Asia) Co., Ltd. MMS/GPRS Security Camera
User Manual
MMS/GPRS Security Camera User’s Manual BG500 series For model:BG500L/BG500K Content 1 Product Feature................................................................ 2 1.1 General Description................................................ 2 1.2 Camera Overview..................................................... 2 1.3 Shooting Information Display.............................3 1.4 Product Feature........................................................ 5 2 Cautions............................................................................. 6 3 Quick Start........................................................................ 7 3.1 TF card and SIM card.............................................. 7 3.2 Battery and power adapter................................... 7 3.3 Quick start................................................................... 8 4 Advanced Operations................................................. 12 4.1 Mount the camera...................................................12 4.2 Three camera statuses.......................................... 12 4.3 Change camera settings via control panel.... 13 4.4 Use the Remote control........................................ 16 4.5 Load or remove a wireless sensor.................... 17 4.6 Change the settings via SMS...............................18 4.6.1 User level................................................................ 18 4.6.2 Set administrator number.............................. 19 4.6.3 Set normal users................................................. 19 4.6.4 Set MMS parameters........................................ 20 4.6.5 Set email parameters........................................20 4.6.6 Set receive phone number.............................. 21 4.6.7 Get on spot photo............................................... 22 4.6.8 Arm.......................................................................... 22 4.6.9 Disarm.................................................................... 22 4.6.10 Check camera settings................................... 23 4.6.11 Set camera parameters................................... 23 4.6.12 Format TF card..................................................25 4.6.13 Get administrator’s passwords...................25 4.6.14 Get help................................................................ 25 4.6.15SMS command list............................................ 26 5 Declaration of Conformity.........................................28 AppendixⅠ: Technical Specifications...................... 29 AppendixⅡ: Parts List.................................................... 30 -1- BG500 series Product Feature 1 Product Feature 1.1General Description The BG500 series security camera is a mini MMS/GPRS alarm system, based on MMS (Multimedia Messaging Service), GSM SMS (Short Message Service) and GSM voice technologies. When it is activated, it will send MMS (pictures) alerts to your mobile phone or e-mail address immediately once the monitored region is abnormal. Also, it has two way communication functions. You can let the MMS/GPRS alarm system send pictures to you any time. The BG500 series can monitor your home, office, shop, store, warehouse or factory by your mobile phone from everywhere and any time. The MMS/GPRS alarm system BG500 series security camera can be programmed by PC programmer tool through TF card, USB cables or SMS command. This is a worldwide new solution. 1.2 Camera Overview The camera has a LCD display for easy setup and has the following I/O interfaces: Power/USB connector, Micro SD card slot, and SIM card slot. Take a few moments to familiarize with the camera controls and displays. It is helpful to bookmark this section and refer to it when you read through the rest of the manual. BG500 series Product Feature 1.3 Shooting Information Display When the camera is turned on (the power switch is slid to ON position), the camera setting information will be displayed in the monitor. BG500 series Product Feature *The function in ( ) can work only in Setup status; *The function in [ ] can work only in Arm status. BG500 series Product Feature 1.4 Product Feature 1. This camera can take 5megapixel photos and VGA videos. 2. It uses TF card (Micro-SD card) to store images and videos. 3. It can send MMS images to the mobile phone or to an e-mail address. It also can give a call to you when the camera is triggered. 4. It uses integrated PIR detector to provide precise and timely alarm. 