Bosch Security Systems BRL1-WY WLSN RELAY MODULE User Manual USERS MANUAL
Bosch Security Systems, Inc. WLSN RELAY MODULE USERS MANUAL
USERS MANUAL
wireless Local SecurityNetwork (915 MHz) Reference Guide EN wLSN wLSN | Reference Guide | Contents Contents 1.0 Using this Document..........................................................4 2.0 Installation Considerations ...............................................6 3.0 3.1 3.2 3.3 3.4 RFSS Mode (RF Signal Strength) ......................................7 RFSS Site Evaluation ............................................................... 8 RFSS Automatic Entry ............................................................ 14 Manual RFSS Testing............................................................. 16 RFSS Remote Entry ............................................................... 18 4.0 Discovering a wLSN Device .............................................20 5.0 Defaulting a wLSN Device................................................21 6.0 wLSN Devices...................................................................22 6.1 wLSN Installation Tool (ISW-BIT-HCY)......................... 22 6.2 wLSN Hub (ISW-BHB1-WY)..................................... 24 6.3 wLSN PIR and Dual Motion Detectors (ISW-BPR1-W13PY, ISW-BPR1-W13PGY)............................ 27 6.4 wLSN Door-Window Contact (ISW-BMC1-S135Y)......... 31 6.5 wLSN Recessed Door-Window Contact (ISW-BMC1-R135Y) ............................................................... 34 6.6 wLSN Mini Door-Window Contact (ISW-BMC1-M82Y)..... 36 6.7 wLSN Inertia Detector (ISW-BIN1-S135Y) ..................... 37 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | Contents 6.8 wLSN Key Fob (ISW-BKF1-H5Y) .................................. 41 6.9 wLSN Relay Module (ISW-BRL1-WY) ......................... 43 6.10 wLSN Indoor Siren (ISW-BSR1-WY)............................. 44 6.11 wLSN Smoke and Heat Detector (ISW-BSM1-SY).. 45 6.12 wLSN Glass Break Detector (ISW-BGB1-SAY).......... 52 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 1.0 Using this Document Trademarks Pet Friendly® is a registered trademark of Bosch Security Systems, Inc. in the United States. 1.0 Using this Document This document contains the basic information that a trained installer needs to install the wireless Local SecurityNetwork (wLSN). It supplements the documents listed in Table 1 on page 5. This reference guide contains: • • • A description of the wLSN general installation procedure (Section 2.0 Installation Considerations on page 6). Device-specific installation procedures (Sections 6.1 through 6.12 starting on page 22). A description of the icons used in the wLSN documentation (Appendix on page 61). Use this document along with the control panel’s documentation and each device’s installation instructions to complete the installation process. When you see the following logo in the wLSN installation instructions listed in Table 1 on page 5, refer to the appropriate section in this document. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 1.0 Using this Document Table 1: wLSN Products and Instructions Product Document ISW-BIT1-HCY wLSN Installation Tool Installation Instructions wLSN Hub Installation Instructions wLSN PIR Motion Detector Installation Instructions wLSN Dual Motion Detector Installation Instructions wLSN Door-Window Contact Installation Instructions wLSN Recessed Door-Window Contact Installation Instructions wLSN Mini Door-Window Contact Installation Instructions wLSN Inertia Detector Installation Instructions wLSN Key Fob Installation Instructions wLSN Relay Module Installation Instructions wLSN Siren Installation Instructions wLSN Smoke Detector Installation Instructions wLSN Glass Break Installation Instructions Easy Series Installer Guide ISW-BHB1-WY ISW-BPR1-W13PY ISW-BDL1-W11PGY ISW-BMC1-S135Y ISW-BMC1-R135Y ISW-BMC1-M82Y ISW-BIN1-S135Y ISW-BKF1-H5Y ISW-BRL1-WY ISW-BSR1-WY ISW-BSM1-SY ISW-BGB1-SAY ICP-EZM2 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 Document Part Number F01U008748 F01U500915 F01U500908 F01U500901 F01U500909 F01U011878 F01U011876 F01U011980 F01U001565 F01U009264 F01U009265 F01U012075 F01U027173 F01U025147 wLSN | Reference Guide | 2.0 Installation Considerations 2.0 Installation Considerations This device complies with Part 15 of the FCC rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This device must accept any interference received, including interference that might cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Refer to the control panel’s documentation for detailed instructions on wLSN programming and device setup. Dispose of used batteries according to manufacturer’s instructions. • • • wLSN devices are intended only for indoor, dry applications. Avoid mounting wLSN devices in areas with large metallic objects, electrical panels (for example: control panel or fuse box) or electric motors. They might reduce the radio-frequency (RF) range of a wLSN device. Avoid installing the devices where excessive humidity or moisture, or temperatures outside of the acceptable operating range exist. • When installing a wLSN Network, plan your installation based on the control panel and wLSN specifications, and the radio-frequency signal strength (RFSS) between remote devices and the wLSN Hub. • The antennas used in fixed mounted wLSN transceivers must be installed to provide a separation distance of at least 8 in. (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Table 2: General Specifications Range (open field) Humidity range Frequency band 1.6 km (1 mile) 0% to 95% 915 to 928 MHz Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) 3.0 RFSS Mode (RF Signal Strength) Before permanently installing any wLSN device, verify that the radio-frequency signal strength (RFSS) between the planned device location and the planned wLSN Hub location is acceptable. CAUTION: If you have wireless devices that you will not immediately install, reinsert the battery tabs or remove the batteries to prevent battery depletion. The wLSN Smoke Detector cannot show RFSS results. Use the Installation Tool or another type of wLSN device to test the desired location for RFSS. There are four methods for entering RFSS Mode: • • RFSS Site Evaluation: Use this option to test RFSS at a desired location for a new device installation. Refer to page 8 for more information. RFSS Automatic Entry: Use this option to control device point assignment by enrolling one device at a time into the system. Refer to page 14 for more information. RFSS Automatic Entry is part of incremental device enrollment. To use RFSS Automatic Entry, ensure your control panel supports incremental device enrollment. Otherwise, refer to Section 3.1 RFSS Site Evaluation on page 8 to enter RFSS and enroll devices. • • Manual RFSS Testing: Use this option to manually enter a device into RFSS Mode for troubleshooting purposes while maintaining normal network operation in an existing installation. The wLSN Hub remains in normal operating mode. Refer to page 16 for more information. RFSS Remote Entry: Use this option to remotely enter RFSS Mode from the control panel or a telephone. Refer to page 18 for more information. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) 3.1 RFSS Site Evaluation To test RFSS at a desired location for a new device installation: 1. Prepare the wLSN Hub for site testing. Refer to Section 3.1.1. 2. Test the site for acceptable RFSS using one of the following options: 3.1.1 The wLSN Hub and a device Refer to Section 3.1.2 on page 9. The wLSN Hub and the Installation Tool Refer to Section 3.1.3 on page 11. Preparing the wLSN Hub for Site Testing and RFSS Mode If the hub is already part of a system, note the original switch settings on the wLSN Hub before setting the switches for RFSS mode. 1. Rotate the enclosure locking mechanism on the wLSN Hub to the unlocked position, and remove the wLSN Hub from the base. 2. Set Switch S1 to 9, Switch S2 to 2, and Switch S3 to 0 to enable RFSS mode. This disables normal operation. Refer to Figure 1. Figure 1: wLSN Hub Switches S1 S2 S3 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) 3. Find a suitable location for the hub base and apply power by either connecting it to the control panel (refer to the control panel’s installation instructions), or temporarily connecting a 9 VDC to 12 VDC battery. 4. Insert the wLSN Hub back into the base. Rotate the enclosure locking mechanism to the locked position. 5. Proceed to the appropriate procedure as selected in Step 2 of Section 3.1 RFSS Site Evaluation. 3.1.2 RFSS Testing Between wLSN Hub and Device 1. Take the device being tested to its planned mounting location. 2. Remove and re-insert the device’s batteries. The device’s LED turns on for approximately 5 sec. 3. Quickly press and release the tamper switch button (refer to Figure 2) four times while the LED is on (5 sec) to enter RFSS mode. Figure 2: Device Tamper Switches 1- Button style tamper switch 2- Lever style tamper switch The wLSN Hub and device exchange data packets for approximately 7 to 11 sec. During this time, the device’s LED flashes ultra-fast. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) When the data exchange is complete, the device’s LED shows the RFSS evaluation results for approximately 15 sec. Figure 3: RFSS Evaluation Results 1- Ultra fast flash (ON 0.1 sec/OFF 0.1 sec): Data packet exchange 2- Fast flash (ON 0.2 sec/OFF 0.2 sec): Acceptable RFSS 3- Slow flash (ON 1 sec/OFF 1 sec): Unacceptable RFSS 4- Blip (ON 0.1 sec/OFF 10 sec): No signal If the RFSS is unacceptable, reposition the device and restart RFSS evaluation until an acceptable location is found. If necessary, reposition the wLSN Hub. After the 15-sec display period, the device’s LED turns off. 10 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) 4. To start a new RFSS session, press and release the device’s tamper switch once. To force a device out of RFSS Mode, press and hold the device’s tamper switch for 5 sec, or remove and reinsert the device’s batteries. 5. Repeat this procedure for each device you are testing. When you finish testing the devices, return the wLSN Hub’s switches to their original position. 3.1.3 RFSS Testing Between wLSN Hub and Installation Tool The LCD Display is 2 lines by 16 characters. The LCD display flashes and beeps the sounder every 4 sec with each information update. 1. Take the Installation Tool to the device’s planned mounting location. 2. Press any key on the Installation Tool to awaken it. 3. Press and hold the [*] and [#] key together to enter RFSS mode. The LCD display shows: To select a mode, press its numerical key, for example, press [2] for Mode 2. 4. Hold the Installation Tool at the device’s planned mounting location. Use Mode 1 to determine if the signal strength is acceptable or not. Mode 2 helps you determine how acceptable the signal strength is. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 11 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) Refer to Mode 1 and Mode 2 (page 12) for more information on acceptable signal strength levels. If the RFSS is unacceptable, reposition either the wLSN Hub or the Installation Tool until an acceptable location is found. 5. Repeat this procedure for each device’s location you are testing. When you finish testing locations, return the wLSN Hub’s switches to their original position. Mode 1 Select Mode 1 by pressing [1]. If the RFSS is acceptable the LCD shows: If the RFSS is unacceptable the LCD shows: Mode 2 To select Mode 2: 1. Press [2]. The LCD shows: 2. Press [0]. The Installation Tool collects data for 5 sec. The LCD shows: After 5 sec, the Installation Tool beeps and shows the RFSS evaluation results for 15 sec: 12 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) Mode 2 provides two indicators of signal strength: Packet Success Ratio (PSR) and Received Signal Strength (RSS). PSR is the ratio of successfully received packets to sent packets. The Installation Tool shows PSR as a percentage. For example, if the wLSN Hub sends 10 packets and the Installation Tool receives 9 packets, the PSR is 90%. RSS indicates the power level of the received messages. The Installation Tool shows RSS using power bars. The maximum number of bars is five. The best location for placing the device is the one that shows the highest PSR percentage and the highest number of power bars. A PSR of 100% and five RSS power bars indicates the strongest signal, which identifies the best location. Table 3: Interpreting Mode 2 Display Power Bars PSR Evaluation 50% - 59% Unacceptable 50% - 59% Marginal (not recommended) 60% - 69% Acceptable 70% - 79% Good 80% - 89% Very good 90% - 99% Excellent When the 15-sec display period ends, the LCD shows: Exiting RFSS Mode The Installation Tool automatically exits RFSS Mode 5 min after the last key press. You can also press and hold the [*] and [#] keys together to exit RFSS Mode. The Installation Tool powers down from the main menu 30 sec after the last key press. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 13 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) 3.2 RFSS Automatic Entry RFSS Automatic Entry is part of incremental device enrollment. To use RFSS Automatic Entry, ensure your control panel supports incremental device enrollment. Otherwise, refer to Section 3.1 RFSS Site Evaluation on page 8 to enter RFSS and enroll devices. To check RFSS and enroll devices one at a time into the system: 1. Start the discovery process from the control panel. Refer to your control panel’s installation instructions. 