5. It is equipped with infrared LED. So even in dark environment, this camera can get clear B&W images. 6. It supports SMS remote control. Users can control the camera by SMS command or calling. 7. Listen in the monitoring area: call the device number to listen in the monitoring area. (Only pre-set number to dial the camera) 8. Schedule monitor: user can set the camera’s working time as the preset schedule. 9. Built-in lithium battery: Rechargeable battery ensures operation in case of external power failure. 10. Easy installation: wireless connection, suitable for home use. BG500 series 2 Cautions 2 Cautions Please use this product according to the law. Respect one another’s privacy. Do not monitor other people’s home or privacy. We hold no responsibility for the illegal use of this product. We don’t guarantee for the document veracity, reliability or any content except regulated in proper laws. We hold no responsibility for any loss of data or income; or any special, incidental, consequential or indirect damages howsoever caused. The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either clear or implied, including, but not limited to the accuracy, reliability or contents of this document. We reserve the right to revise this document or withdraw it at any time without prior notice. BG500 series 3 Quick Introductions 3 Quick Start 3.1 TF card and SIM card Open the battery cover. Insert TF card and SIM card into the card slot in accordance with the direction shown. Follow the right direction. Please make sure that your SIM card has opened the GPRS data business before use. 3.2 Battery and power adapter Open the battery cover. Find the spare lithium battery connector and insert the lithium battery. Connect the power adapter into the Power/USB interface for power supply and slide the power switch to ON position. Please note that it’s recommended to use the adapter to supply power and use the lithium battery to be a power backup. If your camera’s Work Mode is Indoor Mode, please supply with power adapter. BG500 series 3 Quick Introductions 3.3 Quick start Settings must be done 1) Must set a administrator number to the security camera. 2) Must correctly set the network parameters for MMS and e-mail. 3) Must have at least one receiving phone number and one receiving e-mail address. 4) Must correctly set your Work Mode: Indoor (Power adapter) or Outdoor (Lithium battery). 5) Must choose a proper Send to Mode: Phone[MMS], Email[GPRS], Call,Local. *[1-4 can be set on computer via profile.txt file or mobile phone via SMS] STEPS: Step1: confirm cards status Confirm the TF card and SIM card are inserted correctly. You can see the card status on the display. means the SIM card is inserted and works well. means no SIM card or the SIM card is not properly inserted. TF Capacity means how many pictures can be stored. It should be a nonzero number. BG500 series 3 Quick Introductions Step2: edit MMS parameters via computer 1) Use the USB cable to connect the camera with your computer. 2) Wait for the 10-20 seconds for the camera to appears, acquire a signal. After the SIM card icon press “MENU” to enter into set up interface. 3) Select submenu “Send to” to choose Phone [MMS] , and press “OK’’ to check the settings. Then press “OK” again to exit. You will receive the MMS with your mobile phone not email. Please make sure that your mobile phone also opened the data business. 4) Select submenu “USB Storage” and enter into “Mass Storage”. 5) Find the file “BG500.txt” in a folder named “GSM” in the new removable disk of your computer. Reedit the file “BG500.txt” to set the MMS and GPRS parameters. Below is for reference. BG500 series 3 Quick Introductions Different telecom providers have different parameters. Please contact your network service provider for the detail telecom parameters. Step 3: send MMS manually After you finish the MMS settings in the computer, please restart your camera. After the camera acquiring the signal and the SIM appears, target an object and press “►” to card icon take a photo manually. After the number of image changed, press “OK” to playback the photos, press “▲”and“▼” to switch to 10 BG500 series 3 Quick Introductions previous or next photo. Then press “MENU” and you can see a send Phone [MMS] interface, press “OK” to send out the MMS. After a few seconds, you will receive a MMS in your phone. Step4: go to Arm Status Arm status is the normal work status. If the camera is in Setup status, you can press “◄” key to switch to arm status. To find the detail of the three statuses, please refer to 4.2. Setup status Arm Status Disarm Status Step5: get on spot images via SMS When the camera is armed and the Send to Mode is Phone [MMS], you can send text message “#T#” to your camera’s SIM card number to get an on spot image. 