2. Install the batteries or remove the battery tab from the device when the system prompts you to do so. The following events occur: a. The device’s LED turns on for approximately 5 sec to indicate a successful power-up self-test. b. The device detects the system. c. The wLSN Hub and device exchange data packets. During this exchange, the device’s LED turns off for approximately 7 to 11 sec. d. When the data exchange is complete, the device’s LED shows the RFSS evaluation results for approximately 15 sec. 14 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) Figure 4: RFSS Evaluation Results 5- Ultra fast flash (ON 0.1 sec/OFF 0.1 sec): Data packet exchange 6- Fast flash (ON 0.2 sec/OFF 0.2 sec): Acceptable RFSS 7- Slow flash (ON 1 sec/OFF 1 sec): Unacceptable RFSS 8- Blip (ON 0.1 sec/OFF 10 sec): No signal If the RFSS is unacceptable, reposition the device and restart RFSS evaluation (refer to Step 3) until an acceptable location is found. If necessary, reposition the wLSN Hub. e. After the 15-sec display period, the device’s LED turns off. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 15 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) 3. To start a new RFSS session, press and release the device’s tamper switch once. Steps 2c and 2d repeat. 4. To force a device out of RFSS Mode, press and hold the device’s tamper switch for 5 sec. Before the device exits RFSS Mode, it tests for RFSS again and shows the results on its LED for approximately 15 sec. 5. When the discovery process is complete, the system exits RFSS Mode. To test the device, fault and restore the device’s input (for example, remove the magnet from the doorwindow contact) once. At this time, the system announces the point number it assigned to the device. 3.3 Manual RFSS Testing To place a specific device into RFSS Mode for troubleshooting purposes: 1. Remove the device from where it is mounted. 2. Remove and re-insert the batteries. The device’s LED turns on for approximately 5 sec. During this time, quickly press and release the device’s tamper switch four times. Figure 5: Device Tamper Switches 3- Button style tamper switch 4- Lever style tamper switch The following events occur: a. The wLSN Hub and device exchange data packets for approximately 7 to 11 sec. During this time, the device’s LED flashes ultra-fast. 16 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) b. When the data exchange is complete, the device’s LED shows the RFSS evaluation results for approximately 15 sec: Figure 6: RFSS Evaluation Results 9- Ultra fast flash (ON 0.1 sec/OFF 0.1 sec): Data packet exchange 10- Fast flash (ON 0.2 sec/OFF 0.2 sec): Acceptable RFSS 11- Slow flash (ON 1 sec/OFF 1 sec): Unacceptable RFSS 12- Blip (ON 0.1 sec/OFF 10 sec): No signal If the RFSS is unacceptable, reposition the device until an acceptable location is found. If necessary, reposition the wLSN Hub. c. After the 15-sec display period, the device’s LED turns off. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 17 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) 3. To start a new RFSS session, press and release the device’s tamper switch once. To manually exit RFSS Mode, press and hold the device’s tamper switch for 5 sec, or remove and reinsert the device’s batteries. 4. Repeat this procedure for each device you are testing. 3.4 RFSS Remote Entry Use this option to remotely enter and exit RFSS Mode. 1. Use the control panel or a telephone to enter RFSS Mode. Refer to your control panel’s installation instructions for more information. 2. Select the desired wLSN device. The wLSN Hub and device exchange data packets for approximately 7 to 11 sec. During this time, the device’s LED flashes ultra-fast. 3. When the data exchange is complete, the device’s LED shows the RFSS evaluation results for approximately 15 sec: 18 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 3.0 RFSS Mode (RF Signal Strength) Figure 7: RFSS Evaluation Results 13- Ultra fast flash (ON 0.1 sec/OFF 0.1 sec): Data packet exchange 14- Fast flash (ON 0.2 sec/OFF 0.2 sec): Acceptable RFSS 15- Slow flash (ON 1 sec/OFF 1 sec): Unacceptable RFSS 16- Blip (ON 0.1 sec/OFF 10 sec): No signal The system also announces “Pass,” “Low,” or “Missing.” If the RFSS is unacceptable, reposition the device until an acceptable location is found. If necessary, reposition the wLSN Hub. After the 15-sec display period, the device’s LED turns off. 4. To start a new RFSS session, repeat Step 1 on page 18. To manually exit RFSS Mode, enter the appropriate command at the control panel. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 19 wLSN | Reference Guide | 4.0 Discovering a wLSN Device 4.0 Discovering a wLSN Device Discovery is the process through which the wLSN Hub identifies and includes new devices into a system. In order for the wireless network to operate properly, the following process must occur as shown below: Discover Devices Establish Network Configure Network Configure Devices Test Devices For specific information on the discovery process, refer to your control panel documentation. To default a device that is already enrolled into an existing wireless network, refer to Section 5.0 on page 21. 20 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 5.0 Defaulting a wLSN Device 5.0 Defaulting a wLSN Device Defaulting a wLSN device returns it to an undiscovered state. Once a device is defaulted, it can be enrolled into a wireless network. To ensure a device is defaulted: 1. Remove the batteries. 2. Press and hold the tamper switch button. Refer to Figure 1 on page 9. 3. Reinsert the batteries while holding the tamper switch button. The device’s LED turns on. 4. Release the tamper switch button within five sec after the device’s LED turns on. The device’s LED briefly turns off and then on, indicating that the device was successfully defaulted. This process does not work for the Smoke Detector. Refer to Section 6.11.7 Defaulting the Smoke Detector on page 50. If the wall tamper tab is removed on the Glass Break Detector, refer to Defaulting the Glass Break Detector on page 60 to enter RFSS Mode or return the Glass Break Detector to an undiscovered state. When the Inertia Detector is defaulted, its LED briefly turns off and on, and then it enters Test Mode. Refer to Section 6.7.2 on page 40 for more information. To default a Key Fob, delete the user from the control panel, and then re-enter the user without the key fob. Refer to the control panel documentation for instructions. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 21 wLSN | Reference Guide | 6.0 wLSN Devices 6.0 wLSN Devices 6.1 wLSN Installation Tool (ISW-BIT-HCY) Use the wLSN Installation Tool to determine the best locations for wLSN device installation. The Installation Tool communicates signal strength and packet success ratios through an LCD display. Table 4: Power Installation Tool Specifications Docked Batteries 12 VDC nominal, 7 VDC to 14 VDC (12 VDC plug-in power pack supplied) 3 AAA NiMH rechargeable batteries that require an initial charge of at least 7 hours of charging. Operating Life: Up to 50 hours of continuous use on a single charge. The crescent-shaped LED indicates charging status when placed in a docking station (Table 5). Table 5: wLSN Installation Tool LED Status LED (Figure 8 on page 23) On Off Flashing Flashing power indicator 22 Status Batteries fully charged Installation Tool operation on battery only. Batteries charging Low battery (Figure 8 on page 23) Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices Figure 8: wLSN Installation Tool BOSCH 1- Power Indicator 2- Charging Status LED Bosch Security Systems, Inc. | 12/07 | F01U066216-03 23 wLSN | Reference Guide | 6.0 wLSN Devices 6.2 wLSN Hub (ISW-BHB1-WY) The wLSN Hub monitors and coordinates two-way communications between the control panel and the detectors. Rotary switches (S1, S2, and S3) configure device operation and enable special diagnostic modes. An LED on the front provides device status. Table 6: wLSN Hub Specifications Wire Gauge Power/Voltage Wire Length Current Draw Wall and Cover Tamper Switch 0.14 (24 AWG) to 1.5 mm (18 AWG). 12 VDC nominal, 7 to 14 VDC ≤300 m (1000 ft) maximum 60 mA Transmits a tamper signal when the detector is removed from its base or pulled away from the wall. For more information on wire distance and the number of devices, refer to the control panel’s documentation. 24 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.2.1 wLSN Hub Switches Use Switches S1, S2, and S3 located on the wLSN Hub’s inner cover to configure the device’s operation or to enable special diagnostic or installation modes. Figure 9: Switches S1 S2 S3 Assign a different address to each option bus device. wLSN Hub choices are S1=1 and S1=2. Switch 1 (S1) configures the wLSN Hub’s address on the option bus. To configure the switches for normal operation, set S1 to 1 or 2. Set Switch 2 (S2) and Switch 3 (S3) to 0 (zero). Bosch Security Systems, Inc. | 12/07 | F01U066216-03 25 wLSN | Reference Guide | 6.0 wLSN Devices 6.2.2 wLSN Hub LED The green LED shows the device’s status during power up, self test, network configuration, and normal operation (Table 7). Figure 10: wLSN Hub LED 1 - LED Table 7: wLSN Hub LED Displays Operation Self Test and Hardware Failure Standard Operation Configuring Network RFSS Mode (Refer to Section 3.0 RFSS Mode on page 7 for more details) 26 LED (Device Status) LED flashes twice per sec. This indicates failure. The wLSN Hub does not operate. LED on LED flashes once every 2 sec. LED flashes once every 4 sec. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.3 wLSN PIR and Dual Motion Detectors (ISW-BPR1-W13PY, ISW-BPR1-W13PGY) The PIR Motion Detector (ISW-BPR1-W13PY) uses an infrared sensor. The Dual Motion Detector uses (ISW-BPR1-W13PGY) both PIR and microwave technology. A cover-and-wall tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. An LED provides status for Walk Test, RFSS, and Discovery Modes. Table 8: wLSN PIR and Dual Motion Detectors Specifications PIR Motion Detector Power/Voltage Dual Motion Detector Power/Voltage Mounting Height 6.3.1 Four AA 1.5 V alkaline batteries Six AA 1.5 V alkaline batteries 2.3 m to 2.7 m (7.5 ft to 9.0 ft) Sensitivity Settings Sensitivity settings are set at the control panel. Refer to the control panel’s documentation for detailed information. Standard Sensitivity (Default Setting) Use this setting when pets are present in the area to be monitored. Standard sensitivity provides excellent detection performance and is the least sensitive to false alarms. Intermediate Sensitivity Only use this setting in non-pet installations where environmental disturbances are minimal. Intermediate sensitivity provides the highest level of detection performance. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 27 wLSN | Reference Guide | 6.0 wLSN Devices Setting the Dual Motion Detector’s Microwave Range Adjustment The Dual Motion Detector’s microwave motion sensor is factory adjusted to sense motion to at least 11 m (35 ft). 1. If the microwave coverage needs adjustment (red or yellow LED does not light), increase or decrease the microwave range as needed (Figure 11). 2. Repeat the Walk Test (Section 6.3.2 Walk Testing on page 29). 3. Repeat Steps 1 and 2 until the required coverage is met. Figure 11: Decreasing and Increasing Microwave Range 28 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.3.2 Walk Testing To maximize battery life, the LED elements do not activate unless the unit is in the Walk Test mode. Perform a Walk Test to determine the boundaries of the coverage area. Walk Test mode can be started from the: • • Control Panel: Enter the appropriate command sequence at the control panel to start the Walk Test mode (refer to the control panel’s documentation). Detector: Slide open and then close the detector cover to start a 90-sec Walk Test mode. Walk Test mode is now active. Motion detected within the detector’s coverage area activates the red LED, sends a signal to the control panel, and restarts a 90-sec timer. If there is no motion for 90 sec, the red LED flashes for the last 10 sec to indicate Walk Test mode is ending. Motion detected restarts the 90-second timer. 1. Start at the pattern’s expected boundary and walk across the pattern moving closer to the detector at each pass while observing the LED (Figure 12). Refer to Table 9 on page 30 for LED indications. Figure 12: Walk Test During Walk Test mode for the wLSN Dual Motion Detector, a motion alarm signal is sent to the control panel only when the red LED flashes (Table 9). It is normal to see a brief green or yellow flash before a red alarm indication when walk testing the Dual Motion Detector. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 29 wLSN | Reference Guide | 6.0 wLSN Devices Table 9: Detector PIR PIR Walk Test LED Indications LED Color Red – fast flash Red – lights for 4 sec Function Power-up (Walk Test disabled) Alarm, motion detected Table 10: Dual Walk Test LED Indications Detector Dual LED Color Green to red – fast flash Green – lights for 3 sec Yellow – lights for 3 sec Function Power-up (Walk Test disabled) Motion detected by PIR Motion detected by microwave Refer to Setting the Dual Motion Detector’s Microwave Range Adjustment on page 28 for more Red – lights for 4 sec information. Alarm, motion detected by both PIR and microwave 2. Walk test from the opposite direction to determine the coverage pattern boundaries from both sides. 