11 BG500 series 4 Advanced Operations 4 Advanced Operations 4.1 Mount the camera Camera can be mounted on a wall or put down on any suitable horizontal surface. 1) In accordance with a base board installing hole, make holes on the wall with a power drill. 2) Fix base board with the host by connecting screw hole. 3) Press “▲”button to open or close the laser pointer for helping adjust the shot area. 4.2 Three camera statuses From the basic operations of the camera in the previous chapter, we know that the camera has three basic operation statuses: Setup status Arm Status Disarm Status Setup Status: You can change or check the camera settings in this status. You also can change camera settings via SMS when it’s in Arm status and Indoor Mode. Arm Status: It’s the work status. When there is an intruder, the camera will take photos and send the on shot photos to your phone or e-mail. Disarm Status: The camera will not be triggered and can’t take photos in disarm status. 12 BG500 series 4 Advanced Operations 4.3 Change camera settings via control panel To view the camera settings menu, press MENU in the Setup status. The setup menu will be shown on the LCD. Submenu Description Camera There are two camera modes: Camera or Mode Video. After you set USB storage, your camera can USB be used as a U-disk. You can edit your MMS Storage settings under USB mode. Indoor Mode: You need to use the power adapter to power supply. The lithium battery can be just a backup for urgency. Otherwise, the lithium battery will be quickly consumed. Outdoor Mode: Work You can use the lithium battery as power Mode supply for several days. But you need to set the camera work mode as outdoor mode. It’s a power-saving mode, so all 433 wireless sensors including the remote control will not function in outdoor mode. Note: please fully charge the lithium battery when you first use. Set Clock Set date and time. You can choose 5 megapixel or 3 megapixel Photo Size for picture size. It means Continuous Capturing Number. Photo This parameter affects the number of pictures Burst taken for each triggering in Camera mode. It has 3 values: “1 Photo” to “3 Photos”. Video It extends from 5 to 60 seconds with a step Length of one second. Time Lapse Time lapse means the camera can capture 13 BG500 series 4 Advanced Operations images or videos at a preset time intervals regardless of whether motions are detected. The default parameter is Off which means the timer function is disabled. Changing this parameter to a non-zero value turns on the Time Lapse mode, and camera will take photos at given time interval. Please note that if the PIR trigger is set to Off, then time lapse can’t be set to Off. Format the SD card. All the data including Format images and videos in the SD card will be deleted. This parameter defines the sensitivity of the PIR. There are four parameters: High, Normal, Low and Off. The default value is “Normal”. The higher degree indicates that the Camera is more easily to be triggered by motion, taking more pictures or recording more videos. It is recommended to use high sensitivity degree in room or environment with little interference PIR Trigger and to use lower sensitivity for outdoor or environment with lots of interference like hot wind, smoke, near window etc. Furthermore, the sensitivity of the PIR is strongly related to the temperature. Higher temperature leads to lower sensitivity. Therefore it is suggested to set a higher sensitivity for high temperature environment. Please note that if time lapse is set to Off, then PIR trigger can’t be set to Off. PIR This parameter means how long the PIR Interval (Passive Infrared motion sensor) will be 14 BG500 series 4 Advanced Operations disabled after each triggering in ON mode. During this time the PIR of the device will not react to the motion of human (or animal). The minimum interval is 0 second. It means the PIR works all the time. The maximum interval is 1 hour. It means the PIR will be disabled for 1 hour after each triggering. The default value is 1 minute. Press “◄” and “►” to decreases or increases the value. There are 4 Send to modes: 1 Phone [MMS]: send images to mobile phone. 2 Email [GPRS]: send images to e-mail address. 3 Call: calling your preset phone number is Send to triggered. 