3. When walk testing is complete: 30 From the control panel, enter the appropriate command sequence at the control panel to turn off Walk Test mode. At the detector, the detector returns to normal operation after 90 sec of inactivity. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.4 wLSN Door-Window Contact (ISW-BMC1-S135Y) The wLSN Door-Window Contact is a magnetic reed switch and wireless transceiver used for monitoring doors, windows, and other dry contact devices. A cover-and-wall tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. An LED provides status for RFSS and Discovery Modes. Table 11: wLSN Door-Window Contact Specifications Maximum Distance Between Sensor and Magnet Wire Gauge Power/Voltage Terminal Block ≤12,7 mm (1/2 in.), the magnet can be placed on either side. The base is marked to indicate the magnet position. 0.14 mm (22 AWG) to 1.5 mm (16 AWG) Two AA batteries, 1.5 V alkaline For connecting other dry contact devices such as another magnetic reed switch. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 31 wLSN | Reference Guide | 6.0 wLSN Devices 6.4.1 Supported Wiring Configurations For all wiring options, refer to your control panel’s documentation to identify the compatible end-of-line (EOL) resistor options. Single 1 kΩ, 2.2 kΩ, or 3.65 kΩ EOL Resistor Option Refer to Figure 13. Use any number of normally-closed (NC) contacts in series with the loop. Use any number of normally-open (NO) contacts across the loop. Figure 13: Single 1 kΩ, 2.2 kΩ, or 3.65 kΩ EOL Resistor Option 1 - NO 2 - NC 3- 1 kΩ, 2.2 kW, or 3.65 kΩ EOL resistor 32 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 2.2 kΩ Alarm Resistor and Tamper Option Refer to Figure 14. Place up to five normally-closed contacts in series with the 2.2 kΩ resistor. Each contact has either a 1.5 kΩ or 2.2 kΩ resistor across it. No contacts can be used across the loop. The zone recognizes that one or more of the contacts is opened, but not which ones or how many. Figure 14: 2.2 kΩ Alarm Resistor and Tamper Option 1234- 1.5 kΩ, or 2.2 kΩ 1.5 kΩ or 2.2 kΩ (optional, up to 4) 2.2 kΩ EOL resistor NC tamper switch (optional) Bosch Security Systems, Inc. | 12/07 | F01U066216-03 33 wLSN | Reference Guide | 6.0 wLSN Devices 6.5 wLSN Recessed Door-Window Contact (ISW-BMC1-R135Y) The wLSN Recessed Door-Window Contact is a wireless transceiver used for monitoring doors and windows. A cover tamper switch transmits a tamper signal when the cover is removed from its base. An LED provides status for RFSS and Discovery Modes. Table 12: Recessed DW Contact Specifications and Required Tools Power/Voltage Maximum Distance Between Reed Switch and Magnet Drill Tools Circuit Board Removal One CR2 lithium battery, 3 VDC ≤12,7 mm (1/2 in.) Requires the use of a 19 mm (3/4 in.) drill bit and 22 mm (7/8 in.) spade bit Needle nose pliers are recommended Mounting the wLSN Recessed DW Contact in a metal door or window frame could degrade the RF signal strength. 34 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices Figure 15: Recessed Door-Window Contact 1 - Mounting slots for printed circuit board 2- Tamper switch 3 - LED for RFSS Mode and Discovery Mode Bosch Security Systems, Inc. | 12/07 | F01U066216-03 35 wLSN | Reference Guide | 6.0 wLSN Devices 6.6 wLSN Mini Door-Window Contact (ISW-BMC1-M82Y) Similar to the wLSN Door-Window Contact, the wLSN Mini DoorWindow Contact is a wireless transceiver device used for monitoring doors and windows. A cover-and-wall tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. An LED provides status for RFSS, and Discovery Modes. Table 13: wLSN Mini DW Contact Specifications Power/Voltage Maximum Distance Between Reed Switch and Magnet One CR2 lithium battery, 3 VDC ≤12,7 mm (1/2 in.) The magnet can be placed on either side of the detector. Figure 16: Mini Door-Window Contact Tamper Switch (-) (+) 1 - Battery polarity 2- Tamper switch 36 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.7 wLSN Inertia Detector (ISW-BIN1-S135Y) The wLSN Inertia Detector is a vibration detector combined with a wireless transceiver used for monitoring doors or windows. A cover-and-wall tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. An LED provides status for Test, RFSS, and Discovery Modes. Table 14: Inertia Detector Specifications Maximum Distance Between Detector and Magnet Power/Voltage ≤12,7 mm (1/2 in.) The magnet can be placed on either side of the detector. 2 AA batteries, 1.5 V alkaline Bosch Security Systems, Inc. | 12/07 | F01U066216-03 37 wLSN | Reference Guide | 6.0 wLSN Devices Sensor element orientation is critical to the proper operation of the device. The arrow, embossed on the body of this sensor, must always point up. Refer to Figure 17. Figure 17: Sensor Adjustment 90 1 - Remove sensor element 2 - Turn sensor element as desired 3 - Ensure arrow on sensor element points up Route the wiring from the sensor element so it does not make contact with the tamper spring. Refer to Figure 18. Figure 18: Wiring Route 38 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.7.1 Sensitivity Settings All sensitivity settings are programmed at the control panel (refer to your control panel’s documentation for more information). The sensor element has two types of detection: • • Gross Attack Minor Attack Gross Attack is always enabled. The Minor Attack setting is very sensitive and can be disabled. Gross Attack Sensitivity The Gross Attack setting measures vibration activity for a specified length of time. There are four settings: • • • • Low (default) Low to Medium Medium to high High The settings determine the length of time vibration activity is measured. Minor Attack Programming at the control panel determines how many repetitive taps (single vibrations) detected by the sensor indicate a minor attack. By default, Minor Attack is disabled. If enabled, there are two settings: • • Four Taps Eight Taps When a tap occurs, a 90-sec timer starts. If the tap count exceeds the four or eight count threshold within 90 sec, an alarm is transmitted. A single tap such as a branch in the wind lightly brushing a window can start the minor attack timer and tap count. To avoid false alarms, do not use the Minor Attack setting where there is potential for stray vibrations. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 39 wLSN | Reference Guide | 6.0 wLSN Devices 6.7.2 Test Mode The unit is automatically in Test mode for the first 10 minutes after power up. The green LED flashes: • • • 40 Once to indicate initialization is complete and the unit is in Test mode Twice to indicate a Minor Attack activation Three times to indicate a Gross Attack activation Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.8 wLSN Key Fob (ISW-BKF1-H5Y) The wLSN Key Fob is a two-way personal transceiver carried by the user. Use it to remotely arm or disarm a security area. Features include: • • Five buttons: Two buttons are for arming and disarming. Two buttons can be programmed at the control panel to control lights, garage doors, and so on. To operate the intended output, press and hold the appropriate button for at least one sec. Two LEDs: One LED indicates status and the other is suitable for use as a flashlight. Figure 19: Key Fob Buttons and LEDs 12345- High intensity LED and button Status LED Disarm button Arm button Programmable buttons Bosch Security Systems, Inc. | 12/07 | F01U066216-03 41 wLSN | Reference Guide | 6.0 wLSN Devices Table 15: wLSN Key Fob Specifications Power/Voltage Gaskets 6.8.1 Two CR2032 lithium batteries, 3 VDC Interchangeable; for multiple users, different colors available Key Fob Buttons Refer to your control panel’s documentation to program the functions of the programmable buttons. Pressing any button causes the status LED to flash alternately red and green for about 15 sec. This indicates that commands were sent to the control panel. Pressing and holding both the arm and disarm buttons together for 1 sec transmits a panic signal to the control panel. 6.8.2 LED A flashing red status LED during key fob inactivity is an indication to replace the batteries. For specific information regarding the various LED states, refer to your control panel’s documentation. 42 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.9 wLSN Relay Module (ISW-BRL1-WY) The wLSN Relay Module allows the control panel to control external devices through a Form C relay. This module also provides a supervised point for monitoring external devices (refer to Section 6.4.1 Supported Wiring Configurations on page 32). Auxiliary power input terminals are also provided to supplement battery power when relay use is high. A cover-and-wall tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. An LED provides status for RFSS and Discovery Modes. Table 16: Relay Module Specifications Wire Gauge Power Auxiliary Power Input Terminal Blocks Relay Output 0.14 mm (22 AWG) to 1.5 mm (14 AWG) Four AA batteries, 1.5 V alkaline 12 VDC nominal (6 VDC to 14 VDC) 50 mA current draw Compatible with any 12 VDC nominal power supply DC+ and DC – External power source, 12 VDC nominal, 6 VDC to 14 VDC Input, supervised sensor loop PT + and PT – (input) NO, C, NC (output) Relay output for control of external devices. 2A at 30 VDC maximum (resistive load) The external power option is intended to be used as a supplemental (secondary) source of power only. Do not operate the Relay Module without the batteries. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 43 wLSN | Reference Guide | 6.0 wLSN Devices 6.10 wLSN Indoor Siren (ISW-BSR1-WY) The wLSN Indoor Siren provides auxiliary power input terminals are also provided to supplement battery power when siren use is high. A cover-and-wall tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. An LED provides status for RFSS and Discovery Modes. Table 17: Siren Specifications Wire Gauge Power Auxiliary Power Input Terminal Blocks Sounder 0.14 mm (22 AWG) to 1.5 mm (14 AWG). Four AA batteries, 1.5 V alkaline 12 VDC nominal (6 VDC to 14 VDC) 50 mA current draw Compatible with any 12 VDC nominal power supply DC+ and DC – (input) External power source, 12 VDC nominal, 6 VDC to 14 VDC 85 dB at 3 m (10 ft) The external power option is intended to be used as a supplemental (secondary) source of power only. Do not operate the siren without the batteries. 44 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.11 wLSN Smoke and Heat Detector (ISW-BSM1-SY) The wLSN Smoke and Heat Detector provides fixed temperature and rate-of-rise sensors. Under normal conditions, the red LED flashes once every 8 sec while the sensor monitors the surrounding environment. When the sensor detects smoke, the LED changes from flashing to steady and the sounder produces a loud continuous tone. Refer to Table 19 on page 47, and Table 20 on page 48. A self-diagnostic feature monitors detector sensitivity and operational status. A cover tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. The optical chamber is removable for easy maintenance. Table 18: Smoke Detector Specifications Power/Voltage Fixed Temperature Sensor Rate-of-Rise Sensor Photoelectric Beam Obscuration Sensitivity Drift Compensation Adjustment Average Alarm Current Sounder Two lithium batteries; 3 VDC +57° C ± 3° C (+135° F ±5° F) +8.3° C/min>+41° C (+15° F/min>105° F) 0.14 ± 0.04 dB/m 1.64%/m (0.5%/ft) maximum 70 mA 85 dBA at 3 m Bosch Security Systems, Inc. | 12/07 | F01U066216-03 45 wLSN | Reference Guide | 6.0 wLSN Devices Figure 20: wLSN Smoke Detector 12- High intensity LED Test/Silence Button 6.11.1 Battery Replacement Replace batteries when the LED stops flashing and the sounder chirps every 45 sec. The low battery trouble chirps can be silenced for 24 hours by pushing the Test/Silence Button. Refer to Figure 20 on page 46 for the location of the Test/Silence Button. 6.11.2 Smoke Test To avoid a fire department dispatch, contact the central monitoring station or put the control panel into test mode before activating the detector using this method. Test smoke detectors annually using an approved aerosol smoke tester to simulate an alarm. Follow the instructions on the can. The LED should remain on while the detector provides a continuous tone. The detector automatically resets when smoke is no longer present. A detector that fails to activate with the smoke test might require cleaning or replacement. 46 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.11.3 Sensitivity Test Test mode is seen by the control panel as a test. It does not send an alarm. The detector includes a Sensitivity Level Test mode for determining the detector’s sensitivity: 1. Press and hold the Test/Silence button for 4 sec. The LED flashes 1 to 9 times. Refer to Figure 20 on page 46. 