4 Local: just store images in the TF card, do not send out. You should set your receiving phone number or your receiving e-mail address in the BG500.TXT file to function it. Choose the days of the week to let the Work Day camera work. Choose a time period of a day to let the camera work. The camera will be awaken at the Work Hour setting time duration in a day. In the rest of the time the camera is sleeping. Set Work Hour as Off means the camera works all day. This camera supports to connect with 433MHz wireless device, such as infrared body Study Code sensor, wireless door magnet, wireless smoke detector etc. The devices can be set as alarm sensors of the camera. All the device should be 15 BG500 series 4 Advanced Operations studied with this camera first. Please see 4.5 to find the method to connect or remove a wireless sensor. If you choose “Format SD”, the system will delete all images or videos stored in the SD card. Format SD So make sure that you have made a backup of important data. Default Set Restore customer settings to default values. 4.4 Use the Remote control When it’s in Indoor Mode, you can use the remote control to easily arm (button A) or disarm (button D). Also you can dial the emergency numbers via button C in case of emergency. Press button B can open or close the laser (you can easily mount the camera with the help of the laser pointer.). Button A: Arm the camera; Button D: Disarm the camera Button C: Emergency call button Button B: Laser pointer; 16 BG500 series Setup status 4 Advanced Operations Study Code Menu Study Code Menu Method to add remote control(s) to the camera: Enter the Setup status, press Menu and enter the Study Code submenu. Choose “RCH”, press OK button, then press button A of the remote control. When it's successful, there will be a "*”before RCH. Please note that the remote control just can be used in Indoor Mode. In Outdoor Mode, the remote control will not function. 4.5 Load or remove a wireless sensor Any 433MHz wireless sensor, such as infrared body sensor, wireless door magnet, wireless smoke detector etc. can be set as an alarm sensor of the camera. Method to load or remove a wireless sensor: 1. Power on the wireless sensor. 2. Enter the Setup status, press Menu and enter into the Study Code submenu. Choose a zone, for example Zone1, press OK button, then trigger the wireless sensor to check if the sensor is loaded successfully. When it's successful, there will be a "*” before the zone number. 17 BG500 series Setup status 4 Advanced Operations Study Code Menu Study Code Menu 3. When you want to remove the wireless sensor. Please enter the study code menu, press LEFT button to cancel the “*”. If there is not a “*” before the zone, it means the sensor has been removed from the camera. 4.6 Change the settings via SMS When you are far away from your house, you can get spot photos or change camera settings via SMS. 4.6.1 User level There are two user levels: administrator and normal users. Each user has a different authorization level: Functions User Level Set administrator number Only administrator’s password Set administrator ‘s password administrator Set camera parameters administrator Set normal user administrator Receive emergency calling administrator, normal user Send SMS for on spot picture administrator, normal user Call the camera to listen in live administrator, normal voice user Receive MMS when triggered administrator, normal 18 BG500 series 4 Advanced Operations Check camera status Get help information user administrator, normal user administrator, normal user 4.6.2 Set administrator number You should set a administrator number to receive MMS or control your camera when you first use this camera. Method 1: send SMS command: Send #BG500#5555#your phone number# to your camera’s SIM card. Here 5555 is the original administrator’s password. Please note all the SMS commands should begin and end with “#”. For example, if your phone number is 13800138000, you can edit #BG500#5555#13800138000# to set your phone number as the administrator number. If successful, reply SMS: Dear administrator, your number is 13800138000. If failed, reply SMS: Please check the password. Method 2: editing the profile file BG500.TXT: Edit administrator Num=13800138000 4.6.3 Set normal users You can set at most 3 normal users. And the normal users should be set by the administrator. Method 1: send SMS command: #N#13800138001#13800138002#1380013800 3# Reply SMS: http://mmsc.monternet.com, 19 BG500 series 4 Advanced Operations 10.0.0.172, 80, cmwap,,, administrator number, PhoneNum2, PhoneNum3, PhoneNum4 Method 2: editing the BG500.TXT: PhoneNum2=xxx,PhoneNum3=xxx,PhoneNu m4=xxx 4.6.4 Set MMS parameters If you want to get instant MMS images when the camera is triggered, you should set the MMS parameters correctly. Method1: send SMS command: #M#URL#IP#Port#APN#Account#Password# The following chart shows the meaning of each field. Please note there is a “#” between each field. Please don’t forget the character “#” at the end of the command. Please note each field has a max. character number limit. If successful, reply SMS: http://mmsc.monternet.com, 10.0.0.172, 80, cmwap, name, password, 13800138000, , , , If failed, reply SMS: Command error. Please check again! Method2: Reedit the BG500.TXT in the computer to set the MMS parameters, below is for reference: For more details of URL, APN, IP, Port, Account and Password, please contact your network service provider. 20 BG500 series 4 Advanced Operations 4.6.5 Set email parameters You also can choose Send Email mode to get the pictures via a cheaper channel. This Send Email mode can send out the pictures via GPRS internet ,not WAP, so the communication cost is much lower than MMS. Method1: send SMS command: #S#Sending E-mail address#Sending email password #Sending email server port#GPRS APN# SMTPServer#Account #Password # If successful, reply SMS: bmctest123@sina.com , bmc123,25,cmnet,smtp.sina.com,,,, If failed, reply SMS: Command error! Please check again. Method 2: re-edit the BG500.TXT in the computer to set the e-mail parameters. For more details of GPRS APN, GPRS account and GPRS password, please contact your network service provider. 4.6.6 Set receive phone number Method1: send SMS command: #N# Receive phone number 2# Receive phone number 3# Receive phone number 4# 21 BG500 series 4 Advanced Operations The first receive phone number is the administrator number. Reply SMS: http://mmsc.monternet.com, 10.0.0.172, 80, cmwap,,,administrator number, receive phone number 1, receive phone number 2, receive phone number 3, Method2: editing the BG500.TXT: fill the receive phone number field. 4.6.7 Get on spot photo Method: send SMS command: Edit SMS #T# send to your camera’s SIM card. If successful, the camera will take an on-spot picture and send to your mobile phone. If failed, reply SMS: Photo error: xx, Settings error: xx, MMS error: xx or Time out! 4.6.8 Arm Method1: send SMS command: Edit SMS #A# and send to your camera’s SIM card. 22 BG500 series 4 Advanced Operations If successful, reply SMS: Arm mode is active! If failed, reply SMS: Command error! Please check again. Method2: use the remote control Use the remote control, press the button “A” to arm the camera; 4.6.9 Disarm Method1: send SMS command: Edit SMS #D# and send to your camera’s SIM card. If successful, reply SMS: Disarm mode is active! If failed, reply SMS: Command error! Please check again. Method2: use the remote control Use the remote control, press the button “D” to disarm the camera. 4.6.10 Check camera settings Method1: send SMS command: Edit SMS #L# and send to your camera’s SIM card. If successful, reply SMS: Email address, password, port, SMTP Server, protocol, email1,email2, email3,email4, mms serve net address,server IP, 23 BG500 series 4 Advanced Operations port, protocol,Number1,Number2,Number3, Number4, Alarm: on /off, Interval 0m:0s,photo Burst 1, Send Mode: Local/Number/Email, Work Day 1111111, Timer: off/on 09h00m:17h00m, Date Time:2011/7/12 18:12:12,Active Zone:0111111 4.6.11 Set camera parameters You can send SMS commands as the table shows. 1 #e#b1# B: Photo burst 1: the numbers of continuously taken photo after trigger (1 picture~3 pictures) 2 #e#cv# c: Camera mode V:video;P:photo 3 #e#t# T: Set clock. 4 #e#i5s # I: Trigger interval 5s: the range is from 0s to 60m. 5 #e#l1h# L: Time lapse 1h:off, 5m~59m, 1h~8h 6 #e#mp# M: Send mode p : phone[MMS]; l : local; e : e-mail; c:call. 7 #e#pn# P: PIR Trigger sensitivity n:normal;h:high;l:low;o:off 8 #e#s3# S: Photo size 3: 3MP or 5MP. 9 #e#hon10:1 H: Work hour 0-22:22# on: on10:10-22:22: it means the PIR sensor will work from 10:10 to 22:22 ; off: it means the PIR sensor will work all the time 10 #e#v10# V: Video length 24 BG500 series 4 Advanced Operations 10: the range is from 5s to 60s. 11 #e#d111001 D: Work day:1 means ON,0 means OFF. 1# From Sunday to Saturday. If successful,reply SMS: Arm: On, Photo, 5M, Pir-Trig: Normal, Interval:0s, AV-Len:10s, Lapse: Off, Burst:1, Mode: Phone, W-Day:1110001, W-hour: Off, 2013/01/22 16:41. If failed, reply SMS: Command error! Please check again. Note: #E# can’t be omitted when use this command to change any camera settings. 