2. Count the number of LED flashes and use Table 19 to determine the status of the detector’s sensitivity and the action to take. Table 19: Smoke Detector Sensitivity Conditions Flashes 2 to 3 4 to 7 8 to 9 Action Recommended Self-diagnostics failure. Return device for service or replacement. Device is becoming insensitive. Clean the detector and re-test. If error persists, replace the detector. Detector is within normal sensitivity range. Device is becoming too sensitive. Confirm that the smoke chamber is snapped down securely. Clean the sensor and re-test. 6.11.4 Silencing an Alarm Press the Test/Silence Button (refer to Figure 20 on page 46) to silence the sounder during an alarm. If smoke is still present after a few minutes, the sounder and alarm resume. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 47 wLSN | Reference Guide | 6.0 wLSN Devices 6.11.5 LED Table 20: LED Status LED Flashing On Off Status Flashes every 8 sec under normal operation. Detects smoke, sending an alarm Malfunction, replace the batteries, clean the detector, or replace the optical chamber as required. 6.11.6 Cleaning the Detector and Replacing the Optical Chamber Clean the detector cover with a dry or damp cloth as needed to keep it free from dust and dirt. Clean the detector interior at least once a year, or as needed. To clean the detector: 1. Rotate the detector counter-clockwise to remove it from the mounting base. 2. Remove the batteries. 3. Slide a flat head screwdriver in the slot on the detector cap and gently push down to pry the cap off (Figure 21). Figure 21: Remove the Detector Cap 48 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 4. Squeeze the optical chamber where indicated and pull it up and away from the detector (Figure 22). Figure 22: Remove the Chamber 1 - Smoke Chamber Base 2 - Optical Chamber 3 - Alignment Arrows 5. Use compressed air or a soft-bristled brush to remove dust and dirt from the smoke chamber base. 6. Align the new optical chamber with the base and snap into place. 7. To attach the detector cap, line the cap up with the detector, press the cap onto the detector, and turn the cap clockwise to snap it firmly into place. 8. Observing the proper polarity, install the batteries and the battery cover. If the batteries are not installed, the detector does not properly fit onto the mounting base. 9. Mount the detector onto the mounting base. 10. Test the detector’s sensitivity. Refer to Section 6.11.3 Sensitivity Test on page 47. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 49 wLSN | Reference Guide | 6.0 wLSN Devices 6.11.7 Defaulting the Smoke Detector To default the Smoke Detector: 1. Rotate the detector counter-clockwise to remove it from the mounting base. Figure 23: Remove Smoke Detector from Base 1 - Rotate detector counter-clockwise 2 - Remove detector from mounting base 2. Remove the batteries. 3. Separate the housing cover and base by inserting a flat head screwdriver between the cover and base. Figure 24: Separate Housing Cover and Base 50 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 4. Turn the housing base over and locate the transmitter PCB (printed circuit board). 5. Remove the jumper from the transmitter PCB and reinsert it over both pins. Figure 25: Transmitter PCB and Jumper Pins 1 - Housing base 2 - Transmitter PCB 3 - Jumper plug in normal operating position (plug covers a single pin) 4 - Jumper plug removed from pin 5 - Jumper plug covering both pins 6. Reinsert the batteries. Do not close the housing base. The detector is now defaulted. 7. Remove the jumper and replace it over one pin (normal operating position). 8. Place the housing cover back on the housing base. Align the sounder with the notch on the housing cover and push firmly until the cover and base snap into place. 9. Close the battery case and mount the detector onto its mounting base. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 51 wLSN | Reference Guide | 6.0 wLSN Devices 6.12 wLSN Glass Break Detector (ISW-BGB1-SAY) The wLSN Glass Break Detector is a wireless transmitter used for detecting breaking glass. A cover-and-wall tamper switch transmits a tamper signal when the cover is removed from its base, or when the unit is pulled away from the wall. Table 21: Glass Break Detector Specifications Power/Voltage Accoustic Capabilities 2 AA batteries, 1.5 V alkaline Type Glass types and thicknesses Plate Minimum pane size for all types of glass Range 52 Thickness 0,24 cm to 0,95 cm (0.1 in. to 0.4 in.) 0,32 cm to 0,95 cm Tempered (0.1 in. to 0.4 in.) 0,32 cm to 1,43 cm Laminated* (0.1 in. to 0.6 in.) Wired 0,64 cm (0.25 in.) * Protected only if both panes of glass are broken. 28 cm x 28 cm (11 in. x 11 in.) Maximum 7.6 m (25 ft) No minimum range Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices Figure 26: Glass Break Front Layout 10 EVENT 12345678910 - Service door tamper switch AA batteries Service door Test Mode pads Sensitivity DIP switches Event LED Alarm LED LED enable switch (off position) Housing screw RFSS Mode LED (remove housing screw and cover piece) Bosch Security Systems, Inc. | 12/07 | F01U066216-03 53 wLSN | Reference Guide | 6.0 wLSN Devices 6.12.1 Installation Considerations Glass break detectors are intended only as a component of a perimeter protection system. You should always use a motion detector in conjunction with a glass break detector. For the best detector performance, select a mounting location that is: • • • • • • within 7.6 m (25 ft) of the protected glass. within clear view of the protected glass. at least 2 m (6.5 ft) from the floor. at least 1 m (3 ft) from forced-air ducts. at least 1 m (3 ft) from sirens or bells greater than 5 cm (2 in.) in diameter. on a window frame if any heavy window covering is present. Avoid mounting the detector: • • • • 54 in a corner. on the same wall as the protected glass. on free-standing posts or pillars. in rooms with noisy equipment such as air compressors, bells, and power tools. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.12.2 Sensitivity Settings 1. If the front housing is attached, carefully open the service door (Item 3, Figure 26). 2. Enable the LEDs for test purposes by sliding the LED ENABLE switch (Item 8, Figure 26) in the direction the arrow points (above the switch). An orange flag protrudes from the side of the detector. Figure 27: Glass Break Sensitivity Switches EVENT 12- Test pads Sensitivity switches 3. Determine the sensitivity setting for your application from Table 22. Table 22: Glass Break Sensitivity Settings Sensitivity Maximum Medium Low Lowest SENS1 OFF ON OFF ON SENS2 OFF OFF ON ON Approximate Range 7,6 m (25 ft) 4,6 m (15 ft) 3 m (10 ft) 1,5 m (5 ft) 4. Use a small screwdriver to move the sensitivity switches. Use the settings determined in Step 3. 5. Turn on any sources of noise (such as machinery, office, or audio equipment) in the area. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 55 wLSN | Reference Guide | 6.0 wLSN Devices 6. Observe the green event LED (Item 6, Figure 26 on page 53) for approximately 1 min. If the green LED flashes, relocate the unit or reduce the sensitivity by adjusting the sensitivity switch. 7. Repeat Steps 3 through 6 until you achieve the best sensitivity level. 8. After setting the sensitivity, slide the LED enable switch (Item 8, Figure 26 on page 53) to the OFF position. 6.12.3 Testing Test the detector at least once each year. Test the detector with the 13-332 Sound Sensor Tester. Figure 28: 13-332 Sound Sensor Tester ACTIVATE TEST FLEX MAN 13-332 123- 56 Activate/Test switch Start button Flex/Man switch Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices Entering Test Mode Place the detector in Test Mode. In Test Mode, the detector’s LED disable switch (Item 8, Figure 26 on page 53) is overridden. You can enter the Test Mode locally or remotely. To enter the Test Mode locally: 1. Carefully open the service door of the detector. 2. Insert a screwdriver into the slot next to the sensitivity switches that contains the test pads (Item 1, Figure 27 on page 55). 3. Momentarily short both test pads together with the tip of the screwdriver, or other metallic conductive object. The Event LED (green) (Item 6, Figure 26 on page 53) flashes once per sec. If the green LED does not flash, repeat Steps 2 and 3. The 13-332 Sound Sensor Tester produces extremely loud sounds and can be hazardous to hearing when used at close range. Do not point the 13-332 towards someone’s head. To enter the Test Mode remotely: 1. Stand within 3 m (10 ft) of the detector. 2. Move the switches on top of the 13-332 Tester to ACTIVATE and to MAN modes (Items 1 and 3, Figure 28 on page 56). 3. Point the front of the tester towards the detector and press the red Start button on top (Item 2, Figure 28 on page 56). The tester buzzes and the green LED on the detector flashes once per sec. If the green LED does not flash, move closer to the detector and repeat the procedure. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 57 wLSN | Reference Guide | 6.0 wLSN Devices Testing the Detector (Flex and Audio Signals) 1. Set the 13-332 Tester switches to the TEST and FLEX positions (Items 1 and 3, Figure 28 on page 56). 2. Press the red Start button (Item 2, Figure 28 on page 56). The tester activates and starts an eight-sec armed period. 3. If window coverings are present, close them fully. 4. Hold the 13-332 Tester near the point on the glass farthest from the detector. If window coverings are present, hold the tester between the glass and window coverings. 5. Carefully strike the glass with a cushioned tool. The 13-332 Tester responds by producing a burst of glass break audio. If the detector receives both the flex and audio signals properly, its red Alarm LED lights for 3 sec. If the red LED does not light, return to Section 3.0 RFSS Site Evaluation on page 7 to reposition the detector. Exiting Test Mode To exit the Test Mode locally: 1. Carefully open the service door of the detector. 2. Insert a screwdriver into the slot next to the sensitivity switches that contains the test pads (Item 1, Figure 27 on page 55). 3. Momentarily short both test pads together with the tip of the screwdriver, or other metallic conductive object. When the detector exits Test Mode, the green Event LED (Item 6, Figure 26 on page 53) stops flashing. If the Event LED continues to flash, repeat Steps 2 and 3. To exit the Test Mode remotely: 1. Stand within 3 m (10 ft) of the detector. 2. Move the switches on top of the 13-332 Tester to ACTIVATE and to MAN modes (Items 1 and 3, Figure 28 on page 56). 3. Point the front of the tester towards the detector and press the red Start button on top (Item 2, Figure 28 on page 56). The tester buzzes. 58 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | 6.0 wLSN Devices 6.12.4 Low Battery Indication The detector indicates a low battery condition in two ways: • • If the LEDs are enabled, both flash simultaneously every sec. A low battery status indication is sent to the control panel. The LED flashing and a low battery indication at the control panel are independent of each other and do not necessarily occur at the same time. Receiving either condition indicates a low battery. 6.12.5 Wall Tamper Tab Entering RFSS Mode To enter RFSS Mode if the wall tamper tab is removed: 1. Remove and reinsert the batteries. 2. Press and hold the wall tamper switch. Refer to Figure 29. 3. Quickly press and release the cover tamper switch four times within 10 sec of reinserting the batteries. Refer to Figure 29. The detector enters RFSS Mode. Figure 29: Wall and Cover Tamper Switches ID:000000000 RF1100E 12- Wall tamper switch (back of detector) Cover tamper switch (inside of detector) Bosch Security Systems, Inc. | 12/07 | F01U066216-03 59 wLSN | Reference Guide | 6.0 wLSN Devices Defaulting the Glass Break Detector If the wall tamper tab is removed and you must return the default the Glass Break Detector: 1. Remove the batteries from the detector. 2. Place the detector on a flat surface to depress the wall tamper switch. Refer to Figure 29 on page 59. 3. Press and hold the cover tamper switch. Refer to Figure 29 on page 59. 4. While both tamper switches are depressed, reinsert the batteries. The RFSS Mode LED turns on. Refer to Figure 26 on page 53 for the location of the RFSS Mode LED. 5. Release the cover tamper switch within five sec after the RFSS Mode LED turns on. The detector is now defaulted. 60 Bosch Security Systems, Inc. | 12/07 | F01U066216-03 wLSN | Reference Guide | Appendix: Icons and Symbols Appendix: Icons and Symbols Table 23: Icons and Symbols Icon or Symbol Meaning Not Pet Friendly® Pet Friendly (appropriate weights below graphic) ≥45 kg (100 lb) Point away from rotating machines. Point away from objects that rapidly change temperature. Do not mount in sunlight. Do not point toward window. Do not mount outside. Device has a wall or cover tamper. Not pet friendly when lookdown zone is enabled. Bosch Security Systems, Inc. | 12/07 | F01U066216-03 61 Bosch Security Systems, Inc. www.boschsecurity.com © 2007 Bosch Security Systems, Inc. F01U066216-01 F01U066216-03
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2007:12:03 13:46:46-05:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2007:12:03 13:53:36-05:00 Metadata Date : 2007:12:03 13:53:36-05:00 Format : application/pdf Creator : bnt5fp Title : Microsoft Word - F01U066216-03 wLSN Ref Guide_EN915.doc Document ID : uuid:6f4095c4-060d-4138-88d6-e1feefc00882 Instance ID : uuid:5bb830a5-329f-4f81-8118-9c43e7c66567 Page Count : 62 Author : bnt5fpEXIF Metadata provided by EXIF.tools