4.6.12 Format TF card Method1: send SMS command: Edit SMS #F# and send to your camera’s SIM card. If successful, reply SMS: Format SD card successfully! If failed, reply SMS: Format SD card failed! 4.6.13 Get administrator’s passwords Method1: send SMS command: Edit SMS #P#your password# and send to your 25 BG500 series 4 Advanced Operations camera’s SIM card. If successful , it will reply SMS: The password is successfully changed to 4321. 4.6.14 Get help Method: send SMS command: Edit SMS #H# and send to your camera’s SIM card. If successful,it will reply SMS: A:Arm, D:Disarm, E:Edit (B: Burst, C: Camera Mode, D: Work Day, H: Work Hour, I: Interval, L: Lapse, M: Send Mode, P: PIR Trigger, S: Photo Size, V: Video Length, T: Time Set), F: Format, H: Help, L: Look over settings, M:MMS, N:Number, P:Password, Receive e-mail, S: Server e-mail, T: Take photo. 4.6.15 SMS command list Below is a SMS command list for example. N Function SMS Command o. 1 Set #BG500#5555#13800138000# administrator Number 2 Set Normal #N#13800138001#13800138002#1380 Users 0138003# 3 Set MMS #M#http://mmsc.monternet.com#10.0. Parameters 0.172#80#cmwap#**#**# 4 Set Email #S#bmctest123@sina.com#bmc123#25# Parameters cmnet#smtp.sina.com#**#**# 5 Set Receiving #N#12345678901#12345678902#12345 26 BG500 series 4 Advanced Operations phone address 6 Set Receiving Email Address 7 Get a spot Photo 8 Arm 9 Disarm 10 Check camera settings 11 Set Camera Parameters 678903# #R#Email1@163.com#Email2@163.com #Email3@163.com# #T# #A# #D# #L# #E #B1#Mp#d1110001#hOFF#t# (B:Burst,C:Camera Mode,D:Work Day,H:Work Hour,I:Interval,L:Lapse,M:Send Mode,P:Pir Trigger,S:Photo Size, V:Video Length,T:Time Set) TF #F# 12 Format Card 13 Set Password 14 Help #P#5555# #H# A:Arm,D:Disarm,E:Edit(B:Burst,C:Came ra Mode,D:Work Day,H:Work Hour,I:Interval,L:Lapse,M:Send Mode,P:Pir Trigger,S:Photo Size, V:Video Length,T:Time Set),F:Format,H:Help, L:Look over settings,M:MMS,N:Number,P:Password, R:Receive email,S:Server email,T:Take photo. 27 BG500 series 5 SMS command list 5 Declaration of Conformity We declare on our sole responsibility that this equipment complies with the essential requirements of the Radio and Telecommunications Terminal Equipment Directive, 1999/5/EC, and that any applicable Essential Test Suite measurements have been performed. CE versions of the BG500 which display the CE symbol on the product label, comply with the essential requirements of the European Radio and Telecommunication Terminal Directive 1999/5/CE. 1.CAUTION : RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. 2.Adapter shall be installed near the equipment and shall be easily accessible. 3. In oder to meet RF exposure,the product should be used at least 20cm apart from user body. 28 BG500 series AppendixⅠ: Technical Specifications AppendixⅠ: Technical Specifications Image Sensor Lens Detection Range Illumination Display Screen Memory Card Picture Resolution Video Resolution PIR Sensor Trigger Time Weight * Operation/Storage Tem. Interval Photo Burst Power Supply Stand-by Current Display Screen Dimensions Operation Humidity Security authentication *without battery 5MP Color CMOS F/NO=3.1mm FOV(Field of View)= 52° BG500L: up to 22M BG500K: up to 12M BG500L: 850nm IR LEDs BG500K: 940nm IR LEDs 1.4” LCD Up to 32GB TF card 5MP/1.3MP VGA Multi-Zone 0.3s(indoor mode) 0.15 kg -20 - +25°C / -30 - +25°C 1s – 60 min. 1–3 5V2A DC; Lithium battery(backup) < 0.25 mA (<6mAh/Day) LCD display 105x 65x 35 mm 5% - 90% FCC, CE, RoHS - 29 - BG500 series Appendix Ⅱ: Parts List AppendixⅡ: Parts List Part Name Security camera Remote control Power adapter Lithium battery USB cable Universal mounting kit Adhesive tape User Manual Warranty Card 433M Wireless sensor Quantity One Two One One One One One One One (Option) - 30 - FCC Statment This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC RF Radiation Exposure Statemen This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2013:11:20 17:58:28+08:00 Create Date : 2013:05:22 14:01:48+08:00 Metadata Date : 2013:11:20 17:58:28+08:00 Format : application/pdf Title : E:\BL\work\BG500L\说明书\BG500 User's Manual(2013-04-26,正式版).doc Creator : jicheng_huang Document ID : uuid:d4e26eef-603a-4d28-a235-ecfc7f66c70b Instance ID : uuid:e64678ed-50f6-48de-96a7-5db256828b16 Page Count : 32 Author : jicheng_huangEXIF Metadata provided by